Job Performance Measure Exam 27-Sep-2004 JPM NO JC076.007 Perform ATTACHMENT NO SW PUMPS Revision #:

0 Review Date:

Location:

Simulator Estimated Time (minutes):

Candidate:

10.00 Evaluator:

Actual Time:

>L Trainee Performance:

Satisfactory Unsatisfactory Trainee:

Instructor:

Submitted By Date Reviewed By Date

Page:

2 Job Performance Measure Exam 27-Sep-2004 NOTE THE EVALUATOR WILL EXPLAIN THE JPM INITIAL CONDITIONS AND PROVIDE CLARIFICATION AS REQUIRED. THE EXAMINEE MAY USE ANY CONTROLLED COPY REFERENCES THAT ARE NORMALLY AVAILABLE IN THE CONTROL ROOM, INCLUDING LOGS. MAKE ALL WRITTEN REPORTS, ORAL REPORTS, AND LOG ENTRIES AS IF THE EVOLUTION WAS ACTUALLY BEING PERFORMED. THE EVALUATOR WILL BE TAKING NOTES. ASK FOR CLARIFICATION OF JPM REQUIREMENTS PRIOR TO THE BEGINNING Initia 1 Conditions:

Option 1: The plant was at 100% power when all SW pumps tripped and could not be restarted.

The crew tripped the Reactor. The E-0 immediate actions have been performed. The crew has just entered ES-0.1, "REACTOR TRIP RESPONSE."

The plant was at 100% power when Alarm L-12, "Condenser Pit or Screenhouse High

=

was received followed by L-15 and L-23, "Bus 17/18 Undervoltage" and L-5, "Safeguard Bus Main Breaker Overcurrent Trip". The E-0 immediate actions have been performed. The crew has just entered ES-0.1, "REACTOR TRIP RESPONSE."

L.

Initiating Cues :

The CRF directs you to perform Att-2.4 "ATTACHMENT NO SW PUMPS" while the rest of the crew continues with ES-0.1 "REACTOR TRIP RESPONSE".

Page:

3 Job Performance Measure Exam 2 7-Sep-2004

-u

==

Description:==

Respond to a Total Loss of SW JPM Tasks Task ID: 076-004-05-01 Task Standards In accordance with the procedure Tools :

Installed indication Procedures Installed switches/pushbuttons Terminating Cues Task Completion References :

ID

\\.

PRATT ATT-2.4 Descrbtion ATTACHMENT NO SW PUMPS Safety Considerations Conseauences of Inadequate Performance:

Equipment Damage Thermal design limit challenge Procedure Violation General Comments :

Review Date Ref Flag 0

Simulator setup with Reactor tripped from 100% power, Option 1 - All service water pumps tripped,

& 18 de-energized and both DIGS running unloaded. (Malf CRC03A, 200,000; Malf L,

I--

~

I 4 1 Page:

Job Performance Measure Exam 2 7-Sep-2004 Performance Checklist 1

Element :

Cue Conditions :

CUE: Give examinee a copy of PUMPS.

ATT-2.4 ATTACHMENT NO SW Standards :

Comments :

Satisfactory Unsatisfactory 2

Element :

Conditions :

Note - Steps 1 through 5 should be performed promptly to avoid equipment damage.

Comments :

Satisfactory 0 Standards :

Ensure examinee reads note and performs steps in a prompt manner.

Unsatisfactory 0 Element :

CRITICAL Conditions :

Trip both RCPs.

Comments :

Satisfactory 0 Standards :

Locates control switches for RCPs and trips both RCPs Unsatisfactory 0

  • 4 Element:

CRITICAL Conditions :

Standards :

Determine if any D/G running without alternate cooling.

Option 1) No D/G running (Go to e

o t

h D/G running (Go to Same as Element.

Comments :

Satisfactory n Unsatisfactory

  • 5 Element:

CRITICAL Conditions :

Standards :

D/Gs can be shutdown in any order.

Pull stop the affected D/G.

Locates control switch for A D/G and takes switch to pull stop.

