ML051460417
| ML051460417 | |
| Person / Time | |
|---|---|
| Site: | Point Beach (DPR-024, DPR-027) |
| Issue date: | 05/24/2005 |
| From: | - No Known Affiliation |
| To: | Office of Nuclear Reactor Regulation |
| References | |
| FOIA/PA-2004-0282 | |
| Download: ML051460417 (2) | |
Text
Inspection Scope Commitment/Plans Lower Head (4/6/04) 100 % visual (VT-2) of bare head. Will use VT-2 qualified people.
Upper Head (4/10-15/04) 100 % visual (VT-2) of bare head 100 % UT of all penetrations (including leak path verification), with the exception of vent line.
Penetrant examination of vent line.
WE - Contractor inspecting two SGs.
Predict 59 AVB in SG 1A.
Predict 29 AVB in SG 1 B.
Deepest flaw (wear) left in service tube 35,56 at 27% predicted to reach 39% max.
100% full length bobbin 50% of hot leg tubes at top of tube sheet (+/- 2 inch) by MRPC Plus Point 50% of row 1 U-bends MRPC Plus Point.
Special interest MRPC Plus Point as required.
ISI Program (4/8/04 & 4/14/04)
Exam Area Code NDE meth Procedure Start Date Cat/item 007900 B-D.
VOL NDE-171 4/8 Pzr Surge Nozzle IR 83.120 047500 R-A VOL NDE-173 4/8 RC-10-PZR-1001-05 R1.11 Pipe to elbow 047600 R-A VOL NDE-173 4/8 RC-10-PZR-1001-06 R1.1I Pipe to elbow 074600 R-A VOL NDE-173 4/8 RC-03-PS-1001-08 R1.20 Pipe to elbow
Exam Area Code NDE meth Procedure Start Date Cat/item 074700 R-A VOL NDE-173 4/8 RC-03-PS-1001-09 R1.20 Pipe to elbow 075600 R-A VOL NDE-173 4/8 RC-03-PS-1001-10 RI.20 Pipe to elbow 075700 R-A VOL NDE-173 4/8 RC-03-PS-1001-11 R1.20 Pipe to elbow 204600 C-B SUR NDE 350 4/14 SG 1B Feedwater C.2.21 VOL NDE-163 Nozzle to Shell weld 323700 (loop B FW)
R-A VOL NDE-172 4/14 FW-16-FW-1002%.15 R1.11 Valve 1CS476BB to elbow 448200 (AFW to B SG)
R-A VOL NDE-109 4/14 AF-03-AFW-1002-76 R1.11 NDE172 Flange to pipe 448200 (AFW to B SG)
R-A VOL NDE-109 4/14 AF-03-AFW-1002-77 R1.11 NDE172 Pipe to Branch Conn Plant Code ISI interval Start Date J
End Date Point Beach 1998 Edition, 00 Fourth 7/1/2002 6/30/2012 U1&U2 266/301 Addenda RR#3 Risk Informed ISI Class 1 & 2 Piping. Code Case N-578 and EPRI TR-112657 approved in July of 2003.