Ltr, GL 2004-01 Requirements for SG Tube Inspections (Tac No. MC4844)
ML050830234
Person / Time
Site: Robinson Duke Energy icon.png
Issue date: 03/30/2005
From: Marshall M
NRC/NRR/DLPM/LPD2
To: Moyer J
Carolina Power & Light Co
Patel C P, NRR/DLPM, 415-3025
References
GL-04-001, TAC MC4844
Download: ML050830234 (3)


Text

March 30, 2005 Mr. J. W. Moyer, Vice President Carolina Power & Light Company H. B. Robinson Steam Electric Plant, Unit No. 2 3581 West Entrance Road Hartsville, South Carolina 29550

SUBJECT:

H. B. ROBINSON STEAM ELECTRIC PLANT, UNIT NO. 2 - RESPONSE TO GENERIC LETTER 2004-01, "REQUIREMENTS FOR STEAM GENERATOR TUBE INSPECTIONS" (TAC NO. MC4844)

Dear Mr. Moyer:

On August 30, 2004, the NRC issued Generic Letter (GL) 2004-01, "Requirements For Steam Generator Tube Inspections." The purpose of GL 2004-01 was to obtain information that would enable the NRC staff to determine whether licensees steam generator (SG) tube inspection programs comply with the existing tube inspection requirements (the plant technical specifications in conjunction with Appendix B to Title 10 of the Code of Federal Regulations, Part 50).

By letter dated October 28, 2004, Carolina Power & Light Company responded to GL 2004-01 for H. B. Robinson Steam Electric Plant, Unit No. 2 (HBRSEP2). The NRC staffs review of your response to the GL did not identify any concerns with the inspection practices employed at HBRSEP2. Therefore, we conclude that your SG tube inspection practices are in compliance with the existing tube inspection requirements.

If you have any questions regarding this matter, please contact Chandu Patel at (301) 415-3025.

Sincerely,

/RA/

Michael L. Marshall, Jr., Chief, Section 2 Project Directorate II Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No. 50-261 cc: See next page

ML050830234 NRR-106 OFFICE PDII-2/PM PDII-2/LA PDII-2/SC NAME CPatel EDunnington MMarshall DATE 03/ 22 /2005 03/ 22 /2005 03 / 30 /2005 Mr. J. W. Moyer H. B. Robinson Steam Electric Plant, Carolina Power & Light Company Unit No. 2 cc:

David T. Conley Supervisor, Licensing/Regulatory Programs Associate General Counsel II - Legal H. B. Robinson Steam Electric Plant, Department Unit No. 2 Progress Energy Service Company, LLC Carolina Power & Light Company Post Office Box 1551 3581 West Entrance Road Raleigh, North Carolina 27602-1551 Hartsville, South Carolina 29550 Ms. Margaret A. Force Ms. Beverly Hall, Section Chief Assistant Attorney General N.C. Department of Environment State of North Carolina and Natural Resources Post Office Box 629 Division of Radiation Protection Raleigh, North Carolina 27602 3825 Barrett Dr.

Raleigh, North Carolina 27609-7721 U. S. Nuclear Regulatory Commission Resident Inspectors Office Mr. Robert P. Gruber H. B. Robinson Steam Electric Plant Executive Director 2112 Old Camden Road Public Staff - NCUC Hartsville, South Carolina 29550 4326 Mail Service Center Raleigh, North Carolina 27699-4326 Mr. Dan Stoddard Plant General Manager Mr. Henry H. Porter, Assistant Director H. B. Robinson Steam Electric Plant, South Carolina Department of Health Unit No. 2 Bureau of Land & Waste Management Carolina Power & Light Company 2600 Bull Street 3581 West Entrance Road Columbia, South Carolina 29201 Hartsville, South Carolina 29550 Mr. Chris L. Burton Mr. William G. Noll Manager Director of Site Operations Performance Evaluation and H. B. Robinson Steam Electric Plant, Regulatory Affairs PEB 7 Unit No. 2 Progress Energy Carolina Power & Light Company Post Office Box 1551 3581 West Entrance Road Raleigh, North Carolina 27602-1551 Hartsville, South Carolina 29550 Mr. John H. ONeill, Jr.

Public Service Commission Shaw, Pittman, Potts, & Trowbridge State of South Carolina 2300 N Street NW.

Post Office Drawer 11649 Washington, DC 20037-1128 Columbia, South Carolina 29211 J. F. Lucas Manager - Support Services - Nuclear H. B. Robinson Steam Electric Plant, Unit No. 2 Carolina Power & Light Company 3581 West Entrance Road Hartsville, South Carolina 29550 Mr. C. T. Baucom