ES-401 Written Examination Question Worksheet Form-401-5 Examination Outline Cross-reference:

Level RO SRO Tier #

1 Group #

1 K/A #

007.EK1.04 Importance Rating 3.6 Proposed Question:

RO# 1, SEE ATTACHED Proposed Answer:

B Explanation (Optional):

SEE ATTACHED Technical Reference(s):

TRHB 32.4, P. 27 (Attach if not previously provided)

Proposed references to be provided to applicants during examination:

N/A Learning Objective:

032.03.LP0337.006 (As available)

Question Source:

Bank #

Modified Bank (Note changes or attach parent)

New X

Question History:

Last NRC Exam (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question)

Question Cognitive Level:

Memory or Fundamental Knowledge Comprehension or Analysis X

10 CFR Part 55 Content:

55.41 X

55.43 Comments: Knowledge of the operational implications of the following concepts as they apply to the reactor trip: Decrease in reactor power following reactor trip (prompt drop and subsequent decay)

NUREG-1021, Revision 9

ES-401 Written Examination Question Worksheet Form-401-5 Examination Outline Cross-reference:

Level RO SRO Tier #

1 Group #

1 K/A #

008.AK1.02 Importance Rating 3.1 Proposed Question:

RO# 2, SEE ATTACHED Proposed Answer:

D Explanation (Optional):

SEE ATTACHED Technical Reference(s):

EOP-1.2, SB LOCA Cooldown and Depressurization and

Background

(Attach if not previously provided)

Proposed references to be provided to applicants during examination:

N/A Learning Objective:

031.02.LP0435.008 (As available)

Question Source:

Bank #

INPO 26415 Modified Bank (Note changes or attach parent)

New Question History:

Last NRC Exam Byron, 12/10/2003 (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question)

Question Cognitive Level:

Memory or Fundamental Knowledge Comprehension or Analysis X

10 CFR Part 55 Content:

55.41 X

55.43 Comments: Knowledge of the operational implications of the following concepts as they apply a Pressurizer Vapor Space Accident: Change in leak rate with change in pressure.

NUREG-1021, Revision 9

ES-401 Written Examination Question Worksheet Form-401-5 Examination Outline Cross-reference:

Level RO SRO Tier #

1 Group #

1 K/A #

009.2.1.32 Importance Rating 3.4 Proposed Question:

RO# 3, SEE ATTACHED Proposed Answer:

D Explanation (Optional):

SEE ATTACHED Technical Reference(s):

AOP-1A, Reactor Coolant Leak, Step 1 (Attach if not previously provided)

Proposed references to be provided to applicants during examination:

N/A Learning Objective:

055.03.LP2438.005 (As available)

Question Source:

Bank #

Modified Bank (Note changes or attach parent)

New X

Question History:

Last NRC Exam (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question)

Question Cognitive Level:

Memory or Fundamental Knowledge Comprehension or Analysis X

10 CFR Part 55 Content:

55.41 X

55.43 X

Comments: Ability to explain and apply all system limits and precautions. (Small Break LOCA)

NUREG-1021, Revision 9

ES-401 Written Examination Question Worksheet Form-401-5 Examination Outline Cross-reference:

Level RO SRO Tier #

1 Group #

1 K/A #

011.EA2.05 Importance Rating 3.3 Proposed Question:

RO# 4, SEE ATTACHED Proposed Answer:

A Explanation (Optional):

SEE ATTACHED Technical Reference(s):

ECA-1.1, Loss of Containment Sump Recirc. & Background (Attach if not previously provided)

Proposed references to be provided to applicants during examination:

N/A Learning Objective:

031.02.LP0435.015 (As available)

Question Source:

Bank #

Modified Bank (Note changes or attach parent)

New X

Question History:

Last NRC Exam (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question)

Question Cognitive Level:

Memory or Fundamental Knowledge X

Comprehension or Analysis 10 CFR Part 55 Content:

55.41 55.43 X

Comments: Ability to determine or interpret the following as they apply to a Large Break LOCA:

Significance of charging pump operation.

NUREG-1021, Revision 9

ES-401 Written Examination Question Worksheet Form-401-5 Examination Outline Cross-reference:

Level RO SRO Tier #

1 Group #

1 K/A #

015.AK3.03 Importance Rating 3.7 Proposed Question:

RO# 5, SEE ATTACHED Proposed Answer:

C Explanation (Optional):

SEE ATTACHED Technical Reference(s):

AOP-1B, Reactor Coolant Pump Malfunction (Attach if not previously provided)

Proposed references to be provided to applicants during examination:

N/A Learning Objective:

055.03.LP2438.003 (As available)

Question Source:

Bank #

INPO 24348 Modified Bank (Note changes or attach parent)

New Question History:

Last NRC Exam Summer, 9/17/2002 (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question)

Question Cognitive Level:

Memory or Fundamental Knowledge X

Comprehension or Analysis 10 CFR Part 55 Content:

55.41 X

55.43 Comments: Knowledge of the reasons for the following responses as they apply to the Reactor Coolant Pump Malfunctions (Loss of RC Flow) : Sequence of events for manually tripping reactor and RCP as a result of an RCP malfunction.

NUREG-1021, Revision 9

ES-401 Written Examination Question Worksheet Form-401-5 Examination Outline Cross-reference:

Level RO SRO Tier #

1 Group #

1 K/A #

022.AK1.01 Importance Rating 2.8 Proposed Question:

RO# 6, SEE ATTACHED Proposed Answer:

A Explanation (Optional):

SEE ATTACHED Technical Reference(s):

ECA-0.0, Loss of All AC Power Background (Attach if not previously provided)

Proposed references to be provided to applicants during examination:

N/A Learning Objective:

031.02.LP0462.004 (As available)

Question Source:

Bank #

INPO 22948 Modified Bank (Note changes or attach parent)

New Question History:

Last NRC Exam Prairie Island, 8/16/2002 (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question)

Question Cognitive Level:

Memory or Fundamental Knowledge X

Comprehension or Analysis 10 CFR Part 55 Content:

55.41 X

55.43 Comments: Knowledge of the operational implications of the following concepts as they apply to Loss of Reactor Coolant Pump Makeup: Consequences of thermal shock to RCP seals.

NUREG-1021, Revision 9

ES-401 Written Examination Question Worksheet Form-401-5 Examination Outline Cross-reference:

Level RO SRO Tier #

1 Group #

1 K/A #

025.AA2.05 Importance Rating 3.1 Proposed Question:

RO# 7, SEE ATTACHED Proposed Answer:

B Explanation (Optional):

SEE ATTACHED Technical Reference(s):

OP-7A, Placing RHR in Service/SEP-1, Degraded RHR Capacity/TRM 2.2, PTLR (Attach if not previously provided)

Proposed references to be provided to applicants during examination:

N/A Learning Objective:

051.03.LP0069.009 (As available)

Question Source:

Bank #

Modified Bank (Note changes or attach parent)

New X

Question History:

Last NRC Exam (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question)

Question Cognitive Level:

Memory or Fundamental Knowledge X

Comprehension or Analysis 10 CFR Part 55 Content:

55.41 55.43 X

Comments: Ability to determine and interpret the following as they apply to the Loss of Residual Heat Removal System: Limitations on LPI flow and temperature rates of change.

NUREG-1021, Revision 9

ES-401 Written Examination Question Worksheet Form-401-5 Examination Outline Cross-reference:

Level RO SRO Tier #

1 Group #

1 K/A #

027.2.1.33 Importance Rating 3.4 Proposed Question:

RO# 8, SEE ATTACHED Proposed Answer:

A Explanation (Optional):

SEE ATTACHED Technical Reference(s):

TS 3.4.1, Min PZR Press/TRM 2.1, Min PZR Press/STPT 1.4, PZR Press Trips/SL 2.0, Hi Press SL (Attach if not previously provided)

Proposed references to be provided to applicants during examination:

N/A Learning Objective:

051.01.LP0078.08/09 (As available)

Question Source:

Bank #

Modified Bank (Note changes or attach parent)

New X

Question History:

Last NRC Exam (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question)

Question Cognitive Level:

Memory or Fundamental Knowledge Comprehension or Analysis X

10 CFR Part 55 Content:

55.41 55.43 X

Comments: Ability to recognize indications for system operating parameters which are entry-level conditions for technical specifications. (Pressurizer Pressure Control Malfunction)

NUREG-1021, Revision 9

ES-401 Written Examination Question Worksheet Form-401-5 Examination Outline Cross-reference:

Level RO SRO Tier #

1 Group #

1 K/A #

029.EA1.02 Importance Rating 3.6 Proposed Question:

RO# 9, SEE ATTACHED Proposed Answer:

B Explanation (Optional):

SEE ATTACHED Technical Reference(s):

CSP-S.1, Response to Nuclear Power Generation/ATWS, Steps 4 & 5 (Attach if not previously provided)

Proposed references to be provided to applicants during examination:

N/A Learning Objective:

043.03.LP1996.012 (As available)

Question Source:

Bank #

Modified Bank (Note changes or attach parent)

New X

Question History:

Last NRC Exam (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question)

Question Cognitive Level:

Memory or Fundamental Knowledge X

Comprehension or Analysis 10 CFR Part 55 Content:

55.41 X

55.43 Comments: Ability to operate and monitor the following as they apply to a ATWS: Charging pump suction valves from RWST operating switch.

