Text
Appendices 129
Appendix A - Description of Davis-Besse Monte Carlo Damage-State Code The Davis-Besse Monte Carlo Damage-State computer code was developed for this study to provide estimates of the LOCA probabilities as a function of time throughout the estimated history of the wastage cavity. Figure A1 presents a flowchart of the basic structure of the code, where in Step MC1 the case conditions are setup by the user through a sequence of prompts as shown in Figs. A2 upon startup of the code.
130
Fig. A1. Flowchart for Davis-Besse Monte Carlo Damage State code.
131
(a)
(b)
Fig. A2. Davis-Besse Monte Carlo Damage State Code prompts for input to setup case conditions:
(a) sampling distributions for cavity wastage and flaw growth rates, (b) cavity growth/shape, LOCA screening/binning rules, and fixed As-Found (CCA) or uncertain As-Found (ASP) 132
(c)
(d)
Fig. A2. (continued) Davis-Besse Monte Carlo Damage State Code prompts for input to setup case conditions: (c) As-Found fixed damage state, correlated distribution for plastic flow properties, A-tip ductile tearing treatment, scaling of J-integral driving forces, and (d) number of Monte Carlo realizations.
133
(a)
(b)
Fig. A3. The output file DB_MONTE_Case.out includes (a) a listing of the input conditions of the case and a time stamp to record the beginning of the execution and (b) the resulting binning data for each antithetic variates pass.
134
Appendix B - Listing of CCA and ASP Time Integration Results Case CCA-001 represents the best-estimate case for the CCA study.
A-Tip A-Tip As-Found Sampling Scale Sampling Distributions Sampling Cavity LOCA Case Ductile Instability Atip Depth of Plastic Driving dR /d da /d Distribution Growth Binning Number Tearing Tested? (in) Flow Props. Forces (in/yr) (in/month) Group Rules Rules CCA-001 Yes Yes 0.0650 bivariate lognormal Yes beta-1 Weibull BE BE BE Case Matrix for the ASP Study A-Tip A-Tip Sampling Scale Cavity LOCA Case Ductile Instability of Plastic Driving dR/d da/d R0 flaw-ini Sampling Growth Binning Number Tearing Tested? Flow Props. Forces (in/yr) (in/month) (in) (months) Distributions Rules Rules ASP-001 Yes Yes bivariate lognormal Yes beta-1 Weibull beta Weibull BE BE BE ASP-002 Yes Yes bivariate lognormal Yes beta-1 Weibull beta Weibull BE BE LC ASP-003 Yes Yes bivariate lognormal Yes beta-1 Weibull beta Weibull BE BE MC ASP-004 Yes Yes bivariate lognormal Yes beta-1 Weibull beta Weibull BE LC BE ASP-005 Yes Yes bivariate lognormal Yes beta-1 Weibull beta Weibull BE LC LC ASP-006 Yes Yes bivariate lognormal Yes beta-1 Weibull beta Weibull BE LC MC ASP-007 Yes Yes bivariate lognormal Yes beta-1 Weibull beta Weibull BE MC BE ASP-008 Yes Yes bivariate lognormal Yes beta-1 Weibull beta Weibull BE MC LC ASP-009 Yes Yes bivariate lognormal Yes beta-1 Weibull beta Weibull BE MC MC 135
Table B1. LOCA Probability History for CCA-01 Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA for Days After TOD 50 99.30% 0.71% 0.71% 0.00% 0.00%
51 99.22% 0.78% 0.78% 0.00% 0.00%
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 52 99.11% 0.89% 0.89% 0.00% 0.00%
-365 100.00% 0.00% 0.00% 0.00% 0.00%
53 99.03% 0.97% 0.97% 0.00% 0.00%
1 100.00% 0.00% 0.00% 0.00% 0.00%
54 98.96% 1.05% 1.05% 0.00% 0.00%
2 100.00% 0.00% 0.00% 0.00% 0.00%
55 98.87% 1.13% 1.13% 0.00% 0.00%
3 100.00% 0.00% 0.00% 0.00% 0.00%
56 98.77% 1.23% 1.23% 0.00% 0.00%
4 100.00% 0.00% 0.00% 0.00% 0.00%
57 98.66% 1.34% 1.34% 0.00% 0.00%
5 100.00% 0.00% 0.00% 0.00% 0.00%
58 98.56% 1.44% 1.44% 0.00% 0.00%
6 100.00% 0.00% 0.00% 0.00% 0.00%
59 98.45% 1.55% 1.55% 0.00% 0.00%
7 100.00% 0.00% 0.00% 0.00% 0.00%
60 98.34% 1.66% 1.66% 0.00% 0.00%
8 100.00% 0.00% 0.00% 0.00% 0.00%
61 98.20% 1.80% 1.80% 0.00% 0.00%
9 100.00% 0.00% 0.00% 0.00% 0.00%
62 98.06% 1.94% 1.94% 0.00% 0.00%
10 100.00% 0.00% 0.00% 0.00% 0.00%
63 97.93% 2.07% 2.07% 0.00% 0.00%
11 100.00% 0.00% 0.00% 0.00% 0.00%
64 97.80% 2.20% 2.20% 0.00% 0.00%
12 100.00% 0.00% 0.00% 0.00% 0.00%
65 97.65% 2.35% 2.35% 0.00% 0.00%
13 100.00% 0.00% 0.00% 0.00% 0.00%
66 97.49% 2.51% 2.51% 0.00% 0.00%
14 100.00% 0.00% 0.00% 0.00% 0.00%
67 97.33% 2.67% 2.67% 0.00% 0.00%
15 100.00% 0.00% 0.00% 0.00% 0.00%
68 97.17% 2.84% 2.84% 0.00% 0.00%
16 100.00% 0.00% 0.00% 0.00% 0.00%
69 96.99% 3.01% 3.01% 0.00% 0.00%
17 100.00% 0.00% 0.00% 0.00% 0.00%
70 96.81% 3.19% 3.19% 0.00% 0.00%
18 100.00% 0.00% 0.00% 0.00% 0.00%
71 96.61% 3.39% 3.39% 0.00% 0.00%
19 100.00% 0.00% 0.00% 0.00% 0.00%
72 96.42% 3.58% 3.58% 0.00% 0.00%
20 100.00% 0.00% 0.00% 0.00% 0.00%
73 96.21% 3.79% 3.79% 0.00% 0.00%
21 100.00% 0.00% 0.00% 0.00% 0.00%
74 96.02% 3.98% 3.98% 0.00% 0.00%
22 100.00% 0.00% 0.00% 0.00% 0.00%
75 95.84% 4.17% 4.16% 0.00% 0.00%
23 100.00% 0.00% 0.00% 0.00% 0.00%
76 95.65% 4.35% 4.35% 0.00% 0.00%
24 100.00% 0.00% 0.00% 0.00% 0.00%
77 95.44% 4.56% 4.56% 0.00% 0.00%
25 100.00% 0.00% 0.00% 0.00% 0.00%
78 95.22% 4.78% 4.78% 0.00% 0.00%
26 100.00% 0.00% 0.00% 0.00% 0.00%
79 94.99% 5.01% 5.01% 0.00% 0.00%
27 100.00% 0.00% 0.00% 0.00% 0.00%
80 94.78% 5.22% 5.22% 0.00% 0.00%
28 100.00% 0.00% 0.00% 0.00% 0.00%
81 94.53% 5.47% 5.47% 0.00% 0.00%
29 99.99% 0.01% 0.01% 0.00% 0.00%
82 94.30% 5.70% 5.70% 0.00% 0.00%
30 99.99% 0.02% 0.02% 0.00% 0.00%
83 94.08% 5.92% 5.92% 0.00% 0.00%
31 99.98% 0.03% 0.03% 0.00% 0.00%
84 93.86% 6.14% 6.14% 0.00% 0.00%
32 99.97% 0.03% 0.03% 0.00% 0.00%
85 93.63% 6.38% 6.37% 0.00% 0.00%
33 99.96% 0.04% 0.04% 0.00% 0.00%
86 93.38% 6.62% 6.62% 0.00% 0.00%
34 99.95% 0.05% 0.05% 0.00% 0.00%
87 93.13% 6.87% 6.87% 0.01% 0.00%
35 99.93% 0.07% 0.07% 0.00% 0.00%
88 92.87% 7.14% 7.13% 0.01% 0.00%
36 99.91% 0.09% 0.09% 0.00% 0.00%
89 92.60% 7.40% 7.39% 0.01% 0.00%
37 99.89% 0.11% 0.11% 0.00% 0.00%
90 92.36% 7.65% 7.63% 0.01% 0.00%
38 99.87% 0.13% 0.13% 0.00% 0.00%
91 92.08% 7.92% 7.90% 0.02% 0.00%
39 99.85% 0.16% 0.16% 0.00% 0.00%
92 91.82% 8.18% 8.17% 0.02% 0.00%
40 99.82% 0.18% 0.18% 0.00% 0.00%
93 91.52% 8.48% 8.46% 0.02% 0.00%
41 99.78% 0.22% 0.22% 0.00% 0.00%
94 91.20% 8.80% 8.77% 0.03% 0.00%
42 99.76% 0.24% 0.24% 0.00% 0.00%
95 90.92% 9.08% 9.05% 0.03% 0.00%
43 99.72% 0.28% 0.28% 0.00% 0.00%
96 90.64% 9.36% 9.33% 0.03% 0.00%
44 99.66% 0.34% 0.34% 0.00% 0.00%
97 90.37% 9.63% 9.59% 0.04% 0.00%
45 99.63% 0.38% 0.38% 0.00% 0.00%
98 90.07% 9.93% 9.89% 0.05% 0.00%
46 99.57% 0.43% 0.43% 0.00% 0.00%
99 89.75% 10.25% 10.20% 0.05% 0.00%
47 99.51% 0.49% 0.49% 0.00% 0.00%
100 89.46% 10.54% 10.49% 0.05% 0.00%
48 99.45% 0.55% 0.55% 0.00% 0.00%
101 89.14% 10.86% 10.80% 0.06% 0.00%
49 99.39% 0.61% 0.61% 0.00% 0.00%
136
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 102 88.83% 11.17% 11.11% 0.06% 0.00% 154 71.31% 28.70% 27.44% 1.18% 0.08%
103 88.50% 11.50% 11.43% 0.07% 0.00% 155 70.98% 29.02% 27.73% 1.21% 0.08%
104 88.20% 11.80% 11.72% 0.08% 0.00% 156 70.64% 29.36% 28.05% 1.23% 0.08%
105 87.89% 12.11% 12.02% 0.09% 0.00% 157 70.29% 29.71% 28.36% 1.26% 0.09%
106 87.59% 12.41% 12.31% 0.09% 0.00% 158 69.96% 30.04% 28.67% 1.28% 0.09%
107 87.28% 12.72% 12.62% 0.11% 0.00% 159 69.63% 30.37% 28.97% 1.31% 0.09%
108 86.97% 13.03% 12.92% 0.12% 0.00% 160 69.31% 30.69% 29.25% 1.35% 0.09%
109 86.64% 13.36% 13.24% 0.13% 0.00% 161 69.02% 30.98% 29.51% 1.37% 0.10%
110 86.30% 13.70% 13.56% 0.14% 0.00% 162 68.68% 31.32% 29.81% 1.40% 0.10%
111 85.97% 14.03% 13.88% 0.15% 0.00% 163 68.36% 31.64% 30.10% 1.44% 0.10%
112 85.64% 14.36% 14.20% 0.16% 0.00% 164 68.06% 31.94% 30.37% 1.46% 0.11%
113 85.29% 14.71% 14.53% 0.18% 0.00% 165 67.75% 32.26% 30.65% 1.49% 0.11%
114 84.94% 15.07% 14.87% 0.19% 0.00% 166 67.41% 32.59% 30.96% 1.52% 0.11%
115 84.60% 15.40% 15.19% 0.21% 0.00% 167 67.08% 32.92% 31.24% 1.56% 0.12%
116 84.26% 15.74% 15.52% 0.22% 0.00% 168 66.78% 33.22% 31.50% 1.60% 0.12%
117 83.91% 16.09% 15.84% 0.24% 0.00% 169 66.48% 33.52% 31.78% 1.62% 0.13%
118 83.57% 16.43% 16.17% 0.26% 0.00% 170 66.18% 33.82% 32.04% 1.65% 0.13%
119 83.22% 16.78% 16.50% 0.28% 0.00% 171 65.89% 34.11% 32.29% 1.69% 0.13%
120 82.89% 17.11% 16.80% 0.31% 0.00% 172 65.58% 34.42% 32.56% 1.72% 0.14%
121 82.51% 17.49% 17.16% 0.33% 0.00% 173 65.28% 34.72% 32.84% 1.75% 0.14%
122 82.14% 17.86% 17.51% 0.35% 0.00% 174 64.94% 35.06% 33.14% 1.78% 0.14%
123 81.81% 18.19% 17.82% 0.38% 0.00% 175 64.62% 35.38% 33.43% 1.81% 0.15%
124 81.46% 18.54% 18.15% 0.39% 0.00% 176 64.32% 35.69% 33.69% 1.84% 0.15%
125 81.12% 18.88% 18.47% 0.41% 0.00% 177 64.02% 35.98% 33.95% 1.87% 0.16%
126 80.77% 19.23% 18.79% 0.44% 0.00% 178 63.75% 36.25% 34.19% 1.90% 0.16%
127 80.42% 19.59% 19.12% 0.46% 0.01% 179 63.45% 36.55% 34.47% 1.93% 0.16%
128 80.09% 19.91% 19.43% 0.48% 0.01% 180 63.13% 36.87% 34.75% 1.96% 0.17%
129 79.76% 20.24% 19.73% 0.50% 0.01% 181 62.83% 37.17% 35.00% 2.00% 0.17%
130 79.41% 20.59% 20.05% 0.53% 0.01% 182 62.51% 37.50% 35.29% 2.03% 0.17%
131 79.07% 20.93% 20.38% 0.54% 0.01% 183 62.22% 37.78% 35.55% 2.05% 0.18%
132 78.73% 21.27% 20.70% 0.57% 0.01% 184 61.92% 38.08% 35.81% 2.09% 0.18%
133 78.40% 21.60% 21.00% 0.59% 0.01% 185 61.64% 38.36% 36.05% 2.12% 0.19%
134 78.06% 21.94% 21.32% 0.61% 0.01% 186 61.37% 38.63% 36.30% 2.14% 0.19%
135 77.73% 22.27% 21.62% 0.64% 0.01% 187 61.08% 38.92% 36.56% 2.16% 0.20%
136 77.38% 22.62% 21.94% 0.67% 0.02% 188 60.79% 39.21% 36.82% 2.19% 0.20%
137 77.05% 22.96% 22.25% 0.69% 0.02% 189 60.52% 39.48% 37.06% 2.22% 0.21%
138 76.70% 23.30% 22.56% 0.72% 0.02% 190 60.25% 39.75% 37.30% 2.24% 0.21%
139 76.34% 23.66% 22.89% 0.75% 0.02% 191 59.97% 40.04% 37.55% 2.27% 0.22%
140 76.02% 23.98% 23.18% 0.78% 0.02% 192 59.69% 40.31% 37.80% 2.29% 0.22%
141 75.69% 24.31% 23.49% 0.80% 0.02% 193 59.40% 40.60% 38.06% 2.32% 0.22%
142 75.36% 24.65% 23.78% 0.84% 0.03% 194 59.13% 40.87% 38.30% 2.35% 0.22%
143 75.01% 24.99% 24.09% 0.87% 0.03% 195 58.88% 41.12% 38.52% 2.37% 0.23%
144 74.67% 25.33% 24.40% 0.89% 0.04% 196 58.64% 41.36% 38.75% 2.39% 0.23%
145 74.37% 25.64% 24.68% 0.92% 0.04% 197 58.36% 41.64% 38.99% 2.41% 0.23%
146 73.98% 26.02% 25.03% 0.95% 0.04% 198 58.11% 41.89% 39.22% 2.43% 0.24%
147 73.64% 26.37% 25.35% 0.97% 0.05% 199 57.86% 42.14% 39.45% 2.45% 0.24%
148 73.30% 26.70% 25.65% 1.00% 0.05% 200 57.59% 42.41% 39.70% 2.47% 0.25%
149 72.96% 27.04% 25.95% 1.03% 0.06% 201 57.32% 42.68% 39.94% 2.49% 0.25%
150 72.64% 27.36% 26.24% 1.06% 0.06% 202 57.06% 42.94% 40.17% 2.52% 0.25%
151 72.29% 27.71% 26.55% 1.10% 0.07% 203 56.82% 43.18% 40.38% 2.55% 0.26%
152 71.98% 28.02% 26.83% 1.12% 0.07% 204 56.56% 43.44% 40.61% 2.57% 0.26%
153 71.63% 28.37% 27.14% 1.15% 0.07% 205 56.31% 43.69% 40.84% 2.59% 0.26%
137
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 206 56.03% 43.98% 41.09% 2.62% 0.27% 258 44.57% 55.43% 51.32% 3.68% 0.43%
207 55.79% 44.21% 41.30% 2.64% 0.27% 259 44.38% 55.62% 51.48% 3.70% 0.44%
208 55.54% 44.46% 41.53% 2.67% 0.27% 260 44.21% 55.79% 51.64% 3.72% 0.44%
209 55.32% 44.68% 41.72% 2.68% 0.28% 261 44.00% 56.00% 51.83% 3.73% 0.44%
210 55.08% 44.92% 41.93% 2.70% 0.28% 262 43.81% 56.19% 51.99% 3.75% 0.44%
211 54.86% 45.14% 42.13% 2.72% 0.28% 263 43.65% 56.35% 52.13% 3.77% 0.45%
212 54.60% 45.40% 42.37% 2.75% 0.29% 264 43.50% 56.50% 52.27% 3.78% 0.45%
213 54.38% 45.62% 42.57% 2.77% 0.29% 265 43.34% 56.66% 52.41% 3.80% 0.45%
214 54.11% 45.89% 42.81% 2.79% 0.30% 266 43.18% 56.82% 52.55% 3.81% 0.46%
215 53.90% 46.10% 43.00% 2.80% 0.30% 267 43.00% 57.00% 52.70% 3.84% 0.46%
216 53.66% 46.34% 43.22% 2.82% 0.30% 268 42.83% 57.17% 52.85% 3.86% 0.47%
217 53.42% 46.58% 43.42% 2.85% 0.31% 269 42.64% 57.36% 53.02% 3.87% 0.47%
218 53.21% 46.79% 43.61% 2.87% 0.31% 270 42.46% 57.54% 53.19% 3.88% 0.47%
219 52.97% 47.03% 43.82% 2.89% 0.31% 271 42.28% 57.73% 53.35% 3.90% 0.47%
220 52.74% 47.26% 44.02% 2.92% 0.32% 272 42.09% 57.91% 53.50% 3.93% 0.48%
221 52.52% 47.48% 44.22% 2.93% 0.32% 273 41.93% 58.07% 53.64% 3.95% 0.48%
222 52.30% 47.70% 44.42% 2.95% 0.33% 274 41.75% 58.25% 53.80% 3.97% 0.48%
223 52.05% 47.95% 44.65% 2.97% 0.33% 275 41.58% 58.42% 53.95% 3.99% 0.48%
224 51.84% 48.17% 44.83% 3.00% 0.34% 276 41.40% 58.60% 54.11% 4.00% 0.49%
225 51.62% 48.38% 45.03% 3.01% 0.34% 277 41.22% 58.78% 54.27% 4.02% 0.49%
226 51.40% 48.60% 45.23% 3.03% 0.34% 278 41.05% 58.95% 54.42% 4.04% 0.49%
227 51.15% 48.85% 45.44% 3.06% 0.34% 279 40.89% 59.12% 54.57% 4.05% 0.50%
228 50.90% 49.10% 45.67% 3.09% 0.35% 280 40.71% 59.29% 54.73% 4.06% 0.50%
229 50.66% 49.34% 45.88% 3.11% 0.35% 281 40.53% 59.47% 54.89% 4.09% 0.50%
230 50.40% 49.60% 46.12% 3.13% 0.35% 282 40.36% 59.65% 55.03% 4.11% 0.50%
231 50.19% 49.81% 46.31% 3.15% 0.35% 283 40.18% 59.82% 55.19% 4.13% 0.50%
232 49.96% 50.04% 46.52% 3.17% 0.36% 284 40.00% 60.00% 55.35% 4.15% 0.51%
233 49.75% 50.25% 46.70% 3.20% 0.36% 285 39.83% 60.17% 55.50% 4.16% 0.51%
234 49.52% 50.48% 46.91% 3.21% 0.36% 286 39.67% 60.33% 55.65% 4.18% 0.51%
235 49.31% 50.69% 47.10% 3.22% 0.37% 287 39.49% 60.52% 55.82% 4.19% 0.51%
236 49.12% 50.88% 47.27% 3.24% 0.37% 288 39.33% 60.67% 55.95% 4.20% 0.52%
237 48.91% 51.09% 47.46% 3.26% 0.37% 289 39.18% 60.82% 56.09% 4.21% 0.52%
238 48.70% 51.30% 47.65% 3.27% 0.38% 290 39.02% 60.98% 56.23% 4.23% 0.52%
239 48.47% 51.53% 47.86% 3.29% 0.38% 291 38.85% 61.15% 56.39% 4.23% 0.52%
240 48.25% 51.75% 48.06% 3.31% 0.39% 292 38.68% 61.32% 56.54% 4.25% 0.53%
241 48.05% 51.95% 48.24% 3.32% 0.39% 293 38.53% 61.47% 56.67% 4.27% 0.53%
242 47.83% 52.18% 48.44% 3.35% 0.39% 294 38.37% 61.63% 56.80% 4.29% 0.53%
243 47.58% 52.42% 48.66% 3.37% 0.39% 295 38.20% 61.80% 56.95% 4.31% 0.54%
244 47.39% 52.62% 48.83% 3.39% 0.40% 296 38.06% 61.94% 57.08% 4.32% 0.54%
245 47.20% 52.80% 49.00% 3.41% 0.40% 297 37.89% 62.11% 57.23% 4.34% 0.54%
246 47.00% 53.00% 49.18% 3.43% 0.40% 298 37.76% 62.25% 57.35% 4.36% 0.54%
247 46.79% 53.22% 49.36% 3.45% 0.40% 299 37.61% 62.39% 57.48% 4.37% 0.54%
248 46.56% 53.44% 49.56% 3.48% 0.41% 300 37.46% 62.54% 57.61% 4.38% 0.55%
249 46.36% 53.64% 49.73% 3.49% 0.41% 301 37.30% 62.70% 57.76% 4.39% 0.55%
250 46.14% 53.86% 49.93% 3.51% 0.42% 302 37.18% 62.82% 57.87% 4.40% 0.55%
251 45.96% 54.04% 50.10% 3.53% 0.42% 303 37.01% 62.99% 58.01% 4.43% 0.55%
252 45.78% 54.22% 50.26% 3.54% 0.42% 304 36.85% 63.15% 58.15% 4.44% 0.55%
253 45.57% 54.43% 50.44% 3.57% 0.42% 305 36.71% 63.29% 58.28% 4.46% 0.56%
254 45.37% 54.63% 50.62% 3.59% 0.42% 306 36.57% 63.43% 58.40% 4.47% 0.56%
255 45.17% 54.83% 50.79% 3.62% 0.42% 307 36.44% 63.56% 58.52% 4.48% 0.56%
256 44.96% 55.04% 50.97% 3.64% 0.43% 308 36.31% 63.69% 58.63% 4.50% 0.56%
257 44.77% 55.24% 51.15% 3.66% 0.43% 309 36.15% 63.85% 58.77% 4.52% 0.57%
138
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 310 36.03% 63.97% 58.88% 4.53% 0.57% 362 29.51% 70.49% 64.64% 5.16% 0.69%
311 35.88% 64.12% 59.01% 4.54% 0.57% 363 29.43% 70.58% 64.72% 5.17% 0.69%
312 35.75% 64.25% 59.13% 4.55% 0.57% 364 29.32% 70.68% 64.82% 5.18% 0.69%
313 35.61% 64.39% 59.25% 4.57% 0.57% 365 29.22% 70.78% 64.91% 5.19% 0.69%
314 35.48% 64.52% 59.37% 4.58% 0.58% 366 29.11% 70.89% 65.00% 5.20% 0.69%
315 35.33% 64.67% 59.49% 4.59% 0.58% 367 29.01% 70.99% 65.09% 5.21% 0.69%
316 35.20% 64.80% 59.61% 4.61% 0.58% 368 28.91% 71.09% 65.18% 5.22% 0.69%
317 35.08% 64.92% 59.72% 4.62% 0.59% 369 28.80% 71.20% 65.28% 5.23% 0.69%
318 34.94% 65.06% 59.84% 4.63% 0.59% 370 28.69% 71.31% 65.38% 5.23% 0.69%
319 34.80% 65.20% 59.96% 4.65% 0.59% 371 28.59% 71.41% 65.47% 5.24% 0.70%
320 34.68% 65.32% 60.06% 4.67% 0.59% 372 28.49% 71.51% 65.57% 5.25% 0.70%
321 34.56% 65.44% 60.17% 4.68% 0.59% 373 28.39% 71.61% 65.65% 5.26% 0.70%
322 34.42% 65.58% 60.29% 4.70% 0.60% 374 28.28% 71.72% 65.74% 5.28% 0.70%
323 34.30% 65.70% 60.39% 4.71% 0.60% 375 28.18% 71.82% 65.84% 5.28% 0.70%
324 34.16% 65.84% 60.51% 4.73% 0.60% 376 28.07% 71.93% 65.93% 5.29% 0.71%
325 34.04% 65.97% 60.62% 4.74% 0.60% 377 27.98% 72.02% 66.02% 5.30% 0.71%
326 33.90% 66.10% 60.75% 4.75% 0.60% 378 27.89% 72.11% 66.10% 5.30% 0.71%
327 33.78% 66.22% 60.85% 4.77% 0.61% 379 27.79% 72.21% 66.19% 5.31% 0.71%
328 33.65% 66.35% 60.96% 4.78% 0.61% 380 27.70% 72.30% 66.27% 5.32% 0.71%
329 33.52% 66.48% 61.07% 4.79% 0.62% 381 27.60% 72.40% 66.36% 5.32% 0.71%
330 33.38% 66.62% 61.20% 4.80% 0.62% 382 27.50% 72.50% 66.45% 5.33% 0.71%
331 33.24% 66.76% 61.33% 4.82% 0.62% 383 27.42% 72.58% 66.53% 5.34% 0.72%
332 33.12% 66.88% 61.43% 4.83% 0.62% 384 27.32% 72.68% 66.61% 5.35% 0.72%
333 33.01% 66.99% 61.53% 4.84% 0.63% 385 27.23% 72.77% 66.70% 5.36% 0.72%
334 32.88% 67.12% 61.65% 4.85% 0.63% 386 27.13% 72.87% 66.78% 5.37% 0.72%
335 32.75% 67.25% 61.76% 4.86% 0.63% 387 27.04% 72.96% 66.87% 5.37% 0.72%
336 32.62% 67.38% 61.87% 4.87% 0.63% 388 26.94% 73.06% 66.96% 5.38% 0.72%
337 32.51% 67.49% 61.97% 4.88% 0.64% 389 26.83% 73.17% 67.06% 5.39% 0.72%
338 32.38% 67.62% 62.08% 4.90% 0.64% 390 26.75% 73.25% 67.13% 5.40% 0.72%
339 32.24% 67.76% 62.21% 4.91% 0.64% 391 26.66% 73.34% 67.21% 5.40% 0.72%
340 32.12% 67.88% 62.31% 4.92% 0.64% 392 26.57% 73.44% 67.30% 5.41% 0.73%
341 32.02% 67.98% 62.41% 4.93% 0.64% 393 26.47% 73.53% 67.39% 5.42% 0.73%
342 31.89% 68.11% 62.53% 4.94% 0.64% 394 26.37% 73.63% 67.47% 5.43% 0.73%
343 31.78% 68.22% 62.62% 4.95% 0.65% 395 26.28% 73.72% 67.55% 5.44% 0.73%
344 31.66% 68.34% 62.74% 4.96% 0.65% 396 26.18% 73.82% 67.64% 5.45% 0.73%
345 31.54% 68.46% 62.85% 4.96% 0.65% 397 26.10% 73.90% 67.70% 5.47% 0.73%
346 31.42% 68.58% 62.96% 4.97% 0.65% 398 26.02% 73.98% 67.78% 5.47% 0.73%
347 31.30% 68.70% 63.06% 4.99% 0.65% 399 25.93% 74.08% 67.86% 5.48% 0.73%
348 31.17% 68.84% 63.18% 5.00% 0.66% 400 25.83% 74.17% 67.95% 5.49% 0.73%
349 31.04% 68.96% 63.29% 5.01% 0.66% 401 25.74% 74.26% 68.03% 5.50% 0.73%
350 30.94% 69.06% 63.38% 5.02% 0.66% 402 25.65% 74.35% 68.10% 5.51% 0.73%
351 30.83% 69.17% 63.48% 5.03% 0.66% 403 25.55% 74.45% 68.20% 5.52% 0.74%
352 30.71% 69.30% 63.58% 5.05% 0.67% 404 25.45% 74.55% 68.29% 5.53% 0.74%
353 30.58% 69.42% 63.69% 5.07% 0.67% 405 25.36% 74.64% 68.36% 5.54% 0.74%
354 30.46% 69.54% 63.80% 5.08% 0.67% 406 25.25% 74.75% 68.46% 5.55% 0.74%
355 30.33% 69.67% 63.92% 5.09% 0.67% 407 25.17% 74.83% 68.53% 5.56% 0.74%
356 30.20% 69.80% 64.03% 5.10% 0.67% 408 25.07% 74.93% 68.61% 5.57% 0.74%
357 30.08% 69.92% 64.14% 5.11% 0.67% 409 24.99% 75.01% 68.69% 5.58% 0.74%
358 29.96% 70.04% 64.24% 5.12% 0.67% 410 24.90% 75.10% 68.77% 5.59% 0.74%
359 29.84% 70.16% 64.35% 5.14% 0.68% 411 24.83% 75.17% 68.83% 5.60% 0.75%
360 29.73% 70.27% 64.45% 5.15% 0.68% 412 24.74% 75.26% 68.91% 5.60% 0.75%
361 29.62% 70.38% 64.54% 5.16% 0.68% 413 24.65% 75.35% 68.99% 5.61% 0.75%
139
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 414 24.56% 75.44% 69.07% 5.62% 0.75% 466 20.59% 79.42% 72.63% 5.97% 0.81%
415 24.49% 75.51% 69.13% 5.63% 0.75% 467 20.51% 79.49% 72.69% 5.98% 0.81%
416 24.39% 75.61% 69.22% 5.63% 0.75% 468 20.44% 79.56% 72.76% 5.99% 0.81%
417 24.30% 75.70% 69.30% 5.64% 0.76% 469 20.38% 79.62% 72.81% 6.00% 0.81%
418 24.22% 75.78% 69.38% 5.65% 0.76% 470 20.32% 79.68% 72.87% 6.00% 0.81%
419 24.15% 75.85% 69.44% 5.65% 0.76% 471 20.25% 79.75% 72.93% 6.01% 0.81%
420 24.06% 75.94% 69.51% 5.67% 0.76% 472 20.18% 79.82% 72.99% 6.01% 0.81%
421 23.99% 76.01% 69.58% 5.67% 0.76% 473 20.12% 79.88% 73.05% 6.02% 0.81%
422 23.91% 76.09% 69.65% 5.68% 0.76% 474 20.05% 79.95% 73.11% 6.03% 0.82%
423 23.81% 76.19% 69.73% 5.69% 0.76% 475 19.98% 80.02% 73.17% 6.03% 0.82%
424 23.73% 76.27% 69.81% 5.70% 0.76% 476 19.92% 80.08% 73.23% 6.04% 0.82%
425 23.65% 76.35% 69.89% 5.70% 0.76% 477 19.87% 80.13% 73.27% 6.04% 0.82%
426 23.57% 76.43% 69.96% 5.71% 0.77% 478 19.81% 80.20% 73.33% 6.04% 0.82%
427 23.49% 76.51% 70.03% 5.71% 0.77% 479 19.74% 80.26% 73.39% 6.05% 0.82%
428 23.40% 76.60% 70.11% 5.72% 0.77% 480 19.68% 80.32% 73.45% 6.05% 0.83%
429 23.31% 76.69% 70.19% 5.73% 0.77% 481 19.62% 80.38% 73.50% 6.05% 0.83%
430 23.24% 76.76% 70.25% 5.74% 0.77% 482 19.55% 80.45% 73.57% 6.06% 0.83%
431 23.14% 76.86% 70.34% 5.75% 0.77% 483 19.48% 80.52% 73.62% 6.07% 0.83%
432 23.05% 76.96% 70.43% 5.76% 0.77% 484 19.41% 80.59% 73.68% 6.08% 0.83%
433 22.98% 77.02% 70.48% 5.76% 0.77% 485 19.35% 80.65% 73.73% 6.09% 0.83%
434 22.90% 77.10% 70.56% 5.77% 0.78% 486 19.29% 80.71% 73.79% 6.09% 0.83%
435 22.82% 77.18% 70.63% 5.78% 0.78% 487 19.24% 80.76% 73.84% 6.09% 0.83%
436 22.75% 77.25% 70.69% 5.79% 0.78% 488 19.19% 80.82% 73.88% 6.10% 0.83%
437 22.67% 77.33% 70.76% 5.80% 0.78% 489 19.11% 80.89% 73.94% 6.11% 0.84%
438 22.59% 77.41% 70.84% 5.80% 0.78% 490 19.04% 80.96% 74.00% 6.12% 0.84%
439 22.52% 77.48% 70.90% 5.80% 0.78% 491 18.98% 81.02% 74.06% 6.12% 0.84%
440 22.44% 77.56% 70.97% 5.81% 0.78% 492 18.92% 81.08% 74.11% 6.13% 0.84%
441 22.37% 77.63% 71.04% 5.81% 0.78% 493 18.86% 81.14% 74.16% 6.14% 0.84%
442 22.30% 77.70% 71.10% 5.82% 0.78% 494 18.81% 81.20% 74.22% 6.14% 0.84%
443 22.22% 77.78% 71.17% 5.83% 0.78% 495 18.74% 81.26% 74.27% 6.15% 0.84%
444 22.14% 77.86% 71.24% 5.84% 0.78% 496 18.66% 81.34% 74.35% 6.15% 0.84%
445 22.07% 77.93% 71.31% 5.84% 0.79% 497 18.61% 81.40% 74.40% 6.15% 0.84%
446 21.99% 78.01% 71.38% 5.85% 0.79% 498 18.54% 81.46% 74.46% 6.16% 0.84%
447 21.92% 78.08% 71.44% 5.85% 0.79% 499 18.48% 81.52% 74.52% 6.16% 0.84%
448 21.84% 78.16% 71.51% 5.86% 0.79% 500 18.42% 81.59% 74.57% 6.17% 0.84%
449 21.76% 78.25% 71.59% 5.87% 0.79% 501 18.35% 81.65% 74.63% 6.17% 0.85%
450 21.68% 78.32% 71.66% 5.87% 0.79% 502 18.28% 81.72% 74.70% 6.18% 0.85%
451 21.60% 78.40% 71.72% 5.88% 0.79% 503 18.22% 81.78% 74.75% 6.19% 0.85%
452 21.53% 78.47% 71.79% 5.89% 0.79% 504 18.16% 81.84% 74.80% 6.19% 0.85%
453 21.46% 78.54% 71.86% 5.89% 0.79% 505 18.09% 81.91% 74.86% 6.20% 0.85%
454 21.39% 78.61% 71.91% 5.91% 0.80% 506 18.02% 81.99% 74.93% 6.20% 0.85%
455 21.32% 78.69% 71.98% 5.91% 0.80% 507 17.96% 82.04% 74.98% 6.21% 0.85%
456 21.25% 78.75% 72.03% 5.92% 0.80% 508 17.91% 82.09% 75.03% 6.21% 0.85%
457 21.18% 78.82% 72.09% 5.93% 0.80% 509 17.84% 82.16% 75.09% 6.22% 0.85%
458 21.10% 78.90% 72.16% 5.93% 0.80% 510 17.79% 82.21% 75.14% 6.22% 0.85%
459 21.05% 78.96% 72.21% 5.94% 0.80% 511 17.72% 82.28% 75.20% 6.23% 0.85%
460 20.97% 79.03% 72.29% 5.94% 0.81% 512 17.67% 82.33% 75.24% 6.23% 0.86%
461 20.92% 79.09% 72.33% 5.95% 0.81% 513 17.60% 82.40% 75.30% 6.24% 0.86%
462 20.86% 79.14% 72.38% 5.95% 0.81% 514 17.55% 82.45% 75.34% 6.25% 0.86%
463 20.80% 79.21% 72.44% 5.96% 0.81% 515 17.49% 82.51% 75.40% 6.26% 0.86%
464 20.73% 79.27% 72.50% 5.96% 0.81% 516 17.43% 82.57% 75.45% 6.26% 0.86%
465 20.67% 79.33% 72.55% 5.97% 0.81% 517 17.38% 82.62% 75.50% 6.26% 0.86%
140
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 518 17.32% 82.68% 75.55% 6.27% 0.86% 570 14.75% 85.25% 77.83% 6.52% 0.90%
519 17.26% 82.74% 75.60% 6.27% 0.87% 571 14.71% 85.30% 77.88% 6.52% 0.90%
520 17.21% 82.79% 75.65% 6.28% 0.87% 572 14.66% 85.34% 77.92% 6.52% 0.90%
521 17.15% 82.85% 75.70% 6.29% 0.87% 573 14.62% 85.38% 77.96% 6.53% 0.90%
522 17.10% 82.90% 75.75% 6.29% 0.87% 574 14.57% 85.43% 78.00% 6.53% 0.90%
523 17.04% 82.96% 75.80% 6.30% 0.87% 575 14.54% 85.46% 78.03% 6.53% 0.90%
524 16.98% 83.02% 75.85% 6.30% 0.87% 576 14.50% 85.50% 78.06% 6.54% 0.90%
525 16.93% 83.07% 75.89% 6.30% 0.87% 577 14.45% 85.55% 78.10% 6.54% 0.90%
526 16.89% 83.12% 75.94% 6.31% 0.87% 578 14.41% 85.60% 78.15% 6.54% 0.90%
527 16.83% 83.17% 75.99% 6.31% 0.87% 579 14.35% 85.65% 78.19% 6.55% 0.91%
528 16.78% 83.22% 76.03% 6.32% 0.87% 580 14.31% 85.69% 78.23% 6.55% 0.91%
529 16.73% 83.27% 76.08% 6.32% 0.87% 581 14.26% 85.74% 78.28% 6.56% 0.91%
530 16.67% 83.33% 76.14% 6.33% 0.87% 582 14.23% 85.77% 78.31% 6.56% 0.91%
531 16.62% 83.38% 76.19% 6.33% 0.87% 583 14.18% 85.82% 78.35% 6.57% 0.91%
532 16.56% 83.44% 76.24% 6.33% 0.87% 584 14.13% 85.87% 78.39% 6.57% 0.91%
533 16.51% 83.49% 76.28% 6.34% 0.87% 585 14.09% 85.91% 78.43% 6.57% 0.91%
534 16.45% 83.55% 76.33% 6.35% 0.87% 586 14.05% 85.95% 78.47% 6.57% 0.91%
535 16.39% 83.61% 76.39% 6.35% 0.87% 587 13.99% 86.01% 78.52% 6.58% 0.91%
536 16.35% 83.65% 76.42% 6.36% 0.87% 588 13.95% 86.05% 78.56% 6.58% 0.91%
537 16.29% 83.71% 76.47% 6.36% 0.87% 589 13.92% 86.08% 78.59% 6.59% 0.91%
538 16.25% 83.75% 76.51% 6.37% 0.88% 590 13.87% 86.13% 78.62% 6.59% 0.91%
539 16.20% 83.80% 76.55% 6.37% 0.88% 591 13.83% 86.17% 78.66% 6.60% 0.91%
540 16.16% 83.84% 76.59% 6.38% 0.88% 592 13.79% 86.21% 78.70% 6.60% 0.91%
541 16.12% 83.88% 76.62% 6.38% 0.88% 593 13.76% 86.24% 78.73% 6.60% 0.91%
542 16.07% 83.93% 76.67% 6.38% 0.88% 594 13.72% 86.28% 78.76% 6.61% 0.91%
543 16.02% 83.98% 76.71% 6.39% 0.88% 595 13.69% 86.32% 78.79% 6.61% 0.92%
544 15.98% 84.03% 76.75% 6.39% 0.88% 596 13.65% 86.35% 78.83% 6.61% 0.92%
545 15.91% 84.09% 76.81% 6.40% 0.88% 597 13.61% 86.40% 78.86% 6.62% 0.92%
546 15.88% 84.13% 76.84% 6.41% 0.88% 598 13.57% 86.43% 78.89% 6.63% 0.92%
547 15.82% 84.18% 76.89% 6.41% 0.88% 599 13.52% 86.48% 78.93% 6.63% 0.92%
548 15.78% 84.22% 76.92% 6.42% 0.88% 600 13.49% 86.51% 78.97% 6.63% 0.92%
549 15.74% 84.26% 76.96% 6.42% 0.88% 601 13.43% 86.57% 79.02% 6.64% 0.92%
550 15.68% 84.32% 77.01% 6.43% 0.88% 602 13.39% 86.62% 79.06% 6.64% 0.92%
551 15.64% 84.37% 77.05% 6.43% 0.88% 603 13.35% 86.65% 79.09% 6.64% 0.92%
552 15.58% 84.42% 77.10% 6.44% 0.88% 604 13.31% 86.69% 79.13% 6.65% 0.92%
553 15.52% 84.48% 77.15% 6.44% 0.89% 605 13.27% 86.73% 79.16% 6.65% 0.92%
554 15.47% 84.53% 77.20% 6.45% 0.89% 606 13.23% 86.77% 79.20% 6.66% 0.92%
555 15.43% 84.57% 77.23% 6.45% 0.89% 607 13.20% 86.80% 79.23% 6.66% 0.92%
556 15.40% 84.61% 77.27% 6.45% 0.89% 608 13.17% 86.83% 79.25% 6.66% 0.92%
557 15.34% 84.66% 77.31% 6.46% 0.89% 609 13.13% 86.87% 79.29% 6.67% 0.92%
558 15.30% 84.70% 77.35% 6.47% 0.89% 610 13.09% 86.92% 79.33% 6.67% 0.92%
559 15.25% 84.75% 77.39% 6.47% 0.89% 611 13.03% 86.97% 79.37% 6.67% 0.92%
560 15.21% 84.79% 77.42% 6.48% 0.89% 612 13.00% 87.00% 79.40% 6.68% 0.92%
561 15.17% 84.83% 77.46% 6.48% 0.89% 613 12.96% 87.04% 79.44% 6.68% 0.92%
562 15.11% 84.89% 77.51% 6.49% 0.89% 614 12.93% 87.07% 79.47% 6.68% 0.92%
563 15.08% 84.92% 77.54% 6.49% 0.89% 615 12.89% 87.11% 79.50% 6.68% 0.93%
564 15.04% 84.97% 77.58% 6.50% 0.90% 616 12.85% 87.15% 79.54% 6.69% 0.93%
565 14.98% 85.02% 77.63% 6.50% 0.90% 617 12.82% 87.18% 79.57% 6.69% 0.93%
566 14.93% 85.08% 77.68% 6.50% 0.90% 618 12.79% 87.21% 79.59% 6.69% 0.93%
567 14.88% 85.12% 77.72% 6.50% 0.90% 619 12.75% 87.25% 79.63% 6.69% 0.93%
568 14.84% 85.16% 77.75% 6.51% 0.90% 620 12.72% 87.28% 79.66% 6.70% 0.93%
569 14.79% 85.21% 77.80% 6.52% 0.90% 621 12.68% 87.32% 79.69% 6.70% 0.93%
141
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 622 12.64% 87.36% 79.73% 6.71% 0.93% 674 11.01% 88.99% 81.17% 6.88% 0.94%
623 12.60% 87.40% 79.76% 6.71% 0.93% 675 10.97% 89.03% 81.20% 6.89% 0.94%
624 12.56% 87.44% 79.80% 6.72% 0.93% 676 10.94% 89.06% 81.23% 6.89% 0.94%
625 12.53% 87.47% 79.82% 6.72% 0.93% 677 10.90% 89.10% 81.26% 6.90% 0.94%
626 12.49% 87.51% 79.86% 6.72% 0.93% 678 10.88% 89.12% 81.28% 6.90% 0.95%
627 12.47% 87.54% 79.88% 6.73% 0.93% 679 10.84% 89.16% 81.31% 6.90% 0.95%
628 12.43% 87.57% 79.91% 6.73% 0.93% 680 10.83% 89.18% 81.33% 6.90% 0.95%
629 12.40% 87.60% 79.94% 6.74% 0.93% 681 10.81% 89.20% 81.34% 6.90% 0.95%
630 12.37% 87.64% 79.97% 6.74% 0.93% 682 10.78% 89.22% 81.37% 6.91% 0.95%
631 12.34% 87.66% 79.99% 6.74% 0.93% 683 10.74% 89.26% 81.40% 6.91% 0.95%
632 12.28% 87.72% 80.04% 6.75% 0.93% 684 10.71% 89.29% 81.43% 6.92% 0.95%
633 12.25% 87.75% 80.07% 6.75% 0.93% 685 10.67% 89.33% 81.46% 6.92% 0.95%
634 12.21% 87.79% 80.09% 6.76% 0.93% 686 10.66% 89.35% 81.47% 6.92% 0.95%
635 12.18% 87.82% 80.12% 6.77% 0.93% 687 10.62% 89.38% 81.50% 6.92% 0.95%
636 12.14% 87.86% 80.16% 6.77% 0.93% 688 10.59% 89.41% 81.53% 6.93% 0.95%
637 12.11% 87.89% 80.18% 6.77% 0.94% 689 10.57% 89.44% 81.55% 6.93% 0.95%
638 12.08% 87.92% 80.21% 6.78% 0.94% 690 10.53% 89.47% 81.58% 6.93% 0.95%
639 12.05% 87.95% 80.24% 6.78% 0.94% 691 10.50% 89.50% 81.61% 6.94% 0.96%
640 12.02% 87.98% 80.26% 6.79% 0.94% 692 10.47% 89.53% 81.64% 6.94% 0.96%
641 11.99% 88.01% 80.28% 6.79% 0.94% 693 10.42% 89.58% 81.68% 6.94% 0.96%
642 11.95% 88.05% 80.32% 6.79% 0.94% 694 10.40% 89.60% 81.70% 6.95% 0.96%
643 11.92% 88.08% 80.35% 6.80% 0.94% 695 10.38% 89.62% 81.71% 6.95% 0.96%
644 11.89% 88.11% 80.36% 6.81% 0.94% 696 10.35% 89.65% 81.74% 6.95% 0.96%
645 11.86% 88.14% 80.39% 6.81% 0.94% 697 10.33% 89.67% 81.76% 6.96% 0.96%
646 11.83% 88.17% 80.43% 6.81% 0.94% 698 10.30% 89.71% 81.78% 6.97% 0.96%
647 11.80% 88.20% 80.45% 6.81% 0.94% 699 10.27% 89.73% 81.80% 6.97% 0.96%
648 11.76% 88.24% 80.49% 6.81% 0.94% 700 10.25% 89.75% 81.82% 6.97% 0.96%
649 11.73% 88.27% 80.52% 6.82% 0.94% 701 10.23% 89.78% 81.84% 6.97% 0.96%
650 11.70% 88.30% 80.54% 6.82% 0.94% 702 10.20% 89.80% 81.86% 6.98% 0.96%
651 11.67% 88.33% 80.57% 6.82% 0.94% 703 10.16% 89.84% 81.89% 6.98% 0.96%
652 11.64% 88.36% 80.60% 6.82% 0.94% 704 10.13% 89.87% 81.92% 6.99% 0.96%
653 11.62% 88.38% 80.61% 6.82% 0.94% 705 10.10% 89.90% 81.95% 6.99% 0.96%
654 11.60% 88.40% 80.64% 6.83% 0.94% 706 10.07% 89.93% 81.98% 6.99% 0.96%
655 11.57% 88.43% 80.66% 6.83% 0.94% 707 10.05% 89.95% 82.00% 6.99% 0.97%
656 11.54% 88.46% 80.68% 6.83% 0.94% 708 10.02% 89.98% 82.02% 7.00% 0.97%
657 11.52% 88.48% 80.71% 6.84% 0.94% 709 9.99% 90.01% 82.04% 7.00% 0.97%
658 11.49% 88.51% 80.74% 6.84% 0.94% 710 9.96% 90.04% 82.07% 7.01% 0.97%
659 11.45% 88.55% 80.76% 6.84% 0.94% 711 9.94% 90.06% 82.09% 7.01% 0.97%
660 11.43% 88.58% 80.79% 6.84% 0.94% 712 9.92% 90.09% 82.11% 7.01% 0.97%
661 11.40% 88.60% 80.82% 6.85% 0.94% 713 9.90% 90.10% 82.13% 7.01% 0.97%
662 11.36% 88.64% 80.85% 6.85% 0.94% 714 9.87% 90.13% 82.15% 7.02% 0.97%
663 11.32% 88.68% 80.88% 6.86% 0.94% 715 9.85% 90.15% 82.17% 7.02% 0.97%
664 11.29% 88.71% 80.91% 6.86% 0.94% 716 9.82% 90.18% 82.19% 7.02% 0.97%
665 11.26% 88.74% 80.94% 6.86% 0.94% 717 9.80% 90.21% 82.21% 7.03% 0.97%
666 11.23% 88.77% 80.97% 6.86% 0.94% 718 9.77% 90.23% 82.24% 7.03% 0.97%
667 11.21% 88.79% 80.98% 6.86% 0.94% 719 9.74% 90.26% 82.26% 7.03% 0.97%
668 11.18% 88.82% 81.01% 6.87% 0.94% 720 9.72% 90.28% 82.27% 7.03% 0.97%
669 11.16% 88.84% 81.03% 6.87% 0.94% 721 9.70% 90.30% 82.29% 7.04% 0.97%
670 11.13% 88.87% 81.06% 6.87% 0.94% 722 9.68% 90.32% 82.31% 7.04% 0.97%
671 11.11% 88.89% 81.08% 6.87% 0.94% 723 9.66% 90.34% 82.32% 7.04% 0.98%
672 11.07% 88.93% 81.12% 6.88% 0.94% 724 9.65% 90.35% 82.33% 7.05% 0.98%
673 11.04% 88.96% 81.14% 6.88% 0.94% 725 9.62% 90.38% 82.36% 7.05% 0.98%
142
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 726 9.59% 90.41% 82.38% 7.05% 0.98% 778 8.33% 91.67% 83.49% 7.17% 1.01%
727 9.56% 90.44% 82.41% 7.06% 0.98% 779 8.31% 91.69% 83.51% 7.17% 1.01%
728 9.54% 90.46% 82.42% 7.06% 0.98% 780 8.29% 91.71% 83.53% 7.18% 1.01%
729 9.52% 90.48% 82.44% 7.06% 0.98% 781 8.27% 91.73% 83.55% 7.18% 1.01%
730 9.49% 90.51% 82.47% 7.06% 0.98% 782 8.25% 91.75% 83.57% 7.18% 1.01%
731 9.46% 90.54% 82.50% 7.06% 0.98% 783 8.22% 91.78% 83.59% 7.18% 1.01%
732 9.44% 90.56% 82.52% 7.06% 0.98% 784 8.20% 91.80% 83.61% 7.18% 1.01%
733 9.42% 90.58% 82.54% 7.06% 0.98% 785 8.18% 91.82% 83.63% 7.19% 1.01%
734 9.40% 90.60% 82.56% 7.06% 0.98% 786 8.16% 91.84% 83.64% 7.19% 1.01%
735 9.37% 90.63% 82.58% 7.07% 0.98% 787 8.14% 91.87% 83.67% 7.19% 1.01%
736 9.35% 90.65% 82.60% 7.07% 0.98% 788 8.12% 91.88% 83.68% 7.19% 1.01%
737 9.32% 90.68% 82.62% 7.07% 0.98% 789 8.09% 91.91% 83.71% 7.19% 1.01%
738 9.29% 90.71% 82.65% 7.08% 0.98% 790 8.07% 91.93% 83.72% 7.20% 1.01%
739 9.27% 90.73% 82.67% 7.08% 0.98% 791 8.05% 91.95% 83.74% 7.20% 1.01%
740 9.25% 90.75% 82.69% 7.08% 0.98% 792 8.03% 91.97% 83.76% 7.20% 1.01%
741 9.22% 90.78% 82.71% 7.08% 0.99% 793 8.01% 91.99% 83.78% 7.20% 1.01%
742 9.20% 90.80% 82.73% 7.09% 0.99% 794 7.99% 92.01% 83.80% 7.20% 1.01%
743 9.17% 90.83% 82.76% 7.09% 0.99% 795 7.97% 92.03% 83.81% 7.21% 1.01%
744 9.15% 90.86% 82.78% 7.09% 0.99% 796 7.95% 92.05% 83.83% 7.21% 1.01%
745 9.12% 90.89% 82.80% 7.10% 0.99% 797 7.93% 92.07% 83.85% 7.21% 1.01%
746 9.10% 90.90% 82.82% 7.10% 0.99% 798 7.91% 92.09% 83.86% 7.21% 1.01%
747 9.08% 90.93% 82.84% 7.10% 0.99% 799 7.89% 92.11% 83.88% 7.22% 1.01%
748 9.05% 90.95% 82.86% 7.10% 0.99% 800 7.88% 92.13% 83.89% 7.22% 1.01%
749 9.02% 90.98% 82.89% 7.10% 0.99% 801 7.85% 92.15% 83.92% 7.22% 1.01%
750 8.99% 91.01% 82.91% 7.11% 0.99% 802 7.83% 92.17% 83.93% 7.22% 1.02%
751 8.98% 91.03% 82.93% 7.11% 0.99% 803 7.81% 92.19% 83.95% 7.23% 1.02%
752 8.95% 91.05% 82.95% 7.11% 0.99% 804 7.80% 92.21% 83.96% 7.23% 1.02%
753 8.93% 91.07% 82.96% 7.11% 0.99% 805 7.78% 92.22% 83.97% 7.23% 1.02%
754 8.91% 91.09% 82.98% 7.11% 0.99% 806 7.76% 92.24% 83.99% 7.23% 1.02%
755 8.89% 91.11% 83.00% 7.12% 0.99% 807 7.74% 92.26% 84.01% 7.24% 1.02%
756 8.87% 91.13% 83.02% 7.12% 0.99% 808 7.72% 92.28% 84.03% 7.24% 1.02%
757 8.85% 91.15% 83.03% 7.12% 0.99% 809 7.70% 92.30% 84.04% 7.25% 1.02%
758 8.82% 91.18% 83.06% 7.13% 0.99% 810 7.67% 92.33% 84.06% 7.25% 1.02%
759 8.80% 91.20% 83.08% 7.13% 0.99% 811 7.65% 92.35% 84.08% 7.25% 1.02%
760 8.78% 91.22% 83.09% 7.13% 0.99% 812 7.63% 92.37% 84.10% 7.25% 1.02%
761 8.76% 91.24% 83.11% 7.13% 0.99% 813 7.61% 92.39% 84.12% 7.25% 1.02%
762 8.74% 91.26% 83.14% 7.14% 0.99% 814 7.60% 92.41% 84.13% 7.26% 1.02%
763 8.71% 91.29% 83.16% 7.14% 0.99% 815 7.58% 92.42% 84.15% 7.26% 1.02%
764 8.68% 91.32% 83.19% 7.14% 1.00% 816 7.56% 92.44% 84.16% 7.26% 1.02%
765 8.66% 91.34% 83.21% 7.14% 1.00% 817 7.54% 92.46% 84.18% 7.27% 1.02%
766 8.64% 91.37% 83.23% 7.14% 1.00% 818 7.53% 92.47% 84.19% 7.27% 1.02%
767 8.60% 91.40% 83.26% 7.14% 1.00% 819 7.51% 92.49% 84.20% 7.27% 1.02%
768 8.58% 91.42% 83.28% 7.14% 1.00% 820 7.49% 92.51% 84.22% 7.27% 1.02%
769 8.56% 91.45% 83.30% 7.15% 1.00% 821 7.46% 92.54% 84.25% 7.27% 1.02%
770 8.53% 91.47% 83.32% 7.15% 1.00% 822 7.44% 92.56% 84.26% 7.28% 1.02%
771 8.51% 91.50% 83.35% 7.15% 1.00% 823 7.42% 92.58% 84.29% 7.28% 1.02%
772 8.49% 91.51% 83.36% 7.15% 1.00% 824 7.40% 92.60% 84.30% 7.28% 1.02%
773 8.45% 91.55% 83.39% 7.15% 1.00% 825 7.38% 92.62% 84.32% 7.28% 1.02%
774 8.43% 91.57% 83.42% 7.16% 1.00% 826 7.37% 92.63% 84.33% 7.28% 1.02%
775 8.40% 91.60% 83.44% 7.16% 1.00% 827 7.35% 92.65% 84.35% 7.28% 1.02%
776 8.38% 91.62% 83.46% 7.16% 1.00% 828 7.33% 92.67% 84.36% 7.29% 1.02%
777 8.36% 91.65% 83.48% 7.17% 1.00% 829 7.32% 92.68% 84.37% 7.29% 1.02%
143
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 830 7.30% 92.70% 84.38% 7.30% 1.02% 882 6.38% 93.62% 85.18% 7.40% 1.04%
831 7.29% 92.71% 84.39% 7.30% 1.02% 883 6.37% 93.64% 85.19% 7.40% 1.04%
832 7.26% 92.74% 84.41% 7.30% 1.02% 884 6.35% 93.65% 85.21% 7.41% 1.04%
833 7.24% 92.76% 84.43% 7.30% 1.03% 885 6.34% 93.67% 85.22% 7.41% 1.04%
834 7.22% 92.78% 84.45% 7.31% 1.03% 886 6.32% 93.68% 85.23% 7.41% 1.04%
835 7.21% 92.79% 84.46% 7.31% 1.03% 887 6.30% 93.70% 85.25% 7.41% 1.04%
836 7.19% 92.81% 84.48% 7.31% 1.03% 888 6.29% 93.71% 85.26% 7.41% 1.04%
837 7.17% 92.83% 84.49% 7.32% 1.03% 889 6.28% 93.72% 85.27% 7.41% 1.04%
838 7.16% 92.85% 84.50% 7.32% 1.03% 890 6.27% 93.73% 85.28% 7.41% 1.04%
839 7.13% 92.87% 84.53% 7.32% 1.03% 891 6.26% 93.75% 85.29% 7.41% 1.04%
840 7.12% 92.88% 84.54% 7.32% 1.03% 892 6.24% 93.76% 85.30% 7.41% 1.04%
841 7.10% 92.90% 84.55% 7.32% 1.03% 893 6.22% 93.78% 85.32% 7.42% 1.04%
842 7.08% 92.92% 84.57% 7.32% 1.03% 894 6.21% 93.80% 85.34% 7.42% 1.04%
843 7.07% 92.94% 84.59% 7.32% 1.03% 895 6.19% 93.81% 85.35% 7.42% 1.04%
844 7.04% 92.96% 84.61% 7.33% 1.03% 896 6.18% 93.83% 85.36% 7.42% 1.04%
845 7.03% 92.98% 84.62% 7.33% 1.03% 897 6.15% 93.85% 85.39% 7.42% 1.04%
846 7.01% 92.99% 84.63% 7.33% 1.03% 898 6.13% 93.87% 85.40% 7.42% 1.04%
847 6.99% 93.02% 84.66% 7.33% 1.03% 899 6.12% 93.88% 85.41% 7.42% 1.04%
848 6.96% 93.04% 84.67% 7.33% 1.03% 900 6.11% 93.89% 85.42% 7.43% 1.04%
849 6.94% 93.06% 84.69% 7.34% 1.03% 901 6.10% 93.90% 85.43% 7.43% 1.04%
850 6.92% 93.08% 84.71% 7.34% 1.03% 902 6.08% 93.92% 85.45% 7.43% 1.05%
851 6.90% 93.10% 84.73% 7.34% 1.03% 903 6.06% 93.94% 85.46% 7.43% 1.05%
852 6.88% 93.12% 84.75% 7.35% 1.03% 904 6.05% 93.95% 85.48% 7.43% 1.05%
853 6.85% 93.15% 84.77% 7.35% 1.03% 905 6.04% 93.96% 85.49% 7.43% 1.05%
854 6.84% 93.17% 84.79% 7.35% 1.03% 906 6.02% 93.98% 85.50% 7.43% 1.05%
855 6.82% 93.18% 84.80% 7.35% 1.03% 907 6.01% 93.99% 85.52% 7.43% 1.05%
856 6.81% 93.19% 84.82% 7.35% 1.03% 908 6.00% 94.00% 85.52% 7.44% 1.05%
857 6.78% 93.22% 84.83% 7.36% 1.03% 909 5.99% 94.02% 85.53% 7.44% 1.05%
858 6.76% 93.24% 84.85% 7.36% 1.03% 910 5.98% 94.02% 85.54% 7.44% 1.05%
859 6.74% 93.26% 84.87% 7.36% 1.03% 911 5.96% 94.04% 85.55% 7.44% 1.05%
860 6.73% 93.28% 84.88% 7.36% 1.03% 912 5.95% 94.05% 85.56% 7.44% 1.05%
861 6.71% 93.30% 84.90% 7.37% 1.03% 913 5.93% 94.07% 85.58% 7.44% 1.05%
862 6.69% 93.31% 84.91% 7.37% 1.03% 914 5.92% 94.08% 85.59% 7.45% 1.05%
863 6.67% 93.33% 84.93% 7.37% 1.03% 915 5.91% 94.09% 85.60% 7.45% 1.05%
864 6.66% 93.34% 84.94% 7.37% 1.03% 916 5.90% 94.10% 85.61% 7.45% 1.05%
865 6.64% 93.36% 84.96% 7.37% 1.04% 917 5.88% 94.12% 85.62% 7.45% 1.05%
866 6.63% 93.37% 84.97% 7.37% 1.04% 918 5.86% 94.14% 85.64% 7.45% 1.05%
867 6.61% 93.40% 84.98% 7.38% 1.04% 919 5.85% 94.15% 85.65% 7.45% 1.05%
868 6.59% 93.41% 85.00% 7.38% 1.04% 920 5.84% 94.16% 85.66% 7.46% 1.05%
869 6.57% 93.43% 85.01% 7.38% 1.04% 921 5.83% 94.17% 85.67% 7.46% 1.05%
870 6.56% 93.45% 85.03% 7.38% 1.04% 922 5.81% 94.19% 85.68% 7.46% 1.05%
871 6.55% 93.45% 85.03% 7.39% 1.04% 923 5.80% 94.20% 85.69% 7.46% 1.05%
872 6.53% 93.47% 85.04% 7.39% 1.04% 924 5.79% 94.21% 85.70% 7.46% 1.05%
873 6.51% 93.49% 85.06% 7.39% 1.04% 925 5.78% 94.22% 85.71% 7.46% 1.05%
874 6.50% 93.50% 85.07% 7.39% 1.04% 926 5.77% 94.24% 85.72% 7.46% 1.05%
875 6.48% 93.52% 85.09% 7.39% 1.04% 927 5.75% 94.25% 85.73% 7.46% 1.05%
876 6.47% 93.53% 85.10% 7.39% 1.04% 928 5.74% 94.26% 85.75% 7.46% 1.05%
877 6.46% 93.54% 85.11% 7.39% 1.04% 929 5.73% 94.27% 85.76% 7.47% 1.05%
878 6.45% 93.55% 85.12% 7.39% 1.04% 930 5.71% 94.29% 85.78% 7.47% 1.05%
879 6.43% 93.57% 85.14% 7.40% 1.04% 931 5.69% 94.31% 85.79% 7.47% 1.05%
880 6.41% 93.59% 85.15% 7.40% 1.04% 932 5.68% 94.32% 85.80% 7.47% 1.05%
881 6.40% 93.60% 85.16% 7.40% 1.04% 933 5.66% 94.34% 85.82% 7.47% 1.05%
144
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 934 5.65% 94.35% 85.83% 7.47% 1.05% 986 4.96% 95.04% 86.42% 7.56% 1.06%
935 5.64% 94.36% 85.84% 7.47% 1.05% 987 4.94% 95.06% 86.43% 7.56% 1.06%
936 5.63% 94.37% 85.85% 7.48% 1.05% 988 4.94% 95.07% 86.44% 7.56% 1.06%
937 5.61% 94.39% 85.86% 7.48% 1.05% 989 4.93% 95.08% 86.45% 7.56% 1.06%
938 5.59% 94.41% 85.88% 7.48% 1.05% 990 4.91% 95.09% 86.47% 7.57% 1.06%
939 5.58% 94.42% 85.89% 7.48% 1.05% 991 4.90% 95.10% 86.48% 7.57% 1.06%
940 5.55% 94.45% 85.91% 7.48% 1.05% 992 4.89% 95.11% 86.48% 7.57% 1.06%
941 5.54% 94.46% 85.93% 7.49% 1.05% 993 4.88% 95.12% 86.50% 7.57% 1.06%
942 5.52% 94.48% 85.94% 7.49% 1.05% 994 4.87% 95.13% 86.51% 7.57% 1.06%
943 5.50% 94.50% 85.96% 7.49% 1.05% 995 4.85% 95.15% 86.52% 7.57% 1.06%
944 5.49% 94.51% 85.97% 7.49% 1.05% 996 4.85% 95.15% 86.52% 7.57% 1.06%
945 5.48% 94.53% 85.98% 7.49% 1.05% 997 4.84% 95.16% 86.53% 7.57% 1.06%
946 5.46% 94.54% 86.00% 7.49% 1.05% 998 4.83% 95.18% 86.54% 7.57% 1.06%
947 5.45% 94.55% 86.01% 7.50% 1.05% 999 4.82% 95.18% 86.55% 7.57% 1.06%
948 5.43% 94.57% 86.02% 7.50% 1.05% 1000 4.81% 95.19% 86.56% 7.57% 1.06%
949 5.42% 94.58% 86.02% 7.50% 1.05% 1001 4.80% 95.20% 86.57% 7.57% 1.06%
950 5.41% 94.59% 86.04% 7.50% 1.05% 1002 4.79% 95.21% 86.58% 7.57% 1.06%
951 5.40% 94.61% 86.05% 7.50% 1.05% 1003 4.78% 95.22% 86.59% 7.57% 1.06%
952 5.39% 94.62% 86.06% 7.51% 1.05% 1004 4.77% 95.23% 86.59% 7.58% 1.06%
953 5.38% 94.63% 86.07% 7.51% 1.05% 1005 4.76% 95.24% 86.60% 7.58% 1.06%
954 5.36% 94.64% 86.08% 7.51% 1.05% 1006 4.74% 95.26% 86.62% 7.58% 1.06%
955 5.34% 94.66% 86.09% 7.51% 1.05% 1007 4.73% 95.27% 86.63% 7.58% 1.06%
956 5.33% 94.67% 86.10% 7.51% 1.05% 1008 4.72% 95.28% 86.63% 7.59% 1.06%
957 5.32% 94.68% 86.11% 7.52% 1.05% 1009 4.71% 95.29% 86.64% 7.59% 1.07%
958 5.31% 94.69% 86.12% 7.52% 1.05% 1010 4.69% 95.31% 86.66% 7.59% 1.07%
959 5.29% 94.71% 86.13% 7.52% 1.05% 1011 4.68% 95.32% 86.67% 7.59% 1.07%
960 5.28% 94.72% 86.14% 7.52% 1.05% 1012 4.67% 95.33% 86.68% 7.59% 1.07%
961 5.27% 94.73% 86.16% 7.52% 1.05% 1013 4.66% 95.34% 86.69% 7.59% 1.07%
962 5.26% 94.74% 86.16% 7.52% 1.05% 1014 4.65% 95.35% 86.69% 7.59% 1.07%
963 5.24% 94.76% 86.18% 7.53% 1.05% 1015 4.63% 95.37% 86.71% 7.60% 1.07%
964 5.23% 94.77% 86.19% 7.53% 1.05% 1016 4.62% 95.38% 86.72% 7.60% 1.07%
965 5.21% 94.79% 86.21% 7.53% 1.05% 1017 4.61% 95.39% 86.73% 7.60% 1.07%
966 5.19% 94.81% 86.22% 7.53% 1.05% 1018 4.60% 95.40% 86.73% 7.60% 1.07%
967 5.18% 94.82% 86.23% 7.54% 1.05% 1019 4.59% 95.41% 86.74% 7.60% 1.07%
968 5.16% 94.84% 86.24% 7.54% 1.06% 1020 4.58% 95.42% 86.75% 7.60% 1.07%
969 5.15% 94.85% 86.25% 7.54% 1.06% 1021 4.57% 95.43% 86.76% 7.61% 1.07%
970 5.15% 94.86% 86.26% 7.54% 1.06% 1022 4.56% 95.44% 86.77% 7.61% 1.07%
971 5.13% 94.87% 86.27% 7.54% 1.06% 1023 4.55% 95.45% 86.78% 7.61% 1.07%
972 5.12% 94.88% 86.28% 7.54% 1.06% 1024 4.53% 95.47% 86.79% 7.61% 1.07%
973 5.11% 94.89% 86.29% 7.55% 1.06% 1025 4.52% 95.48% 86.80% 7.61% 1.07%
974 5.10% 94.90% 86.30% 7.55% 1.06% 1026 4.50% 95.50% 86.82% 7.61% 1.07%
975 5.07% 94.93% 86.32% 7.55% 1.06% 1027 4.50% 95.51% 86.83% 7.61% 1.07%
976 5.06% 94.94% 86.33% 7.55% 1.06% 1028 4.49% 95.51% 86.83% 7.61% 1.07%
977 5.05% 94.95% 86.34% 7.55% 1.06% 1029 4.48% 95.52% 86.84% 7.61% 1.07%
978 5.04% 94.96% 86.35% 7.55% 1.06% 1030 4.47% 95.53% 86.85% 7.61% 1.07%
979 5.03% 94.97% 86.36% 7.55% 1.06% 1031 4.46% 95.54% 86.86% 7.61% 1.07%
980 5.02% 94.98% 86.37% 7.55% 1.06% 1032 4.46% 95.54% 86.86% 7.62% 1.07%
981 5.01% 94.99% 86.38% 7.56% 1.06% 1033 4.45% 95.55% 86.87% 7.62% 1.07%
982 5.00% 95.00% 86.39% 7.56% 1.06% 1034 4.44% 95.56% 86.88% 7.62% 1.07%
983 4.99% 95.01% 86.39% 7.56% 1.06% 1035 4.42% 95.58% 86.89% 7.62% 1.07%
984 4.98% 95.02% 86.40% 7.56% 1.06% 1036 4.42% 95.59% 86.90% 7.62% 1.07%
985 4.97% 95.03% 86.41% 7.56% 1.06% 1037 4.40% 95.60% 86.92% 7.62% 1.07%
145
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 1038 4.39% 95.61% 86.92% 7.62% 1.07% 1090 3.89% 96.11% 87.35% 7.68% 1.08%
1039 4.39% 95.62% 86.92% 7.62% 1.07% 1091 3.88% 96.12% 87.36% 7.69% 1.08%
1040 4.38% 95.62% 86.93% 7.62% 1.07% 1092 3.87% 96.13% 87.37% 7.69% 1.08%
1041 4.37% 95.63% 86.94% 7.62% 1.07% 1093 3.86% 96.14% 87.37% 7.69% 1.08%
1042 4.36% 95.64% 86.95% 7.63% 1.07% 1094 3.86% 96.14% 87.38% 7.69% 1.08%
1043 4.35% 95.65% 86.95% 7.63% 1.07% 1095 3.85% 96.15% 87.38% 7.69% 1.08%
1044 4.34% 95.66% 86.97% 7.63% 1.07% 1096 3.84% 96.16% 87.39% 7.69% 1.08%
1045 4.33% 95.67% 86.97% 7.63% 1.07% 1097 3.83% 96.17% 87.40% 7.69% 1.08%
1046 4.32% 95.68% 86.98% 7.63% 1.07% 1098 3.82% 96.18% 87.41% 7.69% 1.08%
1047 4.30% 95.70% 87.00% 7.63% 1.07% 1099 3.82% 96.19% 87.41% 7.69% 1.08%
1048 4.29% 95.71% 87.01% 7.64% 1.07% 1100 3.81% 96.19% 87.42% 7.69% 1.08%
1049 4.28% 95.72% 87.02% 7.64% 1.07% 1101 3.80% 96.20% 87.42% 7.70% 1.08%
1050 4.27% 95.73% 87.03% 7.64% 1.07% 1102 3.79% 96.21% 87.43% 7.70% 1.08%
1051 4.26% 95.75% 87.04% 7.64% 1.07% 1103 3.78% 96.22% 87.44% 7.70% 1.08%
1052 4.25% 95.76% 87.05% 7.64% 1.07% 1104 3.77% 96.23% 87.45% 7.70% 1.08%
1053 4.24% 95.76% 87.06% 7.64% 1.07% 1105 3.76% 96.24% 87.46% 7.70% 1.08%
1054 4.22% 95.78% 87.07% 7.64% 1.07% 1106 3.75% 96.25% 87.46% 7.71% 1.08%
1055 4.21% 95.79% 87.08% 7.64% 1.07% 1107 3.74% 96.26% 87.47% 7.71% 1.08%
1056 4.20% 95.80% 87.09% 7.64% 1.07% 1108 3.74% 96.27% 87.48% 7.71% 1.08%
1057 4.19% 95.81% 87.10% 7.64% 1.07% 1109 3.72% 96.28% 87.49% 7.71% 1.08%
1058 4.18% 95.82% 87.11% 7.64% 1.07% 1110 3.71% 96.29% 87.50% 7.71% 1.08%
1059 4.17% 95.83% 87.11% 7.65% 1.07% 1111 3.71% 96.29% 87.51% 7.71% 1.08%
1060 4.16% 95.84% 87.12% 7.65% 1.07% 1112 3.70% 96.30% 87.51% 7.71% 1.08%
1061 4.15% 95.85% 87.13% 7.65% 1.07% 1113 3.69% 96.31% 87.52% 7.71% 1.08%
1062 4.14% 95.86% 87.14% 7.65% 1.07% 1114 3.68% 96.32% 87.53% 7.71% 1.08%
1063 4.13% 95.87% 87.15% 7.65% 1.07% 1115 3.68% 96.32% 87.53% 7.71% 1.08%
1064 4.12% 95.88% 87.16% 7.65% 1.07% 1116 3.67% 96.33% 87.54% 7.71% 1.08%
1065 4.11% 95.89% 87.17% 7.65% 1.07% 1117 3.66% 96.34% 87.55% 7.71% 1.08%
1066 4.10% 95.90% 87.17% 7.65% 1.07% 1118 3.65% 96.35% 87.55% 7.71% 1.08%
1067 4.09% 95.91% 87.18% 7.65% 1.07% 1119 3.65% 96.35% 87.56% 7.71% 1.08%
1068 4.08% 95.92% 87.19% 7.66% 1.07% 1120 3.64% 96.36% 87.57% 7.71% 1.08%
1069 4.07% 95.93% 87.20% 7.66% 1.07% 1121 3.63% 96.37% 87.57% 7.72% 1.08%
1070 4.07% 95.93% 87.21% 7.66% 1.07% 1122 3.63% 96.37% 87.57% 7.72% 1.08%
1071 4.06% 95.94% 87.21% 7.66% 1.07% 1123 3.62% 96.38% 87.58% 7.72% 1.08%
1072 4.05% 95.95% 87.22% 7.66% 1.08% 1124 3.62% 96.38% 87.59% 7.72% 1.08%
1073 4.04% 95.96% 87.23% 7.66% 1.08% 1125 3.61% 96.39% 87.59% 7.72% 1.08%
1074 4.03% 95.97% 87.24% 7.66% 1.08% 1126 3.60% 96.40% 87.60% 7.72% 1.08%
1075 4.02% 95.98% 87.24% 7.66% 1.08% 1127 3.59% 96.41% 87.61% 7.72% 1.08%
1076 4.01% 95.99% 87.25% 7.66% 1.08% 1128 3.58% 96.42% 87.62% 7.72% 1.08%
1077 4.00% 96.00% 87.26% 7.67% 1.08% 1129 3.57% 96.43% 87.62% 7.72% 1.08%
1078 3.99% 96.01% 87.26% 7.67% 1.08% 1130 3.56% 96.44% 87.63% 7.72% 1.08%
1079 3.99% 96.02% 87.27% 7.67% 1.08% 1131 3.55% 96.45% 87.64% 7.72% 1.08%
1080 3.98% 96.02% 87.28% 7.67% 1.08% 1132 3.55% 96.45% 87.65% 7.72% 1.08%
1081 3.97% 96.04% 87.29% 7.67% 1.08% 1133 3.54% 96.46% 87.65% 7.73% 1.08%
1082 3.96% 96.04% 87.29% 7.67% 1.08% 1134 3.53% 96.47% 87.66% 7.73% 1.08%
1083 3.95% 96.05% 87.30% 7.67% 1.08% 1135 3.52% 96.48% 87.67% 7.73% 1.08%
1084 3.94% 96.06% 87.31% 7.67% 1.08% 1136 3.51% 96.49% 87.68% 7.73% 1.08%
1085 3.93% 96.07% 87.32% 7.68% 1.08% 1137 3.50% 96.50% 87.69% 7.73% 1.08%
1086 3.92% 96.08% 87.33% 7.68% 1.08% 1138 3.50% 96.51% 87.69% 7.73% 1.08%
1087 3.91% 96.09% 87.33% 7.68% 1.08% 1139 3.48% 96.52% 87.70% 7.73% 1.08%
1088 3.91% 96.10% 87.34% 7.68% 1.08% 1140 3.47% 96.53% 87.71% 7.73% 1.08%
1089 3.90% 96.10% 87.34% 7.68% 1.08% 1141 3.46% 96.55% 87.73% 7.74% 1.08%
146
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 1142 3.44% 96.56% 87.74% 7.74% 1.08% 1194 3.05% 96.95% 88.07% 7.79% 1.09%
1143 3.44% 96.57% 87.75% 7.74% 1.08% 1195 3.04% 96.96% 88.08% 7.79% 1.09%
1144 3.43% 96.57% 87.75% 7.74% 1.08% 1196 3.03% 96.97% 88.08% 7.79% 1.09%
1145 3.43% 96.58% 87.75% 7.74% 1.08% 1197 3.02% 96.98% 88.10% 7.79% 1.09%
1146 3.42% 96.58% 87.76% 7.74% 1.08% 1198 3.01% 96.99% 88.10% 7.79% 1.09%
1147 3.41% 96.59% 87.77% 7.74% 1.08% 1199 3.00% 97.00% 88.11% 7.79% 1.09%
1148 3.40% 96.60% 87.78% 7.74% 1.08% 1200 3.00% 97.00% 88.12% 7.79% 1.09%
1149 3.39% 96.61% 87.78% 7.74% 1.08%
1150 3.39% 96.62% 87.79% 7.74% 1.08%
1151 3.37% 96.63% 87.80% 7.74% 1.08%
1152 3.37% 96.63% 87.81% 7.74% 1.08%
1153 3.36% 96.64% 87.82% 7.74% 1.08%
1154 3.35% 96.65% 87.82% 7.74% 1.09%
1155 3.34% 96.66% 87.83% 7.74% 1.09%
1156 3.34% 96.67% 87.84% 7.75% 1.09%
1157 3.33% 96.67% 87.84% 7.75% 1.09%
1158 3.32% 96.68% 87.85% 7.75% 1.09%
1159 3.32% 96.69% 87.85% 7.75% 1.09%
1160 3.31% 96.69% 87.86% 7.75% 1.09%
1161 3.30% 96.70% 87.87% 7.75% 1.09%
1162 3.29% 96.71% 87.88% 7.75% 1.09%
1163 3.28% 96.72% 87.88% 7.75% 1.09%
1164 3.27% 96.73% 87.89% 7.75% 1.09%
1165 3.26% 96.74% 87.90% 7.75% 1.09%
1166 3.26% 96.74% 87.90% 7.75% 1.09%
1167 3.25% 96.75% 87.91% 7.76% 1.09%
1168 3.24% 96.76% 87.92% 7.76% 1.09%
1169 3.23% 96.77% 87.92% 7.76% 1.09%
1170 3.23% 96.77% 87.93% 7.76% 1.09%
1171 3.22% 96.78% 87.93% 7.76% 1.09%
1172 3.21% 96.79% 87.94% 7.76% 1.09%
1173 3.21% 96.79% 87.94% 7.76% 1.09%
1174 3.20% 96.80% 87.95% 7.76% 1.09%
1175 3.19% 96.81% 87.96% 7.76% 1.09%
1176 3.18% 96.82% 87.96% 7.76% 1.09%
1177 3.18% 96.82% 87.97% 7.76% 1.09%
1178 3.17% 96.83% 87.97% 7.77% 1.09%
1179 3.16% 96.84% 87.98% 7.77% 1.09%
1180 3.16% 96.85% 87.99% 7.77% 1.09%
1181 3.15% 96.86% 87.99% 7.77% 1.09%
1182 3.14% 96.86% 88.00% 7.77% 1.09%
1183 3.13% 96.87% 88.01% 7.77% 1.09%
1184 3.13% 96.87% 88.01% 7.77% 1.09%
1185 3.12% 96.88% 88.02% 7.77% 1.09%
1186 3.11% 96.89% 88.02% 7.77% 1.09%
1187 3.11% 96.89% 88.03% 7.78% 1.09%
1188 3.10% 96.90% 88.03% 7.78% 1.09%
1189 3.09% 96.91% 88.04% 7.78% 1.09%
1190 3.08% 96.92% 88.04% 7.78% 1.09%
1191 3.08% 96.92% 88.05% 7.79% 1.09%
1192 3.06% 96.94% 88.06% 7.79% 1.09%
1193 3.05% 96.95% 88.07% 7.79% 1.09%
147
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA
-314 98.02% 1.98% 1.98% 0.00% 0.00%
-313 98.00% 2.00% 2.00% 0.00% 0.00%
Table B2. LOCA Probability History for ASP-01
-312 97.99% 2.01% 2.01% 0.00% 0.00%
for Days After TOD
-311 97.98% 2.02% 2.02% 0.00% 0.00%
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA -310 97.97% 2.03% 2.03% 0.00% 0.00%
-365 98.61% 1.39% 1.39% 0.00% 0.00% -309 97.96% 2.05% 2.05% 0.00% 0.00%
-364 98.59% 1.41% 1.41% 0.00% 0.00% -308 97.93% 2.07% 2.07% 0.00% 0.00%
-363 98.59% 1.41% 1.41% 0.00% 0.00% -307 97.92% 2.08% 2.08% 0.00% 0.00%
-362 98.57% 1.43% 1.43% 0.00% 0.00% -306 97.91% 2.09% 2.09% 0.00% 0.00%
-361 98.56% 1.44% 1.44% 0.00% 0.00% -305 97.89% 2.11% 2.11% 0.00% 0.00%
-360 98.55% 1.45% 1.45% 0.00% 0.00% -304 97.88% 2.12% 2.12% 0.00% 0.00%
-359 98.54% 1.46% 1.46% 0.00% 0.00% -303 97.86% 2.14% 2.14% 0.00% 0.00%
-358 98.53% 1.47% 1.47% 0.00% 0.00% -302 97.85% 2.15% 2.15% 0.00% 0.00%
-357 98.52% 1.48% 1.48% 0.00% 0.00% -301 97.83% 2.17% 2.17% 0.00% 0.00%
-356 98.51% 1.49% 1.49% 0.00% 0.00% -300 97.81% 2.19% 2.19% 0.00% 0.00%
-355 98.50% 1.50% 1.50% 0.00% 0.00% -299 97.80% 2.20% 2.20% 0.00% 0.00%
-354 98.49% 1.51% 1.51% 0.00% 0.00% -298 97.79% 2.21% 2.21% 0.00% 0.00%
-353 98.48% 1.52% 1.52% 0.00% 0.00% -297 97.77% 2.23% 2.23% 0.00% 0.00%
-352 98.48% 1.52% 1.52% 0.00% 0.00% -296 97.75% 2.25% 2.25% 0.00% 0.00%
-351 98.47% 1.53% 1.53% 0.00% 0.00% -295 97.74% 2.26% 2.26% 0.00% 0.00%
-350 98.46% 1.54% 1.54% 0.00% 0.00% -294 97.72% 2.28% 2.28% 0.00% 0.00%
-349 98.44% 1.56% 1.56% 0.00% 0.00% -293 97.71% 2.29% 2.29% 0.00% 0.00%
-348 98.43% 1.57% 1.57% 0.00% 0.00% -292 97.69% 2.31% 2.31% 0.00% 0.00%
-347 98.42% 1.58% 1.58% 0.00% 0.00% -291 97.68% 2.33% 2.33% 0.00% 0.00%
-346 98.41% 1.59% 1.59% 0.00% 0.00% -290 97.66% 2.34% 2.34% 0.00% 0.00%
-345 98.39% 1.61% 1.61% 0.00% 0.00% -289 97.64% 2.36% 2.36% 0.00% 0.00%
-344 98.38% 1.62% 1.62% 0.00% 0.00% -288 97.62% 2.38% 2.38% 0.00% 0.00%
-343 98.38% 1.63% 1.63% 0.00% 0.00% -287 97.59% 2.41% 2.41% 0.00% 0.00%
-342 98.36% 1.64% 1.64% 0.00% 0.00% -286 97.57% 2.43% 2.43% 0.00% 0.00%
-341 98.35% 1.65% 1.65% 0.00% 0.00% -285 97.56% 2.44% 2.44% 0.00% 0.00%
-340 98.34% 1.66% 1.66% 0.00% 0.00% -284 97.54% 2.46% 2.46% 0.00% 0.00%
-339 98.33% 1.67% 1.67% 0.00% 0.00% -283 97.52% 2.48% 2.48% 0.00% 0.00%
-338 98.32% 1.69% 1.69% 0.00% 0.00% -282 97.50% 2.51% 2.50% 0.00% 0.00%
-337 98.30% 1.70% 1.70% 0.00% 0.00% -281 97.47% 2.53% 2.53% 0.00% 0.00%
-336 98.29% 1.71% 1.71% 0.00% 0.00% -280 97.46% 2.54% 2.54% 0.00% 0.00%
-335 98.28% 1.72% 1.72% 0.00% 0.00% -279 97.44% 2.56% 2.56% 0.00% 0.00%
-334 98.27% 1.74% 1.74% 0.00% 0.00% -278 97.43% 2.57% 2.57% 0.00% 0.00%
-333 98.25% 1.75% 1.75% 0.00% 0.00% -277 97.40% 2.60% 2.60% 0.00% 0.00%
-332 98.24% 1.76% 1.76% 0.00% 0.00% -276 97.38% 2.62% 2.62% 0.00% 0.00%
-331 98.23% 1.77% 1.77% 0.00% 0.00% -275 97.37% 2.63% 2.63% 0.00% 0.00%
-330 98.21% 1.79% 1.79% 0.00% 0.00% -274 97.35% 2.65% 2.65% 0.00% 0.00%
-329 98.21% 1.79% 1.79% 0.00% 0.00% -273 97.33% 2.67% 2.67% 0.00% 0.00%
-328 98.20% 1.80% 1.80% 0.00% 0.00% -272 97.32% 2.68% 2.68% 0.00% 0.00%
-327 98.18% 1.82% 1.82% 0.00% 0.00% -271 97.30% 2.70% 2.70% 0.00% 0.00%
-326 98.17% 1.83% 1.83% 0.00% 0.00% -270 97.28% 2.72% 2.72% 0.00% 0.00%
-325 98.16% 1.84% 1.84% 0.00% 0.00% -269 97.26% 2.74% 2.74% 0.00% 0.00%
-324 98.15% 1.86% 1.86% 0.00% 0.00% -268 97.24% 2.76% 2.75% 0.00% 0.00%
-323 98.13% 1.87% 1.87% 0.00% 0.00% -267 97.22% 2.78% 2.77% 0.00% 0.00%
-322 98.11% 1.89% 1.89% 0.00% 0.00% -266 97.20% 2.80% 2.79% 0.00% 0.00%
-321 98.11% 1.89% 1.89% 0.00% 0.00% -265 97.19% 2.81% 2.81% 0.00% 0.00%
-320 98.08% 1.92% 1.92% 0.00% 0.00% -264 97.18% 2.83% 2.82% 0.00% 0.00%
-319 98.07% 1.93% 1.93% 0.00% 0.00% -263 97.15% 2.85% 2.84% 0.00% 0.00%
-318 98.06% 1.94% 1.94% 0.00% 0.00% -262 97.13% 2.87% 2.87% 0.00% 0.00%
-317 98.05% 1.95% 1.95% 0.00% 0.00% -261 97.11% 2.89% 2.89% 0.00% 0.00%
-316 98.04% 1.96% 1.96% 0.00% 0.00% -260 97.09% 2.91% 2.91% 0.00% 0.00%
-315 98.03% 1.97% 1.97% 0.00% 0.00% -259 97.07% 2.93% 2.92% 0.00% 0.00%
148
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA
-258 97.06% 2.94% 2.94% 0.00% 0.00% -202 95.49% 4.51% 4.48% 0.02% 0.01%
-257 97.04% 2.96% 2.96% 0.00% 0.00% -201 95.45% 4.55% 4.52% 0.02% 0.02%
-256 97.01% 2.99% 2.98% 0.00% 0.00% -200 95.41% 4.59% 4.56% 0.02% 0.02%
-255 97.00% 3.00% 3.00% 0.00% 0.00% -199 95.38% 4.62% 4.59% 0.02% 0.02%
-254 96.98% 3.03% 3.02% 0.00% 0.00% -198 95.34% 4.67% 4.63% 0.02% 0.02%
-253 96.95% 3.05% 3.05% 0.00% 0.00% -197 95.30% 4.70% 4.67% 0.02% 0.02%
-252 96.93% 3.07% 3.07% 0.00% 0.00% -196 95.26% 4.74% 4.70% 0.02% 0.02%
-251 96.91% 3.10% 3.09% 0.00% 0.00% -195 95.23% 4.78% 4.74% 0.02% 0.02%
-250 96.88% 3.12% 3.12% 0.00% 0.00% -194 95.19% 4.81% 4.77% 0.02% 0.02%
-249 96.86% 3.14% 3.14% 0.00% 0.00% -193 95.14% 4.86% 4.82% 0.02% 0.02%
-248 96.83% 3.17% 3.17% 0.00% 0.00% -192 95.11% 4.89% 4.85% 0.02% 0.02%
-247 96.80% 3.20% 3.19% 0.00% 0.00% -191 95.07% 4.93% 4.88% 0.02% 0.02%
-246 96.78% 3.22% 3.22% 0.00% 0.00% -190 95.03% 4.98% 4.93% 0.02% 0.03%
-245 96.76% 3.24% 3.24% 0.00% 0.00% -189 94.98% 5.02% 4.97% 0.02% 0.03%
-244 96.73% 3.27% 3.27% 0.00% 0.00% -188 94.94% 5.06% 5.02% 0.02% 0.03%
-243 96.70% 3.30% 3.29% 0.00% 0.00% -187 94.90% 5.10% 5.05% 0.02% 0.03%
-242 96.67% 3.33% 3.33% 0.00% 0.00% -186 94.86% 5.14% 5.08% 0.02% 0.03%
-241 96.65% 3.35% 3.35% 0.00% 0.00% -185 94.83% 5.17% 5.11% 0.02% 0.03%
-240 96.63% 3.37% 3.36% 0.00% 0.00% -184 94.80% 5.20% 5.15% 0.02% 0.03%
-239 96.62% 3.38% 3.38% 0.00% 0.00% -183 94.75% 5.25% 5.20% 0.02% 0.03%
-238 96.58% 3.42% 3.41% 0.01% 0.00% -182 94.71% 5.29% 5.24% 0.02% 0.03%
-237 96.55% 3.45% 3.44% 0.01% 0.00% -181 94.65% 5.35% 5.29% 0.03% 0.04%
-236 96.53% 3.47% 3.47% 0.01% 0.00% -180 94.61% 5.39% 5.33% 0.03% 0.04%
-235 96.50% 3.51% 3.50% 0.01% 0.00% -179 94.57% 5.43% 5.36% 0.03% 0.04%
-234 96.47% 3.53% 3.52% 0.01% 0.00% -178 94.53% 5.47% 5.40% 0.03% 0.04%
-233 96.44% 3.57% 3.56% 0.01% 0.00% -177 94.48% 5.52% 5.45% 0.03% 0.04%
-232 96.40% 3.60% 3.59% 0.01% 0.00% -176 94.44% 5.56% 5.49% 0.03% 0.04%
-231 96.38% 3.62% 3.61% 0.01% 0.00% -175 94.39% 5.61% 5.54% 0.03% 0.04%
-230 96.35% 3.65% 3.64% 0.01% 0.00% -174 94.34% 5.66% 5.58% 0.04% 0.04%
-229 96.32% 3.69% 3.67% 0.01% 0.00% -173 94.30% 5.70% 5.62% 0.04% 0.05%
-228 96.28% 3.72% 3.71% 0.01% 0.00% -172 94.24% 5.76% 5.67% 0.04% 0.05%
