April 10, 2006 LICENSEE:

AmerGen Energy Company, LLC FACILITY:

Oyster Creek Nuclear Generating Station

SUBJECT:

SUMMARY

OF A TELEPHONE CONFERENCE CALL HELD ON FEBRUARY 2, 2006, BETWEEN THE U.S. NUCLEAR REGULATORY COMMISSION AND AMERGEN ENERGY COMPANY, LLC, CONCERNING DRAFT REQUEST FOR ADDITIONAL INFORMATION PERTAINING TO THE OYSTER CREEK NUCLEAR GENERATING STATION, LICENSE RENEWAL APPLICATION The U.S. Nuclear Regulatory Commission staff (NRC or the staff), and representatives of AmerGen Energy Company, LLC (AmerGen), held a telephone conference call on February 2, 2006, to discuss and clarify the staffs draft request for additional information (D-RAI) concerning the Oyster Creek Nuclear Generating Station license renewal application (LRA).

The conference call was useful in clarifying the intent of the staffs D-RAI. provides a listing of the conference call participants. Enclosure 2 contains a listing of the D-RAI discussed with the applicant, including a brief description on the status of the items.

The applicant had an opportunity to comment on this summary.

/RA/

Donnie J. Ashley, Project Manager License Renewal Branch A Division of License Renewal Office of Nuclear Reactor Regulation Docket No. 50-219

Enclosures:

As stated cc w/encls: See next page

DOCUMENT NAME: E:\\Filenet\\ML060590260.wpd OFFICE PM:RLRA LA:DLR BC:RLRA NAME DAshley YEdmonds LLund DATE 04/10/06 02/27/06 02/2706

Oyster Creek Nuclear Generating Station cc:

Site Vice President - Oyster Creek Nuclear Generating Station AmerGen Energy Company, LLC P.O. Box 388 Forked River, NJ 08731 Senior Vice President of Operations AmerGen Energy Company, LLC 200 Exelon Way, KSA 3-N Kennett Square, PA 19348 Kathryn M. Sutton, Esquire Morgan, Lewis, & Bockius LLP 1111 Pennsylvania Avenue, NW Washington, DC 20004 Kent Tosch, Chief New Jersey Department of Environmental Protection Bureau of Nuclear Engineering CN 415 Trenton, NJ 08625 Vice President - Licensing and Regulatory Affairs AmerGen Energy Company, LLC 4300 Winfield Road Warrenville, IL 60555 Regional Administrator, Region I U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406-1415 Mayor of Lacey Township 818 West Lacey Road Forked River, NJ 08731 Senior Resident Inspector U.S. Nuclear Regulatory Commission P.O. Box 445 Forked River, NJ 08731 Director - Licensing and Regulatory Affairs AmerGen Energy Company, LLC Correspondence Control P.O. Box 160 Kennett Square, PA 19348 Manager Licensing - Oyster Creek Exelon Generation Company, LLC Correspondence Control P.O. Box 160 Kennett Square, PA 19348 Regulatory Assurance Manager Oyster Creek AmerGen Energy Company, LLC P.O. Box 388 Forked River, NJ 08731 Assistant General Counsel AmerGen Energy Company, LLC 200 Exelon Way Kennett Square, PA 19348 Ron Bellamy, Region I U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406-1415 Correspondence Control Desk AmerGen Energy Company, LLC 200 Exelon Way, KSA 1--1 Kennett Square, PA 19348 Oyster Creek Nuclear Generating Station Plant Manager AmerGen Energy Company, LLC P.O. Box 388 Forked River, NJ 08731 License Renewal Manager Exelon Generation Company, LLC 200 Exelon Way, Suite 230 Kennett Square, PA 19348

Oyster Creek Nuclear Generating Station cc:

Mr. James Ross Nuclear Energy Institute 1776 I Street, NW, Suite 400 Washington, DC 20006-3708 Mr. Michael P. Gallagher Vice President License Renewal Exelon Generation Company, LLC 200 Exelon Way, Suite 230 Kennett Square, PA 19348 Mr. Christopher M. Crane President and Chief Nuclear Officer AmerGen Energy Company, LLC 4300 Winfield Road Warrenville, IL 60555

Note to: AmerGen Energy Company, LLC, Facility: Oyster Creek Nuclear Generating Station from Donnie Ashley dated April 10, 2006.

SUBJECT:

SUMMARY

OF A TELEPHONE CONFERENCE CALL HELD ON FEBRUARY 2, 2006, BETWEEN THE U.S. NUCLEAR REGULATORY COMMISSION AND AMERGEN ENERGY COMPANY, LLC, CONCERNING DRAFT REQUEST FOR ADDITIONAL INFORMATION PERTAINING TO THE OYSTER CREEK NUCLEAR GENERATING STATION, LICENSE RENEWAL APPLICATION Adams accession no.: ML060590260 DISTRIBUTION:

HARD COPY DLR R/F E-MAIL:

JFair RWeisman AMurphy RPettis GGalletti CLi GBagchi SSmith (srs3)

