ATTACHMENT C ASME Form NIS-BB TUBE EXAMINATION REPORT Page 24 of 31
Attachment C.1 SG A ASME Form NIS-BB Page 25 of 31
ATTACHMENT C ASME Form NIS-BB TUBE EXAMINATION REPORT Page 24 of 31
Attachment C.1 SG A ASME Form NIS-BB Page 25 of 31
ATTACHMENT C.1 ASME SECTION XI FORM NIS-BB 2A Steam Generator Page 1 of 4 EDDY CURRENT EXAMINATION RESULTS - REFUEL OUTAGE 12 Site: Byron Station, Unit 2 Steam Generator: 2RCOIBA Test Frequency: 20, 130, 300, 500 kHz Date:
10/5/2005
- 20, 100, 200, 300 kHz
% Tube_Wall Row Column Penetration Origin Location Inch 20 64 20 AV1 OD 0.26 22 109 12 AV4 OD 0
23 109 15 AV1 OD 0
23 109 15 AV4 OD
-0.06 25 8
24 AV3 OD 0
26 107 12 AV2 OD
-0.08 26 107 18 AV3 OD
-0.17 27 18 19 AV1 OD 0
27 85 30 AV2 OD 0
27 104 20 AV2 OD
-0.05 27 106 27 AV1 OD 0
27 106 24 AV2 OD 0
27 106 32 AV3 OD 0
28 105 17 AV3 OD
-0.03 28 105 18 AV4 OD 0
29 10 34 AV3 OD 0
29 12 15 AV2 OD 0.31 29 12 20 AV3 OD
-0.13 29 13 17 AV3 OD 0
29 34 15 AV3 OD
-0.15 29 104 15 AV3 OD 0
30 69 15 AV2 OD 0
30 69 16 AV3 OD
-0.21 30 103 19 AV2 OD 0.11 30 104 15 AV2 OD 0
31 12 20 AV3 OD
-0.15 31 12 17 AV4 OD 0
31 14 19 AV3 OD 0
31 14 16 AV4 OD
-0.08 31 67 21 AV4 OD 0
31 101 20 AV2 OD 0.13 31 101 26 AV3 OD
-0.16 31 103 18 AV2 OD 0.21 31 103 20 AV3 OD
-0.37 32 76 15 AV3 OD 0
32 79 21 AV4 OD
-0.05 34 14 24 AV2 OD 0.08 34 90 17 AV3 OD 0
35 15 21 AV3 OD
-0.08 35 15 14 AV4 OD 0
35 16 25 AV2 OD 0.03 35 16 20 AV3 OD 0.13 35 16 15 AV4 OD 016 35 100 15 AV3 OD 0.11 36 15 13 AV3 OD 0.11 Page 1 of 4
ATTACHMENT C~1 ASME SECTION XI FORM NIS-BB 2A Steam Generator Page 2 of 4 EDDY CURRENT EXAMINATION RESULTS - REFUEL OUTAGE 12 Site: Byron Station, Unit 2 Steam Generator: 2RCOIBA Test Frequency: 20, 130, 300, 500 kHz Date:
10/5/2005
- 20, 100, 200, 300 kHz
%_Tube Wall Row Column Penetration Origin Location Inch 36 15 16 AV4 OD
-003 36 18 19 AV2 OD 0
36 18 19 AV3 OD 0.05 36 21 20 AV3 OD 0.08 36 21 15 AV4 OD 0.08 36 95 14 AV3 OD 0
36 96 19 AV2 OD
-0.08 37 16 16 AV4 OD
-0.05 37 17 27 AV3 OD 0
37 18 15 AV2 OD 0
37 18 15 AV4 OD 0.05 37 19 15 AV1 OD 0.17 37 19 20 AV3 OD
-0.03 37 20 20 AV3 OD 0.03 37 21 20 AV3 OD 0.03 37 23 26 AV2 OD 0
37 23 27 AV3 OD 0
37 23 15 AV4 OD
-0.05 37 98 29 AV2 OD 0
37 98 30 AV3 OD 0.03 37 99 21 AV3 OD
-0.11 38 16 22 AV3 OD 0
38 16 19 AV4 OD 0
38 19 20 AV3 OD 0
38 19 24 AV4 OD 0
38 20 25 AV1 OD 0
38 20 25 AV2 OD 0.05 38 20 19 AV4 OD 0.05 38 21 19 AV1 OD 003 38 21 18 AV3 OD 0.03 38 22 19 AV2 OD 0
38 23 24 AV1 OD 0
38 23 16 AV2 OD 0.15 38 23 30 AV3 OD 0
38 23 26 AV4 OD 0
38 24 19 AV2 OD 0
38 24 14 AV3 OD 0.08 38 26 16 AV2 OD 0
38 27 18 AV3 OD 0.06 38 30 22 AV3 OD 0.03 38 34 18 AV3 OD 0
38 63 11 AV2 OD 0
38 63 15 AV4 OD 0.11 38 72 24 AV3 OD 0
38 72 15 AV4 OD 0
Page 2 of 4
ATTACHMENT C.1 ASME SECTION XI FORM NIS-BB 2A Steam Generator Page 3 of 4 EDDY CURRENT EXAMINATION RESULTS - REFUEL OUTAGE 12 Site: Byron Station, Unit 2 Steam Generator: 2RCOIBA Test Frequency: 20, 130, 300, 500 kHz Date:
10/5/2005
- 20, 100, 200, 300 kHz
%_Tube Wall Row Column Penetration Origin Location Inch 38 73 10 AV2 OD
-0.1 38 73 25 AV3 OD
-0.15 38 98 16 AVI OD 0.05 38 98 28 AV2 OD 0.03 38 98 18 AV3 OD 0
39 21 34 AV3 OD 0
39 21 19 AV4 OD 0
39 23 19 AV2 OD 0
39 23 28 AV3 OD 0
39 23 17 AV4 OD 0
