ML050830396
| ML050830396 | |
| Person / Time | |
|---|---|
| Site: | Point Beach |
| Issue date: | 05/28/2004 |
| From: | Locke K Nuclear Management Co |
| To: | Chernoff H NRC/NRR/DLPM/LPD3 |
| References | |
| FOIA/PA-2004-0282 | |
| Download: ML050830396 (4) | |
Text
Harold Clhernoff -
Pane 1 A I
A I
I From:
"Locke, Kim" <Kim.Locke@nmcco.com>
To:
<hkc~nrc.gov>
Date:
Fri, May 28, 2004 9:06 AM
<<CAP056265.pdf>>
CC:
Connolly, James W." <James.Connolly~nmcco.com>
I
,6-3.5
I Harold Chernoff - CAP056265.pdf P.....age
%S Nuclear Management Company Page I of 3 B State Change History Initiate AR Pro -Screen Submit to Screening Team AR Screening OueL Screening Update AR Screening Oue 0
413012004 3:08.25 PM 0
5/1/2004 1:40.03 AM
/3/2004 10.28:01 AM by KEMP. BRIAN R Owner (None) by HARPER, RON
°Owner PSNP CAP Admin by ZIFKO. TRACEY ROwner BENNETT, KEVIN r E Section 1 Activity Request Id:
CAP056265 Activity Type:
CAP Submit Date:
413012004 3:08:25 PM 6 One Line
Description:
CRDM Nozzle 26 Possible Flaw Indications 6 Detailed
Description:
4/30/2004 3:08:25 PM - KEMP, BRIAN:
During performance of U1R28 NDE examinations required by NRC Order Issuance of Order Establishing Interim Inspection Requirements for Reactor Pressure Vessel Heads at Pressurized Water Reactors' possible flaw Indications were seen on Nozzle 26.
UT Examination PBNP 's UT examinations are being performed by Areva (formerly Framatome). The UT signal for nozzle 26 shows circumferential Indication In the Jgroove weld area that extends Into the CRDM tube base material.
The Areva UT analyst has concluded that the Indication Is fabrication-related and Is not a result of PWSCC cracking. The final documented Areva Inspection report has not yet been completed. Contact Brian Kemp for detailed Information.
PT Examination As a result of the above-mentioned UT examination, a dye-penetrant (PT) examination of the nozzle 26 CRDM J-groove material was performed. This was done to confirm the conclusion that no PWSCC cracking was occurring In nozzle 26.
The PT exams showed minor surface Indications that require further evaluation. There were two areas identified. The first if these areas are approximately 1 and Yi Inches in length by 5/8 Inches In width. The second area Is approximately 2 and *i Inches In length by 518 Inches In width. Each area Is comprised of several small linear Indications of various lengths. The final documented PT results are not yet Issued. Contact Bill Jensen for PT examination results.
5/612004 10:48:27 AM - KEMP, BRIAN:
Update on Nozzle 28 PBNP Engineering had directed that further examination of the J-grrove surface be performed following minor grinding of the weld surface. These exams have been completed. The results of the exams Indicate that flaws In the weld exist that do not meet the flaw evaluation guidance contained In WCAP-14000 'Structural Integrity Evaluation of Reactor Vessel Upper Head Penetrations to Support Continued Operation: Point Beach Units 1 &
- 2. Additionally, the exiatance of flaws In the weld region do not meet the understood acceptance criteria of NRC Inspection Order EA-03-09.
PBNP-11 Nozzle 26 will be repaired prior to placing the RPV Head back Into service.
Contact Brian Kemp with questions.
Initiator:
KEMP, BRIAN Initiator Department:
EPP Engineering Programs Long Term FI Programs PB ES Date/TIme of Discovery: 4/3012004 2:42:44 PM DatelTime of Occurrence:
413012004 2:42:44 PM Identified By:
Site-identifiec System:
RC PB Equipments (1st):
R-1 PB Equipment Type (1st):
(None)
Equipment 1 (2nd):
(None)
Equipment Type (2nd):
(None)
Equipment U (3rd):
(None)
Equipment Type (3rd):
(None)
Site/Unit:
Point Beach-Unit 1 Why did this occur?:
413012004 3:08:25 PM - KEMP, BRIAN:
U1R28 NDE examinations required by NRC Order 'Issuance of Order Establishing Interim Inspection Requirements for Reactor Pressure Vessel Heads at Pressurized Water Reactors.
