SEE NOTE 2 (THIS DWG)
A B
C A
B C
TO RFW-FSPV-2B M504-2 (D/9)
AND COND-PS-28B M504-2 (G/7)
TO RFW-FSPV-2A M504-2 (D/12)
AND COND-PS-28A M504-2 (G/10)
FSAR FIG 12 PAA REV PER 55-3026-0A-201 (G\\3)
D JACOBSEN 4-28-86 SR PAYNE JR MILLER JE PARKER 3-11-87 3-11-87 3-11-87 3-11-87 JE PARKER APPROVED ENGINEER DESIGN SUPV CHECKED DRAWN 14" AR(1)-1 14" AR(1)-1 BD T MS-T-9A BY PASS 1 1/2" 1 1/2" VALVE FO MS-T-9B SOLENOID VALVE T
6" 2" MD(1)-2 1"
1" 2"
34 DETAIL "C" TRAP STATION #34 MS-4 MD-2 3/4" T
6" MS(3)-4 1/2" 1/2" 1" MD(24)-1 DETAIL "D" TRAP STATION 33A & 33B SS-1 MD-1 3/4" T
3/4" LINE NO FOR DETAILS SEE TO OFFGAS PRE HTR M506 (F/12)
M506 (F/12)
M506 (E/12)
M506 (A/6)
M506 (A/6)
M506 (E/5)
M506 (E/5)
M506 (H/13)
M506 (F/15)
M506 (F/10)
M506 (G/10)
M506 (A/6)
M506 (E/5)
M506 (E/5)
M506 (E/5)
M506 (F/4)
M502-1 (D/13)
M502-1 (D/13)
M502-1 (D/13)
M502-1 (D/14)
M506 (E/5)
M506 (E/5)
M506 (H/12)
M506 (F/11)
M506 (E/11)
M506 (E/11)
M506 (E/4)
M506 (E/7)
M506 (E/7)
M506 (F/7)
M506 (F/10)
M506 (F/10)
M506 (F/9)
M506 (F/9)
LOCATION DISCHARGE ON DWG D
D C
B B
A A
A A
A A
B A
A A
A A
A A
A A
A A
A A
A A
A A
A A
A A
A DETAIL SS-LS-33A SS-V-76 1 1/2"SS(9)-1 SS-V-80 SS-V-81 33A M502-3 (B/1)
SS-T-7A SS-V-77 SS-V-78 SS-V-79 SS-V-74 SS-V-75 SS-LS-33B SS-V-68 2 1/2"SS(8)-1 SS-V-72 SS-V-73 33B M502-3 (B/1)
SS-T-7B SS-V-69 SS-V-70 SS-V-71 SS-V-66 SS-V-67 DETAIL "B" SEALING STEAM TRAP STATION #22,31 & 32 FLOW 1"
1/2" 1/2" (VENT) 3/4" SS(3)-1 DISCHARGE TO MD-TK-1 SEE M506 (A/6) FOR DETAIL 2"
4" SS-ST-1A (TS #31)
SS-ST-1B (TS #32)
BLOWOFF PLUGGED SS(3)-1 MD(6)-1 T
1 1/2" SS(3)-1 3/4" X 1" 3/4" X 1" 1"
2" MS(50)-4-12 2" MS(50)-4-13 2" MS(50)-4-14 2" MS(50)-4-15 6" MS(1)-4-27 6" MS(1)-4-28 6" MS(1)-4-29 6" MS(1)-4-30 a
3/4" MS(55)-4-10 2" MS(55)-4-11 3/4" MS(55)-4-12 3/4" MS(55)-4-13 TRAP STATION NO MS-T-1A MS-T-1B MS-T-1C MS-T-1D b
1" MS(50)-4-16 1" MS(50)-4-17 1" MS(50)-4-18 1" MS(50)-4-19 f
1" MS(50)-4-12 1" MS(50)-4-13 1" MS(50)-4-14 1" MS(50)-4-15 e
1" MS(60)-4-23 1" MS(60)-4-24 1" MS(60)-4-25 1" MS(60)-4-26 d
DETAIL "A" TRAP STATION COMPONENT NUMBERS UNIQUE LINE NUMBER (SEE DETAIL A)
PLANT BAROMETERIC PRESSURE TABLE I 1" MS(60)-4-19 1" MS(60)-4-20 1" MS(60)-4-21 1" MS(60)-4-22 c
DISCHARGE TO CONDENSER (SEE M506 FOR DETAIL EXCEPT FOR TS #14 THRU TS #17, SEE M502-1 (D/12-14)
SEE NOTE BELOW (*)
MD-2 1"
e BYPASS VALVE SOLENOID VALVE 3/4" EXCEPT WHERE OTHERWISE NOTED ON M506 2" MD(1)-2 T