NUREG-1021, Revision 9

ES-401 Written Examination Question Worksheet Form-401-5 Examination Outline Cross-reference:

Level RO SRO Tier #

1 Group #

1 K/A #

038.EK3.04 Importance Rating 3.9 Proposed Question:

RO# 10, SEE ATTACHED Proposed Answer:

C Explanation (Optional):

SEE ATTACHED Technical Reference(s):

RMS ARB for 2RE-222 and 2RE-219 (Attach if not previously provided)

Proposed references to be provided to applicants during examination:

N/A Learning Objective:

052.02.LP0037.004 (As available)

Question Source:

Bank #

Modified Bank (Note changes or attach parent)

New X

Question History:

Last NRC Exam (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question)

Question Cognitive Level:

Memory or Fundamental Knowledge X

Comprehension or Analysis 10 CFR Part 55 Content:

55.41 X

55.43 Comments: Knowledge of the reasons for the following responses as they apply to the SGTR:

Automatic actions provided by each PRM.

NUREG-1021, Revision 9

ES-401 Written Examination Question Worksheet Form-401-5 Examination Outline Cross-reference:

Level RO SRO Tier #

1 Group #

1 K/A #

WE12.EK3.04 Importance Rating 3.5 Proposed Question:

RO# 11, SEE ATTACHED Proposed Answer:

D Explanation (Optional):

SEE ATTACHED Technical Reference(s):

ECA-2.1, Uncontrolled Depressurization of Both SGs, Step 5 (Attach if not previously provided)

Proposed references to be provided to applicants during examination:

N/A Learning Objective:

031.02.LP0465.001 (As available)

Question Source:

Bank #

Modified Bank (Note changes or attach parent)

New X

Question History:

Last NRC Exam (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question)

Question Cognitive Level:

Memory or Fundamental Knowledge Comprehension or Analysis X

10 CFR Part 55 Content:

55.41 X

55.43 Comments: Knowledge of the reasons for the following responses as they apply to the (Uncontrolled Depressurization of all Steam Generators): RO or SRO function within the control room team as appropriate to the assigned position, in such a way that procedures are adhered to and the limitations in the facility's license and amendments are not violated.

NUREG-1021, Revision 9

ES-401 Written Examination Question Worksheet Form-401-5 Examination Outline Cross-reference:

Level RO SRO Tier #

1 Group #

1 K/A #

054.AK3.02 Importance Rating 3.4 Proposed Question:

RO# 12, SEE ATTACHED Proposed Answer:

C Explanation (Optional):

SEE ATTACHED Technical Reference(s):

AOP-2B, Feedwater System Malfunction (Attach if not previously provided)

Proposed references to be provided to applicants during examination:

N/A Learning Objective:

055.03.LP2439.001 (As available)

Question Source:

Bank #

Modified Bank (Note changes or attach parent)

New X

Question History:

Last NRC Exam (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question)

Question Cognitive Level:

Memory or Fundamental Knowledge Comprehension or Analysis X

10 CFR Part 55 Content:

55.41 X

55.43 Comments: Knowledge of the reasons for the following responses as they apply to the Loss of Main Feedwater (MFW): Matching of feedwater and steam flows.

NUREG-1021, Revision 9

ES-401 Written Examination Question Worksheet Form-401-5 Examination Outline Cross-reference:

Level RO SRO Tier #

1 Group #

1 K/A #

055.EA2.01 Importance Rating 3.4 Proposed Question:

RO# 13, SEE ATTACHED Proposed Answer:

A Explanation (Optional):

SEE ATTACHED Technical Reference(s):

AOP-5B, Loss of Instrument Air, Attachment R (Attach if not previously provided)

Proposed references to be provided to applicants during examination:

N/A Learning Objective:

052.05.LP0169.006 (As available)

Question Source:

Bank #

Modified Bank (Note changes or attach parent)

New X

Question History:

Last NRC Exam (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question)

Question Cognitive Level:

Memory or Fundamental Knowledge X

Comprehension or Analysis 10 CFR Part 55 Content:

55.41 55.43 X

Comments: Ability to determine or interpret the following as they apply to a Station Blackout:

Existing valve positioning on a loss of instrument air system.

NUREG-1021, Revision 9

ES-401 Written Examination Question Worksheet Form-401-5 Examination Outline Cross-reference:

Level RO SRO Tier #

1 Group #

1 K/A #

056.2.1.07 Importance Rating 3.7 Proposed Question:

RO# 14, SEE ATTACHED Proposed Answer:

A Explanation (Optional):

SEE ATTACHED Technical Reference(s):

EOP-0.1, Reactor Trip Response, Step 25 RNO (Attach if not previously provided)

Proposed references to be provided to applicants during examination:

N/A Learning Objective:

040.02.LP0378.005 (As available)

Question Source:

Bank #

INPO 20876 Modified Bank (Note changes or attach parent)

New Question History:

Last NRC Exam Byron, 6/29/2000 (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question)

Question Cognitive Level:

Memory or Fundamental Knowledge X

Comprehension or Analysis 10 CFR Part 55 Content:

55.41 55.43 X

Comments: Ability to evaluate plant performance and make operational judgments based on operating characteristics, reactor behavior, and instrument interpretation. (Loss of Off-Site Power)

NUREG-1021, Revision 9

ES-401 Written Examination Question Worksheet Form-401-5 Examination Outline Cross-reference:

Level RO SRO Tier #

1 Group #

1 K/A #

058.AA1.02 Importance Rating 3.1 Proposed Question:

RO# 15, SEE ATTACHED Proposed Answer:

B Explanation (Optional):

SEE ATTACHED Technical Reference(s):

SCI Tech Manual Drawings (Attach if not previously provided)

Proposed references to be provided to applicants during examination:

N/A Learning Objective:

054.02.LP0123.001 (As available)

Question Source:

Bank #

Modified Bank (Note changes or attach parent)

New X

Question History:

Last NRC Exam (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question)

Question Cognitive Level:

Memory or Fundamental Knowledge Comprehension or Analysis X

10 CFR Part 55 Content:

55.41 X

55.43 Comments: Ability to operate and /or monitor the following as they apply to the Loss of DC Power:

Static inverter dc input breaker, frequency meter, ac output breaker, and ground fault detector.

NUREG-1021, Revision 9

ES-401 Written Examination Question Worksheet Form-401-5 Examination Outline Cross-reference:

Level RO SRO Tier #

1 Group #

1 K/A #

065.AA1.05 Importance Rating 3.3 Proposed Question:

RO# 16, SEE ATTACHED Proposed Answer:

B Explanation (Optional):

SEE ATTACHED Technical Reference(s):

AOP-5B, Loss of Instrument Air, Step 5 (Attach if not previously provided)

Proposed references to be provided to applicants during examination:

N/A Learning Objective:

055.03.LP2439.005 (As available)

Question Source:

Bank #

INPO 21279 Modified Bank (Note changes or attach parent)

New Question History:

Last NRC Exam Prairie Island, 5/15/2000 (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question)

Question Cognitive Level:

Memory or Fundamental Knowledge X

Comprehension or Analysis 10 CFR Part 55 Content:

55.41 X

55.43 Comments: Ability to operate and / or monitor the following as they apply to the Loss of Instrument air: RPS.

NUREG-1021, Revision 9

ES-401 Written Examination Question Worksheet Form-401-5 Examination Outline Cross-reference:

Level RO SRO Tier #

1 Group #

1 K/A #

WE04.EK2.01 Importance Rating 3.5 Proposed Question:

RO# 17, SEE ATTACHED Proposed Answer:

B Explanation (Optional):

SEE ATTACHED Technical Reference(s):

ECA-1.2, LOCA Outside Containment Background (Attach if not previously provided)

Proposed references to be provided to applicants during examination:

N/A Learning Objective:

031.02.LP0465.004 (As available)

Question Source:

Bank #

INPO 21244 Modified Bank (Note changes or attach parent)

New Question History:

Last NRC Exam Prairie Island, 5/15/2000 (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question)

Question Cognitive Level:

Memory or Fundamental Knowledge X

Comprehension or Analysis 10 CFR Part 55 Content:

55.41 X

55.43 Comments: Knowledge of the interrelations between the (LOCA Outside Containment) and the following: Components, and functions and control and safety systems, including instrumentation, signals, interlocks, failure modes, and automatic and manual features.

NUREG-1021, Revision 9

ES-401 Written Examination Question Worksheet Form-401-5 Examination Outline Cross-reference:

Level RO SRO Tier #

1 Group #

1 K/A #

WE05.2.4.31 Importance Rating 3.3 Proposed Question:

RO# 18, SEE ATTACHED Proposed Answer:

C Explanation (Optional):

SEE ATTACHED Technical Reference(s):

OI-62B, TDAFW System/ARB C01 A 2-8, AFW System Disabled Alarm (Attach if not previously provided)

Proposed references to be provided to applicants during examination:

N/A Learning Objective:

052.05.LP0169.009 (As available)

Question Source:

Bank #

INPO 26211 Modified Bank (Note changes or attach parent)

New Question History:

Last NRC Exam Point Beach, 9/29/2003 (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question)

Question Cognitive Level:

Memory or Fundamental Knowledge Comprehension or Analysis X

10 CFR Part 55 Content:

55.41 X

55.43 Comments: Knowledge of annunciators alarms and indications, and use of the response instructions.

(Loss of Secondary Heat Sink)

NUREG-1021, Revision 9

ES-401 Written Examination Question Worksheet Form-401-5 Examination Outline Cross-reference:

Level RO SRO Tier #

1 Group #

2 K/A #

005.AK3.02 Importance Rating 3.6 Proposed Question:

RO# 19, SEE ATTACHED Proposed Answer:

C Explanation (Optional):

SEE ATTACHED Technical Reference(s):

AOP-6B, Stuck or Misaligned Rod and Background/ARB for RIL Bank D LO, TS 3.1.1 Bases, STPT 6.1 (Attach if not previously provided)

Proposed references to be provided to applicants during examination:

N/A Learning Objective:

057.02.LP3338.001 (As available)

Question Source:

Bank #

Modified Bank (Note changes or attach parent)

New X

Question History:

Last NRC Exam (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question)

Question Cognitive Level:

Memory or Fundamental Knowledge Comprehension or Analysis X

10 CFR Part 55 Content:

55.41 X

55.43 Comments: Knowledge of the reasons for the following responses as they apply to the Inoperable /

Stuck Control Rod: Rod insertion limits.

