Text
February 24, 2005 Mr. David A. Christian Senior Vice President and Chief Nuclear Officer Dominion Nuclear Connecticut, Inc.
5000 Dominion Boulevard Glen Allen, VA 23060-6711
SUBJECT:
SAFETY EVALUATION REPORT (SER) WITH OPEN ITEMS RELATED TO THE LICENSE RENEWAL OF MILLSTONE POWER STATION, UNITS 2 AND 3
Dear Mr. Christian:
By letter dated January 20, 2004, Dominion Nuclear Connecticut, Inc. (DNC or the applicant) submitted an application to the U.S. Nuclear Regulatory Commission (NRC) for the renewal of the Millstone Power Station, Units 2 and 3 (MPS), operating licenses for up to an additional 20 years. The license renewal applications (LRAs) were submitted pursuant to Title 10 of the Code of Federal Regulations Part 54, Requirements for Renewal of Operating Licenses for Nuclear Power Plants. The NRC staff determined that the LRA was complete and acceptable for docketing on March 12, 2004.
The NRC staff has reviewed the DNC, LRAs and has developed the enclosed Safety Evaluation Report With Open Items related to the License Renewal of the Millstone Power Station, Units 2 and 3, hereinafter referred to as the Safety Evaluation Report (SER). This SER reflects the status of the staffs review of the LRAs, requests for additional information (RAIs), the applicants responses to the NRC staffs RAIs and other questions related to the LRAs through February 15, 2005, unless otherwise noted. Issuance of the enclosed SER is an important milestone for both the applicant and the staff.
The NRC staff has identified open and confirmatory items in its review, that must be resolved before it can make a final determination on the application. The open items are summarized in Section 1.5 of the SER. Section 1.6 of the SER includes a list of confirmatory items with an explanation of the information required to satisfactorily resolve the issue. In order to resolve these items, the staff needs the additional information, as identified in the SER.
In accordance with the schedule for completing the review of the MPS LRAs, the applicant is requested to review the enclosed SER, verify its accuracy, and provide comments to the NRC staff by April 21, 2005. The NRC staff plans to review the current content and format of the SER for further improvement while incorporating the applicants comments. A complete and revised SER will then be issued by August 8, 2005.
D. Christian The staff is committed to completing the review of the MPS SER in a timely manner. If you have any questions regarding this matter, please contact the license renewal project manager, Johnny H. Eads, at 301-415-1471 or e-mail JHE@nrc.gov.
Sincerely,
/RA/
Pao-Tsin Kuo, Program Director License Renewal and Environmental Impacts Program Division of Regulatory Improvement Programs Office of Nuclear Reactor Regulation Docket Nos. 50-336 and 50-423
Enclosure:
As stated cc w/encls: See next page
ML050600172 Document Name: E:\\Filenet\\ML050600172.wpd
- Concurrence by e-mail
- Previously Concurred OFFICE PM:DRIP/RLEP/A LA:DRIP/RLEP OGC BC:DE/EMCB BC:DE/EMEB NAME JEads B. Poole W. Bateman*
G. Imbro*
DATE 02 / 04 /2005
/ /
02 / 23 /2005 02 / 17 /2005 02 / 17 /2005 OFFICE BC:DE/EEIB BC:DSSA/SPSB BC:DSSA/SRXB BC:DSSA/SPLB BC:DIPM/IEPB NAME J. Calvo*
R. Dennig*
F.Akstulewicz*
S. Jones*
T. Quay*
DATE 02 / 11 /2005 02 / 11 /2005 02 / 16 /2005 02 / 18 /2005 02 / 09 /2005 OFFICE D:DE D:DSSA D:DIPM D:DRIP SC:DRIP/RLEP/A NAME C. Grimes**
M. Johnson**
M. Case**
F. Gillespie SLee DATE 02 / 22 /2005 02 / 22 /2005 02 / 22 /2005 02/ 24 /2005 02/ 24 /2005 OFFICE PD:DRIP:RLEP NAME PTKuo DATE 02 / 24 /2005
Millstone Power Station, Units 2 and 3 cc:
Lillian M. Cuoco, Esquire Senior Counsel Dominion Resources Services, Inc.
Rope Ferry Road Waterford, CT 06385 Edward L. Wilds, Jr., Ph.D.
Director, Division of Radiation Department of Environmental Protection 79 Elm Street Hartford, CT 06106-5127 Regional Administrator, Region I U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 Paul Eccard First Selectman Town of Waterford 15 Rope Ferry Road Waterford, CT 06385 Mr. P. J. Parulis Manager - Nuclear Oversight Dominion Nuclear Connecticut, Inc.