e 2"
1" 1"
f 1/2" b
1/2" LINE NO a
6" FROM M502-1 (C/1) 1" MS(3)-4 (TS #9A ONLY) d c
MD-V-093(D)
MD-V-094(D)
MD-V-099(D)
MD-V-100(D)
MD-V-631(D)
MD-V-097(D) 34 MS-T-9B MS-V-242B MS-V-243B MS-LS-34 MS-SPV-34 MS-V-244 6" MS(3)-4 MS-V-251 MS-V-252 M502-1 (C/5)
MS-T-9A MS-V-242A MS-V-243A MS-V-245 MS-V-254 MS-V-253 SS-LS-24B SS-V-51B 4" SS(3)-1 SS-V-715B SS-V-716B 32 M502-3 (K/15)
SS-T-5B SS-V-52B SS-V-53B SS-V-61A SS-V-61B SS-LS-24A SS-V-51A 4" SS(3)-1 SS-V-715A SS-V-716A 31 M502-3 (G/15)
SS-T-5A SS-V-52A SS-V-53A SS-V-60A SS-V-60B 30 DELETED 29 DELETED BS-LS-68 BS-SPV-68 BS-V-68 14" BS(5)-2 BS-V-757 BS-V-758 28 M502-2 (E/12)
BS-T-10 BS-V-69 BS-V-70 BS-V-71 BS-V-82A BS-V-82B BS-LS-64 BS-SPV-64 BS-V-64 14" BS(5)-2 BS-V-755 BS-V-756 27 M502-2 (B/12)
BS-T-9 BS-V-65 BS-V-66 BS-V-67 BS-V-81A BS-V-81B SS-LS-1 SS-SPV-30 SS-V-30 8" SS(10)-1 SS-V-705 SS-V-706 26 M502-3 (C/3)
SS-T-4 SS-V-28 SS-V-29 SS-V-36 SS-V-59A SS-V-59B BS-LS-56 BS-SPV-56 BS-V-56 16" BS(1)-2 BS-V-723 BS-V-724 25 M505-2 (B/8)
BS-T-8 BS-V-57 BS-V-58 BS-V-59 MD-V-088(D)
BS-V-80A BS-V-80B MS-LS-147 MS-SPV-147 MS-V-147 18" MS(2)-4 MS-V-742 MS-V-743 24 M505-2 (E/11)
MS-T-7 MS-V-148 MS-V-149 MS-V-150 MD-V-638(D)
MS-V-185A MS-V-185B SS-LS-20 SS-SPV-20 SS-V-20 6" SS(1)-2 SS-V-711 SS-V-712 23 M502-3 (B/9)
SS-T-3 SS-V-21 SS-V-22 SS-V-35 SS-V-58A SS-V-58B SS-LS-16 SS-SPV-16 SS-V-16 6" SS(3)-1 SS-V-707 SS-V-708 22 M502-3 (K/14)
SS-T-2 SS-V-17 SS-V-18 SS-V-19 SS-V-57A SS-V-57B SS-LS-12B SS-SPV-12B SS-V-12B 3" SS(2)-2 SS-V-710A SS-V-710B 21 M502-3 (G/12)
SS-T-1B SS-V-13B SS-V-14B SS-V-15B SS-V-56A SS-V-56B SS-LS-12A SS-SPV-12A SS-V-12A 3" SS(2)-2 SS-V-709A SS-V-709B 20 M502-3 (D/12)
SS-T-1A SS-V-13A SS-V-14A SS-V-15A SS-V-55A SS-V-55B BS-LS-52B BS-SPV-52B BS-V-52B 12" BS(1)-2 BS-V-721B BS-V-722B 19 M505-2 (K/14)
BS-T-7B BS-V-53B BS-V-54B BS-V-55B BS-V-79A BS-V-79B BS-LS-52A BS-SPV-52A BS-V-52A 12" BS(1)-2 BS-V-721A BS-V-722A 18 M505-2 (K/12)
BS-T-7A BS-V-53A BS-V-54A BS-V-55A BS-V-78A BS-V-78B BS-LS-39B BS-SPV-39B BS-V-39B 6" BS(2)-2 BS-V-719B BS-V-720B 17 M502-1 (B/12)
BS-T-6B BS-V-40B BS-V-41B BS-V-42B MD-V-629(D)
BS-V-77A BS-V-77B BS-LS-39A BS-SPV-39A BS-V-39A 6" BS(2)-2 BS-V-719A BS-V-720A 16 M502-1 (D/12)
BS-T-6A BS-V-40A BS-V-41A BS-V-42A MD-V-625(D)
BS-V-76A BS-V-76B MS-LS-137B MS-SPV-137B MS-V-137B 6" MS(6)-4 MS-V-740B MS-V-741B 15 M502-1 (A/11)
