Tennessee Valley Authority, Post Office Box 2000, Spring City, Tennessee 37381-2000 MAR 2 3 2005 U.S. Nuclear Regulatory Commission ATTN:
Document Control Desk Washington, D. C. 20555 Gentlemen:
In the Matter of Tennessee Valley Authority
)
Docket No.50-390 WATTS BAR NUCLEAR PLANT (WBN)
UNIT 1 -
CYCLE 6 STEAM GENERATOR (SG)
TUBE INSPECTION -
15 DAY REPORT This letter fulfills the reporting requirements contain in Technical Specification 5.9.9, SG Tube Inspection Report.
In accordance with Technical Specification 5.9.9, listed below are the number of steam generator tubes that were plugged or sleeved during the WBN Unit 1 Cycle 6 refueling outage.
RESULTS OF WBN SG INSERVICE INSPECTION Number of Tubes SG Number Plugged Sleeved 1
124 118 2
183 28 3
120 0
4 179 134 Totals 606 280 4kOq 41 Pied on qcyI paw
U.S. Nuclear Regulatory Commission Page 2 MAR 2 3 2005 There are no regulatory commitments associated with this submittal.
If you have any questions concerning this letter, please contact me at (423) 365-1824.
Sincerely, P. L.
ace Manager, Site Licensing and Industry Affairs Cc:
NRC Resident Inspector Watts Bar Nuclear Plant 1260 Nuclear Plant Road Spring City, Tennessee 37381 Mr. D. V. Pickett, Project Manager U.S. Nuclear Regulatory Commission MS 08G9 One White Flint North 11555 Rockville Pike Rockville, Maryland 20852-2738 U.S. Nuclear Regulatory Commission Region II Sam Nunn Atlanta Federal Center 61 Forsyth St., SW, Suite 23T85 Atlanta, Georgia 30303