I lul Point Beach Nuclear Plant PBNP SHUTDOWN SAFETY ASSESSMENT AND FIRE CONDITION CHECKLIST Date:
April 23, 2004 Time:
0300 Preparer:
Mike LeGreve U
I R
28 NOTE:
Refer to base procedure NP 10.3.6for safety assessment checklist KSFdefinitions.
NOTE:
117heneverfuel has been removed front the reactor vessel and refueling cavit, all key safetyfunctions are GREEN excent spentfuelpool cooling.
KEY SAFETY FUNCTION CRITERIA: No/False = 0, Yes/True = I through 4 REACTIVITY
- 1.
RCS Boron concentration = 2889 ppm a.)
For RSD, RCS boron >Refueling boron concentration specified in unit-specific COLR (TRM 2.1) >2200 ppm b.)
For CSD and prior to RSD no fuel motion, RCS boron > boron concentration required by OP 3C
- 2.
Number of boration paths
- 3.
No fuel motion
- 4.
SR instrumentation operable Subtotal Condition RED 9QAAL
<;ZD (0-1) 1 (0-2) 2 (0-1) 0 (0-1) 1 0-1 2
3-4 5
Subtotal 4
CORE COOLING Subtotal Condition
- 1.
Number of SG available for DHR (0-2) 0 0-1 RED
- 2.
Refueling cavity filled (0-1) 1 2
ORANGE
- 3.
Number of trains RHR available (0-2) 2 3
- 4.
RCS level above REDUCED INVENTORY (0-1) 1 4-5 RCS TEMP = 95'F; 20 days shutdowyn, Subtotal 4
RCS Level - Control Rod Latch Height RCS Time to Boil 19 hrs (Applicable at Cold or Refueling Shutdown)
POWVER AVAILABILITY Subtotal Condition
- 1.
Independent off-site power sources I
RED available to A-05 and A-06 (totally 2
ORANGE independent at the 4160 V, 13.8 kY, 3
and 345 kV levels)
(0-2) 2 4-5.
- 2.
G-01 or G-02/A-05B-03 available (0-1) 1 G-03 or G-04/A-06/B-04 available (0-1) 1
- 3.
G-05 available, Reactor Cavity filled to 2 23 Pt above the top of the reactor vessel flange, upper internals removed and RCS time to boil 2 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.
(0-1) 0 Subtotal 4
INVENTORY Subtotal Condition
- 1.
Pressurizer level 220 percent wlhead on 0-1 RED (0-1) 0 2
ORANGE
- 2.
Refueling Cavity filled (see definition)
(0-3) 1 31
- 3.
RCS level above REDUCED INVENTORY (0-1) 1 4
- 4.
Makeup from VCTIBLENDER and/or RWST available (0-2) 2 Subtotal =
4 Information in this rornrnm w-n ra a n e _ h i e F e d o n fn Act exe re f Information PBF-1562 FrOr a
Revision 2 10/30102 Page I of 9
References:
NP 10.3.6 NP 10.2.1
-G-t03
Point Beach Nuclear Plant PBNP SHUTDOWN SAFETY ASSESSMENT AND FIRE CONDITION CHECKLIST CONTAINMENT
- 1.
Containment integrity (TS 15.1.D) (Containment Operable) (ITS TS 3.6.1} set
- 2.
Containment Closure CL-lE maintained and closure < time to boil
- 3.
No fuel motion
- 4.
DHR Capability:
cavity flooded and internals out OR at least one SG available OR one fan cooler wit3 Equip hatch installed and personnel hatches capable of being shut (O or 4) 0 (O or 2) 2 (0-1) 0 V\\
Subtotal 0
l 2-3 4-5-6 Condition RED anAc =
(0-1) 1 Subtotal =
3 SPENT FUEL POOL COOLING (ONLY APPLICABLE when starting AND during FULL CORE OFFLOADS)
NOTE:
Take creditor only one P-12 independent offsite power source duringperlods of singleX-03 or X-04 availablty (').
Subtotal Condition
- 1.
"A" SFP cooling pump available 0-1 RED with power available from:
2 ORANGE G-02 or G-0I via 2B-32 (0-1) n/a 3
YELLOW t) an independent off-site power 4-5 GREEN source different than that for Train B below
- 2.
"B" SFP cooling pump available with power available from:
G-03 or G004 via IB-42 an independent off-site power source different than that for Train A above
- 3.
Temporary power available to one SFP cooling pump, G-05 available, and SFP time to boil Ž 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.
(0-1) n/a (0-1) n/a (0-1) n/a (0-1) n/a SFP Temperatures:
NW n/a OF SE n/a DF SFP Average Temp n/a SFP.Time to Boil n/a Subtotal =
n/a GIVE A BRIEF EXPLANATION OF ANY CHANGE IN SAFETY ASSESSMENT THAT TOOK PLACE:
Core Cooling and Inventory changed to GREEN once reactor cavity water level reached the rod latch height, 4/22 @ 1830 (verification completed at 1945).
Reactivity and Containment Key Functions both changed to YELLOW upon start of Control Rod Unlatching, 4/23 @ 0201.
Reactivity and Containment will return to GREEN upon completion of rod unlatching and then again turn YELLOW for upper internals lift.
PBF-1562 Revision 2 10/30/02
References:
NP 10.3.6 NP 10.2.1 Page 2 of 9
Point Beach Nuclear Plant PBNP SHUTDOWN SAFETY ASSESSMENT AND FIRE CONDITION CHECKLIST OUTAGE SAFETY ASSESSMENT UNIT:
1 DATE:
April 23, 2004 TIME:
0300 KEY SAFETY FUNCTIONS:
REACTIVITY:
CORE COOLING:
POWER AVAILABLE:
INVENTORY:
CONTAINMENT:
SFP COOLING:
YELLOW GREEN GREEN GREEN YELLOW NA PROTECTED EOUIPNIIENT:
Uniti IsinMode6 Fire Protection Condition IV: Credit is taken for fire rounds as fire prevention contingency RCS Time to Boil is 19 hours2.199074e-4 days <br />0.00528 hours <br />3.141534e-5 weeks <br />7.2295e-6 months <br /> RCS Cavity Level is at Rod Latch Height Hot Leg Vent Path Is the Pressurizer manway PBF-1562 Revision2 103002
References:
NP 103.6 NP 102.1 Page 5 of 9