MS-T-6B MS-V-138B MS-V-139B MS-V-140B MD-V-634(D)
MS-V-184A MS-V-184B MS-LS-137A MS-SPV-137A MS-V-137A 6" MS(6)-4 MS-V-740A MS-V-741A 14 M502-1 (B/11)
MS-T-6A MS-V-138A MS-V-139A MS-V-140A MD-V-632(D)
MS-V-183A MS-V-183B MS-LS-24L MS-SPV-133B MS-V-133B 4" MS(7)-4 MS-V-738B MS-V-739B 13 M502-2 (G/11)
MS-T-5 MS-V-134B MS-V-135B MS-V-136B MS-V-182A MS-V-182B BS-LS-29C BS-SPV-35A BS-V-35A 18" BS(5)-2 BS-V-717A BS-V-718A 12 M502-2 (C/11)
BS-T-5 BS-V-36A BS-V-37A BS-V-38A BS-V-75A MS-V-75B BS-LS-29B BS-SPV-31 BS-V-31 16" BS(1)-2 BS-V-715 BS-V-716 11 M505-2 (B/8)
BS-T-4 BS-V-32 BS-V-33 BS-V-34 BS-V-74A MS-V-74B BS-LS-29A BS-SPV-27 BS-V-27 16" BS(1)-2 BS-V-713 BS-V-714 10 M505-2 (B/8)
BS-T-3 BS-V-28 BS-V-29 BS-V-30 MD-V-641(D)
BS-V-73A MS-V-73B MS-LS-24M MS-SPV-189 MS-V-189 24" MS(3)-4 MS-V-759 MS-V-760 9B M502-1 (B/7)
MS-T-4B MS-V-190 MS-V-191 MS-V-192 MS-V-181C MS-V-181D MS-LS-24J MS-SPV-186 MS-V-186 24" MS(3)-4 MS-V-736 MS-V-737 9A M502-1 (B/2)
MS-T-4A MS-V-187 MS-V-188 MS-V-132 MS-V-181A MS-V-181B MS-LS-24H MS-SPV-125B MS-V-125B 12" MS(2)-4 MS-V-734B MS-V-735B 8
M505-2 (K/10)
MS-T-3B MS-V-126B MS-V-127B MS-V-128B MS-V-180A MS-V-180B MS-LS-24G MS-SPV-125A MS-V-125A 12" MS(2)-4 MS-V-734A MS-V-735A 7
M505-2 (K/6)
MS-T-3A MS-V-126A MS-V-127A MS-V-128A MS-V-179A MS-V-179B MS-LS-24 MS-SPV-121 MS-V-121 12" MS(2)-4 MS-V-732 MS-V-733 6
M505-2 (E/10)
MS-T-2 MS-V-122 MS-V-123 MS-V-124 MS-V-178A MS-V-178B BS-LS-30 BS-SPV-48 BS-V-48 12" BS(1)-2 BS-V-711 BS-V-712 5
M505-2 (B/12)
BS-T-1 BS-V-49 BS-V-50 BS-V-51 BS-V-72A BS-V-72B MS-LS-24D MS-SPV-120D MS-V-120D 30" MS(1)-4 MS-V-730D MS-V-731D 4
M502-1 (D/9)
MS-T-1D MS-V-117D MS-V-118D MD-V-643(D)
MS-V-177A MS-V-177B MS-LS-24C MS-SPV-120C MS-V-120C 30" MS(1)-4 MS-V-730C MS-V-731C 3
M502-1 (E/9)
MS-T-1C MS-V-117C MS-V-118C MD-V-642(D)
MS-V-176A MS-V-176B MS-LS-24B MS-SPV-120B MS-V-120B 30" MS(1)-4 MS-V-730B MS-V-731B 2
M502-1 (B/8)
MS-T-1B MS-V-117B MS-V-118B MD-V-627(D)
MS-V-175A MS-V-175B MS-LS-24A MS-SPV-120A MS-V-120A 30" MS(1)-4 MS-V-730A MS-V-731A 1
M502-1 (C/7)
MS-T-1A "J"
VALVE NO "H"
VALVE NO "G"
VALVE NO "F"
VALVE NO "D"
VALVE NO "C"
VALVE NO "B"
VALVE NO ROOT VALVE NO "Z" MS-V-117A MS-V-118A MD-V-621(D)
MS-V-174A MS-V-174B "A"
VALVE NO SOLENOID VALVE BY PASS VALVE LINE NO
- ALL PIPING UPSTREAM OF THE BY PASS VALVE & VALVE "B" HAVE THE SAME DESIGNATION & PRESSURE RATING OF THE SOURCE LINE.
