Correction to Amendment No. 231
ML061030544
Person / Time
Site: Susquehanna 
(NPF-014)
Issue date: 04/26/2006
From: Richard Guzman
Plant Licensing Branch III-2
To: Mckinney B
Susquehanna
Guzman R, NRR/DLPM 415-1030
References
TAC MC9187
Download: ML061030544 (5)


Text

April 26, 2006 Mr. Britt T. McKinney Sr. Vice President and and Chief Nuclear Officer PPL Susquehanna, LLC 769 Salem Blvd., NUCSB3 Berwick, PA 18603-0467

SUBJECT:

SUSQUEHANNA STEAM ELECTRIC STATION, UNIT 1 - CORRECTION TO AMENDMENT NO. 231 (TAC NO. MC9187)

Dear Mr. McKinney:

On March 20, 2006, the Nuclear Regulatory Commission (NRC) issued Amendment No. 231 to Facility Operating License No. NPF-14 for the Susquehanna Steam Electric Station, Unit 1 (SSES 1). The amendment changed the SSES 1 Technical Specification (TSs) by revising (1) the SSES 1 Cycle 15 (U1C15) Minimum Critical Power Ratio (CPR) Safety Limit (MCPR SL) for single-loop operation and (2) the references listed in Section 5.6.5.b.

On March 21, 2006, Mr. Duane Filchner of your staff indicated that there was an error in Section 3.1 of the safety evaluation (SE) in that paragraph 4 stated, As PPL previously described in its letter dated December 22, 2003 (ML04002030346), changes in both the two-loop and single-loop MCPR safety limits are due solely to cycle-to-cycle variation and estimated to range from... We agree that this is an incorrect statement. The statement should read, As PPL previously described in its letter dated December 22, 2003 (ML04002030346),

changes in both the two-loop and single-loop due solely to cycle-to-cycle variation are estimated to range from... The incorrect statement implies that the changes in the MCPR SL are due to cycle-to-cycle variation, whereas the intent of the statement in your December 22, 2003, submittal was to provide the NRC with an estimated range of change in the MCPR SLs due solely to cycle-to-cycle variation.

In addition, paragraph 2 in Section 3.1 of the NRCs SE, incorrectly references EMF-1997(P)(A) as the applicable SPCB CPR correlation reference for calculating the MCPR SL. The correct reference for the SPCB CPR correlation is EMF-2209(P)(A).

B.T. McKinney Please update your record file to include the above corrections. We apologize if the errors caused you any inconvenience. If there are any questions regarding this matter, please contact me at (301) 415-1030.

Sincerely,

/RA/

Richard V. Guzman, Project Manager Plant Licensing Branch I-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-387 cc: See next page

B.T. McKinney Please update your record file to include the above corrections. We apologize if the errors caused you any inconvenience. If there are any questions regarding this matter, please contact me at (301) 415-1030.

Sincerely,

/RA/

Richard V. Guzman, Project Manager Plant Licensing Branch I-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-387 cc: See next page DISTRIBUTION:

PUBLIC RidsNrrDorlLpla RidsNrrPMRGuzman RidsOGCMailCenter RidsNrrLASLittle THuang LPLI-1 RF RidsAcrsAcnwMailCenter RidsNrrDssSbwb GHill (4)

ACCESSION NO.: ML061030544 OFFICE LPLI-1/PM LPLI-1/LA PDI-1/BC NAME RGuzman SLittle RLaufer DATE 4/26/06 4/26/06 4/26/06 OFFICIAL RECORD COPY

Susquehanna Steam Electric Station, Units 1 and 2 cc:

Robert A. Saccone Vice President - Nuclear Operations PPL Susquehanna, LLC 769 Salem Blvd., NUCSB3 Berwick, PA 18603-0467 Aloysius J. Wrape, III General Manager - Performance Improvement and Oversight PPL Susquehanna, LLC Two North Ninth Street, GENPL4 Allentown, PA 18101-1179 Terry L. Harpster General Manager - Plant Support PPL Susquehanna, LLC 769 Salem Blvd., NUCSA4 Berwick, PA 18603-0467 Rocco R. Sgarro Manager - Nuclear Regulatory Affairs PPL Susquehanna, LLC Two North Ninth Street, GENPL4 Allentown, PA 18101-1179 Walter E. Morrissey Supervising Engineer Nuclear Regulatory Affairs PPL Susquehanna, LLC 769 Salem Blvd., NUCSA4 Berwick, PA 18603-0467 Michael H. Crowthers Supervising Engineer Nuclear Regulatory Affairs PPL Susquehanna, LLC Two North Ninth Street, GENPL4 Allentown, PA 18101-1179 Steven M. Cook Manager - Quality Assurance PPL Susquehanna, LLC 769 Salem Blvd., NUCSB2 Berwick, PA 18603-0467 Luis A. Ramos Community Relations Manager, Susquehanna PPL Susquehanna, LLC 634 Salem Blvd., SSO Berwick, PA 18603-0467 Bryan A. Snapp, Esq Assoc. General Counsel PPL Services Corporation Two North Ninth Street, GENTW3 Allentown, PA 18101-1179 Supervisor - Document Control Services PPL Susquehanna, LLC Two North Ninth Street, GENPL4 Allentown, PA 18101-1179 Richard W. Osborne Allegheny Electric Cooperative, Inc.

212 Locust Street P.O. Box 1266 Harrisburg, PA 17108-1266 Director, Bureau of Radiation Protection Pennsylvania Department of Environmental Protection Rachel Carson State Office Building P.O. Box 8469 Harrisburg, PA 17105-8469 Senior Resident Inspector U.S. Nuclear Regulatory Commission P.O. Box 35, NUCSA4 Berwick, PA 18603-0035 Regional Administrator, Region 1 U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 Board of Supervisors Salem Township P.O. Box 405 Berwick, PA 18603-0035

Susquehanna Steam Electric Station, Units 1 and 2 cc:

Dr. Judith Johnsrud National Energy Committee Sierra Club 443 Orlando Avenue State College, PA 16803