b Dominion October 4, 2004 United States Nuclear Regulatory Commission Serial No.04-608 Attention: Document Control Desk NL&OS/ETS RO Washington, D.C. 20555 Docket No. 50-338 License No. NPF-4 VIRGINIA ELECTRIC AND POWER COMPANY NORTH ANNA POWER STATION UNIT 1 STEAM GENERATOR TUBE PLUGGING REPORT Scheduled eddy current inspections of the North Anna Unit 1 C steam generator were completed during the Fall 2004 Refueling Outage. In accordance with North Anna Power Station Technical Specifications, Reporting Requirement 5.6.7.a, this letter provides notification of a steam generator tube that was plugged during the outage.
The tube was damaged by a foreign object and had an indication of damage that exceeds the North Anna Technical Specification plugging limit of 40 percent through wall. The indication was found by Bobbin Probe Examination in tube SGC R37 C79. A loose part was also noted at the time of inspection and subsequently removed. The tube was then tested with a rotating pancake coil for sizing. Using three different approved sizing techniques resulted in the following assessments with the most conservative being 43 percent through wall.
Technique No.
Depth (TW)
Ci rcu mfe renti al Axial ETSS 9691 0 ETSS 9691 1 ETSS 21 998 18%
30%
43%
0.41 0.41 0.44 0.14 0.14 0.1 6 Bobbin coil and rotating pancake coil inspection of potentially affected surrounding tubes revealed no additional damage.
Should you have any questions or require additional information, please contact Mr. Thomas Shaub at (804) 273-2763.
Very truly yours, ---
C. L. Funderburk, Director Nuclear Licensing and Operations Support Dominion Resources Services, Inc.
for Virginia Electric and Power Company No new commitments are intended by this letter.
cc:
U.S. Nuclear Regulatory Commission Region II Sam Nunn Atlanta Federal Center 61 Forsyth Street, SW Suite 23T85 Atlanta, Georgia 30303 Mr. Stephen R. Monarque NRC Project Manager - Surry and North Anna U. S. Nuclear Regulatory Commission One White Flint North 1 1555 Rockville Pike Mail Stop 8-HI2 Rockville, Maryland 20852 Mr. J. E. Reasor, Jr.