-227 96.26% 3.74% 3.72% 0.01% 0.00% -171 94.21% 5.79% 5.71% 0.04% 0.05%
-226 96.23% 3.77% 3.76% 0.01% 0.00% -170 94.16% 5.84% 5.75% 0.04% 0.05%
-225 96.20% 3.80% 3.78% 0.01% 0.00% -169 94.13% 5.88% 5.78% 0.04% 0.05%
-224 96.17% 3.83% 3.81% 0.01% 0.01% -168 94.08% 5.92% 5.82% 0.04% 0.05%
-223 96.15% 3.86% 3.84% 0.01% 0.01% -167 94.03% 5.97% 5.87% 0.05% 0.05%
-222 96.12% 3.88% 3.86% 0.01% 0.01% -166 93.99% 6.01% 5.91% 0.05% 0.05%
-221 96.09% 3.91% 3.89% 0.01% 0.01% -165 93.95% 6.05% 5.95% 0.05% 0.06%
-220 96.06% 3.94% 3.92% 0.01% 0.01% -164 93.90% 6.10% 6.00% 0.05% 0.06%
-219 96.03% 3.97% 3.95% 0.01% 0.01% -163 93.86% 6.14% 6.03% 0.05% 0.06%
-218 96.00% 4.00% 3.98% 0.01% 0.01% -162 93.83% 6.17% 6.06% 0.05% 0.06%
-217 95.97% 4.03% 4.01% 0.02% 0.01% -161 93.77% 6.23% 6.12% 0.05% 0.06%
-216 95.94% 4.06% 4.04% 0.02% 0.01% -160 93.73% 6.27% 6.16% 0.05% 0.06%
-215 95.91% 4.09% 4.07% 0.02% 0.01% -159 93.69% 6.31% 6.19% 0.05% 0.06%
-214 95.88% 4.12% 4.09% 0.02% 0.01% -158 93.65% 6.35% 6.23% 0.05% 0.07%
-213 95.85% 4.16% 4.13% 0.02% 0.01% -157 93.60% 6.40% 6.28% 0.06% 0.07%
-212 95.82% 4.18% 4.15% 0.02% 0.01% -156 93.55% 6.45% 6.32% 0.06% 0.07%
-211 95.80% 4.20% 4.17% 0.02% 0.01% -155 93.50% 6.50% 6.37% 0.06% 0.07%
-210 95.77% 4.23% 4.21% 0.02% 0.01% -154 93.47% 6.53% 6.39% 0.06% 0.08%
-209 95.73% 4.27% 4.25% 0.02% 0.01% -153 93.43% 6.57% 6.43% 0.06% 0.08%
-208 95.69% 4.31% 4.28% 0.02% 0.01% -152 93.36% 6.64% 6.50% 0.06% 0.09%
-207 95.66% 4.34% 4.31% 0.02% 0.01% -151 93.30% 6.70% 6.55% 0.06% 0.09%
-206 95.62% 4.38% 4.35% 0.02% 0.01% -150 93.27% 6.74% 6.58% 0.06% 0.09%
-205 95.60% 4.40% 4.37% 0.02% 0.01% -149 93.22% 6.79% 6.63% 0.06% 0.09%
-204 95.57% 4.44% 4.41% 0.02% 0.01% -148 93.18% 6.82% 6.66% 0.06% 0.09%
-203 95.53% 4.47% 4.44% 0.02% 0.01% -147 93.13% 6.87% 6.70% 0.07% 0.10%
149
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA
-146 93.09% 6.92% 6.75% 0.07% 0.10% -90 89.34% 10.66% 10.02% 0.17% 0.47%
-145 93.04% 6.96% 6.80% 0.07% 0.10% -89 89.26% 10.74% 10.08% 0.17% 0.48%
-144 92.98% 7.02% 6.84% 0.07% 0.11% -88 89.19% 10.82% 10.15% 0.17% 0.50%
-143 92.93% 7.08% 6.90% 0.07% 0.11% -87 89.11% 10.89% 10.21% 0.18% 0.50%
-142 92.86% 7.14% 6.96% 0.07% 0.11% -86 89.03% 10.97% 10.27% 0.18% 0.51%
-141 92.83% 7.17% 6.98% 0.07% 0.12% -85 88.97% 11.04% 10.33% 0.18% 0.52%
-140 92.78% 7.22% 7.03% 0.07% 0.12% -84 88.88% 11.12% 10.40% 0.18% 0.54%
-139 92.71% 7.29% 7.09% 0.07% 0.13% -83 88.81% 11.20% 10.46% 0.19% 0.55%
-138 92.65% 7.35% 7.15% 0.07% 0.13% -82 88.73% 11.27% 10.53% 0.19% 0.56%
-137 92.60% 7.40% 7.20% 0.07% 0.13% -81 88.66% 11.34% 10.58% 0.19% 0.57%
-136 92.53% 7.47% 7.25% 0.07% 0.14% -80 88.58% 11.42% 10.64% 0.20% 0.58%
-135 92.48% 7.52% 7.30% 0.07% 0.14% -79 88.50% 11.50% 10.71% 0.20% 0.59%
-134 92.42% 7.58% 7.36% 0.08% 0.15% -78 88.42% 11.58% 10.77% 0.20% 0.61%
-133 92.36% 7.65% 7.42% 0.08% 0.15% -77 88.34% 11.66% 10.83% 0.21% 0.62%
-132 92.30% 7.70% 7.47% 0.08% 0.16% -76 88.26% 11.74% 10.90% 0.21% 0.63%
-131 92.24% 7.76% 7.52% 0.08% 0.16% -75 88.18% 11.82% 10.97% 0.21% 0.64%
-130 92.20% 7.80% 7.56% 0.08% 0.16% -74 88.09% 11.91% 11.04% 0.21% 0.65%
-129 92.14% 7.86% 7.61% 0.08% 0.17% -73 88.00% 12.00% 11.13% 0.22% 0.66%
-128 92.07% 7.93% 7.68% 0.08% 0.17% -72 87.90% 12.10% 11.21% 0.22% 0.67%
-127 92.01% 7.99% 7.73% 0.08% 0.18% -71 87.81% 12.19% 11.28% 0.22% 0.69%
-126 91.95% 8.06% 7.79% 0.09% 0.18% -70 87.73% 12.27% 11.35% 0.23% 0.70%
-125 91.90% 8.10% 7.83% 0.09% 0.18% -69 87.64% 12.36% 11.42% 0.23% 0.71%
-124 91.83% 8.18% 7.89% 0.09% 0.19% -68 87.57% 12.43% 11.48% 0.23% 0.73%
-123 91.78% 8.22% 7.94% 0.09% 0.19% -67 87.47% 12.53% 11.55% 0.23% 0.74%
-122 91.73% 8.27% 7.98% 0.10% 0.19% -66 87.38% 12.62% 11.63% 0.24% 0.76%
-121 91.67% 8.33% 8.03% 0.10% 0.20% -65 87.28% 12.72% 11.71% 0.24% 0.77%
-120 91.61% 8.39% 8.08% 0.10% 0.21% -64 87.18% 12.82% 11.78% 0.24% 0.80%
-119 91.53% 8.47% 8.15% 0.10% 0.22% -63 87.08% 12.92% 11.85% 0.25% 0.82%
-118 91.45% 8.55% 8.22% 0.11% 0.23% -62 86.98% 13.02% 11.94% 0.25% 0.84%
-117 91.38% 8.62% 8.28% 0.11% 0.24% -61 86.88% 13.12% 12.01% 0.25% 0.86%
-116 91.29% 8.71% 8.35% 0.11% 0.25% -60 86.78% 13.22% 12.09% 0.26% 0.87%
-115 91.21% 8.79% 8.42% 0.11% 0.26% -59 86.69% 13.31% 12.16% 0.26% 0.89%
-114 91.14% 8.86% 8.48% 0.11% 0.26% -58 86.59% 13.41% 12.24% 0.26% 0.91%
-113 91.07% 8.93% 8.54% 0.12% 0.27% -57 86.50% 13.50% 12.31% 0.27% 0.93%
-112 90.99% 9.01% 8.61% 0.12% 0.28% -56 86.39% 13.61% 12.39% 0.27% 0.95%
-111 90.92% 9.08% 8.67% 0.12% 0.29% -55 86.29% 13.71% 12.47% 0.27% 0.97%
-110 90.85% 9.15% 8.74% 0.12% 0.29% -54 86.19% 13.81% 12.55% 0.27% 0.99%
-109 90.78% 9.22% 8.80% 0.12% 0.30% -53 86.07% 13.93% 12.64% 0.28% 1.01%
-108 90.71% 9.29% 8.86% 0.12% 0.31% -52 85.99% 14.01% 12.71% 0.29% 1.02%
-107 90.64% 9.36% 8.91% 0.13% 0.32% -51 85.88% 14.12% 12.79% 0.30% 1.04%
-106 90.58% 9.42% 8.97% 0.13% 0.32% -50 85.79% 14.21% 12.85% 0.30% 1.06%
-105 90.51% 9.49% 9.03% 0.13% 0.33% -49 85.69% 14.32% 12.93% 0.31% 1.08%
-104 90.44% 9.56% 9.08% 0.13% 0.34% -48 85.60% 14.40% 13.00% 0.31% 1.10%
-103 90.37% 9.63% 9.15% 0.13% 0.35% -47 85.49% 14.51% 13.08% 0.31% 1.12%
-102 90.30% 9.70% 9.22% 0.14% 0.35% -46 85.38% 14.62% 13.17% 0.32% 1.14%
-101 90.21% 9.79% 9.30% 0.14% 0.36% -45 85.27% 14.73% 13.25% 0.32% 1.16%
-100 90.13% 9.87% 9.37% 0.14% 0.36% -44 85.17% 14.83% 13.33% 0.32% 1.18%
-99 90.07% 9.93% 9.42% 0.14% 0.37% -43 85.05% 14.95% 13.42% 0.33% 1.20%
-98 89.99% 10.01% 9.48% 0.14% 0.39% -42 84.92% 15.08% 13.51% 0.33% 1.23%
-97 89.88% 10.12% 9.57% 0.15% 0.40% -41 84.84% 15.16% 13.57% 0.34% 1.25%
-96 89.82% 10.19% 9.63% 0.15% 0.40% -40 84.76% 15.25% 13.64% 0.34% 1.27%
-95 89.74% 10.26% 9.69% 0.15% 0.42% -39 84.65% 15.35% 13.71% 0.34% 1.29%
-94 89.67% 10.33% 9.75% 0.16% 0.42% -38 84.54% 15.46% 13.79% 0.35% 1.32%
-93 89.59% 10.41% 9.81% 0.16% 0.44% -37 84.44% 15.56% 13.87% 0.35% 1.35%
-92 89.51% 10.49% 9.88% 0.16% 0.45% -36 84.33% 15.67% 13.95% 0.35% 1.37%
-91 89.43% 10.57% 9.95% 0.16% 0.46% -35 84.22% 15.78% 14.03% 0.35% 1.40%
150
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA
-34 84.11% 15.89% 14.11% 0.36% 1.43% 22 76.79% 23.21% 18.93% 0.62% 3.66%
-33 84.01% 15.99% 14.19% 0.36% 1.45% 23 76.64% 23.36% 19.03% 0.62% 3.72%
-32 83.92% 16.08% 14.25% 0.36% 1.47% 24 76.50% 23.50% 19.12% 0.62% 3.76%
-31 83.81% 16.19% 14.33% 0.36% 1.50% 25 76.34% 23.66% 19.22% 0.63% 3.82%
-30 83.70% 16.30% 14.41% 0.37% 1.53% 26 76.21% 23.79% 19.29% 0.63% 3.87%
-29 83.61% 16.40% 14.48% 0.37% 1.55% 27 76.05% 23.95% 19.40% 0.63% 3.92%
-28 83.50% 16.50% 14.56% 0.38% 1.56% 28 75.89% 24.11% 19.50% 0.64% 3.97%
-27 83.39% 16.61% 14.65% 0.38% 1.59% 29 75.76% 24.24% 19.58% 0.64% 4.02%
-26 83.29% 16.71% 14.72% 0.38% 1.61% 30 75.63% 24.37% 19.67% 0.64% 4.06%
-25 83.18% 16.82% 14.80% 0.39% 1.64% 31 75.49% 24.51% 19.76% 0.65% 4.11%
-24 83.09% 16.91% 14.87% 0.39% 1.65% 32 75.35% 24.65% 19.85% 0.65% 4.15%
-23 82.97% 17.03% 14.96% 0.39% 1.67% 33 75.21% 24.80% 19.95% 0.66% 4.19%
-22 82.85% 17.15% 15.06% 0.40% 1.69% 34 75.08% 24.92% 20.03% 0.66% 4.23%
-21 82.74% 17.26% 15.13% 0.40% 1.73% 35 74.95% 25.05% 20.11% 0.66% 4.28%
-20 82.62% 17.38% 15.22% 0.41% 1.76% 36 74.79% 25.21% 20.22% 0.67% 4.33%
-19 82.51% 17.50% 15.29% 0.41% 1.79% 37 74.63% 25.37% 20.31% 0.67% 4.38%
-18 82.40% 17.60% 15.37% 0.41% 1.82% 38 74.51% 25.50% 20.39% 0.68% 4.43%
-17 82.30% 17.70% 15.44% 0.42% 1.84% 39 74.36% 25.64% 20.48% 0.69% 4.48%
-16 82.18% 17.82% 15.53% 0.42% 1.87% 40 74.21% 25.79% 20.56% 0.70% 4.53%
-15 82.06% 17.94% 15.62% 0.43% 1.89% 41 74.07% 25.94% 20.66% 0.70% 4.58%
-14 81.95% 18.05% 15.69% 0.43% 1.93% 42 73.90% 26.10% 20.76% 0.71% 4.63%
-13 81.84% 18.16% 15.77% 0.44% 1.95% 43 73.76% 26.24% 20.86% 0.72% 4.67%
-12 81.71% 18.29% 15.87% 0.44% 1.98% 44 73.62% 26.38% 20.95% 0.72% 4.71%
-11 81.57% 18.43% 15.96% 0.44% 2.02% 45 73.48% 26.52% 21.03% 0.72% 4.76%
-10 81.44% 18.56% 16.05% 0.45% 2.06% 46 73.34% 26.66% 21.12% 0.73% 4.81%
-9 81.33% 18.67% 16.13% 0.45% 2.09% 47 73.21% 26.79% 21.20% 0.73% 4.86%
-8 81.19% 18.81% 16.23% 0.46% 2.12% 48 73.07% 26.93% 21.28% 0.73% 4.91%
-7 81.07% 18.93% 16.32% 0.46% 2.15% 49 72.91% 27.09% 21.38% 0.74% 4.97%
-6 80.93% 19.07% 16.40% 0.47% 2.20% 50 72.78% 27.23% 21.47% 0.74% 5.01%
-5 80.80% 19.20% 16.49% 0.47% 2.24% 51 72.63% 27.37% 21.56% 0.75% 5.07%
-4 80.68% 19.32% 16.57% 0.48% 2.27% 52 72.49% 27.51% 21.66% 0.75% 5.10%
-3 80.56% 19.44% 16.64% 0.48% 2.32% 53 72.36% 27.64% 21.74% 0.76% 5.14%
-2 80.42% 19.58% 16.74% 0.48% 2.36% 54 72.22% 27.78% 21.84% 0.76% 5.18%
-1 80.28% 19.73% 16.84% 0.49% 2.39% 55 72.09% 27.91% 21.93% 0.77% 5.22%
0 79.94% 20.07% 16.92% 0.50% 2.65% 56 71.96% 28.04% 22.01% 0.77% 5.26%
1 79.78% 20.22% 17.03% 0.51% 2.69% 57 71.82% 28.19% 22.11% 0.78% 5.29%
2 79.61% 20.39% 17.11% 0.51% 2.77% 58 71.69% 28.31% 22.20% 0.78% 5.33%
3 79.46% 20.55% 17.21% 0.52% 2.82% 59 71.54% 28.46% 22.30% 0.79% 5.38%
4 79.31% 20.69% 17.29% 0.52% 2.88% 60 71.41% 28.59% 22.39% 0.79% 5.41%
5 79.18% 20.82% 17.38% 0.53% 2.91% 61 71.25% 28.75% 22.49% 0.79% 5.46%
6 79.05% 20.95% 17.46% 0.53% 2.96% 62 71.12% 28.88% 22.58% 0.80% 5.50%
7 78.92% 21.08% 17.55% 0.54% 2.99% 63 70.98% 29.02% 22.67% 0.80% 5.54%
8 78.78% 21.22% 17.64% 0.54% 3.04% 64 70.84% 29.17% 22.77% 0.81% 5.59%
9 78.66% 21.34% 17.72% 0.55% 3.08% 65 70.70% 29.31% 22.85% 0.82% 5.64%
10 78.53% 21.47% 17.81% 0.55% 3.11% 66 70.55% 29.46% 22.95% 0.82% 5.68%
11 78.38% 21.62% 17.91% 0.55% 3.16% 67 70.41% 29.59% 23.04% 0.83% 5.73%
12 78.25% 21.76% 18.00% 0.56% 3.20% 68 70.28% 29.72% 23.12% 0.83% 5.77%
13 78.11% 21.89% 18.09% 0.56% 3.24% 69 70.14% 29.86% 23.21% 0.83% 5.82%
14 77.98% 22.02% 18.18% 0.57% 3.27% 70 69.99% 30.01% 23.31% 0.84% 5.86%
15 77.83% 22.17% 18.28% 0.58% 3.31% 71 69.83% 30.17% 23.41% 0.85% 5.91%
16 77.69% 22.31% 18.37% 0.58% 3.36% 72 69.67% 30.33% 23.51% 0.85% 5.97%
17 77.56% 22.44% 18.45% 0.58% 3.41% 73 69.52% 30.48% 23.61% 0.86% 6.01%
18 77.41% 22.59% 18.54% 0.59% 3.46% 74 69.36% 30.64% 23.73% 0.87% 6.04%
19 77.24% 22.76% 18.65% 0.60% 3.51% 75 69.23% 30.77% 23.81% 0.87% 6.10%
20 77.09% 22.91% 18.74% 0.60% 3.56% 76 69.08% 30.92% 23.91% 0.87% 6.14%
21 76.94% 23.07% 18.84% 0.61% 3.61% 77 68.94% 31.06% 24.00% 0.87% 6.19%
151
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 78 68.80% 31.20% 24.08% 0.88% 6.23% 134 60.49% 39.51% 29.35% 1.18% 8.98%
79 68.65% 31.36% 24.19% 0.89% 6.27% 135 60.35% 39.65% 29.44% 1.19% 9.03%
80 68.49% 31.51% 24.29% 0.90% 6.32% 136 60.21% 39.79% 29.52% 1.19% 9.08%
81 68.34% 31.66% 24.39% 0.91% 6.37% 137 60.07% 39.93% 29.62% 1.20% 9.12%
82 68.18% 31.82% 24.50% 0.91% 6.42% 138 59.92% 40.08% 29.70% 1.21% 9.17%
83 68.03% 31.97% 24.59% 0.92% 6.46% 139 59.78% 40.22% 29.78% 1.22% 9.22%
84 67.89% 32.11% 24.70% 0.92% 6.49% 140 59.64% 40.36% 29.87% 1.22% 9.27%
85 67.75% 32.26% 24.80% 0.92% 6.53% 141 59.49% 40.51% 29.96% 1.22% 9.32%
86 67.62% 32.38% 24.88% 0.93% 6.57% 142 59.35% 40.65% 30.05% 1.23% 9.37%
87 67.47% 32.53% 24.98% 0.94% 6.62% 143 59.19% 40.82% 30.14% 1.24% 9.44%
88 67.33% 32.68% 25.07% 0.94% 6.66% 144 59.03% 40.97% 30.24% 1.25% 9.49%
89 67.17% 32.83% 25.16% 0.95% 6.72% 145 58.88% 41.12% 30.32% 1.25% 9.55%
90 67.03% 32.97% 25.26% 0.96% 6.76% 146 58.72% 41.28% 30.42% 1.26% 9.61%
91 66.90% 33.11% 25.35% 0.96% 6.80% 147 58.59% 41.42% 30.49% 1.26% 9.66%
92 66.75% 33.26% 25.45% 0.96% 6.84% 148 58.43% 41.57% 30.58% 1.26% 9.73%
93 66.61% 33.39% 25.53% 0.97% 6.89% 149 58.30% 41.70% 30.66% 1.27% 9.78%
94 66.47% 33.53% 25.63% 0.97% 6.93% 150 58.17% 41.83% 30.73% 1.28% 9.82%
95 66.31% 33.69% 25.73% 0.98% 6.98% 151 58.05% 41.95% 30.81% 1.28% 9.87%
96 66.18% 33.83% 25.82% 0.98% 7.03% 152 57.90% 42.10% 30.89% 1.28% 9.93%
97 66.03% 33.97% 25.90% 0.99% 7.08% 153 57.76% 42.24% 30.96% 1.29% 9.99%
98 65.89% 34.11% 26.00% 1.00% 7.12% 154 57.60% 42.40% 31.05% 1.29% 10.05%
99 65.75% 34.25% 26.09% 1.00% 7.16% 155 57.45% 42.55% 31.14% 1.30% 10.11%
100 65.60% 34.40% 26.18% 1.00% 7.22% 156 57.33% 42.68% 31.21% 1.30% 10.17%
101 65.45% 34.55% 26.27% 1.01% 7.26% 157 57.17% 42.83% 31.30% 1.31% 10.22%
102 65.32% 34.68% 26.37% 1.02% 7.30% 158 57.02% 42.98% 31.39% 1.32% 10.27%
103 65.17% 34.83% 26.47% 1.02% 7.34% 159 56.90% 43.10% 31.47% 1.32% 10.32%
104 65.02% 34.99% 26.57% 1.03% 7.38% 160 56.77% 43.23% 31.54% 1.33% 10.37%
105 64.88% 35.12% 26.66% 1.03% 7.43% 161 56.66% 43.34% 31.62% 1.33% 10.40%
106 64.71% 35.29% 26.76% 1.04% 7.49% 162 56.53% 43.47% 31.70% 1.33% 10.44%
107 64.58% 35.42% 26.86% 1.04% 7.52% 163 56.41% 43.60% 31.78% 1.33% 10.48%
108 64.44% 35.56% 26.95% 1.05% 7.56% 164 56.27% 43.73% 31.85% 1.34% 10.53%
109 64.27% 35.73% 27.06% 1.06% 7.62% 165 56.14% 43.86% 31.93% 1.35% 10.58%
110 64.11% 35.89% 27.16% 1.07% 7.67% 166 56.02% 43.98% 32.00% 1.35% 10.63%
111 63.97% 36.03% 27.24% 1.08% 7.72% 167 55.88% 44.12% 32.09% 1.36% 10.67%
112 63.80% 36.20% 27.34% 1.08% 7.78% 168 55.76% 44.24% 32.15% 1.36% 10.72%
113 63.63% 36.37% 27.44% 1.09% 7.84% 169 55.63% 44.37% 32.24% 1.37% 10.76%
114 63.45% 36.55% 27.54% 1.10% 7.91% 170 55.52% 44.48% 32.31% 1.37% 10.80%
115 63.30% 36.70% 27.64% 1.10% 7.97% 171 55.38% 44.62% 32.38% 1.38% 10.85%
116 63.17% 36.84% 27.72% 1.10% 8.01% 172 55.26% 44.74% 32.46% 1.38% 10.90%
117 63.00% 37.01% 27.82% 1.11% 8.08% 173 55.12% 44.88% 32.55% 1.39% 10.95%
118 62.83% 37.17% 27.92% 1.12% 8.13% 174 54.99% 45.01% 32.63% 1.39% 11.00%
119 62.68% 37.32% 28.01% 1.12% 8.19% 175 54.83% 45.17% 32.72% 1.39% 11.05%
120 62.50% 37.50% 28.11% 1.12% 8.26% 176 54.71% 45.30% 32.81% 1.40% 11.09%
121 62.36% 37.64% 28.20% 1.13% 8.31% 177 54.58% 45.42% 32.89% 1.40% 11.13%
122 62.22% 37.78% 28.29% 1.13% 8.36% 178 54.47% 45.54% 32.97% 1.40% 11.17%
123 62.09% 37.91% 28.37% 1.14% 8.40% 179 54.34% 45.66% 33.04% 1.40% 11.22%
124 61.93% 38.07% 28.47% 1.14% 8.46% 180 54.22% 45.78% 33.11% 1.41% 11.26%
125 61.79% 38.21% 28.56% 1.15% 8.50% 181 54.08% 45.92% 33.19% 1.41% 11.31%
126 61.65% 38.35% 28.65% 1.15% 8.55% 182 53.95% 46.05% 33.29% 1.41% 11.35%
127 61.51% 38.49% 28.74% 1.15% 8.60% 183 53.81% 46.19% 33.37% 1.42% 11.40%
128 61.36% 38.64% 28.83% 1.16% 8.65% 184 53.66% 46.34% 33.45% 1.42% 11.46%
129 61.23% 38.77% 28.92% 1.16% 8.70% 185 53.56% 46.45% 33.52% 1.43% 11.50%
130 61.05% 38.95% 29.02% 1.17% 8.76% 186 53.43% 46.57% 33.59% 1.43% 11.55%
131 60.92% 39.08% 29.10% 1.17% 8.81% 187 53.31% 46.69% 33.66% 1.43% 11.60%
132 60.79% 39.21% 29.17% 1.17% 8.87% 188 53.19% 46.81% 33.74% 1.43% 11.64%
133 60.64% 39.36% 29.25% 1.18% 8.93% 189 53.06% 46.94% 33.82% 1.44% 11.69%
152
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 190 52.93% 47.07% 33.89% 1.45% 11.73% 246 46.55% 53.45% 37.71% 1.69% 14.06%
191 52.81% 47.19% 33.96% 1.45% 11.77% 247 46.41% 53.59% 37.78% 1.69% 14.12%
192 52.69% 47.31% 34.03% 1.45% 11.82% 248 46.30% 53.70% 37.86% 1.69% 14.15%
193 52.58% 47.42% 34.10% 1.46% 11.86% 249 46.20% 53.80% 37.91% 1.70% 14.19%
194 52.47% 47.53% 34.17% 1.47% 11.90% 250 46.09% 53.92% 37.99% 1.70% 14.23%
195 52.33% 47.68% 34.25% 1.47% 11.95% 251 45.96% 54.04% 38.07% 1.71% 14.26%
196 52.20% 47.80% 34.33% 1.48% 12.00% 252 45.85% 54.15% 38.14% 1.71% 14.30%
197 52.05% 47.95% 34.41% 1.48% 12.05% 253 45.77% 54.23% 38.19% 1.71% 14.34%
198 51.94% 48.06% 34.48% 1.49% 12.09% 254 45.67% 54.33% 38.24% 1.72% 14.37%
199 51.82% 48.18% 34.56% 1.49% 12.14% 255 45.56% 54.44% 38.30% 1.72% 14.42%
200 51.70% 48.30% 34.62% 1.50% 12.18% 256 45.45% 54.55% 38.36% 1.73% 14.46%
201 51.58% 48.42% 34.69% 1.50% 12.23% 257 45.35% 54.66% 38.43% 1.73% 14.50%
202 51.46% 48.54% 34.76% 1.51% 12.27% 258 45.23% 54.77% 38.48% 1.73% 14.55%
203 51.37% 48.63% 34.81% 1.51% 12.31% 259 45.13% 54.87% 38.53% 1.74% 14.61%
204 51.24% 48.76% 34.89% 1.51% 12.36% 260 45.03% 54.97% 38.58% 1.74% 14.65%
205 51.14% 48.86% 34.95% 1.52% 12.40% 261 44.91% 55.09% 38.66% 1.75% 14.69%
206 51.00% 49.00% 35.03% 1.52% 12.45% 262 44.81% 55.19% 38.72% 1.75% 14.72%
207 50.88% 49.12% 35.10% 1.53% 12.49% 263 44.71% 55.29% 38.78% 1.76% 14.75%
208 50.76% 49.24% 35.18% 1.53% 12.53% 264 44.62% 55.38% 38.84% 1.76% 14.78%
209 50.63% 49.37% 35.25% 1.54% 12.57% 265 44.52% 55.48% 38.90% 1.76% 14.83%
210 50.51% 49.49% 35.32% 1.55% 12.62% 266 44.41% 55.59% 38.95% 1.77% 14.87%
211 50.38% 49.62% 35.40% 1.55% 12.68% 267 44.31% 55.70% 39.01% 1.77% 14.91%
212 50.26% 49.74% 35.46% 1.56% 12.72% 268 44.21% 55.79% 39.06% 1.77% 14.96%
213 50.15% 49.85% 35.53% 1.56% 12.76% 269 44.11% 55.89% 39.13% 1.77% 14.99%
214 50.05% 49.95% 35.60% 1.56% 12.79% 270 44.01% 55.99% 39.18% 1.78% 15.03%
215 49.94% 50.06% 35.67% 1.57% 12.83% 271 43.91% 56.09% 39.24% 1.78% 15.07%
216 49.80% 50.20% 35.75% 1.57% 12.87% 272 43.83% 56.17% 39.29% 1.78% 15.10%
217 49.68% 50.33% 35.82% 1.58% 12.93% 273 43.75% 56.25% 39.33% 1.78% 15.14%
218 49.58% 50.42% 35.87% 1.58% 12.97% 274 43.64% 56.36% 39.40% 1.79% 15.17%
219 49.46% 50.54% 35.94% 1.59% 13.01% 275 43.54% 56.46% 39.46% 1.79% 15.21%
220 49.34% 50.66% 36.02% 1.59% 13.06% 276 43.43% 56.57% 39.54% 1.79% 15.24%
221 49.23% 50.77% 36.08% 1.59% 13.10% 277 43.33% 56.67% 39.60% 1.79% 15.28%
222 49.13% 50.88% 36.14% 1.60% 13.14% 278 43.24% 56.77% 39.65% 1.80% 15.32%
223 49.02% 50.98% 36.21% 1.60% 13.18% 279 43.13% 56.87% 39.72% 1.80% 15.35%
224 48.90% 51.10% 36.27% 1.60% 13.22% 280 43.05% 56.96% 39.78% 1.80% 15.38%
225 48.80% 51.21% 36.33% 1.61% 13.26% 281 42.94% 57.06% 39.84% 1.80% 15.42%
226 48.68% 51.32% 36.40% 1.61% 13.31% 282 42.85% 57.16% 39.89% 1.80% 15.46%
227 48.58% 51.42% 36.46% 1.61% 13.35% 283 42.76% 57.24% 39.94% 1.81% 15.49%
228 48.46% 51.54% 36.53% 1.62% 13.39% 284 42.68% 57.33% 40.00% 1.81% 15.52%
229 48.37% 51.63% 36.59% 1.62% 13.42% 285 42.58% 57.42% 40.06% 1.81% 15.56%
230 48.25% 51.75% 36.66% 1.62% 13.47% 286 42.48% 57.52% 40.12% 1.81% 15.59%
231 48.15% 51.85% 36.72% 1.63% 13.51% 287 42.37% 57.63% 40.19% 1.82% 15.62%
232 48.05% 51.95% 36.78% 1.63% 13.54% 288 42.25% 57.75% 40.25% 1.82% 15.67%
233 47.93% 52.07% 36.86% 1.63% 13.58% 289 42.13% 57.87% 40.32% 1.83% 15.71%
234 47.81% 52.19% 36.93% 1.64% 13.62% 290 42.04% 57.96% 40.39% 1.83% 15.74%
235 47.72% 52.28% 36.98% 1.64% 13.66% 291 41.96% 58.04% 40.44% 1.84% 15.77%
236 47.61% 52.39% 37.04% 1.65% 13.70% 292 41.86% 58.14% 40.50% 1.84% 15.80%
237 47.49% 52.51% 37.11% 1.65% 13.74% 293 41.77% 58.23% 40.54% 1.85% 15.84%
238 47.39% 52.61% 37.18% 1.66% 13.78% 294 41.68% 58.32% 40.59% 1.85% 15.87%
239 47.30% 52.71% 37.23% 1.66% 13.81% 295 41.59% 58.41% 40.65% 1.86% 15.91%
240 47.16% 52.84% 37.31% 1.67% 13.86% 296 41.51% 58.49% 40.69% 1.86% 15.93%
241 47.05% 52.95% 37.38% 1.67% 13.89% 297 41.43% 58.57% 40.75% 1.86% 15.96%
242 46.96% 53.04% 37.44% 1.67% 13.93% 298 41.34% 58.66% 40.80% 1.86% 16.00%
243 46.86% 53.14% 37.51% 1.67% 13.96% 299 41.25% 58.75% 40.85% 1.87% 16.03%
244 46.74% 53.26% 37.58% 1.68% 14.00% 300 41.15% 58.85% 40.91% 1.88% 16.06%
245 46.65% 53.35% 37.64% 1.68% 14.03% 301 41.07% 58.93% 40.96% 1.88% 16.10%
153
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 302 40.98% 59.02% 41.01% 1.88% 16.14% 358 36.33% 63.68% 43.75% 2.06% 17.87%
303 40.87% 59.13% 41.07% 1.89% 16.17% 359 36.25% 63.75% 43.79% 2.06% 17.90%
304 40.78% 59.22% 41.13% 1.89% 16.20% 360 36.17% 63.83% 43.83% 2.06% 17.93%
305 40.70% 59.30% 41.19% 1.90% 16.22% 361 36.10% 63.91% 43.88% 2.06% 17.96%
306 40.62% 59.39% 41.24% 1.90% 16.25% 362 36.02% 63.98% 43.92% 2.07% 17.99%
307 40.52% 59.48% 41.30% 1.90% 16.28% 363 35.96% 64.04% 43.97% 2.07% 18.01%
308 40.43% 59.57% 41.36% 1.90% 16.31% 364 35.88% 64.13% 44.02% 2.07% 18.03%
309 40.35% 59.65% 41.40% 1.91% 16.34% 365 35.81% 64.19% 44.05% 2.08% 18.06%
310 40.24% 59.76% 41.46% 1.91% 16.39% 366 35.74% 64.26% 44.09% 2.08% 18.10%
311 40.16% 59.84% 41.51% 1.91% 16.42% 367 35.68% 64.32% 44.13% 2.08% 18.12%
312 40.09% 59.91% 41.54% 1.92% 16.45% 368 35.61% 64.39% 44.17% 2.08% 18.14%
313 40.00% 60.00% 41.60% 1.92% 16.48% 369 35.54% 64.46% 44.21% 2.08% 18.16%
314 39.92% 60.08% 41.65% 1.93% 16.51% 370 35.46% 64.54% 44.27% 2.09% 18.18%
315 39.84% 60.17% 41.69% 1.93% 16.54% 371 35.40% 64.60% 44.31% 2.09% 18.20%
316 39.74% 60.26% 41.75% 1.93% 16.58% 372 35.33% 64.67% 44.35% 2.09% 18.23%
317 39.66% 60.34% 41.80% 1.94% 16.61% 373 35.25% 64.75% 44.40% 2.10% 18.26%
318 39.57% 60.43% 41.85% 1.94% 16.65% 374 35.17% 64.83% 44.44% 2.10% 18.29%
319 39.49% 60.51% 41.89% 1.94% 16.68% 375 35.09% 64.91% 44.49% 2.10% 18.32%
320 39.40% 60.60% 41.94% 1.94% 16.71% 376 35.04% 64.96% 44.53% 2.10% 18.34%
321 39.33% 60.67% 41.98% 1.94% 16.74% 377 34.97% 65.03% 44.56% 2.10% 18.36%
322 39.25% 60.75% 42.04% 1.95% 16.77% 378 34.89% 65.11% 44.61% 2.10% 18.40%
323 39.16% 60.84% 42.08% 1.95% 16.80% 379 34.83% 65.18% 44.65% 2.11% 18.42%
324 39.09% 60.91% 42.12% 1.96% 16.83% 380 34.76% 65.24% 44.68% 2.11% 18.45%
325 39.00% 61.00% 42.18% 1.96% 16.86% 381 34.69% 65.31% 44.73% 2.12% 18.47%
326 38.91% 61.09% 42.23% 1.96% 16.89% 382 34.62% 65.39% 44.77% 2.12% 18.50%
327 38.82% 61.19% 42.28% 1.97% 16.93% 383 34.56% 65.45% 44.80% 2.12% 18.52%
328 38.73% 61.27% 42.33% 1.97% 16.97% 384 34.49% 65.51% 44.83% 2.13% 18.55%
329 38.63% 61.37% 42.39% 1.97% 17.00% 385 34.41% 65.59% 44.89% 2.13% 18.57%
330 38.54% 61.46% 42.44% 1.98% 17.04% 386 34.36% 65.64% 44.91% 2.14% 18.59%
331 38.45% 61.55% 42.49% 1.98% 17.08% 387 34.29% 65.71% 44.95% 2.14% 18.62%
332 38.37% 61.63% 42.54% 1.98% 17.11% 388 34.21% 65.79% 45.00% 2.14% 18.66%
333 38.29% 61.71% 42.58% 1.98% 17.14% 389 34.14% 65.87% 45.05% 2.14% 18.68%
334 38.22% 61.78% 42.62% 1.98% 17.17% 390 34.06% 65.94% 45.09% 2.14% 18.71%
335 38.14% 61.86% 42.67% 1.99% 17.19% 391 33.99% 66.01% 45.13% 2.15% 18.74%
336 38.06% 61.94% 42.73% 2.00% 17.22% 392 33.91% 66.09% 45.18% 2.16% 18.76%
337 37.98% 62.02% 42.77% 2.00% 17.25% 393 33.84% 66.16% 45.22% 2.16% 18.78%
338 37.91% 62.09% 42.82% 2.00% 17.27% 394 33.77% 66.23% 45.27% 2.16% 18.80%
339 37.82% 62.18% 42.86% 2.00% 17.31% 395 33.71% 66.29% 45.30% 2.17% 18.82%
340 37.73% 62.27% 42.92% 2.01% 17.35% 396 33.65% 66.35% 45.34% 2.17% 18.85%
341 37.65% 62.35% 42.97% 2.01% 17.37% 397 33.59% 66.41% 45.38% 2.17% 18.87%
342 37.58% 62.42% 43.01% 2.01% 17.41% 398 33.52% 66.48% 45.42% 2.17% 18.90%
343 37.51% 62.49% 43.05% 2.01% 17.43% 399 33.46% 66.54% 45.45% 2.17% 18.93%
344 37.44% 62.56% 43.09% 2.01% 17.46% 400 33.40% 66.60% 45.49% 2.17% 18.94%
345 37.34% 62.66% 43.15% 2.02% 17.49% 401 33.34% 66.66% 45.53% 2.17% 18.96%
346 37.25% 62.75% 43.21% 2.02% 17.52% 402 33.27% 66.73% 45.57% 2.18% 18.99%
347 37.19% 62.82% 43.25% 2.02% 17.54% 403 33.19% 66.81% 45.61% 2.18% 19.02%
348 37.11% 62.89% 43.29% 2.03% 17.58% 404 33.12% 66.88% 45.66% 2.19% 19.04%
349 37.04% 62.97% 43.33% 2.03% 17.60% 405 33.05% 66.95% 45.70% 2.19% 19.07%
350 36.94% 63.06% 43.38% 2.04% 17.64% 406 32.99% 67.01% 45.73% 2.19% 19.09%
351 36.86% 63.14% 43.44% 2.04% 17.66% 407 32.94% 67.06% 45.76% 2.19% 19.11%
352 36.78% 63.22% 43.49% 2.04% 17.69% 408 32.89% 67.12% 45.79% 2.19% 19.13%
353 36.72% 63.28% 43.53% 2.04% 17.71% 409 32.82% 67.18% 45.83% 2.19% 19.16%
354 36.63% 63.37% 43.57% 2.05% 17.75% 410 32.77% 67.24% 45.87% 2.19% 19.17%
355 36.54% 63.46% 43.62% 2.05% 17.79% 411 32.70% 67.30% 45.91% 2.20% 19.20%
356 36.46% 63.54% 43.66% 2.06% 17.82% 412 32.64% 67.36% 45.95% 2.20% 19.22%
357 36.40% 63.60% 43.71% 2.06% 17.84% 413 32.57% 67.43% 45.99% 2.20% 19.24%
154
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 414 32.51% 67.49% 46.03% 2.20% 19.26% 470 29.20% 70.80% 48.01% 2.30% 20.49%
415 32.44% 67.56% 46.08% 2.20% 19.28% 471 29.13% 70.87% 48.05% 2.30% 20.51%
416 32.38% 67.62% 46.12% 2.20% 19.30% 472 29.08% 70.92% 48.09% 2.31% 20.53%
417 32.30% 67.70% 46.16% 2.20% 19.34% 473 29.02% 70.98% 48.13% 2.31% 20.54%
418 32.23% 67.77% 46.19% 2.21% 19.37% 474 28.96% 71.04% 48.17% 2.31% 20.57%
419 32.17% 67.83% 46.23% 2.21% 19.39% 475 28.90% 71.10% 48.20% 2.31% 20.59%
420 32.11% 67.89% 46.26% 2.21% 19.42% 476 28.86% 71.15% 48.23% 2.31% 20.60%
421 32.06% 67.94% 46.29% 2.21% 19.44% 477 28.80% 71.20% 48.25% 2.31% 20.63%
422 31.99% 68.01% 46.33% 2.22% 19.46% 478 28.74% 71.26% 48.29% 2.31% 20.66%
423 31.93% 68.07% 46.37% 2.22% 19.48% 479 28.69% 71.32% 48.32% 2.31% 20.68%
424 31.87% 68.13% 46.40% 2.22% 19.51% 480 28.63% 71.37% 48.36% 2.31% 20.69%
425 31.81% 68.19% 46.44% 2.22% 19.54% 481 28.59% 71.42% 48.39% 2.32% 20.71%
426 31.75% 68.25% 46.47% 2.22% 19.56% 482 28.53% 71.48% 48.42% 2.32% 20.74%
427 31.69% 68.31% 46.51% 2.22% 19.58% 483 28.48% 71.53% 48.45% 2.32% 20.76%
428 31.62% 68.38% 46.55% 2.23% 19.60% 484 28.42% 71.58% 48.48% 2.32% 20.78%
429 31.57% 68.43% 46.59% 2.23% 19.62% 485 28.37% 71.63% 48.51% 2.32% 20.80%
430 31.51% 68.49% 46.62% 2.23% 19.65% 486 28.32% 71.68% 48.54% 2.33% 20.82%
431 31.46% 68.54% 46.65% 2.23% 19.66% 487 28.27% 71.73% 48.57% 2.33% 20.84%
432 31.40% 68.60% 46.69% 2.23% 19.68% 488 28.22% 71.78% 48.60% 2.33% 20.85%
433 31.33% 68.67% 46.73% 2.24% 19.71% 489 28.17% 71.83% 48.63% 2.33% 20.87%
434 31.28% 68.72% 46.76% 2.24% 19.73% 490 28.12% 71.89% 48.66% 2.33% 20.89%
435 31.23% 68.77% 46.79% 2.24% 19.74% 491 28.06% 71.94% 48.69% 2.34% 20.91%
436 31.16% 68.84% 46.83% 2.24% 19.77% 492 28.01% 71.99% 48.72% 2.34% 20.93%
437 31.11% 68.89% 46.87% 2.24% 19.79% 493 27.96% 72.04% 48.75% 2.34% 20.95%
438 31.05% 68.95% 46.90% 2.24% 19.81% 494 27.90% 72.10% 48.79% 2.34% 20.97%
439 31.00% 69.00% 46.93% 2.25% 19.82% 495 27.85% 72.15% 48.81% 2.34% 21.00%
440 30.93% 69.07% 46.97% 2.25% 19.84% 496 27.81% 72.19% 48.84% 2.34% 21.01%
441 30.88% 69.12% 47.00% 2.26% 19.86% 497 27.76% 72.24% 48.87% 2.34% 21.03%
442 30.82% 69.18% 47.04% 2.26% 19.89% 498 27.70% 72.30% 48.90% 2.34% 21.06%
443 30.76% 69.24% 47.07% 2.26% 19.91% 499 27.64% 72.36% 48.93% 2.35% 21.08%
444 30.70% 69.30% 47.10% 2.26% 19.93% 500 27.59% 72.41% 48.97% 2.35% 21.10%
445 30.64% 69.36% 47.14% 2.27% 19.95% 501 27.53% 72.47% 49.01% 2.35% 21.12%
446 30.58% 69.42% 47.17% 2.27% 19.98% 502 27.48% 72.53% 49.04% 2.35% 21.13%
447 30.52% 69.48% 47.21% 2.27% 20.01% 503 27.41% 72.59% 49.07% 2.35% 21.17%
448 30.46% 69.54% 47.24% 2.27% 20.03% 504 27.36% 72.64% 49.10% 2.35% 21.19%
449 30.39% 69.61% 47.29% 2.27% 20.06% 505 27.30% 72.70% 49.13% 2.35% 21.21%
450 30.33% 69.67% 47.32% 2.27% 20.08% 506 27.25% 72.75% 49.17% 2.36% 21.23%
451 30.26% 69.74% 47.36% 2.27% 20.11% 507 27.21% 72.79% 49.19% 2.36% 21.24%
452 30.21% 69.79% 47.39% 2.27% 20.13% 508 27.15% 72.85% 49.22% 2.36% 21.27%
453 30.15% 69.85% 47.44% 2.27% 20.14% 509 27.09% 72.92% 49.26% 2.37% 21.29%
454 30.09% 69.91% 47.47% 2.28% 20.16% 510 27.04% 72.96% 49.29% 2.37% 21.30%
455 30.04% 69.96% 47.50% 2.28% 20.18% 511 26.99% 73.01% 49.31% 2.37% 21.32%
456 29.99% 70.01% 47.53% 2.28% 20.20% 512 26.94% 73.06% 49.34% 2.38% 21.34%
457 29.93% 70.07% 47.57% 2.28% 20.23% 513 26.90% 73.10% 49.37% 2.38% 21.35%
458 29.87% 70.13% 47.60% 2.29% 20.25% 514 26.86% 73.14% 49.39% 2.38% 21.37%
459 29.83% 70.18% 47.62% 2.29% 20.27% 515 26.80% 73.20% 49.42% 2.39% 21.39%
460 29.77% 70.23% 47.65% 2.29% 20.29% 516 26.75% 73.25% 49.45% 2.39% 21.41%
461 29.72% 70.28% 47.69% 2.29% 20.31% 517 26.70% 73.30% 49.48% 2.39% 21.43%
462 29.66% 70.34% 47.72% 2.29% 20.33% 518 26.65% 73.35% 49.51% 2.39% 21.46%
463 29.61% 70.39% 47.76% 2.29% 20.34% 519 26.59% 73.41% 49.54% 2.39% 21.48%
464 29.54% 70.46% 47.80% 2.29% 20.37% 520 26.54% 73.46% 49.56% 2.39% 21.50%
465 29.48% 70.52% 47.85% 2.29% 20.38% 521 26.50% 73.50% 49.59% 2.39% 21.52%
466 29.42% 70.58% 47.88% 2.29% 20.40% 522 26.45% 73.55% 49.62% 2.39% 21.54%
467 29.36% 70.65% 47.92% 2.30% 20.43% 523 26.40% 73.60% 49.65% 2.40% 21.56%
468 29.30% 70.70% 47.95% 2.30% 20.45% 524 26.35% 73.65% 49.68% 2.40% 21.57%
469 29.25% 70.75% 47.98% 2.30% 20.47% 525 26.31% 73.69% 49.70% 2.41% 21.59%
155
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 526 26.27% 73.73% 49.72% 2.41% 21.61% 582 23.75% 76.25% 51.19% 2.50% 22.57%
527 26.23% 73.77% 49.74% 2.41% 21.62% 583 23.71% 76.29% 51.21% 2.50% 22.58%
528 26.18% 73.82% 49.77% 2.41% 21.64% 584 23.66% 76.34% 51.25% 2.50% 22.60%
529 26.14% 73.86% 49.79% 2.41% 21.65% 585 23.61% 76.39% 51.27% 2.50% 22.61%
530 26.10% 73.90% 49.82% 2.41% 21.67% 586 23.57% 76.43% 51.30% 2.50% 22.63%
531 26.04% 73.96% 49.85% 2.42% 21.69% 587 23.52% 76.48% 51.32% 2.50% 22.65%
532 26.00% 74.00% 49.88% 2.42% 21.70% 588 23.47% 76.53% 51.36% 2.50% 22.67%
533 25.96% 74.04% 49.90% 2.42% 21.72% 589 23.42% 76.58% 51.39% 2.51% 22.69%
534 25.91% 74.09% 49.93% 2.42% 21.74% 590 23.38% 76.62% 51.41% 2.51% 22.70%
535 25.86% 74.14% 49.95% 2.42% 21.77% 591 23.35% 76.65% 51.43% 2.51% 22.72%
536 25.82% 74.18% 49.97% 2.42% 21.79% 592 23.30% 76.70% 51.46% 2.51% 22.74%
537 25.77% 74.23% 50.00% 2.42% 21.81% 593 23.25% 76.75% 51.48% 2.51% 22.76%
538 25.72% 74.28% 50.03% 2.42% 21.83% 594 23.21% 76.79% 51.50% 2.51% 22.78%
539 25.68% 74.32% 50.06% 2.43% 21.84% 595 23.17% 76.83% 51.52% 2.51% 22.79%
540 25.63% 74.37% 50.08% 2.43% 21.86% 596 23.14% 76.86% 51.54% 2.51% 22.81%
541 25.60% 74.40% 50.10% 2.43% 21.87% 597 23.10% 76.90% 51.56% 2.51% 22.83%
542 25.55% 74.45% 50.13% 2.43% 21.89% 598 23.07% 76.93% 51.58% 2.51% 22.84%
543 25.50% 74.50% 50.15% 2.44% 21.91% 599 23.02% 76.98% 51.61% 2.52% 22.85%
544 25.45% 74.55% 50.18% 2.44% 21.93% 600 22.98% 77.02% 51.64% 2.52% 22.87%
545 25.40% 74.60% 50.21% 2.44% 21.95% 601 22.95% 77.05% 51.66% 2.52% 22.88%
546 25.35% 74.65% 50.24% 2.44% 21.97% 602 22.91% 77.09% 51.68% 2.52% 22.89%
547 25.30% 74.70% 50.26% 2.44% 21.99% 603 22.87% 77.13% 51.70% 2.52% 22.91%
548 25.25% 74.75% 50.30% 2.45% 22.01% 604 22.84% 77.16% 51.72% 2.52% 22.92%
549 25.21% 74.79% 50.32% 2.45% 22.02% 605 22.79% 77.21% 51.74% 2.53% 22.94%
550 25.16% 74.84% 50.35% 2.45% 22.04% 606 22.75% 77.25% 51.76% 2.53% 22.96%
551 25.12% 74.88% 50.38% 2.45% 22.05% 607 22.71% 77.29% 51.78% 2.53% 22.98%
552 25.06% 74.94% 50.41% 2.46% 22.07% 608 22.67% 77.33% 51.80% 2.53% 23.00%
553 25.01% 74.99% 50.44% 2.46% 22.09% 609 22.63% 77.38% 51.83% 2.53% 23.01%
554 24.96% 75.05% 50.48% 2.46% 22.11% 610 22.59% 77.41% 51.85% 2.54% 23.03%
555 24.90% 75.10% 50.51% 2.46% 22.13% 611 22.55% 77.45% 51.87% 2.54% 23.04%
556 24.87% 75.13% 50.53% 2.46% 22.14% 612 22.51% 77.49% 51.89% 2.54% 23.06%
557 24.82% 75.18% 50.56% 2.46% 22.16% 613 22.48% 77.52% 51.90% 2.54% 23.08%
558 24.77% 75.23% 50.59% 2.46% 22.18% 614 22.43% 77.57% 51.93% 2.54% 23.10%
559 24.73% 75.27% 50.61% 2.46% 22.19% 615 22.39% 77.61% 51.96% 2.54% 23.12%
560 24.68% 75.32% 50.64% 2.47% 22.21% 616 22.35% 77.65% 51.98% 2.54% 23.13%
561 24.64% 75.36% 50.66% 2.47% 22.23% 617 22.31% 77.69% 52.00% 2.55% 23.14%
562 24.60% 75.40% 50.69% 2.47% 22.24% 618 22.27% 77.73% 52.02% 2.55% 23.16%
563 24.56% 75.44% 50.71% 2.47% 22.25% 619 22.24% 77.76% 52.04% 2.55% 23.17%
564 24.52% 75.48% 50.74% 2.48% 22.27% 620 22.19% 77.81% 52.07% 2.55% 23.19%
565 24.48% 75.52% 50.76% 2.48% 22.28% 621 22.15% 77.85% 52.09% 2.55% 23.21%
566 24.44% 75.56% 50.78% 2.48% 22.31% 622 22.11% 77.89% 52.11% 2.55% 23.23%
567 24.40% 75.60% 50.81% 2.48% 22.32% 623 22.07% 77.93% 52.13% 2.55% 23.24%
568 24.35% 75.65% 50.84% 2.48% 22.34% 624 22.04% 77.96% 52.15% 2.55% 23.26%
569 24.31% 75.69% 50.86% 2.48% 22.35% 625 21.99% 78.01% 52.17% 2.56% 23.28%
570 24.27% 75.73% 50.88% 2.48% 22.37% 626 21.96% 78.05% 52.19% 2.56% 23.30%
571 24.22% 75.78% 50.91% 2.48% 22.38% 627 21.91% 78.09% 52.21% 2.56% 23.32%
572 24.19% 75.82% 50.94% 2.48% 22.40% 628 21.87% 78.13% 52.23% 2.56% 23.33%
573 24.14% 75.86% 50.97% 2.49% 22.41% 629 21.84% 78.16% 52.25% 2.56% 23.35%
574 24.09% 75.91% 51.00% 2.49% 22.43% 630 21.80% 78.20% 52.27% 2.57% 23.36%
575 24.05% 75.95% 51.02% 2.49% 22.45% 631 21.76% 78.24% 52.29% 2.57% 23.38%
576 24.01% 76.00% 51.05% 2.49% 22.46% 632 21.73% 78.27% 52.31% 2.57% 23.39%
577 23.96% 76.04% 51.07% 2.49% 22.48% 633 21.70% 78.30% 52.33% 2.57% 23.40%
578 23.91% 76.09% 51.10% 2.49% 22.50% 634 21.66% 78.34% 52.35% 2.57% 23.42%
579 23.88% 76.13% 51.12% 2.49% 22.52% 635 21.62% 78.38% 52.38% 2.57% 23.43%
580 23.83% 76.17% 51.14% 2.49% 22.53% 636 21.59% 78.41% 52.40% 2.57% 23.44%
581 23.78% 76.22% 51.17% 2.50% 22.55% 637 21.55% 78.45% 52.42% 2.57% 23.45%
156
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 638 21.52% 78.48% 52.43% 2.57% 23.47% 694 19.55% 80.45% 53.55% 2.64% 24.25%
639 21.49% 78.51% 52.45% 2.58% 23.48% 695 19.53% 80.48% 53.57% 2.65% 24.26%
640 21.46% 78.54% 52.47% 2.58% 23.49% 696 19.50% 80.50% 53.59% 2.65% 24.27%
641 21.43% 78.57% 52.49% 2.58% 23.50% 697 19.47% 80.53% 53.60% 2.65% 24.28%
642 21.40% 78.61% 52.51% 2.58% 23.51% 698 19.44% 80.56% 53.62% 2.65% 24.30%
643 21.36% 78.64% 52.53% 2.58% 23.52% 699 19.41% 80.59% 53.63% 2.65% 24.31%
644 21.34% 78.67% 52.55% 2.58% 23.54% 700 19.38% 80.62% 53.65% 2.65% 24.32%
645 21.30% 78.70% 52.57% 2.58% 23.55% 701 19.34% 80.66% 53.68% 2.65% 24.33%
646 21.27% 78.73% 52.58% 2.58% 23.57% 702 19.31% 80.69% 53.69% 2.65% 24.35%
647 21.23% 78.77% 52.61% 2.59% 23.58% 703 19.28% 80.72% 53.71% 2.65% 24.36%
648 21.19% 78.81% 52.62% 2.59% 23.61% 704 19.26% 80.74% 53.72% 2.65% 24.37%
649 21.16% 78.84% 52.64% 2.59% 23.61% 705 19.23% 80.77% 53.73% 2.65% 24.39%
650 21.12% 78.89% 52.67% 2.59% 23.63% 706 19.20% 80.80% 53.75% 2.65% 24.40%
651 21.08% 78.92% 52.68% 2.59% 23.64% 707 19.17% 80.83% 53.77% 2.66% 24.41%
652 21.05% 78.95% 52.70% 2.59% 23.66% 708 19.14% 80.86% 53.78% 2.66% 24.43%
653 21.00% 79.00% 52.73% 2.59% 23.68% 709 19.10% 80.90% 53.81% 2.66% 24.44%
654 20.97% 79.03% 52.74% 2.59% 23.69% 710 19.06% 80.94% 53.82% 2.66% 24.45%
655 20.94% 79.06% 52.76% 2.59% 23.71% 711 19.05% 80.96% 53.83% 2.66% 24.46%
656 20.90% 79.10% 52.78% 2.59% 23.73% 712 19.02% 80.98% 53.85% 2.66% 24.47%
657 20.86% 79.14% 52.80% 2.59% 23.75% 713 18.99% 81.01% 53.86% 2.66% 24.49%
658 20.82% 79.18% 52.83% 2.59% 23.76% 714 18.96% 81.04% 53.87% 2.66% 24.50%
659 20.79% 79.21% 52.85% 2.60% 23.77% 715 18.94% 81.07% 53.88% 2.66% 24.52%
660 20.75% 79.25% 52.87% 2.60% 23.78% 716 18.90% 81.10% 53.90% 2.67% 24.53%
661 20.72% 79.28% 52.89% 2.60% 23.79% 717 18.86% 81.14% 53.92% 2.67% 24.55%
662 20.68% 79.32% 52.92% 2.60% 23.81% 718 18.83% 81.17% 53.94% 2.67% 24.56%
663 20.65% 79.35% 52.93% 2.60% 23.82% 719 18.80% 81.20% 53.95% 2.67% 24.58%
664 20.60% 79.40% 52.95% 2.60% 23.84% 720 18.78% 81.22% 53.96% 2.67% 24.59%
665 20.57% 79.43% 52.97% 2.60% 23.85% 721 18.74% 81.26% 53.98% 2.67% 24.60%
666 20.55% 79.46% 52.99% 2.61% 23.86% 722 18.71% 81.29% 54.00% 2.67% 24.61%
667 20.51% 79.49% 53.00% 2.61% 23.88% 723 18.68% 81.32% 54.02% 2.68% 24.63%
668 20.47% 79.53% 53.03% 2.61% 23.89% 724 18.66% 81.34% 54.03% 2.68% 24.64%
669 20.44% 79.56% 53.04% 2.61% 23.90% 725 18.63% 81.37% 54.05% 2.68% 24.65%
670 20.40% 79.60% 53.07% 2.61% 23.92% 726 18.61% 81.39% 54.05% 2.68% 24.66%
671 20.35% 79.65% 53.10% 2.61% 23.94% 727 18.58% 81.42% 54.07% 2.68% 24.67%
672 20.31% 79.69% 53.12% 2.62% 23.96% 728 18.54% 81.46% 54.09% 2.68% 24.69%
673 20.27% 79.73% 53.14% 2.62% 23.97% 729 18.51% 81.49% 54.11% 2.68% 24.70%
674 20.24% 79.76% 53.16% 2.62% 23.99% 730 18.49% 81.51% 54.13% 2.68% 24.71%
675 20.20% 79.80% 53.18% 2.62% 24.01% 731 18.46% 81.54% 54.14% 2.68% 24.72%
676 20.17% 79.83% 53.19% 2.62% 24.02% 732 18.42% 81.58% 54.16% 2.68% 24.73%
677 20.14% 79.86% 53.21% 2.62% 24.03% 733 18.39% 81.61% 54.18% 2.68% 24.74%
678 20.10% 79.90% 53.23% 2.62% 24.04% 734 18.37% 81.63% 54.19% 2.68% 24.75%
679 20.07% 79.93% 53.25% 2.63% 24.05% 735 18.34% 81.66% 54.21% 2.68% 24.77%
680 20.02% 79.98% 53.28% 2.63% 24.07% 736 18.31% 81.69% 54.22% 2.69% 24.78%
681 19.99% 80.01% 53.30% 2.63% 24.08% 737 18.29% 81.71% 54.24% 2.69% 24.79%
682 19.96% 80.04% 53.32% 2.63% 24.09% 738 18.25% 81.75% 54.26% 2.69% 24.80%
683 19.92% 80.08% 53.34% 2.64% 24.10% 739 18.21% 81.79% 54.28% 2.69% 24.82%
684 19.89% 80.12% 53.36% 2.64% 24.12% 740 18.17% 81.83% 54.29% 2.69% 24.84%
685 19.86% 80.14% 53.37% 2.64% 24.13% 741 18.14% 81.86% 54.31% 2.69% 24.85%
686 19.82% 80.18% 53.39% 2.64% 24.15% 742 18.11% 81.89% 54.33% 2.70% 24.86%
687 19.79% 80.21% 53.41% 2.64% 24.16% 743 18.09% 81.92% 54.34% 2.70% 24.88%
688 19.75% 80.25% 53.44% 2.64% 24.17% 744 18.06% 81.94% 54.35% 2.70% 24.89%
689 19.71% 80.29% 53.46% 2.64% 24.18% 745 18.03% 81.97% 54.37% 2.70% 24.90%
690 19.69% 80.32% 53.48% 2.64% 24.20% 746 18.01% 82.00% 54.38% 2.70% 24.91%
691 19.66% 80.34% 53.49% 2.64% 24.21% 747 17.98% 82.02% 54.39% 2.70% 24.92%
692 19.62% 80.39% 53.52% 2.64% 24.22% 748 17.95% 82.05% 54.41% 2.71% 24.94%
693 19.58% 80.42% 53.54% 2.64% 24.24% 749 17.92% 82.08% 54.43% 2.71% 24.95%
157
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 750 17.88% 82.12% 54.45% 2.71% 24.96% 806 16.43% 83.57% 55.26% 2.76% 25.55%
751 17.85% 82.15% 54.47% 2.71% 24.97% 807 16.41% 83.59% 55.27% 2.76% 25.56%
752 17.82% 82.18% 54.48% 2.71% 24.98% 808 16.38% 83.62% 55.28% 2.76% 25.58%
753 17.80% 82.20% 54.49% 2.71% 24.99% 809 16.35% 83.65% 55.29% 2.77% 25.59%
754 17.77% 82.23% 54.51% 2.71% 25.00% 810 16.33% 83.67% 55.31% 2.77% 25.60%
755 17.74% 82.26% 54.52% 2.72% 25.02% 811 16.31% 83.69% 55.32% 2.77% 25.61%
756 17.73% 82.27% 54.53% 2.72% 25.02% 812 16.28% 83.72% 55.33% 2.77% 25.62%
757 17.70% 82.30% 54.54% 2.72% 25.04% 813 16.26% 83.74% 55.34% 2.77% 25.63%
758 17.67% 82.33% 54.56% 2.72% 25.05% 814 16.23% 83.77% 55.37% 2.77% 25.63%
759 17.65% 82.35% 54.57% 2.72% 25.06% 815 16.20% 83.80% 55.38% 2.77% 25.64%
760 17.62% 82.38% 54.60% 2.72% 25.07% 816 16.18% 83.82% 55.40% 2.78% 25.65%
761 17.58% 82.42% 54.61% 2.72% 25.08% 817 16.15% 83.85% 55.41% 2.78% 25.66%
762 17.56% 82.44% 54.63% 2.72% 25.10% 818 16.12% 83.88% 55.42% 2.78% 25.68%
763 17.53% 82.48% 54.64% 2.72% 25.11% 819 16.10% 83.90% 55.43% 2.78% 25.69%
764 17.50% 82.50% 54.65% 2.73% 25.12% 820 16.08% 83.92% 55.44% 2.78% 25.70%
765 17.48% 82.52% 54.67% 2.73% 25.12% 821 16.07% 83.94% 55.45% 2.78% 25.71%
766 17.45% 82.55% 54.69% 2.73% 25.14% 822 16.03% 83.97% 55.46% 2.78% 25.72%
767 17.43% 82.58% 54.70% 2.73% 25.15% 823 16.01% 83.99% 55.48% 2.79% 25.73%
768 17.40% 82.60% 54.72% 2.73% 25.15% 824 15.99% 84.01% 55.49% 2.79% 25.73%
769 17.38% 82.63% 54.74% 2.73% 25.16% 825 15.97% 84.04% 55.50% 2.79% 25.74%
770 17.35% 82.65% 54.76% 2.73% 25.17% 826 15.95% 84.06% 55.51% 2.79% 25.76%
771 17.33% 82.67% 54.76% 2.73% 25.18% 827 15.92% 84.08% 55.53% 2.79% 25.77%
772 17.30% 82.70% 54.78% 2.73% 25.19% 828 15.89% 84.11% 55.54% 2.79% 25.78%
773 17.27% 82.73% 54.80% 2.73% 25.21% 829 15.87% 84.14% 55.56% 2.79% 25.79%
774 17.24% 82.76% 54.81% 2.73% 25.22% 830 15.83% 84.17% 55.57% 2.79% 25.81%
775 17.21% 82.79% 54.83% 2.73% 25.23% 831 15.80% 84.20% 55.59% 2.79% 25.82%
776 17.18% 82.82% 54.85% 2.73% 25.24% 832 15.78% 84.22% 55.60% 2.79% 25.83%
777 17.16% 82.84% 54.86% 2.73% 25.25% 833 15.75% 84.25% 55.62% 2.79% 25.84%
778 17.14% 82.86% 54.87% 2.73% 25.26% 834 15.74% 84.26% 55.63% 2.79% 25.85%
779 17.11% 82.89% 54.88% 2.74% 25.28% 835 15.71% 84.29% 55.63% 2.80% 25.86%
780 17.09% 82.91% 54.89% 2.74% 25.29% 836 15.69% 84.31% 55.65% 2.80% 25.87%
781 17.07% 82.93% 54.90% 2.74% 25.30% 837 15.67% 84.34% 55.66% 2.80% 25.88%
782 17.04% 82.96% 54.92% 2.74% 25.31% 838 15.63% 84.37% 55.67% 2.80% 25.89%
783 17.02% 82.98% 54.93% 2.74% 25.32% 839 15.61% 84.39% 55.69% 2.80% 25.91%
784 17.00% 83.00% 54.94% 2.74% 25.32% 840 15.59% 84.42% 55.70% 2.80% 25.92%
785 16.98% 83.03% 54.96% 2.74% 25.33% 841 15.56% 84.44% 55.71% 2.80% 25.93%
786 16.95% 83.05% 54.97% 2.74% 25.34% 842 15.55% 84.45% 55.72% 2.80% 25.94%
787 16.92% 83.08% 54.99% 2.74% 25.35% 843 15.52% 84.48% 55.73% 2.80% 25.95%
788 16.91% 83.09% 55.00% 2.74% 25.35% 844 15.50% 84.50% 55.74% 2.80% 25.96%
789 16.88% 83.12% 55.02% 2.74% 25.36% 845 15.47% 84.53% 55.75% 2.81% 25.98%
790 16.85% 83.15% 55.03% 2.75% 25.38% 846 15.45% 84.55% 55.76% 2.81% 25.99%
791 16.82% 83.18% 55.05% 2.75% 25.39% 847 15.42% 84.58% 55.78% 2.81% 26.00%
792 16.79% 83.21% 55.06% 2.75% 25.41% 848 15.39% 84.61% 55.79% 2.81% 26.02%
793 16.76% 83.24% 55.08% 2.75% 25.41% 849 15.37% 84.63% 55.80% 2.81% 26.02%
794 16.73% 83.27% 55.09% 2.75% 25.43% 850 15.35% 84.65% 55.81% 2.81% 26.03%
795 16.70% 83.30% 55.11% 2.75% 25.44% 851 15.32% 84.68% 55.82% 2.81% 26.04%
796 16.67% 83.33% 55.12% 2.75% 25.45% 852 15.31% 84.69% 55.83% 2.81% 26.05%
797 16.65% 83.35% 55.14% 2.75% 25.46% 853 15.28% 84.72% 55.85% 2.81% 26.06%
798 16.62% 83.38% 55.16% 2.76% 25.47% 854 15.25% 84.75% 55.86% 2.81% 26.08%
799 16.59% 83.41% 55.17% 2.76% 25.48% 855 15.24% 84.77% 55.86% 2.82% 26.09%
800 16.56% 83.44% 55.19% 2.76% 25.49% 856 15.21% 84.79% 55.88% 2.82% 26.10%
801 16.54% 83.46% 55.20% 2.76% 25.50% 857 15.19% 84.81% 55.89% 2.82% 26.11%
802 16.51% 83.49% 55.22% 2.76% 25.51% 858 15.16% 84.84% 55.90% 2.82% 26.12%
803 16.48% 83.52% 55.23% 2.76% 25.53% 859 15.13% 84.87% 55.92% 2.82% 26.13%
804 16.46% 83.54% 55.24% 2.76% 25.53% 860 15.10% 84.90% 55.94% 2.82% 26.15%
805 16.45% 83.56% 55.25% 2.76% 25.54% 861 15.08% 84.93% 55.95% 2.82% 26.16%
158
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 862 15.06% 84.94% 55.96% 2.82% 26.17% 918 13.88% 86.12% 56.57% 2.87% 26.68%
863 15.04% 84.96% 55.96% 2.82% 26.17% 919 13.86% 86.14% 56.58% 2.87% 26.69%
864 15.02% 84.98% 55.98% 2.82% 26.18% 920 13.84% 86.16% 56.59% 2.88% 26.70%
865 15.00% 85.00% 55.99% 2.83% 26.19% 921 13.82% 86.18% 56.60% 2.88% 26.71%
866 14.97% 85.03% 56.00% 2.83% 26.21% 922 13.80% 86.20% 56.61% 2.88% 26.71%
867 14.95% 85.05% 56.01% 2.83% 26.22% 923 13.78% 86.22% 56.62% 2.88% 26.72%
868 14.92% 85.08% 56.02% 2.83% 26.23% 924 13.76% 86.24% 56.63% 2.88% 26.73%
869 14.90% 85.10% 56.03% 2.83% 26.24% 925 13.73% 86.27% 56.65% 2.88% 26.74%
870 14.87% 85.14% 56.05% 2.83% 26.26% 926 13.71% 86.29% 56.66% 2.88% 26.75%
871 14.84% 85.16% 56.06% 2.83% 26.26% 927 13.69% 86.31% 56.67% 2.88% 26.76%
872 14.82% 85.18% 56.07% 2.83% 26.28% 928 13.67% 86.34% 56.69% 2.88% 26.77%
873 14.81% 85.19% 56.08% 2.83% 26.28% 929 13.65% 86.35% 56.70% 2.88% 26.77%
874 14.78% 85.22% 56.10% 2.83% 26.29% 930 13.62% 86.38% 56.72% 2.88% 26.78%
875 14.76% 85.24% 56.10% 2.83% 26.30% 931 13.59% 86.41% 56.73% 2.88% 26.80%
876 14.74% 85.26% 56.12% 2.83% 26.31% 932 13.58% 86.42% 56.74% 2.88% 26.80%
877 14.72% 85.29% 56.13% 2.83% 26.33% 933 13.56% 86.44% 56.75% 2.88% 26.81%
878 14.69% 85.31% 56.14% 2.83% 26.33% 934 13.53% 86.47% 56.77% 2.89% 26.82%
879 14.67% 85.33% 56.15% 2.84% 26.34% 935 13.51% 86.49% 56.78% 2.89% 26.83%
880 14.65% 85.36% 56.16% 2.84% 26.35% 936 13.49% 86.51% 56.79% 2.89% 26.83%
881 14.62% 85.38% 56.18% 2.84% 26.36% 937 13.47% 86.53% 56.81% 2.89% 26.84%
882 14.60% 85.40% 56.19% 2.84% 26.37% 938 13.44% 86.56% 56.81% 2.89% 26.85%
883 14.58% 85.42% 56.20% 2.84% 26.38% 939 13.42% 86.58% 56.82% 2.89% 26.86%
884 14.56% 85.44% 56.21% 2.84% 26.39% 940 13.41% 86.59% 56.83% 2.89% 26.86%
885 14.54% 85.46% 56.22% 2.84% 26.40% 941 13.40% 86.60% 56.84% 2.89% 26.87%
886 14.52% 85.49% 56.24% 2.84% 26.41% 942 13.38% 86.62% 56.85% 2.90% 26.87%
887 14.50% 85.50% 56.25% 2.84% 26.42% 943 13.37% 86.64% 56.86% 2.90% 26.88%
888 14.47% 85.53% 56.26% 2.85% 26.42% 944 13.35% 86.65% 56.87% 2.90% 26.88%
889 14.44% 85.56% 56.28% 2.85% 26.43% 945 13.33% 86.67% 56.88% 2.90% 26.89%
890 14.42% 85.58% 56.30% 2.85% 26.44% 946 13.31% 86.69% 56.89% 2.90% 26.90%
891 14.40% 85.60% 56.31% 2.85% 26.44% 947 13.30% 86.70% 56.90% 2.90% 26.91%
892 14.38% 85.62% 56.32% 2.85% 26.45% 948 13.28% 86.72% 56.91% 2.90% 26.91%
893 14.37% 85.64% 56.32% 2.85% 26.46% 949 13.25% 86.75% 56.93% 2.90% 26.93%
894 14.35% 85.65% 56.33% 2.85% 26.47% 950 13.24% 86.76% 56.93% 2.90% 26.93%
895 14.33% 85.67% 56.34% 2.85% 26.48% 951 13.22% 86.78% 56.94% 2.90% 26.94%
896 14.31% 85.69% 56.36% 2.85% 26.48% 952 13.20% 86.80% 56.95% 2.90% 26.95%
897 14.29% 85.71% 56.37% 2.85% 26.49% 953 13.18% 86.82% 56.96% 2.90% 26.96%
898 14.27% 85.73% 56.37% 2.85% 26.51% 954 13.16% 86.84% 56.97% 2.90% 26.97%
899 14.24% 85.76% 56.39% 2.85% 26.52% 955 13.14% 86.86% 56.99% 2.90% 26.97%
900 14.23% 85.77% 56.39% 2.85% 26.52% 956 13.12% 86.88% 57.00% 2.90% 26.98%
901 14.21% 85.79% 56.40% 2.86% 26.53% 957 13.09% 86.91% 57.01% 2.90% 26.99%
902 14.19% 85.81% 56.42% 2.86% 26.54% 958 13.07% 86.93% 57.02% 2.90% 27.01%
903 14.17% 85.83% 56.43% 2.86% 26.55% 959 13.05% 86.95% 57.03% 2.90% 27.01%
904 14.15% 85.85% 56.44% 2.86% 26.55% 960 13.04% 86.96% 57.04% 2.90% 27.02%
905 14.13% 85.87% 56.45% 2.86% 26.57% 961 13.02% 86.98% 57.05% 2.90% 27.03%
906 14.11% 85.90% 56.46% 2.86% 26.57% 962 13.01% 86.99% 57.06% 2.90% 27.04%
907 14.09% 85.91% 56.46% 2.86% 26.58% 963 12.99% 87.01% 57.07% 2.90% 27.04%
908 14.07% 85.93% 56.48% 2.86% 26.59% 964 12.97% 87.03% 57.07% 2.90% 27.05%
909 14.05% 85.95% 56.49% 2.86% 26.60% 965 12.96% 87.05% 57.08% 2.90% 27.06%
910 14.03% 85.98% 56.50% 2.87% 26.61% 966 12.94% 87.06% 57.09% 2.91% 27.07%
911 14.01% 85.99% 56.50% 2.87% 26.62% 967 12.91% 87.09% 57.10% 2.91% 27.08%
912 13.99% 86.01% 56.52% 2.87% 26.63% 968 12.90% 87.10% 57.11% 2.91% 27.08%
913 13.98% 86.03% 56.52% 2.87% 26.63% 969 12.88% 87.12% 57.12% 2.91% 27.09%
914 13.95% 86.05% 56.54% 2.87% 26.64% 970 12.87% 87.13% 57.13% 2.91% 27.09%
915 13.94% 86.06% 56.55% 2.87% 26.65% 971 12.86% 87.14% 57.13% 2.91% 27.10%
916 13.92% 86.08% 56.56% 2.87% 26.66% 972 12.85% 87.15% 57.14% 2.91% 27.10%
917 13.90% 86.10% 56.56% 2.87% 26.66% 973 12.83% 87.17% 57.15% 2.91% 27.11%
159
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 974 12.81% 87.19% 57.16% 2.91% 27.12% 1030 11.83% 88.17% 57.68% 2.96% 27.53%
975 12.80% 87.20% 57.17% 2.92% 27.12% 1031 11.82% 88.18% 57.69% 2.96% 27.54%
976 12.77% 87.23% 57.18% 2.92% 27.13% 1032 11.80% 88.20% 57.70% 2.96% 27.54%
977 12.75% 87.25% 57.19% 2.92% 27.14% 1033 11.79% 88.21% 57.71% 2.96% 27.55%
978 12.74% 87.26% 57.19% 2.92% 27.15% 1034 11.78% 88.22% 57.71% 2.96% 27.55%
979 12.72% 87.28% 57.20% 2.92% 27.16% 1035 11.75% 88.25% 57.73% 2.96% 27.56%
980 12.70% 87.30% 57.21% 2.92% 27.17% 1036 11.73% 88.27% 57.73% 2.96% 27.57%
981 12.68% 87.32% 57.22% 2.92% 27.18% 1037 11.72% 88.28% 57.74% 2.96% 27.58%
982 12.67% 87.33% 57.23% 2.92% 27.18% 1038 11.70% 88.30% 57.75% 2.96% 27.59%
983 12.64% 87.36% 57.25% 2.92% 27.19% 1039 11.68% 88.32% 57.76% 2.96% 27.60%
984 12.63% 87.37% 57.25% 2.92% 27.20% 1040 11.66% 88.34% 57.77% 2.96% 27.60%
985 12.61% 87.39% 57.26% 2.92% 27.20% 1041 11.65% 88.35% 57.78% 2.97% 27.61%
986 12.59% 87.42% 57.27% 2.92% 27.22% 1042 11.63% 88.37% 57.79% 2.97% 27.62%
987 12.56% 87.44% 57.29% 2.92% 27.23% 1043 11.60% 88.40% 57.81% 2.97% 27.63%
988 12.55% 87.45% 57.29% 2.93% 27.23% 1044 11.58% 88.42% 57.81% 2.97% 27.64%
989 12.54% 87.46% 57.30% 2.93% 27.24% 1045 11.57% 88.43% 57.82% 2.97% 27.64%
990 12.51% 87.49% 57.31% 2.93% 27.25% 1046 11.56% 88.44% 57.82% 2.97% 27.65%
991 12.49% 87.51% 57.32% 2.93% 27.26% 1047 11.54% 88.47% 57.84% 2.97% 27.66%
992 12.47% 87.53% 57.33% 2.93% 27.27% 1048 11.52% 88.48% 57.84% 2.97% 27.67%
993 12.45% 87.55% 57.35% 2.93% 27.27% 1049 11.51% 88.50% 57.85% 2.97% 27.67%
994 12.43% 87.57% 57.36% 2.93% 27.28% 1050 11.49% 88.52% 57.86% 2.97% 27.68%
995 12.41% 87.59% 57.37% 2.93% 27.29% 1051 11.47% 88.53% 57.87% 2.97% 27.69%
996 12.39% 87.61% 57.38% 2.93% 27.30% 1052 11.45% 88.55% 57.88% 2.97% 27.70%
997 12.37% 87.63% 57.39% 2.93% 27.31% 1053 11.44% 88.56% 57.88% 2.97% 27.71%
998 12.36% 87.65% 57.39% 2.93% 27.32% 1054 11.42% 88.58% 57.89% 2.97% 27.72%
999 12.33% 87.67% 57.41% 2.93% 27.33% 1055 11.41% 88.59% 57.90% 2.97% 27.72%
1000 12.31% 87.69% 57.42% 2.93% 27.34% 1056 11.39% 88.61% 57.91% 2.97% 27.73%
1001 12.30% 87.70% 57.43% 2.93% 27.34% 1057 11.38% 88.62% 57.92% 2.97% 27.73%
1002 12.29% 87.71% 57.43% 2.94% 27.34% 1058 11.37% 88.63% 57.92% 2.98% 27.74%
1003 12.27% 87.73% 57.44% 2.94% 27.35% 1059 11.35% 88.65% 57.93% 2.98% 27.74%
1004 12.26% 87.74% 57.45% 2.94% 27.36% 1060 11.33% 88.67% 57.94% 2.98% 27.75%
1005 12.25% 87.75% 57.46% 2.94% 27.36% 1061 11.32% 88.68% 57.95% 2.98% 27.76%
1006 12.22% 87.78% 57.47% 2.94% 27.37% 1062 11.31% 88.69% 57.96% 2.98% 27.76%
1007 12.20% 87.80% 57.48% 2.94% 27.37% 1063 11.30% 88.70% 57.96% 2.98% 27.76%
1008 12.18% 87.82% 57.49% 2.94% 27.39% 1064 11.29% 88.71% 57.96% 2.98% 27.77%
1009 12.17% 87.83% 57.50% 2.94% 27.39% 1065 11.28% 88.72% 57.97% 2.98% 27.78%
1010 12.15% 87.85% 57.52% 2.94% 27.40% 1066 11.26% 88.74% 57.98% 2.98% 27.78%
1011 12.13% 87.87% 57.52% 2.94% 27.41% 1067 11.24% 88.76% 57.99% 2.98% 27.79%
1012 12.10% 87.90% 57.53% 2.94% 27.42% 1068 11.23% 88.77% 57.99% 2.98% 27.79%
1013 12.09% 87.92% 57.54% 2.94% 27.43% 1069 11.22% 88.78% 58.00% 2.98% 27.80%
1014 12.08% 87.92% 57.55% 2.94% 27.43% 1070 11.20% 88.80% 58.01% 2.98% 27.80%
1015 12.06% 87.94% 57.55% 2.94% 27.44% 1071 11.19% 88.81% 58.02% 2.98% 27.81%
1016 12.04% 87.96% 57.57% 2.94% 27.45% 1072 11.18% 88.82% 58.02% 2.98% 27.81%
1017 12.02% 87.98% 57.58% 2.94% 27.46% 1073 11.16% 88.84% 58.04% 2.98% 27.82%
1018 12.01% 87.99% 57.59% 2.94% 27.46% 1074 11.15% 88.85% 58.04% 2.99% 27.83%
1019 11.99% 88.01% 57.60% 2.95% 27.47% 1075 11.14% 88.86% 58.04% 2.99% 27.83%
1020 11.98% 88.02% 57.60% 2.95% 27.47% 1076 11.13% 88.87% 58.04% 2.99% 27.84%
1021 11.97% 88.03% 57.61% 2.95% 27.48% 1077 11.12% 88.88% 58.05% 2.99% 27.85%
1022 11.96% 88.04% 57.61% 2.95% 27.48% 1078 11.10% 88.90% 58.05% 2.99% 27.85%
1023 11.95% 88.05% 57.62% 2.95% 27.49% 1079 11.09% 88.91% 58.06% 2.99% 27.86%
1024 11.93% 88.07% 57.63% 2.95% 27.49% 1080 11.07% 88.93% 58.08% 2.99% 27.87%
1025 11.91% 88.09% 57.64% 2.95% 27.50% 1081 11.05% 88.95% 58.08% 2.99% 27.87%
1026 11.90% 88.10% 57.65% 2.95% 27.50% 1082 11.04% 88.96% 58.09% 2.99% 27.88%
1027 11.88% 88.12% 57.66% 2.95% 27.51% 1083 11.02% 88.98% 58.10% 2.99% 27.88%
1028 11.86% 88.14% 57.67% 2.95% 27.52% 1084 11.01% 88.99% 58.11% 2.99% 27.89%
1029 11.85% 88.15% 57.67% 2.95% 27.52% 1085 11.00% 89.00% 58.11% 2.99% 27.89%
160
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 1086 10.99% 89.01% 58.12% 2.99% 27.90% 1142 10.19% 89.81% 58.53% 3.03% 28.26%
1087 10.98% 89.03% 58.13% 2.99% 27.90% 1143 10.18% 89.82% 58.53% 3.03% 28.27%
1088 10.96% 89.04% 58.14% 2.99% 27.91% 1144 10.16% 89.84% 58.54% 3.03% 28.27%
1089 10.95% 89.05% 58.15% 3.00% 27.91% 1145 10.15% 89.85% 58.55% 3.03% 28.28%
1090 10.94% 89.06% 58.15% 3.00% 27.92% 1146 10.13% 89.87% 58.56% 3.03% 28.28%
1091 10.93% 89.07% 58.16% 3.00% 27.92% 1147 10.12% 89.88% 58.56% 3.03% 28.29%
1092 10.92% 89.08% 58.16% 3.00% 27.93% 1148 10.11% 89.89% 58.57% 3.03% 28.29%
1093 10.91% 89.10% 58.17% 3.00% 27.93% 1149 10.10% 89.90% 58.58% 3.03% 28.30%
1094 10.89% 89.12% 58.17% 3.00% 27.94% 1150 10.09% 89.91% 58.58% 3.03% 28.30%
1095 10.87% 89.13% 58.18% 3.00% 27.96% 1151 10.08% 89.92% 58.59% 3.03% 28.31%
1096 10.85% 89.15% 58.19% 3.00% 27.97% 1152 10.07% 89.93% 58.59% 3.03% 28.31%
1097 10.84% 89.16% 58.19% 3.00% 27.97% 1153 10.05% 89.95% 58.60% 3.03% 28.33%
1098 10.82% 89.18% 58.20% 3.00% 27.98% 1154 10.04% 89.97% 58.60% 3.03% 28.33%
1099 10.80% 89.20% 58.21% 3.00% 27.99% 1155 10.02% 89.98% 58.61% 3.03% 28.33%
1100 10.79% 89.21% 58.22% 3.00% 27.99% 1156 10.01% 89.99% 58.62% 3.03% 28.34%
1101 10.78% 89.22% 58.22% 3.00% 28.00% 1157 9.99% 90.01% 58.63% 3.04% 28.35%
1102 10.76% 89.24% 58.23% 3.01% 28.01% 1158 9.97% 90.03% 58.63% 3.04% 28.36%
1103 10.74% 89.26% 58.24% 3.01% 28.02% 1159 9.95% 90.05% 58.64% 3.04% 28.37%
1104 10.72% 89.28% 58.25% 3.01% 28.03% 1160 9.94% 90.06% 58.65% 3.04% 28.37%
1105 10.71% 89.29% 58.25% 3.01% 28.03% 1161 9.92% 90.08% 58.66% 3.04% 28.38%
1106 10.69% 89.31% 58.26% 3.01% 28.05% 1162 9.91% 90.09% 58.67% 3.04% 28.39%
1107 10.68% 89.32% 58.26% 3.01% 28.05% 1163 9.90% 90.10% 58.68% 3.04% 28.39%
1108 10.66% 89.34% 58.27% 3.01% 28.06% 1164 9.89% 90.11% 58.68% 3.04% 28.40%
1109 10.65% 89.35% 58.28% 3.01% 28.06% 1165 9.87% 90.13% 58.69% 3.04% 28.41%
1110 10.63% 89.37% 58.29% 3.01% 28.07% 1166 9.85% 90.15% 58.69% 3.04% 28.42%
1111 10.61% 89.39% 58.29% 3.01% 28.08% 1167 9.84% 90.16% 58.70% 3.04% 28.42%
1112 10.60% 89.40% 58.30% 3.01% 28.09% 1168 9.83% 90.17% 58.70% 3.04% 28.43%
1113 10.59% 89.41% 58.30% 3.01% 28.09% 1169 9.82% 90.19% 58.71% 3.04% 28.44%
1114 10.58% 89.42% 58.32% 3.01% 28.10% 1170 9.81% 90.19% 58.72% 3.04% 28.44%
1115 10.55% 89.45% 58.33% 3.01% 28.10% 1171 9.79% 90.21% 58.72% 3.04% 28.44%
1116 10.54% 89.46% 58.34% 3.01% 28.11% 1172 9.78% 90.22% 58.73% 3.04% 28.45%
1117 10.53% 89.47% 58.35% 3.01% 28.12% 1173 9.77% 90.23% 58.73% 3.04% 28.45%
1118 10.51% 89.49% 58.35% 3.01% 28.12% 1174 9.76% 90.24% 58.74% 3.04% 28.46%
1119 10.50% 89.50% 58.36% 3.01% 28.13% 1175 9.75% 90.25% 58.75% 3.04% 28.46%
1120 10.49% 89.51% 58.37% 3.02% 28.13% 1176 9.74% 90.26% 58.75% 3.04% 28.47%
1121 10.48% 89.52% 58.37% 3.02% 28.13% 1177 9.73% 90.27% 58.75% 3.04% 28.48%
1122 10.47% 89.53% 58.37% 3.02% 28.14% 1178 9.72% 90.28% 58.76% 3.04% 28.48%
1123 10.44% 89.56% 58.39% 3.02% 28.15% 1179 9.71% 90.29% 58.76% 3.04% 28.49%
1124 10.43% 89.58% 58.40% 3.02% 28.16% 1180 9.69% 90.31% 58.77% 3.04% 28.50%
1125 10.41% 89.59% 58.40% 3.02% 28.17% 1181 9.68% 90.32% 58.77% 3.04% 28.51%
1126 10.40% 89.60% 58.40% 3.02% 28.18% 1182 9.67% 90.33% 58.78% 3.04% 28.51%
1127 10.39% 89.62% 58.41% 3.02% 28.19% 1183 9.66% 90.34% 58.78% 3.04% 28.52%
1128 10.37% 89.63% 58.42% 3.02% 28.19% 1184 9.64% 90.36% 58.79% 3.04% 28.52%
1129 10.36% 89.64% 58.43% 3.02% 28.19% 1185 9.63% 90.37% 58.79% 3.04% 28.53%
1130 10.35% 89.65% 58.44% 3.02% 28.20% 1186 9.62% 90.38% 58.80% 3.04% 28.54%
1131 10.34% 89.66% 58.44% 3.02% 28.20% 1187 9.61% 90.39% 58.81% 3.04% 28.54%
1132 10.32% 89.68% 58.45% 3.02% 28.21% 1188 9.60% 90.40% 58.81% 3.04% 28.55%
1133 10.31% 89.69% 58.46% 3.02% 28.21% 1189 9.59% 90.41% 58.82% 3.05% 28.55%
1134 10.29% 89.71% 58.46% 3.02% 28.22% 1190 9.58% 90.42% 58.82% 3.05% 28.55%
1135 10.28% 89.72% 58.47% 3.02% 28.22% 1191 9.57% 90.43% 58.83% 3.05% 28.56%
1136 10.27% 89.73% 58.48% 3.02% 28.23% 1192 9.56% 90.44% 58.83% 3.05% 28.56%
1137 10.26% 89.75% 58.49% 3.02% 28.23% 1193 9.55% 90.45% 58.84% 3.05% 28.57%
1138 10.24% 89.76% 58.50% 3.03% 28.24% 1194 9.54% 90.46% 58.85% 3.05% 28.57%
1139 10.23% 89.77% 58.51% 3.03% 28.24% 1195 9.53% 90.47% 58.85% 3.05% 28.57%
1140 10.22% 89.78% 58.51% 3.03% 28.25% 1196 9.51% 90.49% 58.85% 3.05% 28.58%
1141 10.20% 89.80% 58.52% 3.03% 28.25% 1197 9.50% 90.50% 58.86% 3.05% 28.59%
161
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 1198 9.49% 90.52% 58.87% 3.05% 28.60%
1199 9.48% 90.52% 58.87% 3.05% 28.60%
1200 9.46% 90.54% 58.88% 3.05% 28.61%
162
Table B3. LOCA Probability History for ASP-02 Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA for Days After TOD -312 98.61% 1.39% 0.38% 1.01% 0.00%
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA -311 98.61% 1.39% 0.38% 1.01% 0.00%
-365 99.06% 0.94% 0.21% 0.73% 0.00% -310 98.60% 1.40% 0.39% 1.02% 0.00%
-364 99.05% 0.96% 0.22% 0.74% 0.00% -309 98.58% 1.42% 0.40% 1.02% 0.00%