SDuraiswamy YL (Renee) Li RidsNrrDlr RidsNrrDlrRlra RidsNrrDlrRlrb RidsNrrDe RidsNrrDci RidsNrreEemb RidsNrrDeEeeb RidsNrrDeEqva RidsNrrDss RidsNrrDnrl RidsOgcMailCenter RidsNrrAdes DLR Staff RLaufer GMiller RBellamy, RI RCureton, RI JLilliendahl, RI MModes, RI MSykes, RI AHodgdon RidsOpaMail LIST OF PARTICIPANTS FOR TELEPHONE CONFERENCE CALL TO DISCUSS THE OYSTER CREEK NUCLEAR GENERATING STATION LICENSE RENEWAL APPLICATION February 2, 2006 Participants Affiliations Donnie Ashley U.S. Nuclear Regulatory Commission (NRC)

Vijay Goel NRC Don Warfel AmerGen Energy Company, LLC (AmerGen)

George Beck AmerGen Deb Spamer AmerGen DRAFT REQUESTS FOR ADDITIONAL INFORMATION (D-RAI)

OYSTER CREEK NUCLEAR GENERATING STATION LICENSE RENEWAL APPLICATION February 2, 2006 The U.S. Nuclear Regulatory Commission staff (the staff) and representatives of AmerGen Energy Company, LLC (AmerGen), held a telephone conference call on February 2, 2006, to discuss and clarify the staffs draft request for additional information (D-RAI) concerning the Oyster Creek Nuclear Generating Station, license renewal application (LRA). The following D-RAIs were discussed during the telephone conference call.

D-RAI 2.5.2-1 In Section 2.5.2.2 of the LRA, the applicant identified Phase Bus and Switchyard Bus as electrical component commodity groups which meet the criteria of 10 CFR 54.21(a)(1)(I) and are subject to an aging management review (AMR). However, in Section 2.5.2.3 of the LRA, the Phase Bus and Switchyard Bus commodity groups were eliminated from AMR based on the assertion that none perform a license renewal function. Resolve the conflicting positions in Section 2.5.2.2 and in Section 2.5.2.3 of the LRA, and provide an explanation of why the Phase Bus or Switchyard Bus is not considered to perform any of the license renewal functions listed in 10 CFR 54.4(a), and is not subject to AMR. If a section of the Phase Bus or Switchyard Bus performs any of the license renewal functions listed in 10 CFR 54.4(a), it must be subject to an AMR per the criteria of 10 CFR 54.21(a)(1)(I) (i.e., performs an intended function without moving parts).

Discussion: Following discussions, this question was withdrawn/

D-RAI 2.5.2-2 In Section 2.5.2.5 of the LRA, the electrical commodity groups subject to AMR are described.

Confirm that, in addition to power circuits in the electrical systems, the associated control circuits are also considered in the scoping and screening review, and are included in the electrical commodity groups subject to AMR.

Discussion: The applicant indicated that the question is clear. This D-RAI will be renumbered and sent as a formal RAI.

D-RAI 2.5.2.3-1 In Section 2.5.2.3, the first bullet states: "phase bus exists only in the Main Generator and Auxiliaries System. That system has no electrical intended functions and is in scope for 10 CFR 54.4(a)(2) systems interaction only. Because the phase bus contains no fluid, it has no license renewal intended functions."

Regarding the above first bullet, provide additional information for the following:

a. Provide cross-reference to the phase bus that exists in the SBO path.
b. Confirm whether the Phase Bus (in the Main Generator and Auxiliaries System) provides interactions for 10 CFR 54.4(a)(2) systems? If yes, list the 10 CFR 54.4(a)(2) systems. If 10 CFR 54.4(a)(2) is applicable to this Phase Bus, explain why this Phase Bus is not included as an Electrical Commodity Group subject to AMR.

c.

Explain the purpose of the statement: "Because the phase bus contains no fluid, it has no license renewal intended functions".

Discussion: The applicant indicated that the question is clear. This D-RAI will be sent as a formal RAI.

D-RAI 2.5.2.3-2 In Section 2.5.2.3, the second bullet states: "Switchyard Bus was eliminated because none perform a license renewal intended function. Rather, transmission conductors, high voltage insulators and insulated cables and connectors which perform the functions of providing offsite power to cope with and recover from regulated events."

Regarding the above bullet, list (providing reference to license renewal Drawing No. LR-BR-3000) the circuits that may contain transmission conductors, high voltage insulators, and insulated cables and connectors which perform the functions of providing offsite power to cope with and recover from regulated events. List the regulated events.

Discussion: The applicant indicated that the question is clear. This D-RAI will be sent as a formal RAI.

D-RAI 2.5.2.5-1 In Section 2.5.2.5.3, it is stated that the high voltage insulators are provided on the circuits used to supply power from the switchyard to plant buses during recovery from a station blackout or fire protection event.

Describe the circuit path (which may contain the high voltage insulators) which is relied upon to supply power from the switchyard to plant buses in case of the fire protection event.

Discussion: The applicant indicated that the question is clear. This D-RAI will be sent as a formal RAI.

D-RAI 2.5.2.5-2 In Section 2.5.2.5.4, it is stated that the transmission conductors provide a portion of the circuits used to supply power from the switchyard to plant buses during recovery from a station blackout or fire protection event.

Describe the circuit path (which may contain transmission conductors) which is relied upon to supply power from the switchyard to plant buses in case of the fire protection event.

Discussion: The applicant indicated that the question is clear. This D-RAI will be sent as a formal RAI.