Tech Spec Pages for Amendments 270 and 251 Regarding Elimination of Requirements to Provide Monthly Operating Reports and Annual Occupational Radiation Exposure Reports
ML060170380
Person / Time
Site: Salem  
(DPR-070, DPR-075)
Issue date: 01/11/2006
From:
Plant Licensing Branch III-2
To:
References
TAC MC5662, TAC MC5663
Download: ML060170380 (2)


Text

ADMINISTRATIVE CONTROLS 6.9.1.5 Reports required on an annual basis shall include:

a.

DELETED

b.

The complete results of steam generator tube inservice inspections performed during the report period (reference Specification 4.4.5.5.b).

c.

The results of any specific activity analyses in which the primary coolant exceeded the limits of Specification 3.4.8.

The following information shall be included:

(1) Reactor power history starting 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> prior to the first sample in which the limit was exceeded; (2) Results of the last isotopic analysis for radioiodine performed prior to exceeding the limit, results of analysis while the limit was exceeded and results of one analysis after the radioiodine activity was reduced to less than the limit. Each result should include date and time of sampling and the radioiodine concentrations; (3) Clean-up system flow history starting 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> prior to the first sample in which the limit was exceeded; (4)

Graph of the I-131 concentration and one other radioiodine isotope concentration in microcuries per gram as a function of time for the duration of the specific activity above the steady state level; and (5) The time duration when the specific activity of the primary coolant exceeded the radioiodine limit.

MONTHLY OPERATING REPORT 6.9.1.6 DELETED SALEM -

UNIT 1 6-21 Amendment No. 270

ADMINISTRATIVE CONTROLS 6.9.1.5 Reports required on an annual basis shall include:

a.

Deleted

b.

The complete results of steam generator tube inservice inspections performed during the report period (reference Specification 4.4.5.5.b).

c.

The results of any specific activity analyses in which the primary coolant exceeded the limits of Specification 3.4.8.

The following information shall be included:

(1) Reactor power history starting 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> prior to the first sample in which the limit was exceeded; (2) Results of the last isotopic analysis for radioiodine performed prior to exceeding the limit, results of analysis while the limit was exceeded and results of one analysis after the radioiodine activity was reduced to less than the limit. Each result should include date and time of sampling and the radioiodine concentrations; (3) Clean-up system flow history starting 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> prior to the first sample in which the limit was exceeded; (4)

Graph of the I-131 concentration and one other radioiodine isotope concentration in microcuries per gram as a function of time for the duration of the specific activity above the steady state level; and (5) The time duration when the specific activity of the primary coolant exceeded the radioiodine limit.

MONTHLY OPERATING REPORT 6.9.1.6 DELETED.

SALEM - UNIT 2 6-21 Amendment No.251 I