LCO Applicability 3.0 3.0 LIMITING CONDITION FOR OPERATION (LCO) APPLICABILITY LCO 3.0.1 LCOs shall be met during the MODES or other specified conditions in the Applicability, except as provided in LCO 3.0.2 and LCO 3.0.7.

LCO 3.0.2 Upon discovery of a failure to meet an LCO, the Required Actions of the associated Conditions shall be met, except as provided in LCO 3.0.5 and LCO 3.0.6.

If the LCO is met or is no longer applicable prior to expiration of the specified Completion Time(s), completion of the Required Action(s) is not required, unless otherwise stated.

LCO 3.0.3 When an LCO is not met and the associated ACTIONS are not met, an associated ACTION is not provided, or if directed by the associated ACTIONS, the plant shall be placed in a MODE or other specified condition in which the LCO is not applicable. Action shall be initiated within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> to place the plant, as applicable, in:

a.

MODE 3 within 7 hours8.101852e-5 days <br />0.00194 hours <br />1.157407e-5 weeks <br />2.6635e-6 months <br />;

b.

MODE 4 within 31 hours3.587963e-4 days <br />0.00861 hours <br />5.125661e-5 weeks <br />1.17955e-5 months <br />; and

c.

MODE 5 within 37 hours4.282407e-4 days <br />0.0103 hours <br />6.117725e-5 weeks <br />1.40785e-5 months <br />.

Exceptions to this Specification are stated in the individual Specifications.

Where corrective measures are completed that permit operation in accordance with the LCO or ACTIONS, completion of the actions required by LCO 3.0.3 is not required.

LCO 3.0.3 is only applicable In MODES 1, 2, 3, and 4.

LCO 3.0.4 When an LCO is not met, entry into a MODE or other specified condition in the Applicability shall only be made:

a.

When the associated ACTIONS to be entered permit continued operation In the MODE or other specified condition in the Applicability for an unlimited period of time;

b.

After performance of a risk assessment addressing inoperable systems and components, consideration of the results, determination of the acceptability of entering the MODE or other specified condition in the Applicability, and establishment of risk management actions, if appropriate; exceptions to this Specification are stated in the individual Specifications; or Palisades Nuclear Plant 3.0-1 Amendment No. 14&, 219

LCO Applicability 3.0 3.0 LCO APPLICABILITY LCO 3.0.4 (continued)

c.

When an allowance is stated in the individual value, parameter, or other Specification.

This Specification shall not prevent changes in MODES or other specified conditions in the Applicability that are required to comply with ACTIONS or that are part of a shutdown of the plant.

LCO 3.0.5 Equipment removed from service or declared inoperable to comply with ACTIONS may be returned to service under administrative control solely to perform testing required to demonstrate Its OPERABILITY or the OPERABILITY of other equipment. This is an exception to LCO 3.0.2 for the system returned to service under administrative control to perform the testing required to demonstrate OPERABILITY.

LCO 3.0.6 When a supported system LCO is not met solely due to a support system LCO not being met, the Conditions and Required Actions associated with this supported system are not required to be entered. Only the support system LCO ACTIONS are required to be entered. This is an exception to LCO 3.0.2 for the supported system. In this event, an evaluation shall be performed in accordance with Specification 5.5.13, "Safety Function Determination Program (SFDP)." If a loss of safety function is determined to exist by this program, the appropriate Conditions and Required Actions of the LCO in which the loss of safety function exists are required to be entered. When a support system's Required Action directs a supported system to be declared inoperable or directs entry into Conditions and Required Actions for a supported system, the applicable Conditions and Required Actions shall be entered in accordance with LCO 3.0.2.

LCO 3.0.7 Special Test Exception (STE) LCOs in each applicable LCO section allow specified Technical Specifications (TS) requirements to be changed to permit performance of special tests and operations. Unless otherwise specified, all other TS requirements remain unchanged. Compliance with STE LCOs is optional. When an STE LCO is desired to be met but is not met, the ACTIONS of the STE LCO shall be met. When an STE LCO is not desired to be met, entry into a MODE or other specified condition in the Applicability shall only be made in accordance with the other applicable Specifications.

I Palisades Nuclear Plant 3.0-2 Amendment No. 449g19

SR Applicability 3.0 3.0 SR APPLICABILITY SR 3.0.4 Entry into a MODE or other specified condition in the Applicability of an LCO shall only be made when the LCO's Surveillances have been met within their specified Frequency, except as provided by SR 3.0.3. When an LCO is not met due to Surveillances not having been met, entry into a MODE or other specified condition in the Applicability shall only be made in accordance with LCO 3.0.4.

This provision shall not prevent entry into MODES or other specified conditions in the Applicability that are required to comply with ACTIONS or that are part of a shutdown of the plant.

Palisades Nuclear Plant 3.0-4 Amendment No..4-,21 9

RPS Instrumentation 3.3.1 ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME C.

One Loss of Load trip unit C.1 Restore trip unit and Prior to increasing or associated instrument associated instrument THERMAL POWER channel inoperable.

channel to OPERABLE to 2 17% RTP status.

following entry into MODE 3 D.

One or more ZPM Bypass D.1 Remove the affected Immediately Removal channels ZPM Bypasses.

inoperable.

OR D.2 Declare affected trip Immediately units Inoperable.

E.


NOTE--------------

E.1 Place one trip unit in trip.

1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> Not applicable to ZPM Bypass Removal AND Function.

NOTE------------------

Not applicable to High Startup One or more Functions Rate or Loss of Load Functions.

with two RPS trip units or _

associated instrument channels inoperable.

E.2 Restore one trip unit and 7 days associated instrument channel to OPERABLE status.

F.

Two power range F.1 Restrict THERMAL 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> channels inoperable.

POWER to < 70% RTP.

Palisades Nuclear Plant 3.3.1 -2 Amendment No. 1-&, 219

ESF Instrumentation 3.3.3 3.3 INSTRUMENTATION 3.3.3 Engineered Safety Features (ESF) Instrumentation LCO 3.3.3 Four ESF bistables and associated instrument channels for each Function in Table 3.3.3-1 shall be OPERABLE.

APPLICABILITY: As specified in Table 3.3.3-1.

ACTIONS


NOTE-------------------------

Separate Condition entry is allowed for each Function.

CONDITION REQUIRED ACTION COMPLETION TIME A. --------------- NOTE A.1 Place affected bistable 7 days Not applicable to RAS.

in trip.

One or more Functions with one ESF bistable or associated instrument channel inoperable.

B. ------------NOTE-----------

B.1 Place one bistable in 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> Not applicable to RAS.

trip.

AND One or more Functions with two ESF bistables or B.2 Restore one bistable 7 days associated instrument and associated channels inoperable.

instrument channel to OPERABLE status.

I Palisades Nuclear Plant 3.3.3-1 Amendment No. 4-&, 219

PAM Instrumentation 3.3.7 3.3 INSTRUMENTATION 3.3.7 Post Accident Monitoring (PAM) Instrumentation LCO 3.3.7 APPLICABILITY:

The PAM instrumentation for each Function in Table 3.3.7-1 shall be OPERABLE.

MODES 1, 2, and 3.

ACTIONS


------------------NOTE ----

Separate Condition entry is allowed for each Function.

I CONDITION REQUIRED ACTION COMPLETION TIME A.

One or more Functions A.1 Restore required 30 days with one required channel channel to OPERABLE Inoperable.

status.

B.

Required Action and B.1 Initiate action in Immediately associated Completion accordance with Time of Condition A not Specification 5.6.6.

met.

C.

- ---------- NOTE-------------

Not applicable to hydrogen monitor channels.

One or more Functions C.1 Restore one channel to 7 days with two required channels OPERABLE status.

inoperable.

Palisades Nuclear Plant 3.3.7-1 Amendment No. 4-,219

Alternate Shutdown System 3.3.8 3.3 INSTRUMENTATION 3.3.8 Alternate Shutdown System LCO 3.3.8 The Alternate Shutdown System Functions in Table 3.3.8-1 shall be OPERABLE.

APPLICABILITY:

MODES 1, 2, and 3.

ACTIONS


NOTE-----

Separate Condition entry is allowed for each Function.

I CONDITION REQUIRED ACTION COMPLETION TIME A.

One or more required A.1 Restore required 30 days Functions inoperable.

Functions to OPERABLE status.

B.

Required Action and B.1 Be in MODE 3.

6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> associated Completion Time not met.

AND B.2 Be in MODE 4.

30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br /> Palisades Nuclear Plant 3.3.8-1 Amendment No. 4A9, 219

Pressurizer PORVs 3.4.11 3.4 PRIMARY COOLANT SYSTEM (PCS) 3.4.11 Pressurizer Power Operated Relief Valves (PORVs)

LCO 3.4.11 APPLICABILITY:

Each PORV and associated block valve shall be OPERABLE.

MODES I and 2, MODE 3 with all PCS cold leg temperatures 2 4300F.

ACTIONS


----------------------------------- N OT Separate Condition entry is allowed for each POF r-CONDITION REQUIRED ACTION COMPLETION TIME A.

One PORV inoperable.

A.1 Close associated block 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> valve.

AND A.2 Restore PORV to 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> OPERABLE status.

B. One block valve B.1 Place associated PORV 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> Inoperable.

in manual control.

AND B.2 Restore block valve to 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> OPERABLE status.

Palisades Nuclear Plant 3.4.1 1-1 Amendment No. 48-9,219

LTOP System 3.4.12 3.4 PRIMARY COOLANT SYSTEM (PCS) 3.4.12 Low Temperature Overpressure Protection (LTOP) Syst6m LCO 3.4.12 An LTOP System shall be OPERABLE with:

a.

Both High Pressure Safety Injection (HPSI) pumps incapable of injecting into the PCS, and


NOTES---------------------

1.

LCO 3.4.12.a is only required when any PCS cold leg temperature is < 3000 F.

2.

LCO 3.4.12.a does not prohibit the use of the HPSI pumps for emergency addition of makeup to the PCS.

b.

One of the following pressure relief capabilities:

1.

Two Power Operated Relief Valves (PORVs) with lift settings as specified in Figure 3.4.12-1; or

2.

The PCS depressurized and a PCS vent capable of relieving 2 167 gpm at a pressure of 315 psia.

APPLICABILITY:

MODE 3 when any PCS cold leg temperature is < 4301F, MODES 4 and 5, MODE 6 when the reactor vessel head is on.

ACTIONS NOTE-------------------

LCO 3.0.4.b is not applicable to PORVs when entering MODE 4.

I CONDITION REQUIRED ACTION COMPLETION TIME A.

One or two HPSI pumps A.1 Initiate action to verify Immediately capable of injecting into no HPSI pump is the PCS.

capable of injecting Into the PCS.

Palisades Nuclear Plant 3.4.12-1 Amendment No. 489,219

PCS Leakage Detection Instrumentation 3.4.15 3.4 PRIMARY COOLANT SYSTEM (PCS) 3.4.15 PCS Leakage Detection Instrumentation LCO 3.4.15 APPLICABILITY:

Three of the following PCS leakage detection instrumentation channels shall be OPERABLE:

a.

One containment sump level indicating channel;

b.

One containment atmosphere gaseous activity monitoring channel;

c.

One containment air cooler condensate level switch channel;

d.

One containment atmosphere humidity monitoring channel.

MODES 1, 2,3, and 4.

ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A.

One or two required leak A.1 Perform SR 3.4.13.1 Once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> detection instrument (PCS water inventory channels inoperable.

balance).

AND A.2 Restore inoperable 30 days channel(s) to OPERABLE status.

B.

Required Action and B.1 Be in MODE 3.

6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> associated Completion Time not met.

ANM B.2 Be in MODE 5.

36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br /> I

Palisades Nuclear Plant 3.4.1 5-1 Amendment No.

8-8, 219

PCS Specific Activity 3.4.16 3.4 PRIMARY COOLANT SYSTEM (PCS) 3.4.16 PCS Specific Activity LCO 3.4.16 APPLICABILITY:

The specific activity of the primary coolant shall be within limits.