NUREG-1021, Revision 9

ES-401 Written Examination Question Worksheet Form-401-5 Examination Outline Cross-reference:

Level RO SRO Tier #

1 Group #

2 K/A #

028.AK3.05 Importance Rating 3.7 Proposed Question:

RO# 20, SEE ATTACHED Proposed Answer:

D Explanation (Optional):

SEE ATTACHED Technical Reference(s):

AOP-24, Response to Instrument Malfunction/AOP-1D, CVCS Malfunction (Attach if not previously provided)

Proposed references to be provided to applicants during examination:

N/A Learning Objective:

055.03.LP2447.001 (As available)

Question Source:

Bank #

Modified Bank (Note changes or attach parent)

New X

Question History:

Last NRC Exam (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question)

Question Cognitive Level:

Memory or Fundamental Knowledge Comprehension or Analysis X

10 CFR Part 55 Content:

55.41 X

55.43 Comments: Knowledge of the reasons for the following responses as they apply to the Pressurizer Level Control Malfunctions: Actions contained in EOP for PZR level malfunctions.

NUREG-1021, Revision 9

ES-401 Written Examination Question Worksheet Form-401-5 Examination Outline Cross-reference:

Level RO SRO Tier #

1 Group #

2 K/A #

037.AA1.11 Importance Rating 3.4 Proposed Question:

RO# 21, SEE ATTACHED Proposed Answer:

B Explanation (Optional):

SEE ATTACHED Technical Reference(s):

AOP-3, Steam Generator Tube Leak Foldout Page (Attach if not previously provided)

Proposed references to be provided to applicants during examination:

N/A Learning Objective:

055.03.LP2438.004 (As available)

Question Source:

Bank #

INPO 22951 Modified Bank (Note changes or attach parent)

New Question History:

Last NRC Exam Prairie Island, 8/16/2002 (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question)

Question Cognitive Level:

Memory or Fundamental Knowledge X

Comprehension or Analysis 10 CFR Part 55 Content:

55.41 X

55.43 Comments: Ability to operate and / or monitor the following as they apply to the Steam Generator Tube Leak: PZR level indicator.

NUREG-1021, Revision 9

ES-401 Written Examination Question Worksheet Form-401-5 Examination Outline Cross-reference:

Level RO SRO Tier #

1 Group #

2 K/A #

051.2.4.50 Importance Rating 3.3 Proposed Question:

RO# 22, SEE ATTACHED Proposed Answer:

C Explanation (Optional):

SEE ATTACHED Technical Reference(s):

AOP-5A, Loss of Condenser Vacuum/Condenser Vacuum ARBs/STPT 14.2 and 15.1 (Attach if not previously provided)

Proposed references to be provided to applicants during examination:

AOP-5A, Figure 1 Learning Objective:

055.03.LP2439.005 (As available)

Question Source:

Bank #

Modified Bank (Note changes or attach parent)

New X

Question History:

Last NRC Exam (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question)

Question Cognitive Level:

Memory or Fundamental Knowledge Comprehension or Analysis X

10 CFR Part 55 Content:

55.41 55.43 Comments: Ability to verify system alarm setpoints and operate controls identified in the alarm response manual. (Loss of Condenser Vacuum)

NUREG-1021, Revision 9

ES-401 Written Examination Question Worksheet Form-401-5 Examination Outline Cross-reference:

Level RO SRO Tier #

1 Group #

2 K/A #

060.2.2.22 Importance Rating 3.4 Proposed Question:

RO# 23, SEE ATTACHED Proposed Answer:

A Explanation (Optional):

SEE ATTACHED Technical Reference(s):

TS 5.5.4, Radioactive Effluent Controls Program (Attach if not previously provided)

Proposed references to be provided to applicants during examination:

N/A Learning Objective:

057.02.LP1267.004 (As available)

Question Source:

Bank #

Modified Bank (Note changes or attach parent)

New X

Question History:

Last NRC Exam (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question)

Question Cognitive Level:

Memory or Fundamental Knowledge X

Comprehension or Analysis 10 CFR Part 55 Content:

55.41 55.43 X

Comments: Knowledge of limiting conditions for operations and safety limits. (Accidental Gaseous-Waste Release)

NUREG-1021, Revision 9

ES-401 Written Examination Question Worksheet Form-401-5 Examination Outline Cross-reference:

Level RO SRO Tier #

1 Group #

2 K/A #

061.AK2.01 Importance Rating 2.5 Proposed Question:

RO# 24, SEE ATTACHED Proposed Answer:

D Explanation (Optional):

SEE ATTACHED Technical Reference(s):

RMS ARB for locations of listed Radiation Monitors (Attach if not previously provided)

Proposed references to be provided to applicants during examination:

N/A Learning Objective:

051.07.LP0275.001 (As available)

Question Source:

Bank #

Modified Bank (Note changes or attach parent)

New X

Question History:

Last NRC Exam (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question)

Question Cognitive Level:

Memory or Fundamental Knowledge X

Comprehension or Analysis 10 CFR Part 55 Content:

55.41 X

55.43 Comments: Knowledge of the interrelations between the Area Radiation Monitoring (ARM) System Alarms and the following: Detectors at each ARM system location.

NUREG-1021, Revision 9

ES-401 Written Examination Question Worksheet Form-401-5 Examination Outline Cross-reference:

Level RO SRO Tier #

1 Group #

2 K/A #

068.AK2.02 Importance Rating 3.7 Proposed Question:

RO# 25, SEE ATTACHED Proposed Answer:

C Explanation (Optional):

SEE ATTACHED Technical Reference(s):

AOP-10A, Safe Shutdown - Local Control (Attach if not previously provided)

Proposed references to be provided to applicants during examination:

N/A Learning Objective:

055.03.LP1275.003 (As available)

Question Source:

Bank #

INPO 20576 Modified Bank (Note changes or attach parent)

New Question History:

Last NRC Exam Point Beach, 2/2/2002 (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question)

Question Cognitive Level:

Memory or Fundamental Knowledge X

Comprehension or Analysis 10 CFR Part 55 Content:

55.41 X

55.43 Comments: Knowledge of the interrelations between the Control Room Evacuation and the following: Reactor trip system.

NUREG-1021, Revision 9

ES-401 Written Examination Question Worksheet Form-401-5 Examination Outline Cross-reference:

Level RO SRO Tier #

1 Group #

2 K/A #

WE16.EA2.02 Importance Rating 3.0 Proposed Question:

RO# 26, SEE ATTACHED Proposed Answer:

C Explanation (Optional):

SEE ATTACHED Technical Reference(s):

EOP-0, Reactor Trip or Safety Injection Foldout Page and

Background

(Attach if not previously provided)

Proposed references to be provided to applicants during examination:

N/A Learning Objective:

031.02.LP0405.010 (As available)

Question Source:

Bank #

Modified Bank (Note changes or attach parent)

New X

Question History:

Last NRC Exam (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question)

Question Cognitive Level:

Memory or Fundamental Knowledge X

Comprehension or Analysis 10 CFR Part 55 Content:

55.41 55.43 X

Comments: Ability to determine and interpret the following as they apply to the (High Containment Radiation): Adherence to appropriate procedures and operation within the limitations in the facility's license and amendments.

NUREG-1021, Revision 9

ES-401 Written Examination Question Worksheet Form-401-5 Examination Outline Cross-reference:

Level RO SRO Tier #

1 Group #

2 K/A #

WE03.EA1.01 Importance Rating 4.0 Proposed Question:

RO# 27, SEE ATTACHED Proposed Answer:

B Explanation (Optional):

SEE ATTACHED Technical Reference(s):

EOP-1.2, SB LOCA Cooldown and Depressurization (Attach if not previously provided)

Proposed references to be provided to applicants during examination:

N/A Learning Objective:

031.02.LP0435.010 (As available)

Question Source:

Bank #

Modified Bank (Note changes or attach parent)

New X

Question History:

Last NRC Exam (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question)

Question Cognitive Level:

Memory or Fundamental Knowledge Comprehension or Analysis X

10 CFR Part 55 Content:

55.41 X

55.43 Comments: Ability to operate and / or monitor the following as they apply to the (LOCA Cooldown and Depressurization): Components, and functions of control and safety systems, including instrumentation, signals, interlocks, failure modes, and automatic and manual features.

NUREG-1021, Revision 9

ES-401 Written Examination Question Worksheet Form-401-5 Examination Outline Cross-reference:

Level RO SRO Tier #

2 Group #

1 K/A #

003.K3.03 Importance Rating 2.8 Proposed Question:

RO# 28, SEE ATTACHED Proposed Answer:

B Explanation (Optional):

SEE ATTACHED Technical Reference(s):

Heat Transfer Fundamentals and LP0378, Natural Circulation (Attach if not previously provided)

Proposed references to be provided to applicants during examination:

N/A Learning Objective:

040.02.LP0378.002 (As available)

Question Source:

Bank #

Modified Bank (Note changes or attach parent)

New X

Question History:

Last NRC Exam (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question)

Question Cognitive Level:

Memory or Fundamental Knowledge Comprehension or Analysis X

10 CFR Part 55 Content:

55.41 X

55.43 Comments: Knowledge of the effect that a loss or malfunction of the RCPS will have on the following: Feedwater and emergency feedwater.

