PAM Instrumentation 3.3.3.1 SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 3.3.3.1.1


NOTE---------------------

Applicable for each Function in Table 3.3.3.1-1.

Perform CHANNEL CHECK.

31 days SR 3.3.3.1.2 Deleted SR 3.3.3.1.3


NOTE---------------------

Applicable for each Function in Table 3.3.3.1-1.

Perfo____CANELCALIBRAT__O_._____onhs Perform CHANNEL CALIBRATION.

1B months I

CLINTON 3.3-21 Amendment No. 164

PAM Instrumentation 3.3.3.1 Table 3.3.3.1-1 (page 1 of 1)

Post Accident Monitoring Instrumentation CONDITIONS REFERENCED FROM REOUIRED REQUIRED FUNCTION CITUELS ACTION D.1

1. Reactor Steam Dome Pressure 2

E

2. Reactor Vessel Water Level 2

E

3. Suppression Pool Water Level
a. High Range 2

E

b. Low Range 2

E

4.

Drywell Pressure 2

E

5. Primary Containment Area Radiation 2

F

6. Drywell Area Radiation 2

F

7. Penetration Plow Path, Automatic PCIV Position 2 per penetration E

flow, path "

S. Deleted

9. Primary Containment Pressure
a. High Range 2

E

b. Low Range 2

E

10. Suppression Pool Water Bulk Average Temperature 21cE I

(a) Not required for isolation valves whose associated penetration flow path is isolated.

(b) Only one position indication channel is required for penetration flow paths with only one installed control room indication channel.

(c) Monitoring each quadrant.

CLINTON 3.3 -22 Amendment No. 164

3.6.3.1 3.6 CONTAINMENT SYSTEMS 3.6.3.1 Deleted CLINTON 3.6-36 Amendment No164

3.6.3.1 This page intentionally blank CLINTON 3.6-37 Amendment No.164