Indiana Michigan Power Company 500 Circle Drive Buchanan, MI 49107 1395 INDIANA MICHIGAN POWER December 15, 2004 AEP:NRC:269 1-49 Docket Nos.

50-315 50-316 U. S. Nuclear Regulatory Commission Attn: Document Control Desk Mail Stop O-P1-17 Washington, DC 20555-0001 Donald C. Cook Nuclear Plant Units 1 and 2 MONTHLY OPERATING REPORT Pursuant to the requirements of Donald C. Cook Nuclear Plant Unit 1 and Unit 2 Technical Specification 6.9.1.8, the attached Monthly Operating Report for November 2004 is submitted.

There are no new commitments associated with this submittal.

Should you have any questions, please contact Mr. Toby K. Woods, Compliance Supervisor, at (269) 466-2798.

Sincerely, in'eph N. Jensen Site Vice President JEN/jen Attachment I/

U. S. Nuclear Regulatory Commission AEP:NRC:2691-49 Page 2 c: R. Aben - Department of Labor and Economic Growth ANI Nuclear Engineering Department L. Brandon - MDEQ - WHMD/HWRPS D. P. Fadel M. J. Finissi G. T. Gaffney - Canton R. A. F. Harris INPO Records Center J. N. Jensen J. T. King - MPSC B. Lewis - McGraw-Hill Companies D. H. Malin K. L. Matheny M. K. Nazar NRC Project Manager - NRR NRC Region III NRC Resident Inspector D. W. Paul - Columbus W. H. Schalk J. A. Zwolinski

N.R.C. OPERATING DATA REPORT DOCKET NO.

50-315 DATE 12/8/2004 COMPLETED BY R. Harris TELEPHONE 269-465-5901 OPERATING STATUS

1. Unit Name D. C. Cook Unit 1 Notes:
2. Reporting Period Nov-04
3. Licensed Thermal Power (MWt) 3304
4. Name Plate Rating (Gross MWe) 1152
5. Design Electrical Rating (Net MWe) 1020
6. Maximum Dependable Capacity(GROSS MWe) 1056
7. Maximum Dependable Capacity (Net MWe) 1000
8. If Changes Occur in Capacity Ratings (Items no. 3 through 7) Since Last Report Give Reasons
9. Power Level To Which Restricted. If Any (Net MWe)
10. Reasons For Restrictions.

This Mo.

Yr. to Date Cumm.

11. Hours in Reporting Period 720.0 8040.0 262248.0
12. No. of Hrs. Reactor Was Critical 720.0 7855.9 181757.2
13. Reactor Reserve Shutdown Hours 0.0 0.0 463.0
14. Hours Generator on Line 720.0 7844.9 179024.5
15. Unit Reserve Shutdown Hours 0.0 0.0 321.0
16. Gross Therm. Energy Gen. (MWH) 2376620.1 25844368.5 537212896.0
17. Gross Elect. Energy Gen. (MWH) 770950.0 8335140.0 174376943.0
18. Net Elect. Energy Gen. (MWH) 745386.0 8057948.8 167903232.7
19. Unit Service Factor 100.0 97.6 68.7
20. Unit Availability Factor 100.0 97.6 68.7
21. Unit Capacity Factor (MDC Net) 103.5 100.2 65.4
22. Unit Capacity Factor (DER Net) 101.5 98.3 64.1
23. Unit Forced Outage Rate 0.0 0.0 18.4
24. Shutdowns Scheduled over Next Six Months (Type,Date,and Duration):

Refueling outage currently scheduled for April 2005 with a planned duration of approximately 35 days

25. If Shut Down At End of Report Period, Est'd Date of Startup:
26. Units in Test Status (Prior to Commercial Operation):

Forecast Achieved INITIAL CRITICALITY INITIAL ELECTRICITY COMMERCIAL OPERATION

AVERAGE DAILY POWER LEVEL (MWe-Net)

DOCKET NO.

UNIT DATE COMPLETED BY TELEPHONE 50-315 ONE 08-Dec-04 R. Harris 269-465-5901 MONTH Nov-04 AVERAGE DAILY POWER LEVEL AVERAGE DAILY POWER LEVEL DAY DAY 11/1/2004 11/2/2004 11/3/2004 11/4/2004 11/5/2004 11/6/2004 11/7/2004 11/8/2004 11/9/2004 11/10/2004 11/11/2004 11/12/2004 11/13/2004 11/14/2004 11/15/2004 11/16/2004 1036 1032 1039 1035 1039 1040 1031 1028 1028 1039 1035 1030 1034 1038 1034 1038 11/17/2004 11/18/2004 11/19/2004 11/20/2004 11/21/2004 11/22/2004 11/23/2004 11/24/2004 11/25/2004 11/26/2004 11/27/2004 11/28/2004 11/29/2004 11/30/2004 1039 1045 1030 1043 1034 1036 1033 1052 1015 1037 1036 1034 1034 1034

DOCKET NO.

UNIT NAME DATE COMPLETED BY TELEPHONE PAGE 50 - 315 D.C. Cook Unit 1 December 8, 2004 J. Newmiller 269-465-5901 1 of 1 UNIT SHUTDOWNS AND POWER REDUCTIONS - November 2004 METHOD OF SHUTTING LICENSEE DURATION DOWN EVENT SYSTEM COMPONENT CAUSE AND CORRECTIVE ACTION NO.

DATE TYPE' HOURS REASON 2 REACTOR3 REPORT NO.

