December 2005 Monthly Operating Report for Donald C. Cook Units 1 & 2
ML060250385
Person / Time
Site: Cook  
Issue date: 01/13/2006
From: Jensen J
Indiana Michigan Power Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
AEP:NRC:2691-62
Download: ML060250385 (8)


Text

INDIANA MICHIGAN POWER Indiana Michigan Power Company Nuclear Generation Group One Cook Place Bridgman, MI 49106 aep.com January 13, 2006 Docket Nos.

50-315 50-316 U. S. Nuclear Regulatory Commission Attn: Document Control Desk Mail Stop O-P1-17 Washington, DC 20555-0001 AEP:NRC:2691-62 Donald C. Cook Nuclear Plant Units 1 and 2 MONTHLY OPERATING REPORT In accordance with the requirements of Donald C. Cook Nuclear Plant Unit 1 and Unit 2 Technical Specification 5.6.4, the attached Monthly Operating Report for December 2005 is submitted.

There are no new commitments associated with this submittal.

Should you have any questions, please contact Mr. Michael K. Scarpello, Regulatory Affairs Supervisor, at (269) 466-2649.

Sincerely, Io*eph N. Jensen Site Vice President JEN/jen Attachment

$;2~LI

U. S. Nuclear Regulatory Commission AEP:NRC:269 1-62 Page 2 c: R. Aben - Department of Labor and Economic Growth ANI Nuclear Engineering Department L. Brandon - MDEQ - WHMD/RPMWS D. P. Fadel G. T. Gaffrey - Canton R. A. F. Harris INPO Records Center J. N. Jensen J. T. King - MPSC B. Lewis - McGraw-Hill Companies R. D. Lingle D. H. Malin K. L. Matheny M. K. Nazar NRC Project Manager - NRR NRC Region III NRC Resident Inspector D. W. Paul - Columbus M. A. Peifer W. H. Schalk S. D. Simpson L. J. Weber J. A. Zwolinski

N.R.C. OPERATING DATA REPORT DOCKET NO.

50-315 DATE 1/5/2006 COMPLETED BY R. Harris TELEPHONE 269-465-5901 OPERATING STATUS

1. Unit Name D. C. Cook Unit 1 Notes:
2. Reporting Period Dec-05
3. Licensed Thermal Power (MWt) 3304
4. Name Plate Rating (Gross MWe) 1152
5. Design Electrical Rating (Net MWe) 1020
6. Maximum Dependable Capacity(GROSS MWe) 1056
7. Maximum Dependable Capacity (Net MWe) 1000
8. If Changes Occur in Capacity Ratings (Items no. 3 through 7) Since Last Report Give Reasons
9. Power Level To Which Restricted. If Any (Net MWe)
10. Reasons For Restrictions.

This Mlo.

11. Hours in Reporting Period 744.0
12. No. of Hrs. Reactor Was Critical 744.0
13. Reactor Reserve Shutdown Hours 0.0
14. Hours Generator on Line 744.0
15. Unit Reserve Shutdown Hours 0.0
16. Gross Therm. Energy Gen. (MWH) 2455442.6
17. Gross Elect. Energy Gen. (MWH) 800850.0
18. Net Elect. Energy Gen. (MWH) 774374.0
19. Unit Service Factor 100.0
20. Unit Availability Factor 100.0
21. Unit Capacity Factor (MDC Net) 104.1
22. Unit Capacity Factor (DER Net) 102.0
23. Unit Forced Outage Rate 0.0
24. Shutdowns Scheduled over Next Six Months (Type,Date,and Duration):

Yr. to Date 8760.0 8000.4 0.0 7942.1 0.0 25990756.6 8336729.0 8055846.7 90.7 90.7 92.0 90.2 0.3 Cumm.

271752.0 190501.6 463.0 187710.6 321.0 565662814.6 183513452.0 176732608.4 69.5 69.5 66.4 65.1 17.7

25. If Shut Down At End of Report Period, Est'd Date of Startup:
26. Units in Test Status (Prior to Commercial Operation):

Forecast Achieved INITIAL CRITICALITY INITIAL ELECTRICITY COMMERCIAL OPERATION Page 1 of 6

AVERAGE DAILY POWER LEVEL (MWe-Net)

DOCKET NO.

UNIT DATE COMPLETED BY TELEPHONE 50-315 ONE 05-Jan-06 R. Harris 269-465-5901 MONTH Dec-os AVERAGE DAILY POWER LEVEL DAY DAY 12/1/2005 12/2/2005 12/3/2005 12/4/2005 12/5/2005 12/6/2005 12/7/2005 12/8/2005 12/9/2005 12/10/2005 12/11/2005 12/12/2005 12/13/2005 12/14/2005 12/15/2005 12/16/2005 1035 1042 1042 1041 1037 1043 1037 1044 1039 1041 1038 1060 1026 1035 1045 1037 12/17/2005 12/18/2005 12/19/2005 12/20/2005 12/21/2005 12/22/2005 12/23/2005 12/24/2005 12/25/2005 12/26/2005 12/27/2005 12/28/2005 12/29/2005 12/30/2005 12/31/2005 AVERAGE DAILY POWER LEVEL 1042 1044 1037 1037 1035 1041 1082 1009 1034 1048 1039 1042 1036 1042 1055 Page 2 of 6

DOCKET NO.

UNIT NAME DATE COMPLETED BY TELEPHONE PAGE 50 - 315 Donald C. Cook Nuclear Plant Unit 1 January 5, 2006 J. Newmiller 269-465-5901 3 of 6 UNIT SHUTDOWNS AND POWER REDUCTIONS - December 2005 METHOD OF SHUTTING LICENSEE DURATION DOWN EVENT SYSTEM COMPONENT CAUSE AND CORRECTIVE ACTION NO.