-363 99.04% 0.96% 0.22% 0.74% 0.00% -308 98.57% 1.43% 0.40% 1.03% 0.00%
-362 99.03% 0.97% 0.23% 0.74% 0.00% -307 98.56% 1.44% 0.40% 1.04% 0.00%
-361 99.02% 0.98% 0.23% 0.75% 0.00% -306 98.55% 1.45% 0.41% 1.05% 0.00%
-360 99.02% 0.98% 0.23% 0.76% 0.00% -305 98.54% 1.46% 0.41% 1.06% 0.00%
-359 99.01% 0.99% 0.23% 0.76% 0.00% -304 98.53% 1.47% 0.41% 1.06% 0.00%
-358 99.00% 1.00% 0.23% 0.77% 0.00% -303 98.51% 1.49% 0.41% 1.07% 0.00%
-357 98.99% 1.01% 0.24% 0.77% 0.00% -302 98.51% 1.49% 0.42% 1.08% 0.00%
-356 98.99% 1.02% 0.24% 0.78% 0.00% -301 98.49% 1.51% 0.42% 1.09% 0.00%
-355 98.98% 1.02% 0.24% 0.78% 0.00% -300 98.48% 1.52% 0.43% 1.10% 0.00%
-354 98.97% 1.03% 0.25% 0.78% 0.00% -299 98.46% 1.54% 0.44% 1.10% 0.00%
-353 98.96% 1.04% 0.25% 0.79% 0.00% -298 98.46% 1.55% 0.44% 1.11% 0.00%
-352 98.96% 1.04% 0.25% 0.79% 0.00% -297 98.44% 1.56% 0.44% 1.12% 0.00%
-351 98.96% 1.04% 0.25% 0.79% 0.00% -296 98.43% 1.57% 0.45% 1.12% 0.00%
-350 98.95% 1.05% 0.26% 0.80% 0.00% -295 98.42% 1.58% 0.45% 1.13% 0.00%
-349 98.94% 1.06% 0.26% 0.80% 0.00% -294 98.41% 1.60% 0.46% 1.14% 0.00%
-348 98.93% 1.07% 0.26% 0.81% 0.00% -293 98.40% 1.60% 0.46% 1.14% 0.00%
-347 98.92% 1.08% 0.27% 0.81% 0.00% -292 98.38% 1.62% 0.47% 1.15% 0.00%
-346 98.91% 1.09% 0.27% 0.82% 0.00% -291 98.37% 1.63% 0.47% 1.16% 0.00%
-345 98.90% 1.10% 0.28% 0.83% 0.00% -290 98.36% 1.65% 0.48% 1.17% 0.00%
-344 98.90% 1.11% 0.28% 0.83% 0.00% -289 98.34% 1.66% 0.49% 1.17% 0.00%
-343 98.89% 1.11% 0.28% 0.83% 0.00% -288 98.33% 1.67% 0.49% 1.18% 0.00%
-342 98.88% 1.12% 0.28% 0.84% 0.00% -287 98.31% 1.69% 0.50% 1.19% 0.00%
-341 98.87% 1.13% 0.29% 0.84% 0.00% -286 98.29% 1.71% 0.51% 1.20% 0.00%
-340 98.87% 1.13% 0.29% 0.84% 0.00% -285 98.29% 1.71% 0.51% 1.20% 0.00%
-339 98.86% 1.14% 0.29% 0.85% 0.00% -284 98.27% 1.73% 0.52% 1.21% 0.00%
-338 98.85% 1.15% 0.29% 0.86% 0.00% -283 98.26% 1.75% 0.52% 1.22% 0.00%
-337 98.83% 1.17% 0.30% 0.86% 0.00% -282 98.23% 1.77% 0.53% 1.23% 0.00%
-336 98.82% 1.18% 0.31% 0.87% 0.00% -281 98.22% 1.78% 0.54% 1.24% 0.00%
-335 98.82% 1.18% 0.31% 0.87% 0.00% -280 98.21% 1.79% 0.54% 1.25% 0.00%
-334 98.81% 1.19% 0.31% 0.88% 0.00% -279 98.20% 1.80% 0.55% 1.25% 0.00%
-333 98.79% 1.21% 0.32% 0.89% 0.00% -278 98.19% 1.82% 0.56% 1.26% 0.00%
-332 98.79% 1.21% 0.32% 0.90% 0.00% -277 98.16% 1.84% 0.57% 1.27% 0.00%
-331 98.78% 1.22% 0.32% 0.90% 0.00% -276 98.15% 1.85% 0.58% 1.28% 0.00%
-330 98.77% 1.23% 0.32% 0.91% 0.00% -275 98.14% 1.86% 0.58% 1.28% 0.00%
-329 98.76% 1.24% 0.32% 0.91% 0.00% -274 98.12% 1.88% 0.58% 1.30% 0.00%
-328 98.76% 1.24% 0.33% 0.92% 0.00% -273 98.11% 1.89% 0.59% 1.31% 0.00%
-327 98.74% 1.26% 0.33% 0.92% 0.00% -272 98.10% 1.90% 0.59% 1.31% 0.00%
-326 98.74% 1.26% 0.33% 0.93% 0.00% -271 98.08% 1.92% 0.60% 1.32% 0.00%
-325 98.73% 1.27% 0.34% 0.93% 0.00% -270 98.06% 1.94% 0.60% 1.34% 0.00%
-324 98.72% 1.28% 0.34% 0.94% 0.00% -269 98.05% 1.95% 0.61% 1.35% 0.00%
-323 98.71% 1.29% 0.35% 0.94% 0.00% -268 98.03% 1.97% 0.61% 1.35% 0.00%
-322 98.70% 1.31% 0.35% 0.95% 0.00% -267 98.02% 1.98% 0.62% 1.36% 0.00%
-321 98.69% 1.31% 0.36% 0.96% 0.00% -266 98.00% 2.00% 0.63% 1.37% 0.00%
-320 98.67% 1.33% 0.36% 0.97% 0.00% -265 98.00% 2.01% 0.63% 1.37% 0.00%
-319 98.67% 1.33% 0.36% 0.97% 0.00% -264 97.99% 2.01% 0.63% 1.38% 0.00%
-318 98.66% 1.34% 0.37% 0.97% 0.00% -263 97.97% 2.03% 0.64% 1.39% 0.00%
-317 98.66% 1.35% 0.37% 0.98% 0.00% -262 97.96% 2.04% 0.65% 1.40% 0.00%
-316 98.64% 1.36% 0.37% 0.98% 0.00% -261 97.94% 2.06% 0.65% 1.41% 0.00%
-315 98.64% 1.36% 0.38% 0.99% 0.00% -260 97.93% 2.07% 0.66% 1.41% 0.00%
-314 98.63% 1.37% 0.38% 0.99% 0.00% -259 97.92% 2.08% 0.67% 1.42% 0.00%
-313 98.62% 1.38% 0.38% 1.00% 0.00% -258 97.91% 2.10% 0.67% 1.43% 0.00%
163
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA
-257 97.89% 2.11% 0.68% 1.43% 0.00% -202 96.66% 3.34% 1.24% 2.10% 0.00%
-256 97.87% 2.13% 0.69% 1.44% 0.00% -201 96.63% 3.37% 1.26% 2.11% 0.00%
-255 97.86% 2.14% 0.69% 1.45% 0.00% -200 96.60% 3.40% 1.28% 2.12% 0.00%
-254 97.84% 2.16% 0.70% 1.45% 0.00% -199 96.57% 3.43% 1.29% 2.14% 0.00%
-253 97.83% 2.17% 0.71% 1.47% 0.00% -198 96.54% 3.46% 1.30% 2.16% 0.00%
-252 97.81% 2.19% 0.72% 1.47% 0.00% -197 96.51% 3.49% 1.31% 2.18% 0.00%
-251 97.79% 2.21% 0.73% 1.48% 0.00% -196 96.48% 3.52% 1.32% 2.20% 0.00%
-250 97.77% 2.23% 0.74% 1.49% 0.00% -195 96.45% 3.55% 1.34% 2.21% 0.00%
-249 97.76% 2.24% 0.75% 1.50% 0.00% -194 96.42% 3.58% 1.36% 2.23% 0.00%
-248 97.73% 2.27% 0.75% 1.52% 0.00% -193 96.38% 3.62% 1.37% 2.24% 0.00%
-247 97.71% 2.29% 0.76% 1.53% 0.00% -192 96.36% 3.64% 1.39% 2.25% 0.00%
-246 97.69% 2.31% 0.77% 1.54% 0.00% -191 96.33% 3.67% 1.41% 2.27% 0.00%
-245 97.67% 2.33% 0.78% 1.55% 0.00% -190 96.29% 3.71% 1.43% 2.28% 0.00%
-244 97.65% 2.35% 0.78% 1.56% 0.00% -189 96.25% 3.75% 1.44% 2.30% 0.00%
-243 97.63% 2.37% 0.79% 1.58% 0.00% -188 96.22% 3.78% 1.46% 2.33% 0.00%
-242 97.61% 2.39% 0.80% 1.59% 0.00% -187 96.18% 3.82% 1.47% 2.35% 0.00%
-241 97.59% 2.41% 0.81% 1.60% 0.00% -186 96.15% 3.85% 1.49% 2.36% 0.00%
-240 97.57% 2.43% 0.81% 1.61% 0.00% -185 96.13% 3.87% 1.50% 2.37% 0.00%
-239 97.57% 2.44% 0.82% 1.62% 0.00% -184 96.10% 3.90% 1.52% 2.39% 0.00%
-238 97.53% 2.47% 0.83% 1.64% 0.00% -183 96.05% 3.95% 1.54% 2.41% 0.00%
-237 97.51% 2.49% 0.84% 1.65% 0.00% -182 96.02% 3.98% 1.56% 2.43% 0.00%
-236 97.49% 2.51% 0.85% 1.66% 0.00% -181 95.97% 4.03% 1.58% 2.45% 0.00%
-235 97.47% 2.53% 0.86% 1.67% 0.00% -180 95.93% 4.07% 1.60% 2.47% 0.00%
-234 97.45% 2.55% 0.87% 1.68% 0.00% -179 95.90% 4.10% 1.62% 2.49% 0.00%
-233 97.43% 2.58% 0.88% 1.70% 0.00% -178 95.86% 4.14% 1.63% 2.51% 0.00%
-232 97.40% 2.60% 0.88% 1.72% 0.00% -177 95.83% 4.18% 1.65% 2.53% 0.00%
-231 97.38% 2.62% 0.89% 1.73% 0.00% -176 95.79% 4.21% 1.67% 2.54% 0.00%
-230 97.36% 2.64% 0.90% 1.74% 0.00% -175 95.75% 4.26% 1.69% 2.57% 0.00%
-229 97.33% 2.67% 0.92% 1.75% 0.00% -174 95.70% 4.30% 1.70% 2.59% 0.00%
-228 97.30% 2.70% 0.93% 1.77% 0.00% -173 95.67% 4.33% 1.72% 2.62% 0.00%
-227 97.29% 2.71% 0.94% 1.78% 0.00% -172 95.62% 4.39% 1.74% 2.64% 0.00%
-226 97.26% 2.74% 0.95% 1.79% 0.00% -171 95.59% 4.42% 1.76% 2.66% 0.00%
-225 97.24% 2.76% 0.96% 1.80% 0.00% -170 95.55% 4.46% 1.78% 2.67% 0.00%
-224 97.21% 2.79% 0.98% 1.81% 0.00% -169 95.51% 4.49% 1.80% 2.69% 0.00%
-223 97.19% 2.81% 0.98% 1.82% 0.00% -168 95.48% 4.53% 1.82% 2.70% 0.00%
-222 97.17% 2.83% 0.99% 1.84% 0.00% -167 95.43% 4.57% 1.84% 2.73% 0.00%
-221 97.15% 2.85% 1.00% 1.85% 0.00% -166 95.39% 4.61% 1.86% 2.75% 0.00%
-220 97.13% 2.87% 1.01% 1.86% 0.00% -165 95.36% 4.64% 1.87% 2.77% 0.00%
-219 97.11% 2.89% 1.02% 1.87% 0.00% -164 95.32% 4.69% 1.89% 2.79% 0.00%
-218 97.09% 2.92% 1.03% 1.89% 0.00% -163 95.28% 4.72% 1.91% 2.81% 0.00%
-217 97.06% 2.94% 1.04% 1.90% 0.00% -162 95.26% 4.74% 1.92% 2.83% 0.00%
-216 97.03% 2.97% 1.05% 1.92% 0.00% -161 95.20% 4.80% 1.94% 2.86% 0.00%
-215 97.00% 3.00% 1.07% 1.93% 0.00% -160 95.17% 4.83% 1.96% 2.87% 0.00%
-214 96.99% 3.01% 1.07% 1.94% 0.00% -159 95.14% 4.86% 1.97% 2.89% 0.00%
-213 96.95% 3.05% 1.09% 1.96% 0.00% -158 95.11% 4.89% 1.99% 2.91% 0.00%
-212 96.93% 3.07% 1.09% 1.97% 0.00% -157 95.07% 4.93% 2.01% 2.92% 0.00%
-211 96.92% 3.09% 1.11% 1.98% 0.00% -156 95.03% 4.97% 2.03% 2.95% 0.00%
-210 96.89% 3.11% 1.12% 2.00% 0.00% -155 94.99% 5.01% 2.04% 2.97% 0.00%
-209 96.85% 3.15% 1.14% 2.01% 0.00% -154 94.96% 5.04% 2.06% 2.98% 0.00%
-208 96.82% 3.18% 1.15% 2.03% 0.00% -153 94.92% 5.08% 2.08% 3.00% 0.00%
-207 96.80% 3.20% 1.17% 2.03% 0.00% -152 94.86% 5.14% 2.11% 3.03% 0.00%
-206 96.77% 3.23% 1.18% 2.05% 0.00% -151 94.82% 5.18% 2.13% 3.05% 0.00%
-205 96.75% 3.25% 1.19% 2.06% 0.00% -150 94.79% 5.21% 2.15% 3.06% 0.00%
-204 96.73% 3.27% 1.20% 2.07% 0.00% -149 94.75% 5.26% 2.17% 3.09% 0.00%
-203 96.69% 3.31% 1.22% 2.09% 0.00% -148 94.72% 5.28% 2.18% 3.10% 0.00%
164
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA
-147 94.67% 5.33% 2.21% 3.12% 0.00% -92 91.52% 8.48% 3.75% 4.73% 0.00%
-146 94.63% 5.37% 2.22% 3.15% 0.00% -91 91.46% 8.54% 3.78% 4.76% 0.00%
-145 94.59% 5.41% 2.25% 3.17% 0.00% -90 91.38% 8.62% 3.81% 4.80% 0.00%
-144 94.55% 5.45% 2.27% 3.19% 0.00% -89 91.31% 8.69% 3.85% 4.84% 0.00%
-143 94.50% 5.50% 2.29% 3.21% 0.00% -88 91.24% 8.76% 3.89% 4.87% 0.00%
-142 94.45% 5.55% 2.31% 3.24% 0.00% -87 91.18% 8.82% 3.92% 4.90% 0.00%
-141 94.42% 5.58% 2.33% 3.26% 0.00% -86 91.11% 8.89% 3.95% 4.94% 0.00%
-140 94.37% 5.63% 2.36% 3.28% 0.00% -85 91.05% 8.95% 3.98% 4.97% 0.00%
-139 94.31% 5.69% 2.38% 3.30% 0.00% -84 90.98% 9.02% 4.02% 5.00% 0.00%
-138 94.27% 5.73% 2.41% 3.33% 0.00% -83 90.91% 9.09% 4.04% 5.05% 0.00%
-137 94.22% 5.78% 2.42% 3.36% 0.00% -82 90.84% 9.16% 4.07% 5.09% 0.00%
-136 94.17% 5.83% 2.45% 3.38% 0.00% -81 90.78% 9.22% 4.10% 5.12% 0.00%
-135 94.13% 5.88% 2.47% 3.40% 0.00% -80 90.72% 9.29% 4.13% 5.15% 0.00%
-134 94.07% 5.93% 2.50% 3.43% 0.00% -79 90.65% 9.35% 4.16% 5.19% 0.00%
-133 94.01% 5.99% 2.53% 3.46% 0.00% -78 90.58% 9.43% 4.20% 5.22% 0.00%
-132 93.97% 6.03% 2.55% 3.48% 0.00% -77 90.51% 9.49% 4.24% 5.25% 0.00%
-131 93.92% 6.08% 2.58% 3.51% 0.00% -76 90.44% 9.57% 4.28% 5.28% 0.00%
-130 93.88% 6.13% 2.59% 3.53% 0.00% -75 90.36% 9.64% 4.31% 5.32% 0.00%
-129 93.83% 6.17% 2.62% 3.56% 0.00% -74 90.28% 9.72% 4.35% 5.37% 0.00%
-128 93.77% 6.23% 2.65% 3.58% 0.00% -73 90.20% 9.80% 4.40% 5.40% 0.00%
-127 93.72% 6.28% 2.68% 3.60% 0.00% -72 90.11% 9.89% 4.45% 5.44% 0.00%
-126 93.66% 6.34% 2.70% 3.63% 0.00% -71 90.03% 9.97% 4.48% 5.48% 0.00%
-125 93.62% 6.38% 2.73% 3.65% 0.00% -70 89.96% 10.04% 4.51% 5.53% 0.00%
-124 93.56% 6.44% 2.75% 3.68% 0.00% -69 89.88% 10.12% 4.55% 5.57% 0.00%
-123 93.52% 6.48% 2.77% 3.71% 0.00% -68 89.82% 10.18% 4.57% 5.61% 0.00%
-122 93.48% 6.52% 2.79% 3.73% 0.00% -67 89.74% 10.26% 4.61% 5.65% 0.00%
-121 93.43% 6.57% 2.81% 3.76% 0.00% -66 89.65% 10.35% 4.65% 5.70% 0.00%
-120 93.37% 6.63% 2.84% 3.79% 0.00% -65 89.56% 10.44% 4.69% 5.75% 0.00%
-119 93.30% 6.70% 2.87% 3.83% 0.00% -64 89.47% 10.53% 4.73% 5.79% 0.00%
-118 93.22% 6.78% 2.91% 3.87% 0.00% -63 89.38% 10.62% 4.77% 5.85% 0.00%
-117 93.16% 6.84% 2.94% 3.90% 0.00% -62 89.28% 10.72% 4.81% 5.90% 0.00%
-116 93.09% 6.91% 2.97% 3.95% 0.00% -61 89.20% 10.80% 4.85% 5.94% 0.01%
-115 93.01% 6.99% 3.00% 3.98% 0.00% -60 89.11% 10.89% 4.90% 5.99% 0.01%
-114 92.95% 7.05% 3.03% 4.02% 0.00% -59 89.03% 10.97% 4.93% 6.03% 0.01%
-113 92.90% 7.11% 3.06% 4.05% 0.00% -58 88.94% 11.06% 4.98% 6.08% 0.01%
-112 92.83% 7.17% 3.09% 4.08% 0.00% -57 88.85% 11.15% 5.02% 6.13% 0.01%
-111 92.76% 7.24% 3.12% 4.12% 0.00% -56 88.75% 11.25% 5.07% 6.17% 0.01%
-110 92.70% 7.30% 3.16% 4.14% 0.00% -55 88.66% 11.34% 5.11% 6.23% 0.01%
-109 92.64% 7.37% 3.19% 4.17% 0.00% -54 88.57% 11.43% 5.15% 6.27% 0.01%
-108 92.57% 7.43% 3.23% 4.20% 0.00% -53 88.47% 11.53% 5.20% 6.33% 0.01%
-107 92.51% 7.49% 3.26% 4.23% 0.00% -52 88.39% 11.61% 5.23% 6.38% 0.01%
-106 92.46% 7.54% 3.28% 4.25% 0.00% -51 88.28% 11.72% 5.27% 6.44% 0.01%
-105 92.40% 7.60% 3.31% 4.29% 0.00% -50 88.20% 11.80% 5.30% 6.49% 0.01%
-104 92.35% 7.66% 3.34% 4.31% 0.00% -49 88.11% 11.89% 5.35% 6.53% 0.01%
-103 92.28% 7.72% 3.37% 4.34% 0.00% -48 88.03% 11.97% 5.39% 6.57% 0.01%
-102 92.21% 7.79% 3.41% 4.38% 0.00% -47 87.93% 12.07% 5.44% 6.62% 0.01%
-101 92.14% 7.86% 3.45% 4.41% 0.00% -46 87.84% 12.16% 5.48% 6.67% 0.01%
-100 92.07% 7.93% 3.49% 4.44% 0.00% -45 87.73% 12.27% 5.52% 6.74% 0.01%
-99 92.01% 7.99% 3.52% 4.47% 0.00% -44 87.65% 12.35% 5.55% 6.79% 0.01%
-98 91.94% 8.06% 3.55% 4.51% 0.00% -43 87.54% 12.46% 5.60% 6.85% 0.01%
-97 91.85% 8.15% 3.60% 4.56% 0.00% -42 87.43% 12.57% 5.65% 6.91% 0.01%
-96 91.79% 8.21% 3.63% 4.58% 0.00% -41 87.36% 12.64% 5.68% 6.95% 0.01%
-95 91.72% 8.28% 3.66% 4.62% 0.00% -40 87.28% 12.72% 5.72% 6.99% 0.01%
-94 91.65% 8.35% 3.69% 4.66% 0.00% -39 87.18% 12.82% 5.76% 7.04% 0.02%
-93 91.58% 8.42% 3.73% 4.69% 0.00% -38 87.08% 12.92% 5.80% 7.10% 0.02%
165
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA
-37 87.00% 13.00% 5.83% 7.16% 0.02% 18 80.54% 19.46% 8.30% 11.00% 0.15%
-36 86.90% 13.10% 5.88% 7.21% 0.02% 19 80.39% 19.61% 8.36% 11.09% 0.16%
-35 86.80% 13.20% 5.92% 7.27% 0.02% 20 80.25% 19.75% 8.41% 11.17% 0.17%
-34 86.70% 13.30% 5.95% 7.33% 0.02% 21 80.11% 19.89% 8.46% 11.26% 0.18%
-33 86.61% 13.39% 6.00% 7.38% 0.02% 22 79.98% 20.02% 8.51% 11.33% 0.18%
-32 86.54% 13.46% 6.03% 7.42% 0.02% 23 79.84% 20.16% 8.56% 11.41% 0.20%
-31 86.44% 13.56% 6.06% 7.48% 0.02% 24 79.70% 20.30% 8.60% 11.50% 0.20%
-30 86.34% 13.66% 6.10% 7.55% 0.02% 25 79.55% 20.45% 8.65% 11.59% 0.21%
-29 86.25% 13.75% 6.14% 7.59% 0.02% 26 79.44% 20.56% 8.69% 11.67% 0.21%
-28 86.15% 13.85% 6.19% 7.64% 0.02% 27 79.28% 20.72% 8.75% 11.75% 0.22%
-27 86.05% 13.95% 6.23% 7.70% 0.02% 28 79.14% 20.86% 8.80% 11.83% 0.23%
-26 85.96% 14.04% 6.27% 7.75% 0.02% 29 79.02% 20.98% 8.84% 11.90% 0.24%
-25 85.86% 14.14% 6.31% 7.82% 0.02% 30 78.90% 21.10% 8.89% 11.97% 0.24%
-24 85.77% 14.23% 6.35% 7.86% 0.02% 31 78.77% 21.23% 8.94% 12.04% 0.25%
-23 85.67% 14.34% 6.40% 7.92% 0.02% 32 78.65% 21.35% 8.99% 12.11% 0.26%
-22 85.55% 14.45% 6.45% 7.98% 0.02% 33 78.51% 21.49% 9.04% 12.19% 0.26%
-21 85.45% 14.55% 6.49% 8.04% 0.02% 34 78.40% 21.60% 9.08% 12.25% 0.27%
-20 85.34% 14.66% 6.54% 8.09% 0.02% 35 78.28% 21.72% 9.12% 12.33% 0.28%
-19 85.23% 14.77% 6.59% 8.15% 0.02% 36 78.13% 21.87% 9.17% 12.42% 0.28%
-18 85.14% 14.86% 6.63% 8.21% 0.02% 37 77.98% 22.02% 9.22% 12.50% 0.30%
-17 85.05% 14.95% 6.67% 8.25% 0.02% 38 77.86% 22.14% 9.27% 12.57% 0.30%
-16 84.94% 15.06% 6.73% 8.31% 0.02% 39 77.73% 22.28% 9.32% 12.65% 0.31%
-15 84.83% 15.17% 6.79% 8.36% 0.02% 40 77.59% 22.41% 9.36% 12.73% 0.32%
-14 84.73% 15.27% 6.82% 8.43% 0.02% 41 77.45% 22.55% 9.42% 12.81% 0.32%
-13 84.63% 15.37% 6.85% 8.49% 0.03% 42 77.30% 22.70% 9.48% 12.90% 0.33%
-12 84.52% 15.48% 6.91% 8.55% 0.03% 43 77.16% 22.84% 9.52% 12.98% 0.34%
-11 84.39% 15.61% 6.96% 8.63% 0.03% 44 77.04% 22.97% 9.58% 13.05% 0.34%
-10 84.28% 15.73% 7.00% 8.69% 0.03% 45 76.90% 23.10% 9.63% 13.12% 0.35%
-9 84.17% 15.83% 7.05% 8.75% 0.03% 46 76.77% 23.23% 9.67% 13.20% 0.36%
-8 84.04% 15.96% 7.10% 8.83% 0.03% 47 76.66% 23.34% 9.72% 13.27% 0.36%
-7 83.94% 16.06% 7.14% 8.89% 0.03% 48 76.53% 23.47% 9.76% 13.34% 0.37%
-6 83.81% 16.19% 7.19% 8.97% 0.03% 49 76.38% 23.62% 9.81% 13.44% 0.38%
-5 83.69% 16.31% 7.24% 9.04% 0.04% 50 76.25% 23.75% 9.85% 13.52% 0.38%
-4 83.58% 16.42% 7.28% 9.10% 0.04% 51 76.12% 23.88% 9.89% 13.60% 0.39%
-3 83.47% 16.53% 7.31% 9.18% 0.04% 52 75.98% 24.02% 9.95% 13.68% 0.39%
-2 83.35% 16.66% 7.36% 9.25% 0.04% 53 75.87% 24.13% 9.99% 13.74% 0.40%
-1 83.22% 16.79% 7.41% 9.34% 0.04% 54 75.74% 24.26% 10.04% 13.82% 0.40%
0 82.88% 17.12% 7.45% 9.62% 0.05% 55 75.62% 24.38% 10.09% 13.89% 0.40%
1 82.74% 17.26% 7.50% 9.71% 0.05% 56 75.50% 24.50% 10.14% 13.95% 0.41%
2 82.57% 17.43% 7.54% 9.83% 0.06% 57 75.37% 24.64% 10.21% 14.02% 0.41%
3 82.44% 17.56% 7.59% 9.91% 0.06% 58 75.24% 24.76% 10.26% 14.08% 0.42%
4 82.30% 17.70% 7.63% 10.00% 0.07% 59 75.11% 24.89% 10.32% 14.16% 0.42%
5 82.18% 17.82% 7.68% 10.07% 0.08% 60 74.98% 25.02% 10.37% 14.23% 0.43%
6 82.06% 17.94% 7.72% 10.13% 0.09% 61 74.84% 25.16% 10.43% 14.31% 0.43%
7 81.94% 18.06% 7.77% 10.21% 0.09% 62 74.71% 25.29% 10.48% 14.38% 0.44%
8 81.81% 18.19% 7.81% 10.28% 0.10% 63 74.58% 25.42% 10.52% 14.46% 0.44%
9 81.70% 18.30% 7.85% 10.35% 0.10% 64 74.44% 25.56% 10.57% 14.55% 0.44%
10 81.58% 18.42% 7.90% 10.42% 0.11% 65 74.31% 25.69% 10.62% 14.62% 0.45%
11 81.43% 18.57% 7.95% 10.50% 0.12% 66 74.17% 25.83% 10.67% 14.70% 0.45%
12 81.31% 18.69% 8.00% 10.57% 0.12% 67 74.04% 25.96% 10.72% 14.78% 0.46%
13 81.18% 18.82% 8.06% 10.63% 0.13% 68 73.92% 26.08% 10.76% 14.85% 0.47%
14 81.07% 18.93% 8.11% 10.69% 0.13% 69 73.79% 26.21% 10.81% 14.93% 0.47%
15 80.93% 19.07% 8.17% 10.77% 0.14% 70 73.65% 26.35% 10.86% 15.01% 0.48%
16 80.80% 19.20% 8.21% 10.84% 0.14% 71 73.50% 26.50% 10.93% 15.09% 0.48%
17 80.68% 19.32% 8.25% 10.92% 0.14% 72 73.34% 26.66% 10.98% 15.19% 0.49%
166
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 73 73.21% 26.79% 11.04% 15.27% 0.49% 128 65.55% 34.45% 13.91% 19.70% 0.85%
74 73.06% 26.94% 11.10% 15.35% 0.49% 129 65.42% 34.58% 13.96% 19.77% 0.85%
75 72.94% 27.06% 11.14% 15.43% 0.50% 130 65.25% 34.75% 14.02% 19.87% 0.87%
76 72.80% 27.20% 11.20% 15.50% 0.50% 131 65.13% 34.87% 14.06% 19.94% 0.88%
77 72.66% 27.34% 11.24% 15.60% 0.51% 132 65.00% 35.00% 14.10% 20.01% 0.88%
78 72.54% 27.47% 11.28% 15.67% 0.51% 133 64.86% 35.14% 14.15% 20.10% 0.89%
79 72.39% 27.61% 11.34% 15.76% 0.52% 134 64.72% 35.28% 14.21% 20.17% 0.91%
80 72.25% 27.75% 11.38% 15.85% 0.52% 135 64.58% 35.42% 14.27% 20.25% 0.91%
81 72.10% 27.90% 11.44% 15.93% 0.53% 136 64.45% 35.55% 14.31% 20.33% 0.92%
82 71.95% 28.05% 11.49% 16.02% 0.54% 137 64.32% 35.68% 14.37% 20.38% 0.93%
83 71.82% 28.18% 11.55% 16.10% 0.54% 138 64.18% 35.82% 14.43% 20.46% 0.93%
84 71.68% 28.32% 11.61% 16.16% 0.54% 139 64.05% 35.95% 14.48% 20.53% 0.94%
85 71.55% 28.45% 11.67% 16.23% 0.55% 140 63.92% 36.08% 14.53% 20.60% 0.95%
86 71.43% 28.57% 11.71% 16.30% 0.56% 141 63.78% 36.22% 14.59% 20.67% 0.96%
87 71.29% 28.71% 11.76% 16.39% 0.57% 142 63.64% 36.36% 14.64% 20.75% 0.97%
88 71.15% 28.85% 11.81% 16.46% 0.57% 143 63.49% 36.51% 14.68% 20.85% 0.98%
89 71.01% 28.99% 11.86% 16.55% 0.58% 144 63.35% 36.65% 14.73% 20.94% 0.99%
90 70.88% 29.12% 11.91% 16.63% 0.58% 145 63.21% 36.79% 14.77% 21.01% 1.01%
91 70.75% 29.25% 11.96% 16.71% 0.58% 146 63.06% 36.94% 14.83% 21.09% 1.02%
92 70.60% 29.40% 12.03% 16.78% 0.59% 147 62.94% 37.06% 14.86% 21.17% 1.03%
93 70.48% 29.53% 12.07% 16.86% 0.60% 148 62.79% 37.21% 14.90% 21.25% 1.06%
94 70.35% 29.65% 12.13% 16.93% 0.60% 149 62.67% 37.33% 14.95% 21.31% 1.07%
95 70.21% 29.79% 12.18% 17.00% 0.61% 150 62.55% 37.45% 14.99% 21.39% 1.08%
96 70.08% 29.93% 12.24% 17.08% 0.61% 151 62.43% 37.57% 15.03% 21.45% 1.09%
97 69.94% 30.06% 12.28% 17.17% 0.61% 152 62.29% 37.71% 15.08% 21.53% 1.11%
98 69.80% 30.20% 12.34% 17.24% 0.62% 153 62.15% 37.85% 15.12% 21.61% 1.12%
99 69.67% 30.33% 12.39% 17.32% 0.63% 154 62.00% 38.00% 15.18% 21.69% 1.14%
100 69.53% 30.47% 12.44% 17.39% 0.63% 155 61.85% 38.15% 15.22% 21.78% 1.15%
101 69.39% 30.61% 12.49% 17.48% 0.64% 156 61.74% 38.26% 15.26% 21.84% 1.16%
102 69.26% 30.74% 12.54% 17.56% 0.64% 157 61.60% 38.40% 15.31% 21.92% 1.17%
103 69.12% 30.88% 12.59% 17.64% 0.65% 158 61.45% 38.55% 15.36% 22.02% 1.18%
104 68.98% 31.02% 12.65% 17.71% 0.66% 159 61.33% 38.67% 15.41% 22.07% 1.19%
105 68.85% 31.15% 12.71% 17.78% 0.66% 160 61.21% 38.79% 15.45% 22.14% 1.21%
106 68.70% 31.30% 12.77% 17.86% 0.67% 161 61.10% 38.90% 15.50% 22.19% 1.21%
107 68.58% 31.42% 12.81% 17.94% 0.68% 162 60.99% 39.01% 15.53% 22.26% 1.22%
108 68.44% 31.56% 12.86% 18.01% 0.68% 163 60.87% 39.13% 15.58% 22.33% 1.22%
109 68.28% 31.72% 12.93% 18.11% 0.68% 164 60.74% 39.26% 15.63% 22.40% 1.24%
110 68.13% 31.87% 12.98% 18.20% 0.69% 165 60.62% 39.38% 15.67% 22.46% 1.25%
111 68.00% 32.00% 13.03% 18.28% 0.70% 166 60.50% 39.50% 15.71% 22.53% 1.26%
112 67.84% 32.16% 13.08% 18.37% 0.71% 167 60.37% 39.63% 15.76% 22.60% 1.28%
113 67.68% 32.32% 13.14% 18.47% 0.72% 168 60.25% 39.75% 15.79% 22.67% 1.29%
114 67.51% 32.49% 13.19% 18.58% 0.72% 169 60.14% 39.87% 15.85% 22.73% 1.29%
115 67.36% 32.64% 13.24% 18.66% 0.73% 170 60.03% 39.97% 15.88% 22.79% 1.30%
116 67.24% 32.77% 13.29% 18.73% 0.74% 171 59.91% 40.10% 15.92% 22.86% 1.32%
117 67.08% 32.92% 13.34% 18.82% 0.76% 172 59.78% 40.22% 15.96% 22.93% 1.33%
118 66.93% 33.07% 13.40% 18.91% 0.77% 173 59.66% 40.34% 16.01% 23.00% 1.34%
119 66.78% 33.22% 13.44% 19.00% 0.78% 174 59.53% 40.47% 16.05% 23.07% 1.35%
120 66.61% 33.39% 13.51% 19.09% 0.79% 175 59.38% 40.62% 16.10% 23.15% 1.36%
121 66.48% 33.52% 13.56% 19.17% 0.79% 176 59.26% 40.74% 16.15% 23.21% 1.38%
122 66.35% 33.65% 13.60% 19.25% 0.80% 177 59.15% 40.85% 16.20% 23.26% 1.39%
123 66.22% 33.78% 13.66% 19.32% 0.81% 178 59.04% 40.96% 16.24% 23.32% 1.40%
124 66.08% 33.92% 13.71% 19.39% 0.82% 179 58.92% 41.08% 16.28% 23.39% 1.41%
125 65.96% 34.05% 13.76% 19.47% 0.82% 180 58.80% 41.20% 16.33% 23.45% 1.42%
126 65.82% 34.18% 13.81% 19.54% 0.83% 181 58.67% 41.33% 16.38% 23.52% 1.43%
127 65.69% 34.31% 13.85% 19.62% 0.84% 182 58.55% 41.45% 16.43% 23.58% 1.44%
167
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 183 58.42% 41.58% 16.47% 23.65% 1.46% 238 52.33% 47.67% 18.60% 26.96% 2.11%
184 58.28% 41.72% 16.52% 23.73% 1.48% 239 52.25% 47.75% 18.63% 27.01% 2.12%
185 58.17% 41.83% 16.55% 23.79% 1.49% 240 52.13% 47.87% 18.67% 27.08% 2.13%
186 58.06% 41.94% 16.60% 23.85% 1.50% 241 52.03% 47.97% 18.70% 27.13% 2.14%
187 57.95% 42.05% 16.63% 23.92% 1.51% 242 51.94% 48.06% 18.74% 27.17% 2.15%
188 57.83% 42.17% 16.67% 23.98% 1.52% 243 51.84% 48.16% 18.78% 27.22% 2.16%
189 57.71% 42.29% 16.72% 24.04% 1.54% 244 51.73% 48.27% 18.82% 27.28% 2.17%
190 57.59% 42.41% 16.75% 24.10% 1.56% 245 51.65% 48.35% 18.85% 27.33% 2.18%
191 57.48% 42.52% 16.79% 24.17% 1.57% 246 51.55% 48.46% 18.90% 27.37% 2.19%
192 57.37% 42.63% 16.82% 24.23% 1.58% 247 51.42% 48.59% 18.94% 27.44% 2.21%
193 57.26% 42.74% 16.86% 24.29% 1.59% 248 51.31% 48.69% 18.98% 27.50% 2.21%
194 57.15% 42.85% 16.90% 24.34% 1.61% 249 51.22% 48.78% 19.00% 27.56% 2.22%
195 57.02% 42.98% 16.95% 24.42% 1.62% 250 51.10% 48.90% 19.05% 27.61% 2.24%
196 56.90% 43.11% 17.00% 24.49% 1.63% 251 50.98% 49.02% 19.10% 27.68% 2.25%
197 56.76% 43.25% 17.04% 24.56% 1.65% 252 50.88% 49.12% 19.13% 27.74% 2.26%
198 56.65% 43.35% 17.08% 24.61% 1.66% 253 50.80% 49.20% 19.16% 27.78% 2.26%
199 56.54% 43.46% 17.12% 24.68% 1.67% 254 50.71% 49.29% 19.19% 27.84% 2.27%
200 56.43% 43.57% 17.16% 24.74% 1.68% 255 50.60% 49.40% 19.21% 27.90% 2.28%
201 56.30% 43.70% 17.20% 24.81% 1.69% 256 50.50% 49.50% 19.24% 27.96% 2.30%
202 56.19% 43.81% 17.24% 24.87% 1.70% 257 50.39% 49.61% 19.28% 28.02% 2.31%
203 56.11% 43.90% 17.26% 24.93% 1.71% 258 50.29% 49.71% 19.31% 28.08% 2.32%
204 55.99% 44.01% 17.29% 25.00% 1.72% 259 50.19% 49.81% 19.34% 28.13% 2.34%
205 55.89% 44.11% 17.33% 25.05% 1.73% 260 50.10% 49.90% 19.36% 28.18% 2.36%
206 55.76% 44.25% 17.38% 25.12% 1.75% 261 49.99% 50.01% 19.41% 28.24% 2.37%
207 55.64% 44.36% 17.43% 25.17% 1.76% 262 49.89% 50.11% 19.45% 28.28% 2.38%
208 55.53% 44.47% 17.47% 25.24% 1.77% 263 49.79% 50.21% 19.49% 28.33% 2.39%
209 55.41% 44.59% 17.51% 25.30% 1.78% 264 49.71% 50.29% 19.52% 28.37% 2.40%
210 55.29% 44.71% 17.55% 25.37% 1.79% 265 49.61% 50.40% 19.56% 28.42% 2.42%
211 55.16% 44.84% 17.59% 25.44% 1.81% 266 49.50% 50.50% 19.59% 28.48% 2.43%
212 55.05% 44.95% 17.63% 25.50% 1.82% 267 49.40% 50.60% 19.63% 28.53% 2.43%
213 54.94% 45.06% 17.67% 25.55% 1.83% 268 49.31% 50.69% 19.65% 28.59% 2.44%
214 54.85% 45.16% 17.71% 25.60% 1.84% 269 49.21% 50.79% 19.69% 28.64% 2.45%
215 54.74% 45.26% 17.76% 25.65% 1.85% 270 49.12% 50.88% 19.72% 28.69% 2.46%
216 54.62% 45.38% 17.81% 25.72% 1.86% 271 49.03% 50.97% 19.76% 28.74% 2.48%
217 54.50% 45.50% 17.84% 25.79% 1.88% 272 48.95% 51.05% 19.78% 28.78% 2.49%
218 54.41% 45.59% 17.86% 25.85% 1.89% 273 48.88% 51.13% 19.80% 28.82% 2.50%
219 54.30% 45.70% 17.91% 25.90% 1.90% 274 48.77% 51.23% 19.84% 28.87% 2.52%
220 54.17% 45.83% 17.96% 25.96% 1.91% 275 48.67% 51.33% 19.88% 28.92% 2.53%
221 54.07% 45.93% 18.00% 26.01% 1.92% 276 48.57% 51.43% 19.91% 28.98% 2.54%
222 53.97% 46.03% 18.03% 26.07% 1.93% 277 48.48% 51.52% 19.95% 29.03% 2.55%
223 53.88% 46.13% 18.07% 26.11% 1.95% 278 48.39% 51.61% 19.98% 29.07% 2.56%
224 53.77% 46.24% 18.11% 26.17% 1.96% 279 48.29% 51.71% 20.02% 29.13% 2.57%
225 53.67% 46.33% 18.14% 26.23% 1.97% 280 48.21% 51.80% 20.05% 29.17% 2.58%
226 53.57% 46.44% 18.18% 26.28% 1.98% 281 48.10% 51.90% 20.09% 29.22% 2.59%
227 53.47% 46.53% 18.20% 26.34% 1.99% 282 48.01% 51.99% 20.12% 29.27% 2.60%
228 53.36% 46.64% 18.24% 26.41% 2.00% 283 47.93% 52.07% 20.15% 29.31% 2.61%
229 53.26% 46.74% 18.27% 26.45% 2.01% 284 47.85% 52.15% 20.19% 29.34% 2.62%
230 53.15% 46.85% 18.31% 26.52% 2.02% 285 47.76% 52.25% 20.22% 29.39% 2.63%
231 53.06% 46.94% 18.34% 26.57% 2.04% 286 47.66% 52.34% 20.26% 29.44% 2.65%
232 52.97% 47.03% 18.37% 26.62% 2.04% 287 47.56% 52.44% 20.30% 29.49% 2.65%
233 52.84% 47.16% 18.42% 26.68% 2.06% 288 47.45% 52.55% 20.33% 29.56% 2.67%
234 52.73% 47.27% 18.46% 26.74% 2.07% 289 47.33% 52.67% 20.37% 29.62% 2.68%
235 52.65% 47.35% 18.48% 26.79% 2.08% 290 47.25% 52.75% 20.40% 29.67% 2.69%
236 52.55% 47.45% 18.52% 26.85% 2.08% 291 47.17% 52.83% 20.43% 29.71% 2.70%
237 52.43% 47.57% 18.57% 26.90% 2.10% 292 47.07% 52.93% 20.47% 29.76% 2.71%
168
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 293 46.99% 53.01% 20.49% 29.80% 2.72% 348 42.49% 57.51% 22.06% 32.20% 3.25%
294 46.91% 53.10% 20.52% 29.85% 2.72% 349 42.42% 57.58% 22.09% 32.23% 3.26%
295 46.81% 53.19% 20.56% 29.90% 2.73% 350 42.33% 57.67% 22.11% 32.29% 3.27%
296 46.74% 53.26% 20.58% 29.94% 2.74% 351 42.24% 57.76% 22.15% 32.33% 3.28%
297 46.66% 53.34% 20.61% 29.98% 2.75% 352 42.17% 57.83% 22.17% 32.37% 3.29%
298 46.57% 53.43% 20.64% 30.01% 2.77% 353 42.11% 57.89% 22.20% 32.40% 3.29%
299 46.49% 53.51% 20.67% 30.06% 2.78% 354 42.03% 57.97% 22.22% 32.45% 3.31%
300 46.40% 53.61% 20.71% 30.11% 2.79% 355 41.93% 58.07% 22.25% 32.50% 3.32%
301 46.32% 53.69% 20.73% 30.15% 2.80% 356 41.86% 58.14% 22.27% 32.55% 3.32%
302 46.23% 53.77% 20.75% 30.20% 2.82% 357 41.79% 58.21% 22.29% 32.59% 3.33%
303 46.13% 53.87% 20.78% 30.27% 2.83% 358 41.72% 58.28% 22.32% 32.62% 3.34%
304 46.04% 53.96% 20.81% 30.31% 2.84% 359 41.65% 58.35% 22.34% 32.66% 3.35%
305 45.96% 54.04% 20.84% 30.35% 2.85% 360 41.58% 58.42% 22.37% 32.70% 3.36%
306 45.89% 54.11% 20.87% 30.39% 2.85% 361 41.50% 58.50% 22.39% 32.74% 3.37%
307 45.80% 54.20% 20.91% 30.44% 2.86% 362 41.44% 58.56% 22.42% 32.77% 3.37%
308 45.71% 54.29% 20.94% 30.48% 2.87% 363 41.38% 58.62% 22.45% 32.80% 3.38%
309 45.63% 54.37% 20.96% 30.53% 2.88% 364 41.30% 58.70% 22.47% 32.85% 3.39%
310 45.52% 54.48% 21.00% 30.58% 2.89% 365 41.23% 58.77% 22.49% 32.88% 3.40%
311 45.45% 54.55% 21.03% 30.62% 2.90% 366 41.16% 58.84% 22.51% 32.92% 3.41%
312 45.38% 54.62% 21.05% 30.66% 2.91% 367 41.11% 58.89% 22.53% 32.95% 3.42%
313 45.29% 54.71% 21.08% 30.71% 2.92% 368 41.04% 58.96% 22.55% 32.98% 3.43%
314 45.21% 54.79% 21.10% 30.76% 2.93% 369 40.98% 59.02% 22.58% 33.01% 3.43%
315 45.13% 54.87% 21.13% 30.81% 2.94% 370 40.90% 59.10% 22.61% 33.05% 3.44%
316 45.03% 54.97% 21.16% 30.86% 2.95% 371 40.84% 59.16% 22.63% 33.08% 3.45%
317 44.95% 55.05% 21.18% 30.91% 2.96% 372 40.77% 59.23% 22.65% 33.12% 3.46%
318 44.87% 55.13% 21.21% 30.96% 2.96% 373 40.69% 59.31% 22.68% 33.16% 3.47%
319 44.79% 55.21% 21.23% 31.00% 2.97% 374 40.63% 59.37% 22.71% 33.19% 3.48%
320 44.71% 55.29% 21.26% 31.05% 2.98% 375 40.55% 59.45% 22.73% 33.24% 3.49%
321 44.64% 55.36% 21.28% 31.08% 2.99% 376 40.49% 59.51% 22.75% 33.27% 3.49%
322 44.56% 55.44% 21.32% 31.13% 3.00% 377 40.43% 59.57% 22.77% 33.31% 3.50%
323 44.48% 55.52% 21.35% 31.17% 3.01% 378 40.35% 59.65% 22.79% 33.36% 3.50%
324 44.40% 55.60% 21.37% 31.21% 3.02% 379 40.29% 59.71% 22.81% 33.40% 3.51%
325 44.32% 55.68% 21.40% 31.25% 3.03% 380 40.22% 59.78% 22.83% 33.44% 3.51%
326 44.23% 55.77% 21.43% 31.30% 3.04% 381 40.15% 59.85% 22.86% 33.47% 3.51%
327 44.14% 55.86% 21.47% 31.35% 3.04% 382 40.08% 59.92% 22.89% 33.51% 3.52%
328 44.06% 55.94% 21.50% 31.39% 3.06% 383 40.02% 59.98% 22.90% 33.54% 3.53%
329 43.96% 56.04% 21.53% 31.44% 3.06% 384 39.96% 60.04% 22.93% 33.57% 3.54%
330 43.87% 56.13% 21.57% 31.48% 3.08% 385 39.88% 60.12% 22.96% 33.62% 3.55%
331 43.79% 56.21% 21.59% 31.52% 3.10% 386 39.84% 60.16% 22.97% 33.64% 3.55%
332 43.70% 56.30% 21.63% 31.56% 3.11% 387 39.77% 60.23% 23.00% 33.67% 3.56%
333 43.63% 56.37% 21.65% 31.61% 3.12% 388 39.69% 60.31% 23.03% 33.71% 3.57%
334 43.56% 56.44% 21.68% 31.64% 3.13% 389 39.62% 60.38% 23.06% 33.75% 3.57%
335 43.49% 56.51% 21.71% 31.67% 3.13% 390 39.54% 60.46% 23.08% 33.79% 3.58%
336 43.41% 56.59% 21.74% 31.71% 3.15% 391 39.48% 60.53% 23.11% 33.83% 3.59%
337 43.33% 56.67% 21.76% 31.75% 3.15% 392 39.40% 60.61% 23.13% 33.88% 3.59%
338 43.27% 56.73% 21.79% 31.79% 3.16% 393 39.33% 60.67% 23.16% 33.92% 3.60%
339 43.18% 56.82% 21.82% 31.83% 3.17% 394 39.26% 60.74% 23.19% 33.95% 3.61%
340 43.09% 56.91% 21.85% 31.88% 3.18% 395 39.20% 60.80% 23.21% 33.98% 3.61%
341 43.01% 56.99% 21.88% 31.91% 3.19% 396 39.14% 60.86% 23.22% 34.02% 3.62%
342 42.94% 57.06% 21.90% 31.96% 3.20% 397 39.08% 60.92% 23.25% 34.05% 3.63%
343 42.88% 57.13% 21.93% 31.99% 3.21% 398 39.01% 60.99% 23.27% 34.08% 3.64%
344 42.81% 57.19% 21.94% 32.04% 3.21% 399 38.95% 61.05% 23.29% 34.12% 3.64%
345 42.72% 57.28% 21.98% 32.09% 3.22% 400 38.89% 61.11% 23.31% 34.15% 3.65%
346 42.63% 57.37% 22.01% 32.13% 3.23% 401 38.84% 61.17% 23.34% 34.18% 3.65%
347 42.57% 57.44% 22.04% 32.16% 3.24% 402 38.77% 61.23% 23.36% 34.21% 3.66%
169
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 403 38.70% 61.31% 23.39% 34.25% 3.67% 458 35.48% 64.53% 24.57% 35.95% 4.00%
404 38.63% 61.37% 23.41% 34.29% 3.68% 459 35.43% 64.57% 24.58% 35.98% 4.01%
405 38.56% 61.44% 23.43% 34.32% 3.69% 460 35.38% 64.62% 24.61% 36.00% 4.01%
406 38.51% 61.49% 23.45% 34.35% 3.69% 461 35.32% 64.68% 24.63% 36.03% 4.02%
407 38.46% 61.54% 23.47% 34.37% 3.70% 462 35.27% 64.73% 24.64% 36.06% 4.03%
408 38.40% 61.60% 23.48% 34.41% 3.71% 463 35.22% 64.78% 24.67% 36.08% 4.03%
409 38.34% 61.66% 23.51% 34.44% 3.72% 464 35.15% 64.85% 24.69% 36.12% 4.04%
410 38.29% 61.72% 23.53% 34.47% 3.72% 465 35.09% 64.91% 24.71% 36.16% 4.04%
411 38.22% 61.78% 23.55% 34.50% 3.73% 466 35.04% 64.96% 24.73% 36.18% 4.04%
412 38.16% 61.84% 23.58% 34.54% 3.73% 467 34.97% 65.03% 24.76% 36.22% 4.05%
413 38.10% 61.91% 23.61% 34.56% 3.74% 468 34.92% 65.08% 24.77% 36.26% 4.05%
414 38.04% 61.96% 23.63% 34.59% 3.74% 469 34.87% 65.13% 24.79% 36.29% 4.06%
415 37.97% 62.03% 23.65% 34.64% 3.74% 470 34.82% 65.18% 24.81% 36.31% 4.06%
416 37.91% 62.09% 23.68% 34.66% 3.75% 471 34.76% 65.24% 24.84% 36.34% 4.07%
417 37.84% 62.16% 23.70% 34.70% 3.76% 472 34.70% 65.30% 24.86% 36.36% 4.07%
418 37.77% 62.23% 23.72% 34.74% 3.77% 473 34.65% 65.35% 24.89% 36.39% 4.07%
419 37.72% 62.28% 23.75% 34.77% 3.77% 474 34.58% 65.42% 24.91% 36.43% 4.08%
420 37.66% 62.34% 23.77% 34.79% 3.78% 475 34.53% 65.47% 24.93% 36.45% 4.09%
421 37.60% 62.40% 23.79% 34.82% 3.80% 476 34.48% 65.52% 24.95% 36.47% 4.10%
422 37.54% 62.46% 23.80% 34.86% 3.80% 477 34.43% 65.57% 24.97% 36.50% 4.10%
423 37.48% 62.52% 23.83% 34.89% 3.81% 478 34.37% 65.63% 24.99% 36.53% 4.11%
424 37.42% 62.58% 23.85% 34.92% 3.82% 479 34.32% 65.68% 25.01% 36.56% 4.11%
425 37.36% 62.64% 23.87% 34.95% 3.82% 480 34.27% 65.73% 25.03% 36.58% 4.12%
426 37.30% 62.70% 23.89% 34.98% 3.83% 481 34.22% 65.78% 25.05% 36.61% 4.12%
427 37.24% 62.76% 23.92% 35.01% 3.83% 482 34.16% 65.84% 25.06% 36.65% 4.13%
428 37.18% 62.82% 23.94% 35.04% 3.84% 483 34.11% 65.89% 25.08% 36.68% 4.13%
429 37.13% 62.88% 23.96% 35.07% 3.84% 484 34.06% 65.94% 25.09% 36.71% 4.14%
430 37.07% 62.93% 23.97% 35.11% 3.85% 485 34.01% 66.00% 25.12% 36.74% 4.14%
431 37.02% 62.98% 23.99% 35.13% 3.86% 486 33.96% 66.04% 25.13% 36.76% 4.15%
432 36.96% 63.04% 24.02% 35.16% 3.86% 487 33.90% 66.10% 25.15% 36.79% 4.15%
433 36.89% 63.11% 24.04% 35.20% 3.87% 488 33.86% 66.14% 25.17% 36.81% 4.16%
434 36.84% 63.16% 24.06% 35.23% 3.87% 489 33.81% 66.19% 25.19% 36.84% 4.16%
435 36.79% 63.21% 24.08% 35.25% 3.88% 490 33.76% 66.25% 25.21% 36.87% 4.17%
436 36.73% 63.27% 24.10% 35.28% 3.89% 491 33.70% 66.30% 25.22% 36.90% 4.18%
437 36.67% 63.33% 24.13% 35.31% 3.89% 492 33.65% 66.35% 25.24% 36.92% 4.18%
438 36.62% 63.38% 24.15% 35.34% 3.90% 493 33.61% 66.39% 25.26% 36.95% 4.19%
439 36.57% 63.43% 24.17% 35.36% 3.90% 494 33.55% 66.45% 25.28% 36.98% 4.19%
440 36.50% 63.50% 24.20% 35.39% 3.91% 495 33.50% 66.50% 25.29% 37.00% 4.20%
441 36.46% 63.55% 24.21% 35.42% 3.91% 496 33.46% 66.54% 25.32% 37.02% 4.21%
442 36.39% 63.61% 24.23% 35.46% 3.92% 497 33.41% 66.59% 25.33% 37.04% 4.22%
443 36.34% 63.66% 24.25% 35.49% 3.92% 498 33.35% 66.65% 25.36% 37.07% 4.22%
444 36.28% 63.72% 24.28% 35.51% 3.93% 499 33.30% 66.70% 25.37% 37.10% 4.23%
445 36.22% 63.78% 24.30% 35.55% 3.93% 500 33.25% 66.76% 25.39% 37.13% 4.24%
446 36.16% 63.84% 24.32% 35.58% 3.94% 501 33.19% 66.81% 25.42% 37.16% 4.24%
447 36.10% 63.90% 24.34% 35.61% 3.95% 502 33.14% 66.86% 25.44% 37.18% 4.25%
448 36.04% 63.96% 24.36% 35.64% 3.96% 503 33.07% 66.93% 25.46% 37.22% 4.25%
449 35.97% 64.03% 24.39% 35.68% 3.96% 504 33.02% 66.98% 25.47% 37.25% 4.26%
450 35.91% 64.09% 24.41% 35.71% 3.97% 505 32.97% 67.03% 25.49% 37.28% 4.26%
451 35.85% 64.15% 24.43% 35.75% 3.97% 506 32.91% 67.09% 25.52% 37.31% 4.27%
452 35.80% 64.20% 24.45% 35.77% 3.98% 507 32.87% 67.13% 25.54% 37.32% 4.27%
453 35.74% 64.26% 24.47% 35.81% 3.98% 508 32.81% 67.19% 25.55% 37.36% 4.28%
454 35.69% 64.31% 24.49% 35.84% 3.98% 509 32.75% 67.25% 25.58% 37.39% 4.28%
455 35.64% 64.36% 24.51% 35.86% 3.99% 510 32.71% 67.29% 25.60% 37.41% 4.28%
456 35.59% 64.41% 24.52% 35.90% 3.99% 511 32.66% 67.34% 25.61% 37.44% 4.29%
457 35.53% 64.48% 24.55% 35.93% 4.00% 512 32.61% 67.39% 25.62% 37.47% 4.30%
170
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 513 32.57% 67.43% 25.64% 37.49% 4.30% 568 30.06% 69.94% 26.50% 38.86% 4.58%
514 32.53% 67.47% 25.65% 37.52% 4.30% 569 30.01% 69.99% 26.52% 38.88% 4.59%
515 32.47% 67.53% 25.67% 37.55% 4.31% 570 29.98% 70.03% 26.53% 38.90% 4.59%
516 32.42% 67.58% 25.69% 37.57% 4.31% 571 29.93% 70.07% 26.55% 38.93% 4.59%
517 32.38% 67.62% 25.71% 37.60% 4.32% 572 29.90% 70.10% 26.56% 38.94% 4.60%
518 32.32% 67.68% 25.72% 37.63% 4.33% 573 29.85% 70.15% 26.58% 38.97% 4.60%
519 32.27% 67.73% 25.74% 37.67% 4.33% 574 29.81% 70.19% 26.60% 38.99% 4.60%
520 32.22% 67.78% 25.75% 37.70% 4.34% 575 29.77% 70.23% 26.62% 39.01% 4.61%
521 32.18% 67.83% 25.77% 37.71% 4.34% 576 29.72% 70.28% 26.63% 39.04% 4.61%
522 32.13% 67.87% 25.79% 37.74% 4.35% 577 29.68% 70.32% 26.65% 39.05% 4.62%
523 32.08% 67.92% 25.80% 37.77% 4.35% 578 29.63% 70.37% 26.67% 39.07% 4.63%
524 32.04% 67.96% 25.82% 37.79% 4.36% 579 29.59% 70.41% 26.68% 39.10% 4.63%
525 32.00% 68.01% 25.83% 37.82% 4.36% 580 29.55% 70.45% 26.69% 39.12% 4.64%
526 31.95% 68.05% 25.84% 37.84% 4.37% 581 29.50% 70.50% 26.72% 39.14% 4.64%
527 31.92% 68.09% 25.85% 37.87% 4.37% 582 29.46% 70.54% 26.73% 39.17% 4.64%
528 31.86% 68.14% 25.87% 37.89% 4.38% 583 29.43% 70.57% 26.74% 39.19% 4.64%
529 31.83% 68.17% 25.88% 37.92% 4.38% 584 29.38% 70.62% 26.76% 39.22% 4.65%
530 31.78% 68.22% 25.89% 37.94% 4.39% 585 29.33% 70.67% 26.77% 39.24% 4.65%
531 31.73% 68.27% 25.91% 37.97% 4.39% 586 29.29% 70.71% 26.79% 39.26% 4.66%
532 31.69% 68.31% 25.93% 37.99% 4.39% 587 29.25% 70.76% 26.81% 39.29% 4.66%
533 31.65% 68.35% 25.94% 38.01% 4.40% 588 29.20% 70.81% 26.83% 39.32% 4.66%
534 31.60% 68.40% 25.96% 38.04% 4.40% 589 29.15% 70.85% 26.85% 39.34% 4.67%
535 31.55% 68.45% 25.97% 38.07% 4.41% 590 29.11% 70.89% 26.86% 39.36% 4.67%
536 31.51% 68.49% 25.99% 38.09% 4.41% 591 29.07% 70.93% 26.88% 39.38% 4.67%
537 31.46% 68.54% 26.01% 38.12% 4.42% 592 29.02% 70.98% 26.90% 39.41% 4.68%
538 31.41% 68.59% 26.02% 38.14% 4.43% 593 28.98% 71.02% 26.91% 39.42% 4.69%
539 31.37% 68.63% 26.04% 38.16% 4.43% 594 28.93% 71.07% 26.93% 39.45% 4.69%
540 31.32% 68.68% 26.06% 38.19% 4.44% 595 28.90% 71.10% 26.94% 39.47% 4.70%
541 31.29% 68.71% 26.06% 38.21% 4.44% 596 28.87% 71.14% 26.95% 39.48% 4.70%
542 31.24% 68.76% 26.08% 38.23% 4.45% 597 28.83% 71.17% 26.96% 39.51% 4.71%
543 31.19% 68.81% 26.09% 38.27% 4.45% 598 28.79% 71.21% 26.98% 39.52% 4.71%
544 31.15% 68.86% 26.11% 38.29% 4.46% 599 28.75% 71.26% 27.00% 39.54% 4.72%
545 31.10% 68.90% 26.13% 38.31% 4.46% 600 28.70% 71.30% 27.02% 39.56% 4.72%
546 31.04% 68.96% 26.14% 38.34% 4.47% 601 28.67% 71.33% 27.02% 39.58% 4.73%
547 31.00% 69.00% 26.16% 38.37% 4.48% 602 28.64% 71.37% 27.04% 39.59% 4.73%
548 30.95% 69.05% 26.18% 38.39% 4.48% 603 28.59% 71.41% 27.06% 39.62% 4.73%
549 30.90% 69.10% 26.20% 38.42% 4.48% 604 28.56% 71.44% 27.07% 39.63% 4.74%
550 30.86% 69.14% 26.22% 38.44% 4.49% 605 28.52% 71.48% 27.09% 39.65% 4.74%
551 30.82% 69.18% 26.23% 38.46% 4.50% 606 28.48% 71.52% 27.10% 39.68% 4.74%
552 30.76% 69.24% 26.25% 38.49% 4.50% 607 28.44% 71.56% 27.11% 39.70% 4.75%
553 30.71% 69.29% 26.27% 38.51% 4.51% 608 28.40% 71.61% 27.12% 39.73% 4.75%
554 30.65% 69.35% 26.29% 38.55% 4.51% 609 28.36% 71.65% 27.14% 39.75% 4.76%
555 30.60% 69.40% 26.31% 38.57% 4.52% 610 28.32% 71.68% 27.15% 39.77% 4.76%
556 30.57% 69.43% 26.32% 38.59% 4.52% 611 28.28% 71.72% 27.16% 39.79% 4.76%
557 30.52% 69.48% 26.34% 38.61% 4.53% 612 28.24% 71.76% 27.17% 39.82% 4.77%
558 30.47% 69.53% 26.36% 38.64% 4.53% 613 28.21% 71.79% 27.17% 39.85% 4.77%
559 30.43% 69.57% 26.38% 38.66% 4.54% 614 28.16% 71.84% 27.19% 39.87% 4.78%
560 30.38% 69.62% 26.39% 38.68% 4.55% 615 28.12% 71.88% 27.21% 39.90% 4.78%
561 30.35% 69.66% 26.40% 38.70% 4.55% 616 28.08% 71.92% 27.22% 39.91% 4.78%
562 30.30% 69.70% 26.42% 38.72% 4.56% 617 28.04% 71.96% 27.24% 39.94% 4.79%
563 30.26% 69.74% 26.43% 38.74% 4.56% 618 28.00% 72.00% 27.25% 39.96% 4.79%
564 30.22% 69.78% 26.45% 38.76% 4.57% 619 27.97% 72.03% 27.26% 39.97% 4.80%
565 30.18% 69.82% 26.46% 38.79% 4.57% 620 27.93% 72.07% 27.28% 40.00% 4.80%
566 30.15% 69.86% 26.47% 38.81% 4.57% 621 27.88% 72.12% 27.29% 40.03% 4.80%
567 30.10% 69.90% 26.49% 38.83% 4.58% 622 27.85% 72.15% 27.30% 40.05% 4.81%
171
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 623 27.81% 72.19% 27.32% 40.07% 4.81% 678 25.86% 74.14% 28.00% 41.15% 4.99%
624 27.78% 72.22% 27.33% 40.08% 4.81% 679 25.83% 74.17% 28.01% 41.17% 5.00%
625 27.73% 72.27% 27.35% 40.11% 4.82% 680 25.78% 74.22% 28.03% 41.20% 5.00%
626 27.69% 72.31% 27.35% 40.13% 4.82% 681 25.75% 74.25% 28.04% 41.21% 5.00%
627 27.65% 72.35% 27.37% 40.16% 4.83% 682 25.71% 74.29% 28.06% 41.23% 5.00%
628 27.61% 72.39% 27.38% 40.18% 4.83% 683 25.68% 74.32% 28.07% 41.25% 5.01%
629 27.58% 72.42% 27.40% 40.20% 4.83% 684 25.64% 74.36% 28.08% 41.28% 5.01%
630 27.54% 72.46% 27.41% 40.22% 4.84% 685 25.62% 74.38% 28.08% 41.29% 5.01%
631 27.50% 72.50% 27.42% 40.24% 4.84% 686 25.58% 74.42% 28.10% 41.31% 5.01%
632 27.47% 72.53% 27.43% 40.26% 4.84% 687 25.54% 74.46% 28.11% 41.33% 5.02%
633 27.44% 72.56% 27.45% 40.27% 4.84% 688 25.51% 74.50% 28.12% 41.36% 5.02%
634 27.40% 72.60% 27.46% 40.29% 4.85% 689 25.47% 74.53% 28.14% 41.38% 5.02%
635 27.36% 72.64% 27.48% 40.31% 4.85% 690 25.44% 74.56% 28.15% 41.39% 5.02%
636 27.33% 72.67% 27.49% 40.32% 4.85% 691 25.41% 74.59% 28.16% 41.41% 5.02%
637 27.30% 72.70% 27.50% 40.35% 4.85% 692 25.37% 74.63% 28.18% 41.43% 5.03%
638 27.26% 72.74% 27.51% 40.37% 4.86% 693 25.34% 74.66% 28.19% 41.44% 5.03%
639 27.23% 72.77% 27.52% 40.39% 4.87% 694 25.31% 74.69% 28.19% 41.46% 5.04%
640 27.21% 72.80% 27.53% 40.40% 4.87% 695 25.28% 74.72% 28.20% 41.48% 5.04%
641 27.17% 72.83% 27.54% 40.41% 4.87% 696 25.25% 74.75% 28.21% 41.49% 5.05%
642 27.14% 72.86% 27.55% 40.44% 4.87% 697 25.23% 74.77% 28.22% 41.50% 5.05%
643 27.11% 72.89% 27.57% 40.45% 4.88% 698 25.20% 74.81% 28.24% 41.52% 5.05%
644 27.08% 72.92% 27.58% 40.47% 4.88% 699 25.16% 74.84% 28.24% 41.54% 5.06%
645 27.04% 72.96% 27.59% 40.49% 4.88% 700 25.13% 74.87% 28.25% 41.56% 5.06%
646 27.01% 72.99% 27.60% 40.50% 4.89% 701 25.10% 74.90% 28.27% 41.58% 5.06%
647 26.97% 73.03% 27.61% 40.53% 4.89% 702 25.07% 74.93% 28.28% 41.60% 5.06%
648 26.93% 73.07% 27.62% 40.55% 4.89% 703 25.04% 74.96% 28.29% 41.61% 5.07%
649 26.90% 73.10% 27.63% 40.57% 4.90% 704 25.01% 74.99% 28.30% 41.62% 5.07%
650 26.86% 73.14% 27.65% 40.60% 4.90% 705 24.98% 75.02% 28.30% 41.64% 5.08%
651 26.83% 73.17% 27.66% 40.61% 4.90% 706 24.96% 75.04% 28.31% 41.66% 5.08%
652 26.79% 73.21% 27.67% 40.63% 4.91% 707 24.93% 75.07% 28.32% 41.67% 5.08%
653 26.75% 73.25% 27.68% 40.66% 4.91% 708 24.89% 75.11% 28.33% 41.70% 5.08%
654 26.72% 73.28% 27.70% 40.67% 4.91% 709 24.86% 75.14% 28.34% 41.71% 5.09%
655 26.69% 73.32% 27.71% 40.69% 4.92% 710 24.82% 75.18% 28.35% 41.73% 5.09%
656 26.65% 73.36% 27.72% 40.72% 4.92% 711 24.80% 75.20% 28.36% 41.74% 5.09%
657 26.61% 73.39% 27.73% 40.74% 4.92% 712 24.78% 75.23% 28.37% 41.76% 5.10%
658 26.57% 73.43% 27.75% 40.76% 4.92% 713 24.75% 75.25% 28.38% 41.77% 5.10%
659 26.54% 73.47% 27.76% 40.78% 4.93% 714 24.72% 75.28% 28.39% 41.79% 5.10%
660 26.50% 73.50% 27.78% 40.79% 4.93% 715 24.69% 75.31% 28.40% 41.81% 5.11%
661 26.47% 73.53% 27.79% 40.81% 4.93% 716 24.66% 75.34% 28.41% 41.83% 5.11%
662 26.43% 73.57% 27.80% 40.83% 4.93% 717 24.62% 75.38% 28.42% 41.85% 5.11%
663 26.40% 73.60% 27.81% 40.85% 4.94% 718 24.58% 75.42% 28.43% 41.87% 5.12%
664 26.35% 73.65% 27.83% 40.87% 4.95% 719 24.56% 75.44% 28.44% 41.89% 5.12%
665 26.32% 73.68% 27.84% 40.89% 4.95% 720 24.54% 75.46% 28.45% 41.90% 5.12%
666 26.30% 73.71% 27.85% 40.90% 4.95% 721 24.50% 75.50% 28.46% 41.92% 5.13%
667 26.26% 73.74% 27.86% 40.93% 4.95% 722 24.47% 75.53% 28.47% 41.94% 5.13%
668 26.22% 73.78% 27.87% 40.95% 4.96% 723 24.44% 75.57% 28.48% 41.96% 5.13%
669 26.19% 73.81% 27.88% 40.97% 4.96% 724 24.41% 75.59% 28.48% 41.97% 5.13%
670 26.15% 73.85% 27.90% 40.99% 4.96% 725 24.38% 75.62% 28.49% 41.99% 5.14%
671 26.10% 73.90% 27.91% 41.02% 4.97% 726 24.37% 75.63% 28.50% 42.00% 5.14%
672 26.06% 73.94% 27.93% 41.04% 4.97% 727 24.33% 75.67% 28.51% 42.02% 5.14%
673 26.02% 73.98% 27.94% 41.06% 4.98% 728 24.30% 75.70% 28.52% 42.04% 5.14%
674 25.99% 74.01% 27.95% 41.08% 4.99% 729 24.27% 75.73% 28.54% 42.05% 5.14%
675 25.95% 74.05% 27.96% 41.10% 4.99% 730 24.24% 75.76% 28.55% 42.07% 5.14%
676 25.92% 74.08% 27.97% 41.12% 4.99% 731 24.21% 75.79% 28.56% 42.09% 5.15%
677 25.89% 74.11% 27.99% 41.13% 4.99% 732 24.18% 75.82% 28.57% 42.10% 5.15%
172
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 733 24.15% 75.85% 28.58% 42.12% 5.16% 788 22.66% 77.34% 29.10% 42.94% 5.31%
734 24.13% 75.88% 28.58% 42.14% 5.16% 789 22.63% 77.37% 29.11% 42.95% 5.31%
735 24.10% 75.91% 28.59% 42.16% 5.16% 790 22.61% 77.39% 29.12% 42.96% 5.31%
736 24.07% 75.93% 28.60% 42.17% 5.16% 791 22.57% 77.43% 29.13% 42.98% 5.32%
737 24.04% 75.96% 28.60% 42.19% 5.17% 792 22.54% 77.46% 29.14% 43.00% 5.32%
738 24.01% 75.99% 28.61% 42.21% 5.17% 793 22.51% 77.49% 29.15% 43.01% 5.32%
739 23.97% 76.03% 28.63% 42.24% 5.17% 794 22.49% 77.51% 29.16% 43.03% 5.32%
740 23.93% 76.07% 28.64% 42.26% 5.18% 795 22.46% 77.54% 29.18% 43.04% 5.33%
741 23.90% 76.11% 28.65% 42.28% 5.18% 796 22.43% 77.58% 29.18% 43.06% 5.33%
742 23.87% 76.13% 28.66% 42.29% 5.18% 797 22.41% 77.59% 29.19% 43.07% 5.33%
743 23.84% 76.16% 28.67% 42.31% 5.18% 798 22.38% 77.62% 29.20% 43.09% 5.33%
744 23.82% 76.18% 28.67% 42.33% 5.19% 799 22.35% 77.65% 29.22% 43.10% 5.34%
745 23.79% 76.21% 28.68% 42.34% 5.19% 800 22.32% 77.68% 29.23% 43.11% 5.34%
746 23.76% 76.24% 28.69% 42.36% 5.20% 801 22.30% 77.70% 29.23% 43.12% 5.34%
747 23.74% 76.26% 28.70% 42.36% 5.20% 802 22.27% 77.74% 29.25% 43.15% 5.34%
748 23.71% 76.29% 28.71% 42.38% 5.20% 803 22.24% 77.76% 29.25% 43.16% 5.34%
749 23.67% 76.33% 28.72% 42.40% 5.21% 804 22.22% 77.78% 29.26% 43.18% 5.35%
750 23.64% 76.36% 28.74% 42.42% 5.21% 805 22.20% 77.80% 29.27% 43.18% 5.35%
751 23.61% 76.40% 28.75% 42.44% 5.21% 806 22.18% 77.82% 29.27% 43.19% 5.35%
752 23.58% 76.42% 28.75% 42.45% 5.21% 807 22.16% 77.84% 29.27% 43.21% 5.36%
753 23.55% 76.45% 28.76% 42.47% 5.22% 808 22.13% 77.87% 29.28% 43.22% 5.36%
754 23.53% 76.47% 28.77% 42.48% 5.22% 809 22.11% 77.89% 29.29% 43.24% 5.36%
755 23.50% 76.50% 28.78% 42.49% 5.23% 810 22.09% 77.91% 29.30% 43.25% 5.36%
756 23.49% 76.51% 28.79% 42.50% 5.23% 811 22.06% 77.94% 29.31% 43.26% 5.37%
757 23.46% 76.54% 28.79% 42.52% 5.23% 812 22.03% 77.97% 29.32% 43.28% 5.37%
758 23.43% 76.57% 28.81% 42.54% 5.23% 813 22.02% 77.98% 29.32% 43.29% 5.37%
759 23.41% 76.59% 28.81% 42.55% 5.23% 814 21.99% 78.01% 29.34% 43.30% 5.37%
760 23.38% 76.63% 28.83% 42.56% 5.23% 815 21.96% 78.04% 29.35% 43.31% 5.38%
761 23.34% 76.66% 28.84% 42.58% 5.24% 816 21.93% 78.07% 29.37% 43.32% 5.38%
762 23.31% 76.69% 28.85% 42.60% 5.24% 817 21.91% 78.09% 29.37% 43.34% 5.38%
763 23.28% 76.72% 28.86% 42.61% 5.24% 818 21.88% 78.12% 29.38% 43.36% 5.39%
764 23.26% 76.74% 28.87% 42.63% 5.25% 819 21.86% 78.14% 29.39% 43.37% 5.39%
765 23.24% 76.76% 28.88% 42.63% 5.25% 820 21.84% 78.16% 29.39% 43.38% 5.39%
766 23.21% 76.79% 28.89% 42.65% 5.25% 821 21.82% 78.18% 29.39% 43.39% 5.39%
767 23.18% 76.82% 28.90% 42.66% 5.26% 822 21.79% 78.21% 29.40% 43.41% 5.40%
768 23.16% 76.84% 28.92% 42.67% 5.26% 823 21.77% 78.23% 29.41% 43.42% 5.40%
769 23.13% 76.87% 28.93% 42.68% 5.26% 824 21.75% 78.25% 29.42% 43.43% 5.40%
770 23.10% 76.90% 28.94% 42.69% 5.26% 825 21.72% 78.28% 29.43% 43.45% 5.40%
771 23.08% 76.92% 28.95% 42.70% 5.27% 826 21.70% 78.30% 29.43% 43.46% 5.40%
772 23.05% 76.95% 28.96% 42.72% 5.27% 827 21.68% 78.32% 29.45% 43.47% 5.41%
773 23.03% 76.97% 28.97% 42.73% 5.28% 828 21.64% 78.36% 29.46% 43.49% 5.41%
774 22.99% 77.01% 28.98% 42.75% 5.28% 829 21.62% 78.38% 29.47% 43.50% 5.42%
775 22.97% 77.03% 28.99% 42.76% 5.28% 830 21.59% 78.41% 29.48% 43.52% 5.42%
776 22.94% 77.06% 29.00% 42.78% 5.28% 831 21.56% 78.44% 29.48% 43.54% 5.42%
777 22.92% 77.08% 29.01% 42.79% 5.28% 832 21.53% 78.47% 29.50% 43.55% 5.42%
778 22.90% 77.10% 29.01% 42.81% 5.29% 833 21.51% 78.49% 29.51% 43.56% 5.42%
779 22.86% 77.14% 29.03% 42.82% 5.29% 834 21.49% 78.51% 29.51% 43.57% 5.42%
780 22.84% 77.16% 29.03% 42.84% 5.29% 835 21.47% 78.53% 29.52% 43.59% 5.43%
781 22.82% 77.18% 29.04% 42.85% 5.29% 836 21.45% 78.56% 29.53% 43.60% 5.43%
782 22.79% 77.21% 29.05% 42.86% 5.30% 837 21.42% 78.58% 29.53% 43.61% 5.43%
783 22.77% 77.23% 29.05% 42.88% 5.30% 838 21.39% 78.61% 29.54% 43.63% 5.44%
784 22.76% 77.24% 29.06% 42.89% 5.30% 839 21.36% 78.64% 29.55% 43.65% 5.44%
785 22.73% 77.27% 29.07% 42.90% 5.30% 840 21.34% 78.66% 29.56% 43.66% 5.44%
786 22.71% 77.29% 29.08% 42.91% 5.30% 841 21.32% 78.68% 29.57% 43.67% 5.45%
787 22.68% 77.32% 29.09% 42.93% 5.30% 842 21.30% 78.70% 29.57% 43.68% 5.45%
173
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 843 21.27% 78.73% 29.58% 43.69% 5.45% 898 20.02% 79.98% 30.03% 44.37% 5.58%
844 21.26% 78.75% 29.59% 43.70% 5.45% 899 20.00% 80.00% 30.04% 44.38% 5.58%
845 21.23% 78.77% 29.59% 43.72% 5.46% 900 19.99% 80.01% 30.04% 44.39% 5.58%
846 21.20% 78.80% 29.60% 43.73% 5.46% 901 19.97% 80.03% 30.05% 44.40% 5.59%
847 21.17% 78.83% 29.61% 43.75% 5.46% 902 19.95% 80.05% 30.06% 44.41% 5.59%
848 21.15% 78.85% 29.62% 43.77% 5.46% 903 19.92% 80.08% 30.07% 44.42% 5.59%
849 21.12% 78.88% 29.63% 43.78% 5.47% 904 19.91% 80.09% 30.08% 44.43% 5.59%
850 21.10% 78.90% 29.64% 43.79% 5.47% 905 19.89% 80.12% 30.08% 44.44% 5.60%
851 21.08% 78.92% 29.64% 43.81% 5.47% 906 19.86% 80.14% 30.09% 44.45% 5.60%
852 21.06% 78.94% 29.65% 43.81% 5.47% 907 19.85% 80.15% 30.09% 44.46% 5.60%
853 21.03% 78.97% 29.66% 43.83% 5.48% 908 19.83% 80.18% 30.10% 44.47% 5.60%
854 21.01% 78.99% 29.67% 43.85% 5.48% 909 19.81% 80.19% 30.11% 44.48% 5.61%
855 20.99% 79.01% 29.67% 43.86% 5.48% 910 19.78% 80.22% 30.12% 44.50% 5.61%
856 20.97% 79.03% 29.68% 43.87% 5.48% 911 19.77% 80.23% 30.12% 44.50% 5.61%
857 20.94% 79.06% 29.69% 43.88% 5.49% 912 19.75% 80.25% 30.13% 44.52% 5.61%
858 20.92% 79.08% 29.70% 43.89% 5.49% 913 19.73% 80.27% 30.13% 44.53% 5.61%
859 20.89% 79.11% 29.72% 43.90% 5.49% 914 19.71% 80.29% 30.14% 44.54% 5.61%
860 20.85% 79.15% 29.73% 43.92% 5.49% 915 19.69% 80.31% 30.15% 44.55% 5.61%
861 20.83% 79.17% 29.74% 43.94% 5.50% 916 19.68% 80.33% 30.15% 44.56% 5.61%
862 20.81% 79.19% 29.74% 43.95% 5.50% 917 19.66% 80.34% 30.16% 44.57% 5.62%
863 20.80% 79.20% 29.75% 43.96% 5.50% 918 19.64% 80.36% 30.16% 44.59% 5.62%
864 20.77% 79.23% 29.75% 43.97% 5.51% 919 19.62% 80.38% 30.17% 44.60% 5.62%
865 20.75% 79.25% 29.76% 43.98% 5.51% 920 19.59% 80.41% 30.17% 44.61% 5.63%
866 20.73% 79.27% 29.77% 44.00% 5.51% 921 19.58% 80.42% 30.18% 44.62% 5.63%
867 20.71% 79.29% 29.77% 44.01% 5.51% 922 19.56% 80.44% 30.18% 44.63% 5.63%
868 20.68% 79.32% 29.78% 44.03% 5.51% 923 19.54% 80.47% 30.19% 44.64% 5.63%
869 20.65% 79.35% 29.79% 44.04% 5.52% 924 19.51% 80.49% 30.20% 44.65% 5.63%
870 20.62% 79.38% 29.80% 44.06% 5.52% 925 19.49% 80.51% 30.21% 44.67% 5.64%
871 20.60% 79.40% 29.81% 44.06% 5.52% 926 19.47% 80.53% 30.22% 44.67% 5.64%
872 20.58% 79.42% 29.82% 44.08% 5.53% 927 19.44% 80.56% 30.23% 44.68% 5.64%
873 20.56% 79.44% 29.82% 44.09% 5.53% 928 19.42% 80.58% 30.24% 44.69% 5.64%
874 20.54% 79.46% 29.84% 44.10% 5.53% 929 19.40% 80.60% 30.25% 44.70% 5.64%
875 20.52% 79.48% 29.84% 44.11% 5.53% 930 19.38% 80.63% 30.26% 44.72% 5.65%
876 20.49% 79.51% 29.85% 44.12% 5.54% 931 19.35% 80.65% 30.27% 44.73% 5.65%
877 20.47% 79.53% 29.86% 44.14% 5.54% 932 19.33% 80.67% 30.28% 44.74% 5.65%
878 20.45% 79.55% 29.87% 44.14% 5.54% 933 19.31% 80.69% 30.29% 44.75% 5.65%
879 20.43% 79.58% 29.88% 44.16% 5.54% 934 19.29% 80.71% 30.30% 44.76% 5.66%
880 20.40% 79.60% 29.89% 44.17% 5.55% 935 19.26% 80.74% 30.31% 44.77% 5.66%
881 20.38% 79.62% 29.90% 44.18% 5.55% 936 19.24% 80.76% 30.32% 44.78% 5.66%
882 20.36% 79.64% 29.90% 44.19% 5.55% 937 19.22% 80.78% 30.32% 44.80% 5.66%
883 20.34% 79.66% 29.91% 44.20% 5.55% 938 19.20% 80.80% 30.33% 44.81% 5.66%
884 20.32% 79.69% 29.92% 44.22% 5.55% 939 19.18% 80.82% 30.33% 44.82% 5.67%
885 20.29% 79.71% 29.92% 44.23% 5.56% 940 19.17% 80.83% 30.34% 44.83% 5.67%
886 20.27% 79.73% 29.93% 44.24% 5.56% 941 19.15% 80.85% 30.34% 44.84% 5.67%
887 20.25% 79.75% 29.94% 44.25% 5.56% 942 19.14% 80.86% 30.35% 44.85% 5.67%
888 20.22% 79.78% 29.95% 44.26% 5.56% 943 19.12% 80.88% 30.35% 44.86% 5.67%
889 20.20% 79.81% 29.96% 44.28% 5.57% 944 19.11% 80.89% 30.36% 44.87% 5.67%
890 20.17% 79.83% 29.98% 44.29% 5.57% 945 19.09% 80.91% 30.37% 44.88% 5.67%
891 20.16% 79.84% 29.98% 44.29% 5.57% 946 19.07% 80.93% 30.37% 44.88% 5.67%
892 20.14% 79.87% 29.99% 44.30% 5.57% 947 19.05% 80.95% 30.38% 44.89% 5.68%
893 20.12% 79.88% 30.00% 44.31% 5.57% 948 19.03% 80.97% 30.39% 44.90% 5.68%
894 20.10% 79.90% 30.00% 44.33% 5.57% 949 19.01% 80.99% 30.40% 44.92% 5.68%
895 20.09% 79.91% 30.01% 44.33% 5.57% 950 19.00% 81.01% 30.40% 44.92% 5.68%
896 20.07% 79.94% 30.02% 44.34% 5.58% 951 18.98% 81.02% 30.41% 44.93% 5.68%
897 20.04% 79.96% 30.03% 44.35% 5.58% 952 18.96% 81.04% 30.42% 44.94% 5.68%
174
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 953 18.94% 81.06% 30.43% 44.95% 5.69% 1008 17.94% 82.06% 30.78% 45.50% 5.79%
954 18.92% 81.08% 30.43% 44.96% 5.69% 1009 17.92% 82.08% 30.79% 45.50% 5.79%
955 18.89% 81.11% 30.44% 44.98% 5.69% 1010 17.90% 82.10% 30.80% 45.51% 5.79%
956 18.87% 81.13% 30.45% 44.99% 5.69% 1011 17.89% 82.11% 30.80% 45.52% 5.80%
957 18.85% 81.15% 30.46% 45.01% 5.69% 1012 17.86% 82.14% 30.81% 45.54% 5.80%
958 18.83% 81.17% 30.46% 45.02% 5.69% 1013 17.84% 82.16% 30.81% 45.55% 5.80%
959 18.81% 81.19% 30.47% 45.03% 5.69% 1014 17.83% 82.17% 30.82% 45.55% 5.80%
960 18.79% 81.21% 30.48% 45.04% 5.69% 1015 17.81% 82.19% 30.82% 45.56% 5.80%
961 18.78% 81.22% 30.48% 45.04% 5.70% 1016 17.80% 82.20% 30.83% 45.57% 5.80%
962 18.76% 81.24% 30.49% 45.05% 5.70% 1017 17.78% 82.22% 30.84% 45.58% 5.80%
963 18.75% 81.26% 30.49% 45.06% 5.70% 1018 17.76% 82.24% 30.85% 45.58% 5.81%
964 18.73% 81.27% 30.50% 45.07% 5.71% 1019 17.75% 82.25% 30.86% 45.59% 5.81%
965 18.71% 81.29% 30.51% 45.07% 5.71% 1020 17.74% 82.26% 30.86% 45.60% 5.81%
966 18.69% 81.31% 30.51% 45.08% 5.71% 1021 17.73% 82.28% 30.86% 45.60% 5.81%
967 18.67% 81.33% 30.52% 45.09% 5.72% 1022 17.72% 82.28% 30.86% 45.61% 5.81%
968 18.66% 81.35% 30.53% 45.10% 5.72% 1023 17.70% 82.30% 30.87% 45.62% 5.81%
969 18.64% 81.36% 30.53% 45.11% 5.72% 1024 17.68% 82.32% 30.88% 45.63% 5.81%
970 18.63% 81.37% 30.53% 45.12% 5.72% 1025 17.67% 82.33% 30.88% 45.63% 5.82%
971 18.61% 81.39% 30.53% 45.13% 5.72% 1026 17.65% 82.35% 30.89% 45.64% 5.82%
972 18.60% 81.40% 30.54% 45.14% 5.72% 1027 17.63% 82.37% 30.90% 45.65% 5.82%
973 18.59% 81.41% 30.54% 45.15% 5.72% 1028 17.62% 82.38% 30.91% 45.66% 5.82%
974 18.57% 81.43% 30.55% 45.16% 5.73% 1029 17.60% 82.40% 30.91% 45.67% 5.82%
975 18.55% 81.45% 30.56% 45.16% 5.73% 1030 17.59% 82.41% 30.92% 45.67% 5.82%
976 18.53% 81.47% 30.57% 45.17% 5.73% 1031 17.58% 82.43% 30.92% 45.68% 5.83%
977 18.51% 81.49% 30.57% 45.18% 5.73% 1032 17.56% 82.44% 30.93% 45.69% 5.83%
978 18.50% 81.50% 30.58% 45.19% 5.73% 1033 17.54% 82.46% 30.93% 45.70% 5.83%
979 18.48% 81.52% 30.58% 45.21% 5.74% 1034 17.53% 82.47% 30.94% 45.70% 5.83%
980 18.46% 81.54% 30.59% 45.22% 5.74% 1035 17.51% 82.50% 30.95% 45.71% 5.83%
981 18.44% 81.57% 30.60% 45.22% 5.74% 1036 17.49% 82.51% 30.95% 45.73% 5.83%
982 18.42% 81.58% 30.61% 45.23% 5.74% 1037 17.47% 82.53% 30.96% 45.74% 5.83%
983 18.40% 81.60% 30.61% 45.24% 5.75% 1038 17.45% 82.55% 30.97% 45.75% 5.84%
984 18.38% 81.62% 30.62% 45.25% 5.75% 1039 17.43% 82.57% 30.97% 45.76% 5.84%
985 18.37% 81.63% 30.63% 45.26% 5.75% 1040 17.42% 82.58% 30.98% 45.77% 5.84%
986 18.34% 81.66% 30.64% 45.28% 5.75% 1041 17.40% 82.60% 30.98% 45.78% 5.84%
987 18.32% 81.68% 30.64% 45.29% 5.75% 1042 17.38% 82.62% 30.99% 45.78% 5.84%
988 18.31% 81.69% 30.65% 45.30% 5.75% 1043 17.36% 82.65% 31.00% 45.80% 5.84%
989 18.29% 81.71% 30.65% 45.31% 5.75% 1044 17.34% 82.66% 31.00% 45.81% 5.84%
990 18.27% 81.73% 30.65% 45.32% 5.76% 1045 17.33% 82.67% 31.01% 45.82% 5.84%
991 18.25% 81.75% 30.67% 45.33% 5.76% 1046 17.32% 82.69% 31.01% 45.83% 5.85%
992 18.23% 81.77% 30.68% 45.34% 5.76% 1047 17.29% 82.71% 31.02% 45.84% 5.85%
993 18.21% 81.79% 30.69% 45.35% 5.76% 1048 17.28% 82.73% 31.02% 45.85% 5.85%
994 18.19% 81.81% 30.69% 45.36% 5.77% 1049 17.26% 82.74% 31.03% 45.86% 5.85%
995 18.17% 81.83% 30.70% 45.37% 5.77% 1050 17.24% 82.76% 31.04% 45.87% 5.86%
996 18.15% 81.85% 30.71% 45.38% 5.77% 1051 17.22% 82.78% 31.04% 45.88% 5.86%
997 18.13% 81.87% 30.71% 45.39% 5.77% 1052 17.21% 82.79% 31.05% 45.89% 5.86%
998 18.11% 81.89% 30.72% 45.40% 5.77% 1053 17.19% 82.81% 31.05% 45.89% 5.86%
999 18.09% 81.91% 30.73% 45.41% 5.78% 1054 17.18% 82.82% 31.05% 45.91% 5.87%
1000 18.07% 81.93% 30.73% 45.42% 5.78% 1055 17.17% 82.83% 31.06% 45.91% 5.87%
1001 18.06% 81.94% 30.74% 45.42% 5.78% 1056 17.15% 82.85% 31.07% 45.92% 5.87%
1002 18.04% 81.96% 30.74% 45.43% 5.78% 1057 17.13% 82.87% 31.07% 45.93% 5.87%
1003 18.03% 81.97% 30.75% 45.44% 5.78% 1058 17.12% 82.88% 31.08% 45.93% 5.87%
1004 18.02% 81.98% 30.75% 45.45% 5.78% 1059 17.11% 82.89% 31.08% 45.94% 5.87%
1005 18.00% 82.00% 30.76% 45.46% 5.78% 1060 17.09% 82.91% 31.09% 45.95% 5.87%
1006 17.98% 82.02% 30.77% 45.47% 5.79% 1061 17.08% 82.93% 31.10% 45.95% 5.88%
1007 17.96% 82.04% 30.77% 45.48% 5.79% 1062 17.06% 82.94% 31.10% 45.96% 5.88%