L Comments:

Satisfactory n Unsatisfactory

5 1 Page:

Job Performance Measure Exam 2 7-Sep-2004

  • 6 Element:

CRITICAL Conditions :

Immediately depress voltage shutdown pushbutton for A D/G Standards :

Locates voltage shutdown pushbutton for A D/G and immediately depresses pushbutton.

Comments :

Satisfactory n Unsatisfactory

  • 7 Element:

CRITICAL Conditions :

Pull stop the affected D/G.

Standards :

Locates control switch for B DIG and takes switch to pull stop.

Comments :

Satisfactory Unsatisfactory 0

  • 8 9

10 c

Element :

CRITICAL Conditions :

Immediately depress voltage shutdown pushbutton for B D/G

~

Standards :

Locates voltage shutdown pushbutton for B D/G and immediately depresses pushbutton.

Comments :

Satisfactory 0 Unsatisfactory 0 Element :

Conditions :

Directs an A 0 to align alternate cooling to both D/Gs using ER-D/G.2.

Comments :

Satisfactory Standards :

Contacts A 0 and directs A 0 to align alternate cooling to D/Gs per ER-D/G.2.

Unsatisfactory 0 Element :

Conditions :

Determine if Bus 17 has been potentially damaged.

Standards :

Based on initial conditions determines that Bus 17 has been possibly damaged, Directs A 0 to locally open breaker 1B3, B D/G Is01 Bkr to Bus 17 in B DIG room.

Page:

6 Job Performance Measure Exam 2 7-Sep-2004 Comments :

Satisfactory 0 Unsatisfactory 11 Element:

Conditions :

Close Letdown isolation, AOV-427 Comments :

Satisfactory Standards :

Locates control switch for AOV-427 and places control switch in close.

Unsatisfactory 0 12 Element:

Conditions :

Close excess letdown, HCV-123 Comments :

Satisfactory Standards :

Locates manual controller for HCV-123 and adjusts ( or verifies) controller has "0" demand and no pressure indicated on PI-12 1.

Unsatisfactory 0

  • 13 Element :

CRITICAL Conditions :

Close both MSIVs.

Standards :

Locates control switch for AOV-35 16) and closes both MSIVs.

MSIVS (AOV-35 17 &

CUE: The other operator will control temperature using ARV's.

Comments :

Satisfactory 0

Unsatisfactory 0

  • 14 Element :

CRITICAL Conditions :

Pull stop control switches for both MDAFW pumps.

Comments :

Satisfactory 0 Standards :

Locates control swithes for A and B AFW pumps and places both switches in pull stop.

Unsatisfactory 0

I I

7 1 Page:

Job Performance Measure Exam 2 7-Sep-2004 L

  • 15 Element:

CRITICAL Conditions :

Pull stop control switches for all four CNMT Recirc Fans.

Comments :

Satisfactory 0

Standards :

Locates control switches for all four CNMT Recirc Fans and places switches in pull stop.

Unsatisfactory 0 16 Element:

Conditions :

Pull stop control switches for both MFW pumps.

Comments :

Satisfactory Standards :

Locates control switches for both MFW pumps and places switches in pull stop.

Unsatisfactory 0 17 Element:

Conditions :

Pull stop control switches for Condensate Pumps.

Comments :

Satisfactory Standards :

Locates control switches for Condensate pumps and places all three switches in pull stop.

Unsatisfactory 0 18 Element:

Conditions :

Standards :

Monitor CCW temperature.

Option 1) Cue: No further actions Monitors CCW temperature and determines temperature less than 125F. No action needs to be taken to stop c c w.

Comments :

Satisfactory Unsatisfactory 0 19 Element:

Conditions :

CUE: Report to examinee as A 0 that alternate cooling has been aligned to "A" D/G.

~

~

Standards :

Examinee will acknowledge that alternate cooling has been aligned to "A" D/G and returns to step 2.e of Att-2.4.

v 20 21 22 23 Page:

8 Job Performance Measure Exam 27-Sep-2004 Comments :

Satisfactory Unsatisfactory 0 Element :

Conditions :

Standards :

Place "A" D/G control switch to Auto Locates and places control switch for "A" D/G to AUTO.