Immediate Action Taken: 4/30/2004 3:08:25 PM - KEMP. BRIAN:
Dye-penetrant examination:
Recommendations:
413012004 3:08:25 PM -KEMP, BRIAN:
Evaluate condition and provide direction for resolution. This Item should be assigned to Brian Kemp http:llenwsO2ltmtrackltmtrack.dlI?IssuePage&Template=viewbody&recordid=601I437&tableid=
1 000 51804 5s28/204
I Harold Chernoff - CAP056265.Ddf Page 2A{
3 Nuclear Management Company Page 2 of 3 0 Notify Me During Eval?: N B Section 2 0 SRO Review Required?:
Y Operability Status:
Inoperabhs 0 Compensatory Actions:
N Basis for Operability:
5t1t2004 1:40:03 AM - HARPER. RON:
Needs resolution prior to RCS Fill and Vent.
0 Unplanned TSAC Entry: N E Section 3 Screened?:
N 6 OAINuclear Oversight?:
N i
Good Catch/Well Docd7: NA B Section 4 E 4 restraint.
0 External Notification:
0 Significance Level: B Potential MRFF?:
N 0 Licensing Review?: N N
Inappropriate Action:
Process:
Human Error Type:
Equip Failure Mode:
OrglMgt Failure Mode:
Hot Buttons:
E Section 5 CAP Admin:
- Project:
0 Active/inactive:
6 Owner 0 Last Modifier:
0 Last State Changer:
NUTRK ID:
i of Children:
(None)
Activity:
(None)
Human Pert Fail Mode:
(None)
Process Fail Mode:
(None) 0 Group Causing Prob:
(None)
(None)
(None)
(None)
(None)
BENNETT.KEVIN s
Prescreener Corrective Actn Program (CAP) AR 0 State:
Active O Submitter:
BENNETT. KEVIN 0Last Modified Date:
GADZALA, JACK C Last State Change Date:
HARPER, RON C
0 Close Date:
(None)
AR Screening Que KEMPBRIAN 512212004 10:03:47 AM 5/1/2004 1:40:03 AM 0
Relerences:
Update:
Prescreen Comments:
Import Memo Field:
OPR Completed?:
N OLDACTIONNUM:
sub-tsid:
0 originalssued:
056265 Site:
Point Beach Cartridge and Frame:
original-projectid:
32 E Attachments and Parent/Child Unks
'9 Principal to CE013955:
MODE RESTRAINT 4-CRDM Nozzle 26 Possible Flaw Indications by ZIFKO, TRACEY (51312004 10:30:25 AM)
C Ut R28 Extent of Condition Evaluation for Penetration i 26 at PBNP - signed (425279 bytes) by GADZALA JACK (5/2212004 10:03:46AM)
B Change History http:/Icnws02ltmtrackltmtrack.dII'?IssuePage&Template=viewbody&recordid=601I437&tableid=
1 00051104 5s28n204
Nuclear Management Company Page 3 of 3 51312004 10:28:06 AM by ZIFKO. TRACEY orliginaLpoJecLId Changed From 0 To 32 originaLssue-jd Changed From - To '056265' 51312004 10:30:25 AM by ZIFKO, TRACEY Last Modified Date Changed From 51312004 10:28:06 AM To 513n2004 10:30:25 AM Attachment Added: Principal to CE013955:
MODE RESTRAINT 4"CRDM Nozzle 26 Possible Flaw Indications 5162004 10:46:27AM by KEMP. BRIAN Detailed Description Changed From 0rigInal Texl; To jAppended:j Update on Nozzte 26 PSNP Engineering had directed that further examinalion of the J grrove surtace be performed following minor grinding of the weld surface. These exams have been completed. The results of the exams Indicate that tlawso[..
Last Modified Date Changed From 51312004 10:30:25 AM To 516/2004 10:46:27 AM Last Moddlier Changed From ZtFKO. TRACEY To KEMP. BRIAN 5122/2004 10:03:47 AM by OADZALA, JACK Lost Moddled Date Changed From 51612004 10:46:27 AM To 512212004 10:03:47 AM Last Modifier Changed From KEMP, BRIAN To GADZALA. JACK AttachmentAdded:U1R28ExtentolConditionEvaluationforPenetrationC2BatPBNP
-signed http://enwsO2ltmtrack/tmtrack.dll?lssuePage&Template=viewbody&recordid=601437&tableid= 1000 5/28/2004