Tech Spec Page for Amendment 210 Revision to TS 2.1.1.2 for Dual Recirculation Loop and Single Recirculation Loop Safety Limit Minimum Critical Power Ratio
ML050490344
Person / Time
Site: Cooper Entergy icon.png
Issue date: 02/01/2005
From:
NRC/NRR/DLPM
To:
Honcharik M, NRR/DLPM, 301-415-1774
References
TAC MC4953
Download: ML050490344 (1)


Text

SLs 2.0 2.0 SAFETY LIMITS (SLs) 2.1 SLs 2.1.1 Reactor Core SLs 2.1.1.1 With the reactor steam dome pressure < 785 psig or core flow < 10%

rated core flow:

THERMAL POWER shall be < 25% RTP.

2.1.1.2 With the reactor steam dome pressure > 785 psig and core flow

> 10% rated core flow:

MCPR shall be> 1.12 for two recirculation loop operation or> 1.13 for I single recirculation loop operation.

2.1.1.3 Reactor vessel water level shall be greater than the top of active irradiated fuel.

2.1.2 Reactor Coolant System Pressure SL Reactor steam dome pressure shall be < 1337 psig.

2.2 SL Violations With any SL violation, the following actions shall be completed within 2 hour2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />s:

2.2.1 Restore compliance with all SLs; and 2.2.2 Insert all insertable control rods.

Amendment 210 2.0-1