39 84 15 AV2 OD 0
39 85 13 AV2 OD 0
39 89 27 AV2 OD
-0.05 39 89 35 AV3 OD
-0.03 39 89 17 AV4 OD 0.08 39 94 17 AVI OD 0.08 39 94 17 AV2 OD
-0.13 39 94 37 AV3 OD 0
39 96 15 AV3 OD 0.13 39 96 13 AV4 OD 0
40 46 26 AV3 OD 0
40 64 15 AV1 OD 0
40 66 15 AV1 OD 0
40 82 22 AV2 OD 0
40 82 16 AV3 OD 0
40 85 17 AV3 OD 0.07 40 90 25 AV2 OD 0
40 90 22 AV3 OD 0
40 90 14 AV4 OD 0
40 91 15 AV2 OD 0.03 40 91 29 AV3 OD 0
40 92 15 AV2 OD 0.1 40 92 13 AV3 OD
-0.05 40 95 22 AV1 OD 0.11 40 95 31 AV2 OD 0.03 40 95 30 AV3 OD 0
40 95 29 AV4 OD 0
41 22 34 AV2 OD 0
41 33 12 AV2 OD 0
41 33 16 AV3 OD 0
41 84 12 AV2 OD 0
41 84 18 AV3 OD 0
41 85 17 AV2 OD 0.02 41 85 20 AV3 OD
-0.05 41 87 33 AV2 OD 0
Page 3 of 4
ATTACHMENT C~1 ASME SECTION XI FORM NIS-BB 2A Steam Generator Page 4 of 4 EDDY CURRENT EXAMINATION RESULTS - REFUEL OUTAGE 12 Site: Byron Station, Unit 2 Steam Generator: 2RCOI BA Test Frequency: 20, 130, 300, 500 kHz Date:
10/5/2005
- 20, 100, 200, 300 kHz
%_Tube Wall Row Column Penetration Origin Location Inch 41 87 17 AV3 OD 0.03 41 87 15 AV4 OD 0
41 88 14 AV2 OD 0
41 91 24 AV2 OD 0
41 41 91 12 AV3 OD 0.05 92 23 AV2 OD 0
41 92 17 AV3 OD
-0.16 41 92 24 AV4 OD 0.24 42 25 16 AV2 OD 0
42 25 35 AV3 OD 0
42 25 22 AV4 OD 0
44 59 17 AV3 OD 0
44 81 32 AV2 OD 0
44 81 19 AV3 OD
-0.13 44 88 10 AV2 OD 0
44 88 24 AV3 OD 0
44 88 22 AV4 OD
-0.16 44 90 18 AV2 OD 0
44 90 30 AV3 OD 0
45 25 20 AV3 OD 0.08 45 25 19 AV4 OD 0.05 45 28 38 AV3 OD 0.03 45 28 35 AV4 OD
-0.1
- 45 67 7
02C OD 1.17
- 45 67 7
46 64 26 AV3 OD 0
46 64 35 AV4 OD 0
47 28 10 AV4 OD
-0.03 47 59 15 AV1 OD 0
47 61 22 AV3 OD
-0.05 47 61 20 AV4 OD
-0.05 48 56 25 AV3 OD 0
48 56 16 AV4 OD 005 Page 4 of 4
Attachment C~2 SG B ASME Form NIS-BB Page 26 of 31
ATTACHMENT C.2 ASME SECTION XI FORM NIS-BB 2B Steam Generator Page 1 of 7 EDDY CURRENT EXAMINATION RESULTS - REFUEL OUTAGE 12 Site: Byron Station, Unit 2 Steam Generator: 2RCOI BB Test Frequency: 20, 130, 300, 500 kHz Date:
10/5/2005
- 20, 100, 200, 300 kHz
%_Tube_Wall Row Column Penetration Origin Location Inch
- 9 5
10 OD 05H 0.75
- 9 6
13 OD 05H 0.76
- 10 5
10 OD 05H 0.7
- 10 6
33 OD 05H 0.69 15 91 6
OD 06C
-0.18 23 106 15 OD AV2
-0.12 23 107 15 OD AV3 0.05 23 108 33 OD AV2 0
23 108 16 OD AV3 0.12 24 106 16 OD AV2 0.02 24 107 13 OD AV2 0.4 24 107 14 OD AV3 0
24 108 25 OD AV4
-0.06 25 91 16 OD AV3
-0.05 25 103 21 OD AV2
-0.1 25 104 21 OD AV2 0.05 25 106 18 OD AV4 0.03 25 107 16 OD AV2 0.47 25 107 21 OD AV3
-0.15 25 108 13 OD AV2
-0.13 25 108 26 OD AV4 0
27 10 16 OD AV2 0.29 27 29 17 OD AV3 0.13 27 31 15 OD AV3
-0.13 27 31 19 OD AV4
-0.08 27 105 15 OD AV1
-0.03 27 105 25 OD AV2 0.08 27 105 15 OD AV3
-0.13 27 105 13 OD AV4
-0.06 28 11 18 OD AV2 0
28 11 30 OD AV3 0.06 28 11 20 OD AV4 0
28 12 17 OD AV2 0.19 28 27 15 OD AV2 0.15 28 27 19 OD AV3
-0.1 28 29 16 OD AV2 0
28 29 17 OD AV3 0.08 28 32 18 OD AV2 0.13 28 37 17 OD AV3 0.12 Page 1 of 7
ATTACHMENT C.2 ASME SECTION XI FORM NIS-BB 2B Steam Generator Page 2 of 7 EDDY CURRENT EXAMINATION RESULTS - REFUEL OUTAGE 12 Site: Byron Station, Unit 2 Steam Generator: 2RCOIBB Test Frequency: 20, 130, 300, 500 kHz Date:
10/5/2005
- 20, 100, 200, 300 kHz
%_Tube_Wall Row Column Penetration Origin Location Inch 28 79 17 OD AV3 0.05 28 99 15 OD AV2 0,05 28 102 26 OD AV3 0
