ML051090255

From kanterella
Jump to navigation Jump to search
Supplemental Information Regarding Outage 2003 Inservice Inspection Report R.E. Ginna Nuclear Power Plant
ML051090255
Person / Time
Site: Ginna Constellation icon.png
Issue date: 04/14/2005
From: Korsnick M
Constellation Energy Group
To: Skay D
Document Control Desk, Office of Nuclear Reactor Regulation
References
Download: ML051090255 (2)


Text

Maria Korsnick 1503 Lake Road Vice President Ontario, New York 14519-9364 585.771.3494 585.771.3943 Fax maria.korsnick~constellation.com Constellation Energy R.E. Ginna Nuclear Power Plant April 14,2005 Ms. Donna M. Skay Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555

Subject:

Supplemental Information Regarding Outage 2003 Inservice Inspection Report R.E. Ginna Nuclear Power Plant Docket No. 50-244

Reference:

(a) Letter from Robert C. Mecredy (RG&E) to Robert L. Clark (NRC), 'Transmittal of Inservice Inspection Report for the Fourth Interval (2000-2009), Second Period, First Outage (2003) - ISI and First Interval (1997-2008), Second Period, Second Outage (2003) - IWE/IWL ", dated January 13, 2004.

(b) Letter from Robert C. Mecredy (RG&E) to Allen R. Johnson (NRC), "Transmittal of Inservice Inspection Report for the Third Interval (1990-1999)",

dated August 17, 1990.

(c) Letter from Robert C. Mecredy (RG&E) to Allen R. Johnson (NRC), "Transmittal of Inservice Inspection Report for the Third Interval (1990-1999)", Second Period, Third Outage (1995) dated August 2, 1995.

Dear Ms. Skay:

In Reference (a), the results of the R.E. Ginna Nuclear Power Plant inservice inspections for the refueling outage conducted in 2003 were submitted. As the result of recent discussions with the NRC staff, R.E. Ginna Nuclear Power Plant, LLC would like to provide the following informnation.

1.

With regards to Weld RC-273-I, the Weld ISI Summary Number is 005000. The last time that the weld was examined was in 1990. The results of the 1990 examination are as follows:

PT: no recordable indications UT: no recordable indications These examination results were documented within Reference (b), Attachment 1, Page 1.

/00162q/

2.

With regards to Weld RC-1 000-MSW-1, the Weld ISI Summary Number is 004800. The last time that the weld was examined was in 1995. The results of the 1995 examination are as follows:

PT: insignificant - 1 indication, L=0, W=1/8", UP, 1/16" round UT: no recordable & geometry - ID geometry These examination results were documented within Reference (c), NIS-1 Section, Page 3.

3.

Welds RC-273-I and RC-1000-MSW-1 do not contain Alloy 600/690 material. These welds are stainless.

4.

There were no rejectable indications found in Alloy 600/690 materials during the current (2005) outage.

Any questions concerning this submittal should be directed to Thomas Harding, Nuclear Safety and Licensing at (585) 771-3384.

V truly yours, Mary G. orsick xc:

Ms. Donna M. Skay (Mail Stop 0-8-C2)

Project Directorate I Division of Licensing Project Management Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission One White Flint North 11555 Rockville Pike Rockville, MD 20852 Regional Administrator, Region I U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 U.S. NRC Ginna Senior Resident Inspector