NUREG-1021, Revision 9

ES-401 Written Examination Question Worksheet Form-401-5 Examination Outline Cross-reference:

Level RO SRO Tier #

2 Group #

1 K/A #

003.A3.02 Importance Rating 2.6 Proposed Question:

RO# 29, SEE ATTACHED Proposed Answer:

C Explanation (Optional):

SEE ATTACHED Technical Reference(s):

OP-4B, Reactor Coolant Pump Operation (Attach if not previously provided)

Proposed references to be provided to applicants during examination:

N/A Learning Objective:

055.02.LP0162.001 (As available)

Question Source:

Bank #

Modified Bank (Note changes or attach parent)

New X

Question History:

Last NRC Exam (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question)

Question Cognitive Level:

Memory or Fundamental Knowledge X

Comprehension or Analysis 10 CFR Part 55 Content:

55.41 X

55.43 Comments: Ability to monitor automatic operation of the RCPS, including: Motor Current.

NUREG-1021, Revision 9

ES-401 Written Examination Question Worksheet Form-401-5 Examination Outline Cross-reference:

Level RO SRO Tier #

2 Group #

1 K/A #

004.K5.30 Importance Rating 3.8 Proposed Question:

RO# 30, SEE ATTACHED Proposed Answer:

D Explanation (Optional):

SEE ATTACHED Technical Reference(s):

1-SOP-CC-001, Component Cooling System, Attachment D (Attach if not previously provided)

Proposed references to be provided to applicants during examination:

N/A Learning Objective:

051.03.LP0069.010 (As available)

Question Source:

Bank #

INPO 26245 Modified Bank (Note changes or attach parent)

New Question History:

Last NRC Exam Point Beach, 2/2/2002 (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question)

Question Cognitive Level:

Memory or Fundamental Knowledge Comprehension or Analysis X

10 CFR Part 55 Content:

55.41 X

55.43 Comments: Knowledge of the operational implications of the following concepts as they apply to the CVCS: Relationship between temperature and pressure in CVCS components during solid plant operation.

NUREG-1021, Revision 9

ES-401 Written Examination Question Worksheet Form-401-5 Examination Outline Cross-reference:

Level RO SRO Tier #

2 Group #

1 K/A #

004.K6.24 Importance Rating 2.5 Proposed Question:

RO# 31, SEE ATTACHED Proposed Answer:

C Explanation (Optional):

SEE ATTACHED Technical Reference(s):

AOP-1D, CVCS Malfunction and Background/CVCS Drawing Sheet 2.

(Attach if not previously provided)

Proposed references to be provided to applicants during examination:

N/A Learning Objective:

055.03.LP3718.001 (As available)

Question Source:

Bank #

Modified Bank (Note changes or attach parent)

New X

Question History:

Last NRC Exam (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question)

Question Cognitive Level:

Memory or Fundamental Knowledge Comprehension or Analysis X

10 CFR Part 55 Content:

55.41 X

55.43 Comments: Knowledge of the effect of a loss or malfunction on the following CVCS components:

Controllers and positioners.

NUREG-1021, Revision 9

ES-401 Written Examination Question Worksheet Form-401-5 Examination Outline Cross-reference:

Level RO SRO Tier #

2 Group #

1 K/A #

005.K3.06 Importance Rating 3.1 Proposed Question:

RO# 32, SEE ATTACHED Proposed Answer:

B Explanation (Optional):

SEE ATTACHED Technical Reference(s):

STPT 8.1, Auxiliary Coolant System (Attach if not previously provided)

Proposed references to be provided to applicants during examination:

N/A Learning Objective:

051.03.LP0064.004 (As available)

Question Source:

Bank #

Modified Bank (Note changes or attach parent)

New X

Question History:

Last NRC Exam (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question)

Question Cognitive Level:

Memory or Fundamental Knowledge X

Comprehension or Analysis 10 CFR Part 55 Content:

55.41 X

55.43 Comments: Knowledge of the effect that a loss or malfunction of the RHRS will have on the following: CSS.

NUREG-1021, Revision 9

ES-401 Written Examination Question Worksheet Form-401-5 Examination Outline Cross-reference:

Level RO SRO Tier #

2 Group #

1 K/A #

006.K2.01 Importance Rating 3.6 Proposed Question:

RO# 33, SEE ATTACHED Proposed Answer:

A Explanation (Optional):

SEE ATTACHED Technical Reference(s):

Logic Drawings SH. 6/AV-123, PBNP Electric Plant Drawing/MDB for 1A05 and 1B03 (Attach if not previously provided)

Proposed references to be provided to applicants during examination:

N/A Learning Objective:

051.03.LP0066.006 (As available)

Question Source:

Bank #

Modified Bank X 22985 (Note changes or attach parent)

New Question History:

Last NRC Exam Prairie Island, 8/16/2002 (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question)

Question Cognitive Level:

Memory or Fundamental Knowledge Comprehension or Analysis X

10 CFR Part 55 Content:

55.41 X

55.43 Comments: Knowledge of bus power supplies to the following: ECCS pumps.

NUREG-1021, Revision 9

ES-401 Written Examination Question Worksheet Form-401-5 Examination Outline Cross-reference:

Level RO SRO Tier #

2 Group #

1 K/A #

006.A3.06 Importance Rating 3.9 Proposed Question:

RO# 34, SEE ATTACHED Proposed Answer:

D Explanation (Optional):

SEE ATTACHED Technical Reference(s):

EOP-0, Reactor Trip or Safety Injection, ATT. A, SI Drawing (Attach if not previously provided)

Proposed references to be provided to applicants during examination:

N/A Learning Objective:

051.03.LP0066.006 (As available)

Question Source:

Bank #

Modified Bank (Note changes or attach parent)

New X

Question History:

Last NRC Exam (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question)

Question Cognitive Level:

Memory or Fundamental Knowledge Comprehension or Analysis X

10 CFR Part 55 Content:

55.41 X

55.43 Comments: Ability to monitor automatic operation of the ECCS, including: Valve lineups.

NUREG-1021, Revision 9

ES-401 Written Examination Question Worksheet Form-401-5 Examination Outline Cross-reference:

Level RO SRO Tier #

2 Group #

1 K/A #

007.K3.01 Importance Rating 3.3 Proposed Question:

RO# 35, SEE ATTACHED Proposed Answer:

B Explanation (Optional):

SEE ATTACHED Technical Reference(s):

ARB for 1RE-211, ARP for Containment Humidity, LP0078 for PRT function and rupture disc.

(Attach if not previously provided)

Proposed references to be provided to applicants during examination:

N/A Learning Objective:

031.02.LP0435.002 (As available)

Question Source:

Bank #

INPO 19361 Modified Bank (Note changes or attach parent)

New Question History:

Last NRC Exam Kewaunee, 12/11/2000 (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question)

Question Cognitive Level:

Memory or Fundamental Knowledge Comprehension or Analysis X

10 CFR Part 55 Content:

55.41 X

55.43 Comments: Knowledge of the effect that a loss or malfunction of the PRTS will have on the following: Containment.

NUREG-1021, Revision 9

ES-401 Written Examination Question Worksheet Form-401-5 Examination Outline Cross-reference:

Level RO SRO Tier #

2 Group #

1 K/A #

007.A1.03 Importance Rating 2.6 Proposed Question:

RO# 36, SEE ATTACHED Proposed Answer:

D Explanation (Optional):

SEE ATTACHED Technical Reference(s):

ARB 1C04 1C 1-1 for PRT parameters/STPT 10.1 for setpoints (Attach if not previously provided)

Proposed references to be provided to applicants during examination:

N/A Learning Objective:

051.01.LP0078.005 (As available)

Question Source:

Bank #

Modified Bank X 19360 (Note changes or attach parent)

New Question History:

Last NRC Exam Kewaunee, 12/11/2000 (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question)

Question Cognitive Level:

Memory or Fundamental Knowledge X

Comprehension or Analysis 10 CFR Part 55 Content:

55.41 X

55.43 Comments: Ability to predict and/or monitor changes in parameters (to prevent exceeding design limits) associated with operating the PRTS controls including: Monitoring quench tank temperature.

NUREG-1021, Revision 9

ES-401 Written Examination Question Worksheet Form-401-5 Examination Outline Cross-reference:

Level RO SRO Tier #

2 Group #

1 K/A #

008.K1.02 Importance Rating 3.3 Proposed Question:

RO# 37, SEE ATTACHED Proposed Answer:

B Explanation (Optional):

SEE ATTACHED Technical Reference(s):

Drawings for Component Cooling and Radwaste CCW (Attach if not previously provided)

Proposed references to be provided to applicants during examination:

N/A Learning Objective:

051.06.LP0084.004 (As available)

Question Source:

Bank #

Modified Bank (Note changes or attach parent)

New X

Question History:

Last NRC Exam (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question)

Question Cognitive Level:

Memory or Fundamental Knowledge X

Comprehension or Analysis 10 CFR Part 55 Content:

55.41 X

55.43 Comments: Knowledge of the physical connections and/or cause-effect relationships between the CCWS and the following systems: Loads cooled by CCWS.