28 103 20 OD AV3
-0.1 28 104 24 OD AV2
-0.03 28 104 22 OD AV3
-0.14 29 13 18 OD AV3
-0.09 29 98 19 OD AV2 0.1 29 105 17 OD AV2 0
29 105 22 OD AV4
-0.19 30 12 15 OD AV2 0.03 30 13 16 OD AV3 0
30 14 15 OD AV3 0.27 30 99 17 OD AV3
-0.03 30 102 30 OD AV2
-0.03 30 102 21 OD AV3
-0.13 30 105 25 OD AV4 0
31 12 20 OD AVI 0.11 31 12 23 OD AV2 0
31
12 29 OD AV3 0
31
12 26 OD AV4 0
31 13 14 OD AV1 0
31 13 12 OD AV2 0
31 13 20 OD AV4 0
31 15 24 OD AV2 0
31 16 15 OD AV3 0.03 31 17 15 OD AV2 0.16 31 17 12 OD AV3 0.11 31 34 16 OD AV3 0.1 31 102 22 OD AV3
-0.05 32 12 24 OD AV2 0.32 32 28 26 OD AV2
-0.08 32 28 20 OD AV3 0.03 32 32 20 OD AV2
-0.03 32 32 29 OD AV3 0.13 32 32 18 OD AV4 0.08 32 36 22 OD AV3
-0.1 32 39 19 OD AV3 0.11 32 39 15 OD AV4 0
32 40 14 OD AV2 0.1 32 40 16 OD AV3 0
32 40 13 OD AV4
-0.05 32 98 23 OD AV3
-0.03 33 13 19 OD AV1 0
33 14 29 OD AVI 0.08 Page 2 of 7
ATTACHMENT C.2 ASME SECTION XI FORM NIS-BB 2B Steam Generator Page 3 of 7 EDDY CURRENT EXAMINATION RESULTS - REFUEL OUTAGE 12 Site: Byron Station, Unit 2 Steam Generator: 2RCOIBB Test Frequency: 20, 130, 300, 500 kHz Date:
10/5/2005
- 20, 100, 200, 300 kHz
%TubeWaII Row Column Penetration Origin Location Inch 33 14 21 OD AV2
-0.08 33 14 15 OD AV3 0.03 33 14 18 OD AV4 0.08 33 72 17 OD AV3
-0.06 33 72 21 OD AV4 0.08 33 97 30 OD AV3 0
33 98 17 OD AV2
-0.08 33 98 24 OD AV3
-0.1 33 99 18 OD AV1
-0.05 33 99 24 OD AV2 0
33 99 22 OD AV3
-0.11 33 99 14 OD AV4 0
34 14 31 OD AV3 0
34 17 17 OD AV3 0
34 19 13 OD AV3 0.08 34 26 21 OD AV3
-0.11 34 30 16 OD AVI 0.13 34 30 23 OD AV3
-0.05 34 33 23 OD AV2 0.11 34 36 18 OD AV2 0.27 34 39 17 OD AV2 0
34 99 15 OD AV3
-0.11 34 100 14 OD AV3 0
34 102 12 OD AV4
-0.05 35 14 17 OD AV1 0
35 14 21 OD AV2 0
35 14 22 OD AV3 0
35 15 29 OD AV2 0
35 16 18 OD AV3
-0.06 35 96 26 OD AV3 0.03 35 97 14 OD AV2 0
35 97 33 OD AV3 0
35 98 24 OD AV1
-0.08 35 98 15 OD AV3
-0.11 35 98 27 OD AV4
-0.06 35 99 21 OD AV3
-0.05 35 99 24 OD AV4 0
35 100 25 OD AV2 0
35 100 16 OD AV3
-0.11 35 100 21 OD AV4
-0.05 35 101 36 OD AV3
-0.06 35 101 30 OD AV4
-0.05 36 16 16 OD AV2
-0.11 36 16 22 OD AV3
-0.17 36 17 18 OD AV2 0
Page 3 of 7
ATTACHMENT C.2 ASME SECTION XI FORM NIS-BB 2B Steam Generator Page 4 of 7 EDDY CURRENT EXAMINATION RESULTS - REFUEL OUTAGE 12 Site: Byron Station, Unit 2 Steam Generator: 2RCOIBB Test Frequency: 20, 130, 300, 500 kHz Date:
10/5/2005
- 20, 100, 200, 300 kHz
%_Tube_Wall Row Column Penetration Origin Location Inch 36 17 15 00 AV3 0
36 18 16 00 AV2
-0.05 36 20 19 00 AV2 0
36 23 22 00 AV2
-0.05 36 29 13 00 AV2 0.1 36 29 15 00 AV3 0.05 36 78 22 OD AV3
-0.05 36 78 15 00 AV4
-0.03 36 88 18 00 AV3 0
36 90 16 00 AV3
-0.1 36 94 21 00 AV2 0
37 17 13 00 AV3 0.31 37 83 19 00 AV2 0.21 37 90 16 00 AV2 0.23 37 92 35 00 AV2 0
37 93 14 00 AV2
.0 37 93 27 00 AV3 0
37 95 16 00 AV2 0
37 95 19 00 AV3 0
37 95 15 00 AV4 0
38 71 17 00 AV1
-0.03 38 71 21 00 AV2 0.25 38 71 31 00 AV3
-0.03 38 92 17 00 AV2 0,11 38 92 16 00 AV3 0.26 38 93 14 00 AV2 0
38 93 17 OD AV3
-0.03 38 93 16 OD AV4 0.03 38 95 33 00 AV1 0
38 95 20 00 AV2 0
38 95 23 OD AV3 0
38 95 26 OD AV4 0
38 96 30 00 AV1 0
38 96 26 00 AV2 0
38 96 17 00 AV3 0.16 38 96 30 OD AV4 0
39 19 29 00 AV2