FOR LINE SIZES SMALLER THAN 6" DRIP LEG SHALL HAVE SAME DIAMETER AS MAIN LINE ROOT VALVE N0 "Y" NO NO TRAP NO LEVEL SWITCH NO TRAP STA TRAP LOCATION ON DWG NO 3" MS(7)-4 COND-EJC-1A2 2"
MS-ASW-11A MS-SPV-11A 2"
3" FC FC MS-SPV-12A 2ND STAGE COND-EJC-2A DWG M511 (D/12) 8" HV(20)-1 EJECTOR CONDENSER COND-HX-8A COND-EJC-1A1 2"
M511 (D/9)
M511 (D/9) 14" AR(1)-1 14" AR(1)-1 CLOSES VALVES ARV-2A, -2B ON LOW STEAM FLOW, SEE DWG M511 (D/10)
STEAM JET AIR EJECTOR MS-SPV-17A 2" MS(7)-4 2" MS(7)-4 2 1/2" X 2" (TYP) 2" 2"
MS-ST-6A MS-SPV-16A 2 1/2" X 2" (TYP) 2" 2"
MS-ST-4A M511 (D/11)
M511 (D/11)
COND-EJC-1B2 2"
MS-ASW-11B SEE NOTE 3 (THIS DWG)
MS-SPV-11B 2"
3" FC FC FO MS-SPV-12B 2ND STAGE COND-EJC-2B FOR DETAILS, SEE DWG M511 (D/10)
COND-HX-9C COND-HX-9B COND-HX-9A 8" HV(20)-1 72" ES(1)-1 72" ES(1)-1 8" HV(20)-1 EJECTOR CONDENSER COND-HX-8B COND-EJC-1B1 2"
CLOSES VALVES ARV-2C, -2D ON LOW STEAM FLOW, SEE DWG M511 (D/12)
MS-SPV-17B STEAM JET AIR EJECTOR 2 1/2" X 2" (TYP) 2" 2"
MS-ST-5B CONT'D ON DWG M535-1 (G/9 & H/14) 1 1/2" MS(8)-4 (ZONE E/2) 1 1/2" MS(8)-4 MOISTURE SEPARATOR MS-HX-2 8" MS(5)-4 FROM MAIN STEAM CONT'D M502 SH 1 (A/9) 1 1/4" MS-T-8 1 1/2" 2"
MD(16)-2 MS(5)-4 2"
3/4" 3/4" MS-SPV-234 2"
3/4" 1 1/4" T
2" 8" MS(5)-4 TRAP STA #13 4" X 3" 3"
MS-ST-6B FO FO MS-SPV-16B 2 1/2" X 2" (TYP) 2" 2"
MS-ST-4B 3"
1 1/2" MS(8)-4 8" AS(4)-2 FROM AUX BOILER DWG M513 (H/9)
TRAP STA #12 (ZONE E/2) 14" TRAP STA #27 (ZONE E/2) 2" MD(6)-1 CONT'D DWG M506 (D/9) 16" ES(20)-1 2" ES(20)-1 2" MD(20)-1 CONT'D DWG M506 (B/11)
TURBINE TRIP BS BS BS 14" BS(5)-2 M506 (B/9)
TO DRAIN VALVE LOGIC 72" ES(1)-1 14" TRAP STA #28 (ZONE E/2) 2" MD(6)-1 CONT'D DWG M506 (C/4) 16" ES(20)-1 2" ES(20)-1 2" MD(20)-1 ES-1 MD-1 CONT'D DWG M506 (B/6)
TURBINE TRIP BS BS BS 14" BS(5)-2 TO DRAIN VALVE LOGIC M506 (B/4) 72" ES(1)-1 ES-V-1B ES-RD-1B 14" ES(1)-1 2"
ES MD 2" ES(1)-1 2" MD(5)-1 CONT'D DWG M506 (D/5)
ES-EJ-1B M504 (D/11)
ES TO RFW TURBINE TRIP LOGIC LP STOP VALVE VALVE HP STOP 8" MS(5)-4 FROM MS-HX-1B DWG M502 SH 1 (H/11) 18" BS(5)-2 12" 4"
6" MS(5)-4 RFW-DT-1B REACTOR FEED WATER PUMP RFW-P-1B ES-V-1A ES-RD-1A 14" ES(1)-1 2"
ES MD 2" ES(1)-1 2" MD(5)-1 CONT'D DWG M506 (D/11)
ES-EJ-1A ES TO RFW TURBINE TRIP LOGIC LP STOP VALVE VALVE HP STOP 12" 4"
6" MS(5)-4 M504 (D/12)
RFW-DT-1A REACTOR FEED WATER PUMP RFW-P-1A NOTE:
FOR NOTES AND LEGEND, SEE M502 SH 1.