MODES I and 2, MODE 3 with PCS average temperature (Tave) 2 500cF.

ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A.

DOSE EQUIVALENT 1-131


NOTE ------------------

> 1.0 pCi/gm.

LCO 3.0.4.c is applicable.

A.1 Verify DOSE Once per 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> EQUIVALENT 1-131

< 40 pCi/gm.

AND A.2 Restore DOSE 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> EQUIVALENT

-131 to within limit.

I Palisades Nuclear Plant 3.4.1 6-1 Amendment No. 4-89, 219

Hydrogen Recombiners 3.6.7 3.6 CONTAINMENT SYSTEMS 3.6.7 Hydrogen Recombiners LCO 3.6.7 APPLICABILITY:

Two hydrogen recombiners shall be OPERABLE.

MODES 1 and 2.

ACTIONS COMPLETION CONDITION REQUIRED ACTION TIME A.

One hydrogen recombiner A.1 Restore hydrogen 30 days inoperable.

recombiner to OPERABLE status.

B.

Required Action and B.1 Be in MODE 3.

6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> associated Completion Time not met.

I Palisades Nuclear Plant 3.6.7-1 Amendment No.

A-&,

219

ADVs 3.7.4 3.7 PLANT SYSTEMS 3.7.4 Atmospheric Dump Valves (ADVs)

LCO 3.7.4 APPLICABILITY:

One ADV per steam generator shall be OPERABLE.

MODES 1, 2, and 3, MODE 4 when steam generator is being relied upon for heat removal.

ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A.

One required ADV A.1 Restore ADV to 7 days inoperable.

OPERABLE status.

B. Two required ADVs B.1 Restore one ADV to 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> inoperable.

OPERABLE status.

C. Required Action and C.1 Be in MODE 3.

6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />

  • associated Completion Time not met.

AND C.2 Be in MODE 4 without 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br /> reliance upon steam generator for heat removal.

I Palisades Nuclear Plant 3.7.4-1 Amendment No. A4&,

219

AFW System 3.7.5 3.7 PLANT SYSTEMS 3.7.5 Auxiliary Feedwater (AFW) System LCO 3.7.5 Two AFW trains shall be OPERABLE.


NOTES--------------------------------------

1.

Only one AFW train, which includes a motor driven pump, is required to be OPERABLE in MODE 4.

2.

The steam driven pump is only required to be OPERABLE prior to making the reactor critical.

3.

Two AFW pumps may be placed in manual for testing, for a period of up to 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />.

APPLICABILITY:

MODES 1, 2, and 3, MODE 4 when steam generator is relied upon for heat removal.

ACTIONS

-NOTIE---- ---------------------

LCO 3.0.4.b is not applicable.

CONDITION REQUIRED ACTION COMPLETION TIME A.

One or more AFW A.1 Restore train(s) to 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> trains inoperable In OPERABLE status.

MODE 1, 2, or 3.

Palisades Nuclear Plant 3.7.5-1 Amendment No. 1449, -94, I, 219

AC Sources - Operating 3.8.1 3.8 ELECTRICAL POWER SYSTEMS 3.8.1 AC Sources - Operating LCO 3.8.1 The following AC electrical sources shall be OPERABLE:

a.

Two qualified circuits between the offsite transmission network and the onsite Class IE AC Electrical Power Distribution System; and

b.

Two Diesel Generators (DGs) each capable of supplying one train of the onsite Class 1E AC Electrical Power Distribution System.

APPLICABILITY:

MODES 1,2,3, and 4.

ACTIONS L I 1T rL-J I e!-- ------- - ------------ - -- -_-----------

LCO 3.0.4.b is not applicable to DGs.

CONDITION REQUIRED ACTION COMPLETION TIME A.

One offsite circuit A.1 Perform SR 3.8.1.1 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> inoperable.

(offsite source check) for OPERABLE offsite AND circuit.

Once per 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> AND thereafter A.2 Restore offsite circuit to 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> OPERABLE status.

AND 10 days from discovery of failure to meet LCO Palisades Nuclear Plant 3.8. 1-1 Amendment No. 4A&,

219