Final Accident Sequence Precursor Analysis of the March 7, 2003, Operational Event
ML051450484
Person / Time
Site: Nine Mile Point 
(DPR-063)
Issue date: 06/01/2005
From: Tam P
NRC/NRR/DLPM/LPD1
To: Spina J
Nine Mile Point
Tam P, NRR/DLPM, 415-1451
Shared Package
ML051520476 List:
References
IR-03-003, TAC MA7651
Download: ML051450484 (3)


Text

June 1, 2005 Mr. James A. Spina Vice President Nine Mile Point Nine Mile Point Nuclear Station, LLC P.O. Box 63 Lycoming, NY 13093

SUBJECT:

NINE MILE POINT NUCLEAR STATION, UNIT NO. 1 - FINAL ACCIDENT SEQUENCE PRECURSOR ANALYSIS OF MARCH 7, 2003, OPERATIONAL EVENT (TAC NO. MA7651)

Dear Mr. Spina:

Enclosed for your information is the final Accident Sequence Precursor (ASP) analysis of an operational event which occurred at the Nine Mile Point Nuclear Station, Unit No. 1 on March 7, 2003. The condition was documented in Nuclear Regulatory Commission (NRC)

Inspection Report No. 50-220/2003-0030, dated April 15, 2003. This is being issued as a final analysis since it is a non-controversial, lower-risk precursor for which the ASP results are consistent with the results from the Significance Determination Process final evaluation of the same condition. Elimination of the review and comment resolution for this event will reduce the burden for the NRC staff and the licensee.

Please contact me at 301-415-1451 if you have any questions regarding the enclosure.

Sincerely,

/RA/

Peter S. Tam, Senior Project Manager, Section 1 Project Directorate I Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No. 50-220

Enclosure:

As stated cc w/encl: See next page

June 1, 2005 Mr. James A. Spina Vice President Nine Mile Point Nine Mile Point Nuclear Station, LLC P.O. Box 63 Lycoming, NY 13093

SUBJECT:

NINE MILE POINT NUCLEAR STATION, UNIT NO. 1 - FINAL ACCIDENT SEQUENCE PRECURSOR ANALYSIS OF MARCH 7, 2003, OPERATIONAL EVENT (TAC NO. MA7651)

Dear Mr. Spina:

Enclosed for your information is the final Accident Sequence Precursor (ASP) analysis of an operational event which occurred at the Nine Mile Point Nuclear Station, Unit No. 1 on March 7, 2003. The condition was documented in Nuclear Regulatory Commission (NRC)

Inspection Report No. 50-220/2003-0030, dated April 15, 2003. This is being issued as a final analysis since it is a non-controversial, lower-risk precursor for which the ASP results are consistent with the results from the Significance Determination Process final evaluation of the same condition. Elimination of the review and comment resolution for this event will reduce the burden for the NRC staff and the licensee.

Please contact me at 301-415-1451 if you have any questions regarding the enclosure.

Sincerely,

/RA/

Peter S. Tam, Senior Project Manager, Section 1 Project Directorate I Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No. 50-220

Enclosure:

As stated cc w/encl: See next page DISTRIBUTION:

PUBLIC R. Laufer D. Skay J. Trapp, R-1 PD Reading P. Tam G. DeMoss, RES R. Summers OGC S. Little ACRS Accession No.: ML051450484 Enclosure Accession No.: ML051190518 Package Accession No: ML051520476 OFFICE PDI-1\\PM PDI-1\\LA PDI-1\\PM RES/DRAA PDI-1/SC NAME PTam SLittle DSkay CAder*

RLaufer DATE 5/31/05 5/31/05 5/31/05 5/11/05 6/1/05

OFFICIAL RECORD COPY

Nine Mile Point Nuclear Station, Unit No. 1 cc:

Mr. Michael J. Wallace President Nine Mile Point Nuclear Station, LLC c/o Constellation Energy Group 750 East Pratt Street Baltimore, MD 21202 Mr. Mike Heffley Senior Vice President and Chief Nuclear Officer Constellation Generation Group 1997 Annapolis Exchange Parkway Suite 500 Annapolis, MD 21401 Regional Administrator, Region I U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 Resident Inspector U.S. Nuclear Regulatory Commission P.O. Box 126 Lycoming, NY 13093 Charles Donaldson, Esquire Assistant Attorney General New York Department of Law 120 Broadway New York, NY 10271 Mr. Paul D. Eddy Electric Division NYS Department of Public Service Agency Building 3 Empire State Plaza Albany, NY 12223 Mr. Peter R. Smith, President New York State Energy, Research, and Development Authority 17 Columbia Circle Albany, NY 12203-6399 Mark J. Wetterhahn, Esquire Winston & Strawn 1400 L Street, NW Washington, DC 20005-3502 Supervisor Town of Scriba Route 8, Box 382 Oswego, NY 13126 Carey W. Fleming, Esquire Senior Counsel Constellation Generation Group, LLC 750 East Pratt Street, 17th Floor Baltimore, MD 21202 Ms. Deb Katz, Executive Director Nuclear Security Coalition c/o Citizens Awareness Network P.O. Box 83 Shelburne Falls, MA 01370