175
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 1063 17.06% 82.94% 31.11% 45.96% 5.88% 1118 16.27% 83.73% 31.41% 46.38% 5.95%
1064 17.05% 82.95% 31.11% 45.97% 5.88% 1119 16.26% 83.74% 31.41% 46.38% 5.95%
1065 17.03% 82.97% 31.11% 45.97% 5.89% 1120 16.25% 83.75% 31.42% 46.39% 5.95%
1066 17.02% 82.98% 31.12% 45.98% 5.89% 1121 16.24% 83.76% 31.42% 46.39% 5.95%
1067 17.00% 83.00% 31.13% 45.99% 5.89% 1122 16.23% 83.77% 31.42% 46.40% 5.95%
1068 16.99% 83.01% 31.13% 46.00% 5.89% 1123 16.20% 83.80% 31.43% 46.41% 5.95%
1069 16.98% 83.03% 31.14% 46.00% 5.89% 1124 16.18% 83.82% 31.44% 46.43% 5.96%
1070 16.96% 83.04% 31.15% 46.01% 5.89% 1125 16.17% 83.83% 31.44% 46.43% 5.96%
1071 16.95% 83.05% 31.15% 46.01% 5.89% 1126 16.16% 83.84% 31.44% 46.44% 5.96%
1072 16.94% 83.06% 31.15% 46.02% 5.89% 1127 16.14% 83.86% 31.45% 46.45% 5.96%
1073 16.92% 83.08% 31.17% 46.02% 5.89% 1128 16.13% 83.87% 31.46% 46.46% 5.96%
1074 16.91% 83.09% 31.17% 46.03% 5.90% 1129 16.12% 83.88% 31.46% 46.46% 5.96%
1075 16.90% 83.10% 31.17% 46.04% 5.90% 1130 16.10% 83.90% 31.47% 46.47% 5.96%
1076 16.89% 83.11% 31.17% 46.04% 5.90% 1131 16.09% 83.91% 31.47% 46.47% 5.96%
1077 16.87% 83.13% 31.18% 46.05% 5.90% 1132 16.07% 83.93% 31.48% 46.48% 5.97%
1078 16.86% 83.14% 31.18% 46.06% 5.90% 1133 16.06% 83.94% 31.48% 46.49% 5.97%
1079 16.84% 83.16% 31.19% 46.07% 5.90% 1134 16.05% 83.95% 31.49% 46.50% 5.97%
1080 16.82% 83.18% 31.20% 46.08% 5.90% 1135 16.04% 83.96% 31.49% 46.50% 5.97%
1081 16.81% 83.19% 31.20% 46.09% 5.90% 1136 16.02% 83.98% 31.50% 46.51% 5.97%
1082 16.80% 83.20% 31.21% 46.10% 5.90% 1137 16.01% 83.99% 31.51% 46.51% 5.97%
1083 16.78% 83.22% 31.22% 46.10% 5.90% 1138 16.00% 84.00% 31.51% 46.52% 5.97%
1084 16.77% 83.23% 31.22% 46.11% 5.90% 1139 15.99% 84.01% 31.52% 46.52% 5.97%
1085 16.76% 83.24% 31.22% 46.12% 5.90% 1140 15.97% 84.03% 31.52% 46.53% 5.98%
1086 16.74% 83.26% 31.23% 46.12% 5.90% 1141 15.96% 84.04% 31.53% 46.54% 5.98%
1087 16.73% 83.27% 31.23% 46.13% 5.91% 1142 15.94% 84.06% 31.54% 46.54% 5.98%
1088 16.72% 83.28% 31.24% 46.14% 5.91% 1143 15.93% 84.07% 31.54% 46.54% 5.98%
1089 16.70% 83.30% 31.24% 46.14% 5.91% 1144 15.92% 84.08% 31.55% 46.55% 5.98%
1090 16.69% 83.31% 31.25% 46.15% 5.91% 1145 15.90% 84.10% 31.56% 46.56% 5.98%
1091 16.68% 83.32% 31.25% 46.15% 5.91% 1146 15.89% 84.11% 31.56% 46.57% 5.98%
1092 16.67% 83.33% 31.25% 46.16% 5.91% 1147 15.88% 84.12% 31.56% 46.57% 5.98%
1093 16.66% 83.34% 31.26% 46.17% 5.92% 1148 15.87% 84.13% 31.57% 46.58% 5.99%
1094 16.64% 83.36% 31.27% 46.18% 5.92% 1149 15.86% 84.14% 31.57% 46.58% 5.99%
1095 16.63% 83.38% 31.27% 46.19% 5.92% 1150 15.85% 84.16% 31.58% 46.59% 5.99%
1096 16.61% 83.39% 31.28% 46.20% 5.92% 1151 15.83% 84.17% 31.58% 46.60% 5.99%
1097 16.60% 83.40% 31.28% 46.20% 5.92% 1152 15.82% 84.18% 31.59% 46.60% 5.99%
1098 16.58% 83.42% 31.29% 46.22% 5.92% 1153 15.80% 84.20% 31.59% 46.62% 5.99%
1099 16.56% 83.44% 31.29% 46.23% 5.92% 1154 15.79% 84.21% 31.59% 46.62% 5.99%
1100 16.54% 83.46% 31.30% 46.24% 5.92% 1155 15.78% 84.22% 31.60% 46.63% 5.99%
1101 16.53% 83.47% 31.30% 46.25% 5.92% 1156 15.76% 84.24% 31.61% 46.64% 5.99%
1102 16.51% 83.49% 31.31% 46.26% 5.92% 1157 15.74% 84.26% 31.61% 46.65% 6.00%
1103 16.49% 83.51% 31.31% 46.27% 5.92% 1158 15.73% 84.27% 31.62% 46.66% 6.00%
1104 16.48% 83.52% 31.32% 46.28% 5.92% 1159 15.71% 84.29% 31.63% 46.67% 6.00%
1105 16.47% 83.54% 31.33% 46.28% 5.93% 1160 15.69% 84.31% 31.63% 46.68% 6.00%
1106 16.44% 83.56% 31.33% 46.30% 5.93% 1161 15.68% 84.32% 31.64% 46.69% 6.00%
1107 16.43% 83.57% 31.33% 46.30% 5.93% 1162 15.66% 84.34% 31.65% 46.69% 6.00%
1108 16.42% 83.58% 31.34% 46.31% 5.93% 1163 15.65% 84.35% 31.65% 46.69% 6.00%
1109 16.40% 83.60% 31.35% 46.32% 5.93% 1164 15.65% 84.36% 31.65% 46.70% 6.00%
1110 16.39% 83.61% 31.35% 46.32% 5.94% 1165 15.63% 84.38% 31.66% 46.71% 6.01%
1111 16.37% 83.63% 31.36% 46.34% 5.94% 1166 15.61% 84.39% 31.66% 46.72% 6.01%
1112 16.36% 83.64% 31.36% 46.34% 5.94% 1167 15.60% 84.40% 31.67% 46.73% 6.01%
1113 16.35% 83.65% 31.37% 46.35% 5.94% 1168 15.58% 84.42% 31.67% 46.74% 6.01%
1114 16.33% 83.67% 31.37% 46.35% 5.94% 1169 15.57% 84.43% 31.68% 46.74% 6.01%
1115 16.31% 83.69% 31.39% 46.36% 5.95% 1170 15.56% 84.44% 31.68% 46.74% 6.01%
1116 16.29% 83.71% 31.40% 46.37% 5.95% 1171 15.55% 84.45% 31.69% 46.75% 6.01%
1117 16.28% 83.72% 31.40% 46.37% 5.95% 1172 15.54% 84.46% 31.69% 46.75% 6.01%
176
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 1173 15.53% 84.47% 31.70% 46.76% 6.02%
1174 15.52% 84.48% 31.70% 46.76% 6.02%
1175 15.51% 84.49% 31.71% 46.77% 6.02%
1176 15.50% 84.50% 31.71% 46.77% 6.02%
1177 15.49% 84.52% 31.71% 46.78% 6.02%
1178 15.48% 84.52% 31.72% 46.79% 6.02%
1179 15.46% 84.54% 31.72% 46.80% 6.03%
1180 15.45% 84.55% 31.72% 46.80% 6.03%
1181 15.44% 84.57% 31.73% 46.81% 6.03%
1182 15.43% 84.58% 31.73% 46.81% 6.03%
1183 15.41% 84.59% 31.73% 46.82% 6.03%
1184 15.40% 84.60% 31.74% 46.83% 6.03%
1185 15.39% 84.61% 31.74% 46.83% 6.04%
1186 15.38% 84.62% 31.75% 46.84% 6.04%
1187 15.37% 84.64% 31.75% 46.84% 6.04%
1188 15.35% 84.65% 31.76% 46.85% 6.04%
1189 15.35% 84.66% 31.76% 46.85% 6.04%
1190 15.34% 84.66% 31.77% 46.86% 6.04%
1191 15.33% 84.67% 31.77% 46.86% 6.04%
1192 15.31% 84.69% 31.78% 46.87% 6.05%
1193 15.30% 84.70% 31.78% 46.87% 6.05%
1194 15.29% 84.71% 31.78% 46.88% 6.05%
1195 15.29% 84.71% 31.79% 46.88% 6.05%
1196 15.27% 84.73% 31.79% 46.89% 6.05%
1197 15.25% 84.75% 31.80% 46.90% 6.05%
1198 15.24% 84.76% 31.80% 46.91% 6.05%
1199 15.23% 84.77% 31.81% 46.91% 6.05%
1200 15.22% 84.78% 31.81% 46.92% 6.05%
177
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA
-306 97.91% 2.09% 0.63% 1.45% 0.00%
-305 97.89% 2.11% 0.63% 1.46% 0.00%
Table B4. LOCA Probability History for ASP-03 -304 97.88% 2.12% 0.64% 1.47% 0.00%
for Days After TOD -303 97.86% 2.14% 0.64% 1.49% 0.00%
-302 97.85% 2.15% 0.64% 1.49% 0.00%
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA -301 97.83% 2.17% 0.65% 1.51% 0.00%
-365 98.61% 1.39% 0.44% 0.94% 0.00% -300 97.81% 2.19% 0.65% 1.52% 0.00%
-364 98.59% 1.41% 0.44% 0.96% 0.00% -299 97.80% 2.20% 0.65% 1.54% 0.00%
-363 98.59% 1.41% 0.45% 0.96% 0.00% -298 97.79% 2.21% 0.66% 1.55% 0.00%
-362 98.57% 1.43% 0.46% 0.97% 0.00% -297 97.77% 2.23% 0.66% 1.56% 0.00%
-361 98.56% 1.44% 0.46% 0.98% 0.00% -296 97.75% 2.25% 0.67% 1.57% 0.00%
-360 98.55% 1.45% 0.46% 0.98% 0.00% -295 97.74% 2.26% 0.67% 1.58% 0.00%
-359 98.54% 1.46% 0.47% 0.99% 0.00% -294 97.72% 2.28% 0.67% 1.60% 0.00%
-358 98.53% 1.47% 0.47% 1.00% 0.00% -293 97.71% 2.29% 0.67% 1.60% 0.00%
-357 98.52% 1.48% 0.47% 1.01% 0.00% -292 97.69% 2.31% 0.68% 1.62% 0.00%
-356 98.51% 1.49% 0.47% 1.02% 0.00% -291 97.68% 2.33% 0.68% 1.63% 0.00%
-355 98.50% 1.50% 0.47% 1.02% 0.00% -290 97.66% 2.34% 0.69% 1.65% 0.00%
-354 98.49% 1.51% 0.47% 1.03% 0.00% -289 97.64% 2.36% 0.69% 1.66% 0.00%
-353 98.48% 1.52% 0.47% 1.04% 0.00% -288 97.62% 2.38% 0.70% 1.67% 0.00%
-352 98.48% 1.52% 0.48% 1.04% 0.00% -287 97.59% 2.41% 0.71% 1.69% 0.00%
-351 98.47% 1.53% 0.48% 1.04% 0.00% -286 97.57% 2.43% 0.71% 1.71% 0.00%
-350 98.46% 1.54% 0.48% 1.05% 0.00% -285 97.56% 2.44% 0.71% 1.71% 0.00%
-349 98.44% 1.56% 0.49% 1.06% 0.00% -284 97.54% 2.46% 0.72% 1.73% 0.00%
-348 98.43% 1.57% 0.49% 1.07% 0.00% -283 97.52% 2.48% 0.72% 1.75% 0.00%
-347 98.42% 1.58% 0.49% 1.08% 0.00% -282 97.50% 2.51% 0.73% 1.77% 0.00%
-346 98.41% 1.59% 0.50% 1.09% 0.00% -281 97.47% 2.53% 0.73% 1.78% 0.00%
-345 98.39% 1.61% 0.50% 1.10% 0.00% -280 97.46% 2.54% 0.74% 1.79% 0.00%
-344 98.38% 1.62% 0.50% 1.11% 0.00% -279 97.44% 2.56% 0.74% 1.80% 0.00%
-343 98.38% 1.63% 0.50% 1.11% 0.00% -278 97.43% 2.57% 0.74% 1.82% 0.00%
-342 98.36% 1.64% 0.51% 1.12% 0.00% -277 97.40% 2.60% 0.75% 1.84% 0.00%
-341 98.35% 1.65% 0.51% 1.13% 0.00% -276 97.38% 2.62% 0.75% 1.85% 0.00%
-340 98.34% 1.66% 0.52% 1.13% 0.00% -275 97.37% 2.63% 0.75% 1.86% 0.00%
-339 98.33% 1.67% 0.52% 1.14% 0.00% -274 97.35% 2.65% 0.76% 1.88% 0.00%
-338 98.32% 1.69% 0.52% 1.15% 0.00% -273 97.33% 2.67% 0.76% 1.89% 0.00%
-337 98.30% 1.70% 0.52% 1.17% 0.00% -272 97.32% 2.68% 0.76% 1.90% 0.00%
-336 98.29% 1.71% 0.52% 1.18% 0.00% -271 97.30% 2.70% 0.77% 1.92% 0.00%
-335 98.28% 1.72% 0.53% 1.18% 0.00% -270 97.28% 2.72% 0.77% 1.94% 0.00%
-334 98.27% 1.74% 0.53% 1.19% 0.00% -269 97.26% 2.74% 0.77% 1.95% 0.00%
-333 98.25% 1.75% 0.53% 1.21% 0.00% -268 97.24% 2.76% 0.77% 1.97% 0.00%
-332 98.24% 1.76% 0.54% 1.21% 0.00% -267 97.22% 2.78% 0.78% 1.98% 0.00%
-331 98.23% 1.77% 0.54% 1.22% 0.00% -266 97.20% 2.80% 0.78% 2.00% 0.00%
-330 98.21% 1.79% 0.55% 1.23% 0.00% -265 97.19% 2.81% 0.79% 2.01% 0.00%
-329 98.21% 1.79% 0.55% 1.24% 0.00% -264 97.18% 2.83% 0.80% 2.01% 0.00%
-328 98.20% 1.80% 0.55% 1.24% 0.00% -263 97.15% 2.85% 0.80% 2.03% 0.00%
-327 98.18% 1.82% 0.55% 1.26% 0.00% -262 97.13% 2.87% 0.81% 2.04% 0.00%
-326 98.17% 1.83% 0.55% 1.26% 0.00% -261 97.11% 2.89% 0.82% 2.06% 0.00%
-325 98.16% 1.84% 0.56% 1.27% 0.00% -260 97.09% 2.91% 0.82% 2.07% 0.00%
-324 98.15% 1.86% 0.56% 1.28% 0.00% -259 97.07% 2.93% 0.83% 2.08% 0.00%
-323 98.13% 1.87% 0.57% 1.29% 0.00% -258 97.06% 2.94% 0.83% 2.10% 0.00%
-322 98.11% 1.89% 0.57% 1.31% 0.00% -257 97.04% 2.96% 0.84% 2.11% 0.00%
-321 98.11% 1.89% 0.57% 1.31% 0.00% -256 97.01% 2.99% 0.84% 2.13% 0.00%
-320 98.08% 1.92% 0.58% 1.33% 0.00% -255 97.00% 3.00% 0.84% 2.14% 0.00%
-319 98.07% 1.93% 0.58% 1.33% 0.00% -254 96.98% 3.03% 0.85% 2.16% 0.00%
-318 98.06% 1.94% 0.59% 1.34% 0.00% -253 96.95% 3.05% 0.86% 2.17% 0.00%
-317 98.05% 1.95% 0.59% 1.35% 0.00% -252 96.93% 3.07% 0.87% 2.19% 0.00%
-316 98.04% 1.96% 0.59% 1.36% 0.00% -251 96.91% 3.10% 0.87% 2.21% 0.00%
-315 98.03% 1.97% 0.60% 1.36% 0.00% -250 96.88% 3.12% 0.88% 2.23% 0.00%
-314 98.02% 1.98% 0.60% 1.37% 0.00% -249 96.86% 3.14% 0.88% 2.24% 0.00%
-313 98.00% 2.00% 0.60% 1.38% 0.00% -248 96.83% 3.17% 0.88% 2.27% 0.00%
-312 97.99% 2.01% 0.61% 1.39% 0.00% -247 96.80% 3.20% 0.89% 2.29% 0.00%
-311 97.98% 2.02% 0.61% 1.39% 0.00% -246 96.78% 3.22% 0.90% 2.31% 0.00%
-310 97.97% 2.03% 0.61% 1.40% 0.00% -245 96.76% 3.24% 0.90% 2.33% 0.00%
-309 97.96% 2.05% 0.62% 1.42% 0.00% -244 96.73% 3.27% 0.91% 2.34% 0.00%
-308 97.93% 2.07% 0.63% 1.43% 0.00% -243 96.70% 3.30% 0.91% 2.37% 0.00%
-307 97.92% 2.08% 0.63% 1.44% 0.00% -242 96.67% 3.33% 0.92% 2.39% 0.00%
178
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA
-241 96.65% 3.35% 0.92% 2.41% 0.00% -176 94.44% 5.56% 1.33% 4.16% 0.05%
-240 96.63% 3.37% 0.92% 2.43% 0.00% -175 94.39% 5.61% 1.33% 4.20% 0.05%
-239 96.62% 3.38% 0.93% 2.43% 0.00% -174 94.34% 5.66% 1.34% 4.25% 0.05%
-238 96.58% 3.42% 0.94% 2.46% 0.00% -173 94.30% 5.70% 1.35% 4.28% 0.05%
-237 96.55% 3.45% 0.94% 2.48% 0.00% -172 94.24% 5.76% 1.35% 4.33% 0.06%
-236 96.53% 3.47% 0.95% 2.51% 0.00% -171 94.21% 5.79% 1.36% 4.36% 0.06%
-235 96.50% 3.51% 0.95% 2.53% 0.00% -170 94.16% 5.84% 1.36% 4.40% 0.06%
-234 96.47% 3.53% 0.96% 2.55% 0.00% -169 94.13% 5.88% 1.36% 4.43% 0.06%
-233 96.44% 3.57% 0.97% 2.57% 0.00% -168 94.08% 5.92% 1.37% 4.46% 0.06%
-232 96.40% 3.60% 0.98% 2.60% 0.01% -167 94.03% 5.97% 1.38% 4.50% 0.06%
-231 96.38% 3.62% 0.98% 2.61% 0.01% -166 93.99% 6.01% 1.38% 4.54% 0.07%
-230 96.35% 3.65% 0.99% 2.64% 0.01% -165 93.95% 6.05% 1.39% 4.57% 0.07%
-229 96.32% 3.69% 0.99% 2.67% 0.01% -164 93.90% 6.10% 1.40% 4.62% 0.07%
-228 96.28% 3.72% 1.00% 2.69% 0.01% -163 93.86% 6.14% 1.40% 4.65% 0.07%
-227 96.26% 3.74% 1.01% 2.71% 0.01% -162 93.83% 6.17% 1.41% 4.67% 0.07%
-226 96.23% 3.77% 1.02% 2.73% 0.01% -161 93.77% 6.23% 1.41% 4.72% 0.07%
-225 96.20% 3.80% 1.02% 2.75% 0.01% -160 93.73% 6.27% 1.42% 4.76% 0.07%
-224 96.17% 3.83% 1.03% 2.78% 0.01% -159 93.69% 6.31% 1.43% 4.79% 0.08%
-223 96.15% 3.86% 1.03% 2.80% 0.01% -158 93.65% 6.35% 1.44% 4.82% 0.08%
-222 96.12% 3.88% 1.04% 2.82% 0.01% -157 93.60% 6.40% 1.45% 4.85% 0.08%
-221 96.09% 3.91% 1.04% 2.84% 0.01% -156 93.55% 6.45% 1.45% 4.89% 0.08%
-220 96.06% 3.94% 1.05% 2.87% 0.01% -155 93.50% 6.50% 1.47% 4.93% 0.09%
-219 96.03% 3.97% 1.06% 2.89% 0.01% -154 93.47% 6.53% 1.47% 4.95% 0.09%
-218 96.00% 4.00% 1.06% 2.91% 0.01% -153 93.43% 6.57% 1.48% 4.99% 0.09%
-217 95.97% 4.03% 1.07% 2.93% 0.01% -152 93.36% 6.64% 1.49% 5.04% 0.10%
-216 95.94% 4.06% 1.07% 2.96% 0.01% -151 93.30% 6.70% 1.50% 5.08% 0.10%
-215 95.91% 4.09% 1.08% 2.99% 0.01% -150 93.27% 6.74% 1.50% 5.11% 0.11%
-214 95.88% 4.12% 1.08% 3.00% 0.01% -149 93.22% 6.79% 1.51% 5.15% 0.11%
-213 95.85% 4.16% 1.09% 3.04% 0.01% -148 93.18% 6.82% 1.51% 5.18% 0.11%
-212 95.82% 4.18% 1.09% 3.05% 0.01% -147 93.13% 6.87% 1.52% 5.21% 0.11%
-211 95.80% 4.20% 1.10% 3.07% 0.01% -146 93.09% 6.92% 1.53% 5.25% 0.12%
-210 95.77% 4.23% 1.10% 3.10% 0.01% -145 93.04% 6.96% 1.53% 5.29% 0.12%
-209 95.73% 4.27% 1.11% 3.14% 0.01% -144 92.98% 7.02% 1.54% 5.33% 0.12%
-208 95.69% 4.31% 1.11% 3.16% 0.01% -143 92.93% 7.08% 1.56% 5.37% 0.13%
-207 95.66% 4.34% 1.12% 3.19% 0.01% -142 92.86% 7.14% 1.57% 5.42% 0.13%
-206 95.62% 4.38% 1.13% 3.22% 0.02% -141 92.83% 7.17% 1.57% 5.45% 0.14%
-205 95.60% 4.40% 1.13% 3.23% 0.02% -140 92.78% 7.22% 1.57% 5.49% 0.14%
-204 95.57% 4.44% 1.14% 3.26% 0.02% -139 92.71% 7.29% 1.58% 5.54% 0.15%
-203 95.53% 4.47% 1.15% 3.29% 0.02% -138 92.65% 7.35% 1.60% 5.58% 0.15%
-202 95.49% 4.51% 1.15% 3.32% 0.02% -137 92.60% 7.40% 1.60% 5.63% 0.15%
-201 95.45% 4.55% 1.16% 3.36% 0.02% -136 92.53% 7.47% 1.62% 5.67% 0.16%
-200 95.41% 4.59% 1.17% 3.38% 0.02% -135 92.48% 7.52% 1.63% 5.71% 0.17%
-199 95.38% 4.62% 1.18% 3.41% 0.02% -134 92.42% 7.58% 1.63% 5.76% 0.17%
-198 95.34% 4.67% 1.18% 3.44% 0.02% -133 92.36% 7.65% 1.64% 5.81% 0.18%
-197 95.30% 4.70% 1.19% 3.47% 0.02% -132 92.30% 7.70% 1.65% 5.85% 0.18%
-196 95.26% 4.74% 1.20% 3.50% 0.02% -131 92.24% 7.76% 1.66% 5.90% 0.19%
-195 95.23% 4.78% 1.20% 3.53% 0.02% -130 92.20% 7.80% 1.66% 5.94% 0.19%
-194 95.19% 4.81% 1.21% 3.56% 0.03% -129 92.14% 7.86% 1.67% 5.98% 0.19%
-193 95.14% 4.86% 1.22% 3.59% 0.03% -128 92.07% 7.93% 1.68% 6.03% 0.20%
-192 95.11% 4.89% 1.23% 3.62% 0.03% -127 92.01% 7.99% 1.69% 6.08% 0.20%
-191 95.07% 4.93% 1.23% 3.65% 0.03% -126 91.95% 8.06% 1.70% 6.13% 0.21%
-190 95.03% 4.98% 1.24% 3.68% 0.03% -125 91.90% 8.10% 1.71% 6.17% 0.21%
-189 94.98% 5.02% 1.25% 3.72% 0.03% -124 91.83% 8.18% 1.72% 6.22% 0.22%
-188 94.94% 5.06% 1.26% 3.75% 0.03% -123 91.78% 8.22% 1.72% 6.26% 0.22%
-187 94.90% 5.10% 1.27% 3.78% 0.04% -122 91.73% 8.27% 1.73% 6.30% 0.22%
-186 94.86% 5.14% 1.27% 3.81% 0.04% -121 91.67% 8.33% 1.73% 6.34% 0.23%
-185 94.83% 5.17% 1.28% 3.84% 0.04% -120 91.61% 8.39% 1.74% 6.39% 0.24%
-184 94.80% 5.20% 1.28% 3.86% 0.04% -119 91.53% 8.47% 1.75% 6.45% 0.25%
-183 94.75% 5.25% 1.29% 3.91% 0.04% -118 91.45% 8.55% 1.76% 6.51% 0.26%
-182 94.71% 5.29% 1.29% 3.94% 0.04% -117 91.38% 8.62% 1.76% 6.57% 0.27%
-181 94.65% 5.35% 1.30% 3.99% 0.04% -116 91.29% 8.71% 1.77% 6.64% 0.28%
-180 94.61% 5.39% 1.30% 4.03% 0.04% -115 91.21% 8.79% 1.78% 6.70% 0.29%
-179 94.57% 5.43% 1.31% 4.06% 0.04% -114 91.14% 8.86% 1.79% 6.75% 0.30%
-178 94.53% 5.47% 1.31% 4.09% 0.04% -113 91.07% 8.93% 1.80% 6.80% 0.31%
-177 94.48% 5.52% 1.32% 4.13% 0.05% -112 90.99% 9.01% 1.82% 6.85% 0.32%
179
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA
-111 90.92% 9.08% 1.82% 6.91% 0.33% -46 85.38% 14.62% 2.44% 10.92% 1.25%
-110 90.85% 9.15% 1.83% 6.97% 0.33% -45 85.27% 14.73% 2.45% 10.99% 1.28%
-109 90.78% 9.22% 1.84% 7.02% 0.34% -44 85.17% 14.83% 2.46% 11.06% 1.30%
-108 90.71% 9.29% 1.84% 7.07% 0.35% -43 85.05% 14.95% 2.47% 11.14% 1.32%
-107 90.64% 9.36% 1.85% 7.13% 0.36% -42 84.92% 15.08% 2.49% 11.21% 1.36%
-106 90.58% 9.42% 1.86% 7.17% 0.37% -41 84.84% 15.16% 2.50% 11.27% 1.38%
-105 90.51% 9.49% 1.87% 7.22% 0.38% -40 84.76% 15.25% 2.50% 11.33% 1.40%
-104 90.44% 9.56% 1.88% 7.27% 0.39% -39 84.65% 15.35% 2.51% 11.39% 1.42%
-103 90.37% 9.63% 1.89% 7.32% 0.39% -38 84.54% 15.46% 2.52% 11.46% 1.46%
-102 90.30% 9.70% 1.90% 7.39% 0.40% -37 84.44% 15.56% 2.54% 11.52% 1.48%
-101 90.21% 9.79% 1.91% 7.46% 0.41% -36 84.33% 15.67% 2.55% 11.59% 1.51%
-100 90.13% 9.87% 1.92% 7.52% 0.41% -35 84.22% 15.78% 2.56% 11.66% 1.54%
-99 90.07% 9.93% 1.93% 7.57% 0.42% -34 84.11% 15.89% 2.57% 11.74% 1.57%
-98 89.99% 10.01% 1.94% 7.62% 0.44% -33 84.01% 15.99% 2.58% 11.81% 1.59%
-97 89.88% 10.12% 1.94% 7.70% 0.45% -32 83.92% 16.08% 2.60% 11.86% 1.61%
-96 89.82% 10.19% 1.95% 7.76% 0.46% -31 83.81% 16.19% 2.61% 11.92% 1.65%
-95 89.74% 10.26% 1.96% 7.81% 0.47% -30 83.70% 16.30% 2.62% 11.98% 1.68%
-94 89.67% 10.33% 1.97% 7.87% 0.48% -29 83.61% 16.40% 2.62% 12.05% 1.70%
-93 89.59% 10.41% 1.97% 7.93% 0.49% -28 83.50% 16.50% 2.63% 12.13% 1.72%
-92 89.51% 10.49% 1.99% 7.98% 0.50% -27 83.39% 16.61% 2.64% 12.20% 1.75%
-91 89.43% 10.57% 2.01% 8.03% 0.51% -26 83.29% 16.71% 2.65% 12.28% 1.77%
-90 89.34% 10.66% 2.02% 8.09% 0.53% -25 83.18% 16.82% 2.65% 12.34% 1.80%
-89 89.26% 10.74% 2.03% 8.15% 0.54% -24 83.09% 16.91% 2.66% 12.41% 1.82%
-88 89.19% 10.82% 2.04% 8.20% 0.55% -23 82.97% 17.03% 2.67% 12.50% 1.84%
-87 89.11% 10.89% 2.05% 8.26% 0.56% -22 82.85% 17.15% 2.68% 12.58% 1.86%
-86 89.03% 10.97% 2.06% 8.31% 0.57% -21 82.74% 17.26% 2.69% 12.65% 1.90%
-85 88.97% 11.04% 2.07% 8.37% 0.58% -20 82.62% 17.38% 2.70% 12.73% 1.93%
-84 88.88% 11.12% 2.08% 8.43% 0.60% -19 82.51% 17.50% 2.71% 12.79% 1.97%
-83 88.81% 11.20% 2.09% 8.48% 0.61% -18 82.40% 17.60% 2.72% 12.86% 2.00%
-82 88.73% 11.27% 2.09% 8.54% 0.62% -17 82.30% 17.70% 2.73% 12.92% 2.03%
-81 88.66% 11.34% 2.10% 8.59% 0.64% -16 82.18% 17.82% 2.74% 13.01% 2.05%
-80 88.58% 11.42% 2.11% 8.64% 0.64% -15 82.06% 17.94% 2.75% 13.09% 2.08%
-79 88.50% 11.50% 2.13% 8.70% 0.66% -14 81.95% 18.05% 2.76% 13.16% 2.11%
-78 88.42% 11.58% 2.14% 8.75% 0.68% -13 81.84% 18.16% 2.77% 13.23% 2.14%
-77 88.34% 11.66% 2.15% 8.80% 0.69% -12 81.71% 18.29% 2.79% 13.31% 2.17%
-76 88.26% 11.74% 2.15% 8.87% 0.69% -11 81.57% 18.43% 2.80% 13.40% 2.22%
-75 88.18% 11.82% 2.16% 8.93% 0.71% -10 81.44% 18.56% 2.82% 13.47% 2.26%
-74 88.09% 11.91% 2.17% 9.00% 0.72% -9 81.33% 18.67% 2.83% 13.54% 2.29%
-73 88.00% 12.00% 2.18% 9.07% 0.73% -8 81.19% 18.81% 2.83% 13.63% 2.33%
-72 87.90% 12.10% 2.19% 9.14% 0.75% -7 81.07% 18.93% 2.85% 13.70% 2.36%
-71 87.81% 12.19% 2.20% 9.21% 0.76% -6 80.93% 19.07% 2.86% 13.78% 2.41%
-70 87.73% 12.27% 2.21% 9.27% 0.78% -5 80.80% 19.20% 2.87% 13.86% 2.45%
-69 87.64% 12.36% 2.22% 9.33% 0.79% -4 80.68% 19.32% 2.88% 13.93% 2.49%
-68 87.57% 12.43% 2.23% 9.37% 0.81% -3 80.56% 19.44% 2.90% 13.99% 2.54%
-67 87.47% 12.53% 2.24% 9.44% 0.82% -2 80.42% 19.58% 2.91% 14.08% 2.58%
-66 87.38% 12.62% 2.25% 9.51% 0.84% -1 80.28% 19.73% 2.92% 14.16% 2.62%
-65 87.28% 12.72% 2.26% 9.58% 0.86% 0 79.94% 20.07% 2.93% 14.23% 2.89%
-64 87.18% 12.82% 2.27% 9.64% 0.88% 1 79.78% 20.22% 2.94% 14.33% 2.94%
-63 87.08% 12.92% 2.28% 9.71% 0.91% 2 79.61% 20.39% 2.95% 14.40% 3.02%
-62 86.98% 13.02% 2.29% 9.79% 0.93% 3 79.46% 20.55% 2.96% 14.48% 3.08%
-61 86.88% 13.12% 2.30% 9.85% 0.95% 4 79.31% 20.69% 2.97% 14.56% 3.14%
-60 86.78% 13.22% 2.31% 9.93% 0.97% 5 79.18% 20.82% 2.98% 14.64% 3.18%
-59 86.69% 13.31% 2.32% 9.98% 0.99% 6 79.05% 20.95% 2.99% 14.71% 3.23%
-58 86.59% 13.41% 2.32% 10.06% 1.01% 7 78.92% 21.08% 3.00% 14.79% 3.27%
-57 86.50% 13.50% 2.33% 10.12% 1.03% 8 78.78% 21.22% 3.01% 14.87% 3.32%
-56 86.39% 13.61% 2.34% 10.20% 1.05% 9 78.66% 21.34% 3.02% 14.94% 3.36%
-55 86.29% 13.71% 2.35% 10.27% 1.07% 10 78.53% 21.47% 3.03% 15.02% 3.40%
-54 86.19% 13.81% 2.36% 10.34% 1.09% 11 78.38% 21.62% 3.04% 15.12% 3.45%
-53 86.07% 13.93% 2.38% 10.42% 1.11% 12 78.25% 21.76% 3.04% 15.20% 3.50%
-52 85.99% 14.01% 2.38% 10.50% 1.12% 13 78.11% 21.89% 3.05% 15.28% 3.54%
-51 85.88% 14.12% 2.39% 10.57% 1.14% 14 77.98% 22.02% 3.07% 15.36% 3.57%
-50 85.79% 14.21% 2.40% 10.63% 1.17% 15 77.83% 22.17% 3.08% 15.46% 3.61%
-49 85.69% 14.32% 2.40% 10.70% 1.19% 16 77.69% 22.31% 3.09% 15.53% 3.66%
-48 85.60% 14.40% 2.41% 10.77% 1.21% 17 77.56% 22.44% 3.11% 15.60% 3.72%
-47 85.49% 14.51% 2.42% 10.84% 1.23% 18 77.41% 22.59% 3.12% 15.68% 3.77%
180
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 19 77.24% 22.76% 3.13% 15.78% 3.83% 84 67.89% 32.11% 3.77% 21.30% 7.02%
20 77.09% 22.91% 3.14% 15.87% 3.88% 85 67.75% 32.26% 3.78% 21.39% 7.06%
21 76.94% 23.07% 3.16% 15.96% 3.93% 86 67.62% 32.38% 3.79% 21.47% 7.10%
22 76.79% 23.21% 3.17% 16.04% 3.98% 87 67.47% 32.53% 3.80% 21.56% 7.15%
23 76.64% 23.36% 3.18% 16.12% 4.05% 88 67.33% 32.68% 3.81% 21.65% 7.20%
24 76.50% 23.50% 3.18% 16.20% 4.09% 89 67.17% 32.83% 3.82% 21.73% 7.26%
25 76.34% 23.66% 3.20% 16.29% 4.16% 90 67.03% 32.97% 3.83% 21.82% 7.31%
26 76.21% 23.79% 3.21% 16.35% 4.21% 91 66.90% 33.11% 3.83% 21.90% 7.35%
27 76.05% 23.95% 3.22% 16.45% 4.26% 92 66.75% 33.26% 3.84% 22.00% 7.39%
28 75.89% 24.11% 3.23% 16.55% 4.31% 93 66.61% 33.39% 3.85% 22.08% 7.45%
29 75.76% 24.24% 3.24% 16.61% 4.37% 94 66.47% 33.53% 3.86% 22.16% 7.49%
30 75.63% 24.37% 3.25% 16.69% 4.41% 95 66.31% 33.69% 3.87% 22.25% 7.54%
31 75.49% 24.51% 3.26% 16.77% 4.46% 96 66.18% 33.83% 3.88% 22.33% 7.59%
32 75.35% 24.65% 3.28% 16.85% 4.50% 97 66.03% 33.97% 3.89% 22.42% 7.65%
33 75.21% 24.80% 3.29% 16.94% 4.55% 98 65.89% 34.11% 3.89% 22.51% 7.69%
34 75.08% 24.92% 3.30% 17.01% 4.59% 99 65.75% 34.25% 3.90% 22.59% 7.74%
35 74.95% 25.05% 3.31% 17.08% 4.64% 100 65.60% 34.40% 3.91% 22.67% 7.79%
36 74.79% 25.21% 3.32% 17.17% 4.70% 101 65.45% 34.55% 3.92% 22.77% 7.84%
37 74.63% 25.37% 3.33% 17.26% 4.76% 102 65.32% 34.68% 3.92% 22.86% 7.88%
38 74.51% 25.50% 3.34% 17.33% 4.81% 103 65.17% 34.83% 3.93% 22.94% 7.94%
39 74.36% 25.64% 3.35% 17.41% 4.86% 104 65.02% 34.99% 3.95% 23.04% 7.98%
40 74.21% 25.79% 3.36% 17.50% 4.91% 105 64.88% 35.12% 3.96% 23.12% 8.02%
41 74.07% 25.94% 3.37% 17.59% 4.96% 106 64.71% 35.29% 3.97% 23.21% 8.09%
42 73.90% 26.10% 3.37% 17.68% 5.02% 107 64.58% 35.42% 3.98% 23.30% 8.13%
43 73.76% 26.24% 3.38% 17.77% 5.06% 108 64.44% 35.56% 3.99% 23.38% 8.18%
44 73.62% 26.38% 3.39% 17.86% 5.11% 109 64.27% 35.73% 3.99% 23.49% 8.23%
45 73.48% 26.52% 3.40% 17.93% 5.16% 110 64.11% 35.89% 4.00% 23.58% 8.29%
46 73.34% 26.66% 3.41% 18.02% 5.21% 111 63.97% 36.03% 4.01% 23.67% 8.34%
47 73.21% 26.79% 3.43% 18.09% 5.26% 112 63.80% 36.20% 4.02% 23.76% 8.40%
48 73.07% 26.93% 3.44% 18.15% 5.32% 113 63.63% 36.37% 4.03% 23.85% 8.47%
49 72.91% 27.09% 3.45% 18.24% 5.38% 114 63.45% 36.55% 4.04% 23.95% 8.54%
50 72.78% 27.23% 3.46% 18.32% 5.43% 115 63.30% 36.70% 4.05% 24.04% 8.60%
51 72.63% 27.37% 3.47% 18.40% 5.48% 116 63.17% 36.84% 4.05% 24.12% 8.65%
52 72.49% 27.51% 3.48% 18.50% 5.52% 117 63.00% 37.01% 4.06% 24.21% 8.72%
53 72.36% 27.64% 3.49% 18.57% 5.56% 118 62.83% 37.17% 4.08% 24.30% 8.77%
54 72.22% 27.78% 3.50% 18.66% 5.60% 119 62.68% 37.32% 4.08% 24.38% 8.84%
55 72.09% 27.91% 3.51% 18.74% 5.64% 120 62.50% 37.50% 4.09% 24.47% 8.92%
56 71.96% 28.04% 3.52% 18.81% 5.69% 121 62.36% 37.64% 4.10% 24.55% 8.97%
57 71.82% 28.19% 3.53% 18.91% 5.73% 122 62.22% 37.78% 4.11% 24.63% 9.02%
58 71.69% 28.31% 3.54% 18.98% 5.77% 123 62.09% 37.91% 4.12% 24.71% 9.07%
59 71.54% 28.46% 3.55% 19.08% 5.82% 124 61.93% 38.07% 4.13% 24.79% 9.13%
60 71.41% 28.59% 3.55% 19.16% 5.86% 125 61.79% 38.21% 4.14% 24.87% 9.18%
61 71.25% 28.75% 3.56% 19.26% 5.91% 126 61.65% 38.35% 4.15% 24.95% 9.24%
62 71.12% 28.88% 3.57% 19.34% 5.95% 127 61.51% 38.49% 4.16% 25.02% 9.29%
63 70.98% 29.02% 3.58% 19.43% 5.99% 128 61.36% 38.64% 4.17% 25.11% 9.34%
64 70.84% 29.17% 3.59% 19.51% 6.05% 129 61.23% 38.77% 4.17% 25.20% 9.39%
65 70.70% 29.31% 3.59% 19.60% 6.09% 130 61.05% 38.95% 4.18% 25.29% 9.45%
66 70.55% 29.46% 3.60% 19.69% 6.14% 131 60.92% 39.08% 4.19% 25.36% 9.51%
67 70.41% 29.59% 3.61% 19.77% 6.19% 132 60.79% 39.21% 4.19% 25.43% 9.57%
68 70.28% 29.72% 3.62% 19.84% 6.24% 133 60.64% 39.36% 4.20% 25.51% 9.63%
69 70.14% 29.86% 3.63% 19.92% 6.29% 134 60.49% 39.51% 4.21% 25.60% 9.69%
70 69.99% 30.01% 3.64% 20.01% 6.33% 135 60.35% 39.65% 4.21% 25.69% 9.73%
71 69.83% 30.17% 3.65% 20.11% 6.39% 136 60.21% 39.79% 4.22% 25.77% 9.78%
72 69.67% 30.33% 3.66% 20.20% 6.46% 137 60.07% 39.93% 4.23% 25.86% 9.83%
73 69.52% 30.48% 3.67% 20.30% 6.50% 138 59.92% 40.08% 4.24% 25.94% 9.88%
74 69.36% 30.64% 3.68% 20.41% 6.53% 139 59.78% 40.22% 4.25% 26.02% 9.93%
75 69.23% 30.77% 3.69% 20.48% 6.59% 140 59.64% 40.36% 4.26% 26.10% 9.99%
76 69.08% 30.92% 3.70% 20.56% 6.64% 141 59.49% 40.51% 4.26% 26.18% 10.05%
77 68.94% 31.06% 3.70% 20.65% 6.70% 142 59.35% 40.65% 4.28% 26.26% 10.10%
78 68.80% 31.20% 3.71% 20.73% 6.74% 143 59.19% 40.82% 4.29% 26.34% 10.17%
79 68.65% 31.36% 3.72% 20.83% 6.78% 144 59.03% 40.97% 4.30% 26.43% 10.23%
80 68.49% 31.51% 3.74% 20.92% 6.83% 145 58.88% 41.12% 4.31% 26.50% 10.29%
81 68.34% 31.66% 3.74% 21.02% 6.89% 146 58.72% 41.28% 4.32% 26.59% 10.35%
82 68.18% 31.82% 3.76% 21.11% 6.94% 147 58.59% 41.42% 4.33% 26.66% 10.41%
83 68.03% 31.97% 3.77% 21.20% 6.98% 148 58.43% 41.57% 4.34% 26.72% 10.48%
181
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 149 58.30% 41.70% 4.35% 26.80% 10.53% 214 50.05% 49.95% 4.78% 31.42% 13.74%
150 58.17% 41.83% 4.36% 26.87% 10.58% 215 49.94% 50.06% 4.78% 31.48% 13.78%
151 58.05% 41.95% 4.36% 26.94% 10.63% 216 49.80% 50.20% 4.79% 31.56% 13.83%
152 57.90% 42.10% 4.37% 27.02% 10.70% 217 49.68% 50.33% 4.80% 31.62% 13.89%
153 57.76% 42.24% 4.37% 27.09% 10.76% 218 49.58% 50.42% 4.81% 31.67% 13.93%
154 57.60% 42.40% 4.38% 27.18% 10.82% 219 49.46% 50.54% 4.81% 31.73% 13.97%
155 57.45% 42.55% 4.39% 27.26% 10.89% 220 49.34% 50.66% 4.82% 31.80% 14.02%
156 57.33% 42.68% 4.39% 27.32% 10.94% 221 49.23% 50.77% 4.82% 31.86% 14.06%
157 57.17% 42.83% 4.40% 27.41% 10.99% 222 49.13% 50.88% 4.83% 31.92% 14.11%
158 57.02% 42.98% 4.41% 27.51% 11.05% 223 49.02% 50.98% 4.84% 31.98% 14.15%
159 56.90% 43.10% 4.42% 27.57% 11.10% 224 48.90% 51.10% 4.85% 32.04% 14.20%
160 56.77% 43.23% 4.42% 27.64% 11.15% 225 48.80% 51.21% 4.86% 32.09% 14.24%
161 56.66% 43.34% 4.43% 27.71% 11.19% 226 48.68% 51.32% 4.86% 32.15% 14.28%
162 56.53% 43.47% 4.44% 27.78% 11.23% 227 48.58% 51.42% 4.87% 32.21% 14.33%
163 56.41% 43.60% 4.44% 27.86% 11.28% 228 48.46% 51.54% 4.87% 32.27% 14.38%
164 56.27% 43.73% 4.45% 27.93% 11.33% 229 48.37% 51.63% 4.88% 32.33% 14.41%
165 56.14% 43.86% 4.46% 28.00% 11.38% 230 48.25% 51.75% 4.88% 32.40% 14.45%
166 56.02% 43.98% 4.46% 28.07% 11.43% 231 48.15% 51.85% 4.89% 32.45% 14.49%
167 55.88% 44.12% 4.47% 28.15% 11.48% 232 48.05% 51.95% 4.90% 32.51% 14.52%
168 55.76% 44.24% 4.48% 28.21% 11.53% 233 47.93% 52.07% 4.90% 32.59% 14.57%
169 55.63% 44.37% 4.49% 28.30% 11.57% 234 47.81% 52.19% 4.91% 32.65% 14.61%
170 55.52% 44.48% 4.49% 28.36% 11.61% 235 47.72% 52.28% 4.91% 32.70% 14.65%
171 55.38% 44.62% 4.50% 28.43% 11.67% 236 47.61% 52.39% 4.91% 32.76% 14.69%
172 55.26% 44.74% 4.50% 28.50% 11.72% 237 47.49% 52.51% 4.92% 32.83% 14.74%
173 55.12% 44.88% 4.52% 28.58% 11.77% 238 47.39% 52.61% 4.93% 32.89% 14.78%
174 54.99% 45.01% 4.52% 28.64% 11.83% 239 47.30% 52.71% 4.94% 32.94% 14.81%
175 54.83% 45.17% 4.53% 28.74% 11.88% 240 47.16% 52.84% 4.94% 33.01% 14.86%
176 54.71% 45.30% 4.54% 28.81% 11.93% 241 47.05% 52.95% 4.95% 33.08% 14.89%
177 54.58% 45.42% 4.55% 28.88% 11.97% 242 46.96% 53.04% 4.96% 33.13% 14.93%
178 54.47% 45.54% 4.56% 28.95% 12.01% 243 46.86% 53.14% 4.96% 33.20% 14.96%
179 54.34% 45.66% 4.56% 29.01% 12.07% 244 46.74% 53.26% 4.97% 33.26% 15.01%
180 54.22% 45.78% 4.56% 29.09% 12.11% 245 46.65% 53.35% 4.97% 33.32% 15.04%
181 54.08% 45.92% 4.57% 29.16% 12.17% 246 46.55% 53.45% 4.98% 33.39% 15.07%
182 53.95% 46.05% 4.58% 29.24% 12.21% 247 46.41% 53.59% 4.98% 33.46% 15.13%
183 53.81% 46.19% 4.59% 29.31% 12.27% 248 46.30% 53.70% 4.99% 33.53% 15.16%
184 53.66% 46.34% 4.59% 29.39% 12.33% 249 46.20% 53.80% 4.99% 33.58% 15.20%
185 53.56% 46.45% 4.60% 29.46% 12.37% 250 46.09% 53.92% 5.00% 33.66% 15.24%
186 53.43% 46.57% 4.60% 29.52% 12.42% 251 45.96% 54.04% 5.00% 33.74% 15.28%
187 53.31% 46.69% 4.62% 29.58% 12.48% 252 45.85% 54.15% 5.00% 33.80% 15.32%
188 53.19% 46.81% 4.62% 29.65% 12.52% 253 45.77% 54.23% 5.01% 33.84% 15.36%
189 53.06% 46.94% 4.63% 29.72% 12.57% 254 45.67% 54.33% 5.02% 33.90% 15.39%
190 52.93% 47.07% 4.64% 29.79% 12.62% 255 45.56% 54.44% 5.02% 33.95% 15.45%
191 52.81% 47.19% 4.65% 29.85% 12.67% 256 45.45% 54.55% 5.03% 34.00% 15.50%
192 52.69% 47.31% 4.66% 29.92% 12.72% 257 45.35% 54.66% 5.03% 34.07% 15.54%
193 52.58% 47.42% 4.66% 29.98% 12.76% 258 45.23% 54.77% 5.04% 34.12% 15.59%
194 52.47% 47.53% 4.67% 30.05% 12.80% 259 45.13% 54.87% 5.04% 34.16% 15.65%
195 52.33% 47.68% 4.68% 30.13% 12.85% 260 45.03% 54.97% 5.05% 34.21% 15.69%
196 52.20% 47.80% 4.68% 30.21% 12.90% 261 44.91% 55.09% 5.05% 34.28% 15.73%
197 52.05% 47.95% 4.68% 30.28% 12.96% 262 44.81% 55.19% 5.06% 34.35% 15.77%
198 51.94% 48.06% 4.69% 30.34% 13.00% 263 44.71% 55.29% 5.06% 34.41% 15.80%
199 51.82% 48.18% 4.70% 30.41% 13.05% 264 44.62% 55.38% 5.07% 34.46% 15.83%
200 51.70% 48.30% 4.71% 30.48% 13.10% 265 44.52% 55.48% 5.07% 34.51% 15.88%
201 51.58% 48.42% 4.71% 30.54% 13.15% 266 44.41% 55.59% 5.07% 34.57% 15.93%
202 51.46% 48.54% 4.71% 30.61% 13.20% 267 44.31% 55.70% 5.08% 34.63% 15.97%
203 51.37% 48.63% 4.72% 30.66% 13.24% 268 44.21% 55.79% 5.08% 34.67% 16.02%
204 51.24% 48.76% 4.72% 30.72% 13.29% 269 44.11% 55.89% 5.09% 34.73% 16.06%
205 51.14% 48.86% 4.73% 30.78% 13.33% 270 44.01% 55.99% 5.09% 34.78% 16.10%
206 51.00% 49.00% 4.73% 30.86% 13.39% 271 43.91% 56.09% 5.10% 34.84% 16.14%
207 50.88% 49.12% 4.74% 30.93% 13.43% 272 43.83% 56.17% 5.10% 34.88% 16.17%
208 50.76% 49.24% 4.75% 31.00% 13.47% 273 43.75% 56.25% 5.11% 34.92% 16.21%
209 50.63% 49.37% 4.76% 31.08% 13.51% 274 43.64% 56.36% 5.11% 34.98% 16.25%
210 50.51% 49.49% 4.76% 31.15% 13.56% 275 43.54% 56.46% 5.12% 35.04% 16.29%
211 50.38% 49.62% 4.76% 31.22% 13.62% 276 43.43% 56.57% 5.12% 35.11% 16.32%
212 50.26% 49.74% 4.77% 31.29% 13.66% 277 43.33% 56.67% 5.13% 35.16% 16.37%
213 50.15% 49.85% 4.77% 31.35% 13.71% 278 43.24% 56.77% 5.13% 35.21% 16.40%
182
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 279 43.13% 56.87% 5.14% 35.27% 16.44% 344 37.44% 62.56% 5.35% 38.51% 18.69%
280 43.05% 56.96% 5.14% 35.32% 16.47% 345 37.34% 62.66% 5.35% 38.57% 18.72%
281 42.94% 57.06% 5.14% 35.39% 16.51% 346 37.25% 62.75% 5.36% 38.62% 18.75%
282 42.85% 57.16% 5.15% 35.44% 16.55% 347 37.19% 62.82% 5.36% 38.66% 18.77%
283 42.76% 57.24% 5.15% 35.48% 16.58% 348 37.11% 62.89% 5.36% 38.70% 18.81%
284 42.68% 57.33% 5.15% 35.53% 16.62% 349 37.04% 62.97% 5.36% 38.75% 18.83%
285 42.58% 57.42% 5.16% 35.59% 16.66% 350 36.94% 63.06% 5.36% 38.80% 18.87%
286 42.48% 57.52% 5.16% 35.65% 16.69% 351 36.86% 63.14% 5.37% 38.86% 18.90%
287 42.37% 57.63% 5.17% 35.71% 16.73% 352 36.78% 63.22% 5.37% 38.90% 18.93%
288 42.25% 57.75% 5.17% 35.77% 16.78% 353 36.72% 63.28% 5.37% 38.94% 18.95%
289 42.13% 57.87% 5.18% 35.84% 16.82% 354 36.63% 63.37% 5.37% 38.98% 18.99%
290 42.04% 57.96% 5.18% 35.90% 16.85% 355 36.54% 63.46% 5.38% 39.03% 19.04%
291 41.96% 58.04% 5.19% 35.95% 16.89% 356 36.46% 63.54% 5.38% 39.08% 19.07%
292 41.86% 58.14% 5.19% 36.01% 16.92% 357 36.40% 63.60% 5.38% 39.12% 19.09%
293 41.77% 58.23% 5.20% 36.06% 16.96% 358 36.33% 63.68% 5.38% 39.16% 19.12%
294 41.68% 58.32% 5.20% 36.10% 16.99% 359 36.25% 63.75% 5.38% 39.20% 19.15%
295 41.59% 58.41% 5.20% 36.16% 17.03% 360 36.17% 63.83% 5.39% 39.24% 19.18%
296 41.51% 58.49% 5.21% 36.21% 17.05% 361 36.10% 63.91% 5.39% 39.28% 19.22%
297 41.43% 58.57% 5.21% 36.26% 17.08% 362 36.02% 63.98% 5.40% 39.32% 19.25%
298 41.34% 58.66% 5.21% 36.31% 17.12% 363 35.96% 64.04% 5.40% 39.36% 19.27%
299 41.25% 58.75% 5.22% 36.36% 17.16% 364 35.88% 64.13% 5.40% 39.41% 19.29%
300 41.15% 58.85% 5.22% 36.42% 17.19% 365 35.81% 64.19% 5.40% 39.44% 19.32%
301 41.07% 58.93% 5.23% 36.46% 17.23% 366 35.74% 64.26% 5.41% 39.48% 19.36%
302 40.98% 59.02% 5.23% 36.50% 17.27% 367 35.68% 64.32% 5.41% 39.51% 19.38%
303 40.87% 59.13% 5.24% 36.57% 17.31% 368 35.61% 64.39% 5.41% 39.55% 19.41%
304 40.78% 59.22% 5.24% 36.62% 17.34% 369 35.54% 64.46% 5.41% 39.59% 19.43%
305 40.70% 59.30% 5.25% 36.68% 17.36% 370 35.46% 64.54% 5.42% 39.65% 19.45%
306 40.62% 59.39% 5.25% 36.72% 17.39% 371 35.40% 64.60% 5.42% 39.69% 19.47%
307 40.52% 59.48% 5.25% 36.78% 17.42% 372 35.33% 64.67% 5.42% 39.73% 19.50%
308 40.43% 59.57% 5.26% 36.84% 17.46% 373 35.25% 64.75% 5.43% 39.78% 19.53%
309 40.35% 59.65% 5.26% 36.88% 17.50% 374 35.17% 64.83% 5.43% 39.81% 19.56%
310 40.24% 59.76% 5.26% 36.94% 17.54% 375 35.09% 64.91% 5.44% 39.85% 19.60%
311 40.16% 59.84% 5.26% 36.98% 17.57% 376 35.04% 64.96% 5.44% 39.89% 19.62%
312 40.09% 59.91% 5.27% 37.02% 17.60% 377 34.97% 65.03% 5.44% 39.93% 19.65%
313 40.00% 60.00% 5.27% 37.07% 17.64% 378 34.89% 65.11% 5.44% 39.97% 19.68%
314 39.92% 60.08% 5.27% 37.12% 17.67% 379 34.83% 65.18% 5.44% 40.00% 19.71%
315 39.84% 60.17% 5.27% 37.17% 17.70% 380 34.76% 65.24% 5.44% 40.04% 19.74%
316 39.74% 60.26% 5.27% 37.22% 17.75% 381 34.69% 65.31% 5.45% 40.09% 19.76%
317 39.66% 60.34% 5.28% 37.27% 17.78% 382 34.62% 65.39% 5.45% 40.13% 19.79%
318 39.57% 60.43% 5.28% 37.32% 17.82% 383 34.56% 65.45% 5.45% 40.16% 19.81%
319 39.49% 60.51% 5.28% 37.36% 17.85% 384 34.49% 65.51% 5.45% 40.20% 19.84%
320 39.40% 60.60% 5.29% 37.40% 17.89% 385 34.41% 65.59% 5.45% 40.25% 19.87%
321 39.33% 60.67% 5.29% 37.44% 17.92% 386 34.36% 65.64% 5.46% 40.27% 19.89%
322 39.25% 60.75% 5.29% 37.49% 17.95% 387 34.29% 65.71% 5.46% 40.31% 19.92%
323 39.16% 60.84% 5.29% 37.54% 17.98% 388 34.21% 65.79% 5.46% 40.35% 19.96%
324 39.09% 60.91% 5.29% 37.58% 18.02% 389 34.14% 65.87% 5.46% 40.40% 19.98%
325 39.00% 61.00% 5.30% 37.63% 18.05% 390 34.06% 65.94% 5.46% 40.44% 20.02%
326 38.91% 61.09% 5.30% 37.69% 18.08% 391 33.99% 66.01% 5.47% 40.48% 20.05%
327 38.82% 61.19% 5.30% 37.74% 18.13% 392 33.91% 66.09% 5.47% 40.53% 20.07%
328 38.73% 61.27% 5.31% 37.78% 18.16% 393 33.84% 66.16% 5.47% 40.58% 20.10%
329 38.63% 61.37% 5.31% 37.84% 18.20% 394 33.77% 66.23% 5.47% 40.62% 20.12%
330 38.54% 61.46% 5.31% 37.89% 18.24% 395 33.71% 66.29% 5.47% 40.65% 20.15%
331 38.45% 61.55% 5.31% 37.93% 18.28% 396 33.65% 66.35% 5.47% 40.69% 20.17%
332 38.37% 61.63% 5.32% 37.98% 18.31% 397 33.59% 66.41% 5.47% 40.73% 20.20%
333 38.29% 61.71% 5.32% 38.02% 18.35% 398 33.52% 66.48% 5.47% 40.77% 20.22%
334 38.22% 61.78% 5.32% 38.06% 18.37% 399 33.46% 66.54% 5.47% 40.80% 20.25%
335 38.14% 61.86% 5.32% 38.11% 18.40% 400 33.40% 66.60% 5.48% 40.84% 20.27%
336 38.06% 61.94% 5.33% 38.17% 18.43% 401 33.34% 66.66% 5.48% 40.87% 20.29%
337 37.98% 62.02% 5.33% 38.20% 18.47% 402 33.27% 66.73% 5.48% 40.91% 20.32%
338 37.91% 62.09% 5.33% 38.25% 18.49% 403 33.19% 66.81% 5.49% 40.96% 20.35%
339 37.82% 62.18% 5.34% 38.29% 18.53% 404 33.12% 66.88% 5.49% 41.00% 20.37%
340 37.73% 62.27% 5.34% 38.35% 18.56% 405 33.05% 66.95% 5.49% 41.04% 20.40%
341 37.65% 62.35% 5.34% 38.39% 18.59% 406 32.99% 67.01% 5.49% 41.07% 20.43%
342 37.58% 62.42% 5.34% 38.43% 18.63% 407 32.94% 67.06% 5.50% 41.10% 20.44%
343 37.51% 62.49% 5.34% 38.47% 18.66% 408 32.89% 67.12% 5.50% 41.13% 20.47%
183
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 409 32.82% 67.18% 5.50% 41.17% 20.49% 474 28.96% 71.04% 5.61% 43.43% 21.99%
410 32.77% 67.24% 5.50% 41.21% 20.51% 475 28.90% 71.10% 5.61% 43.46% 22.01%
411 32.70% 67.30% 5.50% 41.24% 20.54% 476 28.86% 71.15% 5.61% 43.49% 22.03%
412 32.64% 67.36% 5.50% 41.28% 20.56% 477 28.80% 71.20% 5.61% 43.51% 22.06%
413 32.57% 67.43% 5.51% 41.32% 20.58% 478 28.74% 71.26% 5.61% 43.54% 22.09%
414 32.51% 67.49% 5.51% 41.36% 20.60% 479 28.69% 71.32% 5.61% 43.57% 22.11%
415 32.44% 67.56% 5.51% 41.40% 20.63% 480 28.63% 71.37% 5.62% 43.61% 22.13%
416 32.38% 67.62% 5.51% 41.44% 20.65% 481 28.59% 71.42% 5.62% 43.63% 22.15%
417 32.30% 67.70% 5.52% 41.47% 20.69% 482 28.53% 71.48% 5.62% 43.66% 22.18%
418 32.23% 67.77% 5.52% 41.51% 20.72% 483 28.48% 71.53% 5.62% 43.69% 22.20%
419 32.17% 67.83% 5.52% 41.54% 20.74% 484 28.42% 71.58% 5.62% 43.72% 22.22%
420 32.11% 67.89% 5.52% 41.57% 20.77% 485 28.37% 71.63% 5.62% 43.76% 22.24%
421 32.06% 67.94% 5.52% 41.61% 20.79% 486 28.32% 71.68% 5.62% 43.78% 22.26%
422 31.99% 68.01% 5.53% 41.64% 20.82% 487 28.27% 71.73% 5.62% 43.82% 22.28%
423 31.93% 68.07% 5.53% 41.68% 20.84% 488 28.22% 71.78% 5.62% 43.84% 22.30%
424 31.87% 68.13% 5.53% 41.71% 20.87% 489 28.17% 71.83% 5.62% 43.87% 22.32%
425 31.81% 68.19% 5.53% 41.75% 20.89% 490 28.12% 71.89% 5.62% 43.90% 22.34%
426 31.75% 68.25% 5.53% 41.78% 20.92% 491 28.06% 71.94% 5.62% 43.94% 22.36%
427 31.69% 68.31% 5.53% 41.82% 20.94% 492 28.01% 71.99% 5.62% 43.96% 22.38%
428 31.62% 68.38% 5.53% 41.86% 20.96% 493 27.96% 72.04% 5.63% 43.99% 22.40%
429 31.57% 68.43% 5.54% 41.89% 20.98% 494 27.90% 72.10% 5.63% 44.03% 22.43%
430 31.51% 68.49% 5.54% 41.92% 21.01% 495 27.85% 72.15% 5.63% 44.05% 22.45%
431 31.46% 68.54% 5.54% 41.95% 21.03% 496 27.81% 72.19% 5.63% 44.08% 22.47%
432 31.40% 68.60% 5.54% 42.00% 21.05% 497 27.76% 72.24% 5.63% 44.10% 22.49%
433 31.33% 68.67% 5.54% 42.03% 21.08% 498 27.70% 72.30% 5.63% 44.13% 22.52%
434 31.28% 68.72% 5.54% 42.06% 21.10% 499 27.64% 72.36% 5.64% 44.16% 22.55%
435 31.23% 68.77% 5.54% 42.09% 21.12% 500 27.59% 72.41% 5.64% 44.19% 22.56%
436 31.16% 68.84% 5.55% 42.13% 21.14% 501 27.53% 72.47% 5.64% 44.23% 22.58%
437 31.11% 68.89% 5.55% 42.16% 21.17% 502 27.48% 72.53% 5.64% 44.26% 22.60%
438 31.05% 68.95% 5.55% 42.19% 21.19% 503 27.41% 72.59% 5.64% 44.29% 22.64%
439 31.00% 69.00% 5.55% 42.23% 21.20% 504 27.36% 72.64% 5.64% 44.32% 22.66%
440 30.93% 69.07% 5.55% 42.27% 21.22% 505 27.30% 72.70% 5.64% 44.35% 22.68%
441 30.88% 69.12% 5.55% 42.30% 21.24% 506 27.25% 72.75% 5.65% 44.39% 22.70%
442 30.82% 69.18% 5.56% 42.34% 21.27% 507 27.21% 72.79% 5.65% 44.41% 22.71%
443 30.76% 69.24% 5.56% 42.37% 21.29% 508 27.15% 72.85% 5.65% 44.45% 22.74%
444 30.70% 69.30% 5.56% 42.41% 21.31% 509 27.09% 72.92% 5.65% 44.48% 22.76%
445 30.64% 69.36% 5.56% 42.44% 21.34% 510 27.04% 72.96% 5.65% 44.51% 22.78%
446 30.58% 69.42% 5.56% 42.47% 21.37% 511 26.99% 73.01% 5.65% 44.54% 22.80%
447 30.52% 69.48% 5.56% 42.51% 21.40% 512 26.94% 73.06% 5.65% 44.57% 22.82%
448 30.46% 69.54% 5.56% 42.54% 21.42% 513 26.90% 73.10% 5.65% 44.60% 22.83%
449 30.39% 69.61% 5.57% 42.58% 21.45% 514 26.86% 73.14% 5.65% 44.62% 22.86%
450 30.33% 69.67% 5.57% 42.62% 21.47% 515 26.80% 73.20% 5.65% 44.65% 22.88%
451 30.26% 69.74% 5.57% 42.65% 21.50% 516 26.75% 73.25% 5.65% 44.68% 22.90%
452 30.21% 69.79% 5.57% 42.68% 21.52% 517 26.70% 73.30% 5.65% 44.70% 22.92%
453 30.15% 69.85% 5.57% 42.72% 21.54% 518 26.65% 73.35% 5.65% 44.73% 22.94%
454 30.09% 69.91% 5.58% 42.76% 21.56% 519 26.59% 73.41% 5.66% 44.77% 22.97%
455 30.04% 69.96% 5.58% 42.78% 21.58% 520 26.54% 73.46% 5.66% 44.79% 22.99%
456 29.99% 70.01% 5.58% 42.81% 21.60% 521 26.50% 73.50% 5.66% 44.82% 23.01%
457 29.93% 70.07% 5.58% 42.85% 21.63% 522 26.45% 73.55% 5.66% 44.84% 23.03%
458 29.87% 70.13% 5.58% 42.88% 21.65% 523 26.40% 73.60% 5.66% 44.87% 23.05%
459 29.83% 70.18% 5.58% 42.90% 21.67% 524 26.35% 73.65% 5.66% 44.90% 23.07%
460 29.77% 70.23% 5.58% 42.93% 21.69% 525 26.31% 73.69% 5.66% 44.92% 23.08%
461 29.72% 70.28% 5.59% 42.97% 21.71% 526 26.27% 73.73% 5.66% 44.95% 23.10%
462 29.66% 70.34% 5.59% 42.99% 21.73% 527 26.23% 73.77% 5.66% 44.96% 23.12%
463 29.61% 70.39% 5.59% 43.03% 21.75% 528 26.18% 73.82% 5.66% 45.00% 23.14%
464 29.54% 70.46% 5.59% 43.07% 21.78% 529 26.14% 73.86% 5.67% 45.02% 23.15%
465 29.48% 70.52% 5.59% 43.11% 21.80% 530 26.10% 73.90% 5.67% 45.05% 23.17%
466 29.42% 70.58% 5.60% 43.15% 21.81% 531 26.04% 73.96% 5.67% 45.08% 23.19%
467 29.36% 70.65% 5.60% 43.18% 21.84% 532 26.00% 74.00% 5.67% 45.11% 23.20%
468 29.30% 70.70% 5.60% 43.22% 21.87% 533 25.96% 74.04% 5.67% 45.13% 23.22%
469 29.25% 70.75% 5.60% 43.25% 21.88% 534 25.91% 74.09% 5.67% 45.15% 23.25%
470 29.20% 70.80% 5.60% 43.28% 21.90% 535 25.86% 74.14% 5.67% 45.18% 23.27%
471 29.13% 70.87% 5.60% 43.32% 21.92% 536 25.82% 74.18% 5.67% 45.20% 23.29%
472 29.08% 70.92% 5.61% 43.35% 21.94% 537 25.77% 74.23% 5.67% 45.23% 23.31%
473 29.02% 70.98% 5.61% 43.39% 21.96% 538 25.72% 74.28% 5.67% 45.25% 23.34%
184
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 539 25.68% 74.32% 5.67% 45.28% 23.35% 604 22.84% 77.16% 5.71% 46.95% 24.49%
540 25.63% 74.37% 5.67% 45.31% 23.37% 605 22.79% 77.21% 5.71% 46.97% 24.51%
541 25.60% 74.40% 5.67% 45.33% 23.39% 606 22.75% 77.25% 5.71% 46.99% 24.53%
542 25.55% 74.45% 5.67% 45.35% 23.40% 607 22.71% 77.29% 5.71% 47.02% 24.55%
543 25.50% 74.50% 5.67% 45.38% 23.43% 608 22.67% 77.33% 5.71% 47.04% 24.57%
544 25.45% 74.55% 5.67% 45.40% 23.45% 609 22.63% 77.38% 5.71% 47.06% 24.58%
545 25.40% 74.60% 5.67% 45.44% 23.47% 610 22.59% 77.41% 5.71% 47.08% 24.59%
546 25.35% 74.65% 5.68% 45.47% 23.49% 611 22.55% 77.45% 5.71% 47.10% 24.61%
547 25.30% 74.70% 5.68% 45.49% 23.51% 612 22.51% 77.49% 5.71% 47.12% 24.64%
548 25.25% 74.75% 5.68% 45.53% 23.53% 613 22.48% 77.52% 5.71% 47.14% 24.65%
549 25.21% 74.79% 5.68% 45.55% 23.55% 614 22.43% 77.57% 5.71% 47.17% 24.67%
550 25.16% 74.84% 5.68% 45.58% 23.56% 615 22.39% 77.61% 5.71% 47.19% 24.69%
551 25.12% 74.88% 5.68% 45.61% 23.57% 616 22.35% 77.65% 5.71% 47.21% 24.70%
552 25.06% 74.94% 5.68% 45.65% 23.60% 617 22.31% 77.69% 5.71% 47.24% 24.72%
553 25.01% 74.99% 5.68% 45.67% 23.62% 618 22.27% 77.73% 5.71% 47.26% 24.74%
554 24.96% 75.05% 5.68% 45.71% 23.64% 619 22.24% 77.76% 5.71% 47.28% 24.75%
555 24.90% 75.10% 5.68% 45.74% 23.66% 620 22.19% 77.81% 5.71% 47.31% 24.77%
556 24.87% 75.13% 5.68% 45.76% 23.67% 621 22.15% 77.85% 5.72% 47.33% 24.79%
557 24.82% 75.18% 5.68% 45.79% 23.69% 622 22.11% 77.89% 5.72% 47.35% 24.81%
558 24.77% 75.23% 5.68% 45.82% 23.71% 623 22.07% 77.93% 5.72% 47.37% 24.82%
559 24.73% 75.27% 5.68% 45.84% 23.73% 624 22.04% 77.96% 5.72% 47.39% 24.83%
560 24.68% 75.32% 5.68% 45.87% 23.75% 625 21.99% 78.01% 5.72% 47.42% 24.85%
561 24.64% 75.36% 5.68% 45.90% 23.76% 626 21.96% 78.05% 5.72% 47.43% 24.87%
562 24.60% 75.40% 5.68% 45.93% 23.77% 627 21.91% 78.09% 5.72% 47.45% 24.90%
563 24.56% 75.44% 5.68% 45.95% 23.79% 628 21.87% 78.13% 5.72% 47.47% 24.92%
564 24.52% 75.48% 5.68% 45.97% 23.80% 629 21.84% 78.16% 5.72% 47.49% 24.93%
565 24.48% 75.52% 5.68% 45.99% 23.82% 630 21.80% 78.20% 5.72% 47.52% 24.95%
566 24.44% 75.56% 5.69% 46.01% 23.85% 631 21.76% 78.24% 5.72% 47.54% 24.96%
567 24.40% 75.60% 5.69% 46.04% 23.86% 632 21.73% 78.27% 5.72% 47.56% 24.98%
568 24.35% 75.65% 5.69% 46.06% 23.88% 633 21.70% 78.30% 5.72% 47.57% 24.99%
569 24.31% 75.69% 5.69% 46.09% 23.90% 634 21.66% 78.34% 5.72% 47.59% 25.00%
570 24.27% 75.73% 5.69% 46.11% 23.91% 635 21.62% 78.38% 5.72% 47.62% 25.02%
571 24.22% 75.78% 5.69% 46.14% 23.93% 636 21.59% 78.41% 5.72% 47.64% 25.03%
572 24.19% 75.82% 5.69% 46.16% 23.94% 637 21.55% 78.45% 5.72% 47.67% 25.04%
573 24.14% 75.86% 5.69% 46.19% 23.96% 638 21.52% 78.48% 5.72% 47.68% 25.06%
574 24.09% 75.91% 5.69% 46.22% 23.97% 639 21.49% 78.51% 5.72% 47.70% 25.07%
575 24.05% 75.95% 5.69% 46.24% 23.99% 640 21.46% 78.54% 5.72% 47.71% 25.08%
576 24.01% 76.00% 5.69% 46.27% 24.01% 641 21.43% 78.57% 5.72% 47.74% 25.09%
577 23.96% 76.04% 5.69% 46.30% 24.03% 642 21.40% 78.61% 5.72% 47.76% 25.10%
578 23.91% 76.09% 5.69% 46.32% 24.05% 643 21.36% 78.64% 5.72% 47.78% 25.11%
579 23.88% 76.13% 5.70% 46.34% 24.07% 644 21.34% 78.67% 5.72% 47.79% 25.13%
580 23.83% 76.17% 5.70% 46.37% 24.08% 645 21.30% 78.70% 5.72% 47.81% 25.15%
581 23.78% 76.22% 5.70% 46.40% 24.10% 646 21.27% 78.73% 5.72% 47.83% 25.16%
582 23.75% 76.25% 5.70% 46.42% 24.12% 647 21.23% 78.77% 5.72% 47.85% 25.18%
583 23.71% 76.29% 5.70% 46.44% 24.13% 648 21.19% 78.81% 5.72% 47.87% 25.20%
584 23.66% 76.34% 5.70% 46.48% 24.15% 649 21.16% 78.84% 5.72% 47.89% 25.21%
585 23.61% 76.39% 5.70% 46.50% 24.17% 650 21.12% 78.89% 5.72% 47.91% 25.23%
586 23.57% 76.43% 5.70% 46.53% 24.18% 651 21.08% 78.92% 5.72% 47.93% 25.24%
587 23.52% 76.48% 5.70% 46.55% 24.20% 652 21.05% 78.95% 5.73% 47.95% 25.26%
588 23.47% 76.53% 5.70% 46.58% 24.22% 653 21.00% 79.00% 5.73% 47.97% 25.28%
589 23.42% 76.58% 5.70% 46.61% 24.24% 654 20.97% 79.03% 5.73% 47.99% 25.29%
590 23.38% 76.62% 5.70% 46.64% 24.26% 655 20.94% 79.06% 5.73% 48.01% 25.31%
591 23.35% 76.65% 5.70% 46.66% 24.27% 656 20.90% 79.10% 5.73% 48.03% 25.33%
592 23.30% 76.70% 5.70% 46.69% 24.30% 657 20.86% 79.14% 5.73% 48.05% 25.35%
593 23.25% 76.75% 5.70% 46.71% 24.31% 658 20.82% 79.18% 5.73% 48.07% 25.36%
594 23.21% 76.79% 5.70% 46.73% 24.34% 659 20.79% 79.21% 5.73% 48.09% 25.37%
595 23.17% 76.83% 5.70% 46.75% 24.35% 660 20.75% 79.25% 5.73% 48.11% 25.38%
596 23.14% 76.86% 5.70% 46.77% 24.37% 661 20.72% 79.28% 5.73% 48.14% 25.40%
597 23.10% 76.90% 5.70% 46.79% 24.39% 662 20.68% 79.32% 5.73% 48.16% 25.41%
598 23.07% 76.93% 5.70% 46.81% 24.40% 663 20.65% 79.35% 5.73% 48.17% 25.43%
599 23.02% 76.98% 5.71% 46.84% 24.42% 664 20.60% 79.40% 5.73% 48.20% 25.45%
600 22.98% 77.02% 5.71% 46.87% 24.43% 665 20.57% 79.43% 5.73% 48.22% 25.46%
601 22.95% 77.05% 5.71% 46.88% 24.45% 666 20.55% 79.46% 5.73% 48.23% 25.47%
602 22.91% 77.09% 5.71% 46.91% 24.46% 667 20.51% 79.49% 5.73% 48.25% 25.49%
603 22.87% 77.13% 5.71% 46.93% 24.48% 668 20.47% 79.53% 5.73% 48.28% 25.50%
185
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 669 20.44% 79.56% 5.73% 48.30% 25.51% 734 18.37% 81.63% 5.74% 49.47% 26.41%
670 20.40% 79.60% 5.73% 48.32% 25.53% 735 18.34% 81.66% 5.74% 49.48% 26.43%
671 20.35% 79.65% 5.73% 48.35% 25.55% 736 18.31% 81.69% 5.74% 49.49% 26.44%
672 20.31% 79.69% 5.73% 48.37% 25.57% 737 18.29% 81.71% 5.74% 49.51% 26.45%
673 20.27% 79.73% 5.73% 48.39% 25.59% 738 18.25% 81.75% 5.74% 49.53% 26.46%
674 20.24% 79.76% 5.73% 48.41% 25.60% 739 18.21% 81.79% 5.74% 49.55% 26.48%
675 20.20% 79.80% 5.73% 48.43% 25.63% 740 18.17% 81.83% 5.74% 49.57% 26.51%
676 20.17% 79.83% 5.73% 48.44% 25.64% 741 18.14% 81.86% 5.74% 49.59% 26.52%
677 20.14% 79.86% 5.73% 48.46% 25.65% 742 18.11% 81.89% 5.74% 49.61% 26.53%
678 20.10% 79.90% 5.73% 48.48% 25.66% 743 18.09% 81.92% 5.74% 49.62% 26.54%
679 20.07% 79.93% 5.73% 48.51% 25.67% 744 18.06% 81.94% 5.74% 49.63% 26.56%
680 20.02% 79.98% 5.73% 48.53% 25.69% 745 18.03% 81.97% 5.74% 49.64% 26.57%
681 19.99% 80.01% 5.73% 48.55% 25.70% 746 18.01% 82.00% 5.74% 49.66% 26.58%
682 19.96% 80.04% 5.73% 48.57% 25.71% 747 17.98% 82.02% 5.74% 49.67% 26.59%
683 19.92% 80.08% 5.73% 48.60% 25.73% 748 17.95% 82.05% 5.74% 49.69% 26.60%
684 19.89% 80.12% 5.73% 48.62% 25.74% 749 17.92% 82.08% 5.74% 49.71% 26.62%
685 19.86% 80.14% 5.73% 48.63% 25.75% 750 17.88% 82.12% 5.74% 49.74% 26.63%
686 19.82% 80.18% 5.73% 48.65% 25.77% 751 17.85% 82.15% 5.74% 49.76% 26.64%
687 19.79% 80.21% 5.73% 48.67% 25.79% 752 17.82% 82.18% 5.74% 49.77% 26.65%
688 19.75% 80.25% 5.73% 48.70% 25.80% 753 17.80% 82.20% 5.74% 49.78% 26.66%
689 19.71% 80.29% 5.73% 48.72% 25.81% 754 17.77% 82.23% 5.74% 49.80% 26.67%
690 19.69% 80.32% 5.74% 48.74% 25.83% 755 17.74% 82.26% 5.74% 49.81% 26.69%
691 19.66% 80.34% 5.74% 48.75% 25.84% 756 17.73% 82.27% 5.74% 49.82% 26.69%
692 19.62% 80.39% 5.74% 48.78% 25.85% 757 17.70% 82.30% 5.74% 49.83% 26.71%
693 19.58% 80.42% 5.74% 48.80% 25.87% 758 17.67% 82.33% 5.74% 49.85% 26.72%
694 19.55% 80.45% 5.74% 48.81% 25.88% 759 17.65% 82.35% 5.74% 49.86% 26.73%
695 19.53% 80.48% 5.74% 48.83% 25.89% 760 17.62% 82.38% 5.74% 49.89% 26.74%
696 19.50% 80.50% 5.74% 48.84% 25.90% 761 17.58% 82.42% 5.74% 49.91% 26.75%
697 19.47% 80.53% 5.74% 48.86% 25.92% 762 17.56% 82.44% 5.74% 49.92% 26.77%
698 19.44% 80.56% 5.74% 48.87% 25.93% 763 17.53% 82.48% 5.74% 49.94% 26.78%
699 19.41% 80.59% 5.74% 48.89% 25.95% 764 17.50% 82.50% 5.74% 49.95% 26.79%
700 19.38% 80.62% 5.74% 48.91% 25.96% 765 17.48% 82.52% 5.74% 49.97% 26.80%
701 19.34% 80.66% 5.74% 48.93% 25.97% 766 17.45% 82.55% 5.74% 49.99% 26.81%
702 19.31% 80.69% 5.74% 48.95% 25.98% 767 17.43% 82.58% 5.74% 50.00% 26.82%
703 19.28% 80.72% 5.74% 48.96% 26.00% 768 17.40% 82.60% 5.74% 50.02% 26.83%
704 19.26% 80.74% 5.74% 48.98% 26.01% 769 17.38% 82.63% 5.74% 50.03% 26.84%
705 19.23% 80.77% 5.74% 48.99% 26.03% 770 17.35% 82.65% 5.74% 50.05% 26.85%
706 19.20% 80.80% 5.74% 49.00% 26.04% 771 17.33% 82.67% 5.74% 50.06% 26.86%
707 19.17% 80.83% 5.74% 49.02% 26.05% 772 17.30% 82.70% 5.74% 50.08% 26.87%
708 19.14% 80.86% 5.74% 49.04% 26.07% 773 17.27% 82.73% 5.74% 50.09% 26.88%
709 19.10% 80.90% 5.74% 49.06% 26.08% 774 17.24% 82.76% 5.74% 50.11% 26.90%
710 19.06% 80.94% 5.74% 49.08% 26.10% 775 17.21% 82.79% 5.74% 50.13% 26.90%
711 19.05% 80.96% 5.74% 49.09% 26.11% 776 17.18% 82.82% 5.74% 50.14% 26.92%
712 19.02% 80.98% 5.74% 49.11% 26.12% 777 17.16% 82.84% 5.74% 50.15% 26.93%
713 18.99% 81.01% 5.74% 49.12% 26.13% 778 17.14% 82.86% 5.74% 50.17% 26.94%
714 18.96% 81.04% 5.74% 49.13% 26.15% 779 17.11% 82.89% 5.74% 50.18% 26.96%
715 18.94% 81.07% 5.74% 49.14% 26.17% 780 17.09% 82.91% 5.74% 50.19% 26.97%
716 18.90% 81.10% 5.74% 49.16% 26.18% 781 17.07% 82.93% 5.74% 50.20% 26.98%
717 18.86% 81.14% 5.74% 49.19% 26.20% 782 17.04% 82.96% 5.74% 50.22% 26.99%
718 18.83% 81.17% 5.74% 49.21% 26.21% 783 17.02% 82.98% 5.74% 50.23% 27.00%
719 18.80% 81.20% 5.74% 49.21% 26.23% 784 17.00% 83.00% 5.74% 50.24% 27.01%
720 18.78% 81.22% 5.74% 49.23% 26.24% 785 16.98% 83.03% 5.74% 50.25% 27.02%
721 18.74% 81.26% 5.74% 49.25% 26.25% 786 16.95% 83.05% 5.74% 50.27% 27.02%
722 18.71% 81.29% 5.74% 49.27% 26.26% 787 16.92% 83.08% 5.74% 50.29% 27.04%
723 18.68% 81.32% 5.74% 49.29% 26.28% 788 16.91% 83.09% 5.74% 50.30% 27.04%
724 18.66% 81.34% 5.74% 49.30% 26.29% 789 16.88% 83.12% 5.74% 50.31% 27.05%
725 18.63% 81.37% 5.74% 49.32% 26.30% 790 16.85% 83.15% 5.74% 50.33% 27.07%
726 18.61% 81.39% 5.74% 49.33% 26.31% 791 16.82% 83.18% 5.74% 50.35% 27.08%
727 18.58% 81.42% 5.74% 49.34% 26.32% 792 16.79% 83.21% 5.74% 50.36% 27.10%
728 18.54% 81.46% 5.74% 49.36% 26.34% 793 16.76% 83.24% 5.74% 50.38% 27.11%
729 18.51% 81.49% 5.74% 49.38% 26.35% 794 16.73% 83.27% 5.74% 50.39% 27.12%
730 18.49% 81.51% 5.74% 49.40% 26.36% 795 16.70% 83.30% 5.74% 50.41% 27.13%
731 18.46% 81.54% 5.74% 49.42% 26.37% 796 16.67% 83.33% 5.74% 50.43% 27.15%
732 18.42% 81.58% 5.74% 49.44% 26.39% 797 16.65% 83.35% 5.74% 50.44% 27.15%
733 18.39% 81.61% 5.74% 49.46% 26.40% 798 16.62% 83.38% 5.74% 50.46% 27.16%
186
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 799 16.59% 83.41% 5.74% 50.48% 27.18% 864 15.02% 84.98% 5.74% 51.31% 27.91%
800 16.56% 83.44% 5.74% 50.49% 27.19% 865 15.00% 85.00% 5.74% 51.32% 27.92%
801 16.54% 83.46% 5.74% 50.50% 27.20% 866 14.97% 85.03% 5.74% 51.34% 27.94%
802 16.51% 83.49% 5.74% 50.52% 27.21% 867 14.95% 85.05% 5.74% 51.35% 27.95%
803 16.48% 83.52% 5.74% 50.54% 27.23% 868 14.92% 85.08% 5.74% 51.36% 27.96%
804 16.46% 83.54% 5.74% 50.55% 27.23% 869 14.90% 85.10% 5.74% 51.37% 27.98%
805 16.45% 83.56% 5.74% 50.56% 27.24% 870 14.87% 85.14% 5.74% 51.39% 27.99%
806 16.43% 83.57% 5.74% 50.56% 27.25% 871 14.84% 85.16% 5.74% 51.40% 28.00%
807 16.41% 83.59% 5.74% 50.57% 27.27% 872 14.82% 85.18% 5.74% 51.41% 28.01%
808 16.38% 83.62% 5.74% 50.59% 27.28% 873 14.81% 85.19% 5.74% 51.42% 28.02%
809 16.35% 83.65% 5.74% 50.60% 27.29% 874 14.78% 85.22% 5.74% 51.44% 28.02%
810 16.33% 83.67% 5.74% 50.62% 27.30% 875 14.76% 85.24% 5.74% 51.45% 28.04%
811 16.31% 83.69% 5.74% 50.63% 27.31% 876 14.74% 85.26% 5.74% 51.46% 28.05%
812 16.28% 83.72% 5.74% 50.64% 27.33% 877 14.72% 85.29% 5.74% 51.47% 28.06%
813 16.26% 83.74% 5.74% 50.65% 27.33% 878 14.69% 85.31% 5.74% 51.48% 28.07%
814 16.23% 83.77% 5.74% 50.67% 27.34% 879 14.67% 85.33% 5.74% 51.50% 28.08%
815 16.20% 83.80% 5.74% 50.69% 27.35% 880 14.65% 85.36% 5.74% 51.51% 28.09%
816 16.18% 83.82% 5.74% 50.71% 27.36% 881 14.62% 85.38% 5.74% 51.52% 28.10%
817 16.15% 83.85% 5.74% 50.72% 27.37% 882 14.60% 85.40% 5.74% 51.53% 28.11%
818 16.12% 83.88% 5.74% 50.73% 27.39% 883 14.58% 85.42% 5.74% 51.55% 28.12%
819 16.10% 83.90% 5.74% 50.75% 27.40% 884 14.56% 85.44% 5.74% 51.56% 28.13%
820 16.08% 83.92% 5.74% 50.76% 27.41% 885 14.54% 85.46% 5.74% 51.57% 28.14%
821 16.07% 83.94% 5.74% 50.76% 27.42% 886 14.52% 85.49% 5.74% 51.58% 28.15%
822 16.03% 83.97% 5.74% 50.78% 27.43% 887 14.50% 85.50% 5.74% 51.59% 28.16%
823 16.01% 83.99% 5.74% 50.80% 27.44% 888 14.47% 85.53% 5.74% 51.61% 28.17%
824 15.99% 84.01% 5.74% 50.81% 27.45% 889 14.44% 85.56% 5.74% 51.63% 28.18%
825 15.97% 84.04% 5.74% 50.82% 27.46% 890 14.42% 85.58% 5.74% 51.64% 28.18%
826 15.95% 84.06% 5.74% 50.83% 27.47% 891 14.40% 85.60% 5.74% 51.66% 28.19%
827 15.92% 84.08% 5.74% 50.84% 27.48% 892 14.38% 85.62% 5.74% 51.67% 28.20%
828 15.89% 84.11% 5.74% 50.86% 27.50% 893 14.37% 85.64% 5.74% 51.67% 28.21%
829 15.87% 84.14% 5.74% 50.87% 27.51% 894 14.35% 85.65% 5.74% 51.68% 28.22%
830 15.83% 84.17% 5.74% 50.89% 27.52% 895 14.33% 85.67% 5.74% 51.69% 28.22%
831 15.80% 84.20% 5.74% 50.90% 27.54% 896 14.31% 85.69% 5.74% 51.71% 28.23%
832 15.78% 84.22% 5.74% 50.92% 27.55% 897 14.29% 85.71% 5.74% 51.72% 28.24%
833 15.75% 84.25% 5.74% 50.93% 27.56% 898 14.27% 85.73% 5.74% 51.73% 28.25%
834 15.74% 84.26% 5.74% 50.94% 27.57% 899 14.24% 85.76% 5.74% 51.74% 28.26%
835 15.71% 84.29% 5.74% 50.95% 27.58% 900 14.23% 85.77% 5.74% 51.74% 28.27%
836 15.69% 84.31% 5.74% 50.97% 27.59% 901 14.21% 85.79% 5.74% 51.75% 28.28%
837 15.67% 84.34% 5.74% 50.98% 27.60% 902 14.19% 85.81% 5.74% 51.77% 28.29%
838 15.63% 84.37% 5.74% 50.99% 27.62% 903 14.17% 85.83% 5.74% 51.78% 28.30%
839 15.61% 84.39% 5.74% 51.01% 27.63% 904 14.15% 85.85% 5.74% 51.79% 28.30%
840 15.59% 84.42% 5.74% 51.02% 27.64% 905 14.13% 85.87% 5.74% 51.80% 28.32%
841 15.56% 84.44% 5.74% 51.03% 27.65% 906 14.11% 85.90% 5.74% 51.81% 28.33%
842 15.55% 84.45% 5.74% 51.04% 27.66% 907 14.09% 85.91% 5.74% 51.82% 28.34%
843 15.52% 84.48% 5.74% 51.05% 27.67% 908 14.07% 85.93% 5.74% 51.83% 28.34%
844 15.50% 84.50% 5.74% 51.07% 27.68% 909 14.05% 85.95% 5.74% 51.84% 28.35%
845 15.47% 84.53% 5.74% 51.07% 27.70% 910 14.03% 85.98% 5.74% 51.85% 28.37%
846 15.45% 84.55% 5.74% 51.08% 27.72% 911 14.01% 85.99% 5.74% 51.86% 28.37%
847 15.42% 84.58% 5.74% 51.10% 27.73% 912 13.99% 86.01% 5.74% 51.87% 28.38%
848 15.39% 84.61% 5.74% 51.11% 27.74% 913 13.98% 86.03% 5.74% 51.88% 28.39%
849 15.37% 84.63% 5.74% 51.13% 27.75% 914 13.95% 86.05% 5.74% 51.89% 28.40%
850 15.35% 84.65% 5.74% 51.14% 27.76% 915 13.94% 86.06% 5.74% 51.90% 28.40%
851 15.32% 84.68% 5.74% 51.15% 27.77% 916 13.92% 86.08% 5.74% 51.91% 28.41%
852 15.31% 84.69% 5.74% 51.16% 27.78% 917 13.90% 86.10% 5.74% 51.92% 28.42%
853 15.28% 84.72% 5.74% 51.18% 27.79% 918 13.88% 86.12% 5.74% 51.93% 28.43%
854 15.25% 84.75% 5.74% 51.19% 27.81% 919 13.86% 86.14% 5.74% 51.94% 28.45%
855 15.24% 84.77% 5.74% 51.20% 27.81% 920 13.84% 86.16% 5.74% 51.95% 28.46%
