August 26, 2005 LICENSEE:

Nuclear Management Company, LLC FACILITY:

Palisades Nuclear Plant

SUBJECT:

SUMMARY

OF TELEPHONE CONFERENCE HELD ON AUGUST 11, 2005, BETWEEN THE U.S. NUCLEAR REGULATORY COMMISSION (NRC)

AND NUCLEAR MANAGEMENT COMPANY, LLC, CONCERNING DRAFT REQUESTS FOR ADDITIONAL INFORMATION PERTAINING TO THE PALISADES NUCLEAR PLANT, LICENSE RENEWAL APPLICATION The NRC staff (the staff) and representatives of Nuclear Management Company, LLC (NMC) held a telephone conference on August 11, 2005, to discuss and clarify the staffs draft requests for additional information (D-RAIs) concerning the Palisades Nuclear Plant (PNP),

license renewal application. The conference call was useful in clarifying the intent of the staffs D-RAIs. provides a listing of the conference call participants. Enclosure 2 contains a listing of the D-RAIs discussed with the applicant, including a brief description on the status of the items.

The applicant had an opportunity to comment on this summary.

/RA/

Michael J. Morgan, Project Manager License Renewal Section A License Renewal and Environmental Impacts Program Division of Regulatory Improvement Programs Office of Nuclear Reactor Regulation Docket No.: 50-255

Enclosures:

As stated cc w/encls: See next page

DOCUMENT NAME: E:\\Filenet\\ML052430773.wpd OFFICE PM:RLEP LA:RLEP SC:RLEP NAME MMorgan YEdmonds S Lee (R. Auluck for)

DATE 08/26/2005 08/26/2005 08/26/2005

Palisades Nuclear Plant cc:

Robert A. Fenech, Senior Vice President Nuclear, Fossil, and Hydro Operations Consumers Energy Company 1945 Parnall Rd.

Jackson, MI 49201 Arunas T. Udrys, Esquire Consumers Energy Company 1 Energy Plaza Jackson, MI 49201 Regional Administrator, Region III U.S. Nuclear Regulatory Commission 801 Warrenville Road Lisle, IL 60532-4351 Supervisor Covert Township P.O. Box 35 Covert, MI 49043 Office of the Governor P.O. Box 30013 Lansing, MI 48909 U.S. Nuclear Regulatory Commission Resident Inspectors Office Palisades Plant 27782 Blue Star Memorial Highway Covert, MI 49043 Michigan Department of Environmental Quality Waste and Hazardous Materials Division Hazardous Waste and Radiological Protection Section Nuclear Facilities Unit Constitution Hall, Lower-Level North 525 West Allegan Street P.O. Box 30241 Lansing, MI 48909-7741 David Lewis Pillsbury Winthrop Shaw Pittman, LLP 2300 N Street, NW Washington, DC 20037 Manager, Regulatory Affairs Nuclear Management Company, LLC 27780 Blue Star Memorial Highway Covert, MI 49043 Director of Nuclear Assets Consumers Energy Company Palisades Nuclear Plant 27780 Blue Star Memorial Highway Covert, MI 49043 John Paul Cowan Executive Vice President & Chief Nuclear Officer Nuclear Management Company, LLC 700 First Street Hudson, WI 54016 Jonathan Rogoff, Esquire Vice President, Counsel & Secretary Nuclear Management Company, LLC 700 First Street Hudson, WI 54016 Douglas E. Cooper Senior Vice President - Group Operations Palisades Nuclear Plant Nuclear Management Company, LLC 27780 Blue Star Memorial Highway Covert, MI 49043

Palisades Nuclear Plant cc:

Paul A. Harden Site Vice President Palisades Nuclear Plant 27780 Blue Star Memorial Highway Covert, MI 49043 Robert A. Vincent Licensing Lead - License Renewal Project Palisades Nuclear Plant 27780 Blue Star Memorial Highway Covert, MI 49043 Darrel G. Turner License Renewal Project Manager Palisades Nuclear Plant 27780 Blue Star Memorial Highway Covert, MI 49043 Mr. James Ross Nuclear Energy Institute 1776 I Street, NW, Suite 400 Washington, DC 20006-3708 Mr. Douglas F. Johnson Director, Plant Life Cycle Issues Nuclear Management Company, LLC 700 First Street Hudson, WI 54016 Secretary Federal Energy Regulatory Commission 888 First Street, NE, Room 1A Washington, DC 20426 Chairperson Michigan Public Service Commission PO Box 30221 Lansing, MI 48909-7721

DISTRIBUTION: Summary of telephone conference held on August 11, 2005 with NMC, Dated: August 26, 2005 ADAMS Accession No.: ML052430773 HARD COPY RLEP RF M. Morgan (PM)

E-MAIL:

RidsNrrDrip RidsNrrDe G. Bagchi K. Manoly W. Bateman J. Calvo R. Jenkins J. Fair RidsNrrDssa RidsNrrDipm D. Thatcher R. Pettis G. Galletti C. Li K. Winsberg (RidsOgcMailCenter)

R. Weisman M. Mayfield A. Murphy S. Smith (srs3)

S. Duraiswamy Y. L. (Renee) Li RLEP Staff P. Lougheed, RIII J. Ellegood, RIII M. Garza, RIII A. Stone, RIII D. Jaffe L. Raghavan T. Mensah OPA LIST OF PARTICIPANTS FOR TELEPHONE CONFERENCE TO DISCUSS THE PALISADES NUCLEAR PLANT LICENSE RENEWAL APPLICATION AUGUST 11, 2005 Participants Affiliations Michael J. Morgan U.S. Nuclear Regulatory Commission (NRC)

Juan Ayala NRC Tanya Ford NRC Ronald Young NRC Larry Seamans Nuclear Management Company, LLC (NMC)

Robert Vincent NMC Malcolm Patterson Information Systems Laboratories, Inc. (ISL)

Shazia Faridi ISL Diane Mlynarczyk ISL Farideh Saba ISL DRAFT REQUESTS FOR ADDITIONAL INFORMATION (D-RAI)

PALISADES NUCLEAR PLANT LICENSE RENEWAL APPLICATION AUGUST 11, 2005 The U.S. Nuclear Regulatory Commission staff (the staff) and representatives of Nuclear Management Company, LLC (NMC), held a telephone conference call on August 11, 2005, to discuss and clarify the staffs draft requests for additional information (D-RAIs) concerning the Palisades Nuclear Plant, license renewal application (LRA). The following D-RAIs were discussed during the telephone conference call.

D-RAI 2.3.1-2 Scoping boundary drawing LR-M-201, Sheet 2 indicates pressurizer safety valves are in scope of license renewal. However, LRA Table 2.3.1-1 does not identify pressurizer safety valves separately as being within scope. Please indicate which line item in LRA Table 2.3.1-1 includes the subject component.

Discussion: The applicant indicated that the question is clear. This D-RAI will be sent as a formal RAI.

D-RAI 2.3.2-1(b)

Containment sump screens are normally used in the containment sump which provides water for the Emergency Core Cooling System (ECCS) recirculation phase, and one of the intended functions is to protect the ECCS pumps from debris and cavitation due to harmful vortex following a Loss of Coolant Accident (LOCA). The subject component was not identified as within scope in Table 2.3.2-1 of the LRA, which listed component groups for the Engineered Safeguards System that require an Aging Management Review (AMR). Please provide justification why containment sump screens are not in scope or submit an AMR for the stated component.

Discussion: The applicant indicated that the requested information is located in the stated LRA table and the component is listed as piping/strainers. Therefore, this question is WITHDRAWN and will not be sent as a formal RAI.

D-RAI 2.3.2-2 On page 2-71 of the LRA it states, the portions of the Engineered Safeguards System containing components subject to an AMR include accumulators, heat exchangers, fasteners, baskets, pipe and fittings, pumps, and valves. However, in LRA Table 2.3.2-1 and supplemental letter dated May 5, 2005, accumulators are not identified as within scope. Please provide justification why accumulators are not in scope or submit an AMR for the stated component.

Discussion: The applicant indicated that the requested information is located in the stated LRA table and the component is listed as piping/strainers/accumulators. Therefore, this question is WITHDRAWN and will not be sent as a formal RAI.

D-RAI 2.3.2-3 On page 2-71 of the LRA it states the major components of the seven mechanical subsystems of the Engineered Safeguards System. However, in LRA Table 2.3.2-1 and supplemental letter dated May 5, 2005, the following components are not identified as within scope. Please provide justification why the following components are not in scope or submit an AMR for the stated components.

(a) LPCI control valves (b) LPCI injection header (c) Containment Spray headers Discussion: The applicant indicated that the question is clear. This D-RAI will be sent as a formal RAI.

D-RAI 2.3.3-1 Scoping boundary drawing LR-M-202, Sheets 1 and 1A indicate boric acid pumps and filters are in scope of license renewal. However, LRA Table 2.3.3-1 does not identify boric acid pumps and filters as being within scope. Please indicate which line item in LRA Table 2.3.3-1 includes the subject components.

Discussion: The applicant indicated that the question is clear. This D-RAI will be sent as a formal RAI.