ML053120277

From kanterella
Jump to navigation Jump to search
Special Report, Channel 12 of the Containment Hydrogen Monitoring System Inoperable for Scheduled Preventive Maintenance
ML053120277
Person / Time
Site: Nine Mile Point Constellation icon.png
Issue date: 10/31/2005
From: O'Connor T
Constellation Energy Group
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
NMPIL 1998
Download: ML053120277 (2)


Text

Constellation Energy:

Nine Mile Point Nuclear Station P.O. Box 63 Lycoming, NY 13093 October 31, 2005 NMP1L 1998 U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555-0001

SUBJECT:

Nine Mile Point Unit 1 Docket No. 50-220 License No. DPR-63 Special Report, Channel #12 of the Containment Hydrogen Monitoring System Inoperable for Scheduled Preventive Maintenance Gentlemen:

In accordance with Action 4.a of Nine Mile Point Unit 1 Technical Specification Table 3.6.11-2, "Accident Monitoring Instrumentation Action Statements," Nine Mile Point Nuclear Station, LLC, is submitting the following Special Report concerning inoperability of Channel #12 of the Containment Hydrogen Monitoring (CHM) System.

Description of Event On October 17, 2005, at approximately 0312 hours0.00361 days <br />0.0867 hours <br />5.15873e-4 weeks <br />1.18716e-4 months <br />, operators declared Channel #12 of the CHM System inoperable to perform scheduled preventive maintenance.

The redundant Channel #11 was verified to be operable prior to removal of Channel #12 from service.

Cause of Inoperabilitv Channel #12 of the CHM System was removed from service to support scheduled preventive maintenance which required replacement of the bypass and analyzer cabinet solenoid operated valves.

Page 2 NMP1L 1998 Actions Taken Post maintenance testing was performed satisfactorily and Channel #12 of the CHM System was restored to operable status on October 24, 2005, at approximately 0954 hours0.011 days <br />0.265 hours <br />0.00158 weeks <br />3.62997e-4 months <br />.

Should you have any questions regarding this submittal, please contact James Hutton, Director Licensing, at (315) 349-1041.

TJO/RF/sac cc:

Mr. S. J. Collins, NRC Regional Administrator, Region I Mr. L. M. Cline, NRC Senior Resident Inspector