MONTHYEARML0606705972006-03-24024 March 2006 Notice of Consideration of Proposed Amendment Regarding Contingent Installation of a Temporary Spent Fuel Storage Rack, Proposed No Significant Hazards Consideration Determination, and Opportunity for Hearing/Hybrid Hearing Project stage: Other ML0610900252006-04-17017 April 2006 Draft RAI, Proposed Amendment Re. Spent Fuel Storage Project stage: Draft RAI ML0617401212006-07-0606 July 2006 Request for Withholding Information from Public Disclosure Project stage: Withholding Request Acceptance L-MT-06-058, Response to Request for Additional Information for License Amendment Request for Contingent Installation of Temporary Fuel Storage Rack in Spent Fuel Pool2006-09-0707 September 2006 Response to Request for Additional Information for License Amendment Request for Contingent Installation of Temporary Fuel Storage Rack in Spent Fuel Pool Project stage: Response to RAI ML0633900212006-12-0404 December 2006 Draft RAI Re Proposed Amendment on Contingent Installation of Temporary Spent Fuel Rack Project stage: Draft RAI ML0700500712007-01-0404 January 2007 Request for Conference Call Re. Structural Issues Concerning Temporary Installation of Spent Fuel Rack Project stage: Other ML0706604562007-02-28028 February 2007 Draft SE for Monticello Temporary Spent Fuel Rack Amendment Project stage: Draft Approval ML0707103752007-03-0909 March 2007 Technical Specification Amendment, Revised Section 4.3, Fuel Storage, to Allow Contingent Installation of a Temporary Spent Fuel Storage Rack Project stage: Other ML0705405222007-03-0909 March 2007 License Amendment, Revised Section 4.3, Fuel Storage, of the Technical Specifications to Allow for Contingent Installation of a Temporary Spent Fuel Storage Rack Project stage: Acceptance Review 2006-07-06
[Table View] |
|
---|
Category:E-Mail
MONTHYEARML24022A0212024-01-20020 January 2024 NRR E-mail Capture - Monticello - Request for Additional Information ISI RR-002 Alternative to Use IWB-2500(f) ML23353A0742023-12-19019 December 2023 NRR E-mail Capture - Monticello Nuclear Generating Plant - Acceptance of Proposed Alternative VR-09, Modifications to OMN-17 ML23348A3462023-12-14014 December 2023 NRR E-mail Capture - Monticello Nuclear Generating Plant - Acceptance of License Amendment Request to Revise TS 3.8.6, Battery Parameters, SR 3.8.6.6 ML23268A0292023-09-20020 September 2023 SLRA - Requests for Confirmation of Information - Set 2 - Email from Marieliz Johnson to Shawn Hafen ML23249A2092023-09-0606 September 2023 NRR E-mail Capture - Action: Opportunity to Review and Comment on a New NRC Information Collection, 10 CFR Part 50.55a, Codes and Standards (3150-XXXX) ML23248A3462023-09-0505 September 2023 NRR E-mail Capture - Request for Additional Information for Monticello Nuclear Generating Plant and Prairie Island Nuclear Generating Plant - Decommissioning Funding Status Reports ML23237A4822023-08-25025 August 2023 SLRA - Request for Additional Information - Set 3 - Email from Marieliz Johnson to Shawn Hafen ML23228A1212023-08-16016 August 2023 NRR E-mail Capture - Monticello Nuclear Generating Plant - Acceptance of Alternative Request VR-11 for MO-2397 ML23227A2182023-08-15015 August 2023 NRR E-mail Capture - Monticello Nuclear Generating Plant - Acceptance of Alternative Request RR-002 to Use IWB-2500(f) ML23219A1072023-08-0707 August 2023 SLRA - Requests for Additional Information - Set 2 - Email from Marieliz Johnson to Shawn Hafen ML23200A3502023-07-19019 July 2023 SLRA - Requests for Additional Information - Set 1 - Email from Marieliz Johnson to Christopher Domingos ML23172A1122023-06-21021 June 2023 SLRA - Requests for Confirmation of Information - Set 1 - Email from Marieliz Johnson to Christopher Domingos ML23054A3322023-02-23023 February 2023 NRR E-mail Capture - Monticello Nuclear Generating Plant - Acceptance of Relief Request to Use Later Edition of ASME BPV Code, Section XI, for ISI Program Code of Record ML23053A1362023-02-13013 February 2023 NRR E-mail Capture - Monticello Nuclear Generating Plant - Acceptance of Relief Request to Use Later Edition of ASME BPV Code, Section XI, for Cisi Program ML23017A2222023-01-13013 January 2023 Verbal Authorization of Proposed Alternative PR-08 Regarding Inservice Testing Requirements of Certain High Pressure Coolant Injection System Components (EPID L-2022-LLR-0088) (Email) ML23004A1982023-01-0404 January 2023 NRR E-mail Capture - Draft Request for Additional Information