856 15.21% 84.79% 5.74% 51.21% 27.83% 921 13.82% 86.18% 5.74% 51.96% 28.47%
857 15.19% 84.81% 5.74% 51.22% 27.84% 922 13.80% 86.20% 5.74% 51.97% 28.47%
858 15.16% 84.84% 5.74% 51.23% 27.85% 923 13.78% 86.22% 5.74% 51.98% 28.48%
859 15.13% 84.87% 5.74% 51.25% 27.86% 924 13.76% 86.24% 5.74% 51.99% 28.49%
860 15.10% 84.90% 5.74% 51.27% 27.87% 925 13.73% 86.27% 5.74% 52.01% 28.51%
861 15.08% 84.93% 5.74% 51.28% 27.89% 926 13.71% 86.29% 5.74% 52.02% 28.51%
862 15.06% 84.94% 5.74% 51.29% 27.90% 927 13.69% 86.31% 5.74% 52.04% 28.52%
863 15.04% 84.96% 5.74% 51.30% 27.90% 928 13.67% 86.34% 5.74% 52.05% 28.53%
187
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 929 13.65% 86.35% 5.74% 52.06% 28.54% 994 12.43% 87.57% 5.74% 52.74% 29.08%
930 13.62% 86.38% 5.74% 52.08% 28.55% 995 12.41% 87.59% 5.74% 52.75% 29.08%
931 13.59% 86.41% 5.74% 52.09% 28.56% 996 12.39% 87.61% 5.74% 52.76% 29.09%
932 13.58% 86.42% 5.74% 52.10% 28.57% 997 12.37% 87.63% 5.74% 52.77% 29.11%
933 13.56% 86.44% 5.74% 52.12% 28.57% 998 12.36% 87.65% 5.74% 52.78% 29.11%
934 13.53% 86.47% 5.74% 52.13% 28.58% 999 12.33% 87.67% 5.74% 52.79% 29.12%
935 13.51% 86.49% 5.74% 52.15% 28.59% 1000 12.31% 87.69% 5.74% 52.80% 29.13%
936 13.49% 86.51% 5.74% 52.16% 28.60% 1001 12.30% 87.70% 5.74% 52.81% 29.13%
937 13.47% 86.53% 5.74% 52.17% 28.60% 1002 12.29% 87.71% 5.74% 52.82% 29.14%
938 13.44% 86.56% 5.74% 52.18% 28.62% 1003 12.27% 87.73% 5.74% 52.83% 29.15%
939 13.42% 86.58% 5.74% 52.19% 28.63% 1004 12.26% 87.74% 5.74% 52.83% 29.15%
940 13.41% 86.59% 5.74% 52.20% 28.63% 1005 12.25% 87.75% 5.74% 52.84% 29.15%
941 13.40% 86.60% 5.74% 52.21% 28.64% 1006 12.22% 87.78% 5.74% 52.86% 29.16%
942 13.38% 86.62% 5.74% 52.22% 28.64% 1007 12.20% 87.80% 5.74% 52.87% 29.17%
943 13.37% 86.64% 5.74% 52.23% 28.65% 1008 12.18% 87.82% 5.74% 52.88% 29.18%
944 13.35% 86.65% 5.74% 52.24% 28.65% 1009 12.17% 87.83% 5.74% 52.89% 29.19%
945 13.33% 86.67% 5.74% 52.25% 28.66% 1010 12.15% 87.85% 5.74% 52.90% 29.19%
946 13.31% 86.69% 5.74% 52.26% 28.67% 1011 12.13% 87.87% 5.74% 52.91% 29.20%
947 13.30% 86.70% 5.74% 52.27% 28.68% 1012 12.10% 87.90% 5.74% 52.92% 29.22%
948 13.28% 86.72% 5.74% 52.28% 28.69% 1013 12.09% 87.92% 5.74% 52.93% 29.23%
949 13.25% 86.75% 5.74% 52.29% 28.70% 1014 12.08% 87.92% 5.74% 52.93% 29.24%
950 13.24% 86.76% 5.74% 52.30% 28.70% 1015 12.06% 87.94% 5.74% 52.94% 29.25%
951 13.22% 86.78% 5.74% 52.31% 28.71% 1016 12.04% 87.96% 5.74% 52.95% 29.25%
952 13.20% 86.80% 5.74% 52.32% 28.72% 1017 12.02% 87.98% 5.74% 52.96% 29.26%
953 13.18% 86.82% 5.74% 52.33% 28.73% 1018 12.01% 87.99% 5.74% 52.97% 29.27%
954 13.16% 86.84% 5.74% 52.34% 28.74% 1019 11.99% 88.01% 5.74% 52.98% 29.27%
955 13.14% 86.86% 5.74% 52.36% 28.75% 1020 11.98% 88.02% 5.74% 52.99% 29.27%
956 13.12% 86.88% 5.74% 52.37% 28.76% 1021 11.97% 88.03% 5.74% 52.99% 29.28%
957 13.09% 86.91% 5.74% 52.38% 28.77% 1022 11.96% 88.04% 5.74% 53.00% 29.29%
958 13.07% 86.93% 5.74% 52.39% 28.78% 1023 11.95% 88.05% 5.74% 53.01% 29.29%
959 13.05% 86.95% 5.74% 52.40% 28.79% 1024 11.93% 88.07% 5.74% 53.02% 29.30%
960 13.04% 86.96% 5.74% 52.41% 28.80% 1025 11.91% 88.09% 5.74% 53.03% 29.31%
961 13.02% 86.98% 5.74% 52.42% 28.80% 1026 11.90% 88.10% 5.74% 53.04% 29.31%
962 13.01% 86.99% 5.74% 52.42% 28.81% 1027 11.88% 88.12% 5.74% 53.05% 29.32%
963 12.99% 87.01% 5.74% 52.43% 28.82% 1028 11.86% 88.14% 5.74% 53.06% 29.32%
964 12.97% 87.03% 5.74% 52.44% 28.83% 1029 11.85% 88.15% 5.74% 53.07% 29.33%
965 12.96% 87.05% 5.74% 52.45% 28.84% 1030 11.83% 88.17% 5.74% 53.07% 29.34%
966 12.94% 87.06% 5.74% 52.46% 28.85% 1031 11.82% 88.18% 5.74% 53.08% 29.34%
967 12.91% 87.09% 5.74% 52.47% 28.86% 1032 11.80% 88.20% 5.74% 53.09% 29.35%
968 12.90% 87.10% 5.74% 52.48% 28.87% 1033 11.79% 88.21% 5.74% 53.10% 29.36%
969 12.88% 87.12% 5.74% 52.49% 28.88% 1034 11.78% 88.22% 5.74% 53.11% 29.36%
970 12.87% 87.13% 5.74% 52.50% 28.88% 1035 11.75% 88.25% 5.74% 53.12% 29.37%
971 12.86% 87.14% 5.74% 52.50% 28.88% 1036 11.73% 88.27% 5.74% 53.13% 29.38%
972 12.85% 87.15% 5.74% 52.51% 28.89% 1037 11.72% 88.28% 5.74% 53.14% 29.39%
973 12.83% 87.17% 5.74% 52.52% 28.89% 1038 11.70% 88.30% 5.74% 53.15% 29.40%
974 12.81% 87.19% 5.74% 52.53% 28.90% 1039 11.68% 88.32% 5.74% 53.16% 29.41%
975 12.80% 87.20% 5.74% 52.54% 28.91% 1040 11.66% 88.34% 5.74% 53.17% 29.42%
976 12.77% 87.23% 5.74% 52.56% 28.92% 1041 11.65% 88.35% 5.74% 53.18% 29.42%
977 12.75% 87.25% 5.74% 52.56% 28.93% 1042 11.63% 88.37% 5.74% 53.19% 29.43%
978 12.74% 87.26% 5.74% 52.57% 28.93% 1043 11.60% 88.40% 5.74% 53.21% 29.44%
979 12.72% 87.28% 5.74% 52.58% 28.95% 1044 11.58% 88.42% 5.74% 53.21% 29.45%
980 12.70% 87.30% 5.74% 52.59% 28.96% 1045 11.57% 88.43% 5.74% 53.22% 29.46%
981 12.68% 87.32% 5.74% 52.60% 28.96% 1046 11.56% 88.44% 5.74% 53.22% 29.46%
982 12.67% 87.33% 5.74% 52.61% 28.97% 1047 11.54% 88.47% 5.74% 53.23% 29.48%
983 12.64% 87.36% 5.74% 52.62% 28.98% 1048 11.52% 88.48% 5.74% 53.24% 29.48%
984 12.63% 87.37% 5.74% 52.63% 28.99% 1049 11.51% 88.50% 5.74% 53.25% 29.49%
985 12.61% 87.39% 5.74% 52.64% 29.00% 1050 11.49% 88.52% 5.74% 53.26% 29.50%
986 12.59% 87.42% 5.74% 52.65% 29.01% 1051 11.47% 88.53% 5.74% 53.27% 29.51%
987 12.56% 87.44% 5.74% 52.66% 29.02% 1052 11.45% 88.55% 5.74% 53.27% 29.52%
988 12.55% 87.45% 5.74% 52.67% 29.02% 1053 11.44% 88.56% 5.74% 53.28% 29.53%
989 12.54% 87.46% 5.74% 52.67% 29.03% 1054 11.42% 88.58% 5.74% 53.29% 29.54%
990 12.51% 87.49% 5.74% 52.69% 29.05% 1055 11.41% 88.59% 5.74% 53.29% 29.54%
991 12.49% 87.51% 5.74% 52.70% 29.05% 1056 11.39% 88.61% 5.74% 53.30% 29.55%
992 12.47% 87.53% 5.74% 52.71% 29.06% 1057 11.38% 88.62% 5.74% 53.31% 29.56%
993 12.45% 87.55% 5.74% 52.73% 29.07% 1058 11.37% 88.63% 5.74% 53.31% 29.56%
188
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 1059 11.35% 88.65% 5.74% 53.32% 29.57% 1124 10.43% 89.58% 5.74% 53.81% 30.01%
1060 11.33% 88.67% 5.74% 53.34% 29.58% 1125 10.41% 89.59% 5.74% 53.81% 30.02%
1061 11.32% 88.68% 5.74% 53.34% 29.58% 1126 10.40% 89.60% 5.74% 53.82% 30.03%
1062 11.31% 88.69% 5.74% 53.35% 29.59% 1127 10.39% 89.62% 5.74% 53.82% 30.04%
1063 11.30% 88.70% 5.74% 53.35% 29.59% 1128 10.37% 89.63% 5.74% 53.83% 30.04%
1064 11.29% 88.71% 5.74% 53.36% 29.60% 1129 10.36% 89.64% 5.74% 53.84% 30.05%
1065 11.28% 88.72% 5.74% 53.37% 29.60% 1130 10.35% 89.65% 5.74% 53.85% 30.05%
1066 11.26% 88.74% 5.74% 53.38% 29.61% 1131 10.34% 89.66% 5.74% 53.85% 30.06%
1067 11.24% 88.76% 5.74% 53.38% 29.62% 1132 10.32% 89.68% 5.74% 53.86% 30.07%
1068 11.23% 88.77% 5.74% 53.39% 29.62% 1133 10.31% 89.69% 5.74% 53.87% 30.07%
1069 11.22% 88.78% 5.74% 53.40% 29.63% 1134 10.29% 89.71% 5.74% 53.88% 30.07%
1070 11.20% 88.80% 5.74% 53.41% 29.63% 1135 10.28% 89.72% 5.74% 53.88% 30.08%
1071 11.19% 88.81% 5.74% 53.42% 29.64% 1136 10.27% 89.73% 5.74% 53.89% 30.08%
1072 11.18% 88.82% 5.74% 53.42% 29.64% 1137 10.26% 89.75% 5.74% 53.90% 30.09%
1073 11.16% 88.84% 5.74% 53.43% 29.65% 1138 10.24% 89.76% 5.74% 53.91% 30.09%
1074 11.15% 88.85% 5.74% 53.44% 29.66% 1139 10.23% 89.77% 5.74% 53.92% 30.10%
1075 11.14% 88.86% 5.74% 53.44% 29.67% 1140 10.22% 89.78% 5.74% 53.92% 30.11%
1076 11.13% 88.87% 5.74% 53.44% 29.67% 1141 10.20% 89.80% 5.74% 53.93% 30.11%
1077 11.12% 88.88% 5.74% 53.45% 29.68% 1142 10.19% 89.81% 5.74% 53.94% 30.12%
1078 11.10% 88.90% 5.74% 53.45% 29.69% 1143 10.18% 89.82% 5.74% 53.94% 30.13%
1079 11.09% 88.91% 5.74% 53.47% 29.69% 1144 10.16% 89.84% 5.74% 53.95% 30.13%
1080 11.07% 88.93% 5.74% 53.48% 29.70% 1145 10.15% 89.85% 5.74% 53.96% 30.14%
1081 11.05% 88.95% 5.74% 53.49% 29.71% 1146 10.13% 89.87% 5.74% 53.97% 30.14%
1082 11.04% 88.96% 5.74% 53.49% 29.71% 1147 10.12% 89.88% 5.74% 53.98% 30.15%
1083 11.02% 88.98% 5.74% 53.51% 29.72% 1148 10.11% 89.89% 5.74% 53.98% 30.15%
1084 11.01% 88.99% 5.74% 53.51% 29.72% 1149 10.10% 89.90% 5.74% 53.99% 30.16%
1085 11.00% 89.00% 5.74% 53.52% 29.73% 1150 10.09% 89.91% 5.74% 53.99% 30.16%
1086 10.99% 89.01% 5.74% 53.53% 29.73% 1151 10.08% 89.92% 5.74% 54.00% 30.17%
1087 10.98% 89.03% 5.74% 53.53% 29.74% 1152 10.07% 89.93% 5.74% 54.00% 30.17%
1088 10.96% 89.04% 5.74% 53.54% 29.74% 1153 10.05% 89.95% 5.74% 54.01% 30.19%
1089 10.95% 89.05% 5.74% 53.55% 29.75% 1154 10.04% 89.97% 5.74% 54.02% 30.19%
1090 10.94% 89.06% 5.74% 53.56% 29.75% 1155 10.02% 89.98% 5.74% 54.03% 30.20%
1091 10.93% 89.07% 5.74% 53.56% 29.76% 1156 10.01% 89.99% 5.74% 54.04% 30.20%
1092 10.92% 89.08% 5.74% 53.57% 29.76% 1157 9.99% 90.01% 5.74% 54.04% 30.21%
1093 10.91% 89.10% 5.74% 53.57% 29.77% 1158 9.97% 90.03% 5.74% 54.05% 30.22%
1094 10.89% 89.12% 5.74% 53.58% 29.78% 1159 9.95% 90.05% 5.74% 54.06% 30.23%
1095 10.87% 89.13% 5.74% 53.59% 29.79% 1160 9.94% 90.06% 5.74% 54.07% 30.24%
1096 10.85% 89.15% 5.74% 53.59% 29.80% 1161 9.92% 90.08% 5.74% 54.08% 30.24%
1097 10.84% 89.16% 5.74% 53.60% 29.81% 1162 9.91% 90.09% 5.74% 54.09% 30.25%
1098 10.82% 89.18% 5.74% 53.61% 29.81% 1163 9.90% 90.10% 5.74% 54.10% 30.25%
1099 10.80% 89.20% 5.74% 53.62% 29.82% 1164 9.89% 90.11% 5.74% 54.10% 30.26%
1100 10.79% 89.21% 5.74% 53.62% 29.83% 1165 9.87% 90.13% 5.74% 54.11% 30.27%
1101 10.78% 89.22% 5.74% 53.63% 29.84% 1166 9.85% 90.15% 5.74% 54.11% 30.28%
1102 10.76% 89.24% 5.74% 53.64% 29.85% 1167 9.84% 90.16% 5.74% 54.12% 30.28%
1103 10.74% 89.26% 5.74% 53.65% 29.86% 1168 9.83% 90.17% 5.74% 54.12% 30.30%
1104 10.72% 89.28% 5.74% 53.66% 29.87% 1169 9.82% 90.19% 5.74% 54.13% 30.30%
1105 10.71% 89.29% 5.74% 53.66% 29.88% 1170 9.81% 90.19% 5.74% 54.14% 30.30%
1106 10.69% 89.31% 5.74% 53.67% 29.89% 1171 9.79% 90.21% 5.74% 54.14% 30.31%
1107 10.68% 89.32% 5.74% 53.67% 29.89% 1172 9.78% 90.22% 5.74% 54.15% 30.31%
1108 10.66% 89.34% 5.74% 53.68% 29.90% 1173 9.77% 90.23% 5.74% 54.15% 30.32%
1109 10.65% 89.35% 5.74% 53.69% 29.91% 1174 9.76% 90.24% 5.74% 54.16% 30.32%
1110 10.63% 89.37% 5.74% 53.70% 29.91% 1175 9.75% 90.25% 5.74% 54.16% 30.33%
1111 10.61% 89.39% 5.74% 53.71% 29.93% 1176 9.74% 90.26% 5.74% 54.17% 30.33%
1112 10.60% 89.40% 5.74% 53.71% 29.93% 1177 9.73% 90.27% 5.74% 54.17% 30.34%
1113 10.59% 89.41% 5.74% 53.72% 29.94% 1178 9.72% 90.28% 5.74% 54.18% 30.35%
1114 10.58% 89.42% 5.74% 53.73% 29.94% 1179 9.71% 90.29% 5.74% 54.18% 30.36%
1115 10.55% 89.45% 5.74% 53.74% 29.95% 1180 9.69% 90.31% 5.74% 54.19% 30.36%
1116 10.54% 89.46% 5.74% 53.75% 29.96% 1181 9.68% 90.32% 5.74% 54.19% 30.37%
1117 10.53% 89.47% 5.74% 53.76% 29.96% 1182 9.67% 90.33% 5.74% 54.20% 30.38%
1118 10.51% 89.49% 5.74% 53.77% 29.97% 1183 9.66% 90.34% 5.74% 54.21% 30.38%
1119 10.50% 89.50% 5.74% 53.77% 29.97% 1184 9.64% 90.36% 5.74% 54.21% 30.39%
1120 10.49% 89.51% 5.74% 53.78% 29.97% 1185 9.63% 90.37% 5.74% 54.22% 30.40%
1121 10.48% 89.52% 5.74% 53.78% 29.98% 1186 9.62% 90.38% 5.74% 54.22% 30.40%
1122 10.47% 89.53% 5.74% 53.78% 29.99% 1187 9.61% 90.39% 5.74% 54.23% 30.41%
1123 10.44% 89.56% 5.74% 53.80% 30.00% 1188 9.60% 90.40% 5.74% 54.24% 30.41%
189
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 1189 9.59% 90.41% 5.74% 54.24% 30.42%
1190 9.58% 90.42% 5.74% 54.24% 30.42%
1191 9.57% 90.43% 5.74% 54.25% 30.42%
1192 9.56% 90.44% 5.74% 54.26% 30.43%
1193 9.55% 90.45% 5.74% 54.26% 30.43%
1194 9.54% 90.46% 5.74% 54.27% 30.44%
1195 9.53% 90.47% 5.74% 54.27% 30.44%
1196 9.51% 90.49% 5.74% 54.28% 30.45%
1197 9.50% 90.50% 5.74% 54.29% 30.46%
1198 9.49% 90.52% 5.74% 54.29% 30.47%
1199 9.48% 90.52% 5.74% 54.30% 30.47%
1200 9.46% 90.54% 5.74% 54.30% 30.48%
190
Table B5. LOCA Probability History for ASP-04 Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA for Days After TOD -312 97.54% 2.46% 2.46% 0.00% 0.00%
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA -311 97.53% 2.47% 2.47% 0.00% 0.00%
-365 98.21% 1.79% 1.79% 0.00% 0.00% -310 97.51% 2.49% 2.49% 0.00% 0.00%
-364 98.20% 1.80% 1.80% 0.00% 0.00% -309 97.49% 2.51% 2.51% 0.00% 0.00%
-363 98.19% 1.81% 1.81% 0.00% 0.00% -308 97.48% 2.52% 2.52% 0.00% 0.00%
-362 98.18% 1.82% 1.82% 0.00% 0.00% -307 97.46% 2.54% 2.54% 0.00% 0.00%
-361 98.17% 1.83% 1.83% 0.00% 0.00% -306 97.45% 2.55% 2.55% 0.00% 0.00%
-360 98.16% 1.84% 1.84% 0.00% 0.00% -305 97.44% 2.56% 2.56% 0.00% 0.00%
-359 98.15% 1.85% 1.85% 0.00% 0.00% -304 97.43% 2.57% 2.57% 0.00% 0.00%
-358 98.13% 1.87% 1.87% 0.00% 0.00% -303 97.41% 2.59% 2.59% 0.00% 0.00%
-357 98.12% 1.88% 1.88% 0.00% 0.00% -302 97.40% 2.60% 2.60% 0.00% 0.00%
-356 98.11% 1.89% 1.89% 0.00% 0.00% -301 97.39% 2.61% 2.61% 0.00% 0.00%
-355 98.10% 1.90% 1.90% 0.00% 0.00% -300 97.38% 2.62% 2.62% 0.00% 0.00%
-354 98.09% 1.91% 1.91% 0.00% 0.00% -299 97.36% 2.64% 2.64% 0.00% 0.00%
-353 98.08% 1.92% 1.92% 0.00% 0.00% -298 97.34% 2.66% 2.66% 0.00% 0.00%
-352 98.07% 1.93% 1.93% 0.00% 0.00% -297 97.32% 2.68% 2.68% 0.00% 0.00%
-351 98.06% 1.94% 1.94% 0.00% 0.00% -296 97.31% 2.69% 2.69% 0.00% 0.00%
-350 98.06% 1.94% 1.94% 0.00% 0.00% -295 97.30% 2.71% 2.71% 0.00% 0.00%
-349 98.05% 1.95% 1.95% 0.00% 0.00% -294 97.28% 2.72% 2.72% 0.00% 0.00%
-348 98.04% 1.96% 1.96% 0.00% 0.00% -293 97.26% 2.74% 2.74% 0.00% 0.00%
-347 98.02% 1.98% 1.98% 0.00% 0.00% -292 97.23% 2.77% 2.77% 0.00% 0.00%
-346 98.02% 1.98% 1.98% 0.00% 0.00% -291 97.21% 2.79% 2.79% 0.00% 0.00%
-345 98.00% 2.00% 2.00% 0.00% 0.00% -290 97.20% 2.80% 2.80% 0.00% 0.00%
-344 97.99% 2.01% 2.01% 0.00% 0.00% -289 97.18% 2.83% 2.83% 0.00% 0.00%
-343 97.98% 2.02% 2.02% 0.00% 0.00% -288 97.16% 2.85% 2.85% 0.00% 0.00%
-342 97.97% 2.03% 2.03% 0.00% 0.00% -287 97.14% 2.87% 2.87% 0.00% 0.00%
-341 97.95% 2.05% 2.05% 0.00% 0.00% -286 97.11% 2.89% 2.89% 0.00% 0.00%
-340 97.94% 2.06% 2.06% 0.00% 0.00% -285 97.09% 2.91% 2.91% 0.00% 0.00%
-339 97.93% 2.07% 2.07% 0.00% 0.00% -284 97.07% 2.93% 2.93% 0.00% 0.00%
-338 97.91% 2.09% 2.09% 0.00% 0.00% -283 97.05% 2.95% 2.95% 0.00% 0.00%
-337 97.90% 2.10% 2.10% 0.00% 0.00% -282 97.04% 2.97% 2.97% 0.00% 0.00%
-336 97.88% 2.12% 2.12% 0.00% 0.00% -281 97.02% 2.98% 2.98% 0.00% 0.00%
-335 97.87% 2.13% 2.13% 0.00% 0.00% -280 97.01% 2.99% 2.99% 0.00% 0.00%
-334 97.86% 2.14% 2.14% 0.00% 0.00% -279 96.98% 3.02% 3.02% 0.00% 0.00%
-333 97.85% 2.15% 2.15% 0.00% 0.00% -278 96.97% 3.03% 3.03% 0.00% 0.00%
-332 97.84% 2.17% 2.17% 0.00% 0.00% -277 96.95% 3.05% 3.05% 0.00% 0.00%
-331 97.83% 2.18% 2.18% 0.00% 0.00% -276 96.93% 3.07% 3.07% 0.00% 0.00%
-330 97.81% 2.19% 2.19% 0.00% 0.00% -275 96.90% 3.10% 3.10% 0.00% 0.00%
-329 97.80% 2.20% 2.20% 0.00% 0.00% -274 96.88% 3.12% 3.12% 0.00% 0.00%
-328 97.79% 2.21% 2.21% 0.00% 0.00% -273 96.87% 3.13% 3.13% 0.00% 0.00%
-327 97.78% 2.22% 2.22% 0.00% 0.00% -272 96.85% 3.15% 3.15% 0.00% 0.00%
-326 97.77% 2.23% 2.23% 0.00% 0.00% -271 96.84% 3.17% 3.17% 0.00% 0.00%
-325 97.75% 2.25% 2.25% 0.00% 0.00% -270 96.81% 3.20% 3.20% 0.00% 0.00%
-324 97.74% 2.26% 2.26% 0.00% 0.00% -269 96.79% 3.22% 3.22% 0.00% 0.00%
-323 97.72% 2.28% 2.28% 0.00% 0.00% -268 96.76% 3.24% 3.24% 0.00% 0.00%
-322 97.70% 2.30% 2.30% 0.00% 0.00% -267 96.74% 3.26% 3.26% 0.00% 0.00%
-321 97.68% 2.32% 2.32% 0.00% 0.00% -266 96.72% 3.28% 3.28% 0.00% 0.00%
-320 97.67% 2.33% 2.33% 0.00% 0.00% -265 96.70% 3.30% 3.30% 0.00% 0.00%
-319 97.65% 2.36% 2.36% 0.00% 0.00% -264 96.68% 3.32% 3.32% 0.00% 0.00%
-318 97.63% 2.38% 2.38% 0.00% 0.00% -263 96.66% 3.34% 3.34% 0.00% 0.00%
-317 97.62% 2.39% 2.39% 0.00% 0.00% -262 96.64% 3.36% 3.36% 0.00% 0.00%
-316 97.60% 2.40% 2.40% 0.00% 0.00% -261 96.62% 3.38% 3.38% 0.00% 0.00%
-315 97.59% 2.41% 2.41% 0.00% 0.00% -260 96.60% 3.40% 3.40% 0.00% 0.00%
-314 97.58% 2.43% 2.43% 0.00% 0.00% -259 96.58% 3.42% 3.42% 0.00% 0.00%
-313 97.56% 2.44% 2.44% 0.00% 0.00% -258 96.57% 3.43% 3.43% 0.00% 0.00%
191
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA
-257 96.54% 3.46% 3.46% 0.00% 0.00% -202 95.04% 4.96% 4.96% 0.00% 0.00%
-256 96.52% 3.48% 3.48% 0.00% 0.00% -201 95.01% 4.99% 4.99% 0.00% 0.00%
-255 96.50% 3.50% 3.50% 0.00% 0.00% -200 94.98% 5.02% 5.01% 0.00% 0.00%
-254 96.48% 3.52% 3.52% 0.00% 0.00% -199 94.95% 5.05% 5.05% 0.00% 0.00%
-253 96.45% 3.55% 3.55% 0.00% 0.00% -198 94.91% 5.09% 5.08% 0.00% 0.01%
-252 96.43% 3.57% 3.57% 0.00% 0.00% -197 94.87% 5.13% 5.13% 0.00% 0.01%
-251 96.41% 3.60% 3.60% 0.00% 0.00% -196 94.83% 5.17% 5.16% 0.00% 0.01%
-250 96.38% 3.62% 3.62% 0.00% 0.00% -195 94.79% 5.21% 5.20% 0.00% 0.01%
-249 96.37% 3.63% 3.63% 0.00% 0.00% -194 94.77% 5.24% 5.23% 0.00% 0.01%
-248 96.35% 3.65% 3.65% 0.00% 0.00% -193 94.73% 5.27% 5.26% 0.00% 0.01%
-247 96.33% 3.67% 3.67% 0.00% 0.00% -192 94.70% 5.30% 5.29% 0.00% 0.01%
-246 96.31% 3.69% 3.69% 0.00% 0.00% -191 94.67% 5.33% 5.32% 0.00% 0.01%
-245 96.29% 3.72% 3.72% 0.00% 0.00% -190 94.63% 5.37% 5.36% 0.00% 0.01%
-244 96.27% 3.73% 3.73% 0.00% 0.00% -189 94.61% 5.40% 5.39% 0.00% 0.01%
-243 96.24% 3.76% 3.76% 0.00% 0.00% -188 94.56% 5.44% 5.43% 0.00% 0.01%
-242 96.22% 3.78% 3.78% 0.00% 0.00% -187 94.53% 5.47% 5.46% 0.01% 0.01%
-241 96.20% 3.80% 3.80% 0.00% 0.00% -186 94.49% 5.51% 5.50% 0.01% 0.01%
-240 96.19% 3.82% 3.82% 0.00% 0.00% -185 94.46% 5.54% 5.53% 0.01% 0.01%
-239 96.16% 3.84% 3.84% 0.00% 0.00% -184 94.43% 5.57% 5.56% 0.01% 0.01%
-238 96.14% 3.86% 3.86% 0.00% 0.00% -183 94.39% 5.61% 5.59% 0.01% 0.01%
-237 96.11% 3.89% 3.89% 0.00% 0.00% -182 94.36% 5.64% 5.62% 0.01% 0.01%
-236 96.08% 3.92% 3.92% 0.00% 0.00% -181 94.32% 5.68% 5.66% 0.01% 0.01%
-235 96.06% 3.95% 3.94% 0.00% 0.00% -180 94.29% 5.71% 5.69% 0.01% 0.01%
-234 96.03% 3.97% 3.97% 0.00% 0.00% -179 94.25% 5.75% 5.73% 0.01% 0.01%
-233 96.00% 4.00% 4.00% 0.00% 0.00% -178 94.21% 5.79% 5.77% 0.01% 0.01%
-232 95.96% 4.05% 4.04% 0.00% 0.00% -177 94.17% 5.83% 5.81% 0.01% 0.01%
-231 95.93% 4.07% 4.07% 0.00% 0.00% -176 94.13% 5.87% 5.85% 0.01% 0.01%
-230 95.91% 4.09% 4.09% 0.00% 0.00% -175 94.09% 5.91% 5.89% 0.01% 0.02%
-229 95.88% 4.12% 4.12% 0.00% 0.00% -174 94.04% 5.96% 5.94% 0.01% 0.02%
-228 95.85% 4.15% 4.15% 0.00% 0.00% -173 94.00% 6.00% 5.98% 0.01% 0.02%
-227 95.83% 4.17% 4.17% 0.00% 0.00% -172 93.95% 6.05% 6.02% 0.01% 0.02%
-226 95.80% 4.20% 4.20% 0.00% 0.00% -171 93.90% 6.10% 6.07% 0.01% 0.02%
-225 95.78% 4.23% 4.22% 0.00% 0.00% -170 93.86% 6.14% 6.11% 0.01% 0.02%
-224 95.74% 4.26% 4.26% 0.00% 0.00% -169 93.82% 6.18% 6.15% 0.01% 0.02%
-223 95.72% 4.28% 4.28% 0.00% 0.00% -168 93.78% 6.22% 6.19% 0.01% 0.02%
-222 95.69% 4.31% 4.31% 0.00% 0.00% -167 93.72% 6.28% 6.25% 0.02% 0.02%
-221 95.66% 4.34% 4.34% 0.00% 0.00% -166 93.68% 6.32% 6.29% 0.02% 0.02%
-220 95.63% 4.37% 4.37% 0.00% 0.00% -165 93.64% 6.37% 6.33% 0.02% 0.02%
-219 95.60% 4.41% 4.40% 0.00% 0.00% -164 93.59% 6.41% 6.37% 0.02% 0.02%
-218 95.57% 4.43% 4.43% 0.00% 0.00% -163 93.56% 6.44% 6.41% 0.02% 0.02%
-217 95.53% 4.47% 4.47% 0.00% 0.00% -162 93.52% 6.48% 6.45% 0.02% 0.02%
-216 95.50% 4.50% 4.50% 0.00% 0.00% -161 93.48% 6.52% 6.48% 0.02% 0.02%
-215 95.47% 4.53% 4.53% 0.00% 0.00% -160 93.44% 6.56% 6.52% 0.02% 0.02%
-214 95.44% 4.57% 4.56% 0.00% 0.00% -159 93.40% 6.60% 6.57% 0.02% 0.02%
-213 95.41% 4.59% 4.59% 0.00% 0.00% -158 93.36% 6.64% 6.61% 0.02% 0.02%
-212 95.37% 4.63% 4.63% 0.00% 0.00% -157 93.31% 6.69% 6.65% 0.02% 0.02%
-211 95.34% 4.66% 4.66% 0.00% 0.00% -156 93.28% 6.72% 6.68% 0.02% 0.02%
-210 95.31% 4.69% 4.69% 0.00% 0.00% -155 93.24% 6.76% 6.72% 0.02% 0.02%
-209 95.27% 4.73% 4.72% 0.00% 0.00% -154 93.20% 6.80% 6.76% 0.02% 0.02%
-208 95.26% 4.74% 4.74% 0.00% 0.00% -153 93.17% 6.83% 6.79% 0.02% 0.02%
-207 95.22% 4.78% 4.77% 0.00% 0.00% -152 93.13% 6.87% 6.83% 0.02% 0.02%
-206 95.18% 4.82% 4.82% 0.00% 0.00% -151 93.08% 6.92% 6.88% 0.02% 0.02%
-205 95.15% 4.85% 4.85% 0.00% 0.00% -150 93.04% 6.96% 6.91% 0.02% 0.02%
-204 95.11% 4.89% 4.88% 0.00% 0.00% -149 93.00% 7.00% 6.95% 0.02% 0.03%
-203 95.08% 4.92% 4.92% 0.00% 0.00% -148 92.95% 7.05% 7.00% 0.02% 0.03%
192
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA
-147 92.90% 7.10% 7.05% 0.02% 0.03% -92 89.85% 10.15% 10.00% 0.06% 0.09%
-146 92.87% 7.13% 7.09% 0.02% 0.03% -91 89.78% 10.23% 10.08% 0.06% 0.09%
-145 92.83% 7.18% 7.13% 0.02% 0.03% -90 89.70% 10.30% 10.14% 0.07% 0.09%
-144 92.78% 7.23% 7.18% 0.02% 0.03% -89 89.65% 10.36% 10.20% 0.07% 0.09%
-143 92.73% 7.27% 7.22% 0.02% 0.03% -88 89.58% 10.42% 10.25% 0.07% 0.10%
-142 92.68% 7.32% 7.27% 0.02% 0.03% -87 89.52% 10.49% 10.32% 0.07% 0.10%
-141 92.64% 7.36% 7.31% 0.02% 0.03% -86 89.45% 10.55% 10.38% 0.07% 0.10%
-140 92.59% 7.41% 7.36% 0.02% 0.03% -85 89.36% 10.64% 10.46% 0.07% 0.11%
-139 92.54% 7.46% 7.41% 0.02% 0.03% -84 89.31% 10.70% 10.52% 0.07% 0.11%
-138 92.48% 7.52% 7.47% 0.02% 0.03% -83 89.23% 10.78% 10.59% 0.07% 0.11%
-137 92.43% 7.57% 7.52% 0.03% 0.03% -82 89.16% 10.84% 10.65% 0.07% 0.12%
-136 92.38% 7.62% 7.57% 0.03% 0.03% -81 89.09% 10.91% 10.71% 0.08% 0.12%
-135 92.32% 7.68% 7.62% 0.03% 0.03% -80 89.02% 10.99% 10.78% 0.08% 0.12%
-134 92.27% 7.73% 7.67% 0.03% 0.03% -79 88.95% 11.05% 10.84% 0.08% 0.13%
-133 92.21% 7.79% 7.73% 0.03% 0.03% -78 88.90% 11.11% 10.89% 0.08% 0.13%
-132 92.15% 7.85% 7.79% 0.03% 0.03% -77 88.83% 11.17% 10.96% 0.09% 0.13%
-131 92.11% 7.89% 7.83% 0.03% 0.03% -76 88.75% 11.25% 11.03% 0.09% 0.13%
-130 92.07% 7.94% 7.87% 0.03% 0.04% -75 88.69% 11.31% 11.09% 0.09% 0.14%
-129 92.01% 7.99% 7.92% 0.03% 0.04% -74 88.61% 11.39% 11.16% 0.09% 0.14%
-128 91.97% 8.04% 7.97% 0.03% 0.04% -73 88.53% 11.47% 11.23% 0.09% 0.15%
-127 91.91% 8.09% 8.02% 0.03% 0.04% -72 88.46% 11.54% 11.30% 0.09% 0.15%
-126 91.85% 8.15% 8.08% 0.03% 0.04% -71 88.39% 11.61% 11.36% 0.10% 0.15%
-125 91.80% 8.20% 8.13% 0.03% 0.04% -70 88.32% 11.68% 11.43% 0.10% 0.16%
-124 91.74% 8.26% 8.19% 0.03% 0.04% -69 88.25% 11.75% 11.50% 0.10% 0.16%
-123 91.67% 8.33% 8.25% 0.04% 0.04% -68 88.18% 11.82% 11.55% 0.10% 0.17%
-122 91.63% 8.37% 8.29% 0.04% 0.04% -67 88.10% 11.90% 11.63% 0.10% 0.17%
-121 91.58% 8.43% 8.35% 0.04% 0.04% -66 88.03% 11.97% 11.70% 0.10% 0.17%
-120 91.52% 8.48% 8.40% 0.04% 0.04% -65 87.96% 12.05% 11.76% 0.11% 0.18%
-119 91.46% 8.54% 8.46% 0.04% 0.04% -64 87.89% 12.11% 11.83% 0.11% 0.18%
-118 91.40% 8.60% 8.52% 0.04% 0.04% -63 87.81% 12.19% 11.89% 0.11% 0.19%
-117 91.35% 8.65% 8.57% 0.04% 0.04% -62 87.74% 12.26% 11.96% 0.11% 0.19%
-116 91.28% 8.72% 8.63% 0.04% 0.05% -61 87.66% 12.34% 12.04% 0.11% 0.20%
-115 91.22% 8.78% 8.69% 0.04% 0.05% -60 87.57% 12.43% 12.12% 0.11% 0.20%
-114 91.17% 8.83% 8.74% 0.04% 0.05% -59 87.49% 12.52% 12.20% 0.11% 0.20%
-113 91.12% 8.88% 8.79% 0.04% 0.05% -58 87.39% 12.61% 12.28% 0.12% 0.21%
-112 91.07% 8.93% 8.84% 0.05% 0.05% -57 87.33% 12.68% 12.35% 0.12% 0.21%
-111 91.00% 9.00% 8.90% 0.05% 0.05% -56 87.24% 12.76% 12.43% 0.12% 0.21%
-110 90.96% 9.05% 8.94% 0.05% 0.06% -55 87.17% 12.83% 12.50% 0.12% 0.22%
-109 90.90% 9.10% 9.00% 0.05% 0.06% -54 87.10% 12.90% 12.56% 0.12% 0.22%
-108 90.85% 9.15% 9.05% 0.05% 0.06% -53 87.04% 12.96% 12.62% 0.12% 0.23%
-107 90.79% 9.21% 9.10% 0.05% 0.06% -52 86.96% 13.04% 12.70% 0.12% 0.23%
-106 90.73% 9.27% 9.16% 0.05% 0.06% -51 86.87% 13.13% 12.77% 0.12% 0.24%
-105 90.66% 9.34% 9.23% 0.05% 0.06% -50 86.79% 13.21% 12.85% 0.12% 0.24%
-104 90.61% 9.39% 9.28% 0.05% 0.06% -49 86.72% 13.29% 12.91% 0.13% 0.25%
-103 90.55% 9.45% 9.33% 0.05% 0.07% -48 86.62% 13.38% 13.00% 0.13% 0.25%
-102 90.51% 9.50% 9.37% 0.05% 0.07% -47 86.53% 13.47% 13.09% 0.13% 0.25%
-101 90.45% 9.55% 9.42% 0.06% 0.07% -46 86.46% 13.55% 13.15% 0.13% 0.26%
-100 90.39% 9.61% 9.48% 0.06% 0.07% -45 86.38% 13.62% 13.22% 0.13% 0.26%
-99 90.33% 9.67% 9.54% 0.06% 0.07% -44 86.31% 13.69% 13.29% 0.14% 0.27%
-98 90.27% 9.73% 9.60% 0.06% 0.07% -43 86.22% 13.78% 13.36% 0.14% 0.28%
-97 90.21% 9.79% 9.65% 0.06% 0.08% -42 86.13% 13.87% 13.45% 0.14% 0.28%
-96 90.13% 9.87% 9.73% 0.06% 0.08% -41 86.05% 13.95% 13.52% 0.14% 0.29%
-95 90.07% 9.93% 9.79% 0.06% 0.08% -40 85.96% 14.04% 13.60% 0.15% 0.30%
-94 89.99% 10.01% 9.86% 0.06% 0.08% -39 85.87% 14.13% 13.68% 0.15% 0.30%
-93 89.92% 10.08% 9.94% 0.06% 0.09% -38 85.78% 14.22% 13.77% 0.15% 0.30%
193
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA
-37 85.70% 14.30% 13.84% 0.15% 0.31% 18 80.34% 19.66% 18.55% 0.31% 0.80%
-36 85.61% 14.39% 13.92% 0.16% 0.31% 19 80.22% 19.78% 18.65% 0.31% 0.82%
-35 85.53% 14.47% 13.99% 0.16% 0.32% 20 80.10% 19.90% 18.76% 0.32% 0.83%
-34 85.45% 14.55% 14.07% 0.16% 0.32% 21 79.96% 20.04% 18.88% 0.32% 0.84%
-33 85.36% 14.64% 14.15% 0.16% 0.33% 22 79.85% 20.15% 18.97% 0.32% 0.86%
-32 85.27% 14.73% 14.23% 0.17% 0.33% 23 79.72% 20.28% 19.08% 0.33% 0.87%
-31 85.17% 14.83% 14.32% 0.17% 0.34% 24 79.61% 20.39% 19.17% 0.33% 0.89%
-30 85.08% 14.92% 14.40% 0.17% 0.35% 25 79.49% 20.51% 19.27% 0.34% 0.90%
-29 84.99% 15.01% 14.49% 0.17% 0.35% 26 79.38% 20.62% 19.36% 0.34% 0.91%
-28 84.89% 15.11% 14.58% 0.18% 0.36% 27 79.26% 20.74% 19.47% 0.35% 0.92%
-27 84.82% 15.18% 14.64% 0.18% 0.37% 28 79.14% 20.86% 19.57% 0.35% 0.94%
-26 84.73% 15.27% 14.73% 0.18% 0.37% 29 79.02% 20.98% 19.67% 0.36% 0.95%
-25 84.63% 15.37% 14.81% 0.18% 0.38% 30 78.92% 21.09% 19.77% 0.36% 0.96%
-24 84.54% 15.46% 14.88% 0.18% 0.39% 31 78.82% 21.18% 19.85% 0.36% 0.97%
-23 84.46% 15.54% 14.95% 0.19% 0.40% 32 78.69% 21.31% 19.96% 0.37% 0.99%
-22 84.38% 15.62% 15.03% 0.19% 0.41% 33 78.58% 21.43% 20.05% 0.37% 1.00%
-21 84.28% 15.72% 15.11% 0.19% 0.41% 34 78.46% 21.54% 20.15% 0.37% 1.02%
-20 84.18% 15.82% 15.21% 0.20% 0.42% 35 78.34% 21.66% 20.25% 0.37% 1.04%
-19 84.10% 15.90% 15.28% 0.20% 0.42% 36 78.23% 21.77% 20.34% 0.38% 1.06%
-18 84.02% 15.98% 15.35% 0.20% 0.43% 37 78.12% 21.88% 20.44% 0.38% 1.07%
-17 83.91% 16.09% 15.45% 0.20% 0.45% 38 77.99% 22.01% 20.55% 0.38% 1.08%
-16 83.81% 16.19% 15.53% 0.21% 0.46% 39 77.88% 22.12% 20.64% 0.39% 1.09%
-15 83.73% 16.27% 15.61% 0.21% 0.46% 40 77.77% 22.23% 20.74% 0.39% 1.11%
-14 83.64% 16.36% 15.69% 0.21% 0.47% 41 77.65% 22.35% 20.83% 0.40% 1.12%
-13 83.54% 16.46% 15.78% 0.21% 0.47% 42 77.53% 22.47% 20.93% 0.40% 1.14%
-12 83.44% 16.56% 15.87% 0.21% 0.48% 43 77.42% 22.58% 21.03% 0.41% 1.15%
-11 83.36% 16.64% 15.94% 0.21% 0.49% 44 77.29% 22.71% 21.12% 0.41% 1.17%
-10 83.26% 16.75% 16.03% 0.22% 0.50% 45 77.17% 22.83% 21.23% 0.42% 1.19%
-9 83.16% 16.84% 16.12% 0.22% 0.51% 46 77.05% 22.95% 21.33% 0.42% 1.20%
-8 83.06% 16.94% 16.21% 0.22% 0.51% 47 76.91% 23.09% 21.44% 0.43% 1.22%
-7 82.97% 17.03% 16.30% 0.22% 0.51% 48 76.80% 23.20% 21.53% 0.44% 1.24%
-6 82.85% 17.15% 16.40% 0.23% 0.52% 49 76.68% 23.32% 21.63% 0.44% 1.26%
-5 82.75% 17.25% 16.49% 0.23% 0.53% 50 76.54% 23.46% 21.74% 0.45% 1.27%
-4 82.64% 17.36% 16.59% 0.23% 0.54% 51 76.44% 23.56% 21.82% 0.45% 1.29%
-3 82.55% 17.46% 16.67% 0.23% 0.55% 52 76.32% 23.68% 21.92% 0.45% 1.31%
-2 82.43% 17.57% 16.78% 0.24% 0.56% 53 76.21% 23.79% 22.01% 0.46% 1.32%
-1 82.33% 17.67% 16.86% 0.24% 0.57% 54 76.07% 23.93% 22.12% 0.46% 1.35%
0 82.18% 17.82% 16.95% 0.24% 0.63% 55 75.94% 24.06% 22.23% 0.47% 1.37%
1 82.08% 17.93% 17.04% 0.25% 0.64% 56 75.82% 24.18% 22.33% 0.47% 1.38%
2 81.96% 18.04% 17.15% 0.25% 0.65% 57 75.70% 24.30% 22.43% 0.47% 1.40%
3 81.85% 18.15% 17.24% 0.25% 0.66% 58 75.57% 24.43% 22.54% 0.48% 1.41%
4 81.76% 18.24% 17.32% 0.25% 0.67% 59 75.45% 24.55% 22.64% 0.49% 1.43%
5 81.65% 18.35% 17.42% 0.26% 0.68% 60 75.32% 24.68% 22.74% 0.49% 1.44%
6 81.54% 18.46% 17.51% 0.26% 0.69% 61 75.21% 24.79% 22.83% 0.50% 1.46%
7 81.44% 18.56% 17.60% 0.27% 0.69% 62 75.08% 24.92% 22.94% 0.50% 1.48%
8 81.34% 18.66% 17.69% 0.27% 0.71% 63 74.98% 25.03% 23.02% 0.51% 1.50%
9 81.25% 18.75% 17.77% 0.27% 0.71% 64 74.85% 25.16% 23.13% 0.51% 1.51%
10 81.15% 18.85% 17.86% 0.27% 0.72% 65 74.71% 25.29% 23.25% 0.51% 1.53%
11 81.04% 18.96% 17.96% 0.28% 0.73% 66 74.57% 25.43% 23.37% 0.52% 1.55%
12 80.94% 19.06% 18.04% 0.28% 0.74% 67 74.44% 25.56% 23.48% 0.52% 1.56%
13 80.85% 19.15% 18.11% 0.29% 0.75% 68 74.33% 25.67% 23.57% 0.52% 1.58%
14 80.77% 19.24% 18.19% 0.29% 0.76% 69 74.19% 25.81% 23.68% 0.53% 1.60%
15 80.65% 19.35% 18.29% 0.29% 0.77% 70 74.07% 25.93% 23.78% 0.54% 1.62%
16 80.53% 19.47% 18.39% 0.30% 0.78% 71 73.96% 26.05% 23.87% 0.54% 1.63%
17 80.44% 19.56% 18.47% 0.30% 0.79% 72 73.82% 26.18% 23.98% 0.55% 1.66%
194
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 73 73.70% 26.30% 24.07% 0.55% 1.68% 128 66.62% 33.38% 29.69% 0.81% 2.89%
74 73.57% 26.44% 24.19% 0.56% 1.70% 129 66.48% 33.52% 29.78% 0.82% 2.92%
75 73.43% 26.57% 24.30% 0.56% 1.71% 130 66.36% 33.64% 29.88% 0.83% 2.94%
76 73.29% 26.71% 24.41% 0.56% 1.74% 131 66.22% 33.78% 29.97% 0.83% 2.98%
77 73.16% 26.84% 24.51% 0.57% 1.76% 132 66.10% 33.90% 30.06% 0.84% 3.01%
78 73.04% 26.96% 24.61% 0.58% 1.78% 133 65.97% 34.03% 30.15% 0.84% 3.04%
79 72.89% 27.11% 24.73% 0.58% 1.79% 134 65.83% 34.17% 30.25% 0.85% 3.07%
80 72.75% 27.25% 24.84% 0.58% 1.82% 135 65.70% 34.30% 30.35% 0.85% 3.10%
81 72.64% 27.36% 24.93% 0.59% 1.84% 136 65.59% 34.41% 30.44% 0.86% 3.11%
82 72.52% 27.49% 25.03% 0.60% 1.85% 137 65.47% 34.53% 30.54% 0.86% 3.14%
83 72.38% 27.62% 25.15% 0.61% 1.87% 138 65.34% 34.66% 30.64% 0.86% 3.17%
84 72.26% 27.74% 25.25% 0.61% 1.88% 139 65.22% 34.78% 30.72% 0.87% 3.19%
85 72.13% 27.87% 25.35% 0.62% 1.90% 140 65.09% 34.91% 30.82% 0.87% 3.22%
86 71.99% 28.01% 25.46% 0.62% 1.92% 141 64.96% 35.05% 30.92% 0.88% 3.25%
87 71.87% 28.13% 25.56% 0.63% 1.94% 142 64.84% 35.16% 31.01% 0.88% 3.27%
88 71.74% 28.26% 25.67% 0.63% 1.96% 143 64.71% 35.29% 31.11% 0.89% 3.30%
89 71.61% 28.39% 25.77% 0.64% 1.99% 144 64.59% 35.41% 31.19% 0.89% 3.33%
90 71.48% 28.52% 25.87% 0.64% 2.01% 145 64.47% 35.53% 31.27% 0.90% 3.36%
91 71.35% 28.65% 25.97% 0.65% 2.04% 146 64.36% 35.64% 31.36% 0.91% 3.38%
92 71.23% 28.77% 26.07% 0.65% 2.06% 147 64.24% 35.77% 31.45% 0.91% 3.40%
93 71.10% 28.90% 26.17% 0.66% 2.07% 148 64.11% 35.90% 31.55% 0.92% 3.43%
94 71.00% 29.00% 26.25% 0.66% 2.09% 149 63.97% 36.03% 31.64% 0.93% 3.46%
95 70.87% 29.13% 26.36% 0.66% 2.11% 150 63.83% 36.17% 31.75% 0.93% 3.49%
96 70.73% 29.27% 26.48% 0.67% 2.13% 151 63.71% 36.29% 31.84% 0.94% 3.52%
97 70.57% 29.43% 26.60% 0.67% 2.16% 152 63.59% 36.41% 31.93% 0.94% 3.54%
98 70.45% 29.55% 26.70% 0.68% 2.18% 153 63.45% 36.55% 32.03% 0.95% 3.57%
99 70.34% 29.66% 26.78% 0.68% 2.20% 154 63.34% 36.66% 32.12% 0.95% 3.60%
100 70.21% 29.79% 26.88% 0.69% 2.21% 155 63.22% 36.78% 32.21% 0.95% 3.62%
101 70.08% 29.92% 26.99% 0.70% 2.23% 156 63.08% 36.92% 32.32% 0.96% 3.65%
102 69.96% 30.04% 27.09% 0.70% 2.25% 157 62.98% 37.03% 32.39% 0.96% 3.67%
103 69.85% 30.15% 27.18% 0.71% 2.27% 158 62.85% 37.15% 32.49% 0.97% 3.70%
104 69.73% 30.27% 27.28% 0.71% 2.28% 159 62.73% 37.27% 32.57% 0.97% 3.73%
105 69.60% 30.40% 27.39% 0.71% 2.30% 160 62.61% 37.39% 32.66% 0.97% 3.76%
106 69.47% 30.53% 27.50% 0.72% 2.32% 161 62.48% 37.52% 32.76% 0.97% 3.79%
107 69.36% 30.64% 27.58% 0.72% 2.34% 162 62.35% 37.65% 32.87% 0.98% 3.81%
108 69.23% 30.77% 27.67% 0.73% 2.37% 163 62.22% 37.78% 32.97% 0.98% 3.83%
109 69.10% 30.90% 27.78% 0.73% 2.39% 164 62.09% 37.91% 33.06% 0.99% 3.86%
110 68.98% 31.02% 27.87% 0.74% 2.42% 165 61.97% 38.03% 33.15% 0.99% 3.89%
111 68.86% 31.14% 27.97% 0.74% 2.44% 166 61.85% 38.16% 33.24% 0.99% 3.92%
112 68.72% 31.28% 28.08% 0.74% 2.46% 167 61.74% 38.26% 33.32% 1.00% 3.94%
113 68.58% 31.42% 28.18% 0.75% 2.49% 168 61.62% 38.38% 33.40% 1.01% 3.97%
114 68.45% 31.55% 28.29% 0.75% 2.51% 169 61.51% 38.49% 33.48% 1.01% 4.00%
115 68.31% 31.69% 28.38% 0.76% 2.55% 170 61.38% 38.62% 33.57% 1.02% 4.03%
116 68.17% 31.83% 28.49% 0.76% 2.58% 171 61.28% 38.72% 33.65% 1.02% 4.05%
117 68.04% 31.96% 28.59% 0.77% 2.61% 172 61.15% 38.85% 33.75% 1.02% 4.07%
118 67.91% 32.09% 28.68% 0.77% 2.64% 173 61.01% 38.99% 33.86% 1.04% 4.10%
119 67.79% 32.21% 28.76% 0.78% 2.67% 174 60.88% 39.12% 33.95% 1.04% 4.13%
120 67.66% 32.34% 28.87% 0.78% 2.69% 175 60.75% 39.25% 34.04% 1.04% 4.16%
121 67.54% 32.46% 28.96% 0.79% 2.71% 176 60.63% 39.37% 34.14% 1.05% 4.19%
122 67.40% 32.60% 29.07% 0.79% 2.74% 177 60.50% 39.50% 34.23% 1.05% 4.22%
123 67.28% 32.72% 29.17% 0.79% 2.76% 178 60.38% 39.62% 34.32% 1.05% 4.25%
124 67.15% 32.85% 29.28% 0.80% 2.78% 179 60.26% 39.74% 34.41% 1.06% 4.27%
125 67.02% 32.99% 29.38% 0.80% 2.80% 180 60.13% 39.87% 34.51% 1.07% 4.30%
126 66.89% 33.11% 29.48% 0.80% 2.83% 181 60.00% 40.00% 34.60% 1.08% 4.33%
127 66.75% 33.25% 29.59% 0.81% 2.85% 182 59.89% 40.11% 34.67% 1.08% 4.36%
195
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 183 59.78% 40.22% 34.76% 1.08% 4.38% 238 53.61% 46.39% 39.34% 1.28% 5.78%
184 59.68% 40.32% 34.84% 1.09% 4.40% 239 53.47% 46.53% 39.43% 1.28% 5.81%
185 59.58% 40.43% 34.91% 1.09% 4.43% 240 53.38% 46.62% 39.51% 1.29% 5.82%
186 59.47% 40.53% 34.99% 1.09% 4.45% 241 53.28% 46.72% 39.59% 1.29% 5.84%
187 59.35% 40.65% 35.09% 1.10% 4.46% 242 53.18% 46.83% 39.67% 1.30% 5.87%
188 59.24% 40.76% 35.18% 1.10% 4.48% 243 53.07% 46.93% 39.75% 1.30% 5.89%
189 59.12% 40.88% 35.27% 1.11% 4.50% 244 52.96% 47.04% 39.82% 1.30% 5.92%
190 59.00% 41.00% 35.36% 1.11% 4.54% 245 52.86% 47.15% 39.90% 1.31% 5.94%
191 58.87% 41.14% 35.45% 1.12% 4.56% 246 52.76% 47.24% 39.97% 1.31% 5.96%
192 58.76% 41.24% 35.54% 1.12% 4.58% 247 52.65% 47.35% 40.06% 1.31% 5.98%
193 58.63% 41.37% 35.64% 1.12% 4.61% 248 52.54% 47.46% 40.14% 1.31% 6.01%
194 58.52% 41.48% 35.72% 1.13% 4.63% 249 52.46% 47.55% 40.20% 1.32% 6.03%
195 58.42% 41.58% 35.80% 1.13% 4.64% 250 52.35% 47.65% 40.27% 1.32% 6.06%
196 58.30% 41.71% 35.90% 1.14% 4.67% 251 52.25% 47.75% 40.34% 1.32% 6.09%
197 58.17% 41.83% 36.00% 1.14% 4.69% 252 52.15% 47.85% 40.41% 1.33% 6.11%
198 58.03% 41.97% 36.10% 1.15% 4.72% 253 52.04% 47.96% 40.50% 1.33% 6.13%
199 57.92% 42.08% 36.18% 1.15% 4.74% 254 51.93% 48.07% 40.57% 1.33% 6.16%
200 57.80% 42.20% 36.28% 1.15% 4.77% 255 51.83% 48.17% 40.65% 1.34% 6.19%
201 57.68% 42.32% 36.35% 1.16% 4.81% 256 51.74% 48.26% 40.71% 1.34% 6.21%
202 57.57% 42.43% 36.43% 1.16% 4.83% 257 51.65% 48.35% 40.78% 1.34% 6.23%
203 57.46% 42.54% 36.52% 1.16% 4.86% 258 51.55% 48.45% 40.85% 1.35% 6.26%
204 57.35% 42.65% 36.61% 1.17% 4.88% 259 51.45% 48.55% 40.92% 1.35% 6.28%
205 57.25% 42.75% 36.69% 1.17% 4.90% 260 51.35% 48.65% 40.99% 1.35% 6.31%
206 57.12% 42.88% 36.78% 1.17% 4.93% 261 51.25% 48.75% 41.07% 1.35% 6.33%
207 57.01% 42.99% 36.86% 1.17% 4.95% 262 51.13% 48.87% 41.15% 1.36% 6.36%
208 56.91% 43.09% 36.94% 1.18% 4.97% 263 51.03% 48.97% 41.22% 1.36% 6.40%
209 56.81% 43.19% 37.02% 1.18% 5.00% 264 50.94% 49.06% 41.28% 1.36% 6.41%
210 56.69% 43.31% 37.11% 1.18% 5.02% 265 50.83% 49.17% 41.35% 1.37% 6.45%
211 56.57% 43.43% 37.19% 1.18% 5.06% 266 50.73% 49.27% 41.42% 1.38% 6.47%
212 56.46% 43.55% 37.28% 1.18% 5.08% 267 50.63% 49.37% 41.49% 1.38% 6.50%
213 56.35% 43.65% 37.35% 1.19% 5.11% 268 50.54% 49.47% 41.57% 1.38% 6.52%
214 56.25% 43.75% 37.43% 1.19% 5.13% 269 50.43% 49.57% 41.65% 1.39% 6.54%
215 56.14% 43.86% 37.51% 1.20% 5.16% 270 50.33% 49.67% 41.72% 1.39% 6.57%
216 56.03% 43.97% 37.59% 1.20% 5.18% 271 50.23% 49.77% 41.78% 1.40% 6.58%
217 55.92% 44.08% 37.67% 1.20% 5.21% 272 50.14% 49.86% 41.85% 1.40% 6.61%
218 55.81% 44.19% 37.74% 1.21% 5.24% 273 50.03% 49.97% 41.93% 1.41% 6.64%
219 55.70% 44.30% 37.83% 1.21% 5.26% 274 49.92% 50.08% 42.00% 1.41% 6.67%
220 55.59% 44.42% 37.91% 1.22% 5.29% 275 49.84% 50.17% 42.06% 1.41% 6.69%
221 55.47% 44.53% 38.00% 1.22% 5.32% 276 49.72% 50.28% 42.16% 1.42% 6.70%
222 55.36% 44.64% 38.07% 1.22% 5.35% 277 49.62% 50.38% 42.23% 1.42% 6.73%
223 55.25% 44.75% 38.16% 1.23% 5.36% 278 49.51% 50.49% 42.30% 1.42% 6.77%
224 55.16% 44.84% 38.23% 1.23% 5.39% 279 49.41% 50.59% 42.37% 1.43% 6.79%
225 55.06% 44.94% 38.29% 1.23% 5.42% 280 49.31% 50.69% 42.44% 1.43% 6.82%
226 54.96% 45.04% 38.36% 1.24% 5.44% 281 49.23% 50.77% 42.49% 1.43% 6.84%
227 54.85% 45.15% 38.44% 1.24% 5.47% 282 49.13% 50.87% 42.57% 1.44% 6.87%
228 54.75% 45.26% 38.52% 1.24% 5.50% 283 49.04% 50.96% 42.63% 1.44% 6.89%
229 54.65% 45.35% 38.58% 1.25% 5.52% 284 48.94% 51.06% 42.69% 1.44% 6.92%
230 54.53% 45.47% 38.67% 1.25% 5.55% 285 48.85% 51.15% 42.76% 1.45% 6.95%
231 54.41% 45.59% 38.76% 1.26% 5.58% 286 48.74% 51.26% 42.85% 1.45% 6.97%
232 54.28% 45.73% 38.86% 1.26% 5.61% 287 48.65% 51.35% 42.90% 1.45% 7.00%
233 54.17% 45.83% 38.93% 1.26% 5.63% 288 48.56% 51.44% 42.97% 1.45% 7.02%
234 54.05% 45.95% 39.02% 1.26% 5.67% 289 48.47% 51.53% 43.04% 1.46% 7.04%
235 53.94% 46.07% 39.10% 1.27% 5.70% 290 48.38% 51.63% 43.10% 1.46% 7.06%
236 53.83% 46.17% 39.18% 1.27% 5.73% 291 48.29% 51.71% 43.16% 1.46% 7.09%
237 53.71% 46.29% 39.25% 1.28% 5.76% 292 48.21% 51.79% 43.22% 1.46% 7.11%
196
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 293 48.12% 51.88% 43.27% 1.47% 7.14% 348 43.39% 56.62% 46.58% 1.64% 8.39%
294 48.03% 51.97% 43.33% 1.47% 7.17% 349 43.30% 56.70% 46.64% 1.64% 8.42%
295 47.94% 52.06% 43.39% 1.47% 7.20% 350 43.20% 56.80% 46.71% 1.64% 8.45%
296 47.86% 52.14% 43.45% 1.48% 7.22% 351 43.11% 56.89% 46.77% 1.65% 8.48%
297 47.77% 52.23% 43.51% 1.48% 7.24% 352 43.05% 56.95% 46.81% 1.65% 8.49%
298 47.67% 52.33% 43.58% 1.48% 7.26% 353 42.96% 57.04% 46.87% 1.65% 8.51%
299 47.59% 52.41% 43.64% 1.49% 7.29% 354 42.88% 57.12% 46.92% 1.65% 8.54%
300 47.50% 52.50% 43.71% 1.49% 7.30% 355 42.81% 57.19% 46.97% 1.66% 8.56%
301 47.43% 52.57% 43.75% 1.49% 7.32% 356 42.74% 57.26% 47.02% 1.66% 8.58%
302 47.34% 52.66% 43.82% 1.49% 7.35% 357 42.68% 57.32% 47.06% 1.66% 8.60%
303 47.26% 52.74% 43.87% 1.50% 7.37% 358 42.61% 57.39% 47.11% 1.66% 8.62%
304 47.18% 52.82% 43.92% 1.50% 7.39% 359 42.54% 57.46% 47.16% 1.67% 8.64%
305 47.10% 52.90% 43.98% 1.51% 7.41% 360 42.45% 57.55% 47.22% 1.67% 8.66%
306 47.00% 53.00% 44.06% 1.51% 7.44% 361 42.36% 57.64% 47.28% 1.67% 8.69%
307 46.93% 53.07% 44.11% 1.51% 7.45% 362 42.28% 57.72% 47.33% 1.68% 8.71%
308 46.84% 53.16% 44.17% 1.51% 7.48% 363 42.21% 57.79% 47.38% 1.68% 8.74%
309 46.76% 53.24% 44.22% 1.51% 7.51% 364 42.12% 57.88% 47.43% 1.68% 8.77%
310 46.66% 53.34% 44.29% 1.52% 7.53% 365 42.06% 57.94% 47.48% 1.69% 8.78%
311 46.57% 53.43% 44.36% 1.52% 7.55% 366 41.99% 58.01% 47.52% 1.69% 8.80%
312 46.46% 53.54% 44.43% 1.52% 7.59% 367 41.93% 58.07% 47.56% 1.69% 8.83%
313 46.36% 53.64% 44.51% 1.53% 7.61% 368 41.85% 58.15% 47.61% 1.70% 8.85%
314 46.28% 53.72% 44.56% 1.53% 7.63% 369 41.78% 58.22% 47.65% 1.70% 8.87%
315 46.18% 53.82% 44.63% 1.54% 7.66% 370 41.69% 58.31% 47.72% 1.70% 8.89%
316 46.10% 53.91% 44.70% 1.54% 7.67% 371 41.62% 58.38% 47.76% 1.70% 8.91%
317 46.00% 54.00% 44.76% 1.54% 7.69% 372 41.54% 58.46% 47.82% 1.71% 8.93%
318 45.92% 54.08% 44.82% 1.54% 7.71% 373 41.46% 58.54% 47.88% 1.71% 8.95%
319 45.84% 54.17% 44.88% 1.55% 7.74% 374 41.37% 58.63% 47.94% 1.71% 8.98%
320 45.74% 54.26% 44.95% 1.56% 7.76% 375 41.30% 58.70% 48.00% 1.71% 9.00%
321 45.66% 54.34% 45.00% 1.56% 7.78% 376 41.21% 58.79% 48.05% 1.72% 9.02%
322 45.58% 54.42% 45.06% 1.57% 7.80% 377 41.14% 58.86% 48.10% 1.72% 9.04%
323 45.51% 54.49% 45.10% 1.57% 7.82% 378 41.06% 58.94% 48.15% 1.72% 9.06%
324 45.43% 54.57% 45.16% 1.58% 7.84% 379 41.00% 59.00% 48.20% 1.73% 9.08%
325 45.35% 54.66% 45.22% 1.58% 7.86% 380 40.93% 59.07% 48.25% 1.73% 9.10%
326 45.27% 54.73% 45.27% 1.58% 7.88% 381 40.86% 59.14% 48.30% 1.73% 9.12%
327 45.20% 54.81% 45.32% 1.58% 7.90% 382 40.76% 59.24% 48.35% 1.74% 9.15%
328 45.11% 54.89% 45.38% 1.58% 7.93% 383 40.69% 59.32% 48.41% 1.74% 9.17%
329 45.02% 54.98% 45.43% 1.58% 7.96% 384 40.61% 59.39% 48.46% 1.74% 9.19%
330 44.93% 55.07% 45.50% 1.59% 7.99% 385 40.53% 59.47% 48.51% 1.75% 9.21%
331 44.84% 55.16% 45.56% 1.59% 8.01% 386 40.46% 59.54% 48.55% 1.75% 9.24%
332 44.76% 55.25% 45.62% 1.60% 8.03% 387 40.39% 59.61% 48.60% 1.75% 9.26%
333 44.67% 55.33% 45.68% 1.60% 8.05% 388 40.32% 59.68% 48.65% 1.75% 9.28%
334 44.59% 55.41% 45.73% 1.60% 8.08% 389 40.24% 59.76% 48.70% 1.76% 9.30%
335 44.50% 55.50% 45.79% 1.60% 8.10% 390 40.18% 59.82% 48.75% 1.76% 9.32%
336 44.42% 55.58% 45.86% 1.61% 8.12% 391 40.10% 59.90% 48.80% 1.76% 9.34%
337 44.34% 55.67% 45.92% 1.61% 8.14% 392 40.02% 59.98% 48.86% 1.76% 9.36%
338 44.24% 55.76% 45.99% 1.61% 8.17% 393 39.95% 60.05% 48.91% 1.76% 9.38%
339 44.15% 55.85% 46.06% 1.61% 8.18% 394 39.88% 60.12% 48.96% 1.77% 9.39%
340 44.08% 55.92% 46.11% 1.61% 8.20% 395 39.80% 60.20% 49.02% 1.77% 9.41%
341 43.99% 56.02% 46.18% 1.62% 8.22% 396 39.74% 60.26% 49.06% 1.77% 9.42%
342 43.91% 56.09% 46.23% 1.62% 8.24% 397 39.67% 60.33% 49.11% 1.77% 9.44%
343 43.82% 56.18% 46.29% 1.62% 8.26% 398 39.61% 60.39% 49.15% 1.77% 9.47%
344 43.74% 56.26% 46.35% 1.63% 8.29% 399 39.54% 60.46% 49.20% 1.78% 9.49%
345 43.66% 56.34% 46.40% 1.63% 8.32% 400 39.46% 60.54% 49.25% 1.78% 9.51%
346 43.55% 56.45% 46.47% 1.63% 8.35% 401 39.38% 60.62% 49.30% 1.78% 9.53%
347 43.48% 56.52% 46.53% 1.64% 8.36% 402 39.33% 60.67% 49.34% 1.79% 9.54%
197
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 403 39.27% 60.73% 49.38% 1.79% 9.56% 458 35.70% 64.30% 51.78% 1.92% 10.60%
404 39.22% 60.78% 49.42% 1.79% 9.58% 459 35.64% 64.36% 51.82% 1.92% 10.62%
405 39.16% 60.85% 49.46% 1.79% 9.60% 460 35.58% 64.42% 51.85% 1.92% 10.64%
406 39.08% 60.93% 49.52% 1.80% 9.61% 461 35.51% 64.49% 51.89% 1.93% 10.67%
407 39.01% 60.99% 49.56% 1.80% 9.63% 462 35.44% 64.56% 51.94% 1.93% 10.69%
408 38.94% 61.06% 49.61% 1.80% 9.65% 463 35.39% 64.61% 51.98% 1.93% 10.70%
409 38.87% 61.13% 49.66% 1.81% 9.67% 464 35.32% 64.68% 52.03% 1.93% 10.72%
410 38.81% 61.19% 49.70% 1.81% 9.69% 465 35.27% 64.73% 52.07% 1.93% 10.73%
411 38.75% 61.26% 49.74% 1.81% 9.70% 466 35.21% 64.79% 52.11% 1.93% 10.75%
412 38.67% 61.33% 49.80% 1.82% 9.72% 467 35.15% 64.85% 52.14% 1.93% 10.77%
413 38.61% 61.39% 49.84% 1.82% 9.73% 468 35.10% 64.90% 52.18% 1.94% 10.78%
414 38.55% 61.45% 49.88% 1.82% 9.75% 469 35.05% 64.95% 52.22% 1.94% 10.80%
415 38.50% 61.50% 49.91% 1.82% 9.77% 470 34.98% 65.02% 52.27% 1.94% 10.81%
416 38.43% 61.57% 49.96% 1.82% 9.79% 471 34.92% 65.08% 52.31% 1.94% 10.83%
417 38.36% 61.64% 50.01% 1.82% 9.80% 472 34.85% 65.15% 52.35% 1.95% 10.85%
418 38.28% 61.72% 50.07% 1.83% 9.83% 473 34.78% 65.22% 52.40% 1.95% 10.88%
419 38.20% 61.80% 50.12% 1.83% 9.85% 474 34.71% 65.29% 52.44% 1.95% 10.90%
420 38.12% 61.88% 50.18% 1.83% 9.88% 475 34.65% 65.35% 52.48% 1.95% 10.92%
421 38.06% 61.95% 50.22% 1.83% 9.90% 476 34.58% 65.42% 52.52% 1.95% 10.94%
422 37.99% 62.01% 50.26% 1.83% 9.92% 477 34.52% 65.48% 52.56% 1.96% 10.96%
423 37.95% 62.05% 50.29% 1.83% 9.93% 478 34.46% 65.54% 52.60% 1.96% 10.98%
424 37.88% 62.12% 50.33% 1.84% 9.95% 479 34.41% 65.59% 52.64% 1.96% 10.99%
425 37.81% 62.19% 50.39% 1.84% 9.97% 480 34.37% 65.63% 52.67% 1.96% 11.00%
426 37.76% 62.24% 50.43% 1.84% 9.98% 481 34.31% 65.69% 52.71% 1.96% 11.02%
427 37.69% 62.31% 50.48% 1.84% 10.00% 482 34.25% 65.75% 52.75% 1.96% 11.04%
428 37.62% 62.38% 50.52% 1.85% 10.02% 483 34.17% 65.83% 52.80% 1.96% 11.06%
429 37.55% 62.45% 50.57% 1.85% 10.03% 484 34.12% 65.88% 52.84% 1.97% 11.08%
430 37.46% 62.54% 50.63% 1.85% 10.06% 485 34.06% 65.94% 52.88% 1.97% 11.10%
431 37.40% 62.60% 50.68% 1.85% 10.07% 486 34.00% 66.00% 52.92% 1.97% 11.11%
432 37.34% 62.66% 50.72% 1.85% 10.09% 487 33.94% 66.06% 52.96% 1.97% 11.12%
433 37.27% 62.73% 50.76% 1.86% 10.11% 488 33.87% 66.13% 53.01% 1.98% 11.14%
434 37.20% 62.80% 50.82% 1.86% 10.13% 489 33.82% 66.18% 53.05% 1.98% 11.16%
435 37.15% 62.85% 50.85% 1.86% 10.14% 490 33.76% 66.24% 53.08% 1.98% 11.17%
436 37.09% 62.91% 50.89% 1.86% 10.16% 491 33.71% 66.29% 53.12% 1.98% 11.19%
437 37.03% 62.97% 50.93% 1.86% 10.18% 492 33.67% 66.33% 53.15% 1.98% 11.21%
438 36.97% 63.04% 50.98% 1.87% 10.20% 493 33.61% 66.40% 53.19% 1.98% 11.22%
439 36.91% 63.09% 51.01% 1.87% 10.21% 494 33.55% 66.45% 53.23% 1.99% 11.24%
440 36.84% 63.16% 51.05% 1.87% 10.24% 495 33.49% 66.51% 53.26% 1.99% 11.26%
441 36.78% 63.22% 51.09% 1.87% 10.25% 496 33.44% 66.56% 53.29% 1.99% 11.29%
442 36.72% 63.29% 51.13% 1.88% 10.28% 497 33.36% 66.64% 53.34% 1.99% 11.32%
443 36.64% 63.36% 51.18% 1.88% 10.30% 498 33.30% 66.70% 53.38% 1.99% 11.33%
444 36.58% 63.42% 51.22% 1.88% 10.32% 499 33.23% 66.77% 53.42% 2.00% 11.36%
445 36.52% 63.48% 51.26% 1.88% 10.34% 500 33.17% 66.84% 53.46% 2.00% 11.38%
446 36.46% 63.55% 51.30% 1.89% 10.36% 501 33.11% 66.89% 53.50% 2.00% 11.40%
447 36.39% 63.61% 51.34% 1.89% 10.38% 502 33.06% 66.94% 53.53% 2.00% 11.41%
448 36.33% 63.67% 51.38% 1.89% 10.40% 503 33.00% 67.00% 53.57% 2.00% 11.43%
449 36.27% 63.73% 51.41% 1.90% 10.42% 504 32.95% 67.05% 53.61% 2.00% 11.44%
450 36.21% 63.79% 51.45% 1.90% 10.44% 505 32.89% 67.11% 53.64% 2.01% 11.47%
451 36.15% 63.85% 51.49% 1.90% 10.46% 506 32.83% 67.17% 53.68% 2.01% 11.49%
452 36.08% 63.92% 51.53% 1.90% 10.49% 507 32.77% 67.23% 53.71% 2.01% 11.50%
453 36.02% 63.99% 51.58% 1.91% 10.50% 508 32.72% 67.28% 53.74% 2.02% 11.52%
454 35.94% 64.06% 51.63% 1.91% 10.52% 509 32.66% 67.34% 53.78% 2.02% 11.54%
455 35.87% 64.13% 51.68% 1.91% 10.54% 510 32.61% 67.39% 53.82% 2.02% 11.55%
456 35.81% 64.19% 51.71% 1.92% 10.56% 511 32.54% 67.46% 53.86% 2.03% 11.58%
457 35.74% 64.26% 51.75% 1.92% 10.59% 512 32.47% 67.53% 53.91% 2.03% 11.60%
198
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 513 32.41% 67.59% 53.94% 2.03% 11.61% 568 29.62% 70.38% 55.69% 2.15% 12.55%
514 32.38% 67.63% 53.97% 2.03% 11.62% 569 29.57% 70.43% 55.72% 2.15% 12.56%
515 32.31% 67.69% 54.01% 2.03% 11.64% 570 29.53% 70.47% 55.75% 2.15% 12.58%
516 32.26% 67.75% 54.04% 2.04% 11.67% 571 29.47% 70.53% 55.78% 2.15% 12.60%
517 32.20% 67.80% 54.08% 2.04% 11.69% 572 29.43% 70.57% 55.80% 2.15% 12.61%
518 32.14% 67.86% 54.11% 2.04% 11.70% 573 29.39% 70.62% 55.84% 2.16% 12.62%
519 32.08% 67.92% 54.14% 2.05% 11.74% 574 29.35% 70.65% 55.85% 2.16% 12.64%
520 32.02% 67.98% 54.18% 2.05% 11.75% 575 29.30% 70.71% 55.89% 2.16% 12.66%
521 31.97% 68.03% 54.21% 2.05% 11.77% 576 29.25% 70.75% 55.91% 2.16% 12.67%
522 31.92% 68.08% 54.25% 2.05% 11.78% 577 29.20% 70.80% 55.94% 2.17% 12.69%
523 31.87% 68.13% 54.27% 2.05% 11.80% 578 29.15% 70.85% 55.98% 2.17% 12.71%
524 31.81% 68.19% 54.31% 2.05% 11.83% 579 29.09% 70.91% 56.02% 2.17% 12.72%
525 31.77% 68.23% 54.34% 2.06% 11.84% 580 29.03% 70.97% 56.06% 2.17% 12.74%
526 31.72% 68.28% 54.37% 2.06% 11.85% 581 28.99% 71.01% 56.09% 2.17% 12.75%
527 31.66% 68.34% 54.40% 2.06% 11.88% 582 28.95% 71.06% 56.13% 2.17% 12.76%
528 31.61% 68.39% 54.43% 2.06% 11.89% 583 28.89% 71.11% 56.16% 2.17% 12.77%
529 31.57% 68.43% 54.46% 2.07% 11.91% 584 28.84% 71.16% 56.20% 2.17% 12.79%
530 31.53% 68.47% 54.48% 2.07% 11.92% 585 28.80% 71.20% 56.23% 2.18% 12.80%
531 31.48% 68.52% 54.52% 2.07% 11.93% 586 28.75% 71.25% 56.26% 2.18% 12.81%
532 31.43% 68.57% 54.55% 2.07% 11.95% 587 28.71% 71.29% 56.29% 2.18% 12.83%
533 31.36% 68.65% 54.60% 2.07% 11.97% 588 28.67% 71.33% 56.31% 2.18% 12.84%
534 31.31% 68.70% 54.63% 2.08% 11.99% 589 28.63% 71.37% 56.33% 2.18% 12.85%
535 31.24% 68.76% 54.67% 2.08% 12.01% 590 28.58% 71.42% 56.37% 2.18% 12.87%
536 31.19% 68.81% 54.70% 2.08% 12.03% 591 28.53% 71.47% 56.40% 2.19% 12.89%
537 31.14% 68.86% 54.74% 2.08% 12.04% 592 28.47% 71.53% 56.44% 2.19% 12.90%
538 31.09% 68.91% 54.77% 2.08% 12.06% 593 28.43% 71.57% 56.46% 2.19% 12.92%
539 31.04% 68.96% 54.80% 2.08% 12.08% 594 28.39% 71.61% 56.49% 2.19% 12.93%
540 31.00% 69.00% 54.83% 2.09% 12.09% 595 28.34% 71.66% 56.52% 2.20% 12.94%
541 30.94% 69.06% 54.86% 2.09% 12.11% 596 28.30% 71.70% 56.55% 2.20% 12.96%
542 30.89% 69.12% 54.90% 2.09% 12.13% 597 28.23% 71.77% 56.58% 2.20% 12.98%
543 30.83% 69.17% 54.93% 2.09% 12.15% 598 28.19% 71.81% 56.61% 2.20% 12.99%
544 30.79% 69.22% 54.96% 2.10% 12.16% 599 28.16% 71.84% 56.64% 2.20% 13.00%
545 30.73% 69.27% 55.00% 2.10% 12.17% 600 28.12% 71.88% 56.66% 2.21% 13.02%
546 30.68% 69.32% 55.03% 2.10% 12.19% 601 28.08% 71.93% 56.68% 2.21% 13.04%
547 30.63% 69.38% 55.07% 2.10% 12.21% 602 28.03% 71.97% 56.71% 2.21% 13.05%
548 30.58% 69.42% 55.09% 2.10% 12.23% 603 27.98% 72.02% 56.74% 2.21% 13.07%
549 30.54% 69.46% 55.11% 2.10% 12.24% 604 27.93% 72.07% 56.77% 2.21% 13.09%
550 30.49% 69.51% 55.14% 2.10% 12.26% 605 27.88% 72.12% 56.80% 2.21% 13.11%
551 30.44% 69.56% 55.18% 2.11% 12.28% 606 27.84% 72.16% 56.82% 2.22% 13.12%
552 30.39% 69.61% 55.21% 2.11% 12.29% 607 27.80% 72.20% 56.85% 2.22% 13.14%
553 30.33% 69.67% 55.25% 2.11% 12.31% 608 27.75% 72.25% 56.87% 2.22% 13.16%
554 30.28% 69.72% 55.28% 2.11% 12.32% 609 27.72% 72.29% 56.89% 2.22% 13.17%
555 30.23% 69.77% 55.32% 2.12% 12.34% 610 27.67% 72.33% 56.92% 2.22% 13.19%
556 30.17% 69.83% 55.35% 2.12% 12.36% 611 27.62% 72.38% 56.95% 2.23% 13.21%
557 30.14% 69.86% 55.37% 2.12% 12.37% 612 27.58% 72.43% 56.98% 2.23% 13.22%
558 30.09% 69.91% 55.39% 2.12% 12.40% 613 27.53% 72.47% 57.00% 2.23% 13.25%
559 30.04% 69.97% 55.43% 2.13% 12.41% 614 27.48% 72.52% 57.03% 2.23% 13.26%
560 30.00% 70.00% 55.45% 2.13% 12.43% 615 27.43% 72.57% 57.05% 2.23% 13.28%
561 29.94% 70.06% 55.50% 2.13% 12.44% 616 27.39% 72.62% 57.09% 2.24% 13.29%
562 29.89% 70.11% 55.52% 2.13% 12.46% 617 27.34% 72.66% 57.12% 2.24% 13.31%
563 29.85% 70.15% 55.55% 2.14% 12.47% 618 27.30% 72.70% 57.15% 2.24% 13.32%
564 29.81% 70.19% 55.57% 2.14% 12.48% 619 27.24% 72.76% 57.18% 2.24% 13.33%
565 29.76% 70.24% 55.60% 2.14% 12.50% 620 27.19% 72.81% 57.21% 2.24% 13.35%
566 29.71% 70.29% 55.63% 2.14% 12.51% 621 27.14% 72.86% 57.24% 2.25% 13.38%
567 29.67% 70.33% 55.66% 2.14% 12.53% 622 27.10% 72.91% 57.27% 2.25% 13.39%
199
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 623 27.06% 72.94% 57.29% 2.25% 13.40% 678 24.80% 75.20% 58.75% 2.33% 14.12%
624 27.03% 72.98% 57.31% 2.25% 13.41% 679 24.77% 75.23% 58.77% 2.33% 14.13%
625 26.99% 73.01% 57.33% 2.25% 13.43% 680 24.74% 75.26% 58.79% 2.34% 14.13%
626 26.94% 73.06% 57.36% 2.25% 13.44% 681 24.70% 75.31% 58.83% 2.34% 14.14%
627 26.89% 73.11% 57.40% 2.26% 13.46% 682 24.67% 75.33% 58.85% 2.34% 14.15%
628 26.85% 73.15% 57.42% 2.26% 13.47% 683 24.63% 75.37% 58.87% 2.34% 14.16%
629 26.80% 73.20% 57.45% 2.26% 13.49% 684 24.59% 75.41% 58.89% 2.34% 14.18%
630 26.75% 73.25% 57.48% 2.26% 13.51% 685 24.55% 75.45% 58.92% 2.34% 14.19%
631 26.71% 73.29% 57.51% 2.26% 13.52% 686 24.52% 75.48% 58.95% 2.34% 14.20%
632 26.66% 73.34% 57.54% 2.27% 13.53% 687 24.47% 75.53% 58.98% 2.34% 14.21%
633 26.61% 73.39% 57.58% 2.27% 13.55% 688 24.43% 75.57% 59.01% 2.34% 14.23%
634 26.57% 73.43% 57.61% 2.27% 13.56% 689 24.38% 75.62% 59.03% 2.34% 14.25%
635 26.52% 73.48% 57.63% 2.27% 13.58% 690 24.35% 75.66% 59.05% 2.34% 14.26%
636 26.49% 73.52% 57.66% 2.27% 13.58% 691 24.31% 75.69% 59.08% 2.34% 14.27%
637 26.46% 73.54% 57.67% 2.27% 13.59% 692 24.28% 75.73% 59.11% 2.34% 14.28%
638 26.43% 73.57% 57.69% 2.27% 13.61% 693 24.24% 75.77% 59.13% 2.34% 14.29%
639 26.38% 73.62% 57.72% 2.28% 13.62% 694 24.20% 75.80% 59.15% 2.35% 14.31%
640 26.34% 73.66% 57.75% 2.28% 13.63% 695 24.17% 75.83% 59.17% 2.35% 14.31%
641 26.29% 73.71% 57.78% 2.28% 13.65% 696 24.13% 75.87% 59.19% 2.35% 14.33%
642 26.25% 73.75% 57.81% 2.28% 13.66% 697 24.10% 75.91% 59.22% 2.35% 14.34%
643 26.20% 73.80% 57.84% 2.29% 13.67% 698 24.05% 75.95% 59.24% 2.35% 14.36%
644 26.18% 73.82% 57.85% 2.29% 13.68% 699 24.01% 75.99% 59.26% 2.35% 14.37%
645 26.13% 73.87% 57.89% 2.29% 13.69% 700 23.98% 76.02% 59.29% 2.36% 14.38%
646 26.09% 73.91% 57.92% 2.29% 13.70% 701 23.94% 76.06% 59.32% 2.36% 14.39%
647 26.05% 73.95% 57.94% 2.30% 13.72% 702 23.91% 76.09% 59.33% 2.36% 14.40%
648 26.01% 73.99% 57.97% 2.30% 13.73% 703 23.89% 76.11% 59.34% 2.36% 14.41%
649 25.96% 74.04% 58.00% 2.30% 13.74% 704 23.86% 76.15% 59.37% 2.36% 14.42%
650 25.92% 74.08% 58.03% 2.30% 13.75% 705 23.82% 76.18% 59.39% 2.36% 14.44%
651 25.87% 74.13% 58.07% 2.30% 13.77% 706 23.78% 76.22% 59.41% 2.36% 14.45%
652 25.83% 74.17% 58.09% 2.30% 13.78% 707 23.74% 76.26% 59.44% 2.36% 14.46%
653 25.80% 74.20% 58.11% 2.30% 13.79% 708 23.72% 76.28% 59.45% 2.36% 14.47%
654 25.76% 74.24% 58.14% 2.30% 13.81% 709 23.69% 76.31% 59.47% 2.36% 14.48%
655 25.71% 74.29% 58.18% 2.31% 13.81% 710 23.64% 76.36% 59.50% 2.36% 14.49%
656 25.67% 74.33% 58.20% 2.31% 13.83% 711 23.59% 76.41% 59.54% 2.37% 14.50%
657 25.63% 74.37% 58.23% 2.31% 13.84% 712 23.57% 76.43% 59.55% 2.37% 14.51%
658 25.59% 74.41% 58.25% 2.31% 13.85% 713 23.54% 76.46% 59.57% 2.37% 14.53%
659 25.56% 74.44% 58.27% 2.31% 13.86% 714 23.50% 76.50% 59.59% 2.37% 14.54%
660 25.52% 74.49% 58.30% 2.31% 13.88% 715 23.47% 76.54% 59.62% 2.37% 14.55%
661 25.47% 74.53% 58.33% 2.31% 13.89% 716 23.42% 76.58% 59.65% 2.38% 14.56%
662 25.44% 74.57% 58.35% 2.31% 13.91% 717 23.39% 76.61% 59.66% 2.38% 14.57%
663 25.39% 74.61% 58.38% 2.32% 13.92% 718 23.35% 76.65% 59.68% 2.38% 14.59%
664 25.36% 74.64% 58.40% 2.32% 13.93% 719 23.32% 76.68% 59.71% 2.38% 14.60%
665 25.32% 74.68% 58.42% 2.32% 13.94% 720 23.28% 76.72% 59.74% 2.38% 14.61%
666 25.29% 74.71% 58.44% 2.32% 13.95% 721 23.24% 76.76% 59.75% 2.38% 14.62%
667 25.25% 74.75% 58.47% 2.32% 13.97% 722 23.21% 76.79% 59.78% 2.38% 14.63%
668 25.20% 74.80% 58.49% 2.32% 13.99% 723 23.19% 76.81% 59.79% 2.38% 14.64%
669 25.15% 74.85% 58.53% 2.32% 14.00% 724 23.16% 76.84% 59.81% 2.38% 14.65%
670 25.12% 74.89% 58.56% 2.32% 14.00% 725 23.12% 76.88% 59.84% 2.38% 14.66%
671 25.08% 74.92% 58.58% 2.32% 14.02% 726 23.07% 76.93% 59.86% 2.39% 14.68%
672 25.03% 74.97% 58.61% 2.33% 14.04% 727 23.04% 76.96% 59.88% 2.39% 14.69%
673 24.98% 75.02% 58.64% 2.33% 14.05% 728 23.01% 76.99% 59.91% 2.39% 14.70%
674 24.94% 75.06% 58.67% 2.33% 14.07% 729 22.98% 77.02% 59.92% 2.39% 14.71%
675 24.91% 75.10% 58.69% 2.33% 14.08% 730 22.94% 77.07% 59.95% 2.39% 14.73%
676 24.87% 75.13% 58.71% 2.33% 14.09% 731 22.91% 77.09% 59.97% 2.39% 14.73%
677 24.84% 75.16% 58.72% 2.33% 14.11% 732 22.87% 77.13% 59.99% 2.39% 14.75%
200
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 733 22.84% 77.16% 60.01% 2.39% 14.76% 788 21.12% 78.88% 61.05% 2.46% 15.38%
734 22.80% 77.20% 60.03% 2.40% 14.77% 789 21.09% 78.91% 61.06% 2.46% 15.39%
735 22.77% 77.23% 60.06% 2.40% 14.78% 790 21.06% 78.94% 61.08% 2.46% 15.40%
736 22.74% 77.26% 60.08% 2.40% 14.79% 791 21.04% 78.96% 61.09% 2.46% 15.41%
737 22.70% 77.30% 60.10% 2.40% 14.80% 792 21.00% 79.00% 61.12% 2.46% 15.42%
738 22.66% 77.34% 60.12% 2.40% 14.81% 793 20.98% 79.02% 61.13% 2.46% 15.43%
739 22.63% 77.37% 60.14% 2.40% 14.83% 794 20.94% 79.06% 61.15% 2.47% 15.44%
740 22.59% 77.41% 60.16% 2.40% 14.84% 795 20.90% 79.10% 61.18% 2.47% 15.45%
741 22.56% 77.44% 60.18% 2.41% 14.85% 796 20.88% 79.12% 61.19% 2.47% 15.46%
742 22.53% 77.48% 60.20% 2.41% 14.87% 797 20.85% 79.16% 61.21% 2.47% 15.47%
743 22.49% 77.51% 60.22% 2.41% 14.88% 798 20.82% 79.18% 61.22% 2.47% 15.48%
744 22.47% 77.53% 60.23% 2.41% 14.89% 799 20.79% 79.21% 61.24% 2.47% 15.50%
745 22.43% 77.57% 60.26% 2.41% 14.90% 800 20.76% 79.24% 61.26% 2.47% 15.51%
746 22.39% 77.61% 60.28% 2.41% 14.92% 801 20.72% 79.28% 61.29% 2.47% 15.51%
747 22.36% 77.65% 60.30% 2.42% 14.93% 802 20.69% 79.31% 61.30% 2.48% 15.53%
748 22.33% 77.67% 60.32% 2.42% 14.94% 803 20.67% 79.33% 61.31% 2.48% 15.53%