Comments :

Satisfactory Unsatisfactory 0 Element :

Conditions :

Standards :

Depress "A" D/G RESET and D/G FEILD RESET pushbuttons.

Comments :

Locates and depresses the "DIG RESET" and DIG FEILD RESET" for "A" D/G.

Satisfactory 0 Unsatisfactory Element :

Conditions :

Observe restart of "A" D/G

~

~

~~

Standards :

Observe/verify auto restart of "A" DIG by observing frequency and voltage on "A" D/G.

Comments :

Satisfactory 0

Unsatisfactory 0 Element :

Conditions :

CUE: No further action.

Standards :

Comments :

Satisfactory 0

Unsatisfactory 0

9 1 Page:

Job Performance Measure Exam 27-Sep-2004 JPM Questions Question Answer References Reference Type Reference ID Description Ref Flag

I I Page:

Job Performance Measure Exam 16-Sep-2004 JPM NO JR062.026 Restore Power to One Train from D/G per AP-ELEC.3 Revision#:

2 Review Date:

9/16/2004 Location:

Simulator Estimated Time (minutes):

14.00 Candidate:

Evaluator:

Actual Time:

Trainee Performance:

Satisfactory Unsatisfactory Trainee:

Instructor:

Submitted By Reviewed By Date Date

Page:

2 Job Performance Measure Exam 16-Sep-2004 NOTE THE EVALUATOR WILL EXPLAIN THE JPM INITIAL CONDITIONS AND PROVIDE CLARIFICATION AS REQUIRED. THE EXAMINEE MAY USE ANY CONTROLLED COPY REFERENCES THAT ARE NORMALLY AVAILABLE IN THE CONTROL ROOM, INCLUDING LOGS. MAKE ALL WRITTEN REPORTS, ORAL REPORTS, AND LOG ENTRIES AS IF THE EVOLUTION WAS ACTUALLY BEING PERFORMED. THE EVALUATOR WILL BE TAKING NOTES. ASK FOR CLARIFICATION OF JPM REQUREMENTS PRIOR TO THE BEGINNING Initial Conditions:

The plant is in a refueling outage. RCS Loop Level is currently 84 inches with RCS temperature less than 100 degrees. The plant has just experienced a loss of offsite power. DIG "A" started and loaded onto Bus 18, but did not load onto Bus 14. D/G "B" did not start, attempts to start from the MCB did not work. Procedure AP-ELEC.3, LOSS OF 12A AND/OR 12B TRANSFORMER (BELOW 350 DEGREES) has been entered.

Initiating Cues :

You have been directed to attempt to restore power to Bus 14 from D/G "A" per ER-D/G. 1.

3 1 Page:

I 16-sep-2004 Job Performance Measure Exam

==

Description:==

Restore Power to One Train of AC Emergency Buses with Emergency D/G (CT ER JPM Tasks Task ID: 062-033-05-01A Task Standards Bus 14 energized by "A" Diesel Generator Tools :

Terminating Cues References :

ID PRAP AP-ELEC.3 7

PRER ER-D/G. 1 Description Review Date Ref Flag LOSS OF 12A AND/OR 12B TRANSFORMER (BELOW 350 F)

RESTORING D/GS 0

Safety Considerations Consequences of Inadequate Performance:

General Comments :

Start sim in IC-2,84 inches, RHR inservice. Insert MALF GEN04B (TRIP ALL COND) for DIG "B".

Insert MALF GEN09A to fail Bus 14 breaker Auto Close. Insert MALF EDS06 (FAST) for Loss of Offsite Power. Reset Control Room lights on inside MCB, ensure Service Water Pump has auto started, then freeze simulator to give Initial Conditions and Cue.

2 3

4 Page:

4 Job Performance Measure Exam 16-Sep-2004

~

Performance Checklist Element :

Conditions :

Review procedure ER-D/G. 1.

Comments :

Satisfactory 0 Unsatisfactory Standards :

Determine Section 4.4 provides needed direction.

0 Element :

Conditions :

Verifl DIG "A" output voltage approximately 480 volts.

Comments :

Satisfactory Standards :

Check MCB indications for proper voltage.

Unsatisfactory 0 Element :

Conditions :

Check for bus fault indications.

