ML050740500

From kanterella
Jump to navigation Jump to search

Revision of Core Shroud Support Weld H9 Inspection Scope
ML050740500
Person / Time
Site: Nine Mile Point Constellation icon.png
Issue date: 03/29/2005
From: Tam P
NRC/NRR/DLPM/LPD1
To: Spina J
Nine Mile Point
References
TAC MC5642
Download: ML050740500 (3)


Text

March 29, 2005 Mr. James A. Spina Vice President Nine Mile Point Nine Mile Point Nuclear Station, LLC P.O. Box 63 Lycoming, NY 13093

SUBJECT:

NINE MILE POINT NUCLEAR STATION, UNIT NO. 1 - INSPECTION OF CORE SHROUD SUPPORT WELD H9 INSPECTION SCOPE (TAC NO. MC5642)

Dear Mr. Spina:

By letter dated January 14, 2005, you requested Nuclear Regulatory Commission (NRC) approval of a proposed change to the H9 weld recirculation N1 nozzle locations to be inspected during Refueling Outage 18. Your letter stated that inspection commitments had been agreed to by the NRC staff in its letter dated December 13, 2002.

On March 10, 2005, you revised your January 14, 2005, letter by stating that the proposed change to the H9 weld inspection scope should have been processed as a commitment change using Nuclear Energy Institute 99-04, Guidelines for Managing NRC Commitment Changes as endorsed by NRC Regulatory Issue Summary 2000-17, Managing Regulatory Commitments Made by Power Reactor Licensees to the NRC Staff.

The NRC staff reviewed your letters and agreed that they address a change of inspection scope that can be effected under the commitment management program you referenced.

Accordingly, there is no need for the NRC staff to issue any revision to its previous evaluation.

This closes all efforts covered by the above TAC number.

Sincerely,

/RA/

Peter S. Tam, Senior Project Manager, Section 1 Project Directorate I Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No. 50-220 cc: See next page

Mr. James A. Spina March 29, 2005 Vice President Nine Mile Point Nine Mile Point Nuclear Station, LLC P.O. Box 63 Lycoming, NY 13093

SUBJECT:

NINE MILE POINT NUCLEAR STATION, UNIT NO. 1 - INSPECTION OF CORE SHROUD SUPPORT WELD H9 INSPECTION SCOPE (TAC NO. MC5642)

Dear Mr. Spina:

By letter dated January 14, 2005, you requested Nuclear Regulatory Commission (NRC) approval of a proposed change to the H9 weld recirculation N1 nozzle locations to be inspected during Refueling Outage 18. Your letter stated that inspection commitments had been agreed to by the NRC staff in its letter dated December 13, 2002.

On March 10, 2005, you revised your January 14, 2005, letter by stating that the proposed change to the H9 weld inspection scope should have been processed as a commitment change using Nuclear Energy Institute 99-04, Guidelines for Managing NRC Commitment Changes as endorsed by NRC Regulatory Issue Summary 2000-17, Managing Regulatory Commitments Made by Power Reactor Licensees to the NRC Staff.

The NRC staff reviewed your letters and agreed that they address a change of inspection scope that can be effected under the commitment management program you referenced.

Accordingly, there is no need for the NRC staff to issue any revision to its previous evaluation.

This closes all efforts covered by the above TAC number.

Sincerely,

/RA/

Peter S. Tam, Senior Project Manager, Section 1 Project Directorate I Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No. 50-220 cc: See next page DISTRIBUTION:

PUBLIC OGC PD1-1 R/F G. Hill (2)

R. Laufer P. Tam G. Hunegs S. Little ACRS J. Trapp, RI T. McLellan Accession Number: ML050740500 OFFICE PD1-1/PM PD1-1/LA EMCB EMCB/SC PDI-1/SC NAME PTam SLittle TMcLellan MMitchell PMilano for RLaufer DATE 3/29/05 3/24/05 3/29/05 3/28/05 3/29/05 OFFICIAL RECORD COPY

Nine Mile Point Nuclear Station, Unit No. 1 cc:

Mr. Michael J. Wallace President Nine Mile Point Nuclear Station, LLC c/o Constellation Energy Group 750 East Pratt Street Baltimore, MD 21202 Mr. Mike Heffley Senior Vice President and Chief Nuclear Officer Constellation Generation Group 1997 Annapolis Exchange Parkway Suite 500 Annapolis, MD 21401 Regional Administrator, Region I U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 Resident Inspector U.S. Nuclear Regulatory Commission P.O. Box 126 Lycoming, NY 13093 Charles Donaldson, Esquire Assistant Attorney General New York Department of Law 120 Broadway New York, NY 10271 Mr. Paul D. Eddy Electric Division NYS Department of Public Service Agency Building 3 Empire State Plaza Albany, NY 12223 Mr. Peter R. Smith, President New York State Energy, Research, and Development Authority 17 Columbia Circle Albany, NY 12203-6399 Mark J. Wetterhahn, Esquire Winston & Strawn 1400 L Street, NW Washington, DC 20005-3502 Supervisor Town of Scriba Route 8, Box 382 Oswego, NY 13126 Mr. Carey W. Fleming Senior Counsel - Nuclear Generation Constellation Energy Group, LLC.

750 East Pratt Street, 17th Floor Baltimore, MD 21202 Ms. Deb Katz, Executive Director Nuclear Security Coalition c/o Citizens Awareness Network P.O. Box 83 Shelburne Falls, MA 01370