December 15, 2004 Dr. Terrence Tehan, Director Rhode Island Nuclear Science Center Rhode Island Atomic Energy Commission 16 Reactor Road Narragansett, RI 02882-1165
SUBJECT:
RHODE ISLAND NUCLEAR SCIENCE CENTER (RINSC) REQUEST FOR ADDITIONAL INFORMATION RE: REQUEST FOR AMENDMENT NO. 30 TO FACILITY OPERATING LICENSE NO. R-95 (TAC NOS. MC1459, MC2878 and MC2879 )
Dear Dr. Tehan:
We are continuing our review of your request for Amendment to Facility Operating License No. R-95 for the RINSC Research Reactor submitted in RINSCs letters dated November 20, 2003, March 5, 2004, April 5, 2004, August 16, 2004, October 26, 2004, and November 15, 2004. Several of the changes will be issued separately as Amendment No. 29 as per your request in the August 16, 2004 letter. The remaining proposed Technical Specification (TS) changes are still under review. Questions have arisen for which we require additional information and clarification. Please provide responses to the enclosed request for additional information within 60 days of the date of this letter. In accordance with 10 CFR 50.30 (b), your response must be executed in a signed original under oath or affirmation. Following receipt of the additional information, we will continue our evaluation of your license amendment request.
If you have any questions regarding this review, please contact me at 301-415-1631.
Sincerely,
/RA/
Daniel E. Hughes, Project Manager Research and Test Reactors Section New, Research and Test Reactors Program Division of Regulatory Improvement Programs Office of Nuclear Reactor Regulation Docket No. 50-193
Enclosure:
As stated cc w/enclosure: Please see next page
Rhode Island Nuclear Science Center Docket No. 50-193 cc:
Dr. Vincent C. Rose, Chairman, RIAEC University of Rhode Island Chemical Engineering Department 118 Crawford Hall Kingston, RI 02881 Dr. Harry Knickle, Chairman Nuclear and Radiation Safety Committee University of Rhode Island College of Engineering 102 Bliss Hall Kingston, RI 02881 Mr. Charles McMahon Supervisor, Radiation Control Specialist Rhode Island Department of Health Division of Occupational and Radiological Health 3 Capitol Hill Cannon Providence, RI 02808-5097 Test, Research, and Training Reactor Newsletter University of Florida 202 Nuclear Sciences Center Gainesville, FL 32611
December 15, 2004 Dr. Terrence Tehan, Director Rhode Island Nuclear Science Center Rhode Island Atomic Energy Commission 16 Reactor Road Narragansett, RI 02882-1165
SUBJECT:
RHODE ISLAND NUCLEAR SCIENCE CENTER (RINSC) REQUEST FOR ADDITIONAL INFORMATION RE: REQUEST FOR AMENDMENT NO. 30 TO FACILITY OPERATING LICENSE NO. R-95 (TAC NOS. MC1459, MC2878 and MC2879 )
Dear Dr. Tehan:
We are continuing our review of your request for Amendment to Facility Operating License No. R-95 for the RINSC Research Reactor submitted in RINSCs letters dated November 20, 2003, March 5, 2004, April 5, 2004, August 16, 2004, October 26, 2004, and November 15, 2004. Several of the changes will be issued separately as Amendment No. 29 as per your request in the August 16, 2004 letter. The remaining proposed Technical Specification (TS) changes are still under review. Questions have arisen for which we require additional information and clarification. Please provide responses to the enclosed request for additional information within 60 days of the date of this letter. In accordance with 10 CFR 50.30 (b), your response must be executed in a signed original under oath or affirmation. Following receipt of the additional information, we will continue our evaluation of your license amendment request.
If you have any questions regarding this review, please contact me at 301-415-1631.
Sincerely,
/RA/
Daniel E. Hughes, Project Manager Research and Test Reactors Section New, Research and Test Reactors Program Division of Regulatory Improvement Programs Office of Nuclear Reactor Regulation Docket No. 50-193
Enclosure:
As stated cc w/enclosure: Please see next page DISTRIBUTION:
PUBLIC RNRP/R&TR r/f TDragoun MMendonca AAdams WBeckner OGC EHylton FGillespie CBassett DMatthews WEresian SHolmes Isaac GHill (2)
PDoyle DHughes PMadden KWitt PYoung ADAMS ACCESSION NO.: ML043480220 TEMPLATE No.: NRR-106 OFFICE RNRP:PM RNRP:LA RNRP:SC NAME DHughes EHylton PMadden DATE 12/ 13 /04 12/ 14 /04 12/ 14 /04 C = COVER E = COVER & ENCLOSURE N = NO COPY OFFICIAL RECORD COPY
REQUEST FOR ADDITIONAL INFORMATION RHODE ISLAND NUCLEAR SCIENCE CENTER DOCKET NO. 50-193 No.
TS Page TS Section/Table/
Figure Request or Question 1
42 6.1.2 (November 20, 2003 Ltr)
Please provide further discussion concerning the requested change to this TS. Include in the discussion how the intent of section 6.1.3 of ANSI/ANS-15.1-1990, The Development of Technical Specifications for Research Reactors, is satisfied if the proposed change is accepted. Please justify not prohibiting the actions that are now prohibited, when combined with TS 1.9.1c, by your present TS 6.1.2. Please describe the
...routine pre-checks of systems and experiments at pool level... and why the master switch must be on and only the reactor operator can do the pre-checks. Discuss how, while the key is in the console and the master switch is not in the off position and no one is in the control room, the proposed change limits the actions of the reactor operator or monitors the consequences of the actions of the operator or other personnel. Discuss how it is assured that no reactor operations are performed that do not meet the requirements of 10 CFR 50.54 (i-m).
2 19 Proposed Table 3.2 (November 20, 2003 Ltr)
Please discuss number 5, Ln Period, of this proposed table.
This instrumentation is not part of the existing TS, is not marked as a change on the proposed replacement page, and there is no discussion of the change in the amendment request letter dated November 20, 2003.
3 19 Table 3.2 (November 20, 2003 Ltr)
Discuss the note that is proposed for Table 3.2 Grab sampling may be substituted for monitoring operations for up to eight hours in the event of monitor failure. What method will be used to evaluate the sample? What sample frequency shall be used? What alarm level will be appropriate?
4 15 Proposed Section 3.2.5 (November 20, 2003 Ltr)
Please discuss the setpoint and function of the two radiation monitors proposed. Please discuss how these two monitors are able to provide equivalent function and coverage of the monitors that are now specified in Table 3.2. 6-11.
5 42 Proposed Section 6.0.1 (April 5, 2004 Ltr)
Please discuss the purpose of the reduction in the number of voting members in the NRSC.
6 47 Section 6.4.4 (April 5, 2004 Ltr)
Please justify maintaining this section unchanged while proposing that the voting membership be reduced to four members. The intent of the existing specification and Section 6.2.2 (2) of ANSI/ANS-15.1-1990, The Development of Technical Specifications for Research Reactors, is that the quorum be a majority of the voting membership. With the proposed change it is possible that a valid quorum could include only one voting member, the Chairman or designee.