749 22.30% 77.70% 60.34% 2.42% 14.95% 804 20.65% 79.35% 61.33% 2.48% 15.54%
750 22.28% 77.72% 60.35% 2.42% 14.96% 805 20.63% 79.38% 61.34% 2.48% 15.55%
751 22.24% 77.76% 60.37% 2.42% 14.97% 806 20.60% 79.40% 61.35% 2.48% 15.56%
752 22.21% 77.79% 60.40% 2.42% 14.98% 807 20.57% 79.43% 61.37% 2.49% 15.57%
753 22.17% 77.83% 60.42% 2.42% 14.99% 808 20.54% 79.46% 61.39% 2.49% 15.58%
754 22.13% 77.87% 60.45% 2.42% 15.00% 809 20.51% 79.50% 61.42% 2.49% 15.59%
755 22.11% 77.90% 60.47% 2.42% 15.01% 810 20.48% 79.52% 61.44% 2.49% 15.60%
756 22.07% 77.93% 60.49% 2.42% 15.02% 811 20.45% 79.56% 61.45% 2.49% 15.61%
757 22.04% 77.96% 60.51% 2.42% 15.03% 812 20.41% 79.59% 61.47% 2.49% 15.63%
758 22.00% 78.00% 60.52% 2.42% 15.05% 813 20.38% 79.62% 61.49% 2.49% 15.64%
759 21.98% 78.02% 60.54% 2.42% 15.06% 814 20.36% 79.65% 61.50% 2.50% 15.65%
760 21.95% 78.05% 60.55% 2.42% 15.08% 815 20.32% 79.68% 61.51% 2.50% 15.67%
761 21.92% 78.08% 60.57% 2.42% 15.09% 816 20.29% 79.71% 61.53% 2.50% 15.68%
762 21.90% 78.11% 60.58% 2.43% 15.10% 817 20.26% 79.74% 61.55% 2.50% 15.69%
763 21.87% 78.14% 60.60% 2.43% 15.11% 818 20.23% 79.77% 61.57% 2.50% 15.70%
764 21.83% 78.17% 60.61% 2.43% 15.12% 819 20.20% 79.80% 61.59% 2.50% 15.71%
765 21.81% 78.19% 60.63% 2.43% 15.13% 820 20.17% 79.83% 61.61% 2.50% 15.72%
766 21.78% 78.23% 60.66% 2.43% 15.14% 821 20.15% 79.86% 61.62% 2.50% 15.73%
767 21.74% 78.26% 60.68% 2.44% 15.15% 822 20.12% 79.88% 61.64% 2.50% 15.74%
768 21.71% 78.29% 60.69% 2.44% 15.16% 823 20.10% 79.90% 61.65% 2.50% 15.75%
769 21.68% 78.32% 60.71% 2.44% 15.17% 824 20.07% 79.93% 61.66% 2.50% 15.76%
770 21.65% 78.35% 60.73% 2.44% 15.18% 825 20.04% 79.96% 61.68% 2.51% 15.78%
771 21.62% 78.38% 60.75% 2.44% 15.20% 826 20.01% 80.00% 61.70% 2.51% 15.79%
772 21.59% 78.41% 60.76% 2.44% 15.20% 827 19.98% 80.02% 61.71% 2.51% 15.80%
773 21.55% 78.45% 60.79% 2.44% 15.22% 828 19.96% 80.04% 61.73% 2.51% 15.81%
774 21.53% 78.47% 60.80% 2.44% 15.23% 829 19.94% 80.07% 61.74% 2.51% 15.82%
775 21.50% 78.51% 60.83% 2.44% 15.23% 830 19.90% 80.10% 61.76% 2.51% 15.83%
776 21.47% 78.53% 60.84% 2.44% 15.25% 831 19.87% 80.14% 61.78% 2.51% 15.84%
777 21.44% 78.56% 60.85% 2.45% 15.26% 832 19.84% 80.16% 61.80% 2.51% 15.85%
778 21.41% 78.59% 60.87% 2.45% 15.27% 833 19.81% 80.19% 61.81% 2.51% 15.86%
779 21.37% 78.63% 60.89% 2.45% 15.29% 834 19.79% 80.21% 61.82% 2.51% 15.87%
780 21.34% 78.66% 60.91% 2.45% 15.30% 835 19.77% 80.24% 61.84% 2.51% 15.88%
781 21.33% 78.67% 60.92% 2.45% 15.30% 836 19.74% 80.26% 61.86% 2.52% 15.89%
782 21.30% 78.71% 60.94% 2.45% 15.31% 837 19.71% 80.29% 61.87% 2.52% 15.91%
783 21.27% 78.74% 60.95% 2.45% 15.33% 838 19.68% 80.32% 61.88% 2.52% 15.92%
784 21.24% 78.77% 60.97% 2.45% 15.34% 839 19.66% 80.34% 61.90% 2.52% 15.92%
785 21.21% 78.79% 60.99% 2.45% 15.35% 840 19.63% 80.37% 61.91% 2.52% 15.93%
786 21.17% 78.83% 61.02% 2.45% 15.36% 841 19.61% 80.39% 61.93% 2.52% 15.94%
787 21.14% 78.86% 61.04% 2.46% 15.37% 842 19.58% 80.42% 61.95% 2.52% 15.95%
201
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 843 19.56% 80.44% 61.96% 2.52% 15.95% 898 18.16% 81.84% 62.80% 2.58% 16.46%
844 19.54% 80.46% 61.97% 2.53% 15.96% 899 18.14% 81.87% 62.82% 2.58% 16.47%
845 19.52% 80.48% 61.99% 2.53% 15.97% 900 18.12% 81.89% 62.83% 2.58% 16.48%
846 19.49% 80.51% 62.01% 2.53% 15.98% 901 18.09% 81.91% 62.85% 2.58% 16.49%
847 19.47% 80.53% 62.02% 2.53% 15.99% 902 18.06% 81.94% 62.86% 2.58% 16.50%
848 19.43% 80.57% 62.04% 2.53% 16.00% 903 18.04% 81.96% 62.88% 2.58% 16.51%
849 19.40% 80.60% 62.06% 2.53% 16.01% 904 18.02% 81.98% 62.89% 2.58% 16.51%
850 19.38% 80.62% 62.08% 2.53% 16.02% 905 17.99% 82.01% 62.91% 2.58% 16.52%
851 19.35% 80.65% 62.09% 2.53% 16.03% 906 17.96% 82.04% 62.92% 2.58% 16.53%
852 19.33% 80.68% 62.10% 2.53% 16.04% 907 17.93% 82.07% 62.94% 2.59% 16.54%
853 19.30% 80.70% 62.12% 2.53% 16.05% 908 17.91% 82.09% 62.96% 2.59% 16.55%
854 19.28% 80.72% 62.13% 2.53% 16.06% 909 17.88% 82.12% 62.97% 2.59% 16.56%
855 19.26% 80.74% 62.15% 2.53% 16.07% 910 17.86% 82.14% 62.98% 2.59% 16.57%
856 19.23% 80.77% 62.16% 2.53% 16.08% 911 17.85% 82.15% 62.99% 2.59% 16.57%
857 19.20% 80.80% 62.17% 2.54% 16.09% 912 17.83% 82.17% 63.00% 2.59% 16.58%
858 19.18% 80.82% 62.19% 2.54% 16.10% 913 17.80% 82.20% 63.02% 2.59% 16.59%
859 19.15% 80.85% 62.20% 2.54% 16.11% 914 17.78% 82.22% 63.03% 2.60% 16.60%
860 19.12% 80.88% 62.22% 2.54% 16.13% 915 17.75% 82.25% 63.05% 2.60% 16.61%
861 19.09% 80.91% 62.23% 2.54% 16.14% 916 17.73% 82.27% 63.06% 2.60% 16.61%
862 19.07% 80.93% 62.24% 2.54% 16.14% 917 17.71% 82.29% 63.07% 2.60% 16.62%
863 19.05% 80.95% 62.26% 2.54% 16.15% 918 17.68% 82.32% 63.09% 2.60% 16.63%
864 19.02% 80.98% 62.28% 2.55% 16.16% 919 17.65% 82.35% 63.11% 2.60% 16.64%
865 19.00% 81.00% 62.29% 2.55% 16.17% 920 17.63% 82.38% 63.12% 2.60% 16.65%
866 18.98% 81.02% 62.30% 2.55% 16.18% 921 17.61% 82.39% 63.13% 2.60% 16.66%
867 18.94% 81.06% 62.33% 2.55% 16.19% 922 17.58% 82.43% 63.16% 2.60% 16.67%
868 18.91% 81.09% 62.35% 2.55% 16.19% 923 17.56% 82.44% 63.16% 2.60% 16.68%
869 18.89% 81.11% 62.36% 2.55% 16.20% 924 17.54% 82.46% 63.18% 2.60% 16.68%
870 18.86% 81.14% 62.38% 2.55% 16.21% 925 17.51% 82.49% 63.19% 2.60% 16.69%
871 18.83% 81.17% 62.40% 2.55% 16.22% 926 17.49% 82.51% 63.21% 2.60% 16.70%
872 18.81% 81.19% 62.42% 2.55% 16.22% 927 17.47% 82.54% 63.22% 2.60% 16.71%
873 18.79% 81.21% 62.43% 2.55% 16.23% 928 17.45% 82.55% 63.23% 2.60% 16.72%
874 18.77% 81.23% 62.44% 2.55% 16.24% 929 17.42% 82.58% 63.25% 2.61% 16.73%
875 18.74% 81.26% 62.46% 2.56% 16.25% 930 17.39% 82.61% 63.26% 2.61% 16.74%
876 18.71% 81.29% 62.48% 2.56% 16.25% 931 17.38% 82.62% 63.27% 2.61% 16.75%
877 18.68% 81.32% 62.50% 2.56% 16.27% 932 17.35% 82.65% 63.28% 2.61% 16.76%
878 18.67% 81.34% 62.51% 2.56% 16.27% 933 17.32% 82.68% 63.30% 2.61% 16.77%
879 18.64% 81.36% 62.53% 2.56% 16.28% 934 17.29% 82.71% 63.32% 2.61% 16.78%
880 18.62% 81.38% 62.54% 2.56% 16.29% 935 17.26% 82.74% 63.34% 2.61% 16.79%
881 18.60% 81.40% 62.54% 2.56% 16.30% 936 17.25% 82.76% 63.35% 2.61% 16.80%
882 18.58% 81.42% 62.55% 2.57% 16.31% 937 17.22% 82.78% 63.37% 2.61% 16.81%
883 18.56% 81.44% 62.56% 2.57% 16.31% 938 17.20% 82.80% 63.38% 2.61% 16.81%
884 18.54% 81.47% 62.57% 2.57% 16.33% 939 17.17% 82.83% 63.40% 2.61% 16.83%
885 18.51% 81.49% 62.59% 2.57% 16.33% 940 17.15% 82.86% 63.41% 2.61% 16.83%
886 18.49% 81.52% 62.60% 2.57% 16.35% 941 17.12% 82.88% 63.42% 2.61% 16.84%
887 18.45% 81.55% 62.62% 2.57% 16.36% 942 17.09% 82.91% 63.43% 2.62% 16.86%
888 18.43% 81.57% 62.63% 2.57% 16.37% 943 17.08% 82.92% 63.44% 2.62% 16.86%
889 18.40% 81.60% 62.65% 2.57% 16.38% 944 17.06% 82.94% 63.45% 2.62% 16.87%
890 18.38% 81.62% 62.66% 2.57% 16.39% 945 17.05% 82.95% 63.46% 2.62% 16.88%
891 18.36% 81.65% 62.68% 2.57% 16.40% 946 17.03% 82.97% 63.48% 2.62% 16.88%
892 18.33% 81.67% 62.69% 2.57% 16.41% 947 17.01% 83.00% 63.49% 2.62% 16.88%
893 18.30% 81.70% 62.71% 2.57% 16.41% 948 16.98% 83.02% 63.50% 2.62% 16.90%
894 18.28% 81.72% 62.73% 2.57% 16.42% 949 16.96% 83.04% 63.52% 2.62% 16.91%
895 18.25% 81.75% 62.75% 2.57% 16.43% 950 16.94% 83.06% 63.53% 2.62% 16.91%
896 18.23% 81.78% 62.76% 2.57% 16.44% 951 16.92% 83.09% 63.54% 2.62% 16.92%
897 18.20% 81.80% 62.78% 2.57% 16.45% 952 16.89% 83.11% 63.55% 2.62% 16.94%
202
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 953 16.86% 83.14% 63.57% 2.62% 16.95% 1008 15.76% 84.24% 64.20% 2.66% 17.38%
954 16.84% 83.16% 63.58% 2.62% 16.96% 1009 15.75% 84.26% 64.21% 2.66% 17.39%
955 16.82% 83.19% 63.60% 2.62% 16.96% 1010 15.73% 84.27% 64.22% 2.66% 17.39%
956 16.78% 83.22% 63.62% 2.62% 16.98% 1011 15.71% 84.29% 64.23% 2.66% 17.39%
957 16.76% 83.24% 63.63% 2.63% 16.99% 1012 15.69% 84.31% 64.24% 2.66% 17.40%
958 16.75% 83.26% 63.63% 2.63% 17.00% 1013 15.67% 84.33% 64.26% 2.66% 17.41%
959 16.73% 83.27% 63.64% 2.63% 17.01% 1014 15.66% 84.34% 64.27% 2.66% 17.41%
960 16.71% 83.29% 63.65% 2.63% 17.01% 1015 15.63% 84.37% 64.28% 2.66% 17.42%
961 16.69% 83.31% 63.66% 2.63% 17.02% 1016 15.62% 84.38% 64.29% 2.67% 17.43%
962 16.67% 83.33% 63.67% 2.63% 17.03% 1017 15.60% 84.40% 64.30% 2.67% 17.43%
963 16.66% 83.34% 63.68% 2.63% 17.03% 1018 15.58% 84.42% 64.32% 2.67% 17.44%
964 16.64% 83.36% 63.69% 2.63% 17.04% 1019 15.56% 84.44% 64.33% 2.67% 17.45%
965 16.61% 83.39% 63.70% 2.63% 17.05% 1020 15.55% 84.45% 64.34% 2.67% 17.45%
966 16.59% 83.41% 63.72% 2.63% 17.06% 1021 15.53% 84.47% 64.35% 2.67% 17.46%
967 16.58% 83.43% 63.73% 2.63% 17.07% 1022 15.51% 84.49% 64.36% 2.67% 17.46%
968 16.56% 83.44% 63.74% 2.63% 17.07% 1023 15.50% 84.50% 64.37% 2.67% 17.47%
969 16.53% 83.48% 63.76% 2.63% 17.08% 1024 15.48% 84.52% 64.38% 2.67% 17.47%
970 16.50% 83.50% 63.77% 2.63% 17.09% 1025 15.46% 84.54% 64.39% 2.67% 17.48%
971 16.48% 83.52% 63.79% 2.63% 17.10% 1026 15.45% 84.55% 64.40% 2.67% 17.49%
972 16.46% 83.54% 63.80% 2.64% 17.10% 1027 15.43% 84.57% 64.41% 2.67% 17.50%
973 16.44% 83.56% 63.81% 2.64% 17.12% 1028 15.41% 84.59% 64.42% 2.67% 17.50%
974 16.42% 83.59% 63.82% 2.64% 17.13% 1029 15.38% 84.62% 64.44% 2.67% 17.51%
975 16.40% 83.60% 63.83% 2.64% 17.13% 1030 15.36% 84.64% 64.45% 2.67% 17.52%
976 16.38% 83.62% 63.84% 2.64% 17.14% 1031 15.35% 84.65% 64.46% 2.67% 17.52%
977 16.37% 83.63% 63.85% 2.64% 17.15% 1032 15.33% 84.68% 64.47% 2.68% 17.53%
978 16.36% 83.65% 63.85% 2.64% 17.15% 1033 15.31% 84.69% 64.48% 2.68% 17.54%
979 16.34% 83.66% 63.87% 2.64% 17.16% 1034 15.28% 84.72% 64.50% 2.68% 17.54%
980 16.31% 83.69% 63.87% 2.64% 17.17% 1035 15.27% 84.73% 64.50% 2.68% 17.55%
981 16.30% 83.70% 63.88% 2.64% 17.18% 1036 15.25% 84.75% 64.51% 2.68% 17.56%
982 16.28% 83.72% 63.89% 2.64% 17.18% 1037 15.22% 84.78% 64.53% 2.68% 17.57%
983 16.26% 83.74% 63.90% 2.65% 17.19% 1038 15.21% 84.79% 64.54% 2.68% 17.58%
984 16.24% 83.76% 63.92% 2.65% 17.20% 1039 15.19% 84.81% 64.55% 2.68% 17.59%
985 16.22% 83.78% 63.93% 2.65% 17.21% 1040 15.18% 84.83% 64.56% 2.68% 17.59%
986 16.20% 83.81% 63.94% 2.65% 17.22% 1041 15.14% 84.86% 64.57% 2.68% 17.61%
987 16.18% 83.82% 63.95% 2.65% 17.23% 1042 15.12% 84.88% 64.59% 2.68% 17.62%
988 16.16% 83.84% 63.96% 2.65% 17.23% 1043 15.10% 84.90% 64.59% 2.68% 17.62%
989 16.14% 83.86% 63.97% 2.65% 17.24% 1044 15.09% 84.91% 64.60% 2.68% 17.63%
990 16.12% 83.88% 63.98% 2.65% 17.25% 1045 15.07% 84.93% 64.61% 2.69% 17.64%
991 16.09% 83.91% 64.00% 2.65% 17.26% 1046 15.06% 84.95% 64.62% 2.69% 17.64%
992 16.08% 83.93% 64.01% 2.65% 17.26% 1047 15.03% 84.97% 64.63% 2.69% 17.65%
993 16.06% 83.94% 64.02% 2.65% 17.27% 1048 15.01% 84.99% 64.65% 2.69% 17.65%
994 16.04% 83.96% 64.03% 2.65% 17.28% 1049 14.98% 85.02% 64.67% 2.69% 17.66%
995 16.02% 83.98% 64.04% 2.65% 17.29% 1050 14.97% 85.03% 64.68% 2.69% 17.67%
996 16.00% 84.00% 64.05% 2.65% 17.30% 1051 14.95% 85.05% 64.69% 2.69% 17.68%
997 15.99% 84.01% 64.06% 2.65% 17.30% 1052 14.93% 85.07% 64.70% 2.69% 17.68%
998 15.97% 84.03% 64.07% 2.65% 17.31% 1053 14.91% 85.09% 64.72% 2.69% 17.68%
999 15.95% 84.05% 64.08% 2.65% 17.32% 1054 14.90% 85.10% 64.73% 2.69% 17.69%
1000 15.93% 84.07% 64.09% 2.65% 17.33% 1055 14.88% 85.12% 64.74% 2.69% 17.70%
1001 15.91% 84.09% 64.11% 2.65% 17.33% 1056 14.86% 85.14% 64.74% 2.69% 17.70%
1002 15.89% 84.11% 64.12% 2.65% 17.34% 1057 14.84% 85.16% 64.75% 2.70% 17.71%
1003 15.87% 84.13% 64.13% 2.66% 17.34% 1058 14.82% 85.18% 64.76% 2.70% 17.72%
1004 15.85% 84.15% 64.15% 2.66% 17.35% 1059 14.80% 85.20% 64.77% 2.70% 17.73%
1005 15.83% 84.17% 64.16% 2.66% 17.36% 1060 14.78% 85.22% 64.78% 2.70% 17.74%
1006 15.80% 84.20% 64.17% 2.66% 17.37% 1061 14.76% 85.24% 64.80% 2.70% 17.74%
1007 15.78% 84.22% 64.19% 2.66% 17.37% 1062 14.74% 85.26% 64.81% 2.70% 17.75%
203
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 1063 14.73% 85.27% 64.82% 2.70% 17.75% 1118 13.79% 86.22% 65.36% 2.74% 18.11%
1064 14.72% 85.29% 64.82% 2.70% 17.76% 1119 13.77% 86.23% 65.37% 2.74% 18.12%
1065 14.70% 85.30% 64.83% 2.70% 17.77% 1120 13.76% 86.24% 65.38% 2.74% 18.12%
1066 14.68% 85.32% 64.84% 2.70% 17.77% 1121 13.74% 86.26% 65.39% 2.74% 18.13%
1067 14.66% 85.34% 64.85% 2.71% 17.78% 1122 13.72% 86.28% 65.41% 2.74% 18.13%
1068 14.65% 85.35% 64.86% 2.71% 17.78% 1123 13.70% 86.30% 65.42% 2.74% 18.14%
1069 14.64% 85.36% 64.87% 2.71% 17.78% 1124 13.68% 86.32% 65.43% 2.74% 18.14%
1070 14.62% 85.38% 64.88% 2.71% 17.79% 1125 13.67% 86.33% 65.44% 2.74% 18.15%
1071 14.60% 85.40% 64.89% 2.71% 17.80% 1126 13.64% 86.36% 65.45% 2.75% 18.17%
1072 14.59% 85.41% 64.90% 2.71% 17.81% 1127 13.63% 86.37% 65.45% 2.75% 18.17%
1073 14.56% 85.44% 64.91% 2.71% 17.81% 1128 13.62% 86.38% 65.46% 2.75% 18.18%
1074 14.55% 85.45% 64.92% 2.71% 17.82% 1129 13.60% 86.40% 65.47% 2.75% 18.18%
1075 14.53% 85.47% 64.93% 2.71% 17.83% 1130 13.59% 86.41% 65.48% 2.75% 18.19%
1076 14.51% 85.49% 64.94% 2.71% 17.84% 1131 13.57% 86.43% 65.49% 2.75% 18.19%
1077 14.49% 85.52% 64.95% 2.72% 17.85% 1132 13.56% 86.44% 65.50% 2.75% 18.20%
1078 14.46% 85.54% 64.97% 2.72% 17.85% 1133 13.54% 86.46% 65.51% 2.75% 18.21%
1079 14.45% 85.55% 64.97% 2.72% 17.86% 1134 13.52% 86.48% 65.51% 2.75% 18.22%
1080 14.42% 85.58% 64.99% 2.72% 17.87% 1135 13.50% 86.50% 65.53% 2.75% 18.22%
1081 14.41% 85.59% 65.00% 2.72% 17.88% 1136 13.49% 86.52% 65.54% 2.75% 18.23%
1082 14.39% 85.61% 65.01% 2.72% 17.89% 1137 13.48% 86.53% 65.54% 2.75% 18.23%
1083 14.38% 85.63% 65.01% 2.72% 17.89% 1138 13.46% 86.54% 65.55% 2.75% 18.24%
1084 14.36% 85.64% 65.02% 2.72% 17.90% 1139 13.45% 86.56% 65.56% 2.75% 18.25%
1085 14.34% 85.66% 65.03% 2.72% 17.91% 1140 13.43% 86.57% 65.57% 2.75% 18.25%
1086 14.32% 85.68% 65.04% 2.72% 17.92% 1141 13.41% 86.59% 65.58% 2.75% 18.26%
1087 14.30% 85.70% 65.05% 2.72% 17.92% 1142 13.39% 86.61% 65.59% 2.75% 18.26%
1088 14.28% 85.72% 65.07% 2.72% 17.93% 1143 13.38% 86.62% 65.60% 2.75% 18.27%
1089 14.27% 85.73% 65.08% 2.72% 17.93% 1144 13.36% 86.64% 65.62% 2.75% 18.28%
1090 14.25% 85.75% 65.09% 2.72% 17.94% 1145 13.34% 86.66% 65.62% 2.76% 18.28%
1091 14.24% 85.76% 65.09% 2.73% 17.95% 1146 13.32% 86.68% 65.64% 2.76% 18.29%
1092 14.22% 85.78% 65.10% 2.73% 17.95% 1147 13.31% 86.69% 65.64% 2.76% 18.29%
1093 14.21% 85.79% 65.11% 2.73% 17.96% 1148 13.29% 86.71% 65.65% 2.76% 18.30%
1094 14.19% 85.81% 65.12% 2.73% 17.96% 1149 13.27% 86.73% 65.66% 2.76% 18.31%
1095 14.17% 85.83% 65.13% 2.73% 17.97% 1150 13.26% 86.74% 65.66% 2.76% 18.32%
1096 14.16% 85.84% 65.14% 2.73% 17.97% 1151 13.25% 86.75% 65.67% 2.76% 18.32%
1097 14.15% 85.85% 65.14% 2.73% 17.98% 1152 13.24% 86.76% 65.68% 2.76% 18.33%
1098 14.13% 85.87% 65.15% 2.73% 17.99% 1153 13.22% 86.78% 65.69% 2.76% 18.34%
1099 14.11% 85.89% 65.16% 2.73% 17.99% 1154 13.21% 86.79% 65.69% 2.76% 18.34%
1100 14.10% 85.90% 65.17% 2.73% 18.00% 1155 13.20% 86.80% 65.70% 2.76% 18.35%
1101 14.08% 85.92% 65.18% 2.73% 18.00% 1156 13.19% 86.81% 65.70% 2.76% 18.35%
1102 14.07% 85.93% 65.19% 2.73% 18.01% 1157 13.17% 86.83% 65.71% 2.76% 18.36%
1103 14.05% 85.95% 65.20% 2.74% 18.01% 1158 13.15% 86.85% 65.72% 2.76% 18.37%
1104 14.03% 85.97% 65.21% 2.74% 18.02% 1159 13.14% 86.86% 65.73% 2.76% 18.37%
1105 14.01% 85.99% 65.22% 2.74% 18.03% 1160 13.13% 86.88% 65.74% 2.76% 18.38%
1106 13.99% 86.01% 65.23% 2.74% 18.04% 1161 13.11% 86.89% 65.74% 2.76% 18.39%
1107 13.98% 86.02% 65.24% 2.74% 18.04% 1162 13.10% 86.90% 65.75% 2.76% 18.39%
1108 13.96% 86.04% 65.26% 2.74% 18.05% 1163 13.09% 86.91% 65.76% 2.76% 18.39%
1109 13.94% 86.06% 65.27% 2.74% 18.06% 1164 13.07% 86.93% 65.76% 2.77% 18.40%
1110 13.92% 86.08% 65.28% 2.74% 18.06% 1165 13.06% 86.94% 65.77% 2.77% 18.40%
1111 13.90% 86.10% 65.29% 2.74% 18.07% 1166 13.05% 86.95% 65.78% 2.77% 18.41%
1112 13.89% 86.11% 65.30% 2.74% 18.08% 1167 13.03% 86.97% 65.79% 2.77% 18.41%
1113 13.87% 86.13% 65.31% 2.74% 18.08% 1168 13.01% 86.99% 65.80% 2.77% 18.42%
1114 13.86% 86.14% 65.31% 2.74% 18.09% 1169 13.01% 86.99% 65.80% 2.77% 18.42%
1115 13.84% 86.16% 65.33% 2.74% 18.09% 1170 13.00% 87.00% 65.81% 2.77% 18.42%
1116 13.82% 86.18% 65.34% 2.74% 18.10% 1171 12.98% 87.02% 65.81% 2.77% 18.43%
1117 13.80% 86.20% 65.35% 2.74% 18.10% 1172 12.97% 87.03% 65.82% 2.77% 18.44%
204
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 1173 12.95% 87.05% 65.83% 2.77% 18.45%
1174 12.94% 87.06% 65.83% 2.77% 18.46%
1175 12.93% 87.07% 65.84% 2.77% 18.46%
1176 12.92% 87.08% 65.85% 2.77% 18.46%
1177 12.91% 87.09% 65.86% 2.77% 18.47%
1178 12.90% 87.11% 65.86% 2.77% 18.47%
1179 12.88% 87.12% 65.87% 2.77% 18.48%
1180 12.87% 87.13% 65.87% 2.77% 18.48%
1181 12.85% 87.15% 65.89% 2.77% 18.49%
1182 12.84% 87.16% 65.89% 2.77% 18.50%
1183 12.81% 87.19% 65.91% 2.77% 18.51%
1184 12.80% 87.20% 65.92% 2.78% 18.51%
1185 12.79% 87.21% 65.93% 2.78% 18.51%
1186 12.77% 87.23% 65.94% 2.78% 18.52%
1187 12.76% 87.24% 65.94% 2.78% 18.53%
1188 12.74% 87.26% 65.95% 2.78% 18.53%
1189 12.72% 87.28% 65.96% 2.78% 18.54%
1190 12.71% 87.29% 65.97% 2.78% 18.54%
1191 12.70% 87.30% 65.98% 2.78% 18.54%
1192 12.69% 87.32% 65.99% 2.78% 18.55%
1193 12.66% 87.34% 66.00% 2.78% 18.56%
1194 12.64% 87.36% 66.01% 2.78% 18.57%
1195 12.62% 87.38% 66.02% 2.79% 18.57%
1196 12.60% 87.40% 66.04% 2.79% 18.58%
1197 12.59% 87.42% 66.04% 2.79% 18.59%
1198 12.57% 87.44% 66.05% 2.79% 18.60%
1199 12.55% 87.46% 66.06% 2.79% 18.60%
1200 12.53% 87.47% 66.07% 2.79% 18.61%
205
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA
-306 98.34% 1.66% 0.43% 1.23% 0.00%
-305 98.33% 1.67% 0.43% 1.24% 0.00%
Table B6. LOCA Probability History for ASP-05 -304 98.32% 1.68% 0.44% 1.24% 0.00%
for Days After TOD -303 98.31% 1.69% 0.45% 1.25% 0.00%
-302 98.30% 1.70% 0.45% 1.25% 0.00%
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA -301 98.29% 1.71% 0.45% 1.25% 0.00%
-365 98.86% 1.14% 0.25% 0.90% 0.00% -300 98.29% 1.71% 0.46% 1.26% 0.00%
-364 98.85% 1.15% 0.25% 0.90% 0.00% -299 98.27% 1.73% 0.46% 1.26% 0.00%
-363 98.84% 1.16% 0.25% 0.91% 0.00% -298 98.26% 1.74% 0.47% 1.27% 0.00%
-362 98.84% 1.16% 0.25% 0.91% 0.00% -297 98.25% 1.75% 0.47% 1.28% 0.00%
-361 98.83% 1.17% 0.25% 0.91% 0.00% -296 98.24% 1.76% 0.47% 1.29% 0.00%
-360 98.82% 1.18% 0.26% 0.92% 0.00% -295 98.23% 1.77% 0.48% 1.30% 0.00%
-359 98.81% 1.19% 0.26% 0.93% 0.00% -294 98.21% 1.79% 0.48% 1.31% 0.00%
-358 98.80% 1.20% 0.26% 0.93% 0.00% -293 98.20% 1.80% 0.49% 1.32% 0.00%
-357 98.80% 1.20% 0.27% 0.94% 0.00% -292 98.18% 1.82% 0.49% 1.33% 0.00%
-356 98.79% 1.21% 0.27% 0.94% 0.00% -291 98.17% 1.83% 0.50% 1.34% 0.00%
-355 98.78% 1.22% 0.27% 0.95% 0.00% -290 98.16% 1.84% 0.50% 1.34% 0.00%
-354 98.77% 1.23% 0.27% 0.96% 0.00% -289 98.14% 1.86% 0.51% 1.35% 0.00%
-353 98.76% 1.24% 0.28% 0.96% 0.00% -288 98.13% 1.87% 0.51% 1.36% 0.00%
-352 98.76% 1.24% 0.28% 0.96% 0.00% -287 98.12% 1.88% 0.52% 1.37% 0.00%
-351 98.75% 1.25% 0.29% 0.96% 0.00% -286 98.10% 1.90% 0.52% 1.38% 0.00%
-350 98.75% 1.25% 0.29% 0.97% 0.00% -285 98.09% 1.92% 0.52% 1.39% 0.00%
-349 98.74% 1.26% 0.29% 0.97% 0.00% -284 98.07% 1.93% 0.53% 1.40% 0.00%
-348 98.73% 1.27% 0.30% 0.97% 0.00% -283 98.06% 1.94% 0.53% 1.41% 0.00%
-347 98.72% 1.28% 0.30% 0.97% 0.00% -282 98.05% 1.95% 0.54% 1.41% 0.00%
-346 98.72% 1.28% 0.31% 0.98% 0.00% -281 98.04% 1.96% 0.54% 1.42% 0.00%
-345 98.71% 1.29% 0.31% 0.98% 0.00% -280 98.03% 1.97% 0.55% 1.42% 0.00%
-344 98.70% 1.30% 0.31% 0.99% 0.00% -279 98.01% 1.99% 0.55% 1.44% 0.00%
-343 98.69% 1.31% 0.32% 0.99% 0.00% -278 98.00% 2.00% 0.56% 1.44% 0.00%
-342 98.69% 1.31% 0.32% 0.99% 0.00% -277 97.99% 2.02% 0.57% 1.45% 0.00%
-341 98.68% 1.32% 0.32% 1.01% 0.00% -276 97.97% 2.03% 0.57% 1.46% 0.00%
-340 98.67% 1.33% 0.32% 1.01% 0.00% -275 97.95% 2.05% 0.58% 1.47% 0.00%
-339 98.66% 1.34% 0.32% 1.01% 0.00% -274 97.94% 2.06% 0.58% 1.49% 0.00%
-338 98.65% 1.35% 0.33% 1.02% 0.00% -273 97.93% 2.08% 0.58% 1.50% 0.00%
-337 98.64% 1.36% 0.33% 1.03% 0.00% -272 97.91% 2.09% 0.58% 1.51% 0.00%
-336 98.63% 1.37% 0.33% 1.04% 0.00% -271 97.90% 2.10% 0.59% 1.52% 0.00%
-335 98.62% 1.38% 0.33% 1.04% 0.00% -270 97.87% 2.13% 0.60% 1.53% 0.00%
-334 98.62% 1.38% 0.34% 1.05% 0.00% -269 97.86% 2.14% 0.61% 1.54% 0.00%
-333 98.61% 1.39% 0.34% 1.05% 0.00% -268 97.84% 2.16% 0.61% 1.55% 0.00%
-332 98.60% 1.40% 0.34% 1.06% 0.00% -267 97.82% 2.18% 0.62% 1.56% 0.00%
-331 98.59% 1.41% 0.34% 1.06% 0.00% -266 97.81% 2.19% 0.62% 1.57% 0.00%
-330 98.59% 1.42% 0.35% 1.07% 0.00% -265 97.80% 2.20% 0.63% 1.58% 0.00%
-329 98.57% 1.43% 0.35% 1.08% 0.00% -264 97.79% 2.21% 0.63% 1.58% 0.00%
-328 98.57% 1.43% 0.35% 1.08% 0.00% -263 97.77% 2.23% 0.64% 1.59% 0.00%
-327 98.56% 1.44% 0.36% 1.08% 0.00% -262 97.75% 2.25% 0.64% 1.60% 0.00%
-326 98.55% 1.45% 0.36% 1.09% 0.00% -261 97.74% 2.26% 0.65% 1.61% 0.00%
-325 98.54% 1.46% 0.37% 1.09% 0.00% -260 97.73% 2.27% 0.65% 1.62% 0.00%
-324 98.53% 1.47% 0.37% 1.10% 0.00% -259 97.72% 2.28% 0.66% 1.63% 0.00%
-323 98.52% 1.48% 0.38% 1.11% 0.00% -258 97.71% 2.30% 0.66% 1.63% 0.00%
-322 98.50% 1.50% 0.38% 1.12% 0.00% -257 97.69% 2.31% 0.67% 1.64% 0.00%
-321 98.49% 1.51% 0.39% 1.12% 0.00% -256 97.67% 2.33% 0.68% 1.65% 0.00%
-320 98.48% 1.52% 0.39% 1.13% 0.00% -255 97.66% 2.34% 0.68% 1.66% 0.00%
-319 98.47% 1.53% 0.39% 1.14% 0.00% -254 97.64% 2.36% 0.69% 1.67% 0.00%
-318 98.45% 1.55% 0.40% 1.15% 0.00% -253 97.63% 2.38% 0.70% 1.68% 0.00%
-317 98.45% 1.55% 0.40% 1.15% 0.00% -252 97.61% 2.39% 0.71% 1.68% 0.00%
-316 98.44% 1.56% 0.40% 1.16% 0.00% -251 97.59% 2.41% 0.71% 1.70% 0.00%
-315 98.43% 1.57% 0.40% 1.17% 0.00% -250 97.57% 2.43% 0.72% 1.71% 0.00%
-314 98.42% 1.58% 0.41% 1.17% 0.00% -249 97.56% 2.44% 0.72% 1.72% 0.00%
-313 98.41% 1.59% 0.41% 1.18% 0.00% -248 97.55% 2.45% 0.73% 1.72% 0.00%
-312 98.40% 1.60% 0.41% 1.19% 0.00% -247 97.54% 2.46% 0.73% 1.73% 0.00%
-311 98.39% 1.61% 0.41% 1.19% 0.00% -246 97.52% 2.48% 0.74% 1.74% 0.00%
-310 98.38% 1.62% 0.42% 1.20% 0.00% -245 97.50% 2.50% 0.75% 1.75% 0.00%
-309 98.37% 1.63% 0.42% 1.21% 0.00% -244 97.49% 2.51% 0.76% 1.75% 0.00%
-308 98.36% 1.65% 0.43% 1.22% 0.00% -243 97.47% 2.53% 0.77% 1.76% 0.00%
-307 98.35% 1.65% 0.43% 1.23% 0.00% -242 97.46% 2.54% 0.77% 1.77% 0.00%
206
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA
-241 97.44% 2.56% 0.78% 1.78% 0.00% -176 95.89% 4.11% 1.44% 2.67% 0.00%
-240 97.43% 2.57% 0.78% 1.79% 0.00% -175 95.86% 4.14% 1.45% 2.70% 0.00%
-239 97.41% 2.59% 0.79% 1.80% 0.00% -174 95.82% 4.18% 1.47% 2.72% 0.00%
-238 97.40% 2.60% 0.79% 1.81% 0.00% -173 95.79% 4.22% 1.49% 2.73% 0.00%
-237 97.38% 2.62% 0.80% 1.83% 0.00% -172 95.75% 4.25% 1.50% 2.75% 0.00%
-236 97.35% 2.65% 0.81% 1.84% 0.00% -171 95.71% 4.29% 1.52% 2.77% 0.00%
-235 97.34% 2.66% 0.81% 1.85% 0.00% -170 95.68% 4.32% 1.53% 2.79% 0.00%
-234 97.32% 2.69% 0.82% 1.87% 0.00% -169 95.65% 4.35% 1.55% 2.80% 0.00%
-233 97.29% 2.71% 0.83% 1.88% 0.00% -168 95.62% 4.38% 1.56% 2.82% 0.00%
-232 97.26% 2.74% 0.84% 1.90% 0.00% -167 95.58% 4.43% 1.58% 2.85% 0.00%
-231 97.25% 2.76% 0.85% 1.91% 0.00% -166 95.55% 4.45% 1.59% 2.86% 0.00%
-230 97.23% 2.77% 0.85% 1.92% 0.00% -165 95.51% 4.49% 1.61% 2.88% 0.00%
-229 97.21% 2.79% 0.86% 1.93% 0.00% -164 95.48% 4.52% 1.63% 2.90% 0.00%
-228 97.19% 2.81% 0.87% 1.94% 0.00% -163 95.45% 4.55% 1.64% 2.91% 0.00%
-227 97.17% 2.83% 0.88% 1.95% 0.00% -162 95.41% 4.59% 1.66% 2.93% 0.00%
-226 97.15% 2.85% 0.89% 1.96% 0.00% -161 95.39% 4.61% 1.67% 2.94% 0.00%
-225 97.13% 2.87% 0.90% 1.97% 0.00% -160 95.35% 4.65% 1.68% 2.96% 0.00%
-224 97.11% 2.90% 0.91% 1.99% 0.00% -159 95.32% 4.68% 1.70% 2.98% 0.00%
-223 97.09% 2.91% 0.91% 2.00% 0.00% -158 95.29% 4.71% 1.72% 3.00% 0.00%
-222 97.07% 2.93% 0.92% 2.02% 0.00% -157 95.25% 4.75% 1.74% 3.01% 0.00%
-221 97.05% 2.96% 0.93% 2.02% 0.00% -156 95.22% 4.78% 1.75% 3.03% 0.00%
-220 97.02% 2.98% 0.94% 2.04% 0.00% -155 95.20% 4.80% 1.76% 3.04% 0.00%
-219 97.00% 3.00% 0.95% 2.05% 0.00% -154 95.17% 4.83% 1.77% 3.06% 0.00%
-218 96.98% 3.02% 0.96% 2.06% 0.00% -153 95.14% 4.86% 1.79% 3.08% 0.00%
-217 96.95% 3.05% 0.97% 2.08% 0.00% -152 95.11% 4.90% 1.80% 3.09% 0.00%
-216 96.92% 3.08% 0.98% 2.10% 0.00% -151 95.06% 4.94% 1.82% 3.12% 0.00%
-215 96.90% 3.11% 0.99% 2.11% 0.00% -150 95.04% 4.97% 1.82% 3.14% 0.00%
-214 96.87% 3.13% 1.01% 2.12% 0.00% -149 95.00% 5.00% 1.84% 3.16% 0.00%
-213 96.85% 3.15% 1.01% 2.13% 0.00% -148 94.97% 5.03% 1.86% 3.17% 0.00%
-212 96.82% 3.18% 1.03% 2.14% 0.00% -147 94.93% 5.07% 1.88% 3.19% 0.00%
-211 96.81% 3.19% 1.04% 2.15% 0.00% -146 94.90% 5.10% 1.89% 3.21% 0.00%
-210 96.78% 3.22% 1.05% 2.17% 0.00% -145 94.87% 5.13% 1.91% 3.22% 0.00%
-209 96.76% 3.24% 1.06% 2.18% 0.00% -144 94.83% 5.17% 1.94% 3.23% 0.00%
-208 96.74% 3.26% 1.07% 2.19% 0.00% -143 94.80% 5.20% 1.95% 3.25% 0.00%
-207 96.72% 3.28% 1.08% 2.21% 0.00% -142 94.76% 5.24% 1.97% 3.28% 0.00%
-206 96.69% 3.31% 1.09% 2.22% 0.00% -141 94.72% 5.28% 1.99% 3.29% 0.00%
-205 96.67% 3.33% 1.10% 2.23% 0.00% -140 94.69% 5.31% 2.00% 3.31% 0.00%
-204 96.65% 3.35% 1.11% 2.24% 0.00% -139 94.65% 5.35% 2.02% 3.33% 0.00%
-203 96.62% 3.39% 1.12% 2.26% 0.00% -138 94.60% 5.41% 2.05% 3.36% 0.00%
-202 96.59% 3.41% 1.14% 2.27% 0.00% -137 94.56% 5.44% 2.07% 3.38% 0.00%
-201 96.57% 3.43% 1.15% 2.29% 0.00% -136 94.52% 5.48% 2.08% 3.40% 0.00%
-200 96.55% 3.45% 1.15% 2.30% 0.00% -135 94.47% 5.53% 2.10% 3.43% 0.00%
-199 96.52% 3.48% 1.16% 2.32% 0.00% -134 94.44% 5.56% 2.12% 3.45% 0.00%
-198 96.49% 3.51% 1.18% 2.33% 0.00% -133 94.39% 5.61% 2.13% 3.48% 0.00%
-197 96.46% 3.54% 1.19% 2.35% 0.00% -132 94.35% 5.65% 2.16% 3.49% 0.00%
-196 96.43% 3.57% 1.21% 2.36% 0.00% -131 94.31% 5.69% 2.17% 3.52% 0.00%
-195 96.40% 3.60% 1.22% 2.38% 0.00% -130 94.28% 5.72% 2.18% 3.54% 0.00%
-194 96.38% 3.62% 1.23% 2.39% 0.00% -129 94.24% 5.77% 2.21% 3.56% 0.00%
-193 96.36% 3.65% 1.24% 2.41% 0.00% -128 94.20% 5.81% 2.23% 3.58% 0.00%
-192 96.33% 3.67% 1.25% 2.42% 0.00% -127 94.15% 5.85% 2.25% 3.60% 0.00%
-191 96.31% 3.69% 1.26% 2.44% 0.00% -126 94.10% 5.90% 2.28% 3.62% 0.00%
-190 96.28% 3.72% 1.27% 2.45% 0.00% -125 94.06% 5.94% 2.30% 3.64% 0.00%
-189 96.26% 3.74% 1.28% 2.46% 0.00% -124 94.02% 5.98% 2.31% 3.67% 0.00%
-188 96.22% 3.78% 1.30% 2.48% 0.00% -123 93.96% 6.04% 2.35% 3.69% 0.00%
-187 96.20% 3.80% 1.30% 2.50% 0.00% -122 93.94% 6.07% 2.36% 3.71% 0.00%
-186 96.17% 3.83% 1.32% 2.52% 0.00% -121 93.88% 6.12% 2.38% 3.74% 0.00%
-185 96.14% 3.86% 1.33% 2.53% 0.00% -120 93.84% 6.16% 2.40% 3.77% 0.00%
-184 96.12% 3.88% 1.33% 2.55% 0.00% -119 93.79% 6.21% 2.42% 3.79% 0.00%
-183 96.09% 3.91% 1.34% 2.56% 0.00% -118 93.74% 6.26% 2.44% 3.82% 0.00%
-182 96.07% 3.94% 1.35% 2.58% 0.00% -117 93.71% 6.30% 2.46% 3.83% 0.00%
-181 96.04% 3.97% 1.37% 2.60% 0.00% -116 93.65% 6.35% 2.49% 3.86% 0.00%
-180 96.01% 3.99% 1.38% 2.62% 0.00% -115 93.61% 6.39% 2.50% 3.89% 0.00%
-179 95.98% 4.02% 1.39% 2.63% 0.00% -114 93.57% 6.43% 2.53% 3.91% 0.00%
-178 95.95% 4.05% 1.41% 2.64% 0.00% -113 93.52% 6.48% 2.55% 3.93% 0.00%
-177 95.92% 4.08% 1.42% 2.66% 0.00% -112 93.48% 6.52% 2.57% 3.95% 0.00%
207
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA
-111 93.43% 6.57% 2.59% 3.98% 0.00% -46 89.73% 10.28% 4.41% 5.86% 0.00%
-110 93.40% 6.60% 2.61% 4.00% 0.00% -45 89.67% 10.34% 4.44% 5.89% 0.00%
-109 93.36% 6.65% 2.63% 4.02% 0.00% -44 89.60% 10.40% 4.47% 5.93% 0.00%
-108 93.31% 6.69% 2.65% 4.04% 0.00% -43 89.52% 10.48% 4.51% 5.97% 0.00%
-107 93.27% 6.73% 2.67% 4.06% 0.00% -42 89.45% 10.55% 4.54% 6.01% 0.00%
-106 93.21% 6.79% 2.69% 4.10% 0.00% -41 89.38% 10.62% 4.57% 6.05% 0.00%
-105 93.16% 6.84% 2.72% 4.12% 0.00% -40 89.31% 10.70% 4.60% 6.09% 0.00%
-104 93.12% 6.88% 2.73% 4.14% 0.00% -39 89.23% 10.77% 4.64% 6.12% 0.00%
-103 93.07% 6.93% 2.76% 4.17% 0.00% -38 89.16% 10.84% 4.68% 6.16% 0.00%
-102 93.03% 6.97% 2.78% 4.19% 0.00% -37 89.09% 10.91% 4.72% 6.19% 0.00%
-101 92.99% 7.01% 2.80% 4.22% 0.00% -36 89.02% 10.99% 4.76% 6.22% 0.00%
-100 92.94% 7.06% 2.82% 4.24% 0.00% -35 88.95% 11.05% 4.80% 6.26% 0.00%
-99 92.89% 7.11% 2.85% 4.27% 0.00% -34 88.88% 11.12% 4.83% 6.29% 0.00%
-98 92.85% 7.15% 2.86% 4.29% 0.00% -33 88.80% 11.20% 4.87% 6.33% 0.00%
-97 92.80% 7.20% 2.88% 4.31% 0.00% -32 88.72% 11.28% 4.91% 6.37% 0.00%
-96 92.74% 7.26% 2.92% 4.34% 0.00% -31 88.64% 11.36% 4.95% 6.41% 0.00%
-95 92.69% 7.31% 2.94% 4.37% 0.00% -30 88.56% 11.44% 4.99% 6.45% 0.00%
-94 92.63% 7.37% 2.97% 4.40% 0.00% -29 88.48% 11.52% 5.02% 6.50% 0.00%
-93 92.57% 7.43% 3.00% 4.43% 0.00% -28 88.40% 11.60% 5.07% 6.53% 0.00%
-92 92.51% 7.49% 3.03% 4.46% 0.00% -27 88.33% 11.67% 5.10% 6.57% 0.00%
-91 92.45% 7.55% 3.07% 4.48% 0.00% -26 88.25% 11.75% 5.15% 6.60% 0.00%
-90 92.39% 7.61% 3.10% 4.52% 0.00% -25 88.17% 11.83% 5.19% 6.64% 0.00%
-89 92.34% 7.67% 3.12% 4.54% 0.00% -24 88.10% 11.91% 5.23% 6.68% 0.00%
-88 92.28% 7.72% 3.15% 4.58% 0.00% -23 88.02% 11.98% 5.26% 6.72% 0.00%
-87 92.23% 7.78% 3.18% 4.60% 0.00% -22 87.95% 12.05% 5.29% 6.76% 0.00%
-86 92.17% 7.83% 3.20% 4.63% 0.00% -21 87.87% 12.13% 5.33% 6.80% 0.00%
-85 92.10% 7.90% 3.24% 4.66% 0.00% -20 87.79% 12.21% 5.37% 6.83% 0.00%
-84 92.06% 7.94% 3.26% 4.68% 0.00% -19 87.72% 12.28% 5.41% 6.87% 0.00%
-83 91.99% 8.01% 3.30% 4.72% 0.00% -18 87.65% 12.36% 5.45% 6.91% 0.00%
-82 91.94% 8.06% 3.32% 4.74% 0.00% -17 87.55% 12.45% 5.49% 6.95% 0.00%
-81 91.88% 8.12% 3.35% 4.77% 0.00% -16 87.47% 12.53% 5.53% 7.00% 0.00%
-80 91.82% 8.18% 3.37% 4.81% 0.00% -15 87.40% 12.60% 5.57% 7.03% 0.00%
-79 91.78% 8.22% 3.40% 4.83% 0.00% -14 87.32% 12.68% 5.61% 7.07% 0.00%
-78 91.73% 8.27% 3.42% 4.85% 0.00% -13 87.24% 12.76% 5.65% 7.11% 0.00%
-77 91.68% 8.32% 3.44% 4.88% 0.00% -12 87.15% 12.85% 5.71% 7.14% 0.00%
-76 91.62% 8.38% 3.47% 4.91% 0.00% -11 87.08% 12.92% 5.74% 7.18% 0.00%
-75 91.56% 8.44% 3.50% 4.94% 0.00% -10 86.99% 13.01% 5.78% 7.22% 0.00%
-74 91.49% 8.51% 3.54% 4.97% 0.00% -9 86.91% 13.09% 5.82% 7.27% 0.00%
-73 91.43% 8.57% 3.57% 5.00% 0.00% -8 86.83% 13.17% 5.86% 7.31% 0.00%
-72 91.37% 8.63% 3.60% 5.03% 0.00% -7 86.75% 13.25% 5.90% 7.35% 0.00%
-71 91.31% 8.69% 3.64% 5.06% 0.00% -6 86.66% 13.34% 5.94% 7.41% 0.00%
-70 91.25% 8.75% 3.66% 5.09% 0.00% -5 86.56% 13.44% 5.98% 7.46% 0.00%
-69 91.20% 8.80% 3.69% 5.11% 0.00% -4 86.48% 13.53% 6.01% 7.51% 0.00%
-68 91.15% 8.85% 3.71% 5.14% 0.00% -3 86.40% 13.60% 6.05% 7.55% 0.00%
-67 91.08% 8.92% 3.75% 5.17% 0.00% -2 86.29% 13.71% 6.10% 7.60% 0.00%
-66 91.02% 8.98% 3.77% 5.21% 0.00% -1 86.21% 13.79% 6.15% 7.64% 0.00%
-65 90.96% 9.04% 3.80% 5.24% 0.00% 0 86.07% 13.93% 6.19% 7.73% 0.00%
-64 90.91% 9.09% 3.82% 5.27% 0.00% 1 85.99% 14.01% 6.24% 7.77% 0.00%
-63 90.85% 9.15% 3.85% 5.30% 0.00% 2 85.89% 14.11% 6.28% 7.82% 0.00%
-62 90.79% 9.22% 3.88% 5.34% 0.00% 3 85.80% 14.20% 6.33% 7.87% 0.00%
-61 90.72% 9.28% 3.91% 5.37% 0.00% 4 85.72% 14.28% 6.37% 7.91% 0.00%
-60 90.64% 9.36% 3.95% 5.40% 0.00% 5 85.63% 14.38% 6.41% 7.96% 0.00%
-59 90.58% 9.42% 3.99% 5.44% 0.00% 6 85.54% 14.46% 6.45% 8.01% 0.00%
-58 90.50% 9.50% 4.02% 5.48% 0.00% 7 85.45% 14.55% 6.50% 8.05% 0.00%
-57 90.43% 9.57% 4.05% 5.52% 0.00% 8 85.36% 14.64% 6.54% 8.10% 0.01%
-56 90.37% 9.63% 4.08% 5.55% 0.00% 9 85.28% 14.73% 6.59% 8.14% 0.01%
-55 90.30% 9.70% 4.12% 5.58% 0.00% 10 85.19% 14.81% 6.63% 8.17% 0.01%
-54 90.25% 9.75% 4.15% 5.60% 0.00% 11 85.09% 14.91% 6.69% 8.22% 0.01%
-53 90.19% 9.81% 4.18% 5.63% 0.00% 12 85.00% 15.00% 6.73% 8.27% 0.01%
-52 90.13% 9.87% 4.21% 5.66% 0.00% 13 84.93% 15.07% 6.75% 8.32% 0.01%
-51 90.05% 9.95% 4.25% 5.70% 0.00% 14 84.85% 15.15% 6.80% 8.35% 0.01%
-50 89.99% 10.01% 4.28% 5.73% 0.00% 15 84.74% 15.26% 6.85% 8.39% 0.01%
-49 89.93% 10.07% 4.30% 5.77% 0.00% 16 84.65% 15.35% 6.90% 8.44% 0.01%
-48 89.86% 10.14% 4.34% 5.80% 0.00% 17 84.57% 15.43% 6.93% 8.49% 0.01%
-47 89.79% 10.21% 4.38% 5.83% 0.00% 18 84.48% 15.52% 6.97% 8.54% 0.01%
208
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 19 84.37% 15.63% 7.03% 8.58% 0.01% 84 77.42% 22.58% 10.27% 12.26% 0.05%
20 84.27% 15.73% 7.08% 8.64% 0.01% 85 77.30% 22.70% 10.33% 12.32% 0.05%
21 84.15% 15.85% 7.15% 8.69% 0.01% 86 77.18% 22.82% 10.38% 12.39% 0.05%
22 84.06% 15.94% 7.18% 8.75% 0.01% 87 77.08% 22.92% 10.43% 12.43% 0.05%
23 83.95% 16.05% 7.22% 8.82% 0.01% 88 76.96% 23.04% 10.47% 12.51% 0.05%
24 83.85% 16.15% 7.27% 8.86% 0.02% 89 76.85% 23.15% 10.52% 12.57% 0.06%
25 83.74% 16.26% 7.32% 8.92% 0.02% 90 76.74% 23.26% 10.56% 12.64% 0.06%
26 83.65% 16.35% 7.36% 8.97% 0.02% 91 76.62% 23.38% 10.62% 12.70% 0.06%
27 83.55% 16.45% 7.42% 9.01% 0.02% 92 76.51% 23.49% 10.67% 12.76% 0.06%
28 83.45% 16.55% 7.46% 9.07% 0.02% 93 76.40% 23.60% 10.72% 12.82% 0.06%
29 83.35% 16.65% 7.50% 9.13% 0.02% 94 76.31% 23.69% 10.76% 12.87% 0.06%
30 83.25% 16.75% 7.55% 9.17% 0.02% 95 76.20% 23.80% 10.81% 12.93% 0.06%
31 83.17% 16.83% 7.59% 9.22% 0.02% 96 76.08% 23.92% 10.86% 13.00% 0.06%
32 83.06% 16.94% 7.64% 9.28% 0.02% 97 75.95% 24.05% 10.92% 13.07% 0.06%
33 82.96% 17.04% 7.68% 9.33% 0.03% 98 75.83% 24.18% 10.98% 13.14% 0.06%
34 82.85% 17.15% 7.73% 9.39% 0.03% 99 75.73% 24.27% 11.02% 13.19% 0.06%
35 82.75% 17.25% 7.78% 9.45% 0.03% 100 75.62% 24.39% 11.08% 13.25% 0.06%
36 82.66% 17.35% 7.82% 9.49% 0.03% 101 75.50% 24.51% 11.12% 13.32% 0.06%
37 82.56% 17.44% 7.87% 9.54% 0.03% 102 75.39% 24.61% 11.17% 13.37% 0.07%
38 82.46% 17.54% 7.92% 9.59% 0.03% 103 75.29% 24.71% 11.22% 13.43% 0.07%
39 82.37% 17.63% 7.96% 9.64% 0.03% 104 75.18% 24.82% 11.27% 13.48% 0.07%
40 82.27% 17.73% 8.01% 9.69% 0.03% 105 75.07% 24.93% 11.33% 13.54% 0.07%
41 82.17% 17.83% 8.06% 9.74% 0.03% 106 74.95% 25.05% 11.38% 13.60% 0.07%
42 82.06% 17.94% 8.11% 9.80% 0.04% 107 74.86% 25.14% 11.42% 13.65% 0.07%
43 81.96% 18.04% 8.16% 9.84% 0.04% 108 74.74% 25.27% 11.47% 13.72% 0.07%
44 81.85% 18.15% 8.21% 9.91% 0.04% 109 74.62% 25.39% 11.53% 13.78% 0.07%
45 81.74% 18.26% 8.26% 9.96% 0.04% 110 74.51% 25.50% 11.58% 13.84% 0.07%
46 81.63% 18.37% 8.32% 10.01% 0.04% 111 74.41% 25.59% 11.62% 13.90% 0.08%
47 81.51% 18.49% 8.37% 10.08% 0.04% 112 74.29% 25.72% 11.67% 13.97% 0.08%
48 81.42% 18.58% 8.41% 10.14% 0.04% 113 74.15% 25.85% 11.73% 14.05% 0.08%
49 81.32% 18.68% 8.45% 10.19% 0.04% 114 74.04% 25.96% 11.77% 14.11% 0.08%
50 81.20% 18.81% 8.52% 10.25% 0.04% 115 73.92% 26.08% 11.83% 14.18% 0.08%
51 81.11% 18.89% 8.56% 10.30% 0.04% 116 73.79% 26.21% 11.88% 14.24% 0.08%
52 81.01% 18.99% 8.60% 10.35% 0.04% 117 73.67% 26.33% 11.93% 14.31% 0.08%
53 80.90% 19.10% 8.65% 10.41% 0.04% 118 73.55% 26.45% 11.99% 14.38% 0.09%
54 80.78% 19.22% 8.71% 10.48% 0.04% 119 73.45% 26.55% 12.03% 14.43% 0.09%
55 80.67% 19.33% 8.75% 10.54% 0.04% 120 73.33% 26.67% 12.08% 14.50% 0.09%
56 80.56% 19.45% 8.80% 10.60% 0.04% 121 73.23% 26.77% 12.13% 14.55% 0.09%
57 80.45% 19.55% 8.86% 10.65% 0.04% 122 73.10% 26.90% 12.19% 14.62% 0.09%
58 80.33% 19.67% 8.91% 10.71% 0.04% 123 72.99% 27.01% 12.24% 14.68% 0.09%
59 80.23% 19.77% 8.96% 10.77% 0.04% 124 72.88% 27.12% 12.29% 14.74% 0.09%
60 80.12% 19.88% 9.01% 10.83% 0.04% 125 72.76% 27.24% 12.35% 14.80% 0.10%
61 80.02% 19.98% 9.06% 10.88% 0.04% 126 72.65% 27.35% 12.39% 14.86% 0.10%
62 79.91% 20.09% 9.12% 10.93% 0.04% 127 72.53% 27.47% 12.45% 14.92% 0.10%
63 79.82% 20.18% 9.16% 10.98% 0.04% 128 72.41% 27.59% 12.51% 14.99% 0.10%
64 79.71% 20.29% 9.21% 11.04% 0.04% 129 72.28% 27.72% 12.55% 15.06% 0.10%
65 79.59% 20.41% 9.27% 11.10% 0.04% 130 72.17% 27.83% 12.61% 15.12% 0.11%
66 79.48% 20.53% 9.33% 11.16% 0.04% 131 72.05% 27.95% 12.65% 15.19% 0.11%
67 79.36% 20.64% 9.39% 11.21% 0.05% 132 71.94% 28.07% 12.69% 15.26% 0.11%
68 79.25% 20.75% 9.43% 11.27% 0.05% 133 71.82% 28.18% 12.75% 15.32% 0.11%
69 79.13% 20.87% 9.48% 11.34% 0.05% 134 71.69% 28.31% 12.80% 15.40% 0.12%
70 79.02% 20.98% 9.54% 11.39% 0.05% 135 71.57% 28.43% 12.84% 15.47% 0.12%
71 78.91% 21.09% 9.59% 11.45% 0.05% 136 71.47% 28.53% 12.90% 15.52% 0.12%
72 78.79% 21.21% 9.64% 11.53% 0.05% 137 71.36% 28.64% 12.95% 15.57% 0.12%
73 78.68% 21.32% 9.69% 11.58% 0.05% 138 71.24% 28.76% 13.00% 15.64% 0.12%
74 78.57% 21.43% 9.74% 11.64% 0.05% 139 71.14% 28.86% 13.04% 15.70% 0.12%
75 78.45% 21.55% 9.79% 11.71% 0.05% 140 71.03% 28.98% 13.09% 15.76% 0.12%
76 78.33% 21.67% 9.85% 11.77% 0.05% 141 70.90% 29.10% 13.15% 15.82% 0.13%
77 78.21% 21.79% 9.90% 11.83% 0.05% 142 70.80% 29.21% 13.19% 15.89% 0.13%
78 78.10% 21.90% 9.95% 11.90% 0.05% 143 70.68% 29.32% 13.24% 15.95% 0.13%
79 77.97% 22.03% 10.02% 11.96% 0.05% 144 70.57% 29.43% 13.28% 16.01% 0.13%
80 77.85% 22.15% 10.08% 12.02% 0.05% 145 70.47% 29.53% 13.32% 16.08% 0.13%
81 77.77% 22.23% 10.11% 12.07% 0.05% 146 70.37% 29.63% 13.36% 16.13% 0.14%
82 77.65% 22.35% 10.17% 12.14% 0.05% 147 70.26% 29.74% 13.42% 16.19% 0.14%
83 77.53% 22.47% 10.22% 12.20% 0.05% 148 70.14% 29.86% 13.47% 16.26% 0.14%
209
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 149 70.02% 29.98% 13.52% 16.32% 0.14% 214 63.07% 36.93% 16.48% 20.11% 0.34%
150 69.89% 30.11% 13.58% 16.38% 0.15% 215 62.96% 37.04% 16.53% 20.17% 0.34%
151 69.78% 30.22% 13.61% 16.46% 0.15% 216 62.86% 37.14% 16.57% 20.22% 0.35%
152 69.67% 30.33% 13.67% 16.51% 0.15% 217 62.77% 37.23% 16.61% 20.27% 0.36%
153 69.55% 30.45% 13.72% 16.57% 0.16% 218 62.66% 37.34% 16.65% 20.34% 0.36%
154 69.45% 30.55% 13.76% 16.63% 0.16% 219 62.56% 37.44% 16.69% 20.38% 0.36%
155 69.34% 30.66% 13.82% 16.68% 0.16% 220 62.46% 37.54% 16.73% 20.45% 0.37%
156 69.21% 30.79% 13.87% 16.76% 0.17% 221 62.35% 37.65% 16.77% 20.51% 0.37%
157 69.12% 30.88% 13.91% 16.81% 0.17% 222 62.25% 37.75% 16.82% 20.56% 0.38%
158 69.00% 31.00% 13.95% 16.87% 0.17% 223 62.15% 37.85% 16.86% 20.61% 0.38%
159 68.90% 31.10% 13.99% 16.94% 0.17% 224 62.06% 37.94% 16.89% 20.67% 0.38%
160 68.80% 31.21% 14.03% 17.00% 0.17% 225 61.97% 38.03% 16.92% 20.72% 0.39%
161 68.68% 31.32% 14.09% 17.06% 0.18% 226 61.88% 38.12% 16.96% 20.77% 0.39%
162 68.55% 31.45% 14.14% 17.13% 0.18% 227 61.78% 38.22% 17.00% 20.83% 0.40%
163 68.44% 31.56% 14.20% 17.18% 0.18% 228 61.68% 38.32% 17.04% 20.88% 0.40%
164 68.33% 31.67% 14.25% 17.24% 0.18% 229 61.60% 38.41% 17.07% 20.93% 0.40%
165 68.22% 31.78% 14.30% 17.30% 0.19% 230 61.48% 38.52% 17.12% 20.99% 0.41%
166 68.10% 31.90% 14.35% 17.36% 0.19% 231 61.38% 38.62% 17.16% 21.05% 0.42%
167 68.01% 31.99% 14.39% 17.42% 0.19% 232 61.26% 38.74% 17.21% 21.11% 0.42%
168 67.91% 32.09% 14.43% 17.47% 0.19% 233 61.16% 38.84% 17.25% 21.16% 0.43%
169 67.81% 32.19% 14.47% 17.53% 0.20% 234 61.05% 38.95% 17.29% 21.23% 0.43%
170 67.69% 32.31% 14.52% 17.60% 0.20% 235 60.95% 39.05% 17.33% 21.29% 0.43%
171 67.60% 32.41% 14.55% 17.65% 0.20% 236 60.85% 39.15% 17.37% 21.34% 0.44%
172 67.48% 32.52% 14.60% 17.72% 0.20% 237 60.74% 39.26% 17.42% 21.40% 0.44%
173 67.35% 32.65% 14.66% 17.79% 0.21% 238 60.65% 39.35% 17.46% 21.46% 0.44%
174 67.23% 32.78% 14.71% 17.86% 0.21% 239 60.52% 39.48% 17.51% 21.52% 0.45%
175 67.11% 32.89% 14.76% 17.91% 0.22% 240 60.43% 39.57% 17.56% 21.56% 0.45%
176 67.00% 33.00% 14.81% 17.97% 0.22% 241 60.35% 39.65% 17.60% 21.60% 0.46%
177 66.88% 33.12% 14.87% 18.03% 0.22% 242 60.25% 39.76% 17.64% 21.65% 0.46%
178 66.77% 33.23% 14.91% 18.09% 0.23% 243 60.15% 39.85% 17.67% 21.71% 0.47%
179 66.66% 33.34% 14.97% 18.14% 0.23% 244 60.06% 39.94% 17.71% 21.76% 0.47%
180 66.54% 33.46% 15.02% 18.21% 0.23% 245 59.96% 40.04% 17.75% 21.82% 0.47%
181 66.43% 33.57% 15.05% 18.28% 0.24% 246 59.88% 40.12% 17.78% 21.86% 0.48%
182 66.33% 33.67% 15.09% 18.35% 0.24% 247 59.78% 40.22% 17.82% 21.92% 0.49%
183 66.23% 33.77% 15.12% 18.40% 0.24% 248 59.68% 40.32% 17.86% 21.97% 0.49%
184 66.14% 33.86% 15.17% 18.45% 0.25% 249 59.61% 40.39% 17.89% 22.01% 0.49%
185 66.05% 33.95% 15.20% 18.50% 0.25% 250 59.51% 40.49% 17.93% 22.06% 0.50%
186 65.96% 34.04% 15.24% 18.55% 0.25% 251 59.42% 40.59% 17.96% 22.12% 0.51%
187 65.86% 34.14% 15.29% 18.60% 0.25% 252 59.32% 40.68% 18.00% 22.17% 0.51%
188 65.76% 34.24% 15.32% 18.66% 0.26% 253 59.22% 40.78% 18.04% 22.23% 0.51%
189 65.65% 34.35% 15.37% 18.73% 0.26% 254 59.12% 40.88% 18.08% 22.28% 0.51%
190 65.54% 34.46% 15.40% 18.80% 0.26% 255 59.03% 40.97% 18.12% 22.34% 0.52%
191 65.42% 34.58% 15.45% 18.86% 0.27% 256 58.94% 41.06% 18.16% 22.38% 0.52%
192 65.33% 34.67% 15.50% 18.91% 0.27% 257 58.86% 41.14% 18.19% 22.42% 0.52%
193 65.21% 34.79% 15.55% 18.97% 0.27% 258 58.77% 41.23% 18.22% 22.48% 0.53%
194 65.12% 34.88% 15.59% 19.02% 0.27% 259 58.68% 41.32% 18.25% 22.54% 0.53%
195 65.03% 34.97% 15.63% 19.06% 0.28% 260 58.58% 41.42% 18.30% 22.59% 0.53%
196 64.92% 35.08% 15.68% 19.12% 0.28% 261 58.49% 41.51% 18.33% 22.64% 0.54%
197 64.81% 35.19% 15.73% 19.18% 0.28% 262 58.38% 41.62% 18.37% 22.71% 0.54%
198 64.69% 35.32% 15.79% 19.24% 0.28% 263 58.29% 41.71% 18.40% 22.77% 0.54%
199 64.59% 35.42% 15.83% 19.30% 0.29% 264 58.20% 41.80% 18.43% 22.82% 0.55%
200 64.47% 35.53% 15.88% 19.36% 0.29% 265 58.10% 41.90% 18.47% 22.88% 0.55%
201 64.36% 35.64% 15.92% 19.42% 0.30% 266 58.01% 41.99% 18.51% 22.93% 0.56%
202 64.26% 35.74% 15.96% 19.48% 0.30% 267 57.92% 42.08% 18.54% 22.98% 0.56%
203 64.16% 35.84% 16.00% 19.54% 0.30% 268 57.84% 42.17% 18.58% 23.02% 0.56%
204 64.06% 35.94% 16.05% 19.58% 0.30% 269 57.74% 42.27% 18.62% 23.07% 0.57%
205 63.97% 36.03% 16.09% 19.63% 0.31% 270 57.65% 42.35% 18.66% 23.12% 0.58%
206 63.85% 36.15% 16.16% 19.69% 0.31% 271 57.57% 42.43% 18.69% 23.17% 0.58%
207 63.75% 36.25% 16.20% 19.74% 0.31% 272 57.49% 42.52% 18.73% 23.21% 0.58%
208 63.66% 36.34% 16.23% 19.79% 0.32% 273 57.38% 42.62% 18.76% 23.27% 0.59%
209 63.57% 36.43% 16.27% 19.84% 0.32% 274 57.28% 42.72% 18.81% 23.32% 0.59%
210 63.47% 36.54% 16.32% 19.89% 0.32% 275 57.21% 42.79% 18.83% 23.37% 0.60%
211 63.36% 36.64% 16.36% 19.96% 0.33% 276 57.10% 42.90% 18.88% 23.42% 0.60%
212 63.25% 36.75% 16.40% 20.02% 0.33% 277 57.00% 43.00% 18.92% 23.47% 0.60%
213 63.16% 36.84% 16.44% 20.07% 0.34% 278 56.90% 43.10% 18.96% 23.53% 0.61%
210
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 279 56.82% 43.18% 18.99% 23.58% 0.61% 344 51.59% 48.41% 21.09% 26.44% 0.89%
280 56.73% 43.27% 19.03% 23.62% 0.62% 345 51.51% 48.49% 21.12% 26.48% 0.89%
281 56.66% 43.34% 19.06% 23.66% 0.62% 346 51.41% 48.59% 21.16% 26.53% 0.90%
282 56.56% 43.44% 19.10% 23.72% 0.62% 347 51.35% 48.66% 21.19% 26.56% 0.90%
283 56.48% 43.52% 19.13% 23.76% 0.63% 348 51.26% 48.74% 21.23% 26.61% 0.91%
284 56.39% 43.61% 19.16% 23.82% 0.63% 349 51.18% 48.82% 21.26% 26.65% 0.91%
285 56.31% 43.69% 19.18% 23.88% 0.64% 350 51.08% 48.92% 21.30% 26.71% 0.91%
286 56.21% 43.79% 19.23% 23.93% 0.64% 351 51.00% 49.00% 21.33% 26.76% 0.92%
287 56.13% 43.87% 19.25% 23.97% 0.65% 352 50.94% 49.06% 21.35% 26.79% 0.92%
288 56.05% 43.95% 19.28% 24.02% 0.65% 353 50.87% 49.14% 21.38% 26.83% 0.93%
289 55.97% 44.03% 19.32% 24.06% 0.66% 354 50.79% 49.21% 21.40% 26.88% 0.94%
290 55.88% 44.12% 19.36% 24.09% 0.66% 355 50.72% 49.28% 21.42% 26.92% 0.94%
291 55.81% 44.19% 19.40% 24.12% 0.67% 356 50.65% 49.35% 21.44% 26.96% 0.95%
292 55.73% 44.27% 19.43% 24.17% 0.67% 357 50.60% 49.40% 21.46% 26.98% 0.96%
293 55.65% 44.35% 19.45% 24.22% 0.68% 358 50.53% 49.47% 21.49% 27.02% 0.96%
294 55.57% 44.43% 19.48% 24.26% 0.68% 359 50.47% 49.53% 21.51% 27.06% 0.96%
295 55.48% 44.52% 19.52% 24.31% 0.69% 360 50.38% 49.62% 21.55% 27.10% 0.96%
296 55.41% 44.59% 19.54% 24.35% 0.69% 361 50.30% 49.70% 21.58% 27.14% 0.97%
297 55.33% 44.67% 19.58% 24.40% 0.69% 362 50.23% 49.77% 21.61% 27.18% 0.98%
298 55.24% 44.76% 19.61% 24.46% 0.70% 363 50.16% 49.84% 21.64% 27.22% 0.98%
299 55.16% 44.84% 19.64% 24.50% 0.70% 364 50.07% 49.93% 21.66% 27.27% 0.99%
300 55.08% 44.92% 19.67% 24.54% 0.70% 365 50.02% 49.98% 21.69% 27.30% 0.99%
301 55.02% 44.98% 19.69% 24.58% 0.71% 366 49.96% 50.04% 21.71% 27.33% 1.00%
302 54.93% 45.07% 19.74% 24.62% 0.71% 367 49.90% 50.10% 21.72% 27.37% 1.01%
303 54.86% 45.14% 19.76% 24.66% 0.71% 368 49.83% 50.17% 21.76% 27.40% 1.01%
304 54.79% 45.21% 19.80% 24.70% 0.72% 369 49.77% 50.23% 21.78% 27.43% 1.02%
305 54.71% 45.29% 19.83% 24.74% 0.72% 370 49.68% 50.32% 21.82% 27.47% 1.02%
306 54.61% 45.39% 19.87% 24.79% 0.73% 371 49.62% 50.38% 21.84% 27.52% 1.03%
307 54.54% 45.46% 19.90% 24.83% 0.73% 372 49.55% 50.45% 21.87% 27.55% 1.03%
308 54.46% 45.54% 19.94% 24.87% 0.73% 373 49.47% 50.53% 21.90% 27.59% 1.04%
309 54.38% 45.62% 19.97% 24.91% 0.74% 374 49.39% 50.61% 21.94% 27.63% 1.04%
310 54.30% 45.71% 20.01% 24.96% 0.74% 375 49.32% 50.68% 21.96% 27.67% 1.05%
311 54.20% 45.80% 20.05% 25.01% 0.74% 376 49.24% 50.76% 21.99% 27.73% 1.05%
312 54.10% 45.90% 20.08% 25.07% 0.75% 377 49.18% 50.82% 22.01% 27.76% 1.05%
313 54.01% 45.99% 20.12% 25.12% 0.75% 378 49.10% 50.90% 22.04% 27.80% 1.06%
314 53.94% 46.06% 20.15% 25.16% 0.76% 379 49.04% 50.96% 22.06% 27.84% 1.06%
315 53.85% 46.15% 20.18% 25.21% 0.76% 380 48.98% 51.03% 22.09% 27.87% 1.06%
316 53.78% 46.22% 20.22% 25.24% 0.76% 381 48.91% 51.09% 22.12% 27.90% 1.07%
317 53.70% 46.30% 20.25% 25.29% 0.77% 382 48.82% 51.18% 22.15% 27.95% 1.07%
318 53.62% 46.38% 20.29% 25.32% 0.77% 383 48.75% 51.25% 22.19% 27.99% 1.08%
319 53.54% 46.46% 20.32% 25.36% 0.78% 384 48.68% 51.32% 22.21% 28.02% 1.08%
320 53.45% 46.55% 20.36% 25.41% 0.78% 385 48.61% 51.39% 22.24% 28.07% 1.09%
321 53.38% 46.62% 20.39% 25.45% 0.78% 386 48.54% 51.46% 22.26% 28.11% 1.09%
322 53.30% 46.70% 20.42% 25.49% 0.78% 387 48.48% 51.52% 22.28% 28.14% 1.10%
323 53.24% 46.77% 20.45% 25.53% 0.79% 388 48.41% 51.59% 22.31% 28.18% 1.10%
324 53.17% 46.83% 20.48% 25.56% 0.79% 389 48.34% 51.67% 22.33% 28.23% 1.11%
325 53.08% 46.92% 20.51% 25.61% 0.79% 390 48.27% 51.73% 22.36% 28.26% 1.11%
326 53.01% 46.99% 20.54% 25.66% 0.80% 391 48.20% 51.80% 22.39% 28.30% 1.11%
327 52.94% 47.06% 20.57% 25.69% 0.81% 392 48.13% 51.88% 22.42% 28.34% 1.12%
328 52.86% 47.14% 20.59% 25.74% 0.81% 393 48.06% 51.94% 22.45% 28.37% 1.12%
329 52.78% 47.22% 20.62% 25.78% 0.81% 394 47.99% 52.01% 22.48% 28.41% 1.12%
330 52.69% 47.31% 20.65% 25.83% 0.82% 395 47.92% 52.08% 22.50% 28.45% 1.13%
331 52.61% 47.39% 20.70% 25.87% 0.83% 396 47.87% 52.13% 22.53% 28.48% 1.13%
332 52.53% 47.47% 20.73% 25.91% 0.83% 397 47.80% 52.20% 22.56% 28.51% 1.13%
333 52.45% 47.55% 20.76% 25.95% 0.84% 398 47.75% 52.26% 22.58% 28.54% 1.14%
334 52.38% 47.62% 20.78% 26.00% 0.84% 399 47.68% 52.32% 22.60% 28.58% 1.14%
335 52.29% 47.71% 20.81% 26.05% 0.84% 400 47.60% 52.40% 22.64% 28.62% 1.14%
336 52.22% 47.79% 20.85% 26.09% 0.85% 401 47.53% 52.47% 22.67% 28.66% 1.15%
337 52.14% 47.86% 20.88% 26.13% 0.86% 402 47.48% 52.52% 22.69% 28.68% 1.16%
338 52.05% 47.95% 20.91% 26.18% 0.86% 403 47.42% 52.58% 22.71% 28.71% 1.16%
339 51.97% 48.04% 20.94% 26.23% 0.87% 404 47.37% 52.63% 22.73% 28.74% 1.16%
340 51.90% 48.10% 20.97% 26.26% 0.87% 405 47.31% 52.69% 22.75% 28.78% 1.17%
341 51.82% 48.19% 21.01% 26.30% 0.88% 406 47.24% 52.77% 22.78% 28.81% 1.17%
342 51.75% 48.26% 21.04% 26.34% 0.88% 407 47.18% 52.82% 22.80% 28.84% 1.18%
343 51.66% 48.34% 21.06% 26.39% 0.88% 408 47.11% 52.89% 22.83% 28.88% 1.19%
211
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 409 47.05% 52.96% 22.85% 28.91% 1.19% 474 43.16% 56.84% 24.33% 31.05% 1.46%
410 47.00% 53.01% 22.87% 28.94% 1.20% 475 43.11% 56.89% 24.35% 31.08% 1.46%
411 46.93% 53.07% 22.89% 28.98% 1.20% 476 43.04% 56.96% 24.37% 31.11% 1.47%
412 46.86% 53.14% 22.92% 29.02% 1.20% 477 42.98% 57.02% 24.39% 31.16% 1.47%
413 46.81% 53.19% 22.94% 29.05% 1.21% 478 42.93% 57.07% 24.41% 31.19% 1.47%
414 46.76% 53.24% 22.96% 29.08% 1.21% 479 42.88% 57.12% 24.44% 31.21% 1.48%
415 46.71% 53.29% 22.98% 29.10% 1.21% 480 42.84% 57.16% 24.45% 31.23% 1.48%
416 46.65% 53.35% 23.00% 29.13% 1.22% 481 42.78% 57.22% 24.47% 31.27% 1.48%
417 46.59% 53.42% 23.02% 29.17% 1.22% 482 42.73% 57.27% 24.49% 31.30% 1.49%
418 46.50% 53.50% 23.05% 29.22% 1.23% 483 42.66% 57.34% 24.51% 31.34% 1.49%
419 46.43% 53.57% 23.08% 29.26% 1.23% 484 42.61% 57.39% 24.53% 31.37% 1.49%
420 46.35% 53.65% 23.11% 29.30% 1.24% 485 42.55% 57.45% 24.55% 31.41% 1.49%
421 46.29% 53.71% 23.13% 29.34% 1.24% 486 42.50% 57.50% 24.57% 31.44% 1.49%
422 46.24% 53.76% 23.15% 29.37% 1.25% 487 42.44% 57.56% 24.60% 31.47% 1.50%
423 46.19% 53.81% 23.16% 29.39% 1.25% 488 42.38% 57.62% 24.62% 31.50% 1.50%
424 46.13% 53.87% 23.19% 29.42% 1.26% 489 42.33% 57.67% 24.65% 31.53% 1.50%
425 46.06% 53.94% 23.22% 29.46% 1.26% 490 42.28% 57.72% 24.66% 31.55% 1.51%
426 46.01% 53.99% 23.24% 29.49% 1.26% 491 42.23% 57.77% 24.68% 31.59% 1.51%
427 45.95% 54.05% 23.27% 29.52% 1.26% 492 42.19% 57.81% 24.69% 31.61% 1.51%
428 45.88% 54.12% 23.29% 29.56% 1.27% 493 42.13% 57.87% 24.72% 31.64% 1.51%
429 45.82% 54.18% 23.32% 29.59% 1.27% 494 42.08% 57.92% 24.73% 31.67% 1.52%
430 45.74% 54.26% 23.35% 29.64% 1.28% 495 42.03% 57.97% 24.75% 31.70% 1.52%
431 45.68% 54.32% 23.37% 29.67% 1.28% 496 41.98% 58.03% 24.77% 31.73% 1.53%
432 45.62% 54.38% 23.39% 29.71% 1.29% 497 41.90% 58.10% 24.79% 31.78% 1.54%
433 45.56% 54.45% 23.41% 29.74% 1.29% 498 41.84% 58.16% 24.82% 31.81% 1.54%
434 45.49% 54.51% 23.44% 29.78% 1.29% 499 41.77% 58.23% 24.84% 31.84% 1.54%
435 45.45% 54.55% 23.45% 29.80% 1.29% 500 41.72% 58.28% 24.87% 31.87% 1.55%
436 45.39% 54.61% 23.48% 29.83% 1.30% 501 41.66% 58.34% 24.88% 31.91% 1.55%
437 45.33% 54.67% 23.51% 29.86% 1.30% 502 41.62% 58.38% 24.90% 31.94% 1.55%
438 45.27% 54.73% 23.53% 29.89% 1.31% 503 41.56% 58.44% 24.92% 31.97% 1.55%
439 45.22% 54.78% 23.55% 29.92% 1.31% 504 41.51% 58.49% 24.94% 32.00% 1.56%
440 45.16% 54.84% 23.57% 29.96% 1.32% 505 41.46% 58.55% 24.95% 32.04% 1.56%
441 45.10% 54.90% 23.59% 29.99% 1.32% 506 41.40% 58.60% 24.97% 32.08% 1.56%
442 45.04% 54.96% 23.61% 30.02% 1.33% 507 41.35% 58.65% 24.99% 32.10% 1.56%
443 44.97% 55.03% 23.64% 30.06% 1.33% 508 41.30% 58.70% 25.01% 32.13% 1.57%
444 44.91% 55.09% 23.66% 30.09% 1.34% 509 41.25% 58.76% 25.03% 32.16% 1.57%
445 44.86% 55.14% 23.68% 30.12% 1.34% 510 41.19% 58.81% 25.05% 32.19% 1.57%
446 44.80% 55.20% 23.70% 30.15% 1.34% 511 41.13% 58.87% 25.08% 32.22% 1.57%
447 44.74% 55.26% 23.73% 30.18% 1.35% 512 41.06% 58.94% 25.10% 32.26% 1.58%
448 44.69% 55.32% 23.75% 30.22% 1.35% 513 41.01% 58.99% 25.12% 32.29% 1.58%
449 44.63% 55.37% 23.77% 30.25% 1.36% 514 40.97% 59.03% 25.14% 32.31% 1.58%
450 44.57% 55.43% 23.79% 30.28% 1.36% 515 40.91% 59.09% 25.16% 32.34% 1.58%
451 44.51% 55.49% 23.81% 30.31% 1.36% 516 40.86% 59.14% 25.18% 32.37% 1.59%
452 44.45% 55.55% 23.83% 30.35% 1.37% 517 40.80% 59.20% 25.20% 32.41% 1.59%
453 44.39% 55.62% 23.86% 30.38% 1.37% 518 40.75% 59.25% 25.21% 32.44% 1.59%
454 44.32% 55.68% 23.89% 30.42% 1.38% 519 40.69% 59.31% 25.22% 32.49% 1.60%
455 44.25% 55.75% 23.93% 30.44% 1.38% 520 40.64% 59.37% 25.24% 32.52% 1.60%
456 44.19% 55.81% 23.95% 30.47% 1.39% 521 40.59% 59.41% 25.26% 32.55% 1.61%
457 44.13% 55.87% 23.97% 30.51% 1.40% 522 40.54% 59.46% 25.28% 32.58% 1.61%
458 44.08% 55.92% 23.99% 30.53% 1.40% 523 40.49% 59.51% 25.29% 32.61% 1.61%
459 44.04% 55.97% 24.01% 30.56% 1.40% 524 40.44% 59.56% 25.31% 32.64% 1.62%
460 43.98% 56.02% 24.02% 30.59% 1.41% 525 40.39% 59.61% 25.32% 32.67% 1.62%
461 43.92% 56.08% 24.04% 30.63% 1.41% 526 40.35% 59.65% 25.34% 32.70% 1.62%
462 43.85% 56.15% 24.07% 30.67% 1.41% 527 40.29% 59.71% 25.35% 32.73% 1.63%
463 43.80% 56.21% 24.09% 30.70% 1.41% 528 40.24% 59.76% 25.37% 32.76% 1.63%
464 43.73% 56.27% 24.11% 30.74% 1.42% 529 40.20% 59.80% 25.38% 32.78% 1.64%
465 43.69% 56.31% 24.13% 30.76% 1.42% 530 40.17% 59.83% 25.40% 32.80% 1.64%
466 43.63% 56.37% 24.16% 30.79% 1.43% 531 40.12% 59.88% 25.42% 32.83% 1.64%
467 43.58% 56.43% 24.18% 30.82% 1.43% 532 40.07% 59.93% 25.44% 32.85% 1.64%
468 43.53% 56.47% 24.19% 30.84% 1.43% 533 40.00% 60.00% 25.47% 32.89% 1.64%
469 43.48% 56.52% 24.21% 30.87% 1.44% 534 39.96% 60.05% 25.47% 32.92% 1.65%
470 43.42% 56.58% 24.24% 30.90% 1.44% 535 39.89% 60.11% 25.50% 32.96% 1.65%
471 43.36% 56.64% 24.26% 30.94% 1.45% 536 39.85% 60.15% 25.51% 32.99% 1.65%
472 43.30% 56.70% 24.28% 30.97% 1.45% 537 39.80% 60.20% 25.52% 33.02% 1.66%
473 43.23% 56.77% 24.31% 31.01% 1.45% 538 39.75% 60.25% 25.54% 33.06% 1.66%
212
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 539 39.70% 60.30% 25.55% 33.08% 1.66% 604 36.76% 63.24% 26.61% 34.74% 1.89%
540 39.66% 60.34% 25.57% 33.11% 1.67% 605 36.71% 63.29% 26.63% 34.77% 1.90%
541 39.61% 60.39% 25.58% 33.13% 1.67% 606 36.68% 63.32% 26.64% 34.79% 1.90%
542 39.56% 60.44% 25.60% 33.16% 1.68% 607 36.63% 63.37% 26.66% 34.81% 1.90%
543 39.51% 60.50% 25.62% 33.20% 1.68% 608 36.59% 63.41% 26.67% 34.83% 1.91%
544 39.46% 60.54% 25.64% 33.22% 1.68% 609 36.55% 63.45% 26.69% 34.86% 1.91%
545 39.41% 60.59% 25.66% 33.25% 1.68% 610 36.51% 63.49% 26.70% 34.89% 1.91%
546 39.36% 60.64% 25.67% 33.28% 1.69% 611 36.46% 63.54% 26.71% 34.92% 1.91%
547 39.31% 60.69% 25.69% 33.31% 1.69% 612 36.42% 63.58% 26.74% 34.93% 1.92%
548 39.27% 60.73% 25.70% 33.34% 1.69% 613 36.37% 63.63% 26.75% 34.97% 1.92%
549 39.24% 60.77% 25.71% 33.36% 1.70% 614 36.32% 63.68% 26.76% 34.99% 1.92%
550 39.19% 60.81% 25.73% 33.38% 1.70% 615 36.28% 63.72% 26.78% 35.02% 1.93%
551 39.13% 60.87% 25.76% 33.41% 1.70% 616 36.23% 63.77% 26.79% 35.04% 1.93%
552 39.09% 60.91% 25.77% 33.43% 1.71% 617 36.19% 63.81% 26.81% 35.07% 1.93%
553 39.04% 60.96% 25.79% 33.46% 1.71% 618 36.15% 63.85% 26.83% 35.09% 1.93%
554 38.98% 61.02% 25.81% 33.49% 1.71% 619 36.10% 63.90% 26.85% 35.12% 1.94%
555 38.93% 61.07% 25.83% 33.52% 1.72% 620 36.05% 63.95% 26.86% 35.15% 1.94%
556 38.88% 61.12% 25.85% 33.55% 1.72% 621 36.00% 64.00% 26.88% 35.18% 1.94%
557 38.84% 61.16% 25.86% 33.57% 1.73% 622 35.96% 64.04% 26.89% 35.20% 1.94%
558 38.80% 61.20% 25.87% 33.60% 1.73% 623 35.93% 64.07% 26.90% 35.23% 1.95%
559 38.75% 61.25% 25.88% 33.63% 1.74% 624 35.90% 64.10% 26.92% 35.24% 1.95%
560 38.71% 61.29% 25.90% 33.65% 1.74% 625 35.86% 64.14% 26.93% 35.26% 1.95%
561 38.66% 61.34% 25.92% 33.68% 1.74% 626 35.82% 64.18% 26.94% 35.28% 1.96%
562 38.62% 61.38% 25.94% 33.70% 1.74% 627 35.77% 64.23% 26.96% 35.31% 1.96%
563 38.57% 61.43% 25.95% 33.73% 1.75% 628 35.73% 64.27% 26.98% 35.33% 1.96%
564 38.54% 61.46% 25.97% 33.74% 1.75% 629 35.68% 64.32% 26.99% 35.36% 1.97%
565 38.49% 61.51% 25.98% 33.77% 1.76% 630 35.64% 64.36% 27.01% 35.38% 1.98%
566 38.45% 61.55% 26.00% 33.79% 1.77% 631 35.59% 64.41% 27.03% 35.40% 1.98%
567 38.40% 61.60% 26.01% 33.82% 1.77% 632 35.54% 64.46% 27.05% 35.43% 1.98%
568 38.36% 61.64% 26.02% 33.85% 1.77% 633 35.49% 64.51% 27.07% 35.45% 1.98%
569 38.31% 61.69% 26.04% 33.87% 1.78% 634 35.45% 64.55% 27.08% 35.48% 1.98%
570 38.28% 61.73% 26.06% 33.89% 1.78% 635 35.41% 64.59% 27.10% 35.50% 1.99%
571 38.23% 61.78% 26.08% 33.91% 1.79% 636 35.38% 64.62% 27.12% 35.51% 1.99%
572 38.19% 61.81% 26.08% 33.94% 1.79% 637 35.36% 64.64% 27.12% 35.53% 2.00%
573 38.14% 61.86% 26.10% 33.96% 1.79% 638 35.32% 64.68% 27.14% 35.55% 2.00%
574 38.11% 61.89% 26.11% 33.98% 1.80% 639 35.28% 64.72% 27.15% 35.57% 2.00%
575 38.05% 61.95% 26.13% 34.01% 1.80% 640 35.23% 64.77% 27.16% 35.60% 2.01%
576 38.01% 61.99% 26.14% 34.04% 1.80% 641 35.19% 64.81% 27.18% 35.62% 2.01%
577 37.97% 62.03% 26.16% 34.06% 1.81% 642 35.15% 64.85% 27.19% 35.64% 2.02%