-0.03 39 19 26 OD AV3
-0.19 39 20 14 OD AV2 0.08 39 21 17 OD AV2
-0.05 39 21 16 OD AV3 0
39 26 19 00 AV2 0.22 39 26 15 OD AV3 0
39 27 11 OD AV3 0.08 39 33 15 00 AV3
-0.08 Page 4 of 7
ATTACHMENT Ci ASME SECTION XI FORM NIS-BB 2B Steam Generator Page 5 of 7 EDDY CURRENT EXAMINATION RESULTS - REFUEL OUTAGE 12 Site: Byron Station, Unit 2 Steam Generator: 2RCOIBB Test Frequency: 20, 130, 300, 500 kHz Date:
10/5/2005
- 20, 100, 200, 300 kHz
%_Tube Wall Row Column Penetration Origin Location Inch 39 33 17 00 AV4 0.13 39 39 19 OD AV2 0
39 69 16 OD AV3
-0.05 39 77 17 OD AV3 0.05 39 88 17 00 AV2 0
39 92 22 00 AV4 0
39 93 22 00 AV3 0
39 93 14 OD AV4 0.05 39 94 21 OD AV2
-0.03 39 94 32 00 AV3
-0.03 39 94 19 OD AV4 0.08 39 95 22 00 AV2 0
39 95 19 OD AV3
-0.03 39 95 21 OD AV4 0
39 96 18 OD AV1
-0.06 39 96 40 OD AV2 0
39 96 17 OD AV4 0
40 18 13 OD AV1
-0.08 40 18 38 OD AV2
-0.03 40 18 38 OD AV3 0.22 40 20 19 OD AV2 0.05 40 20 21 OD AV3 0.14 40 24 18 OD AV2 0.11 40 26 16 OD AV2 0.45 40 27 19 00 AV3
-0.03 40 34 22 00 AV2
-0.03 40 41 17 OD AV2 0
40 45 11 OD AV2 0
40 54 13 OD AV2 0
40 54 15 OD AV3
-0.15 40 59 17 OD AV3
-0.13 40 91 21 00 AV2 0.23 40 92 28 00 AV3 0
40 94 33 00 AV2
-0.03 40 95 15 OD AV3 0
40 95 19 OD AV4 0.03 41 43 21 00 AV1 0.16 41 43 24 OD AV2 0.1 41 43 33 OD AV3 0.08 41 85 16 00 AV2
-0.03 41 87 23 00 AV1
-0.14 41 87 29 OD AV2
-0.06 41 87 23 00 AV3 0
41 87 14 00 AV4 0
41 93 24 00 AV2
-0.03 Page 5 of 7
ATTACHMENT Ci ASME SECTION XI FORM NIS-BB 2B Steam Generator Page 6 of 7 EDDY CURRENT EXAMINATION RESULTS - REFUEL OUTAGE 12 Site: Byron Station, Unit 2 Steam Generator: 2RCOIBB Test Frequency: 20, 130, 300, 500 kHz Date:
10/5/2005
- 20, 100, 200, 300 kHz
%_Tube_Wall Row Column Penetration Origin Location Inch 41 93 27 OD AV3
-0.03 41 93 22 OD AV4 0
41 95 20 00 AV1
-0.05 41 95 34 00 AV2
-0.05 41 95 29 OD AV3
-0.03 42 30 23 00 AV1 0.06 42 30 20 00 AV2 0
42 30 34 OD AV3
-0.05 42 34 15 OD AV2 0,23 42 36 18 OD AV2 0.2 42 37 14 OD AV1 0.08 42 37 23 OD AV2 0
42 37 25 OD AV3 0.05 42 44 12 OD AV2 0.11 42 44 31 00 AV3 0
42 44 16 00 AV4 0.08 42 68 20 OD AV2
-0.08 42 68 18 00 AV3 0.06 42 84 18 00 AV2 0.2 42 84 17 OD AV3 0
42 86 19 00 AV2
-0.17 42 89 34 00 AV1
-0.03 42 89 34 00 AV2 0.1 42 89 27 00 AV3
-0.08 43 25 22 00 AV2
-0.03 43 25 17 00 AV3 0.08 43 25 13 00 AV4 0.16 43 29 16 00 AV1 0.13 43 29 35 OD AV2 0.03 43 29 11 00 AV3 0.27 43 91 24 OD AV3 0
43 92 20 OD AV3 0
43 93 15 OD AV4 0
44 26 29 OD AV2 0
44 26 10 OD AV3 0.16 44 45 16 OD AV2 0.2 44 45 19 OD AV3 0.15 44 76 26 OD AV2 0.03 44 76 21 OD AV3
-0.15 44 76 16 00 AV4
-0.11 44 85 24 OD AV2 0.05 44 85 33 OD AV3
-0.05 44 85 28 OD AV4
-0.09 44 90 31 00 AV3 0
44 90 17 00 AV4 0
Page 6 of 7
ATTACHMENT Ci ASME SECTION XI FORM NIS-BB 2B Steam Generator Page 7 of 7 EDDY CURRENT EXAMINATION RESULTS - REFUEL OUTAGE 12 Site: Byron Station, Unit 2 Steam Generator: 2RCOIBB Test Frequency: 20, 130, 300, 500 kHz Date:
10/5/2005
- 20, 100, 200, 300 kHz
%_Tube_Wall Row Column Penetration Origin Location Inch 45 26 26 OD AV2 0
45 26 33 OD AV3 0
45 26 22 OD AV4
-0.03 45 29 16 OD AV4
-0.05 45 32 17 OD AV2 0.03 45 32 22 OD AV3 0
45 36 22 OD AV3 0.03 45 36 26 OD AV4 0
45 83 27 OD AV2 0.03 45 83 20 OD AV3
