MONTHYEARML23181A0342023-07-11011 July 2023 Summary of Classification Meeting with TMI-2 Solutions, LLC Regarding the Process for Consultation Under Section 106 of the National Historic Preservation Act of 1966 as Related to the Historic and Culture Resources Review License Amendment ML19326A3152019-12-0303 December 2019 Summary of November 18, 2019, Meeting with Exelon Generation Company, LLC Regarding a Planned Request for an Alternative to Supplemental Valve Position Indication Testing Requirements ML19191A1882019-07-0909 July 2019 Joint Annual Assessment Meeting (Webinar) for Pennsylvania Power Plants - Meeting Summary ML19162A0272019-06-21021 June 2019 Summary of June 4, 2019, Meeting with Exelon Generation Company, LLC Regarding a Planned Request to Extend the Test Interval for Safety Relief Valves ML19036A8832019-02-0707 February 2019 Summary of Meeting with Exelon Generation Company, LLC Regarding a Planned Request to Use ASME Code Case N-879 ML18354B1712019-01-0202 January 2019 Summary of December 19, 2018, Meeting with Exelon Generation Company, LLC Regarding the Use of Boiling Water Reactor Vessel and Internals Project Guidelines ML18325A1712018-11-28028 November 2018 Summary of Meeting with Exelon Generation Company, LLC Regarding Planned Fleet License Amendment Request to Revise Technical Specifications for High Radiation Areas ML18120A1772018-05-0101 May 2018 Summary of Meeting with Exelon Generation Company, LLC Regarding Draft Guidance for Emergency Response Organization Staffing ML18108A0652018-04-18018 April 2018 Annual Assessment Meeting Summary and Attendance List 2018 ML17132A2592017-05-19019 May 2017 TMI Annual Assessment Meeting (4-20-17) Summary ML16228A0622016-08-15015 August 2016 Summary of July 26, 2016, Public Meeting on Status of Associated Effects Submittals Related to the Reevaluated Flood Hazards at Exelon Generation Company, LLC Sites as Part of the Response to Near-Term Task Force Recommendation 2.1, Floodin ML16085A3292016-04-0606 April 2016 Summary of March 22, 2016, Meeting with Exelon Generation Company, LLC, on Proposed License Amendment Request to Adopt ANSI 3.1-2014 Operating Training Standards ML16091A0782016-03-31031 March 2016 Annual Assessment Meeting Summary on 03/23/2016 ML16040A2182016-02-11011 February 2016 January 21, 2016, Summary of Meeting with Exelon Generation Company, LLC Licensing Managers ML15350A1962015-12-30030 December 2015 Summary of the Conference Call Regarding Fall 2015 Steam Generator Tube Inservice Inspection ML15089A1642015-04-27027 April 2015 Summary of February 25, 2015, Partially Closed Meeting with Industry Stakeholders Regarding the Babcock and Wilcox Loss of Coolant Accident Evaluation Model Analysis ML15104A6382015-04-14014 April 2015 Summary of Annual Assessment Meeting - Three Mile Island Nuclear Station, Unit 1 ML14304A7832014-11-14014 November 2014 Public Meeting with the U.S. Nuclear Regulatory Commission and Exelon Generation Company, LLC Regarding Generic Letter 2004-02, Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents at Pressurized-Wate ML14133A0592014-07-0101 July 2014 Summary of Closed Meeting Between Representatives of the Army Corps of Engineers, Nuclear Regulatory Commission, Federal Energy Regulatory Commission, Exelon Generation Co, LLC, and PPL Susquehanna, LLC, to Discuss Dam Failure Analysis.. ML14119A0292014-04-29029 April 2014 Annual Assessment Meeting Summary for April 17, 2014 ML14015A3562014-01-24024 January 2014 Summary of Conference Calls Regarding the Fall 2013 Steam Generator Tube Inservice Inspection ML13262A1632013-09-23023 September 2013 Meeting Report - Three Mile Island, Unit 2, Post-Shutdown Decommissioning Activities Report Public Meeting ML13179A0932013-07-17017 July 2013 6/17/2013 - Summary