578 37.92% 62.08% 26.19% 34.08% 1.81% 643 35.11% 64.89% 27.21% 35.66% 2.02%
579 37.87% 62.13% 26.21% 34.11% 1.82% 644 35.08% 64.92% 27.22% 35.68% 2.02%
580 37.81% 62.20% 26.23% 34.14% 1.82% 645 35.04% 64.96% 27.23% 35.70% 2.03%
581 37.77% 62.23% 26.25% 34.16% 1.82% 646 35.00% 65.00% 27.25% 35.73% 2.03%
582 37.73% 62.27% 26.27% 34.18% 1.82% 647 34.96% 65.04% 27.26% 35.75% 2.03%
583 37.68% 62.32% 26.28% 34.21% 1.83% 648 34.92% 65.08% 27.28% 35.77% 2.04%
584 37.63% 62.38% 26.30% 34.24% 1.83% 649 34.87% 65.13% 27.30% 35.79% 2.04%
585 37.59% 62.41% 26.32% 34.26% 1.83% 650 34.83% 65.17% 27.31% 35.81% 2.05%
586 37.54% 62.46% 26.34% 34.28% 1.84% 651 34.78% 65.22% 27.33% 35.83% 2.05%
587 37.50% 62.50% 26.35% 34.31% 1.84% 652 34.75% 65.25% 27.35% 35.85% 2.05%
588 37.46% 62.54% 26.37% 34.33% 1.84% 653 34.71% 65.29% 27.36% 35.87% 2.05%
589 37.42% 62.58% 26.38% 34.36% 1.84% 654 34.68% 65.33% 27.38% 35.89% 2.06%
590 37.38% 62.62% 26.39% 34.39% 1.85% 655 34.63% 65.37% 27.40% 35.92% 2.06%
591 37.33% 62.67% 26.41% 34.42% 1.85% 656 34.59% 65.41% 27.42% 35.93% 2.06%
592 37.27% 62.73% 26.43% 34.44% 1.85% 657 34.55% 65.45% 27.43% 35.95% 2.06%
593 37.23% 62.77% 26.45% 34.46% 1.86% 658 34.51% 65.49% 27.45% 35.97% 2.07%
594 37.19% 62.81% 26.46% 34.49% 1.86% 659 34.48% 65.52% 27.46% 35.99% 2.07%
595 37.15% 62.85% 26.48% 34.51% 1.87% 660 34.44% 65.56% 27.48% 36.01% 2.08%
596 37.10% 62.90% 26.49% 34.54% 1.87% 661 34.40% 65.60% 27.50% 36.03% 2.08%
597 37.04% 62.96% 26.51% 34.57% 1.88% 662 34.36% 65.64% 27.51% 36.04% 2.08%
598 37.01% 63.00% 26.53% 34.58% 1.88% 663 34.32% 65.68% 27.53% 36.06% 2.09%
599 36.97% 63.03% 26.54% 34.60% 1.88% 664 34.29% 65.71% 27.54% 36.08% 2.09%
600 36.93% 63.07% 26.56% 34.63% 1.88% 665 34.25% 65.75% 27.56% 36.10% 2.09%
601 36.89% 63.11% 26.57% 34.65% 1.89% 666 34.22% 65.78% 27.56% 36.12% 2.09%
602 36.85% 63.15% 26.58% 34.68% 1.89% 667 34.19% 65.82% 27.58% 36.14% 2.10%
603 36.80% 63.20% 26.60% 34.71% 1.89% 668 34.14% 65.86% 27.61% 36.16% 2.10%
213
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 669 34.09% 65.91% 27.63% 36.18% 2.10% 734 31.85% 68.15% 28.49% 37.39% 2.27%
670 34.05% 65.95% 27.64% 36.20% 2.10% 735 31.82% 68.18% 28.50% 37.40% 2.28%
671 34.02% 65.98% 27.66% 36.22% 2.11% 736 31.79% 68.21% 28.51% 37.42% 2.28%
672 33.97% 66.03% 27.68% 36.24% 2.11% 737 31.76% 68.25% 28.52% 37.44% 2.28%
673 33.93% 66.07% 27.69% 36.26% 2.12% 738 31.72% 68.28% 28.54% 37.45% 2.29%
674 33.89% 66.12% 27.71% 36.28% 2.12% 739 31.68% 68.32% 28.56% 37.47% 2.29%
675 33.85% 66.15% 27.72% 36.30% 2.12% 740 31.65% 68.35% 28.57% 37.49% 2.29%
676 33.82% 66.18% 27.73% 36.32% 2.13% 741 31.62% 68.38% 28.58% 37.51% 2.29%
677 33.79% 66.21% 27.74% 36.34% 2.13% 742 31.59% 68.41% 28.59% 37.53% 2.30%
678 33.75% 66.25% 27.75% 36.37% 2.13% 743 31.56% 68.44% 28.60% 37.55% 2.30%
679 33.73% 66.27% 27.77% 36.38% 2.13% 744 31.53% 68.47% 28.61% 37.56% 2.30%
680 33.70% 66.31% 27.78% 36.39% 2.14% 745 31.50% 68.50% 28.62% 37.58% 2.30%
681 33.65% 66.35% 27.80% 36.41% 2.14% 746 31.46% 68.54% 28.63% 37.60% 2.31%
682 33.63% 66.37% 27.82% 36.42% 2.14% 747 31.42% 68.58% 28.65% 37.62% 2.31%
683 33.59% 66.41% 27.83% 36.44% 2.14% 748 31.40% 68.60% 28.66% 37.63% 2.31%
684 33.55% 66.45% 27.85% 36.46% 2.15% 749 31.37% 68.63% 28.67% 37.65% 2.31%
685 33.52% 66.48% 27.86% 36.47% 2.15% 750 31.35% 68.65% 28.68% 37.65% 2.32%
686 33.49% 66.51% 27.88% 36.48% 2.15% 751 31.32% 68.69% 28.70% 37.67% 2.32%
687 33.44% 66.56% 27.90% 36.50% 2.16% 752 31.28% 68.72% 28.71% 37.68% 2.32%
688 33.40% 66.60% 27.91% 36.53% 2.16% 753 31.24% 68.76% 28.73% 37.70% 2.33%
689 33.35% 66.65% 27.93% 36.55% 2.17% 754 31.21% 68.79% 28.74% 37.72% 2.33%
690 33.32% 66.68% 27.94% 36.57% 2.17% 755 31.18% 68.82% 28.76% 37.73% 2.33%
691 33.29% 66.71% 27.96% 36.58% 2.17% 756 31.15% 68.85% 28.77% 37.75% 2.34%
692 33.25% 66.75% 27.97% 36.60% 2.17% 757 31.12% 68.89% 28.78% 37.77% 2.34%
693 33.22% 66.79% 27.99% 36.61% 2.18% 758 31.08% 68.92% 28.78% 37.79% 2.35%
694 33.18% 66.82% 28.00% 36.63% 2.18% 759 31.06% 68.94% 28.80% 37.80% 2.35%
695 33.15% 66.85% 28.01% 36.66% 2.19% 760 31.03% 68.97% 28.80% 37.81% 2.35%
696 33.12% 66.88% 28.02% 36.68% 2.19% 761 31.00% 69.00% 28.82% 37.83% 2.36%
697 33.08% 66.92% 28.03% 36.70% 2.19% 762 30.98% 69.02% 28.82% 37.84% 2.36%
698 33.04% 66.96% 28.05% 36.72% 2.19% 763 30.95% 69.05% 28.83% 37.86% 2.36%
699 33.00% 67.00% 28.06% 36.74% 2.20% 764 30.92% 69.08% 28.84% 37.88% 2.36%
700 32.97% 67.03% 28.08% 36.76% 2.20% 765 30.89% 69.11% 28.85% 37.89% 2.36%
701 32.93% 67.07% 28.10% 36.78% 2.20% 766 30.86% 69.14% 28.87% 37.90% 2.36%
702 32.90% 67.10% 28.10% 36.79% 2.20% 767 30.83% 69.17% 28.89% 37.92% 2.37%
703 32.88% 67.12% 28.11% 36.80% 2.21% 768 30.80% 69.20% 28.90% 37.93% 2.37%
704 32.85% 67.15% 28.12% 36.82% 2.21% 769 30.77% 69.23% 28.91% 37.95% 2.37%
705 32.82% 67.18% 28.13% 36.84% 2.21% 770 30.74% 69.26% 28.92% 37.97% 2.37%
706 32.78% 67.22% 28.14% 36.86% 2.21% 771 30.71% 69.29% 28.93% 37.99% 2.37%
707 32.75% 67.25% 28.16% 36.88% 2.21% 772 30.68% 69.32% 28.94% 38.01% 2.37%
708 32.72% 67.28% 28.17% 36.90% 2.21% 773 30.65% 69.35% 28.95% 38.02% 2.38%
709 32.70% 67.31% 28.18% 36.91% 2.22% 774 30.62% 69.38% 28.96% 38.04% 2.38%
710 32.66% 67.35% 28.20% 36.93% 2.22% 775 30.59% 69.41% 28.98% 38.05% 2.38%
711 32.61% 67.39% 28.22% 36.95% 2.22% 776 30.57% 69.44% 28.99% 38.06% 2.39%
712 32.58% 67.42% 28.23% 36.97% 2.22% 777 30.54% 69.46% 28.99% 38.08% 2.39%
713 32.55% 67.45% 28.23% 36.99% 2.23% 778 30.50% 69.50% 29.00% 38.10% 2.39%
714 32.51% 67.49% 28.25% 37.01% 2.23% 779 30.47% 69.53% 29.01% 38.12% 2.40%
715 32.48% 67.52% 28.26% 37.03% 2.23% 780 30.44% 69.56% 29.02% 38.13% 2.40%
716 32.44% 67.56% 28.27% 37.06% 2.23% 781 30.43% 69.57% 29.03% 38.14% 2.40%
717 32.41% 67.59% 28.28% 37.08% 2.23% 782 30.39% 69.61% 29.04% 38.16% 2.41%
718 32.38% 67.62% 28.29% 37.10% 2.24% 783 30.36% 69.64% 29.05% 38.18% 2.41%
719 32.35% 67.66% 28.30% 37.12% 2.24% 784 30.34% 69.67% 29.06% 38.19% 2.41%
720 32.31% 67.69% 28.32% 37.14% 2.24% 785 30.31% 69.69% 29.07% 38.20% 2.42%
721 32.27% 67.73% 28.33% 37.16% 2.24% 786 30.27% 69.73% 29.09% 38.22% 2.42%
722 32.24% 67.76% 28.35% 37.17% 2.24% 787 30.25% 69.75% 29.10% 38.24% 2.42%
723 32.22% 67.78% 28.36% 37.18% 2.24% 788 30.22% 69.78% 29.10% 38.26% 2.42%
724 32.19% 67.81% 28.37% 37.20% 2.24% 789 30.19% 69.81% 29.11% 38.27% 2.43%
725 32.15% 67.85% 28.38% 37.22% 2.25% 790 30.16% 69.84% 29.12% 38.29% 2.43%
726 32.11% 67.89% 28.40% 37.24% 2.25% 791 30.14% 69.86% 29.13% 38.30% 2.43%
727 32.08% 67.92% 28.41% 37.26% 2.26% 792 30.11% 69.89% 29.14% 38.32% 2.43%
728 32.05% 67.95% 28.42% 37.27% 2.26% 793 30.08% 69.92% 29.14% 38.34% 2.44%
729 32.02% 67.98% 28.43% 37.29% 2.26% 794 30.05% 69.96% 29.15% 38.36% 2.44%
730 31.98% 68.02% 28.45% 37.31% 2.26% 795 30.01% 69.99% 29.17% 38.38% 2.44%
731 31.96% 68.04% 28.46% 37.32% 2.26% 796 29.99% 70.01% 29.18% 38.40% 2.44%
732 31.92% 68.08% 28.47% 37.35% 2.27% 797 29.95% 70.05% 29.19% 38.42% 2.44%
733 31.89% 68.11% 28.48% 37.37% 2.27% 798 29.93% 70.07% 29.19% 38.43% 2.44%
214
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 799 29.90% 70.10% 29.20% 38.45% 2.45% 864 28.17% 71.83% 29.80% 39.43% 2.59%
800 29.87% 70.13% 29.22% 38.46% 2.45% 865 28.15% 71.85% 29.81% 39.45% 2.60%
801 29.83% 70.17% 29.23% 38.49% 2.45% 866 28.13% 71.87% 29.81% 39.46% 2.60%
802 29.81% 70.19% 29.24% 38.50% 2.45% 867 28.10% 71.91% 29.83% 39.47% 2.60%
803 29.79% 70.21% 29.25% 38.51% 2.46% 868 28.07% 71.93% 29.84% 39.49% 2.60%
804 29.76% 70.24% 29.25% 38.53% 2.46% 869 28.05% 71.96% 29.85% 39.51% 2.60%
805 29.74% 70.26% 29.26% 38.54% 2.46% 870 28.02% 71.98% 29.86% 39.53% 2.60%
806 29.72% 70.28% 29.27% 38.55% 2.46% 871 27.99% 72.01% 29.87% 39.54% 2.60%
807 29.69% 70.31% 29.28% 38.57% 2.46% 872 27.97% 72.03% 29.88% 39.55% 2.61%
808 29.66% 70.34% 29.30% 38.58% 2.46% 873 27.95% 72.06% 29.89% 39.56% 2.61%
809 29.62% 70.38% 29.31% 38.60% 2.46% 874 27.93% 72.07% 29.90% 39.57% 2.61%
810 29.59% 70.41% 29.32% 38.62% 2.47% 875 27.90% 72.10% 29.91% 39.58% 2.61%
811 29.56% 70.44% 29.34% 38.63% 2.47% 876 27.87% 72.13% 29.92% 39.60% 2.61%
812 29.53% 70.47% 29.34% 38.65% 2.48% 877 27.84% 72.16% 29.93% 39.61% 2.62%
813 29.50% 70.50% 29.35% 38.67% 2.48% 878 27.83% 72.17% 29.94% 39.62% 2.62%
814 29.48% 70.52% 29.36% 38.69% 2.48% 879 27.80% 72.20% 29.95% 39.63% 2.62%
815 29.44% 70.56% 29.37% 38.70% 2.49% 880 27.78% 72.22% 29.96% 39.65% 2.62%
816 29.41% 70.59% 29.38% 38.72% 2.49% 881 27.76% 72.24% 29.96% 39.66% 2.62%
817 29.39% 70.61% 29.39% 38.73% 2.49% 882 27.74% 72.26% 29.96% 39.68% 2.62%
818 29.36% 70.64% 29.40% 38.75% 2.50% 883 27.72% 72.28% 29.97% 39.69% 2.62%
819 29.33% 70.68% 29.41% 38.77% 2.50% 884 27.70% 72.30% 29.97% 39.70% 2.63%
820 29.29% 70.71% 29.42% 38.79% 2.50% 885 27.67% 72.33% 29.99% 39.71% 2.63%
821 29.27% 70.73% 29.43% 38.80% 2.50% 886 27.65% 72.35% 29.99% 39.72% 2.64%
822 29.25% 70.75% 29.44% 38.81% 2.50% 887 27.62% 72.38% 30.00% 39.74% 2.64%
823 29.23% 70.78% 29.45% 38.82% 2.51% 888 27.59% 72.41% 30.01% 39.75% 2.64%
824 29.20% 70.80% 29.45% 38.84% 2.51% 889 27.57% 72.44% 30.03% 39.76% 2.65%
825 29.17% 70.83% 29.46% 38.86% 2.51% 890 27.55% 72.45% 30.03% 39.77% 2.65%
826 29.14% 70.86% 29.47% 38.88% 2.51% 891 27.52% 72.48% 30.04% 39.79% 2.65%
827 29.11% 70.89% 29.48% 38.89% 2.51% 892 27.50% 72.51% 30.05% 39.80% 2.65%
828 29.09% 70.91% 29.49% 38.91% 2.52% 893 27.47% 72.53% 30.06% 39.81% 2.65%
829 29.07% 70.93% 29.50% 38.92% 2.52% 894 27.44% 72.56% 30.08% 39.82% 2.66%
830 29.04% 70.96% 29.51% 38.94% 2.52% 895 27.42% 72.58% 30.09% 39.83% 2.66%
831 29.00% 71.00% 29.52% 38.96% 2.52% 896 27.39% 72.61% 30.10% 39.84% 2.66%
832 28.98% 71.03% 29.54% 38.97% 2.52% 897 27.37% 72.63% 30.11% 39.86% 2.67%
833 28.95% 71.05% 29.54% 38.98% 2.52% 898 27.33% 72.67% 30.13% 39.87% 2.67%
834 28.93% 71.07% 29.55% 38.99% 2.53% 899 27.31% 72.70% 30.14% 39.89% 2.67%
835 28.90% 71.10% 29.56% 39.01% 2.53% 900 27.29% 72.72% 30.15% 39.90% 2.67%
836 28.88% 71.13% 29.57% 39.03% 2.53% 901 27.26% 72.74% 30.16% 39.91% 2.68%
837 28.85% 71.15% 29.57% 39.05% 2.54% 902 27.24% 72.76% 30.16% 39.92% 2.68%
838 28.82% 71.18% 29.58% 39.06% 2.54% 903 27.21% 72.79% 30.17% 39.93% 2.68%
839 28.80% 71.20% 29.59% 39.07% 2.54% 904 27.19% 72.81% 30.18% 39.94% 2.68%
840 28.77% 71.23% 29.60% 39.09% 2.54% 905 27.16% 72.84% 30.19% 39.96% 2.68%
841 28.75% 71.25% 29.61% 39.11% 2.54% 906 27.13% 72.87% 30.20% 39.98% 2.69%
842 28.72% 71.28% 29.62% 39.11% 2.54% 907 27.10% 72.90% 30.21% 40.00% 2.69%
843 28.71% 71.30% 29.63% 39.12% 2.54% 908 27.08% 72.92% 30.22% 40.01% 2.69%
844 28.68% 71.32% 29.63% 39.14% 2.55% 909 27.06% 72.94% 30.22% 40.03% 2.69%
845 28.66% 71.34% 29.64% 39.15% 2.55% 910 27.04% 72.96% 30.23% 40.04% 2.69%
846 28.63% 71.37% 29.65% 39.16% 2.55% 911 27.02% 72.98% 30.24% 40.05% 2.69%
847 28.61% 71.39% 29.66% 39.17% 2.55% 912 27.00% 73.00% 30.24% 40.07% 2.69%
848 28.58% 71.42% 29.67% 39.19% 2.56% 913 26.97% 73.03% 30.25% 40.08% 2.69%
849 28.55% 71.45% 29.68% 39.21% 2.56% 914 26.95% 73.05% 30.26% 40.09% 2.70%
850 28.52% 71.48% 29.69% 39.23% 2.56% 915 26.93% 73.07% 30.27% 40.11% 2.70%
851 28.50% 71.50% 29.70% 39.24% 2.56% 916 26.91% 73.09% 30.27% 40.12% 2.70%
852 28.47% 71.53% 29.70% 39.26% 2.57% 917 26.89% 73.11% 30.28% 40.13% 2.71%
853 28.45% 71.55% 29.71% 39.27% 2.57% 918 26.86% 73.14% 30.29% 40.14% 2.71%
854 28.43% 71.57% 29.72% 39.28% 2.57% 919 26.83% 73.17% 30.30% 40.16% 2.71%
855 28.41% 71.59% 29.73% 39.29% 2.57% 920 26.81% 73.20% 30.31% 40.18% 2.71%
856 28.39% 71.61% 29.74% 39.30% 2.57% 921 26.79% 73.21% 30.31% 40.19% 2.71%
857 28.36% 71.64% 29.74% 39.33% 2.58% 922 26.76% 73.24% 30.32% 40.21% 2.71%
858 28.33% 71.67% 29.75% 39.34% 2.58% 923 26.74% 73.26% 30.33% 40.22% 2.71%
859 28.30% 71.70% 29.76% 39.36% 2.58% 924 26.72% 73.28% 30.34% 40.23% 2.72%
860 28.27% 71.73% 29.77% 39.38% 2.59% 925 26.69% 73.31% 30.35% 40.24% 2.72%
861 28.25% 71.75% 29.78% 39.39% 2.59% 926 26.67% 73.33% 30.36% 40.25% 2.72%
862 28.23% 71.77% 29.78% 39.40% 2.59% 927 26.65% 73.35% 30.37% 40.26% 2.72%
863 28.20% 71.80% 29.79% 39.42% 2.59% 928 26.63% 73.37% 30.37% 40.28% 2.72%
215
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 929 26.60% 73.40% 30.38% 40.29% 2.72% 994 25.25% 74.75% 30.84% 41.07% 2.85%
930 26.57% 73.43% 30.39% 40.31% 2.73% 995 25.23% 74.77% 30.85% 41.08% 2.85%
931 26.56% 73.44% 30.40% 40.31% 2.73% 996 25.21% 74.79% 30.86% 41.09% 2.85%
932 26.53% 73.47% 30.40% 40.33% 2.73% 997 25.19% 74.81% 30.86% 41.10% 2.85%
933 26.50% 73.50% 30.42% 40.34% 2.74% 998 25.18% 74.82% 30.87% 41.11% 2.85%
934 26.48% 73.52% 30.43% 40.36% 2.74% 999 25.15% 74.85% 30.88% 41.11% 2.85%
935 26.45% 73.55% 30.44% 40.37% 2.74% 1000 25.13% 74.87% 30.89% 41.13% 2.85%
936 26.43% 73.57% 30.45% 40.38% 2.74% 1001 25.11% 74.89% 30.90% 41.14% 2.85%
937 26.40% 73.60% 30.46% 40.40% 2.74% 1002 25.10% 74.90% 30.90% 41.14% 2.86%
938 26.38% 73.62% 30.46% 40.41% 2.74% 1003 25.08% 74.92% 30.92% 41.15% 2.86%
939 26.35% 73.65% 30.47% 40.43% 2.75% 1004 25.05% 74.95% 30.93% 41.16% 2.86%
940 26.33% 73.67% 30.48% 40.44% 2.75% 1005 25.04% 74.96% 30.93% 41.17% 2.86%
941 26.31% 73.69% 30.48% 40.46% 2.75% 1006 25.01% 74.99% 30.95% 41.18% 2.86%
942 26.28% 73.72% 30.49% 40.48% 2.75% 1007 24.99% 75.01% 30.95% 41.19% 2.87%
943 26.27% 73.73% 30.50% 40.49% 2.75% 1008 24.97% 75.03% 30.96% 41.20% 2.87%
944 26.25% 73.75% 30.50% 40.49% 2.75% 1009 24.95% 75.05% 30.97% 41.21% 2.87%
945 26.24% 73.76% 30.51% 40.50% 2.76% 1010 24.94% 75.06% 30.97% 41.22% 2.87%
946 26.22% 73.78% 30.52% 40.51% 2.76% 1011 24.92% 75.08% 30.98% 41.23% 2.87%
947 26.20% 73.80% 30.53% 40.52% 2.76% 1012 24.90% 75.10% 30.99% 41.24% 2.88%
948 26.17% 73.83% 30.53% 40.54% 2.76% 1013 24.88% 75.12% 31.00% 41.25% 2.88%
949 26.15% 73.85% 30.54% 40.55% 2.76% 1014 24.87% 75.13% 31.00% 41.25% 2.88%
950 26.13% 73.87% 30.55% 40.56% 2.76% 1015 24.84% 75.16% 31.01% 41.27% 2.88%
951 26.11% 73.89% 30.56% 40.57% 2.76% 1016 24.83% 75.17% 31.02% 41.27% 2.88%
952 26.08% 73.92% 30.56% 40.59% 2.77% 1017 24.81% 75.19% 31.02% 41.28% 2.88%
953 26.06% 73.94% 30.57% 40.60% 2.77% 1018 24.79% 75.21% 31.04% 41.29% 2.89%
954 26.04% 73.96% 30.58% 40.61% 2.77% 1019 24.77% 75.23% 31.04% 41.30% 2.89%
955 26.01% 73.99% 30.59% 40.63% 2.77% 1020 24.76% 75.24% 31.05% 41.30% 2.89%
956 25.98% 74.02% 30.60% 40.65% 2.77% 1021 24.74% 75.26% 31.06% 41.31% 2.89%
957 25.95% 74.05% 30.61% 40.66% 2.78% 1022 24.72% 75.28% 31.07% 41.32% 2.90%
958 25.94% 74.06% 30.61% 40.67% 2.78% 1023 24.71% 75.29% 31.07% 41.33% 2.90%
959 25.92% 74.08% 30.62% 40.68% 2.78% 1024 24.69% 75.31% 31.08% 41.34% 2.90%
960 25.91% 74.09% 30.62% 40.69% 2.78% 1025 24.67% 75.33% 31.09% 41.35% 2.90%
961 25.89% 74.11% 30.63% 40.70% 2.78% 1026 24.66% 75.34% 31.09% 41.35% 2.90%
962 25.87% 74.13% 30.63% 40.71% 2.78% 1027 24.64% 75.36% 31.10% 41.36% 2.90%
963 25.86% 74.15% 30.64% 40.72% 2.78% 1028 24.62% 75.38% 31.10% 41.37% 2.91%
964 25.84% 74.16% 30.65% 40.73% 2.78% 1029 24.59% 75.41% 31.12% 41.38% 2.91%
965 25.81% 74.19% 30.66% 40.75% 2.79% 1030 24.57% 75.43% 31.12% 41.39% 2.91%
966 25.79% 74.21% 30.67% 40.75% 2.79% 1031 24.56% 75.44% 31.13% 41.41% 2.91%
967 25.77% 74.23% 30.68% 40.76% 2.79% 1032 24.54% 75.46% 31.13% 41.42% 2.91%
968 25.76% 74.24% 30.68% 40.77% 2.79% 1033 24.52% 75.48% 31.14% 41.43% 2.91%
969 25.73% 74.27% 30.69% 40.79% 2.79% 1034 24.50% 75.50% 31.15% 41.44% 2.92%
970 25.71% 74.30% 30.70% 40.80% 2.80% 1035 24.48% 75.52% 31.15% 41.45% 2.92%
971 25.68% 74.32% 30.70% 40.82% 2.80% 1036 24.46% 75.54% 31.16% 41.47% 2.92%
972 25.67% 74.33% 30.71% 40.83% 2.80% 1037 24.44% 75.56% 31.16% 41.48% 2.92%
973 25.65% 74.36% 30.71% 40.84% 2.80% 1038 24.42% 75.58% 31.17% 41.49% 2.92%
974 25.62% 74.38% 30.72% 40.85% 2.81% 1039 24.40% 75.60% 31.18% 41.50% 2.92%
975 25.60% 74.40% 30.73% 40.86% 2.81% 1040 24.39% 75.61% 31.18% 41.51% 2.92%
976 25.59% 74.42% 30.73% 40.87% 2.81% 1041 24.36% 75.64% 31.19% 41.52% 2.93%
977 25.57% 74.43% 30.73% 40.88% 2.81% 1042 24.33% 75.67% 31.20% 41.54% 2.93%
978 25.56% 74.44% 30.74% 40.89% 2.82% 1043 24.32% 75.69% 31.21% 41.55% 2.93%
979 25.54% 74.46% 30.75% 40.90% 2.82% 1044 24.30% 75.70% 31.21% 41.55% 2.93%
980 25.52% 74.48% 30.75% 40.91% 2.82% 1045 24.28% 75.72% 31.22% 41.56% 2.94%
981 25.50% 74.50% 30.76% 40.92% 2.82% 1046 24.27% 75.73% 31.22% 41.57% 2.94%
982 25.49% 74.51% 30.76% 40.93% 2.82% 1047 24.25% 75.75% 31.23% 41.59% 2.94%
983 25.47% 74.53% 30.77% 40.94% 2.83% 1048 24.22% 75.78% 31.24% 41.60% 2.94%
984 25.44% 74.56% 30.77% 40.96% 2.83% 1049 24.20% 75.80% 31.24% 41.62% 2.94%
985 25.42% 74.58% 30.78% 40.97% 2.83% 1050 24.18% 75.82% 31.25% 41.63% 2.94%
986 25.40% 74.60% 30.79% 40.99% 2.83% 1051 24.17% 75.84% 31.26% 41.64% 2.94%
987 25.38% 74.62% 30.79% 41.00% 2.83% 1052 24.15% 75.85% 31.27% 41.65% 2.94%
988 25.36% 74.64% 30.80% 41.01% 2.83% 1053 24.13% 75.87% 31.28% 41.66% 2.94%
989 25.35% 74.65% 30.81% 41.01% 2.83% 1054 24.11% 75.89% 31.28% 41.66% 2.95%
990 25.33% 74.67% 30.81% 41.02% 2.84% 1055 24.09% 75.91% 31.29% 41.67% 2.95%
991 25.30% 74.70% 30.83% 41.04% 2.84% 1056 24.08% 75.92% 31.30% 41.68% 2.95%
992 25.28% 74.72% 30.83% 41.05% 2.84% 1057 24.05% 75.95% 31.30% 41.70% 2.95%
993 25.26% 74.74% 30.84% 41.06% 2.84% 1058 24.04% 75.96% 31.31% 41.71% 2.95%
216
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 1059 24.02% 75.99% 31.32% 41.72% 2.95% 1124 22.91% 77.09% 31.74% 42.31% 3.04%
1060 24.00% 76.00% 31.32% 41.73% 2.95% 1125 22.89% 77.11% 31.75% 42.32% 3.05%
1061 23.98% 76.02% 31.33% 41.74% 2.95% 1126 22.87% 77.13% 31.75% 42.33% 3.05%
1062 23.96% 76.04% 31.34% 41.74% 2.95% 1127 22.86% 77.14% 31.76% 42.34% 3.05%
1063 23.95% 76.06% 31.35% 41.75% 2.96% 1128 22.84% 77.16% 31.76% 42.35% 3.05%
1064 23.93% 76.07% 31.35% 41.76% 2.96% 1129 22.83% 77.18% 31.77% 42.36% 3.05%
1065 23.92% 76.09% 31.36% 41.77% 2.96% 1130 22.81% 77.19% 31.77% 42.37% 3.05%
1066 23.90% 76.10% 31.36% 41.78% 2.96% 1131 22.80% 77.20% 31.78% 42.37% 3.05%
1067 23.88% 76.12% 31.37% 41.79% 2.96% 1132 22.78% 77.22% 31.78% 42.38% 3.06%
1068 23.87% 76.13% 31.38% 41.80% 2.96% 1133 22.77% 77.24% 31.79% 42.39% 3.06%
1069 23.85% 76.15% 31.38% 41.81% 2.96% 1134 22.75% 77.25% 31.79% 42.40% 3.06%
1070 23.84% 76.16% 31.39% 41.81% 2.96% 1135 22.73% 77.27% 31.80% 42.41% 3.06%
1071 23.82% 76.18% 31.39% 41.83% 2.96% 1136 22.71% 77.29% 31.81% 42.42% 3.07%
1072 23.81% 76.20% 31.39% 41.84% 2.97% 1137 22.70% 77.30% 31.81% 42.42% 3.07%
1073 23.78% 76.22% 31.40% 41.85% 2.97% 1138 22.69% 77.32% 31.82% 42.43% 3.07%
1074 23.77% 76.23% 31.41% 41.86% 2.97% 1139 22.67% 77.33% 31.82% 42.44% 3.07%
1075 23.74% 76.26% 31.41% 41.88% 2.97% 1140 22.66% 77.34% 31.83% 42.45% 3.07%
1076 23.73% 76.28% 31.42% 41.88% 2.97% 1141 22.63% 77.37% 31.83% 42.46% 3.07%
1077 23.70% 76.30% 31.43% 41.90% 2.98% 1142 22.62% 77.38% 31.84% 42.47% 3.07%
1078 23.68% 76.32% 31.44% 41.90% 2.98% 1143 22.61% 77.39% 31.85% 42.47% 3.07%
1079 23.67% 76.33% 31.44% 41.91% 2.98% 1144 22.59% 77.42% 31.86% 42.49% 3.07%
1080 23.64% 76.36% 31.45% 41.92% 2.99% 1145 22.57% 77.43% 31.86% 42.50% 3.08%
1081 23.63% 76.37% 31.46% 41.93% 2.99% 1146 22.55% 77.45% 31.87% 42.50% 3.08%
1082 23.61% 76.39% 31.46% 41.94% 2.99% 1147 22.54% 77.46% 31.87% 42.51% 3.08%
1083 23.60% 76.40% 31.46% 41.95% 2.99% 1148 22.52% 77.48% 31.88% 42.52% 3.08%
1084 23.58% 76.42% 31.47% 41.96% 2.99% 1149 22.50% 77.50% 31.89% 42.53% 3.08%
1085 23.56% 76.44% 31.48% 41.97% 2.99% 1150 22.49% 77.51% 31.89% 42.54% 3.08%
1086 23.54% 76.46% 31.48% 41.98% 3.00% 1151 22.48% 77.52% 31.89% 42.54% 3.08%
1087 23.53% 76.48% 31.49% 41.99% 3.00% 1152 22.47% 77.54% 31.90% 42.55% 3.09%
1088 23.51% 76.50% 31.50% 42.00% 3.00% 1153 22.45% 77.55% 31.90% 42.56% 3.09%
1089 23.49% 76.51% 31.51% 42.00% 3.00% 1154 22.44% 77.56% 31.91% 42.56% 3.09%
1090 23.48% 76.52% 31.52% 42.01% 3.00% 1155 22.43% 77.57% 31.91% 42.57% 3.09%
1091 23.46% 76.54% 31.52% 42.02% 3.00% 1156 22.42% 77.58% 31.92% 42.58% 3.09%
1092 23.45% 76.55% 31.52% 42.03% 3.00% 1157 22.40% 77.60% 31.92% 42.59% 3.09%
1093 23.44% 76.56% 31.53% 42.03% 3.00% 1158 22.38% 77.62% 31.93% 42.60% 3.10%
1094 23.42% 76.58% 31.54% 42.04% 3.00% 1159 22.37% 77.63% 31.93% 42.60% 3.10%
1095 23.40% 76.60% 31.55% 42.05% 3.00% 1160 22.36% 77.65% 31.94% 42.61% 3.10%
1096 23.39% 76.62% 31.55% 42.06% 3.01% 1161 22.34% 77.66% 31.94% 42.62% 3.10%
1097 23.37% 76.63% 31.55% 42.07% 3.01% 1162 22.33% 77.67% 31.94% 42.62% 3.10%
1098 23.36% 76.65% 31.56% 42.07% 3.01% 1163 22.32% 77.68% 31.95% 42.63% 3.10%
1099 23.34% 76.66% 31.57% 42.08% 3.01% 1164 22.30% 77.70% 31.96% 42.64% 3.11%
1100 23.32% 76.68% 31.57% 42.09% 3.01% 1165 22.29% 77.71% 31.96% 42.64% 3.11%
1101 23.31% 76.69% 31.58% 42.10% 3.01% 1166 22.28% 77.72% 31.96% 42.65% 3.11%
1102 23.29% 76.71% 31.59% 42.11% 3.01% 1167 22.26% 77.74% 31.97% 42.66% 3.11%
1103 23.28% 76.72% 31.59% 42.12% 3.01% 1168 22.24% 77.76% 31.97% 42.67% 3.11%
1104 23.25% 76.75% 31.60% 42.13% 3.02% 1169 22.24% 77.76% 31.98% 42.67% 3.11%
1105 23.23% 76.77% 31.60% 42.14% 3.02% 1170 22.23% 77.77% 31.98% 42.68% 3.11%
1106 23.22% 76.78% 31.61% 42.15% 3.02% 1171 22.21% 77.79% 31.98% 42.69% 3.12%
1107 23.21% 76.79% 31.62% 42.16% 3.02% 1172 22.20% 77.80% 31.99% 42.70% 3.12%
1108 23.18% 76.82% 31.63% 42.17% 3.02% 1173 22.18% 77.82% 32.00% 42.71% 3.12%
1109 23.16% 76.84% 31.64% 42.17% 3.03% 1174 22.17% 77.83% 32.00% 42.71% 3.12%
1110 23.15% 76.85% 31.65% 42.18% 3.03% 1175 22.16% 77.84% 32.01% 42.72% 3.12%
1111 23.13% 76.87% 31.65% 42.19% 3.03% 1176 22.15% 77.85% 32.01% 42.72% 3.12%
1112 23.11% 76.89% 31.66% 42.20% 3.03% 1177 22.14% 77.86% 32.02% 42.72% 3.12%
1113 23.10% 76.91% 31.66% 42.22% 3.03% 1178 22.13% 77.88% 32.02% 42.73% 3.12%
1114 23.08% 76.92% 31.67% 42.22% 3.03% 1179 22.11% 77.89% 32.03% 42.74% 3.12%
1115 23.07% 76.93% 31.67% 42.23% 3.03% 1180 22.10% 77.90% 32.03% 42.75% 3.12%
1116 23.05% 76.95% 31.68% 42.24% 3.04% 1181 22.08% 77.92% 32.04% 42.76% 3.12%
1117 23.03% 76.97% 31.69% 42.24% 3.04% 1182 22.07% 77.93% 32.04% 42.77% 3.12%
1118 23.01% 76.99% 31.70% 42.25% 3.04% 1183 22.04% 77.96% 32.05% 42.79% 3.13%
1119 22.99% 77.01% 31.71% 42.26% 3.04% 1184 22.03% 77.97% 32.05% 42.79% 3.13%
1120 22.98% 77.02% 31.71% 42.27% 3.04% 1185 22.02% 77.98% 32.06% 42.80% 3.13%
1121 22.97% 77.04% 31.72% 42.28% 3.04% 1186 22.00% 78.00% 32.07% 42.80% 3.13%
1122 22.95% 77.05% 31.73% 42.29% 3.04% 1187 21.99% 78.01% 32.07% 42.81% 3.13%
1123 22.93% 77.08% 31.73% 42.30% 3.04% 1188 21.97% 78.03% 32.08% 42.82% 3.13%
217
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 1189 21.95% 78.05% 32.09% 42.83% 3.13%
1190 21.94% 78.06% 32.09% 42.84% 3.13%
1191 21.93% 78.07% 32.10% 42.84% 3.13%
1192 21.92% 78.09% 32.11% 42.84% 3.14%
1193 21.89% 78.11% 32.11% 42.86% 3.14%
1194 21.87% 78.13% 32.13% 42.87% 3.14%
1195 21.85% 78.15% 32.13% 42.88% 3.14%
1196 21.83% 78.17% 32.14% 42.89% 3.14%
1197 21.82% 78.19% 32.15% 42.90% 3.14%
1198 21.80% 78.21% 32.15% 42.91% 3.14%
1199 21.78% 78.23% 32.16% 42.92% 3.14%
1200 21.76% 78.24% 32.17% 42.93% 3.15%
218
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA
-306 97.45% 2.55% 0.86% 1.66% 0.00%
-305 97.44% 2.56% 0.87% 1.67% 0.00%
Table B7. LOCA Probability History for ASP-06 -304 97.43% 2.57% 0.87% 1.68% 0.00%
for Days After TOD -303 97.41% 2.59% 0.87% 1.69% 0.00%
-302 97.40% 2.60% 0.88% 1.70% 0.00%
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA -301 97.39% 2.61% 0.88% 1.71% 0.00%
-365 98.21% 1.79% 0.63% 1.14% 0.00% -300 97.38% 2.62% 0.89% 1.71% 0.00%
-364 98.20% 1.80% 0.63% 1.15% 0.00% -299 97.36% 2.64% 0.89% 1.73% 0.00%
-363 98.19% 1.81% 0.64% 1.16% 0.00% -298 97.34% 2.66% 0.90% 1.74% 0.00%
-362 98.18% 1.82% 0.65% 1.16% 0.00% -297 97.32% 2.68% 0.90% 1.75% 0.00%
-361 98.17% 1.83% 0.65% 1.17% 0.00% -296 97.31% 2.69% 0.91% 1.76% 0.00%
-360 98.16% 1.84% 0.65% 1.18% 0.00% -295 97.30% 2.71% 0.91% 1.77% 0.00%
-359 98.15% 1.85% 0.65% 1.19% 0.00% -294 97.28% 2.72% 0.91% 1.79% 0.00%
-358 98.13% 1.87% 0.66% 1.20% 0.00% -293 97.26% 2.74% 0.92% 1.80% 0.00%
-357 98.12% 1.88% 0.66% 1.20% 0.00% -292 97.23% 2.77% 0.92% 1.82% 0.00%
-356 98.11% 1.89% 0.66% 1.21% 0.00% -291 97.21% 2.79% 0.93% 1.83% 0.00%
-355 98.10% 1.90% 0.66% 1.22% 0.00% -290 97.20% 2.80% 0.94% 1.84% 0.00%
-354 98.09% 1.91% 0.67% 1.23% 0.00% -289 97.18% 2.83% 0.94% 1.86% 0.00%
-353 98.08% 1.92% 0.67% 1.24% 0.00% -288 97.16% 2.85% 0.95% 1.87% 0.00%
-352 98.07% 1.93% 0.67% 1.24% 0.00% -287 97.14% 2.87% 0.96% 1.88% 0.00%
-351 98.06% 1.94% 0.67% 1.25% 0.00% -286 97.11% 2.89% 0.97% 1.90% 0.00%
-350 98.06% 1.94% 0.67% 1.25% 0.00% -285 97.09% 2.91% 0.97% 1.92% 0.00%
-349 98.05% 1.95% 0.68% 1.26% 0.00% -284 97.07% 2.93% 0.98% 1.93% 0.00%
-348 98.04% 1.96% 0.68% 1.27% 0.00% -283 97.05% 2.95% 0.98% 1.94% 0.00%
-347 98.02% 1.98% 0.68% 1.28% 0.00% -282 97.04% 2.97% 0.99% 1.95% 0.00%
-346 98.02% 1.98% 0.69% 1.28% 0.00% -281 97.02% 2.98% 1.00% 1.96% 0.00%
-345 98.00% 2.00% 0.69% 1.29% 0.00% -280 97.01% 2.99% 1.00% 1.97% 0.00%
-344 97.99% 2.01% 0.69% 1.30% 0.00% -279 96.98% 3.02% 1.00% 1.99% 0.00%
-343 97.98% 2.02% 0.70% 1.31% 0.00% -278 96.97% 3.03% 1.01% 2.00% 0.00%
-342 97.97% 2.03% 0.70% 1.31% 0.00% -277 96.95% 3.05% 1.01% 2.02% 0.00%
-341 97.95% 2.05% 0.71% 1.32% 0.00% -276 96.93% 3.07% 1.02% 2.03% 0.00%
-340 97.94% 2.06% 0.71% 1.33% 0.00% -275 96.90% 3.10% 1.02% 2.05% 0.00%
-339 97.93% 2.07% 0.72% 1.34% 0.00% -274 96.88% 3.12% 1.03% 2.06% 0.00%
-338 97.91% 2.09% 0.72% 1.35% 0.00% -273 96.87% 3.13% 1.03% 2.08% 0.00%
-337 97.90% 2.10% 0.72% 1.36% 0.00% -272 96.85% 3.15% 1.03% 2.09% 0.00%
-336 97.88% 2.12% 0.73% 1.37% 0.00% -271 96.84% 3.17% 1.04% 2.10% 0.00%
-335 97.87% 2.13% 0.73% 1.38% 0.00% -270 96.81% 3.20% 1.04% 2.13% 0.00%
-334 97.86% 2.14% 0.74% 1.38% 0.00% -269 96.79% 3.22% 1.05% 2.14% 0.00%
-333 97.85% 2.15% 0.74% 1.39% 0.00% -268 96.76% 3.24% 1.05% 2.16% 0.00%
-332 97.84% 2.17% 0.75% 1.40% 0.00% -267 96.74% 3.26% 1.06% 2.18% 0.00%
-331 97.83% 2.18% 0.75% 1.41% 0.00% -266 96.72% 3.28% 1.07% 2.19% 0.00%
-330 97.81% 2.19% 0.75% 1.42% 0.00% -265 96.70% 3.30% 1.07% 2.20% 0.00%
-329 97.80% 2.20% 0.76% 1.43% 0.00% -264 96.68% 3.32% 1.08% 2.21% 0.00%
-328 97.79% 2.21% 0.76% 1.43% 0.00% -263 96.66% 3.34% 1.08% 2.23% 0.00%
-327 97.78% 2.22% 0.76% 1.44% 0.00% -262 96.64% 3.36% 1.09% 2.25% 0.00%
-326 97.77% 2.23% 0.76% 1.45% 0.00% -261 96.62% 3.38% 1.10% 2.26% 0.00%
-325 97.75% 2.25% 0.77% 1.46% 0.00% -260 96.60% 3.40% 1.10% 2.27% 0.00%
-324 97.74% 2.26% 0.77% 1.47% 0.00% -259 96.58% 3.42% 1.10% 2.28% 0.00%
-323 97.72% 2.28% 0.77% 1.48% 0.00% -258 96.57% 3.43% 1.11% 2.30% 0.00%
-322 97.70% 2.30% 0.78% 1.50% 0.00% -257 96.54% 3.46% 1.12% 2.31% 0.00%
-321 97.68% 2.32% 0.79% 1.51% 0.00% -256 96.52% 3.48% 1.12% 2.33% 0.00%
-320 97.67% 2.33% 0.79% 1.52% 0.00% -255 96.50% 3.50% 1.13% 2.34% 0.00%
-319 97.65% 2.36% 0.80% 1.53% 0.00% -254 96.48% 3.52% 1.14% 2.36% 0.00%
-318 97.63% 2.38% 0.81% 1.55% 0.00% -253 96.45% 3.55% 1.14% 2.38% 0.00%
-317 97.62% 2.39% 0.81% 1.55% 0.00% -252 96.43% 3.57% 1.15% 2.39% 0.00%
-316 97.60% 2.40% 0.81% 1.56% 0.00% -251 96.41% 3.60% 1.16% 2.41% 0.00%
-315 97.59% 2.41% 0.82% 1.57% 0.00% -250 96.38% 3.62% 1.16% 2.43% 0.00%
-314 97.58% 2.43% 0.82% 1.58% 0.00% -249 96.37% 3.63% 1.17% 2.44% 0.00%
-313 97.56% 2.44% 0.83% 1.59% 0.00% -248 96.35% 3.65% 1.17% 2.45% 0.00%
-312 97.54% 2.46% 0.83% 1.60% 0.00% -247 96.33% 3.67% 1.18% 2.46% 0.00%
-311 97.53% 2.47% 0.84% 1.61% 0.00% -246 96.31% 3.69% 1.19% 2.48% 0.00%
-310 97.51% 2.49% 0.84% 1.62% 0.00% -245 96.29% 3.72% 1.19% 2.50% 0.00%
-309 97.49% 2.51% 0.85% 1.63% 0.00% -244 96.27% 3.73% 1.19% 2.51% 0.00%
-308 97.48% 2.52% 0.85% 1.65% 0.00% -243 96.24% 3.76% 1.20% 2.53% 0.00%
-307 97.46% 2.54% 0.86% 1.65% 0.00% -242 96.22% 3.78% 1.21% 2.54% 0.00%
219
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA
-241 96.20% 3.80% 1.22% 2.56% 0.00% -176 94.13% 5.87% 1.72% 4.09% 0.02%
-240 96.19% 3.82% 1.22% 2.57% 0.00% -175 94.09% 5.91% 1.73% 4.13% 0.02%
-239 96.16% 3.84% 1.22% 2.59% 0.00% -174 94.04% 5.96% 1.74% 4.16% 0.02%
-238 96.14% 3.86% 1.23% 2.60% 0.00% -173 94.00% 6.00% 1.74% 4.20% 0.02%
-237 96.11% 3.89% 1.23% 2.62% 0.00% -172 93.95% 6.05% 1.76% 4.23% 0.02%
-236 96.08% 3.92% 1.24% 2.65% 0.00% -171 93.90% 6.10% 1.77% 4.27% 0.02%
-235 96.06% 3.95% 1.25% 2.66% 0.00% -170 93.86% 6.14% 1.77% 4.30% 0.02%
-234 96.03% 3.97% 1.26% 2.68% 0.00% -169 93.82% 6.18% 1.78% 4.33% 0.02%
-233 96.00% 4.00% 1.27% 2.71% 0.00% -168 93.78% 6.22% 1.80% 4.36% 0.02%
-232 95.96% 4.05% 1.28% 2.74% 0.00% -167 93.72% 6.28% 1.81% 4.41% 0.02%
-231 95.93% 4.07% 1.29% 2.75% 0.00% -166 93.68% 6.32% 1.82% 4.43% 0.02%
-230 95.91% 4.09% 1.29% 2.77% 0.00% -165 93.64% 6.37% 1.83% 4.47% 0.02%
-229 95.88% 4.12% 1.29% 2.79% 0.00% -164 93.59% 6.41% 1.84% 4.50% 0.02%
-228 95.85% 4.15% 1.30% 2.81% 0.00% -163 93.56% 6.44% 1.84% 4.53% 0.02%
-227 95.83% 4.17% 1.31% 2.83% 0.00% -162 93.52% 6.48% 1.85% 4.57% 0.02%
-226 95.80% 4.20% 1.32% 2.85% 0.00% -161 93.48% 6.52% 1.86% 4.59% 0.02%
-225 95.78% 4.23% 1.32% 2.87% 0.00% -160 93.44% 6.56% 1.86% 4.63% 0.02%
-224 95.74% 4.26% 1.33% 2.89% 0.00% -159 93.40% 6.60% 1.87% 4.66% 0.02%
-223 95.72% 4.28% 1.34% 2.91% 0.00% -158 93.36% 6.64% 1.88% 4.69% 0.02%
-222 95.69% 4.31% 1.35% 2.93% 0.00% -157 93.31% 6.69% 1.89% 4.73% 0.02%
-221 95.66% 4.34% 1.35% 2.95% 0.00% -156 93.28% 6.72% 1.90% 4.76% 0.02%
-220 95.63% 4.37% 1.36% 2.97% 0.00% -155 93.24% 6.76% 1.90% 4.78% 0.02%
-219 95.60% 4.41% 1.37% 3.00% 0.00% -154 93.20% 6.80% 1.91% 4.81% 0.02%
-218 95.57% 4.43% 1.38% 3.02% 0.00% -153 93.17% 6.83% 1.92% 4.84% 0.02%
-217 95.53% 4.47% 1.38% 3.05% 0.00% -152 93.13% 6.87% 1.92% 4.87% 0.02%
-216 95.50% 4.50% 1.39% 3.08% 0.00% -151 93.08% 6.92% 1.94% 4.91% 0.03%
-215 95.47% 4.53% 1.39% 3.10% 0.00% -150 93.04% 6.96% 1.94% 4.94% 0.03%
-214 95.44% 4.57% 1.40% 3.13% 0.00% -149 93.00% 7.00% 1.95% 4.97% 0.03%
-213 95.41% 4.59% 1.41% 3.14% 0.00% -148 92.95% 7.05% 1.97% 5.01% 0.03%
-212 95.37% 4.63% 1.42% 3.17% 0.00% -147 92.90% 7.10% 1.98% 5.05% 0.03%
-211 95.34% 4.66% 1.43% 3.19% 0.00% -146 92.87% 7.13% 1.98% 5.07% 0.03%
-210 95.31% 4.69% 1.44% 3.21% 0.00% -145 92.83% 7.18% 1.99% 5.10% 0.03%
-209 95.27% 4.73% 1.45% 3.24% 0.00% -144 92.78% 7.23% 2.00% 5.14% 0.03%
-208 95.26% 4.74% 1.45% 3.25% 0.00% -143 92.73% 7.27% 2.01% 5.17% 0.03%
-207 95.22% 4.78% 1.46% 3.28% 0.00% -142 92.68% 7.32% 2.03% 5.21% 0.03%
-206 95.18% 4.82% 1.48% 3.30% 0.00% -141 92.64% 7.36% 2.03% 5.25% 0.03%
-205 95.15% 4.85% 1.48% 3.33% 0.00% -140 92.59% 7.41% 2.04% 5.28% 0.03%
-204 95.11% 4.89% 1.50% 3.35% 0.00% -139 92.54% 7.46% 2.06% 5.32% 0.03%
-203 95.08% 4.92% 1.50% 3.38% 0.00% -138 92.48% 7.52% 2.06% 5.37% 0.03%
-202 95.04% 4.96% 1.51% 3.41% 0.00% -137 92.43% 7.57% 2.08% 5.41% 0.03%
-201 95.01% 4.99% 1.52% 3.43% 0.00% -136 92.38% 7.62% 2.09% 5.45% 0.03%
-200 94.98% 5.02% 1.52% 3.45% 0.00% -135 92.32% 7.68% 2.10% 5.49% 0.03%
-199 94.95% 5.05% 1.53% 3.48% 0.00% -134 92.27% 7.73% 2.12% 5.53% 0.04%
-198 94.91% 5.09% 1.54% 3.50% 0.01% -133 92.21% 7.79% 2.13% 5.57% 0.04%
-197 94.87% 5.13% 1.55% 3.54% 0.01% -132 92.15% 7.85% 2.15% 5.61% 0.04%
-196 94.83% 5.17% 1.56% 3.57% 0.01% -131 92.11% 7.89% 2.16% 5.65% 0.04%
-195 94.79% 5.21% 1.57% 3.59% 0.01% -130 92.07% 7.94% 2.16% 5.68% 0.04%
-194 94.77% 5.24% 1.57% 3.62% 0.01% -129 92.01% 7.99% 2.17% 5.72% 0.04%
-193 94.73% 5.27% 1.58% 3.64% 0.01% -128 91.97% 8.04% 2.18% 5.76% 0.04%
-192 94.70% 5.30% 1.59% 3.66% 0.01% -127 91.91% 8.09% 2.19% 5.80% 0.05%
-191 94.67% 5.33% 1.60% 3.69% 0.01% -126 91.85% 8.15% 2.20% 5.85% 0.05%
-190 94.63% 5.37% 1.61% 3.71% 0.01% -125 91.80% 8.20% 2.21% 5.89% 0.05%
-189 94.61% 5.40% 1.61% 3.74% 0.01% -124 91.74% 8.26% 2.23% 5.93% 0.05%
-188 94.56% 5.44% 1.62% 3.77% 0.01% -123 91.67% 8.33% 2.23% 5.99% 0.05%
-187 94.53% 5.47% 1.63% 3.79% 0.01% -122 91.63% 8.37% 2.25% 6.02% 0.05%
-186 94.49% 5.51% 1.63% 3.83% 0.01% -121 91.58% 8.43% 2.26% 6.07% 0.05%
-185 94.46% 5.54% 1.64% 3.85% 0.01% -120 91.52% 8.48% 2.26% 6.11% 0.05%
-184 94.43% 5.57% 1.65% 3.87% 0.01% -119 91.46% 8.54% 2.28% 6.16% 0.05%
-183 94.39% 5.61% 1.66% 3.90% 0.01% -118 91.40% 8.60% 2.29% 6.20% 0.05%
-182 94.36% 5.64% 1.66% 3.92% 0.01% -117 91.35% 8.65% 2.30% 6.24% 0.06%
-181 94.32% 5.68% 1.67% 3.95% 0.01% -116 91.28% 8.72% 2.31% 6.29% 0.06%
-180 94.29% 5.71% 1.68% 3.98% 0.01% -115 91.22% 8.78% 2.33% 6.33% 0.06%
-179 94.25% 5.75% 1.69% 4.00% 0.01% -114 91.17% 8.83% 2.34% 6.37% 0.06%
-178 94.21% 5.79% 1.70% 4.04% 0.01% -113 91.12% 8.88% 2.35% 6.42% 0.06%
-177 94.17% 5.83% 1.71% 4.07% 0.01% -112 91.07% 8.93% 2.36% 6.46% 0.06%
220
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA
-111 91.00% 9.00% 2.38% 6.50% 0.07% -46 86.46% 13.55% 3.21% 9.97% 0.30%
-110 90.96% 9.05% 2.39% 6.53% 0.07% -45 86.38% 13.62% 3.23% 10.03% 0.31%
-109 90.90% 9.10% 2.40% 6.58% 0.07% -44 86.31% 13.69% 3.23% 10.09% 0.31%
-108 90.85% 9.15% 2.41% 6.62% 0.07% -43 86.22% 13.78% 3.24% 10.16% 0.32%
-107 90.79% 9.21% 2.42% 6.66% 0.07% -42 86.13% 13.87% 3.26% 10.22% 0.33%
-106 90.73% 9.27% 2.43% 6.71% 0.08% -41 86.05% 13.95% 3.27% 10.28% 0.34%
-105 90.66% 9.34% 2.44% 6.76% 0.08% -40 85.96% 14.04% 3.29% 10.35% 0.34%
-104 90.61% 9.39% 2.46% 6.80% 0.08% -39 85.87% 14.13% 3.30% 10.42% 0.35%
-103 90.55% 9.45% 2.46% 6.85% 0.08% -38 85.78% 14.22% 3.32% 10.49% 0.35%
-102 90.51% 9.50% 2.47% 6.89% 0.08% -37 85.70% 14.30% 3.33% 10.55% 0.36%
-101 90.45% 9.55% 2.48% 6.93% 0.08% -36 85.61% 14.39% 3.35% 10.63% 0.36%
-100 90.39% 9.61% 2.49% 6.98% 0.09% -35 85.53% 14.47% 3.36% 10.69% 0.37%
-99 90.33% 9.67% 2.51% 7.02% 0.09% -34 85.45% 14.55% 3.37% 10.75% 0.37%
-98 90.27% 9.73% 2.53% 7.06% 0.09% -33 85.36% 14.64% 3.39% 10.82% 0.38%
-97 90.21% 9.79% 2.53% 7.10% 0.09% -32 85.27% 14.73% 3.40% 10.89% 0.39%
-96 90.13% 9.87% 2.55% 7.16% 0.10% -31 85.17% 14.83% 3.41% 10.97% 0.40%
-95 90.07% 9.93% 2.56% 7.22% 0.10% -30 85.08% 14.92% 3.42% 11.04% 0.41%
-94 89.99% 10.01% 2.58% 7.27% 0.10% -29 84.99% 15.01% 3.43% 11.11% 0.41%
-93 89.92% 10.08% 2.59% 7.33% 0.11% -28 84.89% 15.11% 3.45% 11.19% 0.42%
-92 89.85% 10.15% 2.60% 7.38% 0.11% -27 84.82% 15.18% 3.46% 11.24% 0.42%
-91 89.78% 10.23% 2.62% 7.44% 0.11% -26 84.73% 15.27% 3.47% 11.31% 0.43%
-90 89.70% 10.30% 2.63% 7.50% 0.11% -25 84.63% 15.37% 3.48% 11.39% 0.44%
-89 89.65% 10.36% 2.63% 7.55% 0.11% -24 84.54% 15.46% 3.49% 11.45% 0.45%
-88 89.58% 10.42% 2.64% 7.60% 0.12% -23 84.46% 15.54% 3.50% 11.52% 0.46%
-87 89.52% 10.49% 2.65% 7.66% 0.12% -22 84.38% 15.62% 3.51% 11.58% 0.47%
-86 89.45% 10.55% 2.67% 7.71% 0.12% -21 84.28% 15.72% 3.53% 11.65% 0.48%
-85 89.36% 10.64% 2.68% 7.77% 0.13% -20 84.18% 15.82% 3.55% 11.72% 0.48%
-84 89.31% 10.70% 2.70% 7.81% 0.13% -19 84.10% 15.90% 3.56% 11.79% 0.49%
-83 89.23% 10.78% 2.71% 7.87% 0.14% -18 84.02% 15.98% 3.57% 11.85% 0.50%
-82 89.16% 10.84% 2.72% 7.92% 0.14% -17 83.91% 16.09% 3.59% 11.93% 0.51%
-81 89.09% 10.91% 2.73% 7.97% 0.15% -16 83.81% 16.19% 3.60% 12.01% 0.53%
-80 89.02% 10.99% 2.75% 8.03% 0.15% -15 83.73% 16.27% 3.61% 12.07% 0.53%
-79 88.95% 11.05% 2.77% 8.07% 0.15% -14 83.64% 16.36% 3.63% 12.14% 0.54%
-78 88.90% 11.11% 2.78% 8.11% 0.16% -13 83.54% 16.46% 3.64% 12.22% 0.54%
-77 88.83% 11.17% 2.79% 8.17% 0.16% -12 83.44% 16.56% 3.66% 12.29% 0.56%
-76 88.75% 11.25% 2.81% 8.22% 0.16% -11 83.36% 16.64% 3.67% 12.35% 0.56%
-75 88.69% 11.31% 2.82% 8.27% 0.17% -10 83.26% 16.75% 3.68% 12.43% 0.58%
-74 88.61% 11.39% 2.83% 8.34% 0.17% -9 83.16% 16.84% 3.69% 12.51% 0.58%
-73 88.53% 11.47% 2.84% 8.40% 0.17% -8 83.06% 16.94% 3.71% 12.58% 0.59%
-72 88.46% 11.54% 2.85% 8.46% 0.18% -7 82.97% 17.03% 3.72% 12.66% 0.60%
-71 88.39% 11.61% 2.86% 8.51% 0.18% -6 82.85% 17.15% 3.75% 12.74% 0.61%
-70 88.32% 11.68% 2.88% 8.56% 0.19% -5 82.75% 17.25% 3.76% 12.82% 0.62%
-69 88.25% 11.75% 2.90% 8.61% 0.19% -4 82.64% 17.36% 3.78% 12.90% 0.63%
-68 88.18% 11.82% 2.91% 8.66% 0.19% -3 82.55% 17.46% 3.80% 12.97% 0.63%
-67 88.10% 11.90% 2.93% 8.72% 0.20% -2 82.43% 17.57% 3.81% 13.06% 0.65%
-66 88.03% 11.97% 2.94% 8.78% 0.20% -1 82.33% 17.67% 3.82% 13.13% 0.66%
-65 87.96% 12.05% 2.95% 8.83% 0.21% 0 82.18% 17.82% 3.84% 13.20% 0.73%
-64 87.89% 12.11% 2.96% 8.88% 0.21% 1 82.08% 17.93% 3.85% 13.28% 0.73%
-63 87.81% 12.19% 2.98% 8.93% 0.22% 2 81.96% 18.04% 3.87% 13.37% 0.75%
-62 87.74% 12.26% 2.99% 8.99% 0.22% 3 81.85% 18.15% 3.89% 13.44% 0.76%
-61 87.66% 12.34% 3.00% 9.05% 0.23% 4 81.76% 18.24% 3.90% 13.52% 0.77%
-60 87.57% 12.43% 3.02% 9.13% 0.23% 5 81.65% 18.35% 3.92% 13.60% 0.78%
-59 87.49% 12.52% 3.03% 9.19% 0.24% 6 81.54% 18.46% 3.94% 13.68% 0.79%
-58 87.39% 12.61% 3.05% 9.26% 0.25% 7 81.44% 18.56% 3.95% 13.75% 0.80%
-57 87.33% 12.68% 3.05% 9.32% 0.25% 8 81.34% 18.66% 3.96% 13.83% 0.81%
-56 87.24% 12.76% 3.07% 9.38% 0.25% 9 81.25% 18.75% 3.97% 13.91% 0.82%
-55 87.17% 12.83% 3.07% 9.44% 0.26% 10 81.15% 18.85% 3.99% 13.98% 0.83%
-54 87.10% 12.90% 3.09% 9.49% 0.26% 11 81.04% 18.96% 4.00% 14.07% 0.84%
-53 87.04% 12.96% 3.10% 9.54% 0.27% 12 80.94% 19.06% 4.00% 14.15% 0.85%
-52 86.96% 13.04% 3.11% 9.60% 0.27% 13 80.85% 19.15% 4.02% 14.21% 0.86%
-51 86.87% 13.13% 3.13% 9.67% 0.28% 14 80.77% 19.24% 4.03% 14.28% 0.87%
-50 86.79% 13.21% 3.15% 9.73% 0.28% 15 80.65% 19.35% 4.04% 14.37% 0.88%
-49 86.72% 13.29% 3.16% 9.78% 0.29% 16 80.53% 19.47% 4.06% 14.46% 0.89%
-48 86.62% 13.38% 3.17% 9.85% 0.29% 17 80.44% 19.56% 4.08% 14.53% 0.91%
-47 86.53% 13.47% 3.20% 9.92% 0.30% 18 80.34% 19.66% 4.09% 14.60% 0.92%
221
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 19 80.22% 19.78% 4.10% 14.69% 0.94% 84 72.26% 27.74% 5.10% 20.47% 2.12%
20 80.10% 19.90% 4.12% 14.79% 0.95% 85 72.13% 27.87% 5.11% 20.56% 2.14%
21 79.96% 20.04% 4.13% 14.89% 0.96% 86 71.99% 28.01% 5.13% 20.65% 2.17%
22 79.85% 20.15% 4.15% 14.97% 0.98% 87 71.87% 28.13% 5.15% 20.73% 2.18%
23 79.72% 20.28% 4.17% 15.06% 0.99% 88 71.74% 28.26% 5.17% 20.83% 2.21%
24 79.61% 20.39% 4.18% 15.14% 1.01% 89 71.61% 28.39% 5.19% 20.91% 2.24%
25 79.49% 20.51% 4.19% 15.23% 1.03% 90 71.48% 28.52% 5.21% 20.99% 2.26%
26 79.38% 20.62% 4.21% 15.31% 1.04% 91 71.35% 28.65% 5.22% 21.09% 2.29%
27 79.26% 20.74% 4.23% 15.40% 1.05% 92 71.23% 28.77% 5.23% 21.18% 2.31%
28 79.14% 20.86% 4.26% 15.48% 1.07% 93 71.10% 28.90% 5.24% 21.27% 2.33%
29 79.02% 20.98% 4.27% 15.57% 1.08% 94 71.00% 29.00% 5.25% 21.34% 2.35%
30 78.92% 21.09% 4.28% 15.65% 1.10% 95 70.87% 29.13% 5.27% 21.43% 2.38%
31 78.82% 21.18% 4.29% 15.72% 1.11% 96 70.73% 29.27% 5.30% 21.52% 2.39%
32 78.69% 21.31% 4.31% 15.81% 1.13% 97 70.57% 29.43% 5.32% 21.63% 2.43%
33 78.58% 21.43% 4.33% 15.90% 1.14% 98 70.45% 29.55% 5.32% 21.73% 2.45%
34 78.46% 21.54% 4.34% 15.98% 1.16% 99 70.34% 29.66% 5.33% 21.81% 2.47%
35 78.34% 21.66% 4.35% 16.08% 1.18% 100 70.21% 29.79% 5.35% 21.90% 2.48%
36 78.23% 21.77% 4.37% 16.15% 1.20% 101 70.08% 29.92% 5.36% 22.00% 2.51%
37 78.12% 21.88% 4.39% 16.23% 1.21% 102 69.96% 30.04% 5.37% 22.08% 2.53%
38 77.99% 22.01% 4.41% 16.32% 1.22% 103 69.85% 30.15% 5.38% 22.17% 2.55%
39 77.88% 22.12% 4.43% 16.40% 1.23% 104 69.73% 30.27% 5.40% 22.26% 2.56%
40 77.77% 22.23% 4.44% 16.48% 1.25% 105 69.60% 30.40% 5.41% 22.35% 2.58%
41 77.65% 22.35% 4.46% 16.56% 1.26% 106 69.47% 30.53% 5.43% 22.44% 2.60%
42 77.53% 22.47% 4.48% 16.65% 1.29% 107 69.36% 30.64% 5.44% 22.52% 2.63%
43 77.42% 22.58% 4.48% 16.74% 1.30% 108 69.23% 30.77% 5.44% 22.61% 2.66%
44 77.29% 22.71% 4.50% 16.83% 1.33% 109 69.10% 30.90% 5.46% 22.70% 2.68%
45 77.17% 22.83% 4.51% 16.92% 1.34% 110 68.98% 31.02% 5.47% 22.78% 2.71%
46 77.05% 22.95% 4.53% 17.01% 1.36% 111 68.86% 31.14% 5.50% 22.86% 2.73%
47 76.91% 23.09% 4.55% 17.11% 1.38% 112 68.72% 31.28% 5.51% 22.96% 2.75%
48 76.80% 23.20% 4.56% 17.19% 1.40% 113 68.58% 31.42% 5.52% 23.06% 2.79%
49 76.68% 23.32% 4.58% 17.27% 1.42% 114 68.45% 31.55% 5.53% 23.15% 2.81%
50 76.54% 23.46% 4.60% 17.37% 1.44% 115 68.31% 31.69% 5.55% 23.23% 2.85%
51 76.44% 23.56% 4.61% 17.44% 1.46% 116 68.17% 31.83% 5.56% 23.33% 2.88%
52 76.32% 23.68% 4.63% 17.52% 1.48% 117 68.04% 31.96% 5.58% 23.41% 2.92%
53 76.21% 23.79% 4.64% 17.60% 1.49% 118 67.91% 32.09% 5.59% 23.50% 2.95%
54 76.07% 23.93% 4.65% 17.70% 1.52% 119 67.79% 32.21% 5.60% 23.57% 2.98%
55 75.94% 24.06% 4.67% 17.78% 1.55% 120 67.66% 32.34% 5.62% 23.66% 3.01%
56 75.82% 24.18% 4.68% 17.88% 1.57% 121 67.54% 32.46% 5.62% 23.75% 3.03%
57 75.70% 24.30% 4.69% 17.97% 1.58% 122 67.40% 32.60% 5.64% 23.85% 3.05%
58 75.57% 24.43% 4.71% 18.07% 1.60% 123 67.28% 32.72% 5.66% 23.93% 3.08%
59 75.45% 24.55% 4.72% 18.15% 1.61% 124 67.15% 32.85% 5.67% 24.02% 3.10%
60 75.32% 24.68% 4.74% 18.25% 1.63% 125 67.02% 32.99% 5.69% 24.11% 3.13%
61 75.21% 24.79% 4.76% 18.32% 1.66% 126 66.89% 33.11% 5.70% 24.20% 3.15%
62 75.08% 24.92% 4.77% 18.42% 1.67% 127 66.75% 33.25% 5.72% 24.30% 3.18%
63 74.98% 25.03% 4.79% 18.49% 1.70% 128 66.62% 33.38% 5.73% 24.38% 3.22%
64 74.85% 25.16% 4.81% 18.58% 1.71% 129 66.48% 33.52% 5.75% 24.46% 3.25%
65 74.71% 25.29% 4.83% 18.68% 1.73% 130 66.36% 33.64% 5.76% 24.55% 3.28%
66 74.57% 25.43% 4.85% 18.78% 1.75% 131 66.22% 33.78% 5.77% 24.63% 3.32%
67 74.44% 25.56% 4.86% 18.88% 1.76% 132 66.10% 33.90% 5.78% 24.72% 3.35%
68 74.33% 25.67% 4.87% 18.96% 1.79% 133 65.97% 34.03% 5.79% 24.80% 3.38%
69 74.19% 25.81% 4.88% 19.06% 1.81% 134 65.83% 34.17% 5.80% 24.89% 3.42%
70 74.07% 25.93% 4.89% 19.15% 1.83% 135 65.70% 34.30% 5.82% 24.99% 3.44%
71 73.96% 26.05% 4.90% 19.24% 1.85% 136 65.59% 34.41% 5.82% 25.07% 3.46%
72 73.82% 26.18% 4.91% 19.34% 1.87% 137 65.47% 34.53% 5.83% 25.16% 3.49%
73 73.70% 26.30% 4.93% 19.42% 1.89% 138 65.34% 34.66% 5.85% 25.24% 3.52%
74 73.57% 26.44% 4.95% 19.51% 1.91% 139 65.22% 34.78% 5.86% 25.31% 3.55%
75 73.43% 26.57% 4.97% 19.61% 1.94% 140 65.09% 34.91% 5.87% 25.40% 3.57%
76 73.29% 26.71% 4.98% 19.71% 1.96% 141 64.96% 35.05% 5.89% 25.49% 3.61%
77 73.16% 26.84% 5.00% 19.80% 1.99% 142 64.84% 35.16% 5.89% 25.58% 3.63%
78 73.04% 26.96% 5.01% 19.89% 2.01% 143 64.71% 35.29% 5.91% 25.66% 3.66%
79 72.89% 27.11% 5.02% 20.00% 2.02% 144 64.59% 35.41% 5.93% 25.74% 3.69%
80 72.75% 27.25% 5.04% 20.10% 2.05% 145 64.47% 35.53% 5.94% 25.81% 3.72%
81 72.64% 27.36% 5.07% 20.17% 2.07% 146 64.36% 35.64% 5.96% 25.89% 3.74%
82 72.52% 27.49% 5.08% 20.26% 2.09% 147 64.24% 35.77% 5.96% 25.98% 3.77%
83 72.38% 27.62% 5.09% 20.37% 2.10% 148 64.11% 35.90% 5.98% 26.07% 3.80%
222
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 149 63.97% 36.03% 5.99% 26.15% 3.83% 214 56.25% 43.75% 6.76% 31.30% 5.63%
150 63.83% 36.17% 6.00% 26.25% 3.86% 215 56.14% 43.86% 6.77% 31.38% 5.66%
151 63.71% 36.29% 6.01% 26.33% 3.89% 216 56.03% 43.97% 6.78% 31.45% 5.69%
152 63.59% 36.41% 6.02% 26.41% 3.92% 217 55.92% 44.08% 6.79% 31.52% 5.72%
153 63.45% 36.55% 6.04% 26.50% 3.95% 218 55.81% 44.19% 6.80% 31.59% 5.75%
154 63.34% 36.66% 6.05% 26.58% 3.97% 219 55.70% 44.30% 6.81% 31.66% 5.78%
155 63.22% 36.78% 6.06% 26.66% 4.00% 220 55.59% 44.42% 6.81% 31.74% 5.80%
156 63.08% 36.92% 6.08% 26.77% 4.02% 221 55.47% 44.53% 6.82% 31.82% 5.83%
157 62.98% 37.03% 6.09% 26.83% 4.05% 222 55.36% 44.64% 6.83% 31.89% 5.86%
158 62.85% 37.15% 6.10% 26.92% 4.08% 223 55.25% 44.75% 6.84% 31.97% 5.88%
159 62.73% 37.27% 6.11% 26.99% 4.11% 224 55.16% 44.84% 6.85% 32.03% 5.91%
160 62.61% 37.39% 6.12% 27.06% 4.14% 225 55.06% 44.94% 6.85% 32.09% 5.94%
161 62.48% 37.52% 6.14% 27.15% 4.17% 226 54.96% 45.04% 6.86% 32.16% 5.96%
162 62.35% 37.65% 6.15% 27.25% 4.19% 227 54.85% 45.15% 6.87% 32.22% 6.00%
163 62.22% 37.78% 6.16% 27.34% 4.22% 228 54.75% 45.26% 6.88% 32.29% 6.03%
164 62.09% 37.91% 6.17% 27.43% 4.25% 229 54.65% 45.35% 6.88% 32.35% 6.06%
165 61.97% 38.03% 6.19% 27.50% 4.28% 230 54.53% 45.47% 6.90% 32.43% 6.09%
166 61.85% 38.16% 6.20% 27.58% 4.32% 231 54.41% 45.59% 6.91% 32.51% 6.12%
167 61.74% 38.26% 6.21% 27.65% 4.34% 232 54.28% 45.73% 6.93% 32.59% 6.15%
168 61.62% 38.38% 6.23% 27.72% 4.37% 233 54.17% 45.83% 6.93% 32.66% 6.18%
169 61.51% 38.49% 6.24% 27.80% 4.40% 234 54.05% 45.95% 6.94% 32.74% 6.21%
170 61.38% 38.62% 6.25% 27.88% 4.43% 235 53.94% 46.07% 6.96% 32.81% 6.24%
171 61.28% 38.72% 6.26% 27.95% 4.46% 236 53.83% 46.17% 6.96% 32.88% 6.27%
172 61.15% 38.85% 6.27% 28.04% 4.49% 237 53.71% 46.29% 6.97% 32.95% 6.31%
173 61.01% 38.99% 6.28% 28.14% 4.51% 238 53.61% 46.39% 6.98% 33.02% 6.33%
174 60.88% 39.12% 6.29% 28.22% 4.55% 239 53.47% 46.53% 6.99% 33.12% 6.36%
175 60.75% 39.25% 6.30% 28.31% 4.58% 240 53.38% 46.62% 7.00% 33.19% 6.38%
176 60.63% 39.37% 6.31% 28.39% 4.61% 241 53.28% 46.72% 7.01% 33.26% 6.39%
177 60.50% 39.50% 6.32% 28.48% 4.64% 242 53.18% 46.83% 7.01% 33.33% 6.42%
178 60.38% 39.62% 6.33% 28.56% 4.67% 243 53.07% 46.93% 7.02% 33.40% 6.45%
179 60.26% 39.74% 6.34% 28.65% 4.70% 244 52.96% 47.04% 7.04% 33.46% 6.48%
180 60.13% 39.87% 6.35% 28.74% 4.73% 245 52.86% 47.15% 7.05% 33.53% 6.51%
181 60.00% 40.00% 6.37% 28.81% 4.76% 246 52.76% 47.24% 7.06% 33.59% 6.53%
182 59.89% 40.11% 6.38% 28.88% 4.80% 247 52.65% 47.35% 7.07% 33.66% 6.56%
183 59.78% 40.22% 6.39% 28.95% 4.82% 248 52.54% 47.46% 7.08% 33.73% 6.59%
184 59.68% 40.32% 6.41% 29.02% 4.84% 249 52.46% 47.55% 7.10% 33.78% 6.61%
185 59.58% 40.43% 6.42% 29.08% 4.87% 250 52.35% 47.65% 7.10% 33.85% 6.64%
186 59.47% 40.53% 6.43% 29.15% 4.89% 251 52.25% 47.75% 7.11% 33.91% 6.67%
187 59.35% 40.65% 6.45% 29.23% 4.91% 252 52.15% 47.85% 7.12% 33.98% 6.70%
188 59.24% 40.76% 6.46% 29.31% 4.93% 253 52.04% 47.96% 7.13% 34.05% 6.72%
189 59.12% 40.88% 6.47% 29.40% 4.95% 254 51.93% 48.07% 7.13% 34.13% 6.75%
190 59.00% 41.00% 6.49% 29.47% 4.99% 255 51.83% 48.17% 7.14% 34.19% 6.78%
191 58.87% 41.14% 6.50% 29.56% 5.02% 256 51.74% 48.26% 7.15% 34.25% 6.80%
192 58.76% 41.24% 6.51% 29.63% 5.04% 257 51.65% 48.35% 7.15% 34.31% 6.83%
193 58.63% 41.37% 6.52% 29.72% 5.07% 258 51.55% 48.45% 7.16% 34.37% 6.86%
194 58.52% 41.48% 6.54% 29.80% 5.09% 259 51.45% 48.55% 7.17% 34.44% 6.88%
195 58.42% 41.58% 6.55% 29.86% 5.11% 260 51.35% 48.65% 7.18% 34.51% 6.91%
196 58.30% 41.71% 6.57% 29.95% 5.13% 261 51.25% 48.75% 7.18% 34.58% 6.93%
197 58.17% 41.83% 6.58% 30.03% 5.16% 262 51.13% 48.87% 7.19% 34.65% 6.97%
198 58.03% 41.97% 6.59% 30.13% 5.18% 263 51.03% 48.97% 7.20% 34.71% 7.00%
199 57.92% 42.08% 6.60% 30.21% 5.21% 264 50.94% 49.06% 7.21% 34.77% 7.02%
200 57.80% 42.20% 6.61% 30.29% 5.24% 265 50.83% 49.17% 7.21% 34.84% 7.06%
201 57.68% 42.32% 6.62% 30.36% 5.28% 266 50.73% 49.27% 7.22% 34.91% 7.08%
202 57.57% 42.43% 6.63% 30.43% 5.30% 267 50.63% 49.37% 7.23% 34.97% 7.11%
203 57.46% 42.54% 6.65% 30.51% 5.34% 268 50.54% 49.47% 7.24% 35.03% 7.13%
204 57.35% 42.65% 6.66% 30.58% 5.35% 269 50.43% 49.57% 7.25% 35.11% 7.16%
205 57.25% 42.75% 6.66% 30.65% 5.38% 270 50.33% 49.67% 7.26% 35.17% 7.19%
206 57.12% 42.88% 6.67% 30.74% 5.41% 271 50.23% 49.77% 7.28% 35.23% 7.21%
207 57.01% 42.99% 6.68% 30.81% 5.43% 272 50.14% 49.86% 7.29% 35.29% 7.23%
208 56.91% 43.09% 6.69% 30.88% 5.46% 273 50.03% 49.97% 7.29% 35.36% 7.26%
209 56.81% 43.19% 6.70% 30.95% 5.48% 274 49.92% 50.08% 7.31% 35.42% 7.30%
210 56.69% 43.31% 6.72% 31.03% 5.51% 275 49.84% 50.17% 7.31% 35.47% 7.32%
211 56.57% 43.43% 6.73% 31.09% 5.54% 276 49.72% 50.28% 7.32% 35.56% 7.34%
212 56.46% 43.55% 6.74% 31.17% 5.58% 277 49.62% 50.38% 7.32% 35.62% 7.38%
213 56.35% 43.65% 6.75% 31.24% 5.61% 278 49.51% 50.49% 7.33% 35.69% 7.41%
223
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 279 49.41% 50.59% 7.35% 35.74% 7.44% 344 43.74% 56.26% 7.79% 39.38% 9.04%
280 49.31% 50.69% 7.36% 35.80% 7.47% 345 43.66% 56.34% 7.80% 39.42% 9.06%
281 49.23% 50.77% 7.37% 35.85% 7.49% 346 43.55% 56.45% 7.80% 39.49% 9.10%
282 49.13% 50.87% 7.38% 35.92% 7.52% 347 43.48% 56.52% 7.81% 39.54% 9.12%
283 49.04% 50.96% 7.38% 35.98% 7.55% 348 43.39% 56.62% 7.82% 39.59% 9.15%
284 48.94% 51.06% 7.39% 36.03% 7.58% 349 43.30% 56.70% 7.82% 39.65% 9.17%
285 48.85% 51.15% 7.40% 36.08% 7.61% 350 43.20% 56.80% 7.83% 39.71% 9.21%
286 48.74% 51.26% 7.42% 36.16% 7.63% 351 43.11% 56.89% 7.83% 39.76% 9.24%
287 48.65% 51.35% 7.43% 36.20% 7.66% 352 43.05% 56.95% 7.84% 39.80% 9.26%
288 48.56% 51.44% 7.44% 36.26% 7.69% 353 42.96% 57.04% 7.84% 39.86% 9.28%
289 48.47% 51.53% 7.45% 36.33% 7.71% 354 42.88% 57.12% 7.84% 39.91% 9.31%
290 48.38% 51.63% 7.45% 36.38% 7.74% 355 42.81% 57.19% 7.85% 39.95% 9.33%
291 48.29% 51.71% 7.46% 36.43% 7.76% 356 42.74% 57.26% 7.86% 39.99% 9.36%
292 48.21% 51.79% 7.47% 36.48% 7.79% 357 42.68% 57.32% 7.86% 40.02% 9.38%
293 48.12% 51.88% 7.47% 36.53% 7.82% 358 42.61% 57.39% 7.87% 40.07% 9.39%
294 48.03% 51.97% 7.48% 36.59% 7.84% 359 42.54% 57.46% 7.88% 40.12% 9.41%
295 47.94% 52.06% 7.49% 36.64% 7.87% 360 42.45% 57.55% 7.88% 40.18% 9.44%
296 47.86% 52.14% 7.49% 36.69% 7.89% 361 42.36% 57.64% 7.89% 40.23% 9.47%
297 47.77% 52.23% 7.51% 36.75% 7.92% 362 42.28% 57.72% 7.89% 40.27% 9.50%
298 47.67% 52.33% 7.51% 36.81% 7.95% 363 42.21% 57.79% 7.90% 40.32% 9.52%
299 47.59% 52.41% 7.52% 36.87% 7.97% 364 42.12% 57.88% 7.90% 40.38% 9.55%
300 47.50% 52.50% 7.52% 36.93% 7.99% 365 42.06% 57.94% 7.91% 40.41% 9.57%
301 47.43% 52.57% 7.53% 36.97% 8.01% 366 41.99% 58.01% 7.91% 40.45% 9.59%
302 47.34% 52.66% 7.54% 37.03% 8.04% 367 41.93% 58.07% 7.92% 40.49% 9.61%
303 47.26% 52.74% 7.54% 37.08% 8.06% 368 41.85% 58.15% 7.92% 40.54% 9.64%
304 47.18% 52.82% 7.55% 37.13% 8.08% 369 41.78% 58.22% 7.93% 40.58% 9.66%
305 47.10% 52.90% 7.55% 37.18% 8.11% 370 41.69% 58.31% 7.94% 40.64% 9.68%
306 47.00% 53.00% 7.55% 37.26% 8.13% 371 41.62% 58.38% 7.94% 40.68% 9.71%
307 46.93% 53.07% 7.55% 37.31% 8.15% 372 41.54% 58.46% 7.95% 40.72% 9.73%
308 46.84% 53.16% 7.56% 37.36% 8.18% 373 41.46% 58.54% 7.95% 40.78% 9.75%
309 46.76% 53.24% 7.57% 37.41% 8.20% 374 41.37% 58.63% 7.96% 40.83% 9.78%
310 46.66% 53.34% 7.58% 37.47% 8.23% 375 41.30% 58.70% 7.97% 40.88% 9.80%
311 46.57% 53.43% 7.58% 37.54% 8.26% 376 41.21% 58.79% 7.97% 40.94% 9.83%
312 46.46% 53.54% 7.59% 37.60% 8.29% 377 41.14% 58.86% 7.98% 40.98% 9.85%
313 46.36% 53.64% 7.60% 37.67% 8.31% 378 41.06% 58.94% 7.98% 41.03% 9.87%
314 46.28% 53.72% 7.60% 37.72% 8.34% 379 41.00% 59.00% 7.98% 41.08% 9.88%
315 46.18% 53.82% 7.61% 37.78% 8.37% 380 40.93% 59.07% 7.99% 41.12% 9.91%
316 46.10% 53.91% 7.63% 37.84% 8.38% 381 40.86% 59.14% 7.99% 41.16% 9.93%
317 46.00% 54.00% 7.64% 37.90% 8.40% 382 40.76% 59.24% 8.00% 41.22% 9.96%
318 45.92% 54.08% 7.64% 37.95% 8.43% 383 40.69% 59.32% 8.01% 41.27% 9.98%
319 45.84% 54.17% 7.65% 38.01% 8.45% 384 40.61% 59.39% 8.02% 41.31% 10.01%
320 45.74% 54.26% 7.65% 38.08% 8.48% 385 40.53% 59.47% 8.02% 41.36% 10.03%
321 45.66% 54.34% 7.66% 38.12% 8.50% 386 40.46% 59.54% 8.03% 41.40% 10.05%
322 45.58% 54.42% 7.66% 38.18% 8.52% 387 40.39% 59.61% 8.03% 41.45% 10.07%
323 45.51% 54.49% 7.67% 38.22% 8.54% 388 40.32% 59.68% 8.03% 41.49% 10.10%
324 45.43% 54.57% 7.68% 38.28% 8.56% 389 40.24% 59.76% 8.04% 41.55% 10.12%
325 45.35% 54.66% 7.68% 38.34% 8.58% 390 40.18% 59.82% 8.04% 41.59% 10.14%
326 45.27% 54.73% 7.68% 38.39% 8.61% 391 40.10% 59.90% 8.04% 41.64% 10.17%
327 45.20% 54.81% 7.69% 38.43% 8.63% 392 40.02% 59.98% 8.05% 41.69% 10.19%
328 45.11% 54.89% 7.69% 38.48% 8.66% 393 39.95% 60.05% 8.05% 41.73% 10.21%
329 45.02% 54.98% 7.70% 38.53% 8.69% 394 39.88% 60.12% 8.06% 41.78% 10.23%
330 44.93% 55.07% 7.71% 38.59% 8.72% 395 39.80% 60.20% 8.06% 41.83% 10.25%
331 44.84% 55.16% 7.71% 38.65% 8.74% 396 39.74% 60.26% 8.07% 41.87% 10.26%
332 44.76% 55.25% 7.72% 38.71% 8.76% 397 39.67% 60.33% 8.07% 41.91% 10.28%
333 44.67% 55.33% 7.72% 38.76% 8.79% 398 39.61% 60.39% 8.07% 41.94% 10.31%
334 44.59% 55.41% 7.73% 38.81% 8.81% 399 39.54% 60.46% 8.08% 41.99% 10.34%
335 44.50% 55.50% 7.73% 38.87% 8.84% 400 39.46% 60.54% 8.08% 42.04% 10.36%
336 44.42% 55.58% 7.74% 38.92% 8.86% 401 39.38% 60.62% 8.09% 42.09% 10.38%
337 44.34% 55.67% 7.75% 38.98% 8.88% 402 39.33% 60.67% 8.09% 42.13% 10.40%
338 44.24% 55.76% 7.75% 39.04% 8.91% 403 39.27% 60.73% 8.09% 42.16% 10.42%
339 44.15% 55.85% 7.76% 39.11% 8.93% 404 39.22% 60.78% 8.10% 42.20% 10.43%
340 44.08% 55.92% 7.77% 39.16% 8.95% 405 39.16% 60.85% 8.10% 42.24% 10.45%
341 43.99% 56.02% 7.77% 39.22% 8.96% 406 39.08% 60.93% 8.10% 42.29% 10.47%
342 43.91% 56.09% 7.78% 39.27% 8.98% 407 39.01% 60.99% 8.11% 42.33% 10.49%
343 43.82% 56.18% 7.78% 39.33% 9.01% 408 38.94% 61.06% 8.11% 42.38% 10.51%
224
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 409 38.87% 61.13% 8.12% 42.42% 10.53% 474 34.71% 65.29% 8.40% 44.99% 11.85%
410 38.81% 61.19% 8.13% 42.45% 10.55% 475 34.65% 65.35% 8.40% 45.03% 11.87%
411 38.75% 61.26% 8.13% 42.50% 10.57% 476 34.58% 65.42% 8.40% 45.06% 11.89%
412 38.67% 61.33% 8.14% 42.55% 10.59% 477 34.52% 65.48% 8.40% 45.10% 11.92%
413 38.61% 61.39% 8.14% 42.59% 10.60% 478 34.46% 65.54% 8.41% 45.14% 11.93%
414 38.55% 61.45% 8.15% 42.62% 10.63% 479 34.41% 65.59% 8.41% 45.17% 11.95%
415 38.50% 61.50% 8.15% 42.65% 10.64% 480 34.37% 65.63% 8.41% 45.20% 11.96%
416 38.43% 61.57% 8.16% 42.69% 10.66% 481 34.31% 65.69% 8.42% 45.24% 11.98%
417 38.36% 61.64% 8.16% 42.73% 10.68% 482 34.25% 65.75% 8.42% 45.27% 12.00%
418 38.28% 61.72% 8.17% 42.79% 10.71% 483 34.17% 65.83% 8.43% 45.32% 12.03%
419 38.20% 61.80% 8.17% 42.83% 10.73% 484 34.12% 65.88% 8.43% 45.35% 12.04%
420 38.12% 61.88% 8.18% 42.89% 10.76% 485 34.06% 65.94% 8.43% 45.39% 12.07%
421 38.06% 61.95% 8.18% 42.92% 10.79% 486 34.00% 66.00% 8.44% 45.42% 12.08%
422 37.99% 62.01% 8.19% 42.96% 10.81% 487 33.94% 66.06% 8.44% 45.47% 12.10%
423 37.95% 62.05% 8.19% 42.99% 10.82% 488 33.87% 66.13% 8.45% 45.51% 12.11%
424 37.88% 62.12% 8.19% 43.03% 10.84% 489 33.82% 66.18% 8.45% 45.55% 12.13%
425 37.81% 62.19% 8.20% 43.08% 10.85% 490 33.76% 66.24% 8.46% 45.57% 12.15%
426 37.76% 62.24% 8.20% 43.12% 10.87% 491 33.71% 66.29% 8.46% 45.60% 12.17%
427 37.69% 62.31% 8.20% 43.16% 10.89% 492 33.67% 66.33% 8.46% 45.63% 12.18%
428 37.62% 62.38% 8.21% 43.21% 10.91% 493 33.61% 66.40% 8.47% 45.67% 12.20%
429 37.55% 62.45% 8.21% 43.25% 10.93% 494 33.55% 66.45% 8.47% 45.70% 12.22%
430 37.46% 62.54% 8.22% 43.31% 10.96% 495 33.49% 66.51% 8.48% 45.73% 12.24%
431 37.40% 62.60% 8.22% 43.35% 10.97% 496 33.44% 66.56% 8.48% 45.76% 12.27%
432 37.34% 62.66% 8.23% 43.39% 10.99% 497 33.36% 66.64% 8.48% 45.81% 12.30%
433 37.27% 62.73% 8.23% 43.43% 11.01% 498 33.30% 66.70% 8.49% 45.85% 12.31%
434 37.20% 62.80% 8.24% 43.48% 11.03% 499 33.23% 66.77% 8.49% 45.89% 12.34%
435 37.15% 62.85% 8.24% 43.50% 11.05% 500 33.17% 66.84% 8.49% 45.92% 12.36%
436 37.09% 62.91% 8.24% 43.55% 11.06% 501 33.11% 66.89% 8.50% 45.95% 12.38%
437 37.03% 62.97% 8.24% 43.59% 11.08% 502 33.06% 66.94% 8.50% 45.98% 12.40%
438 36.97% 63.04% 8.25% 43.62% 11.10% 503 33.00% 67.00% 8.50% 46.02% 12.42%
439 36.91% 63.09% 8.25% 43.66% 11.12% 504 32.95% 67.05% 8.51% 46.06% 12.43%