NUREG-1021, Revision 9

ES-401 Written Examination Question Worksheet Form-401-5 Examination Outline Cross-reference:

Level RO SRO Tier #

2 Group #

1 K/A #

010.A4.01 Importance Rating 3.7 Proposed Question:

RO# 38, SEE ATTACHED Proposed Answer:

D Explanation (Optional):

SEE ATTACHED Technical Reference(s):

STPT 5.3&6.4 for Pressurizer Backup heater and Spray valve setpoints (Attach if not previously provided)

Proposed references to be provided to applicants during examination:

N/A Learning Objective:

051.01.LP0457.003 (As available)

Question Source:

Bank #

Modified Bank X 26375 (Note changes or attach parent)

New Question History:

Last NRC Exam Byron, 12/10/2003 (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question)

Question Cognitive Level:

Memory or Fundamental Knowledge Comprehension or Analysis X

10 CFR Part 55 Content:

55.41 X

55.43 Comments: Ability to manually operate and/or monitor in the control room: PZR spray valve.

NUREG-1021, Revision 9

ES-401 Written Examination Question Worksheet Form-401-5 Examination Outline Cross-reference:

Level RO SRO Tier #

2 Group #

1 K/A #

012.A1.01 Importance Rating 2.9 Proposed Question:

RO# 39, SEE ATTACHED Proposed Answer:

C Explanation (Optional):

SEE ATTACHED Technical Reference(s):

RESP 1.9, Alternative Method for Determining Power Level (Attach if not previously provided)

Proposed references to be provided to applicants during examination:

N/A Learning Objective:

053.01.LP2416.001 (As available)

Question Source:

Bank #

Modified Bank X 20628 (Note changes or attach parent)

New Question History:

Last NRC Exam Point Beach, 2/2/2002 (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question)

Question Cognitive Level:

Memory or Fundamental Knowledge Comprehension or Analysis X

10 CFR Part 55 Content:

55.41 X

55.43 Comments: Ability to predict and/or monitor changes in parameters (to prevent exceeding design limits) associated with operating the RPS controls including: Trip setpoint adjustment.

NUREG-1021, Revision 9

ES-401 Written Examination Question Worksheet Form-401-5 Examination Outline Cross-reference:

Level RO SRO Tier #

2 Group #

1 K/A #

013.K5.01 Importance Rating 2.8 Proposed Question:

RO# 40, SEE ATTACHED Proposed Answer:

D Explanation (Optional):

SEE ATTACHED Technical Reference(s):

Logic Drawing SH. 7 for SG Pressure Input (Attach if not previously provided)

Proposed references to be provided to applicants during examination:

N/A Learning Objective:

053.06.LP0486.001 (As available)

Question Source:

Bank #

Modified Bank X 21425 (Note changes or attach parent)

New Question History:

Last NRC Exam Braidwood, 7/17/2002 (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question)

Question Cognitive Level:

Memory or Fundamental Knowledge X

Comprehension or Analysis 10 CFR Part 55 Content:

55.41 X

55.43 Comments: Knowledge of the operational implications of the following concepts as they apply to the ESFAS: Definitions of safety train and ESF channel.

NUREG-1021, Revision 9

ES-401 Written Examination Question Worksheet Form-401-5 Examination Outline Cross-reference:

Level RO SRO Tier #

2 Group #

1 K/A #

022.K4.05 Importance Rating 2.6 Proposed Question:

RO# 41, SEE ATTACHED Proposed Answer:

A Explanation (Optional):

SEE ATTACHED Technical Reference(s):

TS 3.6.6B for Containment Spray and Cooling Systems (Attach if not previously provided)

Proposed references to be provided to applicants during examination:

N/A Learning Objective:

051.03.LP0064.001 (As available)

Question Source:

Bank #

Modified Bank (Note changes or attach parent)

New X

Question History:

Last NRC Exam (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question)

Question Cognitive Level:

Memory or Fundamental Knowledge X

Comprehension or Analysis 10 CFR Part 55 Content:

55.41 X

55.43 Comments: Knowledge of CCS design feature(s) and/or interlock(s) which provide for the following:

Containment cooling after LOCA destroys ventilation ducts.

NUREG-1021, Revision 9

ES-401 Written Examination Question Worksheet Form-401-5 Examination Outline Cross-reference:

Level RO SRO Tier #

2 Group #

1 K/A #

026.A2.05 Importance Rating 3.7 Proposed Question:

RO# 42, SEE ATTACHED Proposed Answer:

B Explanation (Optional):

SEE ATTACHED Technical Reference(s):

TS 3.6.7B Spray Additive System basis/OM 3.7, AOP and EOP Procedure Use/EOP-0, Att. A (Attach if not previously provided)

Proposed references to be provided to applicants during examination:

N/A Learning Objective:

051.03.LP0064.001 (As available)

Question Source:

Bank #

Modified Bank (Note changes or attach parent)

New X

Question History:

Last NRC Exam (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question)

Question Cognitive Level:

Memory or Fundamental Knowledge X

Comprehension or Analysis 10 CFR Part 55 Content:

55.41 X

55.43 X

Comments: Ability to (a) predict the impacts of the following malfunctions or operations on the CSS and (b) based on those predictions, use procedures to correct, control, or mitigate the consequences of those malfunctions or operations: Failure of chemical addition tanks to inject.

NUREG-1021, Revision 9

ES-401 Written Examination Question Worksheet Form-401-5 Examination Outline Cross-reference:

Level RO SRO Tier #

2 Group #

1 K/A #

039.A3.02 Importance Rating 3.1 Proposed Question:

RO# 43, SEE ATTACHED Proposed Answer:

B Explanation (Optional):

SEE ATTACHED Technical Reference(s):

STPT 2.2, Steam Line Isolation Setpoints (Attach if not previously provided)

Proposed references to be provided to applicants during examination:

N/A Learning Objective:

031.02.LP0441.003 (As available)

Question Source:

Bank #

Modified Bank (Note changes or attach parent)

New X

Question History:

Last NRC Exam (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question)

Question Cognitive Level:

Memory or Fundamental Knowledge Comprehension or Analysis X

10 CFR Part 55 Content:

55.41 X

55.43 Comments: Ability to monitor automatic operation of the MRSS, including: Isolation of the MRSS.

NUREG-1021, Revision 9

ES-401 Written Examination Question Worksheet Form-401-5 Examination Outline Cross-reference:

Level RO SRO Tier #

2 Group #

1 K/A #

059.K1.02 Importance Rating 3.4 Proposed Question:

RO# 44, SEE ATTACHED Proposed Answer:

A Explanation (Optional):

SEE ATTACHED Technical Reference(s):

Logic Drawing Sh. 20, AFW Pump Start Logic (Attach if not previously provided)

Proposed references to be provided to applicants during examination:

N/A Learning Objective:

052.05.LP0169.004 (As available)

Question Source:

Bank #

Modified Bank (Note changes or attach parent)

New X

Question History:

Last NRC Exam (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question)

Question Cognitive Level:

Memory or Fundamental Knowledge Comprehension or Analysis X

10 CFR Part 55 Content:

55.41 X

55.43 Comments: Knowledge of the physical connections and/or cause-effect relationships between the MFW and the following systems: AFW system.

NUREG-1021, Revision 9

ES-401 Written Examination Question Worksheet Form-401-5 Examination Outline Cross-reference:

Level RO SRO Tier #

2 Group #

1 K/A #

059.2.2.01 Importance Rating 3.7 Proposed Question:

RO# 45, SEE ATTACHED Proposed Answer:

C SEE ATTACHED Technical Reference(s):

Explanation (Optional):

OP-13A, Secondary Systems Startup/STPT 14.2 & 14.8 (Attach if not previously provided)

Proposed references to be provided to applicants during examination:

N/A 052.05.LP0128.004 (As available)

Learning Objective:

Question Source:

Bank #

Modified Bank (Note changes or attach parent)

New X

Question History:

Last NRC Exam (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question)

Question Cognitive Level:

Memory or Fundamental Knowledge X

Comprehension or Analysis 10 CFR Part 55 Content:

55.41 55.43 Comments: Ability to perform pre-startup procedures for the facility, including operating those controls associated with plant equipment that could affect reactivity. (Main Feedwater System)

NUREG-1021, Revision 9

ES-401 Written Examination Question Worksheet Form-401-5 Level RO Tier #

Grou Examination Outline Cross-reference:

SRO 2

p #

1 K/A #

061.K2.02 Importance Rating 3.7 Proposed Question:

RO# 46, SEE ATTACHED Proposed Answer:

D SEE ATTACHED Technical Reference(s):

Explanation (Optional):

Master Data Book for 2B04 (Attach if not previously provided)

Proposed references to be provided to applicants during examination:

N/A 052.05.LP0169.003 (As available)

Learning Objective:

Question Source:

Bank #

Modified Bank (Note changes or attach parent)

New X

Question History:

Last NRC Exam (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question)

Question Cognitive Level:

Memory or Fundamental Knowledge X

Comprehension or Analysis X

10 CFR Part 55 Content:

55.41 55.43 Comments: Knowledge of bus power supplies to the following: AFW electric drive pumps.

