ML051740210
| ML051740210 | |
| Person / Time | |
|---|---|
| Site: | Salem |
| Issue date: | 06/30/2005 |
| From: | Stewart Bailey NRC/NRR/DLPM/LPD1 |
| To: | Levis W Public Service Enterprise Group |
| Bailey S N,NRR/DLPM,415-1321 | |
| References | |
| GL-04-001, TAC MC4847 | |
| Download: ML051740210 (3) | |
Text
June 30, 2005 Mr. William Levis Senior Vice President & Chief Nuclear Officer PSEG Nuclear LLC-X04 Post Office Box 236 Hancocks Bridge, NJ 08038
SUBJECT:
SALEM NUCLEAR GENERATING STATION, UNIT NO. 1 - RESPONSE TO GENERIC LETTER 2004-01, REQUIREMENTS FOR STEAM GENERATOR TUBE INSPECTIONS (TAC NO. MC4847)
Dear Mr. Levis:
On August 30, 2004, the Nuclear Regulatory Commission (NRC) issued Generic Letter (GL) 2004-01, Requirements For Steam Generator Tube Inspections. The purpose of GL 2004-01 was to obtain information that would enable the NRC staff to determine whether licensees steam generator (SG) tube inspection programs comply with the existing tube inspection requirements (the plant technical specifications in conjunction with Appendix B to Part 50 of Title 10 of the Code of Federal Regulations).
By letter dated October 29, 2004, PSEG Nuclear, LLC (PSEG) responded to GL 2004-01 for Salem Nuclear Generating Station (Salem), Unit Nos. 1 and 2. The staffs review of your response to the GL did not identify any concerns with the inspection practices employed at Salem, Unit No. 1. The staff, therefore, concludes that your SG tube inspection practices for Salem, Unit No. 1 are in compliance with the existing tube inspection requirements. The NRC staffs review of your response to GL 2004-01 for Salem, Unit No. 2 is still ongoing. A request for additional information regarding your response to the GL for Salem, Unit No. 2 was forwarded to PSEG by letter dated May 23, 2005.
If you have any questions regarding this matter, please contact me at (301) 415-1321.
Sincerely,
/RA/
Stewart Bailey, Senior Project Manager, Section 2 Project Directorate I Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No. 50-272
Mr. William Levis Senior Vice President & Chief Nuclear Officer PSEG Nuclear LLC-X04 Post Office Box 236 Hancocks Bridge, NJ 08038
SUBJECT:
SALEM NUCLEAR GENERATING STATION, UNIT NO. 1 - RESPONSE TO GENERIC LETTER 2004-01, REQUIREMENTS FOR STEAM GENERATOR TUBE INSPECTIONS (TAC NO. MC4847)
Dear Mr. Levis:
On August 30, 2004, the Nuclear Regulatory Commission (NRC) issued Generic Letter (GL) 2004-01, Requirements For Steam Generator Tube Inspections. The purpose of GL 2004-01 was to obtain information that would enable the NRC staff to determine whether licensees steam generator (SG) tube inspection programs comply with the existing tube inspection requirements (the plant technical specifications in conjunction with Appendix B to Part 50 of Title 10 of the Code of Federal Regulations).
By letter dated October 29, 2004, PSEG Nuclear, LLC (PSEG) responded to GL 2004-01 for Salem Nuclear Generating Station (Salem), Unit Nos. 1 and 2. The staffs review of your response to the GL did not identify any concerns with the inspection practices employed at Salem, Unit No. 1. The staff, therefore, concludes that your SG tube inspection practices for Salem, Unit No. 1 are in compliance with the existing tube inspection requirements. The NRC staffs review of your response to GL 2004-01 for Salem, Unit No. 2 is still ongoing. A request for additional information regarding your response to the GL for Salem, Unit No. 2 was forwarded to PSEG by letter dated May 23, 2005.
If you have any questions regarding this matter, please contact me at (301) 415-1321.
Sincerely,
/RA/
Stewart Bailey, Senior Project Manager, Section 2 Project Directorate I Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No. 50-272 Distribution:
Public PKlein LLund MBanerjee CRaynor DRoberts PDI-2/RF MYoder DCollins SBailey ECobey ADAMS Accession No.: ML051740210
- Memo provided; no substantive changes made.
Office PDI-2/LA PDI-2/PM EMCB/SC*
PDI-2/SC Name CRaynor SBailey LLund DRoberts Date 6/17/05 6/17/05 2/21/2005 6/30/05 OFFICIAL COPY
Salem Nuclear Generating Station, Unit Nos. 1 and 2 cc:
Mr. Michael Gallagher Vice President - Eng/Tech Support PSEG Nuclear P.O. Box 236 Hancocks Bridge, NJ 08038 Mr. Thomas P. Joyce Site Vice President - Salem PSEG Nuclear P.O. Box 236 Hancocks Bridge, NJ 08038 Ms. Christina L. Perino Director - Regulatory Assurance PSEG Nuclear - N21 P.O. Box 236 Hancocks Bridge, NJ 08038 Mr. George H. Gellrich Plant Support Manager PSEG Nuclear P.O. Box 236 Hancocks Bridge, NJ 08038 Jeffrie J. Keenan, Esquire PSEG Nuclear - N21 P.O. Box 236 Hancocks Bridge, NJ 08038 Lower Alloways Creek Township c/o Mary O. Henderson, Clerk Municipal Building, P.O. Box 157 Hancocks Bridge, NJ 08038 Dr. Jill Lipoti, Asst. Director Radiation Protection Programs NJ Department of Environmental Protection and Energy CN 415 Trenton, NJ 08625-0415 Brian Beam Board of Public Utilities 2 Gateway Center, Tenth Floor Newark, NJ 07102 Regional Administrator, Region I U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 Senior Resident Inspector Salem Nuclear Generating Station U.S. Nuclear Regulatory Commission Drawer 0509 Hancocks Bridge, NJ 08038 Mr. Carl J. Fricker Plant Manager PSEG Nuclear - N21 P.O. Box 236 Hancocks Bridge, NJ 08038