-0.1 45 83 19 OD AV4 0.16 45 86 30 OD AV2 0.1 45 86 24 OD AV3 0.14 45 89 33 OD AV2
-0.03 45 89 22 OD AV3
-0.03 46 50 19 OD 07C
-0.05 47 27 33 OD AV2 0
47 27 26 OD AV3 0
47 27 25 OD AV4
-0.11 47 56 23 OD AV2 0
47 75 9
OD 02C 0.1 48 50 36 OD 07C 0.05 48 53 28 OD 07C
-0.05 48 54 26 OD 07C 0.27 48 55 27 OD 07C 0
48 59 31 OD 07C
-0.19 49 50 43 OD 07C
-0.08 49 52 18 OD 07C 0.03 49 53 44 OD 07C 0.11 49 63 29 OD 07C
-0.03 Page 7 of 7
Attachment C.3 SG C ASME Form NIS-BB Page 27 of 31
ATTACHMENT C~3 ASME SECTION XI FORM NIS-BB 2C Steam Generator Page 1 of 5 EDDY CURRENT EXAMINATION RESULTS - REFUEL OUTAGE 12 Site: Byron Station, Unit 2 Steam Generator: 2RCOIBC Test Frequency: 20, 130, 300, 500 kHz Date:
10/5/2005
- 20, 100, 200, 300 kHz
%_Tube Wall Row Column Penetration Origin Location Inch 22 6
16 00 AV1 0
22 6
17 00 AV4 0
23 6
24 00 AV4 0
25 105 17 00 AV2
-0.03 25 106 21 00 AV1 0.15 25 107 20 OD AV4
-0.15 25 108 16 00 AV1 0.1 25 108 21 00 AV2 0
25 108 21 00 AV3 0
26 8
18 OD AV2
-0.32 26 8
15 00 AV3 0.18 26 9
18 00 AV2 0.08 26 9
18 00 AV3 0.11 26 9
22 00 AV4
-0.13 26 18 15 00 AV3 0.12 26 85 16 OD AV2 0.08 27 11 15 00 AV2
-0.27 27 34 15 00 AV3
-0.15 27 106 19 00 AV2
-0.03 27 106 29 00 AV3
-0.23 28 35 16 OD AV3 0
28 35 16 00 AV4 0
28 84 18 00 AV3 0.03 28 103 27 OD AV3
-0.19 29 11 19 00 AV1 0
29 29 18 OD AV2 0
29 29 18 00 AV3 0
29 38 15 00 AV3 0.12 29 40 16 OD AV2
-0.02 29 40 16 00 AV3
-0.05 29 43 21 OD AV4 0
29 44 17 00 AV2 0.09 30 35 21 OD AV3 0
30 84 16 OD AV2 0
30 85 17 OD AV2
-0.11 30 100 12 00 AV2 0.1 30 101 15 00 AV2 0.08 30 101 17 OD AV3
-0.4 30 104 17 00 AV2
-0.03 30 104 18 00 AV3
-0.16 31 14 16 OD AV1 0.06 31 14 19 00 AV3
-0.08 31 36 17 00 AV2
-0.02 31 48 16 00 AV2
-0.1 31 82 15 OD AV3 0.05 Page 1 of 5
ATTACHMENT C~3 ASME SECTION XI FORM NIS-BB 2C Steam Generator Page 2 of 5 EDDY CURRENT EXAMINATION RESULTS - REFUEL OUTAGE 12 Site: Byron Station, Unit 2 Steam Generator: 2RCOI BC Test Frequency: 20, 130, 300, 500 kHz Date:
10/5/2005
- 20, 100, 200, 300 kHz
%_Tube_Wall Row Column Penetration Origin Location Inch 32 13 17 00 AV2 0
32 13 21 00 AV3 0
32 28 15 OD AV2 0
32 28 13 00 AV3 0
32 74 17 00 AV3 0
32 79 15 OD AV3 0
32 82 20 00 AV2
-0.05 32 83 17 00 AV3 0.17 32 101 16 00 AV3
-0.13 33 16 17 OD AV3
-0.14 33 39 14 00 AV2 0
33 39 17 OD AV3 0
33 50 16 00 AV3 0.02 33 81 15 00 AV3
-0.03 34 27 25 00 AV2 0
34 29 17 OD AV2 0
34 29 17 00 AV3 0
34 85 15 00 AV2 0.11 34 85 16 00 AV3
-0.05 34 92 18 00 AV2 0.11 34 94 16 00 AV3 0.08 34 95 17 OD AV2 0
35 18 19 00 AV2 0.38 35 19 15 OD AV2 0
35 22 17 00 AV1 0.21 35 22 24 00 AV3
-0.1 35 25 23 00 AV2 0
35 25 20 00 AV3 0
35 30 21 00 AV2 0.31 35 82 16 OD AV2 0.05 35 82 20 00 AV3 0.05 35 83 15 00 AV3 0.05 35 85 16 OD AV1
-0.13 35 85 22 00 AV2 0.13 35 85 31 OD AV3 0
35 86 15 OD AV1 0.03 35 86 31 OD AV2 0
35 86 16 00 AV3 0.05 35 87 19 00 AV3
-0.08 35 88 19 OD AV3
-0.12 35 93 15 OD AV2
-0.13 35 95 21 00 AV2
-0.05 35 96 15 OD AV2
-0.16 36 19 25 OD AV3 0.08 36 20 18 00 AV3
-0.08 Page 2 of 5
ATTACHMENT C~3 ASME SECTION XI FORM NIS-BB 2C Steam Generator Page 3 of 5 EDDY CURRENT EXAMINATION RESULTS - REFUEL OUTAGE 12 Site: Byron Station, Unit 2 Steam Generator: 2RCOI BC Test Frequency: 20, 130, 300, 500 kHz Date:
10/5/2005