Monticello Nuclear Generating Plant Request Pr 08, HPCI Pump Quarterly Testing ML23012A2102022-07-26026 July 2022 Letter Submitting Monticello Outline Package ML22181A1962022-06-24024 June 2022 NRR E-mail Capture - Draft RAI Monticello Alternative VR-08 ML22175A1602022-06-24024 June 2022 NRR E-mail Capture - RAI Monticello Fuel Oil Storage Tank Inspection ML22131A2652022-05-11011 May 2022 NRR E-mail Capture - Request for Additional Information Xcel Energy Amendment Request to Create a Common Eplan and EOF for Monticello and Prairie Island ML22123A2822022-05-0303 May 2022 NRR E-mail Capture - Request for Additional Information Monticello Alternative VR-10, EFCV Testing Frequency ML22101A0712022-04-11011 April 2022 NRR E-mail Capture - Monticello - Acceptance of Requested Licensing Action License Amendment Request to Revise TS 3.6.1.8 Residual Heat Removal (RHR) Drywell Spray Header and Nozzle Surveillance Frequency ML22089A1302022-03-30030 March 2022 NRR E-mail Capture - Monticello Nuclear Generating Plant - Acceptance of Alternative Related Excess Flow Check Valve Testing Frequency ML22082A1812022-03-23023 March 2022 NRR E-mail Capture - Monticello Nuclear Generating Plant - Acceptance of VR-08 Alternative to Adopt ASME OM Code Case OMN-28 ML22075A2612022-03-16016 March 2022 NRR E-mail Capture - Monticello Nuclear Generating Plant - Acceptance of VR-07 Alternative Related to MOV Testing Per ASME OM Code Case OMN-26 ML22067A2032022-03-0808 March 2022 Audit Plan to Support Review of an Amendment to Transition to Atrium 11 Fuel (Redacted) ML22011A0642022-01-11011 January 2022 NRR E-mail Capture - Monticello Nuclear Generating Plant - Acceptance of Requested Licensing Action License Amendment Request to Support Diesel Generator Fuel Oil Storage Tank Inspection ML22005A3612022-01-0505 January 2022 NRR E-mail Capture - Monticello Nuclear Generating Plant - Acceptance of Requested Relief Request Alternative Related to Pump Vibration Testing Per ASME OM Code Case OMN-22 ML21347A0082021-12-10010 December 2021 NRR E-mail Capture - Monticello and Prairie Island Nuclear Generating Plant, Units 1 and 2 - Acceptance of Requested License Amendment Standard Emergency Plan and Consolidated Emergency Operations Facility ML21330A0382021-11-18018 November 2021 NRR E-mail Capture - Monticello Nuclear Generating Plant - Acceptance of Requested Relief Request Alternative Related RHR and RHRSW Pump Testing ML21286A7882021-10-0606 October 2021 NRR E-mail Capture - Monticello Nuclear Generating Plant - Acceptance of Requested Relief Request Alternative Related to Residual Heat Removal Heat Exchanger Flow Control Valve Stroke Timing ML21256A1892021-09-13013 September 2021 NRR E-mail Capture - Monticello Nuclear Generating Plant - Acceptance of Requested Relief Request Alternative Related to Testing the Control Rod Drive Scram Discharge Header Check Valves ML21256A1862021-09-13013 September 2021 NRR E-mail Capture - Monticello Nuclear Generating Plant - Acceptance of Requested Relief Request Alternative Related to HPCI and RCIC Pump Testing ML21256A1882021-09-13013 September 2021 NRR E-mail Capture - Monticello Nuclear Generating Plant - Acceptance of Requested Relief Request Alternative Related to Vibration Testing Range for the Sblc Pumps ML21253A2002021-09-10010 September 2021 NRR E-mail Capture - Monticello Nuclear Generating Plant - Acceptance of Requested Relief Request Alternative Related to Pressure Isolation Valve Testing ML21252A0132021-08-31031 August 2021 NRR E-mail Capture - Monticello Nuclear Generating Plant - Acceptance of Requested Licensing Action License Amendment Request to Adopt Advanced Framatome Methodologies ML21130A3022021-05-0707 May 2021 Initial and Final Written 10 CFR 21 Notification for GE Hitachi Numac Prnm System ML21110A7042021-04-20020 April 2021 Response: Monticello Nuclear Plant Outage - Covid Risk to On-Site Employees ML21084A2522021-03-24024 March 2021 NRR E-mail Capture - Revised Review Schedule for Monticello TSTF-505 (EPID L-20200LLA-0062) ML21068A2772021-03-0909 March 2021 NRR E-mail Capture - Monticello TSTF-505, Request for Additional Information ML20343A1292020-12-0808 December 2020 NRR E-mail Capture - Request for Additional Information ML20342A1782020-12-0707 December 2020 NRR E-mail Capture - Monticello Nuclear Generating Plant - Acceptance of Requested Licensing Action License Amendment Request to Adopt TSTF-564 Safety Limit MCPR ML20302A1972020-10-26026 October 2020 NRR E-mail