January 14, 2005 Mr. G. R. Peterson Vice President McGuire Nuclear Station Duke Energy Corporation 12700 Hagers Ferry Road Huntersville, NC 28078-8985
SUBJECT:
MCGUIRE NUCLEAR STATION, UNITS 1 AND 2 - REQUEST FOR ADDITIONAL INFORMATION RE: RELIEF REQUEST 04-MN-02, 04-MN-03 AND 04-MN-04, ALTERNATIVES TO AMSE SECTION XI (TAC NOS. MC4514, MC4515, AND MC4516)
Dear Mr. Peterson:
By letter to the Nuclear Regulatory Commission (NRC) dated August 9, 2004, pursuant to Title 10 of the Code of Federal Regulations, Section 50.55a(a)(3), you requested the use of an alternative to the American Society of Mechanical Engineers Boiler and Pressure Vessel Code,Section XI, for McGuire Nuclear Station, Units 1 and 2. The NRC staff has reviewed your submittal and has determined that additional information is required. Our questions are provided in the Enclosure. We discussed this question with your staff on January 10, 2005.
Your staff indicated that a response could be provided within 45 days of the date of this letter.
If you have any further questions on this matter, please call me at (301) 415-1388.
Sincerely,
/RA/
James J. Shea, Project Manager, Section 1 Project Directorate II Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket Nos. 50-369 and 50-370
Enclosure:
Request for Additional Information cc w/encl: See next page
ML050140002 NRR-088 OFFICE PDII-1/PM PDII-1/LA DE/EMCB/SC PDII-1/SC NAME JShea CHawes TChan JNakoski DATE 1/13/05 1/14/05 1/13/05 1/14/05
REQUEST FOR ADDITIONAL INFORMATION RELIEF REQUEST 04-MN-02, 04-MN-03 AND 04-MN-04, ALTERNATIVES TO AMSE SECTION XI DUKE ENERGY CORPORATION MCGUIRE NUCLEAR STATION, UNITS 1 AND 2 DOCKET NOS. 50-369 AND 50-370
- 1.
Regarding 1RPVI-462C-SE, since this is an item identified in the Risk Informed In-service Inspection program, have other welds of the same material, similar environment, and similar risk category been considered as a substitute so that a 100 percent volumetric coverage can be achieved. In addition, was a surface examination performed on 1RPVI-462C-SE? What was the coverage achieved?
What were the results from previous inspections?
- 2.
For component 2N12FW26-15 (Item C05.011.168) the Code requires both volumetric and surface examinations. The submittal implied that surface examinations have been completed. What was the coverage achieved?
3.
For all other components for which 100 percent volumetric can not be achieved (e.g.,
2NCW-3673-1, 2NC2FW22-6), please state if surface examination has been performed, and the coverage achieved. Similarly, for components for which 100 percent surface can not be achieved (e.g. 1CCPUMP-1A), although not required by the Code, please state if volumetric examination has been considered as an alternative to supplement the coverage of surface examination.
McGuire Nuclear Station cc:
Ms. Lisa F. Vaughn Duke Energy Corporation Mail Code - PB06E 422 South Church Street P.O. Box 1244 Charlotte, North Carolina 28201-1244 County Manager of Mecklenburg County 720 East Fourth Street Charlotte, North Carolina 28202 Mr. C. Jeffrey Thomas Regulatory Compliance Manager Duke Energy Corporation McGuire Nuclear Site 12700 Hagers Ferry Road Huntersville, North Carolina 28078 Ms. Anne Cottingham, Esquire Winston and Strawn 1400 L Street, NW Washington, DC 20005 Senior Resident Inspector c/o U.S. Nuclear Regulatory Commission 12700 Hagers Ferry Road Huntersville, North Carolina 28078 Dr. John M. Barry Mecklenburg County Department of Environmental Protection 700 N. Tryon Street Charlotte, North Carolina 28202 Mr. Peter R. Harden, IV VP-Customer Relations and Sales Westinghouse Electric Company 6000 Fairview Road, 12th Floor Charlotte, North Carolina 28210 Ms. Karen E. Long Assistant Attorney General North Carolina Department of Justice P.O. Box 629 Raleigh, North Carolina 27602 Mr. R. L. Gill, Jr.
Manager - Nuclear Regulatory Issues and Industry Affairs Duke Energy Corporation 526 South Church Street Mail Stop EC05P Charlotte, North Carolina 28202 NCEM REP Program Manager 4713 Mail Service Center Raleigh, North Carolina 27699-4713 Mr. Richard M. Fry, Director Division of Radiation Protection North Carolina Dept. of Environment, Health and Natural Resources 3825 Barrett Drive Raleigh, North Carolina 27609-7721 Mr. T. Richard Puryear Owners Group (NCEMC)
Duke Energy Corporation 4800 Concord Road York, South Carolina 29745 Mr. Henry Barron Group Vice President, Nuclear Generation and Chief Nuclear Officer P.O. Box 1006-EC07H Charlotte, North Carolina 28201-1006