NUREG-1021, Revision 9

ES-401 Written Examination Question Worksheet Form-401-5 Level RO Tier #

Grou Examination Outline Cross-reference:

SRO 2

p #

1 K/A #

061.2.4.04 Importance Rating 4.0 Proposed Question:

RO# 47, SEE ATTACHED Proposed Answer:

C SEE ATTACHED Technical Reference(s):

Explanation (Optional):

EOP-0.2, Natural Circulation Cooldown Foldout Page/AOP-23, Establishing Alternate AFW Supply (Attach if not previously provided)

Proposed references to be provided to applicants during examination:

N/A Learning Objective:

052.05.LP0169.009 (As available)

Question Source:

Bank #

Modified Bank (Note changes or attach parent)

New X

Question History:

Last NRC Exam (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question)

Question Cognitive Level:

Memory or Fundamental Knowledge X

Comprehension or Analysis X

10 CFR Part 55 Content:

55.41 55.43 X

Comments: Ability to recognize abnormal indications for system operating parameters which are entry-level conditions for emergency and abnormal operating procedures. (Auxiliary/Emergency Feedwater System)

NUREG-1021, Revision 9

ES-401 Written Examination Question Worksheet Form-401-5 Level RO Tier #

Grou Examination Outline Cross-reference:

SRO 2

p #

1 K/A #

062.A4.03 Importance Rating 2.8 Proposed Question:

RO# 48, SEE ATTACHED Proposed Answer:

A SEE ATTACHED Technical Reference(s):

Explanation (Optional):

TS-81, EDG G01 Monthly TS Test (Attach if not previously provided)

Proposed references to be provided to applicants during examination:

N/A 182.01.LP2519.001 (As available)

Learning Objective:

Question Source:

Bank #

Modified Bank (Note changes or attach parent)

New X

Question History:

Last NRC Exam (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question)

Question Cognitive Level:

Memory or Fundamental Knowledge Comprehension or Analysis X

X 10 CFR Part 55 Content:

55.41 55.43 Comments: Ability to manually operate and/or monitor in the control room: Synchroscope, including an understanding of running and incoming voltages.

NUREG-1021, Revision 9

ES-401 Written Examination Question Worksheet Form-401-5 Level RO Tier #

Grou Examination Outline Cross-reference:

SRO 2

p #

1 K/A #

063.A2.01 Importance Rating 2.5 Proposed Question:

RO# 49, SEE ATTACHED Proposed Answer:

C SEE ATTACHED Technical Reference(s):

Explanation (Optional):

AOP-0.0, Vital DC System Malfunction (Attach if not previously provided)

Proposed references to be provided to applicants during examination:

N/A 055.03.LP3456.001 (As available)

Learning Objective:

Question Source:

Bank #

Modified Bank (Note changes or attach parent)

New X

Question History:

Last NRC Exam (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question)

Question Cognitive Level:

Memory or Fundamental Knowledge X

Comprehension or Analysis X

10 CFR Part 55 Content:

55.41 55.43 X

Comments: Ability to (a) predict the impacts of the following malfunctions or operations on the DC electrical systems; and (b) based on those predictions, use procedures to correct, control, or mitigate the consequences of those malfunctions or operations: Grounds.

NUREG-1021, Revision 9

ES-401 Written Examination Question Worksheet Form-401-5 Level RO Tier #

Grou Examination Outline Cross-reference:

SRO 2

p #

1 K/A #

064.K1.01 Importance Rating 4.1 Proposed Question:

RO# 50, SEE ATTACHED Proposed Answer:

B SEE ATTACHED Technical Reference(s):

Explanation (Optional):

LOGIC SH.6 and 6A for EDG Starting and Loading (Attach if not previously provided)

Proposed references to be provided to applicants during examination:

N/A Learning Objective:

054.02.LP0133.004 (As available)

Question Source:

Bank #

Modified Bank X 20636 (Note changes or attach parent)

New Question History:

Last NRC Exam Cook, 5/21/2001 (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question)

Question Cognitive Level:

Memory or Fundamental Knowledge Comprehension or Analysis X

X 10 CFR Part 55 Content:

55.41 55.43 Comments: Knowledge of the physical connections and/or cause-effect relationships between the EDG system and the following systems: AC distribution system.

NUREG-1021, Revision 9

ES-401 Written Examination Question Worksheet Form-401-5 Level RO Tier #

Grou Examination Outline Cross-reference:

SRO 2

p #

1 K/A #

073.A4.02 Importance Rating 3.7 Proposed Question:

RO# 51, SEE ATTACHED Proposed Answer:

D SEE ATTACHED Technical Reference(s):

Explanation (Optional):

OI-140, Standard Batch Release/RMS ARB for Defininition of Fail External (Attach if not previously provided)

Proposed references to be provided to applicants during examination:

N/A 051.02.LP0313.005 (As available)

Learning Objective:

Question Source:

Bank #

Modified Bank (Note changes or attach parent)

New X

Question History:

Last NRC Exam (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question)

Question Cognitive Level:

Memory or Fundamental Knowledge Comprehension or Analysis X

10 CFR Part 55 Content:

55.41 X

55.43 Comments: Ability to manually operate the and/or monitor in the control room: Radiation monitoring system control panel.

NUREG-1021, Revision 9

ES-401 Written Examination Question Worksheet Form-401-5 RO Grou Examination Outline Cross-reference:

Level SRO Tier #

2 p #

1 K/A #

076.A4.04 Importance Rating 3.5 Proposed Question:

RO# 52, SEE ATTACHED Proposed Answer:

B Technical Reference(s):

Explanation (Optional):

SEE ATTACHED OI-70, Service Water System Operation/EOP-0, Reactor Trip or Safety Injection, Att. A (Attach if not previously provided)

Proposed references to be provided to applicants during examination:

N/A Learning Objective:

051.06.LP0086.008 (As available)

Question Source:

Bank #

INPO 20648 Modified Bank (Note changes or attach parent)

New Question History:

Last NRC Exam Point Beach, 2/2/2002 (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question)

Question Cognitive Level:

Memory or Fundamental Knowledge X

Comprehension or Analysis 10 CFR Part 55 Content:

55.41 X

55.43 Comments: Ability to manually operate and/or monitor in the control room: Emergency heat loads.

NUREG-1021, Revision 9

ES-401 Written Examination Question Worksheet Form-401-5 RO Grou Examination Outline Cross-reference:

Level SRO Tier #

2 p #

1 K/A #

076.2.1.32 Importance Rating 3.4 Proposed Question:

RO# 53, SEE ATTACHED Proposed Answer:

A Technical Reference(s):

Explanation (Optional):

SEE ATTACHED OI-70, Service Water System Operation (Attach if not previously provided)

Proposed references to be provided to applicants during examination:

N/A Learning Objective:

057.02.LP3343.002 (As available)

Question Source:

Bank #

Modified Bank (Note changes or attach parent)

New X

Question History:

Last NRC Exam (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question)

Question Cognitive Level:

Memory or Fundamental Knowledge X

Comprehension or Analysis 10 CFR Part 55 Content:

55.41 X

55.43 X

Comments: Ability to explain and apply all system limits and precautions. (Service Water System)

NUREG-1021, Revision 9

ES-401 Written Examination Question Worksheet Form-401-5 RO Grou Examination Outline Cross-reference:

Level SRO Tier #

2 p #

1 K/A #

078.K4.01 Importance Rating 2.7 Proposed Question:

RO# 54, SEE ATTACHED Proposed Answer:

C Technical Reference(s):

Explanation (Optional):

SEE ATTACHED STPT 14.7, Instrument and Service Air Setpoints (Attach if not previously provided)

Proposed references to be provided to applicants during examination:

N/A Learning Objective:

052.06.LP0338.004 (As available)

Question Source:

Bank #

Modified Bank (Note changes or attach parent)

New X

Question History:

Last NRC Exam (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question)

Question Cognitive Level:

Memory or Fundamental Knowledge Comprehension or Analysis X

10 CFR Part 55 Content:

55.41 X

55.43 Comments: Knowledge of IAS design feature(s) and/or interlock(s) which provide for the following:

Manual/automatic transfers of control.

NUREG-1021, Revision 9

ES-401 Written Examination Question Worksheet Form-401-5 RO Grou Examination Outline Cross-reference:

Level SRO Tier #

2 p #

1 K/A #

103.K3.02 Importance Rating 3.8 Proposed Question:

RO# 55, SEE ATTACHED Proposed Answer:

C Technical Reference(s):

Explanation (Optional):

SEE ATTACHED TS 3.6.1 Basis/TS 3.6.2 Basis/OM 3.26, Use of Dedicated Operators (Attach if not previously provided)

Proposed references to be provided to applicants during examination:

N/A Learning Objective:

057.02.LP3342.002 (As available)

Question Source:

Bank #

INPO 26493 Modified Bank (Note changes or attach parent)

New Question History:

Last NRC Exam Farley, 5/30/2004 (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question)

Question Cognitive Level:

Memory or Fundamental Knowledge Comprehension or Analysis X

10 CFR Part 55 Content:

55.41 X

55.43 Comments: Knowledge of the effect that a loss or malfunction of the containment system will have on the following: Loss of containment integrity under normal operations.