Rope Ferry Road Waterford, CT 06385 Mr. W. R. Matthews Senior Vice President - Nuclear Operations Dominion Nuclear Connecticut, Inc.
Rope Ferry Road Waterford, CT 06385 Mr. John Markowicz Co-Chair Nuclear Energy Advisory Council 9 Susan Terrace Waterford, CT 06385 Mr. Evan W. Woollacott Co-Chair Nuclear Energy Advisory Council 128 Terry's Plain Road Simsbury, CT 06070 Senior Resident Inspector Millstone Power Station c/o U.S. Nuclear Regulatory Commission P. O. Box 513 Niantic, CT 06357 Mr. G. D. Hicks Director - Nuclear Station Safety and Licensing Dominion Nuclear Connecticut, Inc.
Rope Ferry Road Waterford, CT 06385 Ms. Nancy Burton 147 Cross Highway Redding Ridge, CT 00870 Mr. William D. Meinert Nuclear Engineer Massachusetts Municipal Wholesale Electric Company Moody Street P.O. Box 426 Ludlow, MA 01056 Mr. J. Alan Price Site Vice President Dominion Nuclear Connecticut, Inc.
Rope Ferry Road Waterford, CT 06385 Mr. Chris L. Funderburk Director, Nuclear Licensing and Operations Support Dominion Resources Services, Inc.
Innsbrook Technical Center 5000 Dominion Boulevard Glen Allen, VA 23060-6711 Mr. David W. Dodson Licensing Supervisor Dominion Nuclear Connecticut, Inc.
Rope Ferry Road Waterford, CT 06385
Millstone Power Station, Units 2 and 3 cc:
David R. Lewis Shaw Pittman, LLC 2300 N. Street N.W.
Washington, DC 20037 Mr. S. E. Scace Assistant to the Site Vice President Dominion Nucler Connecticut, Inc.
Rope Ferry Road Waterford, CT 06385 Mr. M. J. Wilson Manager - Nuclear Training Dominion Nuclear Connecticut, Inc.
Rope Ferry Road Waterford, CT 06385 Mr. A. J. Jordan, Jr.
Director - Nuclear Engineering Dominion Nuclear Connecticut, Inc.
Rope Ferry Road Waterford, CT 06385 Mr. S. P. Sarver Director - Nuclear Station Operations and Maintenance Dominion Nuclear Connecticut, Inc.
Rope Ferry Road Waterford, CT 06385 Mr. Charles Brinkman, Director Washington Operations Nuclear Services Westinghouse Electric Company 12300 Twinbrook Pkwy, Suite 330 Rockville, MD 20852 Mr. William D. Corbin Director - Nuclear Projects Department Innsbrook Technical Center 5000 Dominion Boulevard Glen Allen, VA 23060-6711 Mr. William R. Watson, Jr.
Supervisor - License Renewal Project Building 475/5 Millstone Power Station Rope Ferry Road Waterford, CT 06385 Judy Liskov, Assistant Director Waterford Public Library 49 Rope Ferry Road Waterford, CT 06385-2806 Mildred Hodge, Director Three Rivers Community College Thames River Campus 574 New London Turnpike Norwich, CT 06360 Ralph Bunge NRC Proceedings Representative for Waterford, CT 510 Carr Ave Rockville, MD 20850 Thomas V. Wagner, AICP Planning Director Town of Waterford 15 Rope Ferry Road Waterford, CT 06385 Robert A. Avena Town Attorney for Waterford, CT Kepple, Morgan & Avena, P.C.
Box 3A Anguilla Park 20 South Anguilla Road Pawcatuck, CT 06379 Mr. Fred Emerson Nuclear Energy Institute 1776 I Street NW, Suite 400 Washington, DC 20006-3708
DISTRIBUTION: Transmittal Letter to: D. Christian, Re: Safety Evaluation Report w/ open items related to the License Renewal of Millstone, Dated: February 24, 2005 Adams Accession No.: ML050600172 HARD COPY RLEP RF E-MAIL:
RidsNrrDrip RidsNrrDe G. Bagchi K. Manoly W. Bateman J. Calvo R. Jenkins P. Shemanski J. Fair RidsNrrDssa RidsNrrDipm D. Thatcher R. Pettis G. Galletti C. Li K. Winsberg (RidsOgcMailCenter)
R. Weisman M. Mayfield A. Murphy S. Smith (srs3)
S. Duraiswamy Y. L. (Renee) Li RLEP Staff C. Holden R. Laufer P. Tam B. Fuller, RI E. Knutson, RI J. Trapp, RI T. Mensah Receptionist OPA PMNS