Technical Specification Page 5.0-14 Re Steam Generator Tube Surveillance Program
ML042820564
Person / Time
Site: Diablo Canyon  
(DPR-080, DPR-082)
Issue date: 10/06/2004
From:
NRC/NRR/DLPM
To:
SHUKLA G , NRR/DLPM/PD4, 415-8420
Shared Package
ML042860206 List:
References
TAC MC1647, TAC MC1648
Download: ML042820564 (1)


Text

Programs and Manuals 5.5 5.5 Programs and Manuals 5.5.9 Steam Generator (SG) Tube Surveillance Program (continued)

(iv) Certain intersections as identified in PG&E Letter DCL-03-174, dated December 19, 2003, will be excluded from application of the voltage-based repair criteria as it is determined that these intersections may collapse or deform following a postulated LOCA + SSE event.

(v) If an unscheduled mid-cycle inspection is performed, the following mid-cycle repair limits apply instead of the limits identified in 5.5.9.d.1.j (i), 5.5.9.d.1.j (ii), and 5.5.9.d.lj (iii). The mid-cycle repair limits are determined from the following equations:

VSL VMURL (CVSL (CL-A 1.0 + NDE + Gr CL CL VMLRL = VMURL - (VURL -

VLRL) (C At)

CL where:

VURL

= upper voltage repair limit VLRL

= lower voltage repair limit VMURL = mid-cycle upper voltage repair limit based on time into cycle VMLRL = mid-cycle lower voltage repair limit based on VMURL and time into cycle At

= length of time since last scheduled inspection during which VURL and VLRL were implemented CL

= cycle length (the time between two scheduled steam generator inspections)

VSL

= structural limit voltage Gr

= average growth rate per cycle length NDE

= 95% cumulative probability allowance for nondestructive examination uncertainty (i.e., a value of 20% has been approved by the NRC)

Implementation of these mid-cycle repair limits should follow the same approach as in TS 5.5.9.d.1.j (i), 5.5.9.d.1lj (ii), and 5.5.9.d.1lj (iii).

(continued)

DIABLO CANYON - UNITS 1 & 2 5.0-14 Unit 1 -Amendment No. 435,176 8S9IDQ10.doc-RXX 16 Unit 2 -Amendment No. 435,178