ML050210381

From kanterella
Jump to navigation Jump to search
E-mail to: Peter Mazzaferro at Constellation from: Ngoc Le, Subject: Followup Questions-01-11-05 References Your Responses to NRC Rais, NM1L 1900 Dated 12/17/04
ML050210381
Person / Time
Site: Nine Mile Point  
Issue date: 01/11/2005
From: Le N
NRC/NRR/DRIP/RLEP
To: Mazzaferro P
Constellation Energy Group, Niagara Mohawk Power Corp
Le N. B., NRR/DRIP/RLEP, 415-1458
References
Download: ML050210381 (1)


Text

From:

Ngoc Le To:

Peter.Mazzaferro@Constellation.com Date:

1/11/05 5:30PM

Subject:

Followup questions 11-05 Pete:

Reference:

Your Responses to NRC RAIs, NMPIL 1900 dated 12/17/04 The staff has followup questions regarding your responses to the steam separator (RAI-4) and feedwater spargers (RAI-5) of the referenced document. The concern is whether these components can fail and cause nearby, safety-related components to fail. If so, then they should be in scope.

Please check the availability of your tech staff and we can set up a conference call to address the concern with the NRC reviewer.

Proposed time: Wednesday PM, Thursday, and Friday and this week.

Please let me know.

tommy le CC:

Samuel Miranda