of Meeting with Exelon to Discuss Recent Once-Through Steam Generator Tube-to-Tube Wear at Three Mile Island, Unit 1 ML13141A6372013-05-21021 May 2013 5/7/2013 - Summary of Annual Assessment Meeting - Three Mile Island ML12110A3112012-05-0303 May 2012 4/10/2012 Summary of Public Meeting with Exelon Generation Company, LLC Regarding Its Future Submittal of Technical Specification Changes of Licensed Operator Eligibility Requirements ML12117A0022012-04-25025 April 2012 ROP-12 Annual Assessment Meeting Summary ML1202704162012-02-13013 February 2012 1/26/2012 - Summary of Meeting with Entergy and Exelon to Discuss Recent Once-Through Steam Generator Inservice Inspection Results ML1135501672011-12-28028 December 2011 Summary of Conference Calls with Exelon Generation Company, LLC to Discuss 2011 Steam Generator Tube Inspections ML1116500712011-06-14014 June 2011 Summary of Three Mile Island Annual Assessment Meeting, June 7, 2011 ML1108109722011-03-25025 March 2011 Summary of March 14, 2011, Meeting with Exelon to Discuss Proposed Main Steam Safety Valve License Amendment Request ML1036305532011-01-0606 January 2011 Summary of Meeting (Teleconference) with Exelon to Discuss RAI Regarding the Implementation of an Emergency Action Level Scheme Based on NEI 99-01, Rev. 5 ML1031902892010-11-22022 November 2010 Summary of October 19, 2010 NRC Petition Board Meeting for 2.206 Petition Regarding TMI-2 Decommissioning Funding Financial Assurance ML1020700252010-07-27027 July 2010 Summary of Category 1 Meeting with Exelon to Discuss Re-Submittal of Its Cyber Security Plan ML1015301202010-05-27027 May 2010 Memo Annual Assessment Meeting Summary for Three Mile Island ML0930804802009-11-19019 November 2009 Meeting Summary of 10/22/2009 Meeting Regarding Its Power Uprate Project Plan ML0930104552009-11-0303 November 2009 Once-Through Steam Generator Tube Loads Under Conditions Resulting from Postulated Breaks in Reactor Coolant System Upper Hot-Leg Large-Bore Piping ML0929501582009-11-0202 November 2009 Summary of Category 1 Public Meeting with Exelon to Discuss Generic Letter 2004-02 Supplemental Response Request for Additional Information ML0929406112009-11-0202 November 2009 Summary of Category 1 Public Meeting with Exelon to Discuss Proposed Control Rod Drive Control System License Amendment Request ML0926705032009-09-30030 September 2009 Summary of Meeting with Exelon to Discuss Generic Letter 2004-02 Supplemental Response Request for Additional Information ML0922505512009-08-21021 August 2009 Summary of August 11, 2009, Meeting with Exelon to Discuss Generic Letter 2004-02 Supplemental Response Request for Additional Information ML0919803632009-08-20020 August 2009 Summary of Licensing Counterparts Meeting with Exelon Generation Company, to Discuss Licensing Practices and Processes ML0912801592009-05-0707 May 2009 TMI Annual Assessment Meeting 4/2/09 - Summary ML0906204192009-03-0909 March 2009 02/24/2009 Summary of Public Meetings on the Draft Supplemental Environmental Impact Statement Regarding the Three Mile Island Nuclear Station, Unit 1, License Renewal Review (TAC No. MD7702) Ltr ML0833100732008-11-26026 November 2008 Summary of Meeting with Exelon to Review the Results of Security Organization Safety Conscious Work Environment (SCWE) Surveys at Exelon Nuclear Operating Reactors ML0830900532008-11-17017 November 2008 License Renewal Application, Summary of Conference Call with Amergen Energy Company Regarding Responses to Request for Additional Information for Sections 2.3.3 and 2.3.4 ML0826821322008-10-10010 October 2008 Summary of Meeting with Amergen to Discuss Planned License Amendment Request Relating to Rod Control System Replacement ML0821207272008-08-0505 August 2008 07/17/2008 Summary of Telephone