CUE: If examinee requests Electrician or A 0 to locally check bus; cue that no relays are tripped and no indications of damage are seen.

Comments :

Satisfactory Unsatisfactory Standards :

Check MCB alarm panels for fault indications, determine no faults other than loss of offsite power are indicated.

(Annunciators L-5 and L-13 are main indications that no fault occurred.)

Element :

Conditions :

Ensure all bus tie breakers are open.

Comments :

Satisfactory 0 Standards :

Check MCB for open indications:

- Bus 13-Bus 14 tie

- Bus 16-Bus 14 tie Unsatisfactory Element :

Conditions :

Place Bus 14 normal supply breaker to after trip on MCB.

Standards :

Same as element.

6 7

i

  • 8
  • 9 Page:

Job Performance Measure Exam 16-Sep-2004 Comments :

Satisfactory Unsatisfactory Element :

Conditions :

Standards :

Press Overcurrent Reset for Bus

14.

MCB).

Comments :

Locate pushbutton (inside Depress pushbutton.

Satisfactory Unsatisfactory 0 Element :

Conditions :

Standards :

Check auto voltage control properly set.

Comments :

Verify Auto control selected on MCB selector switch.

Verify 480 volts output.

Satisfactory Unsatisfactory 0 Element :

CRITICAL Conditions :

Standards :

Place D/G "A" synchroscope switch to Bus 14 position.

Comments :

Same as element.

Satisfactory 0

Unsatisfactory 0 Element :

CRITICAL Conditions :

Standards :

Manually close D/G "A" feed to Bus 14.

Places D/G A feed to Bus 14 to close. Verifies breaker CUE: No fiuther action.

closes.

Comments :

Satisfactory Unsatisfactory 0

6 1 Page:

Job Performance Measure Exam 16-Sep-2004 JPM Questions Question Answer References Reference Type Reference ID Description Ref Flag

I I

II Page:

Job Performance Measure Exam 16-Sep-2004 I I I

JPM NO JR026.001 Secure Containment Spray Revision #:

6 Review Date:

9/1 Y2004 Location:

Simulator Estimated Time (minutes):

5.00 Candidate:

Evaluator:

Actual Time:

Trainee Performance:

Satisfactory Unsatisfactory Trainee:

Instructor:

Submitted By Date Reviewed By Date

Page:

2 Job Performance Measure Exam 16-Sep-2004 NOTE THE EVALUATOR WILL EXPLAIN THE JPM INITIAL CONDITIONS AND PROVIDE CLARIFICATION AS REQUIRED. THE EXAMINEE MAY USE ANY CONTROLLED COPY REFERENCES THAT ARE NORMALLY AVAILABLE IN THE CONTROL ROOM, INCLUDING LOGS. MAKE ALL WRITTEN REPORTS, ORAL REPORTS, AND LOG ENTRIES AS IF THE EVOLUTION WAS ACTUALLY BEING PERFORMED. THE EVALUATOR WILL BE TAKING NOTES. ASK FOR CLARIFICATION OF JPM REQUIREMENTS PRIOR TO THE BEGINNING Initial Conditions:

The plant was operating at 100% power and experienced a large break LOCA followed by a reactor trip and SI. All necessary equipment functioned properly.

Initiatine Cues :

The plant experienced a large break LOCA. All steps of E-0 and E-1 have been completed up to step 13. The Shift Supervisor directs you to secure Containment Spray per Step 13 of E-1.

3 1 Page:

Job Performance Measure Exam I 16-sep-2004

==

Description:==

Secure Containment Spray (JR026.001)

JPM Tasks Task ID: 026-008-05-Ol A Task Standards Secure Containment Spray Pumps and System.

Tools :

Terminating Cues References :

ID PRE -

E-1 Description LOSS OF REACTOR OR SECONDARY COOLANT Safety Considerations Consequences of Inadeauate Performance:

General Comments :

Review Date Ref Flau 0

Any full power IC. MALF RCS02A, B, C or D (10 000). Complete E-0 and E-1 up to Step 13. Ensure spray energized and Cnmt pressure < 4 psig and NAOH Tank level < 55%. Use Indicator Override SIS37 and set NAOH Tank level to 50%. (IC-52)

1 2

3

  • 4 5

4 1 Page:

Job Performance Measure Exam 16-Sep-2004 Performance Checklist Element :

Conditions :

Obtain a controlled copy of E-1.

