L-HU-06-006, Nuclear Management Company 30-Day Response to Generic Letter 2006-01, Steam Generator Tube Integrity and Associated Technical Specifications.

From kanterella
(Redirected from ML060480537)
Jump to navigation Jump to search

Nuclear Management Company 30-Day Response to Generic Letter 2006-01, Steam Generator Tube Integrity and Associated Technical Specifications.
ML060480537
Person / Time
Site: Palisades, Point Beach, Prairie Island  Entergy icon.png
Issue date: 02/17/2006
From: Weinkam E
Nuclear Management Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
GL-06-001, L-HU-06-006
Download: ML060480537 (2)


Text

Committed to Nuclear Excelience Nuclear Management Company, LLC February 17,2006 L-HU-06-006 10 CFR 50.54(f)

GL 2006-01 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk 11555 Rockville Pike Rockville, Maryland 20852 Palisades Nuclear Plant Point Beach Nuclear Plant Units 1 and 2 Docket 50-255 Dockets 50-266 and 50-301 License No. DPR-20 License Nos. DPR-24 and DPR-27 Prairie Island Nuclear Generating Plant Units 1 and 2 Dockets 50-282 and 50-306 License Nos. DPR-42 and DPR-60 Nuclear Manasement Company 30-Day Response to Generic Letter 2006-01, "Steam Generator Tube Integrity and Associated Technical Specifications."

Reference:

1) Letter L-HU-06-001 from Nuclear Management Company, LLC to Document Control Desk, "Application for Technical Specification Improvement Regarding Steam Generator Tube Integrity", dated February 16, 2006.

By letter dated January 20,2006, the Nuclear Regulatory Commission (NRC) issued Generic Letter (GL) 2006-01. The NRC required that specific information be provided within 30 days of the date of this Generic Letter. The NRC is requesting in Option1 confirmation that licensees have submitted a request to modify the Steam Generator (SG) portion of the Technical Specifications (TS) that is consistent with Technical Specification Task Force (TSTF) 449, Revision 4, or provide a regulatory commitment detailing plans and schedule for submitting such request.

Nuclear Management Company, LLC (NMC) submitted a License Amendment Request (LAR) for the above listed plants on February 16, 2006 (Reference 1). The LAR follows the guidance described in TSTF-449 and, in those cases where deviations are required, explanations have been provided.

700 First Street Hudson, Wisconsin 54016 Telephone: 715.377.3300

Document Control Desk Page 2 Summaw of Commitments This letter contains no new commitments and no revisions to existing commitments.

I declare under penalty of perjury that the foregoing is true and correct.

Executed on d f i W S /7,~@6, k%!hz#censing and Regulatory Services Nuclear Management Company, LLC cc: Administrator, Region Ill, USNRC Project Manager, Palisades Nuclear Plant, Point Beach Nuclear Plant, Prairie Island Nuclear Generating Plant, USNRC Resident Inspector, Palisades Nuclear Plant, Point Beach Nuclear Plant, Prairie Island Nuclear Generating Plant, USNRC

Text

Committed to Nuclear Excelience Nuclear Management Company, LLC February 17,2006 L-HU-06-006 10 CFR 50.54(f)

GL 2006-01 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk 11555 Rockville Pike Rockville, Maryland 20852 Palisades Nuclear Plant Point Beach Nuclear Plant Units 1 and 2 Docket 50-255 Dockets 50-266 and 50-301 License No. DPR-20 License Nos. DPR-24 and DPR-27 Prairie Island Nuclear Generating Plant Units 1 and 2 Dockets 50-282 and 50-306 License Nos. DPR-42 and DPR-60 Nuclear Manasement Company 30-Day Response to Generic Letter 2006-01, "Steam Generator Tube Integrity and Associated Technical Specifications."

Reference:

1) Letter L-HU-06-001 from Nuclear Management Company, LLC to Document Control Desk, "Application for Technical Specification Improvement Regarding Steam Generator Tube Integrity", dated February 16, 2006.

By letter dated January 20,2006, the Nuclear Regulatory Commission (NRC) issued Generic Letter (GL) 2006-01. The NRC required that specific information be provided within 30 days of the date of this Generic Letter. The NRC is requesting in Option1 confirmation that licensees have submitted a request to modify the Steam Generator (SG) portion of the Technical Specifications (TS) that is consistent with Technical Specification Task Force (TSTF) 449, Revision 4, or provide a regulatory commitment detailing plans and schedule for submitting such request.

Nuclear Management Company, LLC (NMC) submitted a License Amendment Request (LAR) for the above listed plants on February 16, 2006 (Reference 1). The LAR follows the guidance described in TSTF-449 and, in those cases where deviations are required, explanations have been provided.

700 First Street Hudson, Wisconsin 54016 Telephone: 715.377.3300

Document Control Desk Page 2 Summaw of Commitments This letter contains no new commitments and no revisions to existing commitments.

I declare under penalty of perjury that the foregoing is true and correct.

Executed on d f i W S /7,~@6, k%!hz#censing and Regulatory Services Nuclear Management Company, LLC cc: Administrator, Region Ill, USNRC Project Manager, Palisades Nuclear Plant, Point Beach Nuclear Plant, Prairie Island Nuclear Generating Plant, USNRC Resident Inspector, Palisades Nuclear Plant, Point Beach Nuclear Plant, Prairie Island Nuclear Generating Plant, USNRC