Programs and Manuals 5.5

(

5.0 ADMINISTRATIVE CONTROLS 5.5 Programs and Manuals The following programs shall be established, implemented. and maintained.

5.5.1 Offsite Dose Calculation Manual (ODCM)

a.

The ODCM shall contain the methodology and parameters used in the calculation of offsite doses resulting from radioactive gaseous and liquid effluents. in the calculation of gaseous and liquid effluent monitoring alarm and trip setpoints. and in the conduct of the radiological environmental monitoring program:

b.

The ODCM shall also contain the radioactive effluent controls and radiological environmental monitoring activities. and descriptions of the information that should be included in the Annual Radiological Environmental Operating, and Radioactive Effluent Release Reports required by Specification 5.6.2 and Specification 5.6.3: and

c.

Licensee initiated 'changes to the ODCM:

1.

Shall be documented and records of reviews perforned shall be retained. This documentation shall contain:

i.

sufficient information to support the change(s) together with the appropriate analyses or evaluations justifying the change(s). and ii. a determination that the change(s) maintain the levels of radioactive effluent control.required by 10 CFR 20.1302. 40 CFR 190. 10 CFR 50.36a.

and 10 CFR 50, Appendix I. and not adversely impact the accuracy or reliability of effluent.

dose. or setpoint calculations:

2.

Shall become effective after the approval of the station manager: and BRAIDWOOD - UNITS 1 & 2 5.5 -1

?,,hao Amendment 98

Programs and Manuals 5.5 5.5 Programs and Manuals 5.5.1 Offsite Dose Calculation Manual (ODCM) (continued)

3.

Shall be submitted to the NRC in the form of a complete, legible copy of the entire ODCM as a part of or concurrent with the Radioactive Effluent Release Report for the period of the report in which any change in the ODCM was made.

Each change shall be identified by markings in the margin of the affected pages. clearly indicating the area of the page that was changed, and shall indicate the date (i.e.. month and year) the change was implemented.

5.5.2 Primary Coolant Sources Outside Containment This program provides controls to minimize len:age from those portions of systems outside containment that could contain highly radioactive fluids during a serious transient or accident to levels as low as practicable. The systems include the recirculation portions of the Containment Spray. Safety Injection.

Chemical and Volume Control. and Residual Heat Removal.

The program shall include the following:

a.

Preventive maintenance and periodic visual inspection requirements: and

b.

Integrated leak test requirements for each system at refueling cycle intervals or less.

5.5.3 Deleted.

BRAIDWOOD - UNITS 1 & 2 5.5-2 Amendment 121

 -.I-..-...-..- ---

Programs and Manuals 5.5

(

5.5 Programs and Manuals 5.5.41 Radioactive Effluent Controls Prooram This program conforms to 10 CFR 50.36a for the control of radioactive effluents and for maintaining the doses to members of the public from radioactive effluents as low as reasonably achievable. The program shall be contained in the ODCM, shall be implemented by procedures. and shall include remedial actions to be taken whenever the program limits are exceeded.

The program shall include the following elements:

a.

Limitations on the functional capability of radioactive liquid and gaseous monitoring instrumentation including surveillance tests and setpoint determination in accordance with the methodology in the ODCM;

b.

Limitations on the concentrations of radioactive material released in liquid effluents to unrestricted areas.

conforming to 10 times the concentrations stated in 10 CFR 20. Appendix B. Table 2. Column 2 (to paragraphs 20.1001 -

20.2402):

c.

Monitoring, sampling, and analysis of radioactive liquid and gaseous effluents in accordance with 10 CFR 20.1302 and with

{.

the methodology and parameters in the ODCM:

d.

Limitations on the annual and quarterly doses or dose commitment to a member of the public from radioactive materials in liquid effluents released from each unit to unrestricted areas, conforming to 10 CFR 50, Appendix I:

e.

Determination of cumulative and projected dose contributions from radioactive effluents for the current calendar quarter and current calendar year in accordance with the methodology and parameters in the ODCM at least every 31 days:

(

BRAIDW4OOD - UNITS 1 & 2 55.5 - 3 Amendment 98

Programs and Manuals 5.5

(

5.5 Programs and Manuals 5.5.4 Radioactive Effluent Controls Program (continued)

f.

Limitations on the functional capability and use of the liquid and gaseous effluent treatment systems to ensure that appropriate portions of these systems are used to reduce releases of radioactivity when the projected doses in a period of 31 days would exceed 2% of the guidelines for the annual dose or dose commitment. conforming to 10 CFR 50.

Appendix I;

9.

Limitations on the dose rate resulting from radioactive material released in gaseous effluents to areas beyond the site boundary conforming to the following:

1.

For noble gases:

< a dose-rate of 500 mrem/yr to the whole body and s a dose rate of 3000 mrem/yr to the skin, and

2.

For Iodine-131. Iodine-133. Tritium. and for all radionuclides in particulate form with half lives

> 8 days: s a dose rate of 1500 mrem/yr to any organ;

h.

Limitations on the annual and quarterly air doses resulting from noble gases released in gaseous effluents from each unit to areas beyond the site boundary, conforming to 10 CFR 50. Appendix I:

i.

Limitations on the annual and quarterly doses to a member of the public from Iodine-131. Iodine-133. Tritium. and all radionuclides in particulate form with half lives > 8 days in gaseous effluents released from each unit to areas beyond the site boundary. conforming to 10 CFR 50, Appendix I: and Limitations on the annual dose or dose commitment to any member of the public due to releases of radioactivity' and to radiation from uranium fuel cycle sources, conforming to 40 CFR 190.

5.5.E, ComDonent Cyclic or Transient Limit This program provides controls to track the UFSAR. Section 3.9.

cyclic and transient occurrences to ensure that components are maintained within the design limits.

BRAIDWOOD - UNITS 1 & 2 5.5 -4 Amendment 98

Reporting Requirements 5.6

(

5.6; Reporting Requirements 5.,6.2 Annual Radiological Environmental Operating Report


NOTE---------------

A single submittal may be made for the facility. The submittal should combine sections common to both units.

The Annual Radiological Environmental Operating Report covering the operation of the facility during the previous calendar year shall be submitted by May 15 of each year.

The report shall include sunnaries, interpretations, and analyses of trends of the results of the radiological environmental monitoring program for the reporting period. The material provided shall be consistent with the objectives outlined in the Offsite Dose Calculation Manual (ODCM), and in 10 CFR 50, Appendix I, Sections IV.B.2, IV.B.3, and IV.C.

5.6.3 Radioactive Effluent Release Report


NOTE----

A single submittal may be made for the facility. The submittal

(

-shall combine sections common to both units.

The Radioactive Effluent Release Report covering the operation of the facility during the previous year shall be submitted prior to May 1 of each year in accordance with 10 CFR 50.36a.

The report shall include a summary of the quantities of radioactive liquid and gaseous effluents and solid waste released from the facility.

The material provided shall be consistent with the objectives outlined in the ODCM and Process Control Program and in conformance with 10 CFR 50.36a and 10 CFR Part 50, Appendix ],

Section IV.B.1.