440 36.84% 63.16% 8.26% 43.69% 11.15% 505 32.89% 67.11% 8.51% 46.09% 12.46%
441 36.78% 63.22% 8.26% 43.73% 11.16% 506 32.83% 67.17% 8.51% 46.12% 12.48%
442 36.72% 63.29% 8.27% 43.77% 11.19% 507 32.77% 67.23% 8.52% 46.16% 12.50%
443 36.64% 63.36% 8.27% 43.82% 11.21% 508 32.72% 67.28% 8.52% 46.19% 12.52%
444 36.58% 63.42% 8.28% 43.85% 11.23% 509 32.66% 67.34% 8.52% 46.23% 12.53%
445 36.52% 63.48% 8.28% 43.89% 11.25% 510 32.61% 67.39% 8.53% 46.26% 12.55%
446 36.46% 63.55% 8.29% 43.92% 11.28% 511 32.54% 67.46% 8.53% 46.30% 12.57%
447 36.39% 63.61% 8.29% 43.96% 11.30% 512 32.47% 67.53% 8.54% 46.34% 12.59%
448 36.33% 63.67% 8.30% 44.00% 11.32% 513 32.41% 67.59% 8.54% 46.38% 12.61%
449 36.27% 63.73% 8.30% 44.03% 11.34% 514 32.38% 67.63% 8.54% 46.40% 12.62%
450 36.21% 63.79% 8.30% 44.07% 11.36% 515 32.31% 67.69% 8.55% 46.44% 12.65%
451 36.15% 63.85% 8.31% 44.11% 11.38% 516 32.26% 67.75% 8.55% 46.47% 12.67%
452 36.08% 63.92% 8.31% 44.15% 11.41% 517 32.20% 67.80% 8.55% 46.50% 12.69%
453 36.02% 63.99% 8.31% 44.19% 11.42% 518 32.14% 67.86% 8.55% 46.54% 12.71%
454 35.94% 64.06% 8.32% 44.24% 11.44% 519 32.08% 67.92% 8.55% 46.56% 12.75%
455 35.87% 64.13% 8.32% 44.29% 11.46% 520 32.02% 67.98% 8.56% 46.60% 12.76%
456 35.81% 64.19% 8.32% 44.32% 11.49% 521 31.97% 68.03% 8.56% 46.63% 12.78%
457 35.74% 64.26% 8.33% 44.36% 11.51% 522 31.92% 68.08% 8.56% 46.67% 12.80%
458 35.70% 64.30% 8.33% 44.39% 11.53% 523 31.87% 68.13% 8.56% 46.69% 12.82%
459 35.64% 64.36% 8.34% 44.42% 11.55% 524 31.81% 68.19% 8.56% 46.72% 12.84%
460 35.58% 64.42% 8.34% 44.45% 11.57% 525 31.77% 68.23% 8.57% 46.75% 12.86%
461 35.51% 64.49% 8.34% 44.49% 11.60% 526 31.72% 68.28% 8.57% 46.79% 12.87%
462 35.44% 64.56% 8.35% 44.53% 11.62% 527 31.66% 68.34% 8.57% 46.81% 12.90%
463 35.39% 64.61% 8.35% 44.57% 11.64% 528 31.61% 68.39% 8.57% 46.85% 12.91%
464 35.32% 64.68% 8.35% 44.61% 11.65% 529 31.57% 68.43% 8.58% 46.87% 12.93%
465 35.27% 64.73% 8.36% 44.65% 11.67% 530 31.53% 68.47% 8.58% 46.89% 12.94%
466 35.21% 64.79% 8.36% 44.69% 11.68% 531 31.48% 68.52% 8.58% 46.93% 12.95%
467 35.15% 64.85% 8.36% 44.72% 11.71% 532 31.43% 68.57% 8.58% 46.96% 12.97%
468 35.10% 64.90% 8.37% 44.75% 11.72% 533 31.36% 68.65% 8.59% 47.00% 13.00%
469 35.05% 64.95% 8.37% 44.78% 11.74% 534 31.31% 68.70% 8.59% 47.03% 13.02%
470 34.98% 65.02% 8.38% 44.83% 11.75% 535 31.24% 68.76% 8.59% 47.07% 13.04%
471 34.92% 65.08% 8.38% 44.87% 11.78% 536 31.19% 68.81% 8.60% 47.09% 13.06%
472 34.85% 65.15% 8.39% 44.90% 11.80% 537 31.14% 68.86% 8.60% 47.13% 13.07%
473 34.78% 65.22% 8.39% 44.94% 11.83% 538 31.09% 68.91% 8.60% 47.16% 13.09%
225
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 539 31.04% 68.96% 8.61% 47.19% 13.11% 604 27.93% 72.07% 8.77% 49.05% 14.19%
540 31.00% 69.00% 8.61% 47.22% 13.12% 605 27.88% 72.12% 8.77% 49.08% 14.21%
541 30.94% 69.06% 8.61% 47.25% 13.14% 606 27.84% 72.16% 8.77% 49.10% 14.22%
542 30.89% 69.12% 8.62% 47.28% 13.16% 607 27.80% 72.20% 8.78% 49.13% 14.24%
543 30.83% 69.17% 8.62% 47.31% 13.18% 608 27.75% 72.25% 8.78% 49.15% 14.26%
544 30.79% 69.22% 8.62% 47.34% 13.20% 609 27.72% 72.29% 8.78% 49.18% 14.28%
545 30.73% 69.27% 8.62% 47.38% 13.21% 610 27.67% 72.33% 8.78% 49.20% 14.30%
546 30.68% 69.32% 8.63% 47.41% 13.23% 611 27.62% 72.38% 8.78% 49.22% 14.32%
547 30.63% 69.38% 8.63% 47.44% 13.25% 612 27.58% 72.43% 8.78% 49.26% 14.33%
548 30.58% 69.42% 8.63% 47.46% 13.27% 613 27.53% 72.47% 8.78% 49.28% 14.35%
549 30.54% 69.46% 8.63% 47.48% 13.28% 614 27.48% 72.52% 8.79% 49.31% 14.37%
550 30.49% 69.51% 8.64% 47.51% 13.31% 615 27.43% 72.57% 8.79% 49.33% 14.39%
551 30.44% 69.56% 8.64% 47.55% 13.32% 616 27.39% 72.62% 8.79% 49.36% 14.40%
552 30.39% 69.61% 8.64% 47.57% 13.34% 617 27.34% 72.66% 8.79% 49.39% 14.42%
553 30.33% 69.67% 8.64% 47.61% 13.36% 618 27.30% 72.70% 8.80% 49.42% 14.43%
554 30.28% 69.72% 8.65% 47.65% 13.37% 619 27.24% 72.76% 8.80% 49.45% 14.45%
555 30.23% 69.77% 8.65% 47.68% 13.39% 620 27.19% 72.81% 8.80% 49.48% 14.47%
556 30.17% 69.83% 8.65% 47.71% 13.41% 621 27.14% 72.86% 8.81% 49.51% 14.49%
557 30.14% 69.86% 8.65% 47.73% 13.43% 622 27.10% 72.91% 8.81% 49.53% 14.51%
558 30.09% 69.91% 8.66% 47.75% 13.45% 623 27.06% 72.94% 8.81% 49.55% 14.52%
559 30.04% 69.97% 8.66% 47.78% 13.47% 624 27.03% 72.98% 8.81% 49.57% 14.53%
560 30.00% 70.00% 8.66% 47.81% 13.48% 625 26.99% 73.01% 8.82% 49.59% 14.55%
561 29.94% 70.06% 8.67% 47.85% 13.49% 626 26.94% 73.06% 8.82% 49.62% 14.56%
562 29.89% 70.11% 8.67% 47.87% 13.52% 627 26.89% 73.11% 8.82% 49.65% 14.58%
563 29.85% 70.15% 8.67% 47.90% 13.53% 628 26.85% 73.15% 8.82% 49.68% 14.59%
564 29.81% 70.19% 8.67% 47.92% 13.54% 629 26.80% 73.20% 8.83% 49.71% 14.61%
565 29.76% 70.24% 8.67% 47.95% 13.56% 630 26.75% 73.25% 8.83% 49.73% 14.63%
566 29.71% 70.29% 8.68% 47.98% 13.57% 631 26.71% 73.29% 8.83% 49.77% 14.64%
567 29.67% 70.33% 8.68% 48.00% 13.60% 632 26.66% 73.34% 8.83% 49.80% 14.66%
568 29.62% 70.38% 8.68% 48.03% 13.61% 633 26.61% 73.39% 8.83% 49.83% 14.68%
569 29.57% 70.43% 8.69% 48.06% 13.63% 634 26.57% 73.43% 8.83% 49.86% 14.69%
570 29.53% 70.47% 8.69% 48.08% 13.64% 635 26.52% 73.48% 8.83% 49.89% 14.70%
571 29.47% 70.53% 8.69% 48.11% 13.66% 636 26.49% 73.52% 8.83% 49.91% 14.71%
572 29.43% 70.57% 8.70% 48.13% 13.68% 637 26.46% 73.54% 8.84% 49.92% 14.72%
573 29.39% 70.62% 8.70% 48.16% 13.69% 638 26.43% 73.57% 8.84% 49.95% 14.73%
574 29.35% 70.65% 8.70% 48.18% 13.71% 639 26.38% 73.62% 8.84% 49.98% 14.75%
575 29.30% 70.71% 8.70% 48.22% 13.73% 640 26.34% 73.66% 8.84% 50.00% 14.76%
576 29.25% 70.75% 8.71% 48.24% 13.74% 641 26.29% 73.71% 8.84% 50.04% 14.77%
577 29.20% 70.80% 8.71% 48.27% 13.76% 642 26.25% 73.75% 8.84% 50.06% 14.79%
578 29.15% 70.85% 8.71% 48.30% 13.78% 643 26.20% 73.80% 8.85% 50.09% 14.80%
579 29.09% 70.91% 8.72% 48.34% 13.80% 644 26.18% 73.82% 8.85% 50.11% 14.81%
580 29.03% 70.97% 8.72% 48.38% 13.82% 645 26.13% 73.87% 8.85% 50.14% 14.82%
581 28.99% 71.01% 8.72% 48.40% 13.83% 646 26.09% 73.91% 8.85% 50.17% 14.84%
582 28.95% 71.06% 8.73% 48.43% 13.84% 647 26.05% 73.95% 8.85% 50.18% 14.85%
583 28.89% 71.11% 8.73% 48.47% 13.86% 648 26.01% 73.99% 8.85% 50.21% 14.87%
584 28.84% 71.16% 8.73% 48.50% 13.87% 649 25.96% 74.04% 8.86% 50.25% 14.89%
585 28.80% 71.20% 8.73% 48.53% 13.88% 650 25.92% 74.08% 8.86% 50.27% 14.90%
586 28.75% 71.25% 8.73% 48.56% 13.90% 651 25.87% 74.13% 8.86% 50.30% 14.91%
587 28.71% 71.29% 8.73% 48.59% 13.91% 652 25.83% 74.17% 8.86% 50.33% 14.92%
588 28.67% 71.33% 8.73% 48.61% 13.93% 653 25.80% 74.20% 8.86% 50.35% 14.94%
589 28.63% 71.37% 8.73% 48.64% 13.94% 654 25.76% 74.24% 8.86% 50.38% 14.95%
590 28.58% 71.42% 8.74% 48.67% 13.96% 655 25.71% 74.29% 8.86% 50.42% 14.96%
591 28.53% 71.47% 8.74% 48.70% 13.98% 656 25.67% 74.33% 8.86% 50.44% 14.97%
592 28.47% 71.53% 8.74% 48.73% 14.00% 657 25.63% 74.37% 8.87% 50.46% 14.99%
593 28.43% 71.57% 8.74% 48.76% 14.02% 658 25.59% 74.41% 8.87% 50.49% 15.00%
594 28.39% 71.61% 8.74% 48.78% 14.03% 659 25.56% 74.44% 8.87% 50.51% 15.01%
595 28.34% 71.66% 8.75% 48.82% 14.04% 660 25.52% 74.49% 8.87% 50.53% 15.03%
596 28.30% 71.70% 8.75% 48.84% 14.05% 661 25.47% 74.53% 8.87% 50.56% 15.04%
597 28.23% 71.77% 8.75% 48.88% 14.08% 662 25.44% 74.57% 8.87% 50.58% 15.06%
598 28.19% 71.81% 8.76% 48.91% 14.09% 663 25.39% 74.61% 8.87% 50.61% 15.07%
599 28.16% 71.84% 8.76% 48.93% 14.10% 664 25.36% 74.64% 8.87% 50.63% 15.08%
600 28.12% 71.88% 8.76% 48.95% 14.11% 665 25.32% 74.68% 8.87% 50.65% 15.10%
601 28.08% 71.93% 8.76% 48.98% 14.13% 666 25.29% 74.71% 8.88% 50.67% 15.11%
602 28.03% 71.97% 8.76% 49.00% 14.15% 667 25.25% 74.75% 8.88% 50.69% 15.13%
603 27.98% 72.02% 8.77% 49.02% 14.17% 668 25.20% 74.80% 8.88% 50.72% 15.15%
226
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 669 25.15% 74.85% 8.88% 50.75% 15.16% 734 22.80% 77.20% 8.99% 52.17% 15.98%
670 25.12% 74.89% 8.88% 50.78% 15.16% 735 22.77% 77.23% 8.99% 52.19% 15.99%
671 25.08% 74.92% 8.88% 50.80% 15.18% 736 22.74% 77.26% 9.00% 52.21% 16.00%
672 25.03% 74.97% 8.88% 50.84% 15.20% 737 22.70% 77.30% 9.00% 52.23% 16.01%
673 24.98% 75.02% 8.89% 50.86% 15.21% 738 22.66% 77.34% 9.00% 52.26% 16.02%
674 24.94% 75.06% 8.89% 50.89% 15.23% 739 22.63% 77.37% 9.00% 52.28% 16.04%
675 24.91% 75.10% 8.89% 50.91% 15.24% 740 22.59% 77.41% 9.00% 52.30% 16.05%
676 24.87% 75.13% 8.89% 50.93% 15.25% 741 22.56% 77.44% 9.00% 52.32% 16.06%
677 24.84% 75.16% 8.89% 50.94% 15.27% 742 22.53% 77.48% 9.01% 52.33% 16.08%
678 24.80% 75.20% 8.89% 50.97% 15.28% 743 22.49% 77.51% 9.01% 52.35% 16.10%
679 24.77% 75.23% 8.90% 50.98% 15.30% 744 22.47% 77.53% 9.01% 52.37% 16.10%
680 24.74% 75.26% 8.90% 51.00% 15.30% 745 22.43% 77.57% 9.01% 52.39% 16.11%
681 24.70% 75.31% 8.90% 51.04% 15.31% 746 22.39% 77.61% 9.01% 52.42% 16.13%
682 24.67% 75.33% 8.90% 51.05% 15.32% 747 22.36% 77.65% 9.01% 52.44% 16.14%
683 24.63% 75.37% 8.90% 51.08% 15.33% 748 22.33% 77.67% 9.01% 52.45% 16.15%
684 24.59% 75.41% 8.90% 51.10% 15.35% 749 22.30% 77.70% 9.01% 52.47% 16.16%
685 24.55% 75.45% 8.91% 51.12% 15.36% 750 22.28% 77.72% 9.01% 52.48% 16.17%
686 24.52% 75.48% 8.91% 51.14% 15.37% 751 22.24% 77.76% 9.02% 52.50% 16.18%
687 24.47% 75.53% 8.92% 51.17% 15.39% 752 22.21% 77.79% 9.02% 52.53% 16.19%
688 24.43% 75.57% 8.92% 51.20% 15.40% 753 22.17% 77.83% 9.02% 52.55% 16.21%
689 24.38% 75.62% 8.92% 51.22% 15.42% 754 22.13% 77.87% 9.02% 52.57% 16.22%
690 24.35% 75.66% 8.92% 51.24% 15.44% 755 22.11% 77.90% 9.02% 52.59% 16.23%
691 24.31% 75.69% 8.92% 51.27% 15.44% 756 22.07% 77.93% 9.02% 52.62% 16.24%
692 24.28% 75.73% 8.92% 51.29% 15.45% 757 22.04% 77.96% 9.02% 52.63% 16.25%
693 24.24% 75.77% 8.92% 51.32% 15.47% 758 22.00% 78.00% 9.02% 52.65% 16.27%
694 24.20% 75.80% 8.92% 51.33% 15.48% 759 21.98% 78.02% 9.02% 52.66% 16.28%
695 24.17% 75.83% 8.93% 51.36% 15.49% 760 21.95% 78.05% 9.02% 52.67% 16.30%
696 24.13% 75.87% 8.93% 51.38% 15.51% 761 21.92% 78.08% 9.02% 52.69% 16.31%
697 24.10% 75.91% 8.93% 51.40% 15.52% 762 21.90% 78.11% 9.03% 52.70% 16.32%
698 24.05% 75.95% 8.93% 51.42% 15.54% 763 21.87% 78.14% 9.03% 52.72% 16.33%
699 24.01% 75.99% 8.93% 51.45% 15.55% 764 21.83% 78.17% 9.03% 52.74% 16.35%
700 23.98% 76.02% 8.93% 51.47% 15.56% 765 21.81% 78.19% 9.03% 52.76% 16.35%
701 23.94% 76.06% 8.94% 51.50% 15.57% 766 21.78% 78.23% 9.03% 52.78% 16.36%
702 23.91% 76.09% 8.94% 51.51% 15.58% 767 21.74% 78.26% 9.03% 52.80% 16.37%
703 23.89% 76.11% 8.94% 51.52% 15.59% 768 21.71% 78.29% 9.03% 52.82% 16.38%
704 23.86% 76.15% 8.94% 51.54% 15.61% 769 21.68% 78.32% 9.03% 52.83% 16.40%
705 23.82% 76.18% 8.94% 51.56% 15.62% 770 21.65% 78.35% 9.03% 52.85% 16.41%
706 23.78% 76.22% 8.94% 51.59% 15.63% 771 21.62% 78.38% 9.03% 52.87% 16.42%
707 23.74% 76.26% 8.94% 51.61% 15.64% 772 21.59% 78.41% 9.03% 52.89% 16.43%
708 23.72% 76.28% 8.95% 51.62% 15.65% 773 21.55% 78.45% 9.04% 52.91% 16.44%
709 23.69% 76.31% 8.95% 51.64% 15.67% 774 21.53% 78.47% 9.04% 52.93% 16.45%
710 23.64% 76.36% 8.95% 51.67% 15.68% 775 21.50% 78.51% 9.04% 52.95% 16.46%
711 23.59% 76.41% 8.96% 51.70% 15.69% 776 21.47% 78.53% 9.04% 52.96% 16.47%
712 23.57% 76.43% 8.96% 51.72% 15.70% 777 21.44% 78.56% 9.04% 52.98% 16.49%
713 23.54% 76.46% 8.96% 51.73% 15.72% 778 21.41% 78.59% 9.04% 52.99% 16.50%
714 23.50% 76.50% 8.96% 51.76% 15.73% 779 21.37% 78.63% 9.04% 53.01% 16.52%
715 23.47% 76.54% 8.96% 51.78% 15.74% 780 21.34% 78.66% 9.04% 53.03% 16.53%
716 23.42% 76.58% 8.96% 51.80% 15.75% 781 21.33% 78.67% 9.04% 53.04% 16.53%
717 23.39% 76.61% 8.96% 51.82% 15.77% 782 21.30% 78.71% 9.04% 53.06% 16.55%
718 23.35% 76.65% 8.97% 51.84% 15.78% 783 21.27% 78.74% 9.04% 53.08% 16.56%
719 23.32% 76.68% 8.97% 51.86% 15.79% 784 21.24% 78.77% 9.04% 53.10% 16.57%
720 23.28% 76.72% 8.97% 51.89% 15.81% 785 21.21% 78.79% 9.04% 53.11% 16.58%
721 23.24% 76.76% 8.97% 51.91% 15.82% 786 21.17% 78.83% 9.04% 53.13% 16.59%
722 23.21% 76.79% 8.97% 51.93% 15.83% 787 21.14% 78.86% 9.04% 53.16% 16.60%
723 23.19% 76.81% 8.97% 51.94% 15.84% 788 21.12% 78.88% 9.04% 53.17% 16.61%
724 23.16% 76.84% 8.98% 51.96% 15.85% 789 21.09% 78.91% 9.05% 53.19% 16.63%
725 23.12% 76.88% 8.98% 51.99% 15.86% 790 21.06% 78.94% 9.05% 53.20% 16.63%
726 23.07% 76.93% 8.98% 52.01% 15.88% 791 21.04% 78.96% 9.05% 53.22% 16.64%
727 23.04% 76.96% 8.98% 52.02% 15.89% 792 21.00% 79.00% 9.05% 53.24% 16.65%
728 23.01% 76.99% 8.98% 52.05% 15.90% 793 20.98% 79.02% 9.05% 53.26% 16.66%
729 22.98% 77.02% 8.99% 52.06% 15.92% 794 20.94% 79.06% 9.05% 53.28% 16.68%
730 22.94% 77.07% 8.99% 52.09% 15.93% 795 20.90% 79.10% 9.05% 53.30% 16.69%
731 22.91% 77.09% 8.99% 52.11% 15.94% 796 20.88% 79.12% 9.05% 53.32% 16.70%
732 22.87% 77.13% 8.99% 52.13% 15.95% 797 20.85% 79.16% 9.05% 53.33% 16.71%
733 22.84% 77.16% 8.99% 52.15% 15.96% 798 20.82% 79.18% 9.05% 53.35% 16.72%
227
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 799 20.79% 79.21% 9.05% 53.36% 16.74% 864 19.02% 80.98% 9.10% 54.40% 17.43%
800 20.76% 79.24% 9.05% 53.39% 16.75% 865 19.00% 81.00% 9.10% 54.41% 17.44%
801 20.72% 79.28% 9.06% 53.41% 16.76% 866 18.98% 81.02% 9.10% 54.42% 17.45%
802 20.69% 79.31% 9.06% 53.43% 16.77% 867 18.94% 81.06% 9.10% 54.44% 17.46%
803 20.67% 79.33% 9.06% 53.44% 16.78% 868 18.91% 81.09% 9.10% 54.46% 17.47%
804 20.65% 79.35% 9.06% 53.45% 16.79% 869 18.89% 81.11% 9.10% 54.47% 17.48%
805 20.63% 79.38% 9.06% 53.47% 16.80% 870 18.86% 81.14% 9.10% 54.49% 17.49%
806 20.60% 79.40% 9.06% 53.48% 16.80% 871 18.83% 81.17% 9.10% 54.51% 17.50%
807 20.57% 79.43% 9.06% 53.50% 16.81% 872 18.81% 81.19% 9.10% 54.53% 17.50%
808 20.54% 79.46% 9.06% 53.52% 16.83% 873 18.79% 81.21% 9.10% 54.54% 17.52%
809 20.51% 79.50% 9.06% 53.54% 16.84% 874 18.77% 81.23% 9.10% 54.55% 17.52%
810 20.48% 79.52% 9.06% 53.56% 16.85% 875 18.74% 81.26% 9.10% 54.57% 17.53%
811 20.45% 79.56% 9.06% 53.58% 16.86% 876 18.71% 81.29% 9.10% 54.59% 17.54%
812 20.41% 79.59% 9.06% 53.59% 16.88% 877 18.68% 81.32% 9.10% 54.61% 17.55%
813 20.38% 79.62% 9.06% 53.61% 16.89% 878 18.67% 81.34% 9.10% 54.62% 17.56%
814 20.36% 79.65% 9.06% 53.62% 16.90% 879 18.64% 81.36% 9.10% 54.64% 17.57%
815 20.32% 79.68% 9.06% 53.64% 16.92% 880 18.62% 81.38% 9.10% 54.65% 17.58%
816 20.29% 79.71% 9.07% 53.66% 16.93% 881 18.60% 81.40% 9.10% 54.65% 17.59%
817 20.26% 79.74% 9.07% 53.67% 16.94% 882 18.58% 81.42% 9.10% 54.66% 17.60%
818 20.23% 79.77% 9.07% 53.69% 16.95% 883 18.56% 81.44% 9.10% 54.67% 17.61%
819 20.20% 79.80% 9.07% 53.71% 16.96% 884 18.54% 81.47% 9.10% 54.68% 17.62%
820 20.17% 79.83% 9.07% 53.73% 16.97% 885 18.51% 81.49% 9.11% 54.70% 17.62%
821 20.15% 79.86% 9.07% 53.75% 16.99% 886 18.49% 81.52% 9.11% 54.71% 17.64%
822 20.12% 79.88% 9.07% 53.76% 16.99% 887 18.45% 81.55% 9.11% 54.73% 17.66%
823 20.10% 79.90% 9.07% 53.77% 17.00% 888 18.43% 81.57% 9.11% 54.75% 17.66%
824 20.07% 79.93% 9.07% 53.79% 17.01% 889 18.40% 81.60% 9.11% 54.76% 17.68%
825 20.04% 79.96% 9.07% 53.80% 17.03% 890 18.38% 81.62% 9.11% 54.77% 17.68%
826 20.01% 80.00% 9.07% 53.82% 17.04% 891 18.36% 81.65% 9.11% 54.79% 17.69%
827 19.98% 80.02% 9.07% 53.83% 17.05% 892 18.33% 81.67% 9.11% 54.80% 17.70%
828 19.96% 80.04% 9.07% 53.85% 17.07% 893 18.30% 81.70% 9.11% 54.82% 17.71%
829 19.94% 80.07% 9.07% 53.86% 17.08% 894 18.28% 81.72% 9.11% 54.84% 17.72%
830 19.90% 80.10% 9.08% 53.88% 17.09% 895 18.25% 81.75% 9.11% 54.85% 17.73%
831 19.87% 80.14% 9.08% 53.90% 17.10% 896 18.23% 81.78% 9.11% 54.87% 17.74%
832 19.84% 80.16% 9.08% 53.92% 17.11% 897 18.20% 81.80% 9.11% 54.89% 17.75%
833 19.81% 80.19% 9.08% 53.93% 17.12% 898 18.16% 81.84% 9.11% 54.91% 17.76%
834 19.79% 80.21% 9.08% 53.94% 17.13% 899 18.14% 81.87% 9.11% 54.93% 17.77%
835 19.77% 80.24% 9.08% 53.96% 17.14% 900 18.12% 81.89% 9.11% 54.94% 17.78%
836 19.74% 80.26% 9.08% 53.98% 17.15% 901 18.09% 81.91% 9.11% 54.95% 17.79%
837 19.71% 80.29% 9.08% 53.99% 17.17% 902 18.06% 81.94% 9.11% 54.97% 17.80%
838 19.68% 80.32% 9.08% 54.00% 17.18% 903 18.04% 81.96% 9.11% 54.98% 17.81%
839 19.66% 80.34% 9.08% 54.01% 17.18% 904 18.02% 81.98% 9.11% 55.00% 17.81%
840 19.63% 80.37% 9.08% 54.03% 17.19% 905 17.99% 82.01% 9.11% 55.02% 17.83%
841 19.61% 80.39% 9.08% 54.06% 17.20% 906 17.96% 82.04% 9.11% 55.03% 17.84%
842 19.58% 80.42% 9.08% 54.07% 17.21% 907 17.93% 82.07% 9.12% 55.05% 17.85%
843 19.56% 80.44% 9.08% 54.08% 17.21% 908 17.91% 82.09% 9.12% 55.06% 17.86%
844 19.54% 80.46% 9.08% 54.10% 17.22% 909 17.88% 82.12% 9.12% 55.08% 17.87%
845 19.52% 80.48% 9.08% 54.11% 17.24% 910 17.86% 82.14% 9.12% 55.09% 17.88%
846 19.49% 80.51% 9.09% 54.13% 17.24% 911 17.85% 82.15% 9.12% 55.10% 17.88%
847 19.47% 80.53% 9.09% 54.14% 17.25% 912 17.83% 82.17% 9.12% 55.11% 17.89%
848 19.43% 80.57% 9.09% 54.16% 17.26% 913 17.80% 82.20% 9.12% 55.13% 17.90%
849 19.40% 80.60% 9.09% 54.18% 17.27% 914 17.78% 82.22% 9.12% 55.14% 17.91%
850 19.38% 80.62% 9.09% 54.19% 17.28% 915 17.75% 82.25% 9.12% 55.16% 17.92%
851 19.35% 80.65% 9.09% 54.21% 17.29% 916 17.73% 82.27% 9.12% 55.17% 17.93%
852 19.33% 80.68% 9.09% 54.22% 17.31% 917 17.71% 82.29% 9.12% 55.18% 17.94%
853 19.30% 80.70% 9.09% 54.23% 17.32% 918 17.68% 82.32% 9.12% 55.20% 17.95%
854 19.28% 80.72% 9.10% 54.24% 17.32% 919 17.65% 82.35% 9.12% 55.21% 17.96%
855 19.26% 80.74% 9.10% 54.26% 17.33% 920 17.63% 82.38% 9.12% 55.23% 17.97%
856 19.23% 80.77% 9.10% 54.27% 17.34% 921 17.61% 82.39% 9.12% 55.23% 17.98%
857 19.20% 80.80% 9.10% 54.28% 17.36% 922 17.58% 82.43% 9.12% 55.26% 17.99%
858 19.18% 80.82% 9.10% 54.30% 17.37% 923 17.56% 82.44% 9.12% 55.27% 17.99%
859 19.15% 80.85% 9.10% 54.32% 17.38% 924 17.54% 82.46% 9.13% 55.28% 18.00%
860 19.12% 80.88% 9.10% 54.33% 17.40% 925 17.51% 82.49% 9.13% 55.29% 18.01%
861 19.09% 80.91% 9.10% 54.34% 17.41% 926 17.49% 82.51% 9.13% 55.31% 18.02%
862 19.07% 80.93% 9.10% 54.36% 17.42% 927 17.47% 82.54% 9.13% 55.32% 18.03%
863 19.05% 80.95% 9.10% 54.37% 17.43% 928 17.45% 82.55% 9.13% 55.33% 18.04%
228
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 929 17.42% 82.58% 9.13% 55.35% 18.05% 994 16.04% 83.96% 9.15% 56.13% 18.62%
930 17.39% 82.61% 9.13% 55.37% 18.06% 995 16.02% 83.98% 9.15% 56.14% 18.63%
931 17.38% 82.62% 9.13% 55.37% 18.07% 996 16.00% 84.00% 9.15% 56.16% 18.64%
932 17.35% 82.65% 9.13% 55.38% 18.08% 997 15.99% 84.01% 9.15% 56.16% 18.64%
933 17.32% 82.68% 9.13% 55.40% 18.09% 998 15.97% 84.03% 9.15% 56.17% 18.65%
934 17.29% 82.71% 9.13% 55.42% 18.10% 999 15.95% 84.05% 9.15% 56.19% 18.66%
935 17.26% 82.74% 9.13% 55.44% 18.11% 1000 15.93% 84.07% 9.15% 56.20% 18.67%
936 17.25% 82.76% 9.13% 55.45% 18.12% 1001 15.91% 84.09% 9.15% 56.22% 18.67%
937 17.22% 82.78% 9.13% 55.47% 18.13% 1002 15.89% 84.11% 9.15% 56.22% 18.68%
938 17.20% 82.80% 9.13% 55.48% 18.14% 1003 15.87% 84.13% 9.15% 56.24% 18.68%
939 17.17% 82.83% 9.13% 55.50% 18.15% 1004 15.85% 84.15% 9.15% 56.25% 18.69%
940 17.15% 82.86% 9.13% 55.51% 18.16% 1005 15.83% 84.17% 9.15% 56.27% 18.70%
941 17.12% 82.88% 9.13% 55.52% 18.17% 1006 15.80% 84.20% 9.15% 56.28% 18.71%
942 17.09% 82.91% 9.13% 55.54% 18.18% 1007 15.78% 84.22% 9.15% 56.29% 18.72%
943 17.08% 82.92% 9.13% 55.54% 18.19% 1008 15.76% 84.24% 9.15% 56.31% 18.72%
944 17.06% 82.94% 9.13% 55.55% 18.19% 1009 15.75% 84.26% 9.15% 56.31% 18.73%
945 17.05% 82.95% 9.13% 55.56% 18.20% 1010 15.73% 84.27% 9.15% 56.33% 18.74%
946 17.03% 82.97% 9.13% 55.58% 18.20% 1011 15.71% 84.29% 9.15% 56.34% 18.74%
947 17.01% 83.00% 9.13% 55.59% 18.21% 1012 15.69% 84.31% 9.15% 56.35% 18.75%
948 16.98% 83.02% 9.13% 55.60% 18.23% 1013 15.67% 84.33% 9.15% 56.37% 18.75%
949 16.96% 83.04% 9.13% 55.62% 18.23% 1014 15.66% 84.34% 9.15% 56.38% 18.75%
950 16.94% 83.06% 9.13% 55.63% 18.24% 1015 15.63% 84.37% 9.15% 56.39% 18.77%
951 16.92% 83.09% 9.14% 55.64% 18.25% 1016 15.62% 84.38% 9.15% 56.40% 18.77%
952 16.89% 83.11% 9.14% 55.65% 18.27% 1017 15.60% 84.40% 9.15% 56.41% 18.78%
953 16.86% 83.14% 9.14% 55.66% 18.28% 1018 15.58% 84.42% 9.15% 56.42% 18.79%
954 16.84% 83.16% 9.14% 55.68% 18.29% 1019 15.56% 84.44% 9.15% 56.44% 18.80%
955 16.82% 83.19% 9.14% 55.70% 18.29% 1020 15.55% 84.45% 9.15% 56.44% 18.80%
956 16.78% 83.22% 9.14% 55.71% 18.31% 1021 15.53% 84.47% 9.15% 56.46% 18.81%
957 16.76% 83.24% 9.14% 55.73% 18.32% 1022 15.51% 84.49% 9.15% 56.46% 18.81%
958 16.75% 83.26% 9.14% 55.73% 18.33% 1023 15.50% 84.50% 9.15% 56.47% 18.82%
959 16.73% 83.27% 9.14% 55.74% 18.34% 1024 15.48% 84.52% 9.15% 56.49% 18.83%
960 16.71% 83.29% 9.14% 55.75% 18.34% 1025 15.46% 84.54% 9.15% 56.50% 18.83%
961 16.69% 83.31% 9.14% 55.76% 18.35% 1026 15.45% 84.55% 9.15% 56.50% 18.84%
962 16.67% 83.33% 9.14% 55.77% 18.36% 1027 15.43% 84.57% 9.15% 56.51% 18.85%
963 16.66% 83.34% 9.14% 55.78% 18.37% 1028 15.41% 84.59% 9.15% 56.53% 18.85%
964 16.64% 83.36% 9.14% 55.79% 18.37% 1029 15.38% 84.62% 9.15% 56.55% 18.86%
965 16.61% 83.39% 9.14% 55.80% 18.39% 1030 15.36% 84.64% 9.15% 56.56% 18.87%
966 16.59% 83.41% 9.14% 55.81% 18.39% 1031 15.35% 84.65% 9.15% 56.57% 18.87%
967 16.58% 83.43% 9.14% 55.83% 18.40% 1032 15.33% 84.68% 9.15% 56.58% 18.88%
968 16.56% 83.44% 9.14% 55.84% 18.40% 1033 15.31% 84.69% 9.15% 56.59% 18.89%
969 16.53% 83.48% 9.14% 55.86% 18.42% 1034 15.28% 84.72% 9.15% 56.61% 18.90%
970 16.50% 83.50% 9.14% 55.87% 18.43% 1035 15.27% 84.73% 9.16% 56.61% 18.91%
971 16.48% 83.52% 9.14% 55.88% 18.44% 1036 15.25% 84.75% 9.16% 56.62% 18.92%
972 16.46% 83.54% 9.14% 55.89% 18.44% 1037 15.22% 84.78% 9.16% 56.63% 18.93%
973 16.44% 83.56% 9.14% 55.90% 18.45% 1038 15.21% 84.79% 9.16% 56.64% 18.94%
974 16.42% 83.59% 9.14% 55.92% 18.46% 1039 15.19% 84.81% 9.16% 56.65% 18.95%
975 16.40% 83.60% 9.14% 55.93% 18.47% 1040 15.18% 84.83% 9.16% 56.66% 18.95%
976 16.38% 83.62% 9.14% 55.94% 18.48% 1041 15.14% 84.86% 9.16% 56.68% 18.97%
977 16.37% 83.63% 9.14% 55.95% 18.48% 1042 15.12% 84.88% 9.16% 56.69% 18.97%
978 16.36% 83.65% 9.14% 55.95% 18.49% 1043 15.10% 84.90% 9.16% 56.70% 18.98%
979 16.34% 83.66% 9.14% 55.97% 18.50% 1044 15.09% 84.91% 9.16% 56.71% 18.99%
980 16.31% 83.69% 9.14% 55.97% 18.51% 1045 15.07% 84.93% 9.16% 56.72% 19.00%
981 16.30% 83.70% 9.14% 55.99% 18.52% 1046 15.06% 84.95% 9.16% 56.73% 19.00%
982 16.28% 83.72% 9.14% 56.00% 18.52% 1047 15.03% 84.97% 9.16% 56.74% 19.01%
983 16.26% 83.74% 9.15% 56.01% 18.53% 1048 15.01% 84.99% 9.16% 56.76% 19.01%
984 16.24% 83.76% 9.15% 56.02% 18.54% 1049 14.98% 85.02% 9.16% 56.78% 19.03%
985 16.22% 83.78% 9.15% 56.03% 18.54% 1050 14.97% 85.03% 9.16% 56.79% 19.03%
986 16.20% 83.81% 9.15% 56.05% 18.56% 1051 14.95% 85.05% 9.16% 56.80% 19.04%
987 16.18% 83.82% 9.15% 56.05% 18.57% 1052 14.93% 85.07% 9.16% 56.81% 19.04%
988 16.16% 83.84% 9.15% 56.06% 18.57% 1053 14.91% 85.09% 9.16% 56.83% 19.05%
989 16.14% 83.86% 9.15% 56.08% 18.58% 1054 14.90% 85.10% 9.16% 56.84% 19.05%
990 16.12% 83.88% 9.15% 56.09% 18.59% 1055 14.88% 85.12% 9.16% 56.85% 19.06%
991 16.09% 83.91% 9.15% 56.11% 18.60% 1056 14.86% 85.14% 9.16% 56.86% 19.07%
992 16.08% 83.93% 9.15% 56.12% 18.60% 1057 14.84% 85.16% 9.16% 56.87% 19.08%
993 16.06% 83.94% 9.15% 56.12% 18.61% 1058 14.82% 85.18% 9.16% 56.88% 19.08%
229
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 1059 14.80% 85.20% 9.16% 56.89% 19.10% 1124 13.68% 86.32% 9.17% 57.56% 19.53%
1060 14.78% 85.22% 9.16% 56.90% 19.10% 1125 13.67% 86.33% 9.17% 57.57% 19.54%
1061 14.76% 85.24% 9.16% 56.91% 19.11% 1126 13.64% 86.36% 9.17% 57.58% 19.55%
1062 14.74% 85.26% 9.16% 56.93% 19.11% 1127 13.63% 86.37% 9.17% 57.59% 19.56%
1063 14.73% 85.27% 9.16% 56.94% 19.12% 1128 13.62% 86.38% 9.17% 57.60% 19.56%
1064 14.72% 85.29% 9.16% 56.95% 19.12% 1129 13.60% 86.40% 9.17% 57.61% 19.57%
1065 14.70% 85.30% 9.16% 56.95% 19.13% 1130 13.59% 86.41% 9.17% 57.62% 19.57%
1066 14.68% 85.32% 9.16% 56.96% 19.14% 1131 13.57% 86.43% 9.17% 57.62% 19.58%
1067 14.66% 85.34% 9.16% 56.98% 19.14% 1132 13.56% 86.44% 9.17% 57.63% 19.59%
1068 14.65% 85.35% 9.16% 56.99% 19.15% 1133 13.54% 86.46% 9.17% 57.64% 19.59%
1069 14.64% 85.36% 9.16% 57.00% 19.15% 1134 13.52% 86.48% 9.17% 57.65% 19.60%
1070 14.62% 85.38% 9.16% 57.01% 19.15% 1135 13.50% 86.50% 9.17% 57.66% 19.61%
1071 14.60% 85.40% 9.16% 57.02% 19.16% 1136 13.49% 86.52% 9.17% 57.67% 19.62%
1072 14.59% 85.41% 9.16% 57.02% 19.17% 1137 13.48% 86.53% 9.17% 57.68% 19.62%
1073 14.56% 85.44% 9.16% 57.04% 19.18% 1138 13.46% 86.54% 9.17% 57.68% 19.63%
1074 14.55% 85.45% 9.16% 57.05% 19.19% 1139 13.45% 86.56% 9.17% 57.69% 19.64%
1075 14.53% 85.47% 9.16% 57.06% 19.20% 1140 13.43% 86.57% 9.17% 57.70% 19.64%
1076 14.51% 85.49% 9.16% 57.07% 19.21% 1141 13.41% 86.59% 9.17% 57.72% 19.65%
1077 14.49% 85.52% 9.16% 57.08% 19.22% 1142 13.39% 86.61% 9.17% 57.73% 19.65%
1078 14.46% 85.54% 9.16% 57.09% 19.22% 1143 13.38% 86.62% 9.17% 57.73% 19.66%
1079 14.45% 85.55% 9.16% 57.10% 19.23% 1144 13.36% 86.64% 9.17% 57.75% 19.67%
1080 14.42% 85.58% 9.16% 57.11% 19.24% 1145 13.34% 86.66% 9.17% 57.76% 19.67%
1081 14.41% 85.59% 9.16% 57.12% 19.25% 1146 13.32% 86.68% 9.17% 57.77% 19.68%
1082 14.39% 85.61% 9.16% 57.13% 19.26% 1147 13.31% 86.69% 9.17% 57.77% 19.68%
1083 14.38% 85.63% 9.16% 57.14% 19.27% 1148 13.29% 86.71% 9.17% 57.79% 19.69%
1084 14.36% 85.64% 9.16% 57.15% 19.27% 1149 13.27% 86.73% 9.17% 57.80% 19.70%
1085 14.34% 85.66% 9.16% 57.16% 19.28% 1150 13.26% 86.74% 9.17% 57.80% 19.71%
1086 14.32% 85.68% 9.16% 57.17% 19.29% 1151 13.25% 86.75% 9.17% 57.81% 19.71%
1087 14.30% 85.70% 9.16% 57.18% 19.30% 1152 13.24% 86.76% 9.17% 57.82% 19.72%
1088 14.28% 85.72% 9.17% 57.19% 19.30% 1153 13.22% 86.78% 9.17% 57.82% 19.73%
1089 14.27% 85.73% 9.17% 57.20% 19.31% 1154 13.21% 86.79% 9.17% 57.83% 19.73%
1090 14.25% 85.75% 9.17% 57.21% 19.31% 1155 13.20% 86.80% 9.17% 57.84% 19.74%
1091 14.24% 85.76% 9.17% 57.22% 19.32% 1156 13.19% 86.81% 9.17% 57.84% 19.74%
1092 14.22% 85.78% 9.17% 57.23% 19.33% 1157 13.17% 86.83% 9.17% 57.85% 19.75%
1093 14.21% 85.79% 9.17% 57.23% 19.33% 1158 13.15% 86.85% 9.17% 57.86% 19.76%
1094 14.19% 85.81% 9.17% 57.25% 19.34% 1159 13.14% 86.86% 9.17% 57.87% 19.76%
1095 14.17% 85.83% 9.17% 57.26% 19.35% 1160 13.13% 86.88% 9.17% 57.88% 19.77%
1096 14.16% 85.84% 9.17% 57.27% 19.35% 1161 13.11% 86.89% 9.17% 57.88% 19.78%
1097 14.15% 85.85% 9.17% 57.27% 19.36% 1162 13.10% 86.90% 9.17% 57.89% 19.78%
1098 14.13% 85.87% 9.17% 57.28% 19.36% 1163 13.09% 86.91% 9.17% 57.90% 19.79%
1099 14.11% 85.89% 9.17% 57.30% 19.37% 1164 13.07% 86.93% 9.17% 57.91% 19.79%
1100 14.10% 85.90% 9.17% 57.30% 19.37% 1165 13.06% 86.94% 9.17% 57.92% 19.79%
1101 14.08% 85.92% 9.17% 57.32% 19.38% 1166 13.05% 86.95% 9.17% 57.92% 19.80%
1102 14.07% 85.93% 9.17% 57.33% 19.38% 1167 13.03% 86.97% 9.17% 57.93% 19.80%
1103 14.05% 85.95% 9.17% 57.34% 19.39% 1168 13.01% 86.99% 9.17% 57.95% 19.81%
1104 14.03% 85.97% 9.17% 57.35% 19.40% 1169 13.01% 86.99% 9.17% 57.95% 19.81%
1105 14.01% 85.99% 9.17% 57.36% 19.41% 1170 13.00% 87.00% 9.17% 57.96% 19.82%
1106 13.99% 86.01% 9.17% 57.36% 19.42% 1171 12.98% 87.02% 9.17% 57.96% 19.83%
1107 13.98% 86.02% 9.17% 57.37% 19.42% 1172 12.97% 87.03% 9.17% 57.97% 19.84%
1108 13.96% 86.04% 9.17% 57.39% 19.43% 1173 12.95% 87.05% 9.17% 57.98% 19.85%
1109 13.94% 86.06% 9.17% 57.40% 19.44% 1174 12.94% 87.06% 9.17% 57.98% 19.85%
1110 13.92% 86.08% 9.17% 57.41% 19.44% 1175 12.93% 87.07% 9.17% 57.99% 19.86%
1111 13.90% 86.10% 9.17% 57.42% 19.45% 1176 12.92% 87.08% 9.17% 57.99% 19.86%
1112 13.89% 86.11% 9.17% 57.43% 19.46% 1177 12.91% 87.09% 9.17% 58.00% 19.86%
1113 13.87% 86.13% 9.17% 57.44% 19.46% 1178 12.90% 87.11% 9.17% 58.01% 19.87%
1114 13.86% 86.14% 9.17% 57.45% 19.47% 1179 12.88% 87.12% 9.17% 58.02% 19.87%
1115 13.84% 86.16% 9.17% 57.46% 19.47% 1180 12.87% 87.13% 9.17% 58.02% 19.88%
1116 13.82% 86.18% 9.17% 57.48% 19.48% 1181 12.85% 87.15% 9.17% 58.03% 19.89%
1117 13.80% 86.20% 9.17% 57.49% 19.49% 1182 12.84% 87.16% 9.17% 58.04% 19.90%
1118 13.79% 86.22% 9.17% 57.49% 19.50% 1183 12.81% 87.19% 9.17% 58.05% 19.91%
1119 13.77% 86.23% 9.17% 57.51% 19.50% 1184 12.80% 87.20% 9.17% 58.06% 19.91%
1120 13.76% 86.24% 9.17% 57.51% 19.51% 1185 12.79% 87.21% 9.17% 58.07% 19.91%
1121 13.74% 86.26% 9.17% 57.53% 19.51% 1186 12.77% 87.23% 9.17% 58.09% 19.91%
1122 13.72% 86.28% 9.17% 57.54% 19.52% 1187 12.76% 87.24% 9.17% 58.09% 19.92%
1123 13.70% 86.30% 9.17% 57.55% 19.53% 1188 12.74% 87.26% 9.17% 58.10% 19.93%
230
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 1189 12.72% 87.28% 9.17% 58.11% 19.94%
1190 12.71% 87.29% 9.17% 58.12% 19.94%
1191 12.70% 87.30% 9.17% 58.13% 19.94%
1192 12.69% 87.32% 9.17% 58.14% 19.94%
1193 12.66% 87.34% 9.17% 58.15% 19.96%
1194 12.64% 87.36% 9.17% 58.16% 19.96%
1195 12.62% 87.38% 9.17% 58.18% 19.97%
1196 12.60% 87.40% 9.17% 58.19% 19.98%
1197 12.59% 87.42% 9.17% 58.20% 19.99%
1198 12.57% 87.44% 9.17% 58.21% 19.99%
1199 12.55% 87.46% 9.17% 58.22% 20.00%
1200 12.53% 87.47% 9.17% 58.23% 20.01%
231
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA
-306 98.37% 1.63% 1.63% 0.00% 0.00%
-305 98.36% 1.64% 1.64% 0.00% 0.00%
Table B8. LOCA Probability History for ASP-07 -304 98.34% 1.66% 1.66% 0.00% 0.00%
for Days After TOD -303 98.33% 1.67% 1.67% 0.00% 0.00%
-302 98.31% 1.69% 1.69% 0.00% 0.00%
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA -301 98.29% 1.71% 1.71% 0.00% 0.00%
-365 98.97% 1.03% 1.03% 0.00% 0.00% -300 98.28% 1.72% 1.72% 0.00% 0.00%
-364 98.96% 1.04% 1.04% 0.00% 0.00% -299 98.27% 1.73% 1.73% 0.00% 0.00%
-363 98.96% 1.04% 1.04% 0.00% 0.00% -298 98.26% 1.74% 1.74% 0.00% 0.00%
-362 98.94% 1.06% 1.06% 0.00% 0.00% -297 98.24% 1.76% 1.76% 0.00% 0.00%
-361 98.94% 1.07% 1.07% 0.00% 0.00% -296 98.23% 1.77% 1.77% 0.00% 0.00%
-360 98.93% 1.07% 1.07% 0.00% 0.00% -295 98.22% 1.78% 1.78% 0.00% 0.00%
-359 98.92% 1.08% 1.08% 0.00% 0.00% -294 98.21% 1.79% 1.79% 0.00% 0.00%
-358 98.91% 1.09% 1.09% 0.00% 0.00% -293 98.20% 1.80% 1.80% 0.00% 0.00%
-357 98.90% 1.10% 1.10% 0.00% 0.00% -292 98.18% 1.82% 1.82% 0.00% 0.00%
-356 98.90% 1.11% 1.11% 0.00% 0.00% -291 98.16% 1.84% 1.84% 0.00% 0.00%
-355 98.89% 1.11% 1.11% 0.00% 0.00% -290 98.14% 1.86% 1.86% 0.00% 0.00%
-354 98.88% 1.12% 1.12% 0.00% 0.00% -289 98.12% 1.89% 1.88% 0.00% 0.00%
-353 98.87% 1.13% 1.13% 0.00% 0.00% -288 98.09% 1.91% 1.91% 0.00% 0.00%
-352 98.86% 1.14% 1.14% 0.00% 0.00% -287 98.07% 1.93% 1.93% 0.00% 0.00%
-351 98.86% 1.14% 1.14% 0.00% 0.00% -286 98.06% 1.94% 1.94% 0.00% 0.00%
-350 98.85% 1.15% 1.15% 0.00% 0.00% -285 98.04% 1.96% 1.96% 0.00% 0.00%
-349 98.84% 1.16% 1.16% 0.00% 0.00% -284 98.02% 1.98% 1.98% 0.00% 0.00%
-348 98.83% 1.17% 1.17% 0.00% 0.00% -283 98.01% 1.99% 1.99% 0.00% 0.00%
-347 98.82% 1.19% 1.19% 0.00% 0.00% -282 98.00% 2.01% 2.00% 0.00% 0.00%
-346 98.80% 1.20% 1.20% 0.00% 0.00% -281 97.97% 2.03% 2.03% 0.00% 0.00%
-345 98.79% 1.21% 1.21% 0.00% 0.00% -280 97.95% 2.05% 2.05% 0.00% 0.00%
-344 98.79% 1.21% 1.21% 0.00% 0.00% -279 97.94% 2.06% 2.06% 0.00% 0.00%
-343 98.78% 1.22% 1.22% 0.00% 0.00% -278 97.92% 2.08% 2.08% 0.00% 0.00%
-342 98.76% 1.24% 1.24% 0.00% 0.00% -277 97.91% 2.09% 2.09% 0.00% 0.00%
-341 98.75% 1.25% 1.25% 0.00% 0.00% -276 97.89% 2.11% 2.11% 0.00% 0.00%
-340 98.74% 1.26% 1.26% 0.00% 0.00% -275 97.87% 2.13% 2.13% 0.00% 0.00%
-339 98.73% 1.27% 1.27% 0.00% 0.00% -274 97.86% 2.14% 2.14% 0.00% 0.00%
-338 98.72% 1.28% 1.28% 0.00% 0.00% -273 97.84% 2.16% 2.16% 0.00% 0.00%
-337 98.72% 1.28% 1.28% 0.00% 0.00% -272 97.82% 2.18% 2.17% 0.00% 0.00%
-336 98.71% 1.29% 1.29% 0.00% 0.00% -271 97.82% 2.18% 2.18% 0.00% 0.00%
-335 98.69% 1.31% 1.31% 0.00% 0.00% -270 97.81% 2.19% 2.19% 0.00% 0.00%
-334 98.68% 1.32% 1.32% 0.00% 0.00% -269 97.78% 2.22% 2.21% 0.00% 0.00%
-333 98.67% 1.33% 1.33% 0.00% 0.00% -268 97.77% 2.23% 2.23% 0.00% 0.00%
-332 98.66% 1.34% 1.34% 0.00% 0.00% -267 97.76% 2.24% 2.24% 0.00% 0.00%
-331 98.65% 1.35% 1.35% 0.00% 0.00% -266 97.74% 2.27% 2.26% 0.00% 0.00%
-330 98.64% 1.36% 1.36% 0.00% 0.00% -265 97.72% 2.28% 2.28% 0.00% 0.00%
-329 98.64% 1.36% 1.36% 0.00% 0.00% -264 97.70% 2.30% 2.30% 0.00% 0.00%
-328 98.63% 1.38% 1.38% 0.00% 0.00% -263 97.68% 2.32% 2.32% 0.00% 0.00%
-327 98.61% 1.39% 1.39% 0.00% 0.00% -262 97.66% 2.34% 2.34% 0.00% 0.00%
-326 98.60% 1.40% 1.40% 0.00% 0.00% -261 97.63% 2.37% 2.36% 0.00% 0.00%
-325 98.59% 1.41% 1.41% 0.00% 0.00% -260 97.61% 2.39% 2.38% 0.00% 0.00%
-324 98.58% 1.42% 1.42% 0.00% 0.00% -259 97.60% 2.40% 2.40% 0.00% 0.00%
-323 98.56% 1.44% 1.44% 0.00% 0.00% -258 97.58% 2.42% 2.42% 0.00% 0.00%
-322 98.56% 1.45% 1.45% 0.00% 0.00% -257 97.55% 2.45% 2.44% 0.00% 0.00%
-321 98.55% 1.45% 1.45% 0.00% 0.00% -256 97.54% 2.46% 2.46% 0.00% 0.00%
-320 98.54% 1.46% 1.46% 0.00% 0.00% -255 97.51% 2.49% 2.48% 0.00% 0.00%
-319 98.53% 1.48% 1.48% 0.00% 0.00% -254 97.49% 2.51% 2.51% 0.01% 0.00%
-318 98.52% 1.48% 1.48% 0.00% 0.00% -253 97.47% 2.53% 2.53% 0.01% 0.00%
-317 98.51% 1.49% 1.49% 0.00% 0.00% -252 97.45% 2.55% 2.55% 0.01% 0.00%
-316 98.50% 1.50% 1.50% 0.00% 0.00% -251 97.43% 2.58% 2.57% 0.01% 0.00%
-315 98.49% 1.51% 1.51% 0.00% 0.00% -250 97.40% 2.61% 2.60% 0.01% 0.00%
-314 98.48% 1.52% 1.52% 0.00% 0.00% -249 97.37% 2.63% 2.62% 0.01% 0.00%
-313 98.47% 1.53% 1.53% 0.00% 0.00% -248 97.34% 2.66% 2.65% 0.01% 0.00%
-312 98.46% 1.55% 1.55% 0.00% 0.00% -247 97.32% 2.68% 2.67% 0.01% 0.00%
-311 98.45% 1.56% 1.56% 0.00% 0.00% -246 97.30% 2.71% 2.70% 0.01% 0.00%
-310 98.44% 1.56% 1.56% 0.00% 0.00% -245 97.28% 2.72% 2.71% 0.01% 0.00%
-309 98.42% 1.59% 1.59% 0.00% 0.00% -244 97.25% 2.75% 2.73% 0.01% 0.00%
-308 98.40% 1.60% 1.60% 0.00% 0.00% -243 97.24% 2.77% 2.75% 0.01% 0.01%
-307 98.38% 1.62% 1.62% 0.00% 0.00% -242 97.21% 2.79% 2.78% 0.01% 0.01%
232
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA
-241 97.19% 2.81% 2.80% 0.01% 0.01% -176 94.73% 5.27% 5.01% 0.09% 0.17%
-240 97.15% 2.85% 2.84% 0.01% 0.01% -175 94.68% 5.32% 5.06% 0.09% 0.18%
-239 97.12% 2.88% 2.86% 0.01% 0.01% -174 94.64% 5.36% 5.09% 0.09% 0.18%
-238 97.09% 2.91% 2.89% 0.01% 0.01% -173 94.58% 5.42% 5.13% 0.09% 0.20%
-237 97.07% 2.93% 2.91% 0.01% 0.01% -172 94.53% 5.48% 5.18% 0.09% 0.21%
-236 97.03% 2.97% 2.94% 0.02% 0.01% -171 94.48% 5.52% 5.22% 0.10% 0.21%
-235 97.00% 3.00% 2.97% 0.02% 0.01% -170 94.43% 5.57% 5.25% 0.10% 0.22%
-234 96.97% 3.04% 3.01% 0.02% 0.01% -169 94.36% 5.64% 5.31% 0.10% 0.23%
-233 96.94% 3.06% 3.03% 0.02% 0.01% -168 94.32% 5.69% 5.35% 0.10% 0.24%
-232 96.91% 3.09% 3.06% 0.02% 0.01% -167 94.26% 5.74% 5.39% 0.10% 0.25%
-231 96.87% 3.13% 3.09% 0.02% 0.01% -166 94.21% 5.79% 5.43% 0.10% 0.26%
-230 96.84% 3.16% 3.13% 0.02% 0.01% -165 94.17% 5.83% 5.46% 0.10% 0.26%
-229 96.81% 3.19% 3.16% 0.02% 0.01% -164 94.13% 5.87% 5.50% 0.10% 0.27%
-228 96.78% 3.22% 3.19% 0.02% 0.02% -163 94.08% 5.93% 5.54% 0.11% 0.28%
-227 96.75% 3.26% 3.22% 0.02% 0.02% -162 94.02% 5.98% 5.58% 0.11% 0.29%
-226 96.71% 3.29% 3.25% 0.02% 0.02% -161 93.96% 6.04% 5.63% 0.11% 0.30%
-225 96.68% 3.32% 3.28% 0.02% 0.02% -160 93.91% 6.09% 5.67% 0.12% 0.31%
-224 96.65% 3.35% 3.30% 0.02% 0.02% -159 93.85% 6.15% 5.70% 0.12% 0.33%
-223 96.62% 3.38% 3.33% 0.03% 0.02% -158 93.79% 6.21% 5.75% 0.12% 0.34%
-222 96.60% 3.40% 3.35% 0.03% 0.02% -157 93.74% 6.26% 5.80% 0.12% 0.34%
-221 96.57% 3.43% 3.38% 0.03% 0.02% -156 93.67% 6.33% 5.86% 0.12% 0.36%
-220 96.54% 3.46% 3.42% 0.03% 0.02% -155 93.60% 6.40% 5.91% 0.12% 0.37%
-219 96.50% 3.50% 3.45% 0.03% 0.02% -154 93.55% 6.45% 5.95% 0.12% 0.38%
-218 96.47% 3.53% 3.47% 0.03% 0.03% -153 93.49% 6.51% 5.99% 0.13% 0.40%
-217 96.44% 3.56% 3.50% 0.03% 0.03% -152 93.43% 6.57% 6.03% 0.13% 0.41%
-216 96.40% 3.61% 3.55% 0.03% 0.03% -151 93.38% 6.62% 6.07% 0.13% 0.43%
-215 96.36% 3.64% 3.57% 0.03% 0.03% -150 93.33% 6.67% 6.10% 0.14% 0.44%
-214 96.33% 3.68% 3.61% 0.04% 0.03% -149 93.27% 6.73% 6.15% 0.14% 0.44%
-213 96.29% 3.71% 3.64% 0.04% 0.04% -148 93.21% 6.80% 6.20% 0.14% 0.46%
-212 96.27% 3.73% 3.66% 0.04% 0.04% -147 93.13% 6.87% 6.26% 0.14% 0.48%
-211 96.23% 3.77% 3.70% 0.04% 0.04% -146 93.06% 6.95% 6.31% 0.14% 0.49%
-210 96.20% 3.81% 3.73% 0.04% 0.04% -145 92.98% 7.03% 6.36% 0.15% 0.51%
-209 96.16% 3.84% 3.76% 0.04% 0.04% -144 92.90% 7.10% 6.42% 0.15% 0.53%
-208 96.12% 3.88% 3.79% 0.05% 0.04% -143 92.82% 7.18% 6.47% 0.15% 0.55%
-207 96.09% 3.91% 3.82% 0.05% 0.04% -142 92.74% 7.26% 6.54% 0.15% 0.57%
-206 96.05% 3.95% 3.86% 0.05% 0.04% -141 92.66% 7.34% 6.59% 0.16% 0.59%
-205 96.01% 3.99% 3.89% 0.05% 0.05% -140 92.60% 7.40% 6.63% 0.16% 0.61%
-204 95.97% 4.03% 3.93% 0.05% 0.05% -139 92.52% 7.48% 6.68% 0.16% 0.64%
-203 95.94% 4.06% 3.96% 0.05% 0.05% -138 92.45% 7.55% 6.73% 0.16% 0.66%
-202 95.89% 4.11% 4.00% 0.05% 0.05% -137 92.38% 7.63% 6.78% 0.17% 0.68%
-201 95.86% 4.14% 4.03% 0.05% 0.06% -136 92.30% 7.70% 6.83% 0.17% 0.69%
-200 95.82% 4.18% 4.06% 0.05% 0.06% -135 92.24% 7.76% 6.88% 0.18% 0.71%
-199 95.78% 4.22% 4.10% 0.06% 0.06% -134 92.17% 7.83% 6.93% 0.18% 0.72%
-198 95.73% 4.27% 4.15% 0.06% 0.07% -133 92.08% 7.92% 6.99% 0.18% 0.74%
-197 95.69% 4.31% 4.19% 0.06% 0.07% -132 92.01% 7.99% 7.05% 0.19% 0.76%
-196 95.64% 4.36% 4.23% 0.06% 0.07% -131 91.94% 8.06% 7.10% 0.19% 0.78%
-195 95.61% 4.39% 4.25% 0.06% 0.07% -130 91.86% 8.14% 7.16% 0.19% 0.79%
-194 95.58% 4.42% 4.29% 0.06% 0.08% -129 91.79% 8.21% 7.20% 0.19% 0.82%
-193 95.54% 4.47% 4.32% 0.06% 0.08% -128 91.72% 8.28% 7.25% 0.19% 0.83%
-192 95.50% 4.51% 4.36% 0.06% 0.08% -127 91.65% 8.35% 7.30% 0.19% 0.85%
-191 95.46% 4.54% 4.39% 0.06% 0.09% -126 91.57% 8.43% 7.37% 0.19% 0.87%
-190 95.41% 4.59% 4.43% 0.07% 0.09% -125 91.48% 8.52% 7.43% 0.20% 0.89%
-189 95.36% 4.64% 4.47% 0.07% 0.10% -124 91.39% 8.61% 7.50% 0.20% 0.91%
-188 95.32% 4.68% 4.51% 0.07% 0.10% -123 91.30% 8.70% 7.56% 0.21% 0.94%
-187 95.28% 4.72% 4.55% 0.07% 0.11% -122 91.22% 8.78% 7.61% 0.21% 0.96%
-186 95.23% 4.77% 4.58% 0.07% 0.11% -121 91.16% 8.85% 7.65% 0.21% 0.98%
-185 95.19% 4.81% 4.63% 0.07% 0.12% -120 91.09% 8.91% 7.70% 0.22% 1.00%
-184 95.14% 4.86% 4.66% 0.07% 0.12% -119 91.01% 8.99% 7.75% 0.22% 1.03%
-183 95.10% 4.90% 4.70% 0.08% 0.13% -118 90.93% 9.07% 7.80% 0.22% 1.06%
-182 95.06% 4.95% 4.74% 0.08% 0.13% -117 90.84% 9.16% 7.85% 0.22% 1.08%
-181 95.01% 4.99% 4.78% 0.08% 0.14% -116 90.77% 9.23% 7.90% 0.23% 1.10%
-180 94.95% 5.05% 4.83% 0.08% 0.14% -115 90.68% 9.32% 7.96% 0.23% 1.13%
-179 94.90% 5.10% 4.87% 0.08% 0.15% -114 90.61% 9.39% 8.01% 0.24% 1.15%
-178 94.85% 5.16% 4.92% 0.08% 0.16% -113 90.52% 9.48% 8.06% 0.24% 1.18%
-177 94.79% 5.21% 4.97% 0.08% 0.16% -112 90.42% 9.58% 8.12% 0.25% 1.22%
233
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA
-111 90.34% 9.66% 8.16% 0.25% 1.25% -46 82.93% 17.07% 12.35% 0.54% 4.18%
-110 90.24% 9.76% 8.22% 0.25% 1.29% -45 82.80% 17.20% 12.42% 0.55% 4.24%
-109 90.14% 9.86% 8.28% 0.26% 1.32% -44 82.65% 17.35% 12.49% 0.55% 4.31%
-108 90.07% 9.93% 8.33% 0.26% 1.34% -43 82.52% 17.49% 12.55% 0.56% 4.38%
-107 89.98% 10.02% 8.38% 0.27% 1.37% -42 82.37% 17.63% 12.63% 0.56% 4.44%
-106 89.90% 10.10% 8.43% 0.27% 1.40% -41 82.24% 17.76% 12.70% 0.56% 4.50%
-105 89.81% 10.19% 8.48% 0.27% 1.44% -40 82.09% 17.91% 12.78% 0.57% 4.56%
-104 89.72% 10.28% 8.54% 0.28% 1.47% -39 81.93% 18.07% 12.87% 0.57% 4.63%
-103 89.62% 10.39% 8.60% 0.28% 1.50% -38 81.80% 18.20% 12.93% 0.58% 4.69%
-102 89.52% 10.48% 8.66% 0.29% 1.54% -37 81.66% 18.34% 13.01% 0.58% 4.75%
-101 89.41% 10.59% 8.73% 0.29% 1.57% -36 81.50% 18.50% 13.08% 0.59% 4.83%
-100 89.31% 10.69% 8.79% 0.29% 1.61% -35 81.34% 18.66% 13.15% 0.59% 4.92%
-99 89.22% 10.78% 8.85% 0.29% 1.64% -34 81.20% 18.80% 13.22% 0.60% 4.98%
-98 89.10% 10.91% 8.92% 0.30% 1.69% -33 81.04% 18.96% 13.30% 0.61% 5.06%
-97 88.99% 11.01% 8.98% 0.31% 1.72% -32 80.87% 19.13% 13.37% 0.61% 5.15%
-96 88.90% 11.10% 9.04% 0.31% 1.75% -31 80.71% 19.29% 13.45% 0.61% 5.23%
-95 88.79% 11.21% 9.11% 0.32% 1.79% -30 80.56% 19.44% 13.53% 0.62% 5.29%
-94 88.68% 11.32% 9.17% 0.32% 1.83% -29 80.39% 19.61% 13.60% 0.63% 5.38%
-93 88.56% 11.44% 9.24% 0.32% 1.88% -28 80.26% 19.74% 13.67% 0.63% 5.44%
-92 88.48% 11.52% 9.29% 0.33% 1.91% -27 80.11% 19.89% 13.74% 0.64% 5.52%
-91 88.38% 11.62% 9.35% 0.34% 1.94% -26 79.95% 20.05% 13.82% 0.64% 5.59%
-90 88.27% 11.73% 9.41% 0.34% 1.98% -25 79.77% 20.23% 13.90% 0.65% 5.68%
-89 88.17% 11.83% 9.47% 0.34% 2.02% -24 79.60% 20.40% 13.99% 0.65% 5.77%
-88 88.08% 11.93% 9.52% 0.35% 2.06% -23 79.46% 20.54% 14.05% 0.65% 5.84%
-87 87.98% 12.02% 9.58% 0.35% 2.09% -22 79.31% 20.69% 14.12% 0.66% 5.91%
-86 87.87% 12.13% 9.64% 0.35% 2.14% -21 79.17% 20.83% 14.20% 0.66% 5.98%
-85 87.78% 12.22% 9.70% 0.35% 2.17% -20 79.00% 21.00% 14.27% 0.66% 6.07%
-84 87.67% 12.33% 9.76% 0.36% 2.21% -19 78.83% 21.17% 14.36% 0.67% 6.15%
-83 87.56% 12.44% 9.83% 0.36% 2.25% -18 78.67% 21.33% 14.43% 0.67% 6.23%
-82 87.46% 12.54% 9.89% 0.37% 2.29% -17 78.50% 21.50% 14.51% 0.68% 6.31%
-81 87.36% 12.65% 9.94% 0.38% 2.33% -16 78.33% 21.67% 14.61% 0.68% 6.38%
-80 87.23% 12.77% 10.01% 0.38% 2.38% -15 78.17% 21.83% 14.68% 0.69% 6.46%
-79 87.12% 12.88% 10.06% 0.38% 2.43% -14 78.01% 21.99% 14.75% 0.70% 6.55%
-78 87.01% 12.99% 10.13% 0.39% 2.47% -13 77.86% 22.14% 14.82% 0.70% 6.62%
-77 86.90% 13.10% 10.19% 0.39% 2.52% -12 77.71% 22.29% 14.88% 0.70% 6.71%
-76 86.76% 13.24% 10.27% 0.40% 2.57% -11 77.55% 22.45% 14.96% 0.71% 6.79%
-75 86.66% 13.35% 10.33% 0.40% 2.61% -10 77.37% 22.64% 15.05% 0.71% 6.87%
-74 86.52% 13.48% 10.41% 0.41% 2.66% -9 77.19% 22.81% 15.13% 0.72% 6.96%
-73 86.41% 13.59% 10.48% 0.41% 2.71% -8 76.99% 23.01% 15.22% 0.72% 7.06%
-72 86.29% 13.71% 10.54% 0.41% 2.76% -7 76.81% 23.19% 15.31% 0.73% 7.15%
-71 86.17% 13.83% 10.60% 0.42% 2.81% -6 76.65% 23.35% 15.39% 0.73% 7.24%
-70 86.05% 13.96% 10.67% 0.42% 2.86% -5 76.46% 23.54% 15.48% 0.73% 7.33%
-69 85.92% 14.08% 10.74% 0.43% 2.91% -4 76.30% 23.70% 15.56% 0.74% 7.40%
-68 85.81% 14.19% 10.80% 0.43% 2.96% -3 76.15% 23.86% 15.62% 0.74% 7.49%
-67 85.69% 14.31% 10.86% 0.44% 3.02% -2 75.99% 24.01% 15.70% 0.75% 7.57%
-66 85.56% 14.44% 10.94% 0.44% 3.07% -1 75.82% 24.18% 15.78% 0.75% 7.65%
-65 85.44% 14.56% 10.99% 0.45% 3.12% 0 75.25% 24.76% 15.87% 0.75% 8.13%
-64 85.34% 14.66% 11.05% 0.45% 3.17% 1 75.08% 24.92% 15.95% 0.76% 8.21%
-63 85.21% 14.79% 11.12% 0.46% 3.21% 2 74.81% 25.20% 16.03% 0.76% 8.40%
-62 85.07% 14.93% 11.20% 0.46% 3.27% 3 74.61% 25.39% 16.09% 0.77% 8.53%
-61 84.96% 15.04% 11.27% 0.46% 3.31% 4 74.43% 25.57% 16.16% 0.78% 8.63%
-60 84.84% 15.16% 11.34% 0.47% 3.35% 5 74.23% 25.77% 16.25% 0.78% 8.73%
-59 84.71% 15.29% 11.41% 0.47% 3.41% 6 74.05% 25.95% 16.34% 0.79% 8.83%
-58 84.58% 15.42% 11.48% 0.48% 3.47% 7 73.85% 26.15% 16.43% 0.80% 8.93%
-57 84.43% 15.57% 11.56% 0.48% 3.53% 8 73.68% 26.32% 16.50% 0.80% 9.01%
-56 84.31% 15.69% 11.62% 0.49% 3.59% 9 73.50% 26.51% 16.59% 0.81% 9.11%
-55 84.17% 15.83% 11.69% 0.49% 3.65% 10 73.34% 26.66% 16.66% 0.81% 9.19%
-54 84.05% 15.95% 11.76% 0.50% 3.70% 11 73.15% 26.85% 16.76% 0.82% 9.27%
-53 83.91% 16.09% 11.82% 0.50% 3.77% 12 72.99% 27.01% 16.83% 0.82% 9.35%
-52 83.77% 16.23% 11.90% 0.51% 3.82% 13 72.82% 27.18% 16.91% 0.83% 9.45%
-51 83.66% 16.34% 11.96% 0.51% 3.86% 14 72.62% 27.38% 17.01% 0.83% 9.54%
-50 83.52% 16.48% 12.04% 0.52% 3.92% 15 72.45% 27.55% 17.10% 0.84% 9.61%
-49 83.37% 16.63% 12.12% 0.53% 3.98% 16 72.24% 27.76% 17.19% 0.85% 9.73%
-48 83.22% 16.78% 12.20% 0.53% 4.06% 17 72.08% 27.92% 17.26% 0.85% 9.81%
-47 83.07% 16.93% 12.27% 0.54% 4.12% 18 71.93% 28.07% 17.33% 0.86% 9.88%
234
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 19 71.72% 28.28% 17.42% 0.86% 10.00% 84 60.47% 39.53% 22.95% 1.21% 15.36%
20 71.54% 28.46% 17.51% 0.87% 10.08% 85 60.33% 39.67% 23.03% 1.22% 15.42%
21 71.36% 28.64% 17.59% 0.87% 10.18% 86 60.17% 39.84% 23.12% 1.23% 15.49%
22 71.18% 28.82% 17.68% 0.87% 10.27% 87 60.01% 39.99% 23.20% 1.23% 15.57%
23 71.01% 29.00% 17.77% 0.88% 10.35% 88 59.85% 40.15% 23.28% 1.24% 15.63%
24 70.83% 29.17% 17.86% 0.88% 10.43% 89 59.71% 40.29% 23.36% 1.24% 15.69%
25 70.63% 29.37% 17.94% 0.89% 10.55% 90 59.56% 40.44% 23.44% 1.25% 15.75%
26 70.44% 29.57% 18.03% 0.89% 10.65% 91 59.39% 40.61% 23.52% 1.26% 15.83%
27 70.26% 29.74% 18.12% 0.90% 10.73% 92 59.22% 40.78% 23.61% 1.26% 15.91%
28 70.07% 29.93% 18.21% 0.90% 10.82% 93 59.07% 40.93% 23.70% 1.27% 15.97%
29 69.89% 30.11% 18.29% 0.90% 10.92% 94 58.89% 41.11% 23.79% 1.27% 16.05%
30 69.71% 30.29% 18.38% 0.91% 11.01% 95 58.73% 41.27% 23.88% 1.27% 16.12%
31 69.52% 30.48% 18.45% 0.92% 11.11% 96 58.56% 41.44% 23.95% 1.28% 16.21%
32 69.33% 30.67% 18.54% 0.92% 11.21% 97 58.39% 41.61% 24.03% 1.29% 16.29%
33 69.14% 30.86% 18.62% 0.93% 11.31% 98 58.22% 41.79% 24.11% 1.30% 16.38%
34 68.96% 31.04% 18.70% 0.94% 11.40% 99 58.04% 41.96% 24.20% 1.30% 16.46%
35 68.79% 31.21% 18.77% 0.95% 11.49% 100 57.88% 42.12% 24.28% 1.31% 16.53%
36 68.64% 31.36% 18.84% 0.95% 11.57% 101 57.73% 42.27% 24.35% 1.32% 16.60%
37 68.46% 31.54% 18.92% 0.96% 11.67% 102 57.56% 42.44% 24.43% 1.32% 16.69%
38 68.28% 31.72% 19.01% 0.96% 11.75% 103 57.40% 42.60% 24.51% 1.33% 16.77%
39 68.12% 31.88% 19.08% 0.96% 11.84% 104 57.24% 42.76% 24.59% 1.33% 16.84%
40 67.94% 32.06% 19.16% 0.97% 11.94% 105 57.09% 42.91% 24.66% 1.34% 16.91%
41 67.75% 32.25% 19.25% 0.97% 12.02% 106 56.94% 43.06% 24.74% 1.35% 16.98%
42 67.56% 32.44% 19.36% 0.97% 12.10% 107 56.76% 43.24% 24.84% 1.35% 17.05%
43 67.39% 32.61% 19.44% 0.98% 12.19% 108 56.60% 43.40% 24.93% 1.35% 17.13%
44 67.22% 32.78% 19.53% 0.98% 12.27% 109 56.41% 43.59% 25.02% 1.36% 17.21%
45 67.04% 32.96% 19.62% 0.99% 12.35% 110 56.26% 43.74% 25.10% 1.36% 17.28%
46 66.84% 33.16% 19.71% 1.00% 12.45% 111 56.10% 43.90% 25.18% 1.37% 17.36%
47 66.64% 33.36% 19.82% 1.01% 12.53% 112 55.94% 44.06% 25.24% 1.38% 17.44%
48 66.45% 33.55% 19.92% 1.01% 12.62% 113 55.78% 44.22% 25.31% 1.38% 17.53%
49 66.30% 33.70% 20.00% 1.01% 12.69% 114 55.63% 44.37% 25.38% 1.38% 17.61%
50 66.12% 33.88% 20.08% 1.02% 12.78% 115 55.47% 44.53% 25.47% 1.39% 17.68%
51 65.95% 34.05% 20.18% 1.03% 12.85% 116 55.33% 44.68% 25.55% 1.39% 17.73%
52 65.78% 34.22% 20.25% 1.03% 12.94% 117 55.19% 44.81% 25.62% 1.39% 17.80%
53 65.62% 34.38% 20.33% 1.03% 13.02% 118 55.06% 44.94% 25.68% 1.40% 17.86%
54 65.46% 34.54% 20.41% 1.03% 13.10% 119 54.92% 45.08% 25.76% 1.41% 17.92%
55 65.29% 34.71% 20.51% 1.04% 13.17% 120 54.73% 45.27% 25.85% 1.41% 18.02%
56 65.14% 34.86% 20.59% 1.04% 13.23% 121 54.58% 45.42% 25.92% 1.41% 18.10%
57 64.98% 35.02% 20.67% 1.05% 13.31% 122 54.42% 45.58% 26.00% 1.41% 18.17%
58 64.82% 35.18% 20.74% 1.05% 13.38% 123 54.26% 45.74% 26.08% 1.42% 18.25%
59 64.65% 35.35% 20.82% 1.06% 13.47% 124 54.12% 45.89% 26.14% 1.42% 18.32%
60 64.47% 35.53% 20.92% 1.07% 13.54% 125 53.96% 46.04% 26.21% 1.43% 18.40%
61 64.31% 35.69% 21.01% 1.07% 13.62% 126 53.80% 46.20% 26.29% 1.43% 18.48%
62 64.12% 35.88% 21.10% 1.08% 13.70% 127 53.65% 46.35% 26.37% 1.44% 18.54%
63 63.94% 36.06% 21.20% 1.08% 13.78% 128 53.48% 46.52% 26.46% 1.45% 18.61%
64 63.79% 36.21% 21.27% 1.09% 13.85% 129 53.33% 46.67% 26.53% 1.45% 18.69%
65 63.63% 36.37% 21.35% 1.10% 13.93% 130 53.19% 46.81% 26.61% 1.46% 18.75%
66 63.45% 36.55% 21.45% 1.11% 14.00% 131 53.04% 46.96% 26.68% 1.46% 18.82%
67 63.29% 36.72% 21.52% 1.12% 14.08% 132 52.90% 47.10% 26.75% 1.47% 18.88%
68 63.12% 36.88% 21.61% 1.12% 14.15% 133 52.73% 47.27% 26.84% 1.47% 18.96%
69 62.96% 37.05% 21.70% 1.13% 14.22% 134 52.57% 47.43% 26.92% 1.48% 19.03%
70 62.78% 37.22% 21.80% 1.13% 14.29% 135 52.41% 47.59% 26.99% 1.49% 19.11%
71 62.62% 37.38% 21.88% 1.14% 14.36% 136 52.26% 47.74% 27.07% 1.49% 19.17%
72 62.46% 37.54% 21.96% 1.15% 14.44% 137 52.11% 47.89% 27.14% 1.50% 19.25%
73 62.31% 37.70% 22.03% 1.15% 14.51% 138 51.96% 48.04% 27.22% 1.51% 19.32%
74 62.13% 37.87% 22.13% 1.16% 14.58% 139 51.79% 48.21% 27.29% 1.51% 19.40%
75 61.99% 38.01% 22.20% 1.16% 14.65% 140 51.65% 48.35% 27.37% 1.51% 19.46%
76 61.82% 38.18% 22.29% 1.17% 14.72% 141 51.52% 48.48% 27.43% 1.52% 19.53%
77 61.65% 38.35% 22.37% 1.18% 14.81% 142 51.37% 48.63% 27.51% 1.53% 19.60%
78 61.46% 38.54% 22.46% 1.18% 14.90% 143 51.22% 48.78% 27.57% 1.53% 19.68%
79 61.31% 38.69% 22.54% 1.18% 14.97% 144 51.07% 48.93% 27.64% 1.54% 19.75%
80 61.13% 38.87% 22.62% 1.19% 15.06% 145 50.93% 49.07% 27.71% 1.54% 19.82%
81 60.98% 39.02% 22.70% 1.20% 15.13% 146 50.78% 49.22% 27.78% 1.55% 19.90%
82 60.82% 39.18% 22.78% 1.20% 15.20% 147 50.62% 49.38% 27.85% 1.56% 19.97%
83 60.65% 39.35% 22.86% 1.21% 15.28% 148 50.46% 49.54% 27.92% 1.56% 20.06%
235
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 149 50.32% 49.68% 27.99% 1.57% 20.12% 214 42.22% 57.78% 32.17% 1.83% 23.78%
150 50.17% 49.83% 28.07% 1.57% 20.19% 215 42.11% 57.89% 32.23% 1.83% 23.83%
151 50.04% 49.96% 28.14% 1.58% 20.25% 216 41.99% 58.01% 32.29% 1.84% 23.88%
152 49.90% 50.10% 28.21% 1.58% 20.31% 217 41.86% 58.14% 32.35% 1.84% 23.94%
153 49.75% 50.25% 28.30% 1.58% 20.37% 218 41.74% 58.26% 32.41% 1.85% 24.00%
154 49.60% 50.40% 28.37% 1.59% 20.44% 219 41.65% 58.35% 32.46% 1.86% 24.03%
155 49.48% 50.53% 28.44% 1.59% 20.50% 220 41.56% 58.44% 32.50% 1.86% 24.08%
156 49.32% 50.68% 28.51% 1.59% 20.58% 221 41.44% 58.56% 32.57% 1.86% 24.14%
157 49.17% 50.83% 28.59% 1.60% 20.64% 222 41.32% 58.68% 32.63% 1.87% 24.19%
158 49.01% 51.00% 28.67% 1.60% 20.72% 223 41.20% 58.80% 32.68% 1.87% 24.25%
159 48.86% 51.14% 28.74% 1.61% 20.80% 224 41.09% 58.91% 32.74% 1.88% 24.30%
160 48.72% 51.28% 28.80% 1.61% 20.87% 225 40.98% 59.02% 32.79% 1.88% 24.35%
161 48.59% 51.41% 28.86% 1.62% 20.93% 226 40.87% 59.13% 32.85% 1.89% 24.39%
162 48.45% 51.55% 28.94% 1.62% 20.99% 227 40.78% 59.22% 32.89% 1.89% 24.44%
163 48.31% 51.69% 29.00% 1.63% 21.06% 228 40.68% 59.33% 32.96% 1.89% 24.48%
164 48.17% 51.83% 29.07% 1.64% 21.13% 229 40.57% 59.43% 33.01% 1.89% 24.53%
165 48.06% 51.94% 29.13% 1.64% 21.18% 230 40.44% 59.56% 33.08% 1.90% 24.58%
166 47.91% 52.09% 29.20% 1.65% 21.24% 231 40.35% 59.65% 33.12% 1.90% 24.63%
167 47.78% 52.22% 29.26% 1.65% 21.31% 232 40.24% 59.76% 33.18% 1.91% 24.68%
168 47.66% 52.34% 29.32% 1.65% 21.37% 233 40.12% 59.88% 33.25% 1.91% 24.73%
169 47.51% 52.49% 29.40% 1.66% 21.43% 234 40.02% 59.98% 33.30% 1.91% 24.77%
170 47.39% 52.61% 29.46% 1.66% 21.49% 235 39.94% 60.07% 33.34% 1.92% 24.81%
171 47.27% 52.73% 29.52% 1.66% 21.55% 236 39.83% 60.17% 33.40% 1.92% 24.86%
172 47.16% 52.84% 29.57% 1.67% 21.60% 237 39.73% 60.27% 33.45% 1.92% 24.90%
173 47.04% 52.96% 29.64% 1.67% 21.65% 238 39.63% 60.37% 33.51% 1.92% 24.94%
174 46.90% 53.10% 29.71% 1.68% 21.72% 239 39.54% 60.46% 33.57% 1.93% 24.97%
175 46.78% 53.22% 29.77% 1.68% 21.77% 240 39.44% 60.56% 33.61% 1.93% 25.02%
176 46.64% 53.36% 29.85% 1.68% 21.83% 241 39.35% 60.65% 33.65% 1.93% 25.07%
177 46.49% 53.51% 29.93% 1.69% 21.90% 242 39.27% 60.73% 33.69% 1.93% 25.11%
178 46.37% 53.63% 29.99% 1.69% 21.95% 243 39.16% 60.84% 33.75% 1.94% 25.16%
179 46.24% 53.76% 30.06% 1.70% 22.00% 244 39.03% 60.97% 33.81% 1.95% 25.21%
180 46.11% 53.89% 30.13% 1.70% 22.05% 245 38.93% 61.07% 33.85% 1.95% 25.27%
181 45.99% 54.01% 30.19% 1.71% 22.11% 246 38.83% 61.17% 33.89% 1.96% 25.32%
182 45.88% 54.12% 30.25% 1.71% 22.16% 247 38.74% 61.27% 33.93% 1.96% 25.37%
183 45.77% 54.23% 30.30% 1.71% 22.21% 248 38.65% 61.35% 33.97% 1.97% 25.42%
184 45.66% 54.34% 30.37% 1.72% 22.26% 249 38.54% 61.46% 34.03% 1.97% 25.47%
185 45.56% 54.45% 30.42% 1.72% 22.31% 250 38.45% 61.55% 34.08% 1.97% 25.51%
186 45.43% 54.57% 30.48% 1.73% 22.36% 251 38.35% 61.65% 34.13% 1.97% 25.54%
187 45.31% 54.69% 30.54% 1.73% 22.42% 252 38.26% 61.74% 34.18% 1.98% 25.58%
188 45.21% 54.80% 30.59% 1.73% 22.47% 253 38.17% 61.83% 34.23% 1.98% 25.63%
189 45.09% 54.91% 30.65% 1.73% 22.52% 254 38.07% 61.93% 34.29% 1.98% 25.66%
190 44.97% 55.03% 30.72% 1.74% 22.57% 255 38.00% 62.00% 34.33% 1.98% 25.69%
191 44.84% 55.16% 30.79% 1.75% 22.62% 256 37.91% 62.09% 34.37% 1.99% 25.73%
192 44.71% 55.29% 30.86% 1.75% 22.68% 257 37.82% 62.18% 34.43% 1.99% 25.76%
193 44.61% 55.40% 30.90% 1.75% 22.74% 258 37.72% 62.28% 34.48% 2.00% 25.80%
194 44.48% 55.52% 30.97% 1.76% 22.79% 259 37.61% 62.39% 34.54% 2.00% 25.85%
195 44.37% 55.63% 31.02% 1.76% 22.85% 260 37.53% 62.47% 34.58% 2.00% 25.89%
196 44.25% 55.75% 31.09% 1.76% 22.90% 261 37.44% 62.57% 34.63% 2.00% 25.93%
197 44.15% 55.85% 31.14% 1.77% 22.94% 262 37.36% 62.64% 34.67% 2.00% 25.97%
198 44.03% 55.97% 31.21% 1.77% 22.99% 263 37.25% 62.75% 34.73% 2.00% 26.01%
199 43.92% 56.08% 31.27% 1.78% 23.04% 264 37.15% 62.85% 34.79% 2.01% 26.05%
200 43.80% 56.20% 31.34% 1.78% 23.09% 265 37.07% 62.93% 34.83% 2.01% 26.09%
201 43.70% 56.30% 31.39% 1.78% 23.12% 266 36.97% 63.03% 34.88% 2.02% 26.13%
202 43.58% 56.42% 31.46% 1.79% 23.17% 267 36.89% 63.11% 34.93% 2.02% 26.16%
203 43.47% 56.53% 31.52% 1.79% 23.22% 268 36.77% 63.23% 34.99% 2.02% 26.22%
204 43.36% 56.64% 31.58% 1.80% 23.27% 269 36.68% 63.32% 35.03% 2.03% 26.26%
205 43.24% 56.77% 31.64% 1.80% 23.33% 270 36.58% 63.42% 35.09% 2.03% 26.30%
206 43.12% 56.88% 31.70% 1.81% 23.38% 271 36.51% 63.49% 35.12% 2.04% 26.33%
207 43.01% 56.99% 31.75% 1.81% 23.43% 272 36.42% 63.58% 35.17% 2.04% 26.37%
208 42.89% 57.11% 31.81% 1.81% 23.48% 273 36.32% 63.68% 35.23% 2.05% 26.41%
209 42.78% 57.22% 31.88% 1.82% 23.52% 274 36.21% 63.79% 35.27% 2.05% 26.47%
210 42.66% 57.34% 31.94% 1.82% 23.58% 275 36.12% 63.88% 35.32% 2.05% 26.51%
211 42.55% 57.45% 32.00% 1.82% 23.63% 276 36.04% 63.96% 35.36% 2.06% 26.55%
212 42.44% 57.56% 32.06% 1.83% 23.68% 277 35.95% 64.05% 35.41% 2.06% 26.58%
213 42.32% 57.68% 32.11% 1.83% 23.74% 278 35.86% 64.14% 35.46% 2.06% 26.62%
236
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 279 35.78% 64.22% 35.50% 2.07% 26.65% 344 30.63% 69.37% 38.19% 2.23% 28.95%
280 35.69% 64.31% 35.55% 2.07% 26.70% 345 30.56% 69.44% 38.23% 2.24% 28.97%
281 35.61% 64.39% 35.59% 2.07% 26.73% 346 30.49% 69.51% 38.27% 2.24% 29.00%
282 35.52% 64.48% 35.64% 2.08% 26.77% 347 30.42% 69.58% 38.30% 2.24% 29.04%
283 35.45% 64.55% 35.67% 2.08% 26.81% 348 30.34% 69.66% 38.35% 2.24% 29.07%
284 35.35% 64.65% 35.71% 2.08% 26.86% 349 30.27% 69.73% 38.38% 2.25% 29.10%
285 35.26% 64.74% 35.76% 2.08% 26.89% 350 30.21% 69.80% 38.42% 2.25% 29.13%
286 35.17% 64.83% 35.81% 2.09% 26.93% 351 30.15% 69.85% 38.45% 2.25% 29.15%
287 35.09% 64.91% 35.86% 2.09% 26.97% 352 30.09% 69.91% 38.49% 2.25% 29.17%
288 35.00% 65.00% 35.91% 2.09% 27.01% 353 30.03% 69.97% 38.52% 2.26% 29.20%
289 34.89% 65.11% 35.97% 2.09% 27.06% 354 29.96% 70.05% 38.55% 2.26% 29.23%
290 34.79% 65.22% 36.02% 2.10% 27.10% 355 29.88% 70.12% 38.60% 2.26% 29.26%
291 34.72% 65.28% 36.06% 2.10% 27.12% 356 29.81% 70.19% 38.64% 2.27% 29.29%
292 34.64% 65.36% 36.10% 2.10% 27.16% 357 29.74% 70.26% 38.67% 2.27% 29.32%
293 34.55% 65.45% 36.15% 2.10% 27.20% 358 29.68% 70.32% 38.70% 2.27% 29.35%
294 34.47% 65.54% 36.18% 2.11% 27.24% 359 29.62% 70.38% 38.73% 2.27% 29.38%
295 34.38% 65.62% 36.22% 2.11% 27.28% 360 29.56% 70.44% 38.76% 2.27% 29.41%
296 34.30% 65.70% 36.26% 2.11% 27.32% 361 29.49% 70.51% 38.80% 2.28% 29.44%
297 34.23% 65.78% 36.