CODE4 CODE5 TO PREVENT RECURRENCE None 1 TYPE:

F: Forced S: Scheduled 2 REASON:

A: Equipment Failure (Explain)

B: Maintenance or Test C: Refueling D: Regulatory Restriction E: Operator Training and License Examination F: Administrative G: Operational Error (Explain)

H: Other (Explain) 3 METHOD:

1: Manual 2: Manual Scram 3: Automatic Scram 4: Other (Explain) 4 SYSTEM:

Exhibit G - Instructions for preparation of data entry sheets for Ucensee Event Report (LER) File (NUREG 0161) 5 COMPONENT:

Exhibit I: Same Source

N.R.C. OPERATING DATA REPORT DOCKET NO.

50-316 DATE 12/812004 COMPLETED BY R. Harris TELEPHONE 269-465-5901 OPERATING STATUS

1. Unit Name D. C. Cook Unit 2 Notes:
2. Reporting Period Nov-04
3. Licensed Thermal Power (MWt) 3468
4. Name Plate Rating (Gross MWe) 1133
5. Design Electrical Rating (Net MWe) 1090
6. Maximum Dependable Capacity(GROSS MWe) 1100
7. Maximum Dependable Capacity (Net MWe) 1060
8. If Changes Occur in Capacity Ratings (Items no. 3 through 7) Since Last Report Give Reasons
9. Power Level To Which Restricted. If Any (Net MWe)
10. Reasons For Restrictions.

This Mo.

Yr. to Date Cumm.

11. Hours in Reporting Period 720.0 8040.0 236394.0
12. No. of Hrs. Reactor Was Critical 377.9 6721.9 155005.2
13. Reactor Reserve Shutdown Hours 0.0 0.0 0.0
14. Hours Generator on Line 353.9 6664.1 151018.3
15. Unit Reserve Shutdown Hours 0.0 0.0 0.0
16. Gross Therm. Energy Gen. (MWH) 1019020.5 22632450.9 476308310.5
17. Gross Elect. Energy Gen. (MWH) 328300.0 7339418.0 154453448.0
18. Net Elect. Energy Gen. (MWH) 316547.4 7102477.9 148967384.6
19. Unit Service Factor 49.2 82.9 64.5
20. Unit Availability Factor 49.2 82.9 64.5
21. Unit Capacity Factor (MDC Net) 41.5 83.3 60.6
22. Unit Capacity Factor (DER Net) 40.3 81.0 58.9
23. Unit Forced Outage Rate 0.0 4.2 22.7
24. Shutdowns Scheduled over Next Six Months (Type,Date,and Duration):
25. If Shut Down At End of Report Period, Est'd Date of Startup:
26. Units in Test Status (Prior to Commercial Operation):

Forecast Achieved INITIAL CRITICALITY INITIAL ELECTRICITY COMMERCIAL OPERATION

A f

r w

AVERAGE DAILY POWER LEVEL (MWe-Net)

DOCKET NO.

UNIT DATE COMPLETED BY TELEPHONE 50-316 TWO 8-Dec-04 R. Harris 269-465-5901 MONTH Nov-04 AVERAGE DAILY POWER LEVEL AVERAGE DAILY POWER LEVEL DAY 11/1/2004 11/212004 11/3/2004 11/4/2004 11/5/2004 11/6/2004 11/7/2004 11/8/2004 11/9/2004 11/10/2004 11/11/2004 11/12/2004 11/13/2004 11/14/2004 11/15/2004 11/16/2004 DAY 0

0 0

0 0

0 0

0 0

198 318 581 1037 1060 1105 1123 11/17/2004 11/18/2004 11/19/2004 11/20/2004 11/21/2004 11/22/2004 11/23/2004 11/24/2004 11/25/2004 11/26/2004 11/27/2004 11/28/2004 11/29/2004 11/30/2004 1122 1091 1116 1112 1111 769 0

0 0

0 0

0 341 1105

DOCKET NO.

UNIT NAME DATE COMPLETED BY TELEPHONE PAGE 50 - 316 W

D.C. Cook Unit 2 December 8, 2004 J. Newmiller 269-465-5901 1 of 1 UNIT SHUTDOWNS AND POWER REDUCTIONS - November 2004 METHOD OF SHUTTING LICENSEE DURATION DOWN EVENT SYSTEM COMPONENT CAUSE AND CORRECTIVE ACTION NO.

DATE TYPE' HOURS REASON2 REACTOR 3 REPORT NO.

CODE4 CODE5 TO PREVENT RECURRENCE 219 041001 S

214.5 C

2 N/A N/A N/A Scheduled refueling outage 220 041110 S

1.1 H

N/A N/A TA TRB Generator taken off line for main turbine overspeed testing.

221 041122 S

150.5 A

1 N/A AB PZR RCS leak due to faulty pressurizer manway gasket.

1 TYPE:

F: Forced S: Scheduled 2 REASON:

A: Equipment Failure (Explain)

B: Maintenance or Test C: Refueling D: Regulatory Restriction E: Operator Training and License Examination F: Administrative G: Operational Error (Explain)

H: Other (Explain) 3 METHOD:

1: Manual 2: Manual Scram 3: Automatic Scram 4: Other (Explain) 4 SYSTEM:

Exhibit G - Instructions for preparation of data entry sheets for Licensee Event Report (LER) File (NUREG 0161) 5 COMPONENT:

Exhibit 1: Same Source