Comments :

Satisfactory 0 Standards :

Same as element.

Unsatisfactory 0 Element :

Conditions :

Standards :

Verify Containment Spray Pumps running.

Comments :

Same as element.

Satisfactory Unsatisfactory 0

~~

Element :

Conditions :

Standards :

Verify Containment pressure less MCB meters than 4 psig and NAOH Tank level less than 55%.

Comments :

Satisfactory Unsatisfactory Element :

CRITICAL Conditions :

Standards :

Reset Containment Spray.

Comments :

Depress Containment Spray Reset pushbutton.

Satisfactory Unsatisfactory Element :

Conditions :

Verify NaOH flow - no flow.

Comments :

Satisfactory Standards :

Check FI-930 no flow.

Unsatisfactory Element :

CRITICAL Conditions :

Stop CS Pumps. Place switches in auto.

Standards :

Same as element.

7 Page:

I 16-sep-2004 Job Performance Measure Exam Comments :

Satisfactory Unsatisfactory 0

  • 7 Element:

CRITICAL Close spray isolation valves; MOV-860A, MOV-860B, MOV-860C, MOV-860D.

Comments :

Conditions :

CUE: No further action.

Standards :

MCB switches to close.

Satisfactory Unsatisfactory

EOP E-1 TITLE REV: 29 PAGE 13 of 23 LOSS OF REACTOR OR SECONDARY COOLANT ACTION/EXPECTE RESPONSE NOT OBTAINED "13 Monitor If CNMT Spray Should B e Stopped:

a. CNMT spray pumps - RUNNING
b. Check the following:

o CNMT pressure - LESS THAN 4 PSIG o Sodium hydroxide tank level -

LESS THAN 55%

c. Reset CNMT spray
d. Check NaOH flow (FI-930) - NO FLOW
e. Stop CNMT spray pumps and place in AUTO
f. Close CNMT spray pump discharge valves MOV-860A MOV-860B MOV-860C MOV-860D
a. Go to Step 14.
b. Continue with Step 14. WHEN BOTH conditions satisfied, THEN do Steps 13c through f.
d. Place NaOH tank outlet valve switches to CLOSE.

AOV-836A AOV-836B

I I /

Page:

Job Performance Measure Exam 22-Sep-2 004 I

I JPM NO JC006.010 Perform SFP-RWST Attachment Revision #:

4 Review Date:

9/16/2004 Location:

Aux Bldg:

Estimated Time (minutes):

15.00 Candidate:

Evaluator:

Actual Time:

Trainee Performance:

Satisfactory Unsatisfactory Trainee:

Instructor:

Submitted By Date Reviewed By Date

I 1

l l Page:

Job Performance Measure Exam 22-Sep-2004 NOTE THE EVALUATOR WILL EXPLAIN THE JPM INITIAL CONDITIONS AND PROVIDE CLARIFICATION AS REQUIRED. THE EXAMINEE MAY USE ANY CONTROLLED COPY REFERENCES THAT ARE NORMALLY AVAILABLE IN THE CONTROL ROOM, INCLUDING LOGS. MAKE ALL WRITTEN REPORTS, ORAL REPORTS, AND LOG ENTRIES AS IF THE EVOLUTION WAS ACTUALLY BEING PERFORMED. THE EVALUATOR WILL BE TAKING NOTES. ASK FOR CLARIFICATION OF JPM REQUIREMENTS PRIOR TO THE BEGINNING Initial Conditions:

The plant experienced a LOCA outside of Containment. The LOCA cannot be isolated. Control Room transitioned from ECA-1.2, LOCA OUTSIDE CONTAINMENT, to ECA-1.1, LOSS OF EMERGENCY COOLANT RECIRCULATION.