NUREG-1021, Revision 9

ES-401 Written Examination Question Worksheet Form-401-5 RO Grou Examination Outline Cross-reference:

Level SRO Tier #

2 p #

2 K/A #

001.2.4.50 Importance Rating 3.3 Proposed Question:

RO# 56, SEE ATTACHED Proposed Answer:

A Technical Reference(s):

Explanation (Optional):

SEE ATTACHED AOP-6B, Stuck or Misaligned Rod/ARB 1C04 1A 1-6, Rod Control System Urgent Failure (Attach if not previously provided)

Proposed references to be provided to applicants during examination:

N/A Learning Objective:

055.03.LP2441.006 (As available)

Question Source:

Bank #

Modified Bank (Note changes or attach parent)

New X

Question History:

Last NRC Exam (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question)

Question Cognitive Level:

Memory or Fundamental Knowledge Comprehension or Analysis X

10 CFR Part 55 Content:

55.41 55.43 Comments: Ability to verify system alarm setpoints and operate controls identified in the alarm response manual. (Rod Control System)

NUREG-1021, Revision 9

ES-401 Written Examination Question Worksheet Form-401-5 RO Grou Examination Outline Cross-reference:

Level SRO Tier #

2 p #

2 K/A #

002.K6.03 Importance Rating 3.1 Proposed Question:

RO# 57, SEE ATTACHED Proposed Answer:

A Technical Reference(s):

Explanation (Optional):

SEE ATTACHED EOP-0.2, Natural Circulation Cooldown Background (Attach if not previously provided)

Proposed references to be provided to applicants during examination:

N/A Learning Objective:

031.02.LP0407.002 (As available)

Question Source:

Bank #

INPO 2782 Modified Bank (Note changes or attach parent)

New Question History:

Last NRC Exam Point Beach, 8/2/1999 (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question)

Question Cognitive Level:

Memory or Fundamental Knowledge Comprehension or Analysis X

10 CFR Part 55 Content:

55.41 X

55.43 Comments: Knowledge of the effect or a loss or malfunction on the following RCS components:

Reactor vessel level indication.

NUREG-1021, Revision 9

ES-401 Written Examination Question Worksheet Form-401-5 RO Grou Examination Outline Cross-reference:

Level SRO Tier #

2 p #

2 K/A #

015.K4.06 Importance Rating 3.9 Proposed Question:

RO# 58, SEE ATTACHED Proposed Answer:

A Technical Reference(s):

Explanation (Optional):

SEE ATTACHED SOP-IC-001 WHITE, Removing Sensors from Service (Attach if not previously provided)

Proposed references to be provided to applicants during examination:

N/A Learning Objective:

053.01.LP2416.011 (As available)

Question Source:

Bank #

INPO 26799 Modified Bank (Note changes or attach parent)

New Question History:

Last NRC Exam Kewaunee, 2/2/2004 (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question)

Question Cognitive Level:

Memory or Fundamental Knowledge Comprehension or Analysis X

10 CFR Part 55 Content:

55.41 X

55.43 Comments: Knowledge of NIS design feature(s) and/or interlock(s) provide for the following:

Reactor trip bypasses.

NUREG-1021, Revision 9

ES-401 Written Examination Question Worksheet Form-401-5 RO Grou Examination Outline Cross-reference:

Level SRO Tier #

2 p #

2 K/A #

016.A2.03 Importance Rating 3.0 Proposed Question:

RO# 59, SEE ATTACHED Proposed Answer:

C Technical Reference(s):

Explanation (Optional):

SEE ATTACHED LOGIC SH. 7, Safeguards Actuation Signals (Attach if not previously provided)

Proposed references to be provided to applicants during examination:

N/A Learning Objective:

055.03.LP3455.001 (As available)

Question Source:

Bank #

Modified Bank (Note changes or attach parent)

New X

Question History:

Last NRC Exam (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question)

Question Cognitive Level:

Memory or Fundamental Knowledge Comprehension or Analysis X

10 CFR Part 55 Content:

55.41 X

55.43 X

Comments: Ability to (a) predict the impacts of the following malfunctions or operations on the NNIS; and (b) based on those predictions, use procedures to correct, control, or mitigate the consequences of those malfunctions or operations: Interruption of transmitted signal.

NUREG-1021, Revision 9

ES-401 Written Examination Question Worksheet Form-401-5 RO Grou Examination Outline Cross-reference:

Level SRO Tier #

2 p #

2 K/A #

017.A1.01 Importance Rating 3.7 Proposed Question:

RO# 60, SEE ATTACHED Proposed Answer:

A Technical Reference(s):

Explanation (Optional):

SEE ATTACHED STM TABLES (Attach if not previously provided)

Proposed references to be provided to applicants during examination:

Steam Tables Learning Objective:

031.02.LP0407.007 (As available)

Question Source:

Bank #

Modified Bank X 19528 (Note changes or attach parent)

New Question History:

Last NRC Exam Cook, 5/21/2001 (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question)

Question Cognitive Level:

Memory or Fundamental Knowledge Comprehension or Analysis X

10 CFR Part 55 Content:

55.41 X

55.43 Comments: Ability to predict and/or monitor changes in parameters (to prevent exceeding design limits) associated with operating the ITM system controls including: Core exit temperature.

NUREG-1021, Revision 9

ES-401 Written Examination Question Worksheet Form-401-5 RO Grou Examination Outline Cross-reference:

Level SRO Tier #

2 p #

2 K/A #

045.K5.01 Importance Rating 2.8 Proposed Question:

RO# 61, SEE ATTACHED Proposed Answer:

A Technical Reference(s):

Explanation (Optional):

SEE ATTACHED LP004, Generator Gas System Lesson Plan (Attach if not previously provided)

Proposed references to be provided to applicants during examination:

N/A Learning Objective:

052.04.LP0004.001 (As available)

Question Source:

Bank #

Modified Bank (Note changes or attach parent)

New X

Question History:

Last NRC Exam (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question)

Question Cognitive Level:

Memory or Fundamental Knowledge X

Comprehension or Analysis 10 CFR Part 55 Content:

55.41 X

55.43 Comments: Knowledge of the operational implications of the following concepts as they apply to the MT/G System: Possible presence of explosive mixture in generator if hydrogen purity deteriorates.

NUREG-1021, Revision 9

ES-401 Written Examination Question Worksheet Form-401-5 RO Tier Grou Examination Outline Cross-reference:

Level SRO 2

p #

2 K/A #

055.K3.01 Importance Rating 2.5 Proposed Question:

Proposed Answer:

D RO# 62, SEE ATTACHED Technical Reference(s):

Explanation (Optional):

SEE ATTACHED TRHB 39.2, Heat Transfer Applications (Attach if not previously provided)

Proposed references to be provided to applicants during examination:

Learning Objective:

055.03.LP2439.004 N/A (As available)

Question Source:

Bank #

Modified Bank (Note changes or attach parent)

New X

Question History:

Last NRC Exam (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question)

Question Cognitive Level:

Memory or Fundamental Knowledge Comprehension or Analysis X

55.41 10 CFR Part 55 Content:

X 55.43 Comments: Knowledge of the effect that a loss or malfunction of the CARS will have on the following: Main condenser.

NUREG-1021, Revision 9

ES-401 Written Examination Question Worksheet Form-401-5 Examination Outline Cross-reference:

RO Tier Grou Level SRO 2

p #

2 K/A #

071.K1.04 Importance Rating 2.7 Proposed Question:

Proposed Answer:

A RO# 63, SEE ATTACHED Technical Reference(s):

Explanation (Optional):

SEE ATTACHED RMS ARBfor RE-214/OP-9C, Discharge of Gas Decay Tank (Attach if not previously provided)

Proposed references to be provided to applicants during examination:

Learning Objective:

051.04.LP0052.004 N/A (As available)

Question Source:

Bank #

INPO 19396 Modified Bank (Note changes or attach parent)

New Question History:

Last NRC Exam Kewaunee, 9/6/2002 (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question)

Question Cognitive Level:

Memory or Fundamental Knowledge X

Comprehension or Analysis 55.41 10 CFR Part 55 Content:

X 55.43 Comments: Knowledge of the physical connections and/or cause-effect relationships between the Waste Gas Disposal System and the following systems: Station ventilation.

NUREG-1021, Revision 9

ES-401 Written Examination Question Worksheet Form-401-5 Examination Outline Cross-reference:

RO Tier Grou Level SRO 2

p #

2 K/A #

075.K2.03 Importance Rating 2.6 Proposed Question:

Proposed Answer:

B RO# 64, SEE ATTACHED Technical Reference(s):

Explanation (Optional):

SEE ATTACHED LOGIC SH. 8, Safeguards Sequence (Attach if not previously provided)

Proposed references to be provided to applicants during examination:

Learning Objective:

051.06.LP0086.008 N/A (As available)

Question Source:

Bank #

Modified Bank (Note changes or attach parent)

New X

Question History:

Last NRC Exam (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question)

Question Cognitive Level:

Memory or Fundamental Knowledge Comprehension or Analysis X

55.41 10 CFR Part 55 Content:

X 55.43 Comments: Knowledge of bus power supplies to the following: Emergency/essential SWS pumps.

NUREG-1021, Revision 9

ES-401 Written Examination Question Worksheet Form-401-5 Examination Outline Cross-reference:

RO Tier Grou Level SRO 2

p #

2 K/A #

086.A4.03 Importance Rating 3.5 Proposed Question:

Proposed Answer:

A RO# 65, SEE ATTACHED Technical Reference(s):

Explanation (Optional):

SEE ATTACHED MCB Photograph (Attach if not previously provided)

Proposed references to be provided to applicants during examination:

Learning Objective:

052.01.LP0003.007 N/A (As available)

Question Source:

Bank #

Modified Bank (Note changes or attach parent)

New X

Question History:

Last NRC Exam (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question)

Question Cognitive Level:

Memory or Fundamental Knowledge X

Comprehension or Analysis 55.41 10 CFR Part 55 Content:

X 55.43 Comments: Ability to manually operate and/or monitor in the control room: Fire alarm switch.