- 20, 100, 200, 300 kHz
%_Tube Wall Row Column Penetration Origin Location Inch 36 21 26 00 AV3 0.02 36 22 19 00 AV2 0.05 36 22 19 OD AV3 0.07 36 24 27 00 AV3
-0.15 36 25 17 00 AV2 0.17 36 27 19 OD AV3 0
36 28 18 00 AV3
-0.02 36 80 19 OD AV3
-0.42 36 81 17 00 AV3 0.02 36 93 20 00 AV2
-0.08 36 94 16 OD AV2
-0.05 36 96 21 00 AV2
-0.16 36 96 13 OD AV3 0.05 37 17 18 OD AV1
-0.08 37 23 13 00 AV2 0.08 37 34 15 00 AV3
-0.05 37 50 20 00 AV2 0
37 84 20 00 AV3 0.03 38 16 21 OD AV1
-0.03 38 16 20 00 AV2 0
38 22 22 OD AV1 0.28 38 22 17 OD AV2 0.1 38 22 19 00 AV3 0
38 25 15 00 AV1 0
38 25 20 00 AV2 0
38 25 16 00 AV3 0.09 38 62 23 00 AV2 0
38 62 18 OD AV3
-0.34 38 99 16 OD AV2 0.03 39 19 25 00 AV3 0.05 39 20 16 OD AV2 0.05 39 25 15 00 AV1 0.05 39 25 15 00 AV2 0
39 26 16 00 AV3
-0.2 39 35 31 00 AV2 0
39 35 32 OD AV3 0
39 38 20 OD AV3
-0.12 39 49 15 00 AV2 0
39 81 15 00 AV2 0.08 39 81 15 OD AV3
-0.08 39 83 24 00 AV2 0.22 39 83 16 00 AV4
-0.02 39 93 16 00 AV4 0
39 94 19 OD AV2
-0.1 40 21 29 00 AV2 0
Page 3 of 5
ATTACHMENT C3 ASME SECTION XI FORM NIS-BB 2C Steam Generator Page 4 of 5 EDDY CURRENT EXAMINATION RESULTS - REFUEL OUTAGE 12 Site: Byron Station, Unit 2 Steam Generator: 2RCOIBC Test Frequency: 20, 130, 300, 500 kHz Date:
10/5/2005
- 20, 100, 200, 300 kHz
% Tube Wall Row Column Penetration Origin Location Inch 40 21 13 OD AV3 0.06 40 83 30 OD AV2 0
40 83 22 00 AV3
-0.12 40 90 18 00 AV2
-0.05 40 90 19 OD AV3 0.05 40 90 16 00 AV4 0.05 40 93 19 OD AV1
-0.03 40 93 15 00 AV2
-0.02 40 93 26 00 AV3
-0.3 40 95 21 00 AV1 0
40 95 27 00 AV3
-0.23 41 26 15 OD AV2 0
41 26 18 00 AV3 0.31 41 27 15 00 AV2
-0.15 41 63 16 OD AV1 0.08 41 63 31 00 AV2 0
41 63 19 00 AV3 0
41 79 17 00 AV3 0
41 41 84 15 00 AVI
-0.16 84 20 OD AV3
-0.07 41 85 16 00 AV3 0.05 41 88 21 00 AV2 0.17 41 88 25 OD AV3
-0.1 41 89 31 00 AV1 0
41 89 22 OD AV2
-0.22 41 89 32 00 AV3 0
41 89 26 OD AV4
-0.19 41 92 15 00 AVI
-0.11 41 92 31 OD AV3 0
41 92 20 OD AV4
-0.17 42 23 16 00 AV3 0
42 25 20 OD AV3 0
42 29 15 OD AV2 0
42 29 24 00 AV3 0
42 85 18 00 AV3
-0.1 42 86 16 OD AV1 0
42 86 24 00 AV2 0
42 86 27 OD AV3
-0.25 42 88 20 00 AV2 0.25 42 88 20 OD AV3
-0.02 42 89 21 OD AV2 0.13 42 89 35 OD AV3 0
42 89 15 00 AV4
-0.11 42 90 29 OD AV3
-0.29 42 90 18 00 AV4
-0.05 Page 4 of 5
ATTACHMENT C~3 ASME SECTION XI FORM NIS-BB 2C Steam Generator Page 5 of 5 EDDY CURRENT EXAMINATION RESULTS - REFUEL OUTAGE 12 Site: Byron Station, Unit 2 Steam Generator: 2RCOIBC Test Frequency: 20, 130, 300, 500 kHz Date:
10/5/2005
- 20, 100, 200, 300 kHz
%_Tube_Wall Row Column Penetration Origin Location Inch 42 93 28 00 AV1 0
42 93 19 00 AV2 0
42 93 33 OD AV3
-0.27 42 93 18 00 AV4 0.03 42 94 13 00 AV2 0
42 94 26 00 AV3 0.1 42 94 18 00 AV4
-0.08 43 30 16 OD AV3 0
43 34 21 00 AV3
-0.12 43 36 23 OD AV3 0
43 36 19 00 AV4
-0.15 43 93 18 OD AV1 0
43 93 24 00 AV2
-0.08 43 93 20 OD AV3
-0.18 48 35 8
00 02C
-0.05
- 49 48 39 OD 07C
-0.47 49 62 49 00 07C
-0.08 49 63 49 00 07C
-0.22 49 70 31 00 07C 0.03
- 49 73 23 00 07C
-0.39 49 83 15 00 AV4 0
Page 5 of 5
Attachment C.4 SG D ASME Form NIS-BB Page 28 of 31
ATTACHMENT C.4 ASME SECTION XI FORM NIS-BB 2D Steam Generator Page 1 of 4 EDDY CURRENT EXAMINATION RESULTS - REFUEL OUTAGE 12 Site: Byron Station, Unit 2 Steam Generator: 2RCOI BD Test Frequency: 20, 130, 300, 500 kHz Date:
10/5/2005
- 20, 100, 200, 300 kHz
%_Tube Wall Row Column Penetration Origin Location Inch
- 1 55 26 00 06C 0.26 19 82 17 00 AV4 0
20 5
16 00 AV4 0.22 21 57 17 00 AVI 0.15 21 57 16 00 AV4 0
- 24 65 11 OD 02C 1
25 30 15 00 AV3
-0.41 25 50 25 00 AV2 0.09 25 108 24 OD AVI 0
25 108 16 00 AV2 0
25 108 22 OD AV4 0
26 70 25 00 AV2
-0.31 26 70 21 00 AV3
-0.21 26 107 20 00 AV3
-0.02 26 107 17 00 AV4 0
28 28 25 OD AV4
-0.5 28 36 33 00 AV2 0
28 78 18 OD AV3 0
28 102 19 OD AV3
-0.03 29 63 16 00 AV2 0.18 30 103 25 00 AV2
-0.05 30 104 16 00 AV2 0
30 104 17 00 AV4 0.03 31 13 18 OD AV1 0.05 31 13 23 00 AV3 0.08 31 14 17 OD AV4 0
31 44 34 00 AV2
-0.05 31 44 23 00 AV3
-0.05 31 50 19 00 AV2
-0.05 31 50 32 OD AV3
-0.03 31 50 17 OD AV4 0
31 84 23 00 AV2 0.08 31 84 18 00 AV3 0.05 31 84 15 OD AV4
-0.17 31 103 22 00 AV2 0
31 103 23 00 AV3
-0.03 31 103 18 OD AV4
-0.06 31 104 16 OD AV1
-0.03 31 104 22 00 AV3 0
32 79 18 OD AV3
-0.08 33 70 24 00 AV3 0.13 34 87 18 OD AV2 0.1 34 87 23 OD AV3
-0.05 34 95 19 00 AV3 0
34 97 15 OD AV1 0.03 Page 1 of 4
ATTACHMENT CA ASME SECTION XI FORM NIS-BB 2D Steam Generator Page 2 of 4 EDDY CURRENT EXAMINATION RESULTS - REFUEL OUTAGE 12 Site: Byron Station, Unit 2 Steam Generator: 2RCOI BD Test Frequency: 20, 130, 300, 500 kHz Date:
10/5/2005
- 20, 100, 200, 300 kHz
%_Tube Wall Row Column Penetration Origin Location Inch 34 97 28 00 AV2 0
34 97 15 00 AV3 0
34 98 17 00 AV2 0.03 34 98 22 OD AV3 0.03 34 99 15 00 AV1 0.03 34 99 15 00 AV2 0.13 34 99 20 00 AV3
-0.03 34 99 38 00 AV4 0
34 100 19 00 AV3 0
35 14 20 00 AV4 0
35 17 28 00 AV2 0.03 35 17 17 00 AV3 0.08 35 20 25 00 AV2 0
35 91 15 00 AV2
-0.11 35 92 15 00 AV2
-0.03 35 95 32 00 AV2
-0.03 36 17 21 00 AV2 0.16 36 19 17 00 AV3 0.13 36 21 22 00 AV2 0.26 36 37 31 00 AV2 0
36 37 27 OD AV3 0
36 72 17 00 AV2 0.18 36 72 17 00 AV3
-0.03 36 82 31 OD AV2 0.03 36 82 22 00 AV3
-0.03 36 82 21 OD AV4
-0.03 36 83 17 00 AV1
-0.07 36 83 24 00 AV2 0
36 83 16 00 AV3
-0.05 36 84 17 00 AV2 0.08 36 94 17 OD AV3
-0.03 36 95 17 00 AV3 0.06 36 100 18 OD AV4
-0.15 37 20 17 00 AV3 0.06 37 33 16 OD AV1 0.05 37 33 29 OD AV2 0
37 33 28 00 AV3
-0.03 37 42 34 00 AV2
-0.03 37 42 15 OD AV3 0
37 87 18 OD AV3 0.05 38 25 22 00 AV3 0.08 39 19 15 00 AV3 0.03 39 27 15 OD AV2 0.13 39 27 19 OD AV3 0.26 39 72 21 00 AV2 0.1 Page 2 of 4
ATTACHMENT CA ASME SECTION XI FORM NIS-BB 2D Steam Generator Page 3 of 4 EDDY CURRENT EXAMINATION RESULTS - REFUEL OUTAGE 12 Site: Byron Station, Unit 2 Steam Generator: 2RCOIBD Test Frequency: 20, 130, 300, 500 kHz Date:
10/5/2005
- 20, 100, 200, 300 kHz
%_Tube_Wall Row Column Penetration Origin Location Inch 39 72 27 00 AV3 0
39 80 17 00 AV2 0.1 39 80 28 00 AV3
-0.05 39 90 26 00 AV4 0
40 25 18 00 AV3 0.08 40 26 17 00 AV3 0.08 40 29 30 00 AV2 0
40 29 23 00 AV3 0.16 40 33 21 00 AV2 0.15 40 33 26 OD AV3
-0.03 40 33 16 00 AV4 0
40 36 16 00 AV2 0
40 36 17 00 AV3
-0.11 40 73 19 00 AV2
-0.03 40 76 16 00 AV1 0
40 76 28 00 AV2 0
40 90 21 00 AV3 0
40 92 20 00 AV3
-0.03 41 20 21 00 AVI 0.05 41 20 27 OD AV2 0
41 32 15 00 AV2 0.16 41 32 16 OD AV3 0.1 41 33 24 00 AV2 0
41 33 18 00 AV3
-0.17 41 60 17 00 AVI 0.4 41 60 17 00 AV2 0.21 41 80 23 OD AV1 0
