Reporting Requirements 5.6 5.0 ADMINISTRATIVE CONTROLS 5.6 Reporting Requirements The following reports shall be submitted in accordance with 10 CFR 50.4.

5.6.1 Not Used 5.6.2 Annual Radioloqical Environmental Oneratina Report I

K.ATC IM'J I =E A single submittal may be made for a multiple unit station. The submittal should combine sections common to all units at the station.

The Annual Radiological Environmental Operating Report covering the operation of the unit during the previous calendar year shall be submitted by May 1 of each year. The report shall include summaries, Interpretations, and analyses of trends of the'results of the radiological environmental monitoring program for the reporting period. The material provided shall be consistent with the objectives outlined In the Offsite Dose Calculation Manual (ODCM), and In 10 CFR 50, Appendix I, Sections IV.B.2, IV.B.3, and IV.C.

The Annual Radiological Environmental Operating Report shall Include the results of analyses of all radiological environmental samples and of all environmental radiation measurements taken during the period pursuant to the locations specified in the table and figures In the ODCM, as well as summarized and tabulated results of these analyses and measurements in a format similar to the table in the Radiological Assessment Branch Technical Position, Revision 1, November 1979. In the event that some individual results are not available for inclusion with the report, the report shall be submitted noting and explaining the reasons for the missing results. The missing data shall be submitted in a supplementary report as soon as possible.

(continued)

DIABLO CANYON - UNITS 1 & 2 5.0-25 Unit I - Amendment No. 4i5, 180 Unit 2 -Amendment No. 445, 182

Reporting Requirements 5.6 5.6 Reporting Requirements (continued) 5.6.3 Radioactive Effluent Release Report go NOTE-A single submittal may be made for a multiple unit station. The submittal shall combine sections common to all units at the station; however, for units with separate radwaste systems, the submittal shall specify the releases of radioactive material from each unit.

The Radioactive Effluent Release Report covering the operation of the unit during the previous year shall be submitted prior to May 1 of each year in accordance with 10 CFR 50.36a. The report shall include a summary of the quantities of radioactive liquid and gaseous effluents and solid waste released from the unit. The material provided shall be consistent with the objectives outlined In the ODCM and Process Control Program and in conformance with 10 CFR 50.36a and 10 CFR 50, Appendix I,Section IV.B.1.

5.6.4 Not Used 5.6.5 CORE OPERATING LIMITS REPORT (COLR)

a.

Core operating limits shall be established prior to each reload cycle, or prior to any remaining portion of a reload cycle, and shall be documented In the COLR for the following:

1.

Shutdown Bank Insertion Limits for Specification 3.1.5,

2.

Control Bank Insertion Limits for Specification 3.1.6,

3.

Axial Flux Difference for Specification 3.2.3,

4.

Heat Flux Hot Channel Factor, K(Z) and W(Z) - Fo(z) (F0RrP Specification 3.2.1),

5.

RCS Flow Rate and Nuclear Enthalpy Rise Hot Channel Factor - F'H (FRTPA and PF&H for Specification 3.2.2),

6.

SHUTDOWN MARGIN values in Specifications 3.1.1, 3.1.4, 3.1.5, 3.1.6, and 3.1.8,

7.

Moderator Temperature Coefficient limits in Specification 3.1.3, and

'8.

Refueling Boron Concentration limits in Specification 3.9.1.

(continued)

DIABLO CANYON - UNITS I & 2 5.0-26 Unit I - Amendment No. 435, 180 Unit 2-Amendment No. 435, 182