BYRON 2005-0036, Steam Generator Tube Repairs Completed During Refueling Outage 13

From kanterella
(Redirected from ML050950421)
Jump to navigation Jump to search
Steam Generator Tube Repairs Completed During Refueling Outage 13
ML050950421
Person / Time
Site: Byron Constellation icon.png
Issue date: 03/28/2005
From: Kuczynski S
Exelon Generation Co, Exelon Nuclear
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
BYRON 2005-0036
Download: ML050950421 (2)


Text

ExekIn.

Exelon Generation Company, LLC www.exeloncorp.com Nuclear Byron Station 4450 North German Church Road Byron, IL 61010-9794 March 28, 2005 LTR:

BYRON 2005-0036 File:

3.11.0530 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 Byron Station, Unit 1 Facility Operating License No. NPF-37 NRC Docket No. STN 50-454

Subject:

Steam Generator Tube Repairs Completed during the Byron Station, Unit 1, Refueling Outage 13.

Pursuant to Item a of Technical Specification 5.6.9, "Steam Generator (SG) Tube Inspection Reports," we are reporting the number of SG tubes plugged or repaired during Byron Station, Unit 1, Refueling Outage 13.

A 100% full-length eddy current bobbin coil inspection and 20% plus-point inspection of the hot leg top of tubesheet region were performed on all four Unit 1 SGs. 100% of the total population of hot leg dents and dings that were 2.0 volts or greater were also inspected with the plus-point probe in all SGs.

A total of 7 tubes were plugged during the Byron Station, Unit 1, Refueling Outage 13.

Based upon the results of this inspection, all steam generators were classified as inspection category C-1 in accordance with Technical Specification 5.5.9.c, "Inspection Results Classification."

The plugging distribution within the SGs is summarized in the table below.

Steam Tubes Plugged Tubes Total Tubes Generator this Outage Plugged Plugged*

(BI R13)

Previously 1A 1

0 1

1B 1

0 1

IC 0

1 1

iD 5

0 5

Total 7

1 8

  • Each SG contains 6633 tubes k9 S4A

Byron Ltr. 2005-0036 March 21, 2005 Page 2 If there are any questions regarding this information, please contact Mr. W. Grundmann, Regulatory Assurance Manager, at (815) 406-2800.

Respectfully, Stephen E. Kuczynski Site Vice President Byron Nuclear Generating Station SEK/JS/TF/ljs cc:

Regional Administrator - NRC Region IlIl NRC Senior Resident Inspector - Byron Station