Analytical Results for Four Water Samples from the Vicinity of the Braidwood Nuclear Generating Station, Braidwood, Illinois (Inspection Report No. 050-00456/06-008)(RFTA No.06-001)
ML061080348
Person / Time
Site: Braidwood Constellation icon.png
Issue date: 04/13/2006
From: Condra D
Oak Ridge Institute for Science & Education
To: Snell W
NRC/RGN-III/DNMS/DB
References
FOIA/PA-2010-0209, IR-06-008, RFTA 06-001
Download: ML061080348 (7)


Text

OAK RIDGE INSTITUTE FOR SCIENCE AND EDUCATION A p d 13,2006 Mr. William Snell US. Nuclear Regulatory Commission Region 111 2443 Warrenville Road Lisle, IL 60532-4351

SUBJECT:

ANALYTICAL RESULTS FOR FOUR WATER SAMPLES FROM THE VICINITY OF THE BRAIDWOOD NUCLEAR GENERATING STATION, BRAIDWOOD, ILLINOIS

[INSPECTION REPORT NO. 050-456/06-0081 (RFTA NO.06-001)

Dear Mr. Snek The Oak Ridge Institute for Science and Education (ORISE) received an electronic mail on March 23,200G requesting total radiostrontium (Sr) and iron-55 (Fe-55) analysis on four of the ten water samples received on December 30,2005 from the vicinity of the Braidwood Generating Station. On March 24,2006 during a phone call to ORISE, the request was expanded to include Americium-241 (Am-241), Plutonim-238,239/240 (Pu-238,239/240),

and nickel-63 (Ni-63). The ten water samples were originally analyzed by gamma spectroscopy for gamma emitting radionuclides and by liquid scintillation for tritium. The letter report for the original analyses was submitted to John House on January 13,2006. Total radiostrontium was analyzed by low background beta counting (Procedures AP4, Revision 13; CP3, Revision 2). Fe-55 and Ni-63 were analyzed by liquid scindation analysis (Procedures AP13, Revision 4; AP12, Revision 4; and CP4, Revision 3). Am and Pu were analyzed by alpha spectroscopy (AS)

(Trocedures API 1, Revision 3; CP2, Revision 12). The sample identifications and collection data are presented in Table 1. ?he AS, Fe, Ni, and Sr data are presented in Tables 2 through 5, respectively.

Samples 1682WOO67 and 1682WOO69 are from the same sample collection site but were collected on different days. An aliquot of 1682W0067 was used in the Sr analysis, but subsequently the rest of the sample was cross contaminated with another sample. Aliquots from 1682W0069 were used in the AS, Fe, and Ni analyses.

ORISE's Quality Control (QC) requirements were met for these analyses. The QC files are available for your review upon request RECEIVED APR 1 8 2006

Mr. William Snell April 13,2006 Distribution approval and concurrence :

Qualin. Xlanager Technical Managemenr l'eam Member My contact information is listed below. You may also contact Wade Ivey at 865.576.9184 with any questions or comments.

Sincerelv.

Initials

--\\<-

7 Dale Condra, Manager Laboratory RDC:WPI:ar c:

T. McLaughh, NRC/NMSS/TWFN 7F27 E. Abelquist, ORISE E. Knox-Davin, NRC/NMSS/TWFN 8A23 G. Bonano, NRC Region I11 S. Kirk, ORISE File 1682 Voice: 865.241.3242 Fax: 865.241.3248 E-mail: CondraD@orau.gov

TABLE 1 ORISE Sample ID SAMPLE IDENTIFICATIONS AND COLLECTION DATA BRAIDWOOD NUCLEAR GENERATING STATION BRAIDWOOD, ILLINOIS NRC Region 111 Sample ID 1682W0064 1682W0065 1682W0066 1682W0067b 1 682W0069bd Time na na NRC-64-R3 NRC-65-R3 NRC-66-R3 NRC-67-R3 NRC-69-R3 Rrvdwood Nuclcv Gcncnhng Stahon 1682\\Data Tables\\Z006-04-13 Data Tables Spccial Analyticd Request 16RZ

TABLE 2 ORISE Sample ID CONCENTRATIONS OF AMERICIUM-241 AND PLUTONIUM-238,239/240 I N WATER SAMPLES BY ALPHA SPECTROSCOPY AP11, REVISION 3; CP2, REVISION 12 BRAIDWOOD NUCLEAR GENERATING STATION BRAIDWOOD, ILLINOIS Radionuclide Concentrations' (pCi/L)

NRC Region 111 Sample ID Am-241 Pu-238 Pu-239/240 1682W0064 NRC-64-R3

-0.10 f 0.15 i 0.80 0.15 ? 0.30 1682W0065 NRC-65-R3

-1.0 f 1.1 0.15 ? 0.55 0.22 i 0.26 1682WOO66 NRC-66-R3 0.7

_+

1.1

-0.21 f 0.69 0.28 i 0.34 1682W0069 NRC-69-R3 0.23 k 0.95 0.07 ir 0.58 0.00' f 0.28

TABLE 3 ORISE Sample NRC Region 111 Fe-55 Concentrations, TPUs, and ID Sample ID MDCS @Ci/L) 1682W0064 NRC-64-R3 8

5Zb (88) 1682W0065 NRC-65-R3 22 f

52 (88) 1682W0069 NRC-69-R3

-9 2

52 (88) 1682W0066 NRC-66-R3 16 52 (88)

Braidwood Nuclcar Generating Stidon 1682\\Data libles\\ZM6-04-13 Data Tables Special Analytical Requcst 16H2

TABLE 4 ORISE Sample ID NRC Region 111 Ni-63 Concenuations, TPUs, and Sample ID MDCS' @Ci/L)

'MDCs are in parcnthasir.

blJncermintics rcvrescnt the 95O% confidence level, based on toed propagated uncmainties.

Hraidwond Nuclcir Generating Stiuon 168Z\\Dara Tabler\\ZW6-0+13 Data Tables Special Analytical Request 1682

TABLE 5 1682WOO64 1682W0065 1682W0066 1682W0067 CONCENTRATIONS OF TOTAL RADIOSTRONTIUM (Sr)

IN WATER SAMPLES BY LOW BACKGROUND BETA COUNTING AP4, REVISION U; CP3, REVISION 2 BRAIDWOOD NUCLEAR GENERATING STATION BRAIDWOOD, ILLINOIS NRC-64-R3 0.5

?

l.lb (1.9)

NRC-65-R3 0.2 1.1 (1.9)

NRC-66-R3 0.8

?

1.2 (2.1)

NRC-67-R3

-0.8

?

1.2 (2.1)

I, II NRC Region I11 St Concentrations, TPUs, and Sample ID MDCS' @Ci/L)

Braidwood Nuclcar Generatiox Station 1682\\l>ata Tables\\2006-0413 Data 'Tables Spccid Analytical Request 1682