27-Sep-2004 Job Performance Measure Exam Page:

ll JPM NO JC076.007 Perform ATTACHMENT NO SW PUMPS Revision #: 0 Review Date:

Location: Simulator Estimated Time (minutes): 10.00 Candidate:

Evaluator:

>L Actual Time:

Trainee Performance: Satisfactory Unsatisfactory Trainee:

Instructor:

Submitted By Date Reviewed By Date

27-Sep-2004 Page: 2 Job Performance Measure Exam NOTE THE EVALUATOR WILL EXPLAIN THE JPM INITIAL CONDITIONS AND PROVIDE CLARIFICATION AS REQUIRED. THE EXAMINEE MAY USE ANY CONTROLLED COPY REFERENCES THAT ARE NORMALLY AVAILABLE IN THE CONTROL ROOM, INCLUDING LOGS. MAKE ALL WRITTEN REPORTS, ORAL REPORTS, AND LOG ENTRIES AS IF THE EVOLUTION WAS ACTUALLY BEING PERFORMED. THE EVALUATOR WILL BE TAKING NOTES. ASK FOR CLARIFICATION OF JPM REQUIREMENTS PRIOR TO THE BEGINNING Initia 1 Conditions:

Option 1: The plant was at 100% power when all SW pumps tripped and could not be restarted.

=

The crew tripped the Reactor. The E-0 immediate actions have been performed. The crew has just entered ES-0.1, "REACTOR TRIP RESPONSE."

The plant was at 100% power when Alarm L- 12, "Condenser Pit or Screenhouse High was received followed by L-15 and L-23, "Bus 17/18 Undervoltage" and L-5, "Safeguard Bus Main Breaker Overcurrent Trip". The E-0 immediate actions have been performed. The crew has just entered ES-0.1, "REACTOR TRIP RESPONSE."

L.

Initiating Cues :

The CRF directs you to perform Att-2.4 "ATTACHMENT NO SW PUMPS" while the rest of the crew continues with ES-0.1 "REACTOR TRIP RESPONSE".

2 7-Sep-2004 Page: 3 Job Performance Measure Exam

-u

Description:

Respond to a Total Loss of SW JPM Tasks Task ID: 076-004-05-01 Task Standards In accordance with the procedure Tools :

Installed indication Procedures Installed switches/pushbuttons Terminating Cues Task Completion

\.

References :

-ID Descrbtion Review Date Ref Flag PRATT ATT-2.4 ATTACHMENT NO SW PUMPS 0 Safety Considerations Conseauences of Inadequate Performance:

Equipment Damage Thermal design limit challenge Procedure Violation General Comments :

Simulator setup with Reactor tripped from 100% power, Option 1 - All service water pumps tripped,

& 18 de-energized and both DIGS running unloaded. (Malf CRC03A, 200,000; Malf L,

~

I - - I 2 7-Sep-2004 Page:

Job Performance Measure Exam 4 1 Performance Checklist 1 Element : Conditions : Standards :

Cue CUE: Give examinee a copy of ATT-2.4 ATTACHMENT NO SW PUMPS.

Comments :

Satisfactory Unsatisfactory 2 Element : Conditions : Standards :

Note - Steps 1 through 5 should Ensure examinee reads note be performed promptly to avoid and performs steps in a equipment damage. prompt manner.

Comments :

Satisfactory 0 Unsatisfactory 0 Element : CRITICAL Conditions : Standards :

Trip both RCPs. Locates control switches for RCPs and trips both RCPs Comments :

Satisfactory 0 Unsatisfactory 0

  • 4 Element: CRITICAL Conditions : Standards :

Determine if any D/G running Option 1) No D/G running (Go to Same as Element.

without alternate cooling.

e o t h D/G running (Go to Comments :

Satisfactory n Unsatisfactory

  • 5 Element: CRITICAL Conditions : Standards :

Pull stop the affected D/G. D/Gs can be shutdown in any Locates control switch for A order. D/G and takes switch to pull stop.

L Comments:

Satisfactory n Unsatisfactory

2 7-Sep-2004 Page:

Job Performance Measure Exam 5 1

  • 6 Element: CRITICAL Conditions : Standards :

Immediately depress voltage Locates voltage shutdown shutdown pushbutton for A D/G pushbutton for A D/G and immediately depresses pushbutton.

Comments :

Satisfactory n Unsatisfactory

  • 7 Element: CRITICAL Conditions : Standards :

Pull stop the affected D/G. Locates control switch for B DIG and takes switch to pull stop.

Comments :

Satisfactory Unsatisfactory 0

~

  • 8 Element : CRITICAL Conditions : Standards :

Immediately depress voltage Locates voltage shutdown shutdown pushbutton for B D/G pushbutton for B D/G and immediately depresses pushbutton.

Comments :

Satisfactory 0 Unsatisfactory 0 9 Element : Conditions : Standards :

Directs an A 0 to align alternate Contacts A 0 and directs A 0 cooling to both D/Gs using to align alternate cooling to ER-D/G.2. D/Gs per ER-D/G.2.

Comments :

Satisfactory Unsatisfactory 0 10 Element : Conditions : Standards :

Determine if Bus 17 has been Based on initial conditions potentially damaged. determines that Bus 17 has been possibly damaged, Directs A 0 to locally open c breaker 1B3, B D/G Is01 Bkr to Bus 17 in B DIG room.

2 7-Sep-2004 Page: 6 Job Performance Measure Exam Comments :

Satisfactory 0 Unsatisfactory 11 Element: Conditions : Standards :

Close Letdown isolation, Locates control switch for AOV-427 AOV-427 and places control switch in close.

Comments :

Satisfactory Unsatisfactory 0 12 Element: Conditions : Standards :

Close excess letdown, HCV- 123 Locates manual controller for HCV- 123 and adjusts ( or verifies) controller has "0" demand and no pressure indicated on PI- 121.

Comments :

Satisfactory Unsatisfactory 0

  • 13 Element : CRITICAL Conditions : Standards :

Close both MSIVs. Locates control switch for MSIVS (AOV-35 17 &

AOV-35 16) and closes both MSIVs.

CUE: The other operator will control temperature using ARV's.

Comments :

Satisfactory 0 Unsatisfactory 0

  • 14 Element : CRITICAL Conditions : Standards :

Pull stop control switches for both Locates control swithes for A MDAFW pumps. and B AFW pumps and places both switches in pull stop.

. Comments :

Satisfactory 0 Unsatisfactory 0

I I 2 7-Sep-2004 Page:

Job Performance Measure Exam 71 L

  • 15 Element: CRITICAL Conditions : Standards :

Pull stop control switches for all Locates control switches for four CNMT Recirc Fans. all four CNMT Recirc Fans and places switches in pull stop.

Comments :

Satisfactory 0 Unsatisfactory 0 16 Element: Conditions : Standards :

Pull stop control switches for both Locates control switches for MFW pumps. both MFW pumps and places switches in pull stop.

Comments :

Satisfactory Unsatisfactory 0 17 Element: Conditions : Standards :

Pull stop control switches for Locates control switches for

. Condensate Pumps. Condensate pumps and places all three switches in pull stop.

Comments :

Satisfactory Unsatisfactory 0 18 Element: Conditions : Standards :

Monitor CCW temperature. Option 1) Cue: No further actions Monitors CCW temperature and determines temperature less than 125F. No action needs to be taken to stop ccw.

Comments :

Satisfactory Unsatisfactory 0

~ ~

19 Element: Conditions : Standards :

CUE: Report to examinee as A 0 Examinee will acknowledge that alternate cooling has been that alternate cooling has aligned to "A"D/G. been aligned to "A"D/G and

. returns to step 2.e of Att-2.4.

27-Sep-2004 Page: 8 Job Performance Measure Exam v

Comments :

Satisfactory Unsatisfactory 0 20 Element : Conditions : Standards :

Place "A"D/G control switch to Locates and places control Auto switch for "A"D/G to AUTO.

Comments :

Satisfactory Unsatisfactory 0 21 Element : Conditions : Standards :

Depress "A"D/G RESET and Locates and depresses the D/G FEILD RESET pushbuttons. "DIG RESET" and DIG FEILD RESET" for "A"D/G.

Comments :

Satisfactory 0 Unsatisfactory

~ ~ ~~

22 Element : Conditions : Standards :

Observe restart of "A"D/G Observe/verify auto restart of "A"DIG by observing frequency and voltage on "A" D/G.

Comments :

Satisfactory 0 Unsatisfactory 0 23 Element : Conditions : Standards :

CUE: No further action.

Comments :

Satisfactory 0 Unsatisfactory 0

27-Sep-2004 Page:

Job Performance Measure Exam 9 1 JPM Questions Question Answer References Reference Type Reference ID Description Ref Flag

16-Sep-2004 Job Performance Measure Exam Page:

II JPM NO JR062.026 Restore Power to One Train from D/G per AP-ELEC.3 Revision#: 2 Review Date: 9/16/2004 Location: Simulator Estimated Time (minutes): 14.00 Candidate:

Evaluator:

Actual Time:

Trainee Performance: Satisfactory Unsatisfactory Trainee:

Instructor:

Submitted By Date Reviewed By Date

16-Sep-2004 Page: 2 Job Performance Measure Exam NOTE THE EVALUATOR WILL EXPLAIN THE JPM INITIAL CONDITIONS AND PROVIDE CLARIFICATION AS REQUIRED. THE EXAMINEE MAY USE ANY CONTROLLED COPY REFERENCES THAT ARE NORMALLY AVAILABLE IN THE CONTROL ROOM, INCLUDING LOGS. MAKE ALL WRITTEN REPORTS, ORAL REPORTS, AND LOG ENTRIES AS IF THE EVOLUTION WAS ACTUALLY BEING PERFORMED. THE EVALUATOR WILL BE TAKING NOTES. ASK FOR CLARIFICATION OF JPM REQUREMENTS PRIOR TO THE BEGINNING Initial Conditions:

The plant is in a refueling outage. RCS Loop Level is currently 84 inches with RCS temperature less than 100 degrees. The plant has just experienced a loss of offsite power. DIG "A" started and loaded onto Bus 18, but did not load onto Bus 14. D/G "B" did not start, attempts to start from the MCB did not work. Procedure AP-ELEC.3, LOSS OF 12A AND/OR 12B TRANSFORMER (BELOW 350 DEGREES) has been entered.

Initiating Cues :

You have been directed to attempt to restore power to Bus 14 from D/G "A" per ER-D/G. 1.

I 16-sep-2004 Job Performance Measure Exam Page:

3 1

Description:

Restore Power to One Train of AC Emergency Buses with Emergency D/G (CT ER JPM Tasks Task ID: 062-033-05-01A Task Standards Bus 14 energized by "A" Diesel Generator Tools :

Terminating Cues References :

7 ID Description Review Date Ref Flag PRAP AP-ELEC.3 LOSS OF 12A AND/OR 12B TRANSFORMER 0 (BELOW 350 F)

PRER ER-D/G. 1 RESTORING D/GS Safety Considerations Consequences of Inadequate Performance:

General Comments :

Start sim in IC-2,84 inches, RHR inservice. Insert MALF GEN04B (TRIP ALL COND) for DIG "B".

Insert MALF GEN09A to fail Bus 14 breaker Auto Close. Insert MALF EDS06 (FAST) for Loss of Offsite Power. Reset Control Room lights on inside MCB, ensure Service Water Pump has auto started, then freeze simulator to give Initial Conditions and Cue.

16-Sep-2004 Page: 4 Job Performance Measure Exam

~

Performance Checklist Element : Conditions : Standards :

Review procedure ER-D/G. 1. Determine Section 4.4 provides needed direction.

Comments :

Satisfactory 0 Unsatisfactory 0 2 Element : Conditions : Standards :

Verifl DIG "A"output voltage Check MCB indications for approximately 480 volts. proper voltage.

Comments :

Satisfactory Unsatisfactory 0 3 Element : Conditions : Standards :

Check for bus fault indications. CUE: If examinee requests Check MCB alarm panels for Electrician or A 0 to locally check fault indications, determine bus; cue that no relays are tripped no faults other than loss of and no indications of damage are offsite power are indicated.

seen. (Annunciators L-5 and L-13 are main indications that no fault occurred.)

Comments :

Satisfactory Unsatisfactory 4 Element : Conditions : Standards :

Ensure all bus tie breakers are Check MCB for open open. indications:

- Bus 13-Bus 14 tie

- Bus 16-Bus 14 tie Comments :

Satisfactory 0 Unsatisfactory Element : Conditions : Standards :

Place Bus 14 normal supply Same as element.

breaker to after trip on MCB.

16-Sep-2004 Page:

Job Performance Measure Exam Comments :

Satisfactory Unsatisfactory 6 Element : Conditions : Standards :

Press Overcurrent Reset for Bus Locate pushbutton (inside

14. MCB).

Depress pushbutton.

Comments :

Satisfactory Unsatisfactory 0 7 Element : Conditions : Standards :

Check auto voltage control Verify Auto control selected properly set. on MCB selector switch.

Verify 480 volts output.

Comments :

Satisfactory Unsatisfactory 0 i

  • 8 Element : CRITICAL Conditions : Standards :

Place D/G "A"synchroscope Same as element.

switch to Bus 14 position.

Comments :

Satisfactory 0 Unsatisfactory 0

  • 9 Element : CRITICAL Conditions : Standards :

Manually close D/G "A"feed to Places D/G A feed to Bus 14 Bus 14. to close. Verifies breaker CUE: No fiuther action. closes.

Comments :

Satisfactory Unsatisfactory 0

16-Sep-2004 Job Performance Measure Exam Page:

61 JPM Questions Question Answer References Reference Type Reference ID Description Ref Flag

I I I

I 16-Sep-2004 Job Performance Measure Exam Page:

II I

JPM NO JR026.001 Secure Containment Spray Revision #: 6 Review Date: 9/1Y2004 Location: Simulator Estimated Time (minutes): 5.00 Candidate:

Evaluator:

Actual Time:

Trainee Performance: Satisfactory Unsatisfactory Trainee:

Instructor:

Submitted By Date Reviewed By Date

16-Sep-2004 Page: 2 Job Performance Measure Exam NOTE THE EVALUATOR WILL EXPLAIN THE JPM INITIAL CONDITIONS AND PROVIDE CLARIFICATION AS REQUIRED. THE EXAMINEE MAY USE ANY CONTROLLED COPY REFERENCES THAT ARE NORMALLY AVAILABLE IN THE CONTROL ROOM, INCLUDING LOGS. MAKE ALL WRITTEN REPORTS, ORAL REPORTS, AND LOG ENTRIES AS IF THE EVOLUTION WAS ACTUALLY BEING PERFORMED. THE EVALUATOR WILL BE TAKING NOTES. ASK FOR CLARIFICATION OF JPM REQUIREMENTS PRIOR TO THE BEGINNING Initial Conditions:

The plant was operating at 100% power and experienced a large break LOCA followed by a reactor trip and SI. All necessary equipment functioned properly.

Initiatine Cues :

The plant experienced a large break LOCA. All steps of E-0 and E-1 have been completed up to step 13. The Shift Supervisor directs you to secure Containment Spray per Step 13 of E-1.

I 16-sep-2004 Job Performance Measure Exam Page:

31

==

Description:==

Secure Containment Spray (JR026.001)

JPM Tasks Task ID: 026-008-05-Ol A Task Standards Secure Containment Spray Pumps and System.

Tools :

Terminating Cues References :

-ID Description Review Date Ref Flau PRE E- 1 LOSS OF REACTOR OR SECONDARY 0 COOLANT Safety Considerations Consequences of Inadeauate Performance:

General Comments :

Any full power IC. MALF RCS02A, B, C or D (10 000). Complete E-0 and E-1 up to Step 13. Ensure spray energized and Cnmt pressure < 4 psig and NAOH Tank level < 55%. Use Indicator Override SIS37 and set NAOH Tank level to 50%. (IC-52)

16-Sep-2004 Page:

Job Performance Measure Exam 4 1 Performance Checklist 1 Element : Conditions : Standards :

Obtain a controlled copy of E-1. Same as element.

Comments :

Satisfactory 0 Unsatisfactory 0 2 Element : Conditions : Standards :

Verify Containment Spray Pumps Same as element.

running.

Comments :

Satisfactory Unsatisfactory 0

~~

3 Element : Conditions : Standards :

Verify Containment pressure less MCB meters than 4 psig and NAOH Tank level less than 55%.

Comments :

Satisfactory Unsatisfactory

  • 4 Element : CRITICAL Conditions : Standards :

Reset Containment Spray. Depress Containment Spray Reset pushbutton.

Comments :

Satisfactory Unsatisfactory 5 Element : Conditions : Standards :

Verify NaOH flow - no flow. Check FI-930 no flow.

Comments :

Satisfactory Unsatisfactory Element : CRITICAL Conditions : Standards :

Stop CS Pumps. Place switches in Same as element.

auto.

I 16-sep-2004 Job Performance Measure Exam Page:

7 Comments :

Satisfactory Unsatisfactory 0

  • 7 Element: CRITICAL Conditions : Standards :

Close spray isolation valves; CUE: No further action. MCB switches to close.

MOV-860A, MOV-860B, MOV-860C, MOV-860D.

Comments :

Satisfactory Unsatisfactory

EOP TITLE REV: 29 E-1 LOSS OF REACTOR OR SECONDARY COOLANT PAGE 13 of 23 ACTION/EXPECTE RESPONSE NOT OBTAINED "13 Monitor If CNMT S p r a y Should B e Stopped:

a. CNMT spray pumps - RUNNING a. Go to Step 14.
b. Check the following: b . Continue with Step 14. WHEN BOTH conditions satisfied, THEN o CNMT pressure - LESS THAN do Steps 13c through f .

4 PSIG o Sodium hydroxide tank level -

LESS THAN 55%

c. Reset CNMT spray
d. Check NaOH flow (FI-930) - NO d. Place NaOH tank outlet valve FLOW switches to CLOSE.

AOV-836A AOV-836B

e. Stop CNMT spray pumps and place in AUTO
f. Close CNMT spray pump discharge valves MOV-860A MOV-860B MOV-860C MOV-860D

I 22-Sep-2 004 Page:

Job Performance Measure Exam I I /

I JPM NO JC006.010 Perform SFP-RWST Attachment Revision #: 4 Review Date: 9/16/2004 Location: Aux Bldg:

Estimated Time (minutes): 15.00 Candidate:

Evaluator:

Actual Time:

Trainee Performance: Satisfactory Unsatisfactory Trainee:

Instructor:

Submitted By Date Reviewed By Date

I 1 22-Sep-2004 Page:

Job Performance Measure Exam ll NOTE THE EVALUATOR WILL EXPLAIN THE JPM INITIAL CONDITIONS AND PROVIDE CLARIFICATION AS REQUIRED. THE EXAMINEE MAY USE ANY CONTROLLED COPY REFERENCES THAT ARE NORMALLY AVAILABLE IN THE CONTROL ROOM, INCLUDING LOGS. MAKE ALL WRITTEN REPORTS, ORAL REPORTS, AND LOG ENTRIES AS IF THE EVOLUTION WAS ACTUALLY BEING PERFORMED. THE EVALUATOR WILL BE TAKING NOTES. ASK FOR CLARIFICATION OF JPM REQUIREMENTS PRIOR TO THE BEGINNING Initial Conditions:

The plant experienced a LOCA outside of Containment. The LOCA cannot be isolated. Control Room transitioned from ECA-1.2, LOCA OUTSIDE CONTAINMENT, to ECA-1.1,LOSS OF EMERGENCY COOLANT RECIRCULATION.

Initiating Cues :

The CRF directs you to transfer water from SFP to the RWST using Attachment ATT-18.0, e ; r a n s f e r at the Maximum rate (Bypass SFP DIs)

Option 4: Transfer at Normal Rate (Through the SFP DI)

22-Sep-2004 Page: 3 Job Performance Measure Exam

==

Description:==

Perform SFP-RWST Attachment (JC006.010)

JPM Tasks Task ID: 005-017-05-04A Task Standards Tools :

Key Safety Glasses Hard Hat Hearing Protection Terminating Cues Trainee Says Task is Completed Task Completion References :

-ID DescriDtion Review Date Ref Flag PRATT A n - I 8.0 ATTACHMENT SFP - RWST 0 Safety Considerations Radiological Hazard Consequences of Inadequate Performance:

Insufficient water for injection during a Loss of Emergency Coolant Recirculation.

General Comments :

Estimated Time is 15 minutes for Options 1 and 4. Option 2 adds 5 minutes. Option 3 adds 10 minutes.

r I 22-Sep-2004 Page:

Job Performance Measure Exam 4 1 Performance Checklist 1 Element : Conditions : Standards :

Note NOTE: Supply student copy of the attachment ,

CUE: Simulate you have a locked valve key.

Comments :

Satisfactory 0 Unsatisfactory 0 2 Element : Conditions : Standards :

Review attachment. Same as element.

Comments :

Satisfactory Unsatisfactory 0 Element : Conditions : Standards :

Verify SPF Cooling Lineup. CUE: A SFP Running Check SFP Pumps Option 1 : Lower suction in service Check SFP Suction Valves

@gpG;:er suction in service (Go to Step 4)

Comments :

Satisfactory Unsatisfactory 0 4 Element : Conditions : Standards :

Obtain copy of S-9A. CUE: Given Examinee Copy Same as Element Review procedure.

Comments :

Satisfactory Unsatisfactory 5 Element : Conditions : Standards :

Check SFP Level Visual Inspection of Level Same as Element Comments :

Satisfactory Unsatisfactory c]

1 i 22-Sep-2 004 Page:

Job Performance Measure Exam 51

-6 Element : Conditions : Standards :

Contact Control about TR 3.7.7 CUE: Requirements are satisfied Same as Element and 3.9.4 sign off Initial Condition Comments :

Satisfactory Unsatisfactory 0 7 Element : Conditions : Standards :

Determine Section 5.6 to be Same as Element performed.

Comments :

Satisfactory Unsatisfactory 0 8 Element : Conditions : Standards :

Verify Pool Temperature Check Pool Temperature < 115 Same as Element deg F or call MCR to verify.

CUE: Pool Temp 90 deg F Comments :

Satisfactory Unsatisfactory 0 9 Element : Conditions : Standards :

Check level above weir gate CUE: Level above brackets Checks level bracket Comments :

Satisfactory Unsatisfactory [7

~~

  • IO Element: CRITICAL Conditions : Standards :

Open V-782 Locate valve Same as Element Simulator opening CUE: Valve no longer turns in that direction Comments :

Satisfactory Unsatisfactory

~ _ _ _ ~ ~

1 Element: CRITICAL Conditions : Standards :

Close V-781 Locates valve Same as Element Simulates closing CUE: Valve no longer turns in that direction

I 22-sep-2004 Job Performance Measure Exam Page:

Comments :

Satisfactory Unsatisfactory 0 12 Element: Conditions : Standards :

Observe note. CUE: Same as element.

e step.

Proceed to next OPTION #4 - proceed to step 20.

OPTION #3 = Transfer at maximum rate.

OPTION #4 = Transfer through SFP DI.

Comments :

Satisfactory Unsatisfactory 0

~ ~ ~ ~

  • 13 Element: CRITICAL Conditions : Standards :

Unlock and close V-804. CUE: Valve is unlocked. Valve no Locate valve.

longer turns in that direction. Simulate unlocking and closing.

CUE:(If student requests eSOMS

. location) eSOMS gives valve location at: AB INTER, SFP HEAT EXCH AREA, ELEV 4 Comments :

Satisfactory 0 Unsatisfactory

- ~ ~

  • 14 Element: CRITICAL Conditions : Standards :

Open V-789. CUE: Valve no longer turns in that Locate valve.

direction. Simulate opening valve.

CUE:(If student requests eSOMS location) eSOMS gives valve location at: AB INTER, SFP FILTER ROOM AREA, ELEV 1 Comments :

Satisfactory Unsatisfactory 0

22-Sep-2004 Page:

Job Performance Measure Exam 7 1

-15 Element : CRITICAL Conditions : Standards :

Close V-790. CUE: Valve no longer turns in that Locate valve.

direction. Simulate closing valve.

CUE:(If student requests eSOMS location) eSOMS gives valve location at: AB INTER, SFP FILTER ROOM AREA, ELEV 1 Comments :

Satisfactory n Unsatisfactory [7

  • 16 Element : CRITICAL Conditions : Standards :

Close V-796. CUE: Valve no longer turns in that Locate valve.

direction. Simulate closing valve.

CUE:(If student requests eSOMS location) eSOMS gives valve location at: AB INTER, SFP FILTER ROOM AREA, ELEV 1 Comments :

Satisfactory 0 Unsatisfactory 0

  • 17 Element : CRITICAL Conditions : Standards :

Open V-797. CUE: Valve no longer turns in that Locate valve.

direction. Simulate opening valve.

CUE:(If student requests eSOMS location) eSOMS gives valve location at: AB INTER, SFP FILTER ROOM AREA, ELEV 5 Comments :

Satisfactory Unsatisfactory 0

  • I8 Element : CRITICAL Conditions : Standards :

Close V-798A. CUE: Valve no longer turns in that Locate valve.

direction. Simulate closing valve.

CUE:(If student requests eSOMS location) eSOMS gives valve location at: AB INTER, SFP FILTER ROOM AREA, ELEV 5

22-Sep-2004 Page: 8 Job Performance Measure Exam Comments :

Satisfactory 0 Unsatisfactory

  • 19 Element: CRITICAL Conditions : Standards :

Close V-802. CUE: Valve no longer turns in that Locate valve.

direction. Simulate closing valve.

CUE:(If student requests eSOMS location) eSOMS gives valve location at: AB INTER, SFP FILTER ROOM AREA, ELEV 5 Comments :

Satisfactory 0 Unsatisfactory c]

  • 20 Element: CRITICAL Conditions : Standards :

Observe caution. Same as element.

Comments :

Satisfactory Unsatisfactory

  • 21 Element : CRITICAL Conditions : Standards :

Slowly open V-803 and close CUE OPTION #4:Flow meter Locates valves.

V-804. reads 60 gpm. Simulate unlocking and operating valves.

IF performing OPTION #4, indicate that meter is monitored (for 60 gpm CUE BOTH OPTIONS: Secure flow)=

transferring water to RWST.

CUE:(If student requests eSOMS location) eSOMS gives valve location at: AB INTER, SFP HEAT EXCH AREA ELEV 4 for both valves Comments :

. Satisfactory Unsatisfactory

I 1 22-Sep-2 004 Page:

Job Performance Measure Exam 9 1

.-*22 Element : CRITICAL Conditions : Standards :

Close V-803. CUE: Valve no longer turns in that Locate valve.

direction. Simulate closing valve and locking.

CUE:(If student requests eSOMS location) eSOMS gives valve location at: AB INTER, SFP HEAT EXCH AREA, ELEV 4 Cue: No further actions Comments :

Satisfactory Unsatisfactory

I 21-Sep-2004 Page: 1 Job Performance Measure Exam JPM NO JC062.023 Dilute BAST following a Loss of All AC Revision #: 2 Review Date: 9/14/2004 Location: Aux Bldg Estimated Time (minutes): 18.00 Candidate:

Evaluator:

Actual Time:

Trainee Performance: Satisfactory Unsatisfactory Trainee:

Instructor:

Submitted By Date Reviewed By Date

21-Sep-2004 Job Performance Measure Exam Page: 2 NOTE THE EVALUATOR WILL EXPLAIN THE JPM INITIAL CONDITIONS AND PROVIDE CLARIFICATION AS REQUIRED. THE EXAMINEE MAY USE ANY CONTROLLED COPY REFERENCES THAT ARE NORMALLY AVAILABLE IN THE CONTROL ROOM, INCLUDING LOGS. MAKE ALL WRITTEN REPORTS, ORAL REPORTS, AND LOG ENTRIES AS IF THE EVOLUTION WAS ACTUALLY BEING PERFORMED. THE EVALUATOR WILL BE TAKING NOTES. ASK FOR CLARIFICATION OF JPM REQUIREMENTS PRIOR TO THE BEGINNING Ini tia 1 Conditions:

The plant experienced a loss of all AC. BAST temperature is 153 degrees Fahrenheit.

Initiating Cues :

The plant experienced a loss of all AC. The BAST is at 153 degrees Fahrenfeit. The Shift Supervisor directs you to dilute the BAST per ER-BA. 1.

The Control Room has verified normal system alignment for steps 4.1.1 through 4.1.4, you are to begin actions at step 4.1.5. DO NOT MANIPULATE ANY EQUIPMENT.

21-Sep-2004 Job Performance Measure Exam Page:

31

Description:

Dilute BAST Following LOSS OF ALL AC (JC062.023)

JPM Tasks Task ID: 062-029-05-04B Task Standards In accordance with the procedure Tools :

Safety Glasses Hard Hat Hearing Protection Terminating Cues Task Completion

. Trainee Says Task is Completed References :

ID Description Review Date Ref Flag PRER ER-BA. 1 BAST TEMPERATURE CONCERNS - LOSS 0 OF ALL AC Safety Considerations Radiological Hazard Consequences of Inadequate Performance:

General Comments :

Radiation area entry required.

Handout COPY of ER-BA. 1.

21-Sep-2004 Page:

Job Performance Measure Exam 4 1 Performance Checklist

  • 1 Element: CRITICAL Conditions : Standards :

Locate and open MOV-826A CUE: (As each valve is Simulate depressing AND MOV-826C. manipulated) Valve no longer turns declutching device and in that direction. (Cue for valve opening valve with stem indication if examinee handwheel.

indicates observing for motion.)

CUE: (If student requests eSOMS location) eSOMS gives valve location at: AB INTERMEDIATE EAST STAIRWAY AREA. ELEV (For V-826A): 4, (For V-826C): 6.

Comments :

Satisfactory 0 Unsatisfactory 0

~~ ~ ~~~

  • 2 Element: CRITICAL Conditions : Standards :

Locate and crack open CUE: (If goes in open direction) Simulate depressing MOV-826B OR MOV-826D. Valve stem moves. declutching device and opening valve with CUE: (If student requests eSOMS handwheel.

location) eSOMS gives valve location at: AB INTERMEDIATE EAST STAIRWAY AREA, ELEV (For V-826B): 4, (For V-826D): 6 Comments :

Satisfactory Unsatisfactory 0 3 Element : Conditions : Standards :

CUE for continuation CUE:

If examinee monitors BAST overflow piping - Water flow is occurring.

If examinee contacts Control Room - RWST level has decreased by 2%.

Comments :

Satisfactory Unsatisfactory

21-Sep-2004 Page: 5 Job Performance Measure Exam

-4 Element: CRITICAL Conditions : Standards :

Close MOV-826B or MOV-826D NOTE: Order of closure for 826 Simulate using handwheel to (whichever was previously valves is not critical. close the valve that was opened). opened.

CUE: Valve no longer turns in that direction.

Comments :

Satisfactory 0 Unsatisfactory 0

~~

  • 5 Element: CRITICAL Conditions : Standards :

Close MOV-826A AND CUE: (For each valve) Valve no Simulate using handwheels to MOV-826C. longer turns in that direction. close both valves.

CUE: (If student requests eSOMS location) eSOMS gives valve location at: AB INTERMEDIATE EAST STAIRWAY AREA. ELEV (For v-826A): 4,(For V-826C): 6 CUE: No further action.

Comments :

Satisfactory n Unsatisfactory 0 JPM Questions Question Answer References Reference Type Reference ID Description Ref Flag