NUREG-1021, Revision 9

ES-401 Written Examination Question Worksheet Form-401-5 Examination Outline Cross-reference:

RO Tier Grou Level SRO 3

p #

K/A #

2.1.10 Importance Rating 2.7 Proposed Question:

Proposed Answer:

B RO# 66, SEE ATTACHED Technical Reference(s):

Explanation (Optional):

SEE ATTACHED TS 3.4.13, RCS Operational Leakage/TS 1.1 Definitions (Attach if not previously provided)

Proposed references to be provided to applicants during examination:

Learning Objective:

057.02.LP3339.001 N/A (As available)

Question Source:

Bank #

INPO 24 Modified Bank (Note changes or attach parent)

New Question History:

Last NRC Exam Braidwood, 6/17/1999 (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question)

Question Cognitive Level:

Memory or Fundamental Knowledge Comprehension or Analysis X

55.41 10 CFR Part 55 Content:

55.43 X

Comments: Knowledge of conditions and limitations in the facility license.

NUREG-1021, Revision 9

ES-401 Written Examination Question Worksheet Form-401-5 Examination Outline Cross-reference:

RO Tier Grou Level SRO 3

p #

K/A #

2.1.31 Importance Rating 4.2 Proposed Question:

Proposed Answer:

B RO# 67, SEE ATTACHED Technical Reference(s):

Explanation (Optional):

SEE ATTACHED 0-SOP-IC-001 RED, Removing Sensors from Service (Attach if not previously provided)

Proposed references to be provided to applicants during examination:

Learning Objective:

053.06.LP0486.017 N/A (As available)

Question Source:

Bank #

Modified Bank (Note changes or attach parent)

New X

Question History:

Last NRC Exam (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question)

Question Cognitive Level:

Memory or Fundamental Knowledge Comprehension or Analysis X

55.41 10 CFR Part 55 Content:

55.43 Comments: Ability to locate control room switches, controls and indications and to determine that they are correctly reflecting the desired plant lineup.

NUREG-1021, Revision 9

ES-401 Written Examination Question Worksheet Form-401-5 Examination Outline Cross-reference:

RO Tier Grou Level SRO 3

p #

K/A #

2.1.23 Importance Rating 3.9 Proposed Question:

Proposed Answer:

B RO# 68, SEE ATTACHED Technical Reference(s):

Explanation (Optional):

SEE ATTACHED OP-1A, Cold Shutdown to Hot Standby (Attach if not previously provided)

Proposed references to be provided to applicants during examination:

Learning Objective:

055.02.LP0162.002 N/A (As available)

Question Source:

Bank #

Modified Bank (Note changes or attach parent)

New X

Question History:

Last NRC Exam (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question)

Question Cognitive Level:

Memory or Fundamental Knowledge Comprehension or Analysis X

55.41 10 CFR Part 55 Content:

55.43 Comments: Ability to perform specific system and integrated plant procedures during all modes of plant operation.

NUREG-1021, Revision 9

ES-401 Written Examination Question Worksheet Form-401-5 Examination Outline Cross-reference:

Grou Level RO SRO Tier #

3 p #

K/A #

2.2.30 Importance Rating 3.5 Proposed Question:

Proposed Answer:

A RO# 69, SEE ATTACHED Explanation (Optional):

SEE ATTACHED Technical Reference(s):

RP-1C, Refueling (Attach if not previously provided)

Proposed references to be provided to applicants during examination:

Learning Objective:

055.02.LP2186.001 N/A (As available)

Question Source:

Bank #

INPO 23017 Modified Bank (Note changes or attach parent)

New Question History:

Last NRC Exam Prairie Island, 8/16/2002 (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question)

Question Cognitive Level:

Memory or Fundamental Knowledge X

Comprehension or Analysis 55.41 10 CFR Part 55 Content:

55.43 Comments: Knowledge of RO duties in the control room during fuel handling such as alarms from fuel handling area, communication with fuel storage facility, systems operated from the control room in support of fueling operations, and supporting instrumentation.

NUREG-1021, Revision 9

ES-401 Written Examination Question Worksheet Form-401-5 Examination Outline Cross-reference:

Grou Level RO SRO Tier #

3 p #

K/A #

2.2.28 Importance Rating 2.6 Proposed Question:

Proposed Answer:

B RO# 70, SEE ATTACHED Explanation (Optional):

SEE ATTACHED Technical Reference(s):

RP-1C, Refueling (Attach if not previously provided)

Proposed references to be provided to applicants during examination:

Learning Objective:

055.02.LP2186.001 N/A (As available)

Question Source:

Bank #

INPO 23466 Modified Bank (Note changes or attach parent)

New Question History:

Last NRC Exam Indian Point 3, 3/10/2003 (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question)

Question Cognitive Level:

Memory or Fundamental Knowledge Comprehension or Analysis X

55.41 10 CFR Part 55 Content:

X 55.43 Comments: Knowledge of new and spent fuel movement procedures.

NUREG-1021, Revision 9

ES-401 Written Examination Question Worksheet Form-401-5 Examination Outline Cross-reference:

Grou Level RO SRO Tier #

3 p #

K/A #

2.3.11 Importance Rating 2.7 Proposed Question:

Proposed Answer:

A RO# 71, SEE ATTACHED Explanation (Optional):

SEE ATTACHED Technical Reference(s):

EOP-3, Steam Generator Tube Rupture (Attach if not previously provided)

Proposed references to be provided to applicants during examination:

Learning Objective:

057.02.LP3339.001 N/A (As available)

Question Source:

Bank #

Modified Bank (Note changes or attach parent)

New X

Question History:

Last NRC Exam (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question)

Question Cognitive Level:

Memory or Fundamental Knowledge X

Comprehension or Analysis 55.41 10 CFR Part 55 Content:

55.43 Comments: Ability to control radiation releases.

NUREG-1021, Revision 9

ES-401 Written Examination Question Worksheet Form-401-5 Examination Outline Cross-reference:

Grou Level RO SRO Tier #

3 p #

K/A #

2.3.01 Importance Rating 2.6 Proposed Question:

Proposed Answer:

C RO# 72, SEE ATTACHED Technical Reference(s):

Explanation (Optional):

SEE ATTACHED 10CFR20 as listed in Radiation Worker Training Materials (Attach if not previously provided)

Proposed references to be provided to applicants during examination:

Learning Objective:

RWT 18 N/A (As available)

Question Source:

Bank #

INPO 14893 Modified Bank (Note changes or attach parent)

New Question History:

Last NRC Exam Vogtle, 12/21/1999 (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question)

Question Cognitive Level:

Memory or Fundamental Knowledge Comprehension or Analysis X

55.41 10 CFR Part 55 Content:

X 55.43 X

Comments: Knowledge of 10 CFR: 20 and related facility radiation control requirements.

NUREG-1021, Revision 9

ES-401 Written Examination Question Worksheet Form-401-5 Examination Outline Cross-reference:

Grou Level RO SRO Tier #

3 p #

K/A #

2.3.09 Importance Rating 2.5 Proposed Question:

Proposed Answer:

C RO# 73, SEE ATTACHED Technical Reference(s):

Explanation (Optional):

SEE ATTACHED RMS ARB for 2RE-212/ARB for Containment Vent Isolation (Attach if not previously provided)

Proposed references to be provided to applicants during examination:

Learning Objective:

053.06.LP0486.020 N/A (As available)

Question Source:

Bank #

Modified Bank (Note changes or attach parent)

New X

Question History:

Last NRC Exam (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question)

Question Cognitive Level:

Memory or Fundamental Knowledge Comprehension or Analysis X

55.41 10 CFR Part 55 Content:

55.43 X

Comments: Knowledge of the process for performing a containment purge.

NUREG-1021, Revision 9

ES-401 Written Examination Question Worksheet Form-401-5 Examination Outline Cross-reference:

Grou Level RO SRO Tier #

3 p #

K/A #

2.4.03 Importance Rating 3.5 Proposed Question:

Proposed Answer:

A RO# 74, SEE ATTACHED Technical Reference(s):

Explanation (Optional):

SEE ATTACHED TS 3.3.3-1, Post-Accident Monitoring Instrumentation (Attach if not previously provided)

Proposed references to be provided to applicants during examination:

Learning Objective:

057.02.LP3341.001 N/A (As available)

Question Source:

Bank #

Modified Bank X 17130 (Note changes or attach parent)

New Question History:

Last NRC Exam Salem, 1/23/1998 (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question)

Question Cognitive Level:

Memory or Fundamental Knowledge X

Comprehension or Analysis 55.41 10 CFR Part 55 Content:

X 55.43 Comments: Ability to identify post-accident instrumentation.

NUREG-1021, Revision 9

ES-401 Written Examination Question Worksheet Form-401-5 Examination Outline Cross-reference:

Grou Level RO SRO Tier #

3 p #

K/A #

2.4.45 Importance Rating 3.3 Proposed Question:

Proposed Answer:

B RO# 75, SEE ATTACHED Technical Reference(s):

Explanation (Optional):

SEE ATTACHED EOP-1.3, Transfer to Sump Recirculation/STPT 11.1, SI Alarms (Attach if not previously provided)

Proposed references to be provided to applicants during examination:

Learning Objective:

043.03.LP1997.009 N/A (As available)

Question Source:

Bank #

Modified Bank X 19487 (Note changes or attach parent)

New Question History:

Last NRC Exam Kewaunee, 12/11/2000 (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question)

Question Cognitive Level:

Memory or Fundamental Knowledge Comprehension or Analysis X

55.41 10 CFR Part 55 Content:

55.43 X

Comments: Ability to prioritize and interpret the significance of each annunciator or alarm.

NUREG-1021, Revision 9