ML052630545

From kanterella
Jump to navigation Jump to search
Comments to the Pbnp License Renewal SER with Open Items (Appendix E)
ML052630545
Person / Time
Site: Point Beach  
(DPR-024)
Issue date: 06/10/2005
From: Veronica Rodriguez
NRC/NRR/DRIP/RLEP
To:
Rodriguez V, RLEP/DRIP/NRR, 415-2232
Shared Package
ML052630524 List:
References
Download: ML052630545 (1)


Text

DSER Section Appendix E Page, Section, and Paragraph DSER Text Suggested Revision Justification Category Page E-2, Section 2, Item No. 31 License Renewal Drawings, Main and Reheat Steam System, LR-2201, Sheets 1 and 3, LR-201, Sheets 1 and 3 License Renewal Drawings, Main and Reheat Steam System, LR-M-2201, Sheets 1 and 3, LR-M-201, Sheets 1 and 3 Generic comment 2

Page E-3, Section 2, Item No. 38 License Renewal Drawings, Emergency Power System, LR-209, Sheets 12, 14 and 15, LR-219, Sheets 1, 2 and 3, LR-226, Sheets 1 and 2, MKW-6090F03001, Sheet 1, MKW-6090F04001, Sheet 1, and Figures 12.2.3, 12.2.4, 12.2.5, 12.2.6 (GT TM)

License Renewal Drawings, Emergency Power System, LR-M-209, Sheets 12, 14 and 15, LR-M-219, Sheets 1, 2 and 3, LR-M-226, Sheets 1 and 2, MKW-6090F03001, Sheet 1, MKW-6090F04001, Sheet 1, and Figures 12.2.3, 12.2.4, 12.2.5, 12.2.6 (GT TM)

Generic comment 2

Page E-3, Section 2, Item No. 39 NUREG-1800, Standard Review Plan for Review of License Renewal Applications for Nuclear Power Plants, April 2001 Redundant - Also Item 1 on page E-1 2

Page E-3, Section 3, Item No. 44 NRC Order EA-003-09, The First Revised NRC Order EA-03-009, February 20, 2004 NRC Order EA-03-009, The First Revised NRC Order EA-03-009, February 20, 2004 Clarification 2