Capture - Monticello Request for Additional Information TSTF-505 License Amendment Request ML20289A1072020-10-0606 October 2020 NRR E-mail Capture - Monticello Nuclear Generating Plant - Acceptance of Requested Licensing Action License Amendment Request to Adopt TSTF-582 Reactor Pressure Vessel Water Inventory Control (RPV WIC) Enhancements (EPID L-2020-LLA-0209 ML20191A0252020-07-0101 July 2020 NRR E-mail Capture - Draft Request for Additional Information Monticello Alternative Request RR-016 Related to H8, H9, and H 10 Weld Examinations ML20120A0272020-04-28028 April 2020 NRR E-mail Capture - Request for Additional Information Monticello Long Term Steam Dryer Inspection Plan ML20099F1292020-04-0606 April 2020 E-mail to Licensee for Monticello Lr Phase 4 RFI ML20077L4632020-03-17017 March 2020 NRR E-mail Capture - Monticello Nuclear Generating Plant and Prairie Island Nuclear Generating Plant, Units 1 and 2 -Acceptance of Requested Licensing Action Request to Adopt TSTF-529 ML20064C5352020-03-0404 March 2020 NRR E-mail Capture - Monticello Nuclear Generating Plant - Acceptance of Requested Relief Request Alternative Revise the Previously Authorized Alternative in RR-008 for the H8 and H9 Welds 2024-01-20
[Table view] |
Text
From: Peter Tam To: Loeffler, Rick; Salamon, Gabor Date: 4/17/06 12:30PM
Subject:
Monticello: Draft RAI, Proposed Amendment re. Spent Fuel Storage (TAC MD0302)
Gabe, Rick:
This e-mail conveys our reviewer Yuri Orechwa's draft RAI on your application for amendment regarding contingent installation of the spent fuel rack. Please call me to set up a conference call to discuss these draft questions. The questions pertain only to Section 5.3 (Thermal-Hydraulic Considerations) and Section 5.5 (Criticality of the Monticello Nuclear Generating Plant).
(1) Are there any limitations on the use of the PaR fuel rack in your LAR (i.e. only during a FCOL, by burnup, etc.)? Please state the limiting conditions explicitly.
(2) Please compare in table form, with an attendant discussion, the current SFP licensing basis analysis to the supporting analysis of the SFP with the installation of the additional 8X8 high-density spent fuel storage rack. The information should include, but not be limited to, number of fuel assemblies and their distribution, the distribution of heat load, type of calculation, method of calculation of peak and average values, bulk temperature, clad temperature, Boral temperature, time-to-boiling, etc.
(3) Please compare in table form, with an attendant discussion, the current SFP licensing basis analysis to the supporting analysis of the SFP with the installation of the additional 8X8 high-density spent fuel storage rack. The information should include but not be limited to:
number of fuel assemblies and their distribution, the distribution of burnup and enrichment, type of neutronic calculation to determine keff, (i.e. codes, cross sections, validation, etc.) estimation of uncertainty, maximum worth of the installed and fueled 8X8 high-density storage rack, etc.
This e-mail aims solely to prepare you and others for the proposed conference call. It does not formally convey an NRC staff position, nor does it formally request for additional information. Disposition of the above questions will be discussed in the proposed conference call.
Peter S. Tam, Senior Project Manager Plant Licensing Branch III-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation e-mail: pst@nrc.gov Tel.: 301-415-1451
CC: Akstulewicz, Frank; Orechwa, Yuri Mail Envelope Properties (4443C2A3.544 : 12 : 35330)
Subject:
Monticello: Draft RAI, Proposed Amendment re. Spent Fuel Storage (TAC MD0302)
Creation Date: 4/17/06 12:30PM From: Peter Tam Created By: PST@nrc.gov Recipients Action Date & Time nmcco.com Transferred 04/17/06 12:31 PM Gabor.Salamon (Gabor Salamon)
Richard.Loeffler (Rick Loeffler) nrc.gov OWGWPO01.HQGWDO01 Delivered 04/17/06 12:30 PM FMA CC (Frank Akstulewicz) Opened 04/17/06 2:00 PM nrc.gov TWGWPO01.HQGWDO01 Delivered 04/17/06 12:30 PM YXO CC (Yuri Orechwa) Opened 04/17/06 12:31 PM Post Office Delivered Route nmcco.com OWGWPO01.HQGWDO01 04/17/06 12:30 PM nrc.gov TWGWPO01.HQGWDO01 04/17/06 12:30 PM nrc.gov Files Size Date & Time MESSAGE 3054 04/17/06 12:30PM Options Auto Delete: No Expiration Date: None Notify Recipients: Yes Priority: Standard Reply Requested: No Return Notification: None Concealed
Subject:
No Security: Standard To Be Delivered: Immediate Status Tracking: Delivered & Opened