November 16, 2005 LICENSEE:
AmerGen Energy Company, LLC FACILITY:
Oyster Creek Nuclear Generating Station
SUBJECT:
SUMMARY
OF MEETING HELD ON OCTOBER 20, 2005, BETWEEN THE U.S. NUCLEAR REGULATORY COMMISSION (NRC) STAFF AND AMERGEN ENERGY COMPANY, LLC REPRESENTATIVES TO DISCUSS THE RESULTS OF THE SCOPING AND SCREENING METHODOLOGY AUDIT FOR THE OYSTER CREEK NUCLEAR GENERATING STATION LICENSE RENEWAL APPLICATION On October 20, 2005, the NRC staff met with members of AmerGen Energy Company, LLC (the applicant) in a public meeting to discuss the results of the scoping and screening methodology audit supporting the review of the license renewal application (LRA) for the Oyster Creek Nuclear Generating Station. The application was submitted by letter dated July 22, 2005.
The list of attendees is provided in Enclosure 1.
The NRC staff provided an overview of the areas reviewed during the audit, as well as the results of the review. The staff determined the applicant used a sound, well organized scoping and screening methodology, and that the scoping and screening process was implemented consistent with the applicants procedures. There were four areas in which additional information will be requested: (1) the technical basis for crediting 11 grouted wall penetration as an equivalent anchor for small bore piping; (2) verify that underground piping was not credited as an anchor that is equivalent to a seismic anchor; (3) describe the Quality Assurance program for the combustion turbines; and (4) verify scoping of support systems using plant and industry experience. The staff also answered numerous questions from the public regarding the methods used during the Oyster Creek audit and the license renewal process in general.
/RA/
Donnie J. Ashley, Project Manager License Renewal Branch A Division of License Renewal Office of Nuclear Reactor Regulation Docket No.: 50-219
Enclosures:
As stated cc w/encls: See next page
November 16, 2005 LICENSEE:
AmerGen Energy Company, LLC FACILITY:
Oyster Creek Nuclear Generating Station
SUBJECT:
SUMMARY
OF MEETING HELD ON OCTOBER 20, 2005, BETWEEN THE U.S. NUCLEAR REGULATORY COMMISSION (NRC) STAFF AND AMERGEN ENERGY COMPANY, LLC REPRESENTATIVES TO DISCUSS THE RESULTS OF THE SCOPING AND SCREENING METHODOLOGY AUDIT FOR THE OYSTER CREEK NUCLEAR GENERATING STATION LICENSE RENEWAL APPLICATION On October 20, 2005, the NRC staff met with members of AmerGen Energy Company, LLC (the applicant) in a public meeting to discuss the results of the scoping and screening methodology audit supporting the review of the license renewal application (LRA) for the Oyster Creek Nuclear Generating Station. The application was submitted by letter dated July 22, 2005.
The list of attendees is provided in Enclosure 1.
The NRC staff provided an overview of the areas reviewed during the audit, as well as the results of the review. The staff determined the applicant used a sound, well organized scoping and screening methodology, and that the scoping and screening process was implemented consistent with the applicants procedures. There were four areas in which additional information will be requested: (1) the technical basis for crediting 11 grouted wall penetration as an equivalent anchor for small bore piping; (2) verify that underground piping was not credited as an anchor that is equivalent to a seismic anchor; (3) describe the Quality Assurance program for the combustion turbines; and (4) verify scoping of support systems using plant and industry experience. The staff also answered numerous questions from the public regarding the methods used during the Oyster Creek audit and the license renewal process in general.