Initiating Cues :

The CRF directs you to transfer water from SFP to the RWST using Attachment ATT-18.0, e ; r a n s f e r at the Maximum rate (Bypass SFP DIs)

Option 4: Transfer at Normal Rate (Through the SFP DI)

Page:

3 Job Performance Measure Exam 22-Sep-2004

==

Description:==

Perform SFP-RWST Attachment (JC006.010)

JPM Tasks Task ID: 005-017-05-04A Task Standards Tools :

Key Safety Glasses Hard Hat Hearing Protection Terminating Cues Trainee Says Task is Completed Task Completion References :

ID -

PRATT A n - I 8.0 DescriDtion ATTACHMENT SFP - RWST Safety Considerations Radiological Hazard Consequences of Inadequate Performance:

Insufficient water for injection during a Loss of Emergency Coolant Recirculation.

General Comments :

Review Date Ref Flag 0

Estimated Time is 15 minutes for Options 1 and 4. Option 2 adds 5 minutes. Option 3 adds 10 minutes.

r I

4 1 Page:

Job Performance Measure Exam 22-Sep-2004 Performance Checklist 1

Element :

Note Conditions :

Standards :

NOTE: Supply student copy of the attachment,

CUE: Simulate you have a locked valve key.

Comments :

Satisfactory 0

Unsatisfactory 0 2

Element :

Review attachment.

Conditions :

Comments :

Satisfactory Standards :

Same as element.

Unsatisfactory 0 Element :

Conditions :

Standards :

Verify SPF Cooling Lineup.

CUE: A SFP Running Option 1 : Lower suction in service

@gpG;:er suction in service Check SFP Pumps Check SFP Suction Valves (Go to Step 4)

Comments :

Satisfactory Unsatisfactory 0 4

Element :

Conditions :

Standards :

Obtain copy of S-9A.

Review procedure.

Comments :

CUE: Given Examinee Copy Same as Element Satisfactory Unsatisfactory 5

Element :

Check SFP Level Comments :

Conditions :

Standards :

Visual Inspection of Level Same as Element Satisfactory Unsatisfactory c]

1 i

5 1 Page:

Job Performance Measure Exam 22-Sep-2 004

-6 Element :

Conditions :

Standards :

Contact Control about TR 3.7.7 and 3.9.4 Comments :

CUE: Requirements are satisfied sign off Initial Condition Same as Element Satisfactory Unsatisfactory 0 7

Element :

Conditions :

Determine Section 5.6 to be performed.

Comments :

Satisfactory Standards :

Same as Element Unsatisfactory 0 8

Element :

Conditions :

Standards :

Verify Pool Temperature Check Pool Temperature < 1 15 deg F or call MCR to verify.

CUE: Pool Temp 90 deg F Same as Element Comments :

Satisfactory Unsatisfactory 0 9

Element :

Conditions :

Standards :

Check level above weir gate bracket CUE: Level above brackets Checks level Comments :

Satisfactory Unsatisfactory

[7

~~

  • IO Element:

CRITICAL Conditions :

Standards :

Open V-782 Locate valve Same as Element Simulator opening CUE: Valve no longer turns in that direction Comments :

Satisfactory Unsatisfactory

~

~

~

1 Element:

CRITICAL Conditions :

Standards :

Close V-781 Locates valve Same as Element Simulates closing CUE: Valve no longer turns in that direction

Page:

I 22-sep-2004 Job Performance Measure Exam Comments :

Satisfactory Unsatisfactory 0 12 Element:

Conditions :

Standards :

Observe note.

CUE:

Same as element.

OPTION #3 = Transfer at maximum rate.

OPTION #4 = Transfer through SFP DI.

e Proceed to next step.

OPTION #4 - proceed to step 20.

Comments :

Satisfactory Unsatisfactory 0

~

~

~

~

  • 13 Element:

CRITICAL Conditions :

Standards :

Unlock and close V-804.

CUE: Valve is unlocked. Valve no longer turns in that direction.

CUE:(If student requests eSOMS location) eSOMS gives valve location at: AB INTER, SFP HEAT EXCH AREA, ELEV 4 Locate valve.

Simulate unlocking and closing.

Comments :

Satisfactory 0

Unsatisfactory

~

~

  • 14 Element:

CRITICAL Conditions :

Standards :

Open V-789.

CUE: Valve no longer turns in that direction.