41 86 20 00 AV2
-0.15 41 86 35 00 AV3
-0.08 41 86 17 OD AV4
-0.24 41 92 18 00 AV3
-0.03 42 29 15 00 AV2 0.31 42 36 34 00 AV2
-0.05 42 36 23 00 AV3
-0.03 43 22 20 00 AV1
-0.13 43 22 20 OD AV2 0.24 43 85 15 00 AV3
-0.03 46 89 16 OD AV4 0
47 56 17 OD AV3 0.03 47 56 27 00 AV4 0.03 48 59 25 00 AV3
-0.06 48 59 20 00 AV4
-0.08
- 48 63 19 00 07C 0.36 48 71 13 OD AV1
-0.03
- 49 52 39 OD 07C 0.43 Page 3of4
ATTACHMENT C.4 ASME SECTION XI FORM NIS-BB 2D Steam Generator Page 4 of 4 EDDY CURRENT EXAMINATION RESULTS - REFUEL OUTAGE 12 Site: Byron Station, Unit 2 Steam Generator: 2RCOIBD Test Frequency: 20, 130, 300, 500 kHz Date:
10/5/2005
- 20, 100, 200, 300 kHz
%_Tube_Wall Row Column Penetration Origin Location Inch 49 67 31 00 07C 49 69 33 00 07C
-0.08
-0.05 Paqe4 of 4
ATTACHMENT D ASME FORM NIS-1 OWNERS REPORT FOR INSERVICE INSPECTION Page 29 of 31
ATTACHMENT D.1 FORM NIS-1 OWNERS REPORT FOR INSERVICE INSPECTIONS As Required by the Provisions of the ASME Code Rules
- 1. Owner:
Exelon Generation Company, LLC, 200 Exelon Way, Kennett Square, PA, 19348 (Name and Address of Owner)
- 2. Plant:
Byron Station, 4450 North German Church Road, Byron, Illinois, 61010 (Name and Address of Plant)
- 3. Plant Unit:
Two (2)
- 4. Owner Certificate of Authorization (ifrequired):
N/A
- 5. Commercial Service Date:
08/21/87
- 6. National Board Number for Unit:
N-200
- 7. Components Inspected: Steam Generator Eddy Current Inspection Cycle 12 Componentor Appurtenance Manufacturer or Installer Manufacturer or InstallerSerial No.
State or Province No.
National Board No.
2RCO I BA Westinghouse 2095 U-20 1435 15 2RCOIBB Westinghouse 2096 U-201436 16 2RCOIBC Westinghouse 2097 U-201437 17 2RCOIBD Westinghouse 2098 U-201438 18 Page 30 of 31
FORM NIS-1 (Back)
- 8. Examination Dates 09/29/05 to 10/05/05 9.
Inspection Interval from 08/21/98 (extended) to 08/21/07 10.
Abstract of Examinations. Include a list of examinations and a statement concerning status of work required for current interval.
Refer to the Attached Report II.
Abstract ofConditions Noted Refer to the Attached Report
- 12. Abstract of Corrective Measures Recommendedand Taken Refer to the Attached Report We certif~that the statements made in this report are correct and the examinations and corrective measures taken conform tothe rules of the ASME Code,Section XI.
Certificate of Authorization No. (ifapplicable)
Not Applicable Date Signed For Exelon GeneratingCompany, LLC Owner 1
~Not AppIic~kIe By CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of oiler nd Pressure Vessel In~pectorsand the State or Province of f//,~j..~ and employed by
~~$j$-
~P of
~
6gf//#Vt have inspected the components described in this Owners Report during the period Q
1 to /~ 5 ~f, and state that to the best of my knowledge and belief, the Owner has performed examinations and aken corrective mea~res described in this Owners Report in accordance with the requirements ofthe ASME Code, Section Xl.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthennore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Commissions
/~I~//SY
~~pectors Signature National Board, State, Province, and Endorsements Date 5.
Page 31 of 31