AJ RJ 0 Point Beach Nuclcar Plant PBNP SHUTDOWN SAFETY ASSESSMENT AND FIRE CONDITION CHECKLIST Date:
May 12. 2004 Time:
1400 Preparer:
Jon Leiker
(::.U I
R 28 NOTE:
Refer to base procedure NP 10.3.6for safety assessment checklist AKSF definitions.
NOTE:
-Ifien ever fuel has been removedfront the reactor vessel and refueling cavitl, all key safety functions are GREEN except spent fuel pool cooling.
KEY SAFETY FUNCTION CRITERIA: No/False = 0, Yes/True = 1 through 4 REACTIVITY
- 1.
RCS Boron concentration = 3000 ppm a.)
For RSD, RCS boron >Refueling boron concentration specified in unit-specific COLR (TRM 2.1) >2200 ppm b.)
For CSD and prior to RSD no fuel motion, RCS boron > boron concentration required by OP 3C
- 2.
Number of boration paths
- 3.
No fuel motion
- 4.
SR instrumentation operable Subtotal Condition RED ORANGE
-y.jWd=
(0-1)
I (0-2) 2 (0-1) 1 (0-1) 1 0-1 2
04 CD Subtotal =
5 CORE COOLING Subtotal Condition
- 1.
Number of SG available for DHR (0-2) 0 0-1 RED
- 2.
Refueling cavity filled (0-1) 1 2
ORANGE
- 3.
Number of trains RHR available (0-2) 2 XELL
_X
- 4.
RCS level above REDUCED INVENTORY (0-1) 1 5GREEN RCS Temperature =777F; 39 days shutdown; RCS Level = Rod Latch Height; Reactor Is refueled Subtotal =
4 RCS Time to Boil 30 hrs (Applicable at Cold or Refueling Shutdown)
POWER AVAILABILITY Subtotal Condition I.
Independent off-site power sources I
RED available to A-05 and A-06 (totally 2
ORANGE independent at the 4160 V, 13.8 kV, 3
i and 345 kV levels)
(0-2) 2 (5
d m
- 2.
G-01 or G-021A-051B-03 available (0-1) 1 G-03 or G-04/A-061B-04 available (0-1) 1
- 3.
G-05 available, Reactor Cavity filled to Ž 23 ft above the top of the reactor vessel flange, upper internals removed and RCS time to boil 2 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.
(0-1) 0 Subtotal =
4 INVENTORY Subtotal Condition 0-1 RED
- 1.
Pressurizer level 220 percent w/head on (0-1) 0 2
ORANGE
- 2.
Refueling Cavity filled (see definition)
(0-3) 2 3
T V
- 3.
RCS level above REDUCED INVENTORY (0-1) 1 (I)
- 4.
Makeup from VCT/BLENDER and/or RWST available (0-2) 1 Subtotal =
4 PBF-1562 Revision 2 10/30/02 In womfcwuie t, Freedom of Informaton A ex L
Page 1 of 9
References:
NP 10.3.6 NP 10.2.1
Point Beach Nuclear Plant PBNP SHUTDOWN SAFETY ASSESSMENT AND FIRE CONDITION CHECKLIST CONTAINMENT
- 1.
Containment integrity (TS 15.1.D) (Containment Operable) {ITS TS 3.6.11 )set
- 2.
Containment Closure CL-lE maintained and closure < time to boil
- 3.
No fuel motion
- 4.
DHR Capability:
cavity flooded and internals out OR at least one SG available OR one fan cooler with Equip hatch installed and personnel hatches capable of being shut (O or 4) 0 (O or 2) 2 (0-1) 1 Subtotal 0
2d) 4-5-6 Condition RED (0-1) 0 Subtotal =
3 SPENT FUEL POOL COOLING (ONLY APPLICABLE when starting AND during FULL CORE OFFLOADS)
NOTE:
Take credit for only one P-12 independent offsite power source during periods of single X-03 or X-04 availability (*).
"A" SFP cooling pump available with power available from:
G-02 or G-01 via 2B-32
, (*) an independent off-site power source different than that for Train B below
- 2.
"B" SFP cooling pump available with power available from:
G-03 or G-04 via IB42
-(*) an independent off-site power source different than that for Train A above
- 3.
Temporary power available to one SFP cooling pump, G-05 available, and SFP time to boil 2 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.
Subtotal 0-1 2
3 4-5 Condition RED ORANGE YELLOW GREEN (0-1)
NA (0-1)
NA (0-1)
NA (0-1)
NA (0-1)
NA SFP Temperatures:
NW NA OF SE NA OF SFP Average Temp NA SFP Time to Boil NA Subtotal =
NA GIVE A BRIEF EXPLANATION OF ANY CHANGE IN SAFETY ASSESSMENT THAT TOOK PLACE:
Refueling cavity at Rod Latch Height. Rod Latching is complete.
Look-ahead: When Cavity is drained to below Rod Latch height, we will lose one point for Core Cooling (go YELLOW) and two points for Inventory (if CVCS is not yet back, I recommend using the RNYST4RHR flowpath for Inventory instead of Reactivity to keep Inventory YELLOW and turn Reactivity YELLOW).
PBF-1562 Revision 2 10/30102
References:
NP 10.3.6 NP 10.2.1 Page 2 of 9
Point Beach Nuclear Plant PBNP SHUTDOWN SAFETY ASSESSMENT AND FIRE CONDITION CHECKLIST OUTAGE SAFETY ASSESSMENT UNIT:
1 DATE:
May 12, 2004 TIME:
1400 KEY SAFETY FUNCTIONS:
REACTIVITY:
CORE. COOLING:
POWER AVAILABLE:
INVENTORY:
CONTAINMENT:
SFP COOLING:
GREEN GREEN GREEN GREEN YELLOW NA*
PROTECTED EOUIPMENT:
v-B RCS Time to Boil is 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />. Using NP 10.3.6 Time To Boil curves.
Fire Protection Condition III: Credit is taken for fire rounds as fire prevention contingency 9+*
PBF-1562 Revision 2 10130/02
References: