June 2005 Monthly Operating Report for Donald C. Cook Nuclear Plant Units 1 and 2
ML052070694
Person / Time
Site: Cook  American Electric Power icon.png
Issue date: 07/15/2005
From: Jensen J
Indiana Michigan Power Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
AEP:NRC:2691-56
Download: ML052070694 (8)


Text

Indiana Michigan Power INDIANA Cook Nuclear Plant MICHIGAN One Cook Place P

Bridgman, MI 49106 POE R'~E AEP~com A unit ofAmerican Electric Power July 15, 2005 AEP:NRC:2691-56 Docket Nos.

50-315 50-316 U. S. Nuclear Regulatory Commission Attn: Document Control Desk Mail Stop O-P 1-17 Washington, DC 20555-0001 Donald C. Cook Nuclear Plant Units 1 and 2 MONTHLY OPERATING REPORT In accordance with the requirements of Donald C. Cook Nuclear Plant Unit 1 and Unit 2 Technical Specification 6.9.1.8, the attached Monthly Operating Report for June 2005 is submitted.

There are no new commitments associated with this submittal.

Should you have any questions, please contact Mr. Michael K. Scarpello, Regulatory Affairs Supervisor, at (269) 466-2649.

Sincerely, h N. Jensen Site Vice President JEN/jen Attachment

U. S. Nuclear Regulatory Commission AEP:NRC:2691-56 Page 2 c: R. Aben - Department of Labor and Economic Growth ANI Nuclear Engineering Department L. Brandon - MDEQ - WHMD/HWRPS D. P. Fadel M. J. Finissi G. T. Gaffhey-Canton R. A. F. Harris INPO Records Center J. N. Jensen J. T. King - MPSC B. Lewis - McGraw-Hill Companies D. H. Malin K L. Matheny M. K. Nazar NRC Project Manager - NRR NRC Region III NRC Resident Inspector D. W. Paul - Columbus W. H. Schalk J. A. Zwolinski

N.R.C. OPERATING DATA REPORT DOCKET NO.

50-315 DATE 7/5/2005 COMPLETED BY R. Harris TELEPHONE 269-465-5901 OPERATING STATUS

1. Unit Name D. C. Cook Unit 1 Notes:
2. Reporting Period Jun-05
3. Licensed Thermal Power (MWt) 3304
4. Name Plate Rating (Gross MWe) 1152
5. Design Electrical Rating (Net MWe) 1020
6. Maximum Dependable Capacity(GROSS MWe) 1056
7. Maximum Dependable Capacity (Net MWe) 1000
8. If Changes Occur in Capacity Ratings (Items no. 3 through 7) Since Last Report Give Reasons
9. Power Level To Which Restricted. If Any (Net MWe)
10. Reasons For Restrictions.

This Mo.

Yr.

11. Hours in Reporting Period 720.0
12. No. of Hrs. Reactor Was Critical 720.0
13. Reactor Reserve Shutdown Hours 0.0
14. Hours Generator on Line 690.8
15. Unit Reserve Shutdown Hours 0.0
16. Gross Therm. Energy Gen. (MWH) 2249391.1 11'
17. Gross Elect. Energy Gen. (MWH) 708870.0 3
18. Net Elect. Energy Gen. (MWH) 684352.0 3
19. Unit Service Factor 95.9
20. Unit Availability Factor 95.9
21. Unit Capacity Factor (MDC Net) 95.0
22. Unit Capacity Factor (DER Net) 93.2
23. Unit Forced Outage Rate 0.0
24. Shutdowns Scheduled over Next Six Months (Type,Date,and Duration):

.to Date 4343.0 3600.8 0.0 3547.4 0.0 512002.7 713540.0 588469.7 81.7 81.7 82.6 81.0 0.0 Cumm.

267335.0 186102.0 463.0 183315.9 321.0 551184060.7 178890263.0 172265231.4 69.0 69.0 65.8 64.5 18.0

25. If Shut Down At End of Report Period, Est'd Date of Startup:
26. Units in Test Status (Prior to Commercial Operation):

Forecast Achieved INITIAL CRITICALITY INITIAL ELECTRICITY COMMERCIAL OPERATION

AVERAGE DAILY POWER LEVEL (MWe-Net)

DOCKET NO.

UNIT DATE COMPLETED BY TELEPHONE 50-315 ONE 05-Jul-05 R. Harris 269-465-5901 MONTH Jun-05 AVERAGE DAILY POWER LEVEL AVERAGE DAILY POWER LEVEL DAY DAY 6/1/2005 6/2/2005 6/3/2005 6/4/2005 6/5/2005 6/6/2005 6/7/2005 6/8/2005 6/9/2005 6/10/2005 6/11/2005 6/12/2005 6/13/2005 6/14/2005 6/15/2005 6/16/2005 1016 1012 1021 1022 1019 1014 1013 1008 1007 1004 1005 1004 1006 1003 1009 1009 6/17/2005 6/18/2005 6/19/2005 6/20/2005 6/21/2005 6/22/2005 6/23/2005 6/24/2005 6/25/2005 6/26/2005 6/27/2005 6/28/2005 6/29/2005 6/30/2005 1013 139 144 988 1021 1017 1015 1013 1004 1000 1005 995 995 994

DOCKET NO.

UNIT NAME DATE COMPLETED BY TELEPHONE PAGE 50 - 315 D.C. Cook Unit 1 July 5, 2005 J. Newmiller 269-465-5901 1 of 1 UNIT SHUTDOWNS AND POWER REDUCTIONS - June 2005 METHOD OF SHUTTING LICENSEE DURATION DOWN EVENT SYSTEM COMPONENT CAUSE AND CORRECTIVE ACTION NO.