/RA/
Donnie J. Ashley, Project Manager License Renewal Branch A Division of License Renewal Office of Nuclear Reactor Regulation Docket No.: 50-219
Enclosures:
As stated cc w/encls: See next page DISTRIBUTION: See next page Adams Accession No.: ML053200460 DOCUMENT NAME:E:\\Filenet\\ML053200460.wpd OFFICE:
LA:RLEP PM:RLEP SC:RLEP NAME:
YEdmonds DAshley LLund DATE:
11/10/05 11/15/05 11/16/05 OFFICIAL RECORD COPY
Oyster Creek Nuclear Generating Station cc:
Chief Operating Officer AmerGen Energy Company, LLC 4300 Winfield Road Warrenville, IL 60555 Senior Vice President - Nuclear Services AmerGen Energy Company, LLC 4300 Winfield Road Warrenville, IL 60555 Site Vice President - Oyster Creek Nuclear Generating Station AmerGen Energy Company, LLC P.O. Box 388 Forked River, NJ 08731 Vice President - Mid-Atlantic Operations AmerGen Energy Company, LLC 200 Exelon Way, KSA 3-N Kennett Square, PA 19348 John E. Matthews, Esquire Morgan, Lewis, & Bockius LLP 1111 Pennsylvania Avenue, NW Washington, DC 20004 Kent Tosch, Chief New Jersey Department of Environmental Protection Bureau of Nuclear Engineering CN 415 Trenton, NJ 08625 Vice President - Licensing and Regulatory Affairs AmerGen Energy Company, LLC 4300 Winfield Road Warrenville, IL 60555 Vice President - Operations Support AmerGen Energy Company, LLC 4300 Winfield Road Warrenville, IL 60555 Regional Administrator, Region I U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406-1415 Mayor of Lacey Township 818 West Lacey Road Forked River, NJ 08731 Senior Resident Inspector U.S. Nuclear Regulatory Commission P.O. Box 445 Forked River, NJ 08731 Director - Licensing and Regulatory Affairs AmerGen Energy Company, LLC 200 Exelon Way, KSA 3-E Kennett Square, PA 19348 Manager Licensing - Oyster Creek Exelon Generation Company, LLC 200 Exelon Way, KSA 3-E Kennett Square, PA 19348 Plant Manager Oyster Creek Nuclear Generating Station AmerGen Energy Company, LLC P.O. Box 388 Forked River, NJ 08731 Regulatory Assurance Manager Oyster Creek AmerGen Energy Company, LLC P.O. Box 388 Forked River, NJ 08731 Vice President, General Counsel and Secretary AmerGen Energy Company, LLC 2301 Market Street, S23-1 Philadelphia, PA 19101 Ron Bellamy, Region I U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406-1415
Oyster Creek Nuclear Generating Station cc:
Correspondence Control Desk AmerGen Energy Company, LLC P.O. Box 160 Kennett Square, PA 19348 License Renewal Manager Exelon Generation Company, LLC 200 Exelon Way, Suite 210 Kennett Square, PA 19348 Mr. James Ross Nuclear Energy Institute 1776 I Street, NW, Suite 400 Washington, DC 20006-3708 Mr. Christopher M. Crane President and Chief Nuclear Officer AmerGen Energy Company, LLC 4300 Winfield Road Warrenville, IL 60555
DISTRIBUTION: Note to Licensee - Amergen Energy, re: Summary of mtg held on 10/20/05 Dated: November 16, 2005 ADAMS Accession No.: ML053200460 HARD COPY RLEP RF E-MAIL:
RidsNrrDrip RidsNrrDe G. Bagchi K. Manoly W. Bateman J. Calvo R. Jenkins J. Fair RidsNrrDssa RidsNrrDipm D. Thatcher R. Pettis G. Galletti D. Shum K. Winsberg (RidsOgcMailCenter)
R. Weisman M. Mayfield A. Murphy S. Smith (srs3)
S. Duraiswamy Y. L. (Renee) Li RLEP Staff C. Holden R. Laufer P. Tam R. Bellamy, RI R. Cureton, RI J. Lilliendahl, RI M. Modes, RI M. Sykes, RI A. Hodgdon OPA Attendance List for Meeting between the U.S. Nuclear Regulatory Commission Staff and AmerGen Energy Company, LLC Representatives October 20, 2005 Name Organization Donnie J. Ashley U.S. Nuclear Regulatory Commission (NRC)
Greg S. Galletti NRC Stephen Tingen NRC Marvin Sykes NRC Richard Pinney New Jersey DEP Joan Richards Office of Congressman Jim Saxton Bud Swenson Exelon Jim Laird Exelon Tom Armstrong Exelon Jhansi Kandasamy Exelon Vinod Aggarwal Exelon Pam Cowan Exelon Fred Polaski Exelon/AmerGen John G. Hufnagel Exelon/AmerGen Pete Resler Exelon/AmerGen Rachelle Benson Exelon/AmerGen Paula Gotsch GRAMMES Judy Brown GRAMMES Mark Dykoff Lacy Twsp Deputy Mayor Ed Frydendahl Manchester NJ John Oddu PPL Susquehanna Lou Ramos PPL Susquehanna Joe Scopelliti PPL Susquehanna Michael B. Delamour PPL Susquehanna Michael Masciale Lacey Resident Lucille Masciale Lacey Resident Terry Matthews Lacey Resident Jean Matthews Lacey Resident Marie S. Kruger Lacey Resident Michelle Perry Times - Beacon Newspapers Brian Prince Asbury Park Press Joanie M. Parks none listed Joe Lamb none listed Herbert Wright none listed Gladys Anderson none listed Ron Watson none listed