Conference Call Between the NRC and Amergen Energy Company, Llc., Concerning Follow-up Questions Pertaining to Three Mile Island, Unit 1 License Renewal Environmental Review and Site Audit ML0815606662008-06-12012 June 2008 Summary of Conference Call with Amergen Energy Company, LLC, to Discuss the Severe Accident Mitigation Alternatives Requests for Additional Information for Three Mile Island Nuclear Station, Unit 1 ML0812007572008-06-0202 June 2008 Summary of Category 1 Meeting with Exelon to Discuss Current and Planned Licensing Activities and Processes ML0813606482008-05-22022 May 2008 05/01/08 Summary of Public Environmental Scoping Meetings Related to the Review of the Three Mile Island, Unit 1, License Renewal Application 2023-07-11
[Table view] |
Text
April 28, 2005 LICENSEE: AmerGen Energy Company, LLC (AmerGen)
FACILITY: Three Mile Island Nuclear Station, Unit 1 (TMI-1)
SUBJECT:
SUMMARY
OF FEBRUARY 16-17, 2005, CATEGORY 1 WORKING-LEVEL MEETING WITH AMERGEN TO DISCUSS THE LICENSEES TMI-1 STEAM GENERATOR (SG) KINETIC EXPANSION (KE) INSPECTION AND ACCEPTANCE CRITERIA On February 16-17, 2005, a public meeting was held between the U.S. Nuclear Regulatory Commission (NRC), and representatives of AmerGen, the licensee for TMI-1, and Exelon Generation Company, LLC, in the NRC Headquarters, located at One White Flint North, 11555 Rockville Pike, Rockville, Maryland. The purpose of the meeting was to conduct a working-level discussion of the licensees response to the NRC staffs issues with the licensees TMI-1 SG KE inspection and acceptance criteria report dated October 4, 2002, as supplemented August 16, 2004 (Agencywide Documents Access and Management System (ADAMS) Accession Nos.
ML022840503 and ML042370131).
AmerGen presented information on the history and background of the installed KEs and the schedule for replacement of SGs at TMI-1. The licensee addressed the seven categories of the NRC staffs issues: (1) suitability of leaving circumferential flaws in service, (2) Leakage assessment including a thermal hydraulic analysis model, (3) the basis for the assumption of no growth/no initiation of new flaws, (4) structural integrity assessment, (5) consistency with recent industry experience, (6) inspection practices/techniques, and (7) other issues, which were enumerated in the meeting agenda attached to the meeting notice (ADAMS Accession No. ML050340182).
The discussions centered on open issues with the criteria which are related to flaws located in the expanded portion of the tube within the hot-leg tubesheet. Two of the major outstanding issues pertain to the adequacy of the assumptions and inputs into the thermal hydraulic model and whether the licensee has selected the most limiting accident for assessing the structural and leakage integrity of the tubing. These issues must be resolved before the licensee can adopt the new SG technical specifications which will be the subject of a future NRC staff generic communication.
The licensee indicated a number of new commitments which would be formalized in the next revision of the KE inspection and acceptance criteria report including plugging circumferential cracks in the pressure boundary, conducting a 100% scope inspection each outage until SG replacement, and plugging of new indications.
CONTACT: T. Colburn, NRR 301-415-1402 tgc@nrc.gov
AmerGen No members of the public other than the licensee were in attendance. No licensee attendees chose to complete any Public Meeting Feedback Forms (NRC Form 659) which were available at the meeting. is a list of the meeting attendees, and Enclosure 2 is a copy of the licensees slides presented at the meeting.
Please direct any inquiries to Timothy G. Colburn, Senior Project Manager, at 301-415-1402, or tgc@nrc.gov.
