September 23, 2004 LICENSEE:

Indiana Michigan Power Company FACILITY:

Donald C. Cook Nuclear Plant, Units 1 and 2

SUBJECT:

SUMMARY

OF TELEPHONE CONFERENCE HELD ON SEPTEMBER 7, 2004, BETWEEN THE U.S. NUCLEAR REGULATORY COMMISSION AND INDIANA MICHIGAN POWER COMPANY, CONCERNING FOLLOW-UP ITEMS TO REQUESTS FOR ADDITIONAL INFORMATION PERTAINING TO THE DONALD C. COOK NUCLEAR PLANT, UNITS 1 AND 2, LICENSE RENEWAL APPLICATION The U.S. Nuclear Regulatory Commission staff (the staff) and representatives of Indiana Michigan Power Company (I&M) held a telephone conference on September 7, 2004, to discuss and clarify follow-up items to requests for additional information (RAIs) concerning the Donald C. Cook Nuclear Plant, Units 1 and 2, license renewal application (LRA). The conference call was useful in clarifying the intent of the follow-up items. provides a listing of the telephone conference participants. Enclosure 2 contains a listing of the items discussed with the applicant, including a brief description on the status of the items.

The applicant has had an opportunity to comment on this summary.

/RA/

Jonathan G. Rowley, Project Manager License Renewal Section A License Renewal and Environmental Impacts Program Division of Regulatory Improvement Programs Office of Nuclear Reactor Regulation Docket Nos.: 50-315 and 50-316

Enclosures:

As stated cc w/encls: See next page

ML042790484 DOCUMENT NAME: C:\\ORPCheckout\\FileNET\\ML042790484.wpd OFFICE PM:RLEP LA:RLEP SC:RLEP NAME JRowley MJenkins SLee DATE 9/234 9/22/04 9/23/04

DISTRIBUTION: Licensee: Indiana Michigan Power Co., Re: Donald C.Cook Plant, Units 1 and 2, Dated: September 23, 2004 Accession No: ML042790484 HARD COPY RLEP RF J. Rowley (PM)

E-MAIL:

RidsNrrDrip RidsNrrDe G. Bagchi K. Manoly W. Bateman J. Calvo R. Jenkins P. Shemanski J. Fair RidsNrrDssa RidsNrrDipm D. Thatcher R. Pettis C. Li M. Itzkowitz (RidsOgcMailCenter)

R. Weisman M. Mayfield A. Murphy S. Smith (srs3)

S. Duraiswamy Y. L. (Renee) Li RLEP Staff R. Gramm A. Howell J. Stang J. Strasma, RIII M. Kotzalas OPA NRR/ADPT secretary (RidsNrrAdpt)

LIST OF PARTICIPANTS FOR TELEPHONE CONFERENCE TO DISCUSS THE DONALD C. COOK NUCLEAR PLANT, UNITS 1 AND 2 LICENSE RENEWAL APPLICATION SEPTEMBER 7, 2004 Participants Affiliations Jonathan Rowley U.S. Nuclear Regulatory Commission (NRC)

Hansraj Ashar NRC Neil Haggerty Indiana Michigan Power Company (I&M)

Bob Kalinowski I&M FOLLOW-UP ITEMS DONALD C. COOK NUCLEAR PLANT, UNITS 1 AND 2 LICENSE RENEWAL APPLICATION SEPTEMBER 7, 2004 The U.S. Nuclear Regulatory Commission staff (the staff) and representatives of Indiana Michigan Power Company (I&M) held a telephone conference call on September 7, 2004, to discuss and clarify follow-up items to RAIs concerning the Donald C. Cook Nuclear Plant, Units 1 and 2 (Cook), license renewal application (LRA). The following Items were discussed during the telephone conference call.

1. Follow-up Item to RAI 3.5-1 How many penetration bellows are in the Cook containments? Please summarize the operating experience related to the examination of these bellows. If provisions are made to assess their leaktightness (as they are not accessible for visual examination), please provide a summary of these provisions (including frequency of tests), and indicate if such leaktightness assessment of the bellows is part of the LRA aging management program (AMP) B.1.15 or B.1.8.

Staff Request I&Ms original response to RAI 3.5-1 indicates that the Cook containments do not have any containment pressure-boundary bellows. I&M is requested to confirm.

Status: The staff indicated to the applicant that the original response appeared contradictory to Table 3.5.2-1 of the LRA. Following an evaluation of the staffs position, the applicant stated that the response will be clarified. The applicant will submit a revised response.

2. Follow-up Item to RAI 3.5-2 For seals and gaskets related to containment penetrations, in Item Number 3.5.1-6 of the LRA, containment in-service inspection (ISI) and containment leak rate testing have been stated as the aging management programs. For equipment hatches and air-locks at Cook, the staff agrees with the applicant's assertion that the leak rate testing program will monitor aging degradation of their seals and gaskets, as they are leak rate tested after each closing. For other penetrations with seals and gaskets, the applicant is requested to provide information regarding the adequacy of Type B leak rate testing frequency to monitor aging degradation of seals and gaskets at Cook.

Staff Request Item II A3.3-a (Page II A3-5) of NUREG-1801 addresses the aging management of seals, gaskets, etc., which are part of the containment pressure boundary, i.e. seals and gaskets of equipment hatches, and mechanical & electrical penetrations. If I&M plans to monitor only air lock seals by means of containment leakage rate testing, then the applicant is requested to provide additional information regarding the aging management of seals and gaskets of equipment hatches, and mechanical and electrical penetration associated with the containment pressure boundary. If I&M credits containment leak rate testing program (Type B test of Appendix J) for aging management of these seals and gaskets, the applicant is requested to provide additional information as requested in RAI 3.5-2.

Status: The applicant indicated that the question is clear. The applicant will submit a revised response.

Donald C. Cook Nuclear Plant, Units 1 and 2 cc:

Regional Administrator, Region III U.S. Nuclear Regulatory Commission 2443 Warrenville Road, Suite 210 Lisle, IL 60532-4351 Township Supervisor Lake Township Hall P.O. Box 818 Bridgman, MI 49106 U.S. Nuclear Regulatory Commission Resident Inspectors Office 7700 Red Arrow Highway Stevensville, MI 49127 David W. Jenkins, Esquire Indiana Michigan Power Company One Cook Place Bridgman, MI 49106 Mayor, City of Bridgman P.O. Box 366 Bridgman, MI 49106 Special Assistant to the Governor Room 1 - State Capitol Lansing, MI 48909 Mr. John A. Zwolinski Director, Design Engineering and Regulatory Affairs Indiana Michigan Power Company Nuclear Generation Group 500 Circle Drive Buchanan, MI 49107 Michigan Department of Environmental Quality Waste and Hazardous Materials Div.

Hazardous Waste & Radiological Protection Section Nuclear Facilities Unit Constitution Hall, Lower-Level North 525 West Allegan Street P.O. Box 30241 Lansing, MI 48909-7741 Michael J. Finissi, Plant Manager Indiana Michigan Power Company Nuclear Generation Group One Cook Place Bridgman, MI 49106 Mr. Joseph N. Jensen, Site Vice President Indiana Michigan Power Company Nuclear Generation Group One Cook Place Bridgman, MI 49106 Mr. Fred Emerson Nuclear Energy Institute 1776 I Street, N.W., Suite 400 Washington, DC 20006-3708 Richard J. Grumbir Project Manager, License Renewal Indiana Michigan Power Company Nuclear Generation Group 500 Circle Drive Buchanan, MI 49107 Laura Kozak 2443 Warrenville Rd.