April 14, 2006 Mr. Randall K. Edington Vice President-Nuclear and CNO Nebraska Public Power District P. O. Box 98 Brownville, NE 68321
SUBJECT:
COOPER NUCLEAR STATION - REQUEST FOR ADDITIONAL INFORMATION RE: RELIEF REQUEST RI-05 FOR THE FOURTH 10-YEAR INSERVICE INSPECTION INTERVAL (TAC NO. MD0280)
Dear Mr. Edington:
The Nuclear Regulatory Commission (NRC) staff has reviewed the information provided in the February 23, 2006, submittal and has determined that the additional information identified in this enclosure is required in order for the NRC staff to complete its review. The licensee requested NRC staff approval of the subject relief request by September 1, 2006. To meet internal scheduling dates, the NRC staff requests that the licensee provide its response no later than May 5, 2006.
Sincerely,
/RA/
Brian Benney, Project Manager Plant Licensing Branch IV Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-298
Enclosure:
Request for Additional Information cc w/encl: See next page
April 14, 2006 Mr. Randall K. Edington Vice President-Nuclear and CNO Nebraska Public Power District P. O. Box 98 Brownville, NE 68321
SUBJECT:
COOPER NUCLEAR STATION - REQUEST FOR ADDITIONAL INFORMATION RE: RELIEF REQUEST RI-05 FOR THE FOURTH 10-YEAR INSERVICE INSPECTION INTERVAL (TAC NO. MD0280)
Dear Mr. Edington:
The Nuclear Regulatory Commission (NRC) staff has reviewed the information provided in the February 23, 2006, submittal and has determined that the additional information identified in this enclosure is required in order for the NRC staff to complete its review. The licensee requested NRC staff approval of the subject relief request by September 1, 2006. To meet internal scheduling dates, the NRC staff requests that the licensee provide its response no later than May 5, 2006.
Sincerely,
/RA/
Brian Benney, Project Manager Plant Licensing Branch IV Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-298
Enclosure:
Request for Additional Information cc w/encl: See next page DISTRIBUTION:
PUBLIC RidsNrrDorl (CHaney/CHolden)
LPLIV r/f RidsRgn4MailCenter (KKennedy)
RidsNrrLALFeizollahi RidsNrrDorlDpr RidsNrrPMBBenney RidsOgcRp RidsNrrDorlLpl4 (DTerao)
RidsAcrsAcnwMailCenter ADAMS ACCESSION NO:
NRR-088 OFFICE LPL4/PM LPL4/LA LPL4/BC NAME BBenney LFeizollahi DTerao DATE 4/14/06 4/13/06 4/14/06 OFFICIAL RECORD COPY
REQUEST FOR ADDITIONAL INFORMATION BY THE OFFICE OF NUCLEAR REACTOR REGULATION RELIEF REQUEST RI-05 FOR THE FOURTH 10-YEAR INSERVICE INSPECTION INTERVAL FACILITY OPERATING LICENSE NO. DPR-46 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION DOCKET NO. 50-298 By letter dated February 23, 2006, Nebraska Public Power District (NPPD), the licensee for Cooper Nuclear Station (CNS), submitted a request for relief for U.S. Nuclear Regulatory Commission (NRC) review and approval to address the requirements of American Society of Mechanical Engineers Boiler and Pressure Vessel Code (ASME Code),Section XI, Table IWC-2500-1, Examination Category C-A, Item Number C1.10. Relief Request RI-05 asserts that compliance with the examination requirements is impractical because the geometry of the subject residual heat removal (RHR) heat exchanger shell welds prevents a meaningful ultrasonic examination from being performed on the welds. In the relief request submittal, NPPD proposed that, as an alternative to the above requirement, a VT-1 visual examination would be performed of the applicable welds each inspection interval. Additionally, a VT-2 visual examination will be performed on the shell side of the RHR heat exchanger in accordance with Table IWC-2500-1, Category C-H.
The NRC staff has reviewed the information the licensee provided that supports the proposed relief request and requires the following information from the licensee to clarify the submittal:
1.
The submittal dated February 23, 2006, stated that [a]s an alternative to the [ASME]
[C]ode-required examination, CNS will perform a visual examination, VT-1, of the applicable welds each inspection interval. Were the VT-1 visual examinations performed in the second and third inservice inspection (ISI) intervals for which this relief has been previously granted, and if so, what were the results of the examinations?
2.
Please describe why the proposed VT-1 examination will continue to provide reasonable assurance of structural integrity through the end of the fourth ISI interval.
February 2006 Cooper Nuclear Station cc:
Mr. William J. Fehrman President and Chief Executive Officer Nebraska Public Power District 1414 15th Street Columbus, NE 68601 Mr. Gene Mace Nuclear Asset Manager Nebraska Public Power District P.O. Box 98 Brownville, NE 68321 Mr. John C. McClure Vice President and General Counsel Nebraska Public Power District P. O. Box 499 Columbus, NE 68602-0499 Mr. Paul V. Fleming Licensing Manager Nebraska Public Power District P.O. Box 98 Brownville, NE 68321 Mr. Michael J. Linder, Director Nebraska Department of Environmental Quality P. O. Box 98922 Lincoln, NE 68509-8922 Chairman Nemaha County Board of Commissioners Nemaha County Courthouse 1824 N Street Auburn, NE 68305 Ms. Julia Schmitt, Manager Radiation Control Program Nebraska Health & Human Services R & L Public Health Assurance 301 Centennial Mall, South P.O. Box 95007 Lincoln, NE 68509-5007 Mr. H. Floyd Gilzow Deputy Director for Policy Missouri Department of Natural Resources P. O. Box 176 Jefferson City, MO 65102-0176 Senior Resident Inspector U.S. Nuclear Regulatory Commission P. O. Box 218 Brownville, NE 68321 Regional Administrator, Region IV U.S. Nuclear Regulatory Commission 611 Ryan Plaza Drive, Suite 400 Arlington, TX 76011 Director, Missouri State Emergency Management Agency P. O. Box 116 Jefferson City, MO 65102-0116 Chief, Radiation and Asbestos Control Section Kansas Department of Health and Environment Bureau of Air and Radiation 1000 SW Jackson Suite 310 Topeka, KS 66612-1366 Mr. Daniel K. McGhee Bureau of Radiological Health Iowa Department of Public Health Lucas State Office Building, 5th Floor 321 East 12th Street Des Moines, IA 50319 Mr. Keith G. Henke, Planner Division of Community and Public Health Office of Emergency Coordination 930 Wildwood P.O. Box 570 Jefferson City, MO 65102 Jerry C. Roberts, Director of Nuclear Safety Assurance Nebraska Public Power District P.O. Box 98 Brownville, NE 68321 Mr. John F. McCann, Director Licensing, Entergy Nuclear Northeast Entergy Nuclear Operations, Inc.