/RA/
Timothy G. Colburn, Senior Project Manager, Section 1 Project Directorate I Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No. 50-289
Enclosures:
- 1. List of Attendees
- 2. Licensees Handout cc w/encls: See next page
ML050970295 OFFICE PDI-1/PM PDI-2/LA EMCB\SC PDI-1/SC NAME TColburn MOBrien LLund RLaufer DATE 04/18/05 04/19/05 04/27/05 04/28/05 LIST OF ATTENDEES CATEGORY 1 WORKING-LEVEL MEETING WITH AMERGEN ENERGY COMPANY, LLC KINETIC EXPANSION INSPECTION AND ACCEPTANCE CRITERIA FOR THREE MILE ISLAND NUCLEAR STATION, UNIT 1, STEAM GENERATOR TUBES FEBRUARY 16-17, 2005 NAME ORGANIZATION
- 1. T. Colburn NRC/NRR/DLPM/PDI-1
- 2. E. Murphy NRC/NRR/EMCB
- 3. K. Karwoski NRC/NRR/EMCB
- 4. C. Khan NRC/NRR/EMCB
- 5. L. Lund NRC/NRR/EMCB
- 6. R. Laufer NRC/NRR/DLPM/PDI-1
- 7. C. Liang NRC/NRR/DSSA/SRXB
- 8. R. Lorson NRC/DRS/RGN-1
- 9. C. Smith EXELON/AMERGEN/TMI-1
- 10. S. Leshnoff EXELON/ENGINEERING
- 11. R. Freeman EXELON/AMERGEN/ENGINEERING
- 12. D. Helker EXELON/LICENSING
- 13. G. Navratil EXELON/AMERGEN/NDE SERVICES
- 14. D. Distel EXELON/LICENSING Enclosure 1
MEETING SLIDES Enclosure 2
Three Mile Island Nuclear Station, Unit 1 cc:
Site Vice President - Three Mile Island Nuclear Director - Licensing and Regulatory Affairs Station, Unit 1 AmerGen Energy Company, LLC AmerGen Energy Company, LLC 200 Exelon Way, KSA 3-E P. O. Box 480 Kennett Square, PA 19348 Middletown, PA 17057 Rich Janati, Chief Senior Vice President - Nuclear Services Division of Nuclear Safety AmerGen Energy Company, LLC Bureau of Radiation Protection 4300 Winfield Road Department of Environmental Protection Warrenville, IL 60555 Rachel Carson State Office Building P.O. Box 8469 Vice President - Operations, Mid-Atlantic Harrisburg, PA 17105-8469 AmerGen Energy Company, LLC 200 Exelon Way, KSA 3-N Plant Manager - Three Mile Island Nuclear Kennett Square, PA 19348 Station, Unit 1 AmerGen Energy Company, LLC Vice President - Licensing and Regulatory Affairs P. O. Box 480 AmerGen Energy Company, LLC Middletown, PA 17057 4300 Winfield Road Warrenville, IL 60555 Regulatory Assurance Manager - Three Mile Island Nuclear Station, Unit 1 Regional Administrator AmerGen Energy Company, LLC Region I P.O. Box 480 U.S. Nuclear Regulatory Commission Middletown, PA 17057 475 Allendale Road King of Prussia, PA 19406 Arthur Burritt, Region I U.S. Nuclear Regulatory Commission Chairman 475 Allendale Road Board of County Commissioners King of Prussia, PA 19406 of Dauphin County Dauphin County Courthouse Michael A. Schoppman Harrisburg, PA 17120 Framatome ANP Suite 705 Chairman 1911 North Ft. Myer Drive Board of Supervisors Rosslyn, VA 22209 of Londonderry Township R.D. #1, Geyers Church Road Vice President, General Counsel and Secretary Middletown, PA 17057 AmerGen Energy Company, LLC 2301 Market Street, S23-1 Senior Resident Inspector (TMI-1) Philadelphia, PA 19101 U.S. Nuclear Regulatory Commission P.O. Box 219 Mr. Christopher M. Crane Middletown, PA 17057 President and Chief Executive Officer AmerGen Energy Company, LLC 4300 Winfield Road Warrenville, IL 60555
Three Mile Island Nuclear Station, Unit 1 cc:
Dr. Judith Johnsrud National Energy Committee Sierra Club 433 Orlando Avenue State College, PA 16803 Eric Epstein TMI Alert 4100 Hillsdale Road Harrisburg, PA 17112 Correspondence Control Desk AmerGen Energy Company, LLC P.O. Box 160 Kennett Square, PA 19348 Manager Licensing - Three Mile Island Nuclear Station, Unit 1 Exelon Generation Company, LLC 200 Exelon Way, KSA 3-E Kennett Square, PA 19348 Associate General Counsel AmerGen Energy Company, LLC 4300 Winfield Road Warrenville, IL 60555