1.
2.
3.
a) WHEN MS-SPV-12A IS ENERGIZED, MS-ASW-11A PORT A TO B IS CONNECTED.
b) WHEN MS-SPV-12A IS DE-ENERGIZED, MS-ASW-11A PORT A TO C IS CONNECTED.
a) WHEN MS-SPV-12B IS ENERGIZED, MS-ASW-11B PORT A TO B IS CONNECTED.
b) WHEN MS-SPV-12B IS DE-ENERGIZED, MS-ASW-11B PORT A TO C IS CONNECTED.
REV DATE DWN CHK APVD DESCRIPTION FLOW DIAGRAM MAIN & EXHAUST STEAM SYSTEM TURBINE GENERATOR BUILDING A
B C
D E
F G
H J
K A
B C
D E
F G
H J
K 4
5 7
6 8
9 10 11 12 13 14 15 2
3 1
4 5
7 6
8 9
10 11 12 13 14 15 2
3 REV DATE DWN CHK APVD DESCRIPTION N/A 20 2
3 M502 TITLE DATE SIGNED SCALE REV.
SHEET OF DRAWING #
HO HO TS 1A1 ES TS 1A2 ES MS-V-727A MS-V-726A PX 21A C
A0281 C
A0030 PI 21A PI 21AG PT 21A TE 21A R/I 21A TI 21A TE 5A RFT TS 1A3 ES RMS BD A O
C MO C
A0032 BS-V-60A MS-V-172A AL BS-V-709A C
A0038 PI 17A MS-V-729A C
A0040 PI 1A PS 1A3 ES PS 1A2 ES PS 1A1 ES PI 1AG ES PT 1A ES ES-V-701A MD-V-96A ES-V-2A O
C RMS BD A MO HO HO TS 1B1 ES TS 1B2 ES MS-V-726B PX 21B C
A0031 PI 21B PI 21BG PT 21B TE 21B R/I 21B TI 21B M504 (D/12)
TO RFW-TR-1 TE 5B RFT TS 1B3 ES RMS BD A O
C MO C
A0033 O
C RMS BD A MO MS-V-225(V)
MS-V-105B(TH)
C A0287 BS-V-60B MS-V-172B AL BS-V-709B C
A0039 PI 17B MS-V-729B C
A0041 PI 1B PS 1B3 ES PS 1B2 ES PS 1B1 ES PI 1BG ES PT 1B ES ES-V-701B MD-V-96B ES-V-2B O
C RMS BD A MO C
A0035 PI 22B S
22B PI 22BG TX 17B BS BS-V-093(V)
C A0037 TE 17B BS R/I 17B TI 17B PI 17BG BS PT 17B BS ES-V-4B C
AH AH C
MD-V-95B BS-V-17B(TH)
BS-V-18B O
C RMS BD A MO BS-V-708B PX 17B BS PT 22B C
A0034 PI 22A S
22A PI 22AG TX 17A BS BS-V-092(V)
C A0036 TE 17A BS R/I 17A TI 17A PI 17AG BS PT 17A BS ES-V-4A C
AH AH C
MD-V-95A BS-V-17A(TH)
BS-V-18A O
C RMS BD A MO BS-V-708A PX 17A BS PT 22A O
C RMS BD A MO MS-V-224(V)
MS-V-105A (TH)
RMS BD B MO MS-V-712B DPIS 10B MS-V-754B MS-V-169B MS-V-170B A
MS-PCV-16B PT 16B PI 16BG PS 16B MS-V-713B PC 16B A
PC 17B LS 25 AH O
C MS-V-232 MS-V-231(D)
RMS BD T MS-V-236 MS-V-763 MS-V-235 MS-V-762 MS-V-233 A
O C
MS-V-234 MS-V-241(V)
MS-V-237 MS-V-727B O
C RMS BD B MO MS-V-115B O
C RMS BD B MO MS-V-115A MS-V-110B O
C MS-V-746D DPIS 10D MS-V-747D MS-V-161B A
RMS BD B AH MS-V-162B A
MS-PCV-17B O
