Morning Report Date: NOV 15, 2004 PRIORITY ATTENTION REQUIRED MORNING REPORT - REGION II Licensee/Facility:

Notification:

2-2004-0017 11/15/2004 MR Number:

CAROLINA POWER & LIGHT CO.

[1] W-3-LP, [2]

Date:

Harris Call / Fax from SRI Raleigh, North Carolina 050-00400 050-00401 Dockets:

Failure of Harris Feedwater Isolation Valve During Refueling Outage - Update

Subject:

Morning report 2-2004-0016 was issued on November 10, 2004, for a valve stem failure on the Shearon Harris C Main Feedwater (MFW) isolation valve. Subsequently, the licensee inspected all three MFW isolation valves and found damage to the seat rings on all three valves. The licensee determined that the seat ring damage was due to overtravel of the double wedge gates, on the opening stroke, which allowed the gates to travel beyond the seat rings. This resulted in contact between the gates and the top of the seat rings on the closing stroke. The overtravel of the gates was caused by insufficiently sized spacers to limit the stem travel.

The damaged seat rings were replaced on all three valves and new spacers were installed to limit the opening stroke.

The licensee performed a foreign object search and retrieval (FOSAR) inspection of the MFW piping between the isolation valves and the vertical risers inside of containment. Foreign objects with material characteristics identical to the seat rings were found in one MFW header. However, further review indicated that any foreign material of sufficient size to severely damage a steam generator tube would not be able to pass from the feed system to the steam generator.