DATE TYPE1 HOURS REASON 2 REACTOR3 REPORT NO.

CODE 4 CODE5 TO PREVENT RECURRENCE None 1 TYPE:

F: Forced S: Scheduled 2 REASON:

A: Equipment Failure (Explain)

B: Maintenance or Test C: Refueling D: Regulatory Restriction E: Operator Training and License Examination F: Administrative G: Operational Error (Explain)

H: Other (Explain) 3 METHOD:

1: Manual 2: Manual Scram 3: Automatic Scram 4: Other (Explain) 4 SYSTEM:

Exhibit G - Instructions for preparation of data entry sheets for Licensee Event Report (LER) File (NUREG 0161) 5 COMPONENT:

Exhibit l: Same Source

N.R.C. OPERATING DATA REPORT DOCKET NO.

50-316 DATE 1/5/2006 COMPLETED BY R. Harris TELEPHONE 269-465-5901 OPERATING STATUS

1. Unit Name D. C. Cook Unit 2 Notes:
2. Reporting Period Dec-05
3. Licensed Thermal Power (MWt) 3468
4. Name Plate Rating (Gross MWe) 1133
5. Design Electrical Rating (Net MWe) 1090
6. Maximum Dependable Capacity(GROSS MWe) 1100
7. Maximum Dependable Capacity (Net MWe) 1060
8. If Changes Occur in Capacity Ratings (Items no. 3 through 7) Since Last Report Give Reasons
9. Power Level To Which Restricted. If Any (Net MWe)
10. Reasons For Restrictions.

This Mo.

Yr. to Date Cumm.

11. Hours in Reporting Period 744.0 8760.0 245898.0
12. No. of Hrs. Reactor Was Critical 744.0 8644.6 164393.8
13. Reactor Reserve Shutdown Hours 0.0 0.0 0.0
14. Hours Generator on Line 744.0 8604.1 160366.4
15. Unit Reserve Shutdown Hours 0.0 0.0 0.0
16. Gross Therm. Energy Gen. (MWH) 2577551.2 29685272.7 508567610.5
17. Gross Elect. Energy Gen. (MWH) 855930.0 9720540.0 165036108.0
18. Net Elect. Energy Gen. (MWH) 829514.0 9415536.0 159218950.6
19. Unit Service Factor 100.0 98.2 65.8
20. Unit Availability Factor 100.0 98.2 65.8
21. Unit Capacity Factor (MDC Net) 105.2 101.4 62.2
22. Unit Capacity Factor (DER Net) 102.3 98.6 60.5
23. Unit Forced Outage Rate 0.0 1.0 21.7
24. Shutdowns Scheduled over Next Six Months (Type,Date,and Duration):

Scheduled Refueling Outage - March 2006

25. If Shut Down At End of Report Period, Estd Date of Startup:
26. Units in Test Status (Prior to Commercial Operation):

Forecast Achieved INITIAL CRITICALITY INITIAL ELECTRICITY COMMERCIAL OPERATION Page 4 of 6

AVERAGE DAILY POWER LEVEL (MWe-Net)

DOCKET NO.

UNIT DATE COMPLETED BY TELEPHONE 50-316 TWO 5-Jan-06 R. Harris 269-465-5901 MONTH Dec-05 AVERAGE DAILY POWER LEVEL DAY DAY 12/1/2005 12/2/2005 12/3/2005 12/4/2005 12/5/2005 12/6/2005 12/7/2005 12/8/2005 12/9/2005 12/10/2005 12/11/2005 12/12/2005 12/13/2005 12/14/2005 12/15/2005 12/16/2005 1120 1113 1116 1109 1117 1118 1116 1112 1111 1117 1118 1125 1118 1106 1107 1112 12/17/2005 12/18/2005 12/19/2005 12/20/2005 12/21/2005 12/22/2005 12/23/2005 12/24/2005 12/25/2005 12/26/2005 12/27/2005 12/28/2005 12/29/2005 12/30/2005 12/31/2005 AVERAGE DAILY POWER LEVEL 1127 1148 1071 1120 1106 1117 1115 1121 1115 1119 1110 1111 1115 1112 1123 Page 5 of 6

DOCKET NO.

UNIT NAME DATE COMPLETED BY TELEPHONE PAGE 50 - 316 Donald C. Cook Nuclear Plant Unit 2 January 5, 2006 J. Newmiller 269-465-5901 6 of 6 UNIT SHUTDOWNS AND POWER REDUCTIONS - December 2005 METHOD OF SHUTTING LICENSEE DURATION DOWN EVENT SYSTEM COMPONENT CAUSE AND CORRECTIVE ACTION NO.

DATE TYPE' HOURS REASON 2 REACTOR 3 REPORT NO.

CODE4 CODE5 TO PREVENT RECURRENCE None 1 TYPE:

F: Forced S: Scheduled 2 REASON:

A: Equipment Failure (Explain)

B: Maintenance or Test C: Refueling D: Regulatory Restriction E: Operator Training and License Examination F: Administrative G: Operational Error (Explain)

H: Other (Explain) 3 METHOD:

1: Manual 2: Manual Scram 3: Automatic Scram 4: Other (Explain) 4 SYSTEM:

Exhibit G - Instructions for preparation of data entry sheets for Licensee Event Report (LER) File (NUREG 0161) 5 COMPONENT:

Exhibit l: Same Source