C MS-V-756B PS 25B PS 17B C
MS-V-714B MS-V-745B FI 25B C
A0025 AL FS 25B SQRT 25B FT 25B MS-V-167B 39 97 HV-RV-23B MS-V-51B O
C RMS BD B A
MS-V-755B C
PC 11B PI 11BG O
C A
O C
C RMS BD B MO MS-V-754A DPIS 10A MS-V-712A MS-V-169A MS-V-170A A
MS-PCV-16A PT 16A PI 16AG PS 16A MS-V-713A PC 16A A
PC 17A MS-V-110A O
C MS-V-746C DPIS 10C MS-V-747C MS-V-161A A
RMS BD B AH MS-V-162A A
MS-PCV-17A O
C MS-V-756A PS 25A PS 17A C
MS-V-714A MS-V-745A FI 25A C
A0024 AL FS 25A SQRT 25A FT 25A MS-V-168A MS-V-601(V)
HV-RV-23A MS-V-51A O
C RMS BD B A
MS-V-755A C
PC 11A PI 11AG O
C A
O C
"Z" RMS BD T AH O
C LS "G"
"H" "B"
"A" "D"
"C" "J"
"F" AO O
C C
A0478 PT 1
PL "Y"
"Z" AH O
C "B"
"A" LS SS-V-62A (TS #31)
SS-V-62B (TS #32)
"G" "H"
93 39 "Y"
"Z" AH LS "G"
"H" "B"
"C" "Y"
"Z" AH LS "G"
"H" "B"
AO "C"
O C
"A" "B"
"A" RMS O
C A
A FO MANUAL BYPASS VALVE MANUAL BYPASS VALVE "A"
M504 (D/12)
TO RFW-TR-1 O
C MS-PCV-13B MS-V-12B MS-PCV-11B MS-PCV-13A MS-V-12A MS-PCV-11A 6-17-94 HL JHD 3/4" MS-V-799 3/4" PX 3/4" 13 REV PER 94-0284-0A-A06 (H-K/10,13-14)
MJH SERVER84\\00\\DWG PX PX 3-2-95 KL RC REV PER 93-0048-0A-004 (D/1,2; F,J/3) 14 MJH 7-13-95 HL RC 172A 60A MS BS SEE M985-1 (D/6)
SEE M985-1 (D/5)
SEE M985-2 (D/6)
MS 172B SEE M985-2 (D/5)
BS 60B 15 12-30-97 REVISED PER 55-3034-0A-303 (B-C/13-14), 55-3034-0A-304 (E-F/13-14). TRANSLATED DRAWING.
KL HL DLE COLUMBIA GENERATING STATION 16 11-02-00 REV PER 96-0153-0A-345(G/12), 96-0153-0A-346(D-E/12-13), & 96-0153-0A-347(A/12).
LWC KL SRP PX 30 BS TX 30 BS BS-V-3 3/4" AS-2 BS-2 FLANGED SPOOL PIECE FOR RFW TURBINE OVERSPEED TESTING.
REMOVE & BLANK-OFF DURING NORMAL OPERATION.
AS-V-10 BS-V-710 FLANGED ELBOW FOR RFW TURBINE OVERSPEED TESTING.
INSTALL BLANK FOR OS TESTING.
17 4-12-01 REV PER 00807-0004 (B-D/11-13).
HL KL SRP AS-V-604 (V)
AS-V-89 AS-V-90 3/4" FOR MS-T-1A THRU MS-T-1D UNIQUE LINE NUMBERS, SEE TABLE 1 (J/1-4)
FOR ACTUAL PIPING LINE SIZES SEE APPLICABLE ISOMETRICS.
KB HL SRP 18 10-11-01 REV PER 01202-004 (E/1-3) 19 2-8-02 REV PER 01487-008 (C/13, F/13), 97-0137-0A-332 (B/1-7)
KB HL SRP MS-V-171A MS-V-171B MS-V-173A MS-V-173B 20 08/28/03 REV PER 02623-003 (K/7 & 13, J/9-11).
LS HL DRJ