Simulate opening valve.

Locate valve.

CUE:(If student requests eSOMS location) eSOMS gives valve location at: AB INTER, SFP FILTER ROOM AREA, ELEV 1 Comments :

Satisfactory Unsatisfactory 0

-15

  • 16
  • 17
  • I8 7 1 Page:

Job Performance Measure Exam 22-Sep-2004 Element :

CRITICAL Conditions :

Standards :

Close V-790.

CUE: Valve no longer turns in that direction.

Simulate closing valve.

CUE:(If student requests eSOMS location) eSOMS gives valve location at: AB INTER, SFP FILTER ROOM AREA, ELEV 1 Locate valve.

Comments :

Satisfactory n Unsatisfactory

[7 Element :

CRITICAL Conditions :

Standards :

Close V-796.

CUE: Valve no longer turns in that direction.

Simulate closing valve.

CUE:(If student requests eSOMS location) eSOMS gives valve location at: AB INTER, SFP FILTER ROOM AREA, ELEV 1 Locate valve.

Comments :

Satisfactory 0 Unsatisfactory 0 Element :

CRITICAL Conditions :

Standards :

Open V-797.

CUE: Valve no longer turns in that direction.

Simulate opening valve.

CUE:(If student requests eSOMS location) eSOMS gives valve location at: AB INTER, SFP FILTER ROOM AREA, ELEV 5 Locate valve.

Comments :

Satisfactory Unsatisfactory 0 Element :

CRITICAL Conditions :

Standards :

Close V-798A.

CUE: Valve no longer turns in that direction.

Simulate closing valve.

Locate valve.

CUE:(If student requests eSOMS location) eSOMS gives valve location at: AB INTER, SFP FILTER ROOM AREA, ELEV 5

Page:

8 Job Performance Measure Exam 22-Sep-2004 Comments :

Satisfactory 0

Unsatisfactory

  • 19 Element:

CRITICAL Conditions :

Standards :

Close V-802.

CUE: Valve no longer turns in that direction.

Simulate closing valve.

Locate valve.

CUE:(If student requests eSOMS location) eSOMS gives valve location at: AB INTER, SFP FILTER ROOM AREA, ELEV 5 Comments :

Satisfactory 0

Unsatisfactory c]

  • 20 Element:

CRITICAL Conditions :

Observe caution.

Comments :

Satisfactory Standards :

Same as element.

Unsatisfactory

  • 21 Element :

CRITICAL Conditions :

Slowly open V-803 and close V-804.

reads 60 gpm.

CUE OPTION #4: Flow meter CUE BOTH OPTIONS: Secure transferring water to RWST.

Standards :

Locates valves.

Simulate unlocking and operating valves.

IF performing OPTION #4, indicate that meter is monitored (for 60 gpm flow)=

CUE:(If student requests eSOMS location) eSOMS gives valve location at: AB INTER, SFP HEAT EXCH AREA ELEV 4 for both valves Comments :

Satisfactory Unsatisfactory

I 1

9 1 Page:

Job Performance Measure Exam 22-Sep-2 004

.- *22 Element :

CRITICAL Close V-803.

Conditions :

Standards :

CUE: Valve no longer turns in that direction.

Simulate closing valve and CUE:(If student requests eSOMS location) eSOMS gives valve location at: AB INTER, SFP HEAT EXCH AREA, ELEV 4 Locate valve.

locking.

Cue: No further actions Comments :

Satisfactory Unsatisfactory

I Page:

1 Job Performance Measure Exam 21-Sep-2004 JPM NO JC062.023 Dilute BAST following a Loss of All AC Revision #:

2 Review Date:

9/14/2004 Location:

Aux Bldg Estimated Time (minutes):

Candidate:

18.00 Evaluator:

Actual Time:

Trainee Performance:

Satisfactory Unsatisfactory Trainee:

Instructor:

Submitted By Date Reviewed By Date

21 -Sep-2 004 Job Performance Measure Exam Page:

2 NOTE THE EVALUATOR WILL EXPLAIN THE JPM INITIAL CONDITIONS AND PROVIDE CLARIFICATION AS REQUIRED. THE EXAMINEE MAY USE ANY CONTROLLED COPY REFERENCES THAT ARE NORMALLY AVAILABLE IN THE CONTROL ROOM, INCLUDING LOGS. MAKE ALL WRITTEN REPORTS, ORAL REPORTS, AND LOG ENTRIES AS IF THE EVOLUTION WAS ACTUALLY BEING PERFORMED. THE EVALUATOR WILL BE TAKING NOTES. ASK FOR CLARIFICATION OF JPM REQUIREMENTS PRIOR TO THE BEGINNING Ini tia 1 Conditions :

The plant experienced a loss of all AC. BAST temperature is 153 degrees Fahrenheit.

Initiating Cues :

The plant experienced a loss of all AC. The BAST is at 153 degrees Fahrenfeit. The Shift Supervisor directs you to dilute the BAST per ER-BA. 1.

The Control Room has verified normal system alignment for steps 4.1.1 through 4.1.4, you are to begin actions at step 4.1.5. DO NOT MANIPULATE ANY EQUIPMENT.

3 1 Page:

Job Performance Measure Exam 21 -Sep-2004

==

Description:==

Dilute BAST Following LOSS OF ALL AC (JC062.023)

JPM Tasks Task ID: 062-029-05-04B Task Standards In accordance with the procedure Tools :

Safety Glasses Hard Hat Hearing Protection Terminating Cues Task Completion Trainee Says Task is Completed References :

ID PRER ER-BA. 1 Description Review Date Ref Flag BAST TEMPERATURE CONCERNS - LOSS OF ALL AC 0

Safety Considerations Radiological Hazard Consequences of Inadequate Performance:

General Comments :

Radiation area entry required.

Handout COPY of ER-BA. 1.

4 1 Page:

Job Performance Measure Exam 21-Sep-2004 Performance Checklist

  • 1 Element:

CRITICAL Locate and open MOV-826A AND MOV-826C.

Conditions :

Standards :

CUE: (As each valve is Simulate depressing manipulated) Valve no longer turns declutching device and in that direction. (Cue for valve opening valve with stem indication if examinee handwheel.

indicates observing for motion.)

CUE: (If student requests eSOMS location) eSOMS gives valve location at: AB INTERMEDIATE EAST STAIRWAY AREA. ELEV (For V-826A): 4, (For V-826C): 6.

Comments :

Satisfactory 0

Unsatisfactory 0

~~

~

~~~

  • 2 Element:

CRITICAL Conditions :

Standards :

Locate and crack open MOV-826B OR MOV-826D.

Valve stem moves.

declutching device and CUE: (If goes in open direction)

Simulate depressing opening valve with handwheel.

CUE: (If student requests eSOMS location) eSOMS gives valve location at: AB INTERMEDIATE EAST STAIRWAY AREA, ELEV (For V-826B): 4, (For V-826D): 6 Comments :

Satisfactory Unsatisfactory 0 3

Element :

Conditions :

Standards :

CUE for continuation CUE:

If examinee monitors BAST overflow piping - Water flow is occurring.

If examinee contacts Control Room - RWST level has decreased by 2%.

Comments :

Satisfactory Unsatisfactory

Page:

5 Job Performance Measure Exam 21-Sep-2004 CRITICAL Conditions :

Standards :

- 4 Element:

Close MOV-826B or MOV-826D NOTE: Order of closure for 826 (whichever was previously valves is not critical.

opened).

opened.

CUE: Valve no longer turns in that direction.

Simulate using handwheel to close the valve that was Comments :

Satisfactory 0 Unsatisfactory 0

~~

  • 5 Element:

CRITICAL Conditions :

Standards :

Close MOV-826A AND MOV-826C.

longer turns in that direction.

close both valves.

CUE: (For each valve) Valve no Simulate using handwheels to CUE: (If student requests eSOMS location) eSOMS gives valve location at: AB INTERMEDIATE EAST STAIRWAY AREA. ELEV (For v-826A): 4, (For V-826C): 6 CUE: No further action.

Comments :

Satisfactory n Unsatisfactory 0 JPM Questions Question Answer References Reference Type Reference ID Description Ref Flag