DATE TYPE' HOURS REASON2 REACTOR 3 REPORT NO.

CODE4 CODE5 TO PREVENT RECURRENCE 353 050618 S

29.2 B

4 N/A EL EC Reactor power was reduced to approximately 8% to repair the Main Generator Voltage Regulator.

1 TYPE:

F: Forced S: Scheduled 2 REASON:

A: Equipment Failure (Explain)

B: Maintenance or Test C: Refueling D: Regulatory Restriction E: Operator Training and License Examination F: Administrative G: Operational Error (Explain)

H: Other (Expl5ain) 3 METHOD:

1: Manual 2: Manual Scram 3: Automatic Scram 4: Other (Explain) 4 SYSTEM:

Exhibit G - Instructions for preparation of data entry sheets for Licensee Event Report (LER) File (NUREG 0161) 5 COMPONENT:

Exhibit l: Same Source

N.R.C. OPERATING DATA REPORT DOCKET NO.

50-316 DATE 7/5/2005 COMPLETED BY R. Harris TELEPHONE 269-465-5901 OPERATING STATUS

1. Unit Name D. C. Cook Unit 2 Notes:
2. Reporting Period Jun-05
3. Licensed Thermal Power (MWt) 3468
4. Name Plate Rating (Gross MWe) 1133
5. Design Electrical Rating (Net MWe) 1090
6. Maximum Dependable Capacity(GROSS MWe) 1100
7. Maximum Dependable Capacity (Net MWe) 1060
8. If Changes Occur in Capacity Ratings (Items no. 3 through 7) Since Last Report Give Reasons
9. Power Level To Which Restricted. If Any (Net MWe)
10. Reasons For Restrictions.

This Mo.

Yr. to Date Cumm.

11. Hours in Reporting Period 720.0 4343.0 241481.0
12. No. of Hrs. Reactor Was Critical 720.0 4318.0 160067.2
13. Reactor Reserve Shutdown Hours 0.0 0.0 0.0
14. Hours Generator on Line 720.0 4308.4 156070.7
15. Unit Reserve Shutdown Hours 0.0 0.0 0.0
16. Gross Therm. Energy Gen. (MWH) 2494337.1 14869659.9 493751997.6
17. Gross Elect. Energy Gen. (MWH) 805720.0 4925610.0 160241178.0
18. Net Elect. Energy Gen. (MWH) 780162.0 4773004.0 154576418.6
19. Unit Service Factor 100.0 99.2 65.3
20. Unit Availability Factor 100.0 99.2 65.3
21. Unit Capacity Factor (MDC Net) 102.2 103.7 61.5
22. Unit Capacity Factor (DER Net) 99.4 100.8 59.8
23. Unit Forced Outage Rate 0.0 0.0 22.1
24. Shutdowns Scheduled over Next Six Months (Type,Date,and Duration):
25. If Shut Down At End of Report Period, Est'd Date of Startup:
26. Units in Test Status (Prior to Commercial Operation):

Forecast Achieved INITIAL CRITICALITY INITIAL ELECTRICITY COMMERCIAL OPERATION

AVERAGE DAILY POWER LEVEL (MWe-Net)

DOCKET NO.

UNIT DATE COMPLETED BY TELEPHONE 50-316 TWO 5-Jul-05 R. Harris 269-465-5901 MONTH Jun-05 DAY 6/1/2005 6/2/2005 6/3/2005 6/4/2005 6/5/2005 6/6/2005 6/7/2005 6/8/2005 6/9/2005 6/10/2005 6/11/2005 6/12/2005 6/13/2005 6/14/2005 6/15/2005 6/16/2005 AVERAGE DAILY POWER LEVEL 1110 1100 1106 1099 1098 1089 1086 1091 1067 1075 1081 1070 1073 1079 1077 1092 DAY 6/17/2005 6/18/2005 6/19/2005 6/20/2005 6/21/2005 6/22/2005 6/23/2005 6/24/2005 6/25/2005 6/26/2005 6/27/2005 6/28/2005 6/29/2005 6/30/2005 AVERAGE DAILY POWER LEVEL 1071 1100 1102 1107 1096 1068 1109 1054 1072 1066 1075 1063 1066 1068

DOCKET NO.

UNIT NAME DATE COMPLETED BY TELEPHONE PAGE 50 - 316 D.C. Cook Unit 2 July 5, 2005 J. Newmiller 269-465-5901 1 of I UNIT SHUTDOWNS AND POWER REDUCTIONS - June 2005 METHOD OF SHUTTING LICENSEE DURATION DOWN EVENT SYSTEM COMPONENT CAUSE AND CORRECTIVE ACTION NO.

DATE TYPE' HOURS REASON2 REACTOR 3 REPORT NO.

CODE4 CODE5 TO PREVENT RECURRENCE None.

1 TYPE:

F: Forced S: Scheduled 2 REASON:

A: Equipment Failure (Explain)

B: Maintenance or Test C: Refueling D: Regulatory Restriction E: Operator Training and License Examination F: Administrative G: Operational Error (Explain)

H: Other (Explain) 3 METHOD:

1: Manual 2: Manual Scram 3: Automatic Scram 4: Other (Explain) 4 SYSTEM:

Exhibit G - Instructions for preparation of data entry sheets for Ucensee Event Report (LER) File (NUREG 0161) 5 COMPONENT:

Exhibit l: Same Source