Technical Specifications, Revise TS Surveillance Requirement 3.3.2.1.4 and Table 3.3.2.1-1 to Correct Mathematical Symbols & Use Allowable Values in Place of Analytical Limits
ML043630383
Person / Time
Site: Cooper 
(DPR-046)
Issue date: 12/22/2004
From: Michelle Honcharik
NRC/NRR/DLPM/LPD4
To: Edington R
Nebraska Public Power District (NPPD)
Honcharik M, NRR/DLPM, 301-415-1774
Shared Package
ML050040269 List:
References
TAC MC0629
Download: ML043630383 (2)


Text

Control Rod Block Instrumentation 3.3.2.1 SURVEILLANCE REQUIREMENTS (continued)

SURVEILLANCE FREQUENCY SR 3.3.2.1.2


NOTE-----------------------------

Not required to be performed until 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> after any control rod is withdrawn at < 10% RTP in MODE 2.

Perform CHANNEL FUNCTIONAL TEST.

92 days SR 3.3.2.1.3


NOTE-----------------------------

Not required to be performed until 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> after THERMAL POWER is < 10% RTP in MODE 1.

Perform CHANNEL FUNCTIONAL TEST.

92 days SR 3.3.2.1.4


NOTE-----------------------------

Neutron detectors are excluded.

Verify the RBM:

184 days

a.

Low Power Range -

Upscale Function is not bypassed when THERMAL POWER is

> 27.5% and < 62.5% RTP and a peripheral control rod is not selected.

b.

Intermediate Power Range -

Upscale Function is not bypassed when THERMAL POWER is > 62.5% and < 82.5% RTP and a peripheral control rod is not selected.

c.

High Power Range -

Upscale Function is not bypassed when THERMAL POWER is

> 82.5% RTP and a peripheral control rod is not selected.

(continued)

I I

I Cooper 3.3-1 7 Amendment No.. 208

Control Rod Block Instrumentation 3.3.2.1 Table 3.3.2.1-1 (page 1 of 1)

Control Rod Block Instrumentation APPLICABLE MODES OR OTHER SPECIFIED REQUIRED SURVEILLANCE ALLOWABLE FUNCTION CONDITIONS CHANNELS REQUIREMENTS VALUE

1. Rod Block Monitor
a.

Low Power Range -

Upscale (a) 2 SR 3.3.2.1.1 (h)

SR 3.3.2.1.4 SR 3.3.2.1.5

b.

Intermediate Power Range -

Upscale (b) 2 SR 3.3.2.1.1 (h)

SR 3.3.2.1.4 SR 3.3.2.1.5

c.

High Power Range -

Upscale (c),(d) 2 SR 3.3.2.1.1 (h)

SR 3.3.2.1.4 SR 3.3.2.1.5

d.

Inop (d),(e) 2 SR 3.3.2.1.1 NA

e.

Downscale (d),(e) 2 SR 3.3.2.1.1

>92/125 SR 3.3.2.1.5 divisions of full scale

2.

Rod Worth Minimizer 1(f),2(f) 1 SR 3.3.2.1.2 NA SR 3.3.2.1.3 SR 3.3.2.1.6 SR 3.3.2.1.8

3.

Reactor Mode Switch -

Shutdown Position (g) 2 SR 3.3.2.1.7 NA (a)

THERMAL POWER > 27.5% and < 62.5% RTP and MCPR < 1.70 and no peripheral control rod selected.

(b)

THERMAL POWER > 62.5% and < 82.5% RTP and MCPR < 1.70 and no peripheral control rod selected.

(c)

THERMAL POWER > 82.5% and < 90% RTP and MCPR < 1.70 and no peripheral control rod selected.

(d)

THERMAL POWER > 90% RTP and MCPR < 1.40 and no peripheral control rod selected.

(e)

THERMAL POWER > 27.5% and < 90% RTP and MCPR < 1.70 and no peripheral control rod selected.

(0)

With THERMAL POWER < 10% RTP.

(g)

Reactor mode switch in the shutdown position.

(h)

Less than or equal to the Allowable Value specified in the COLR.

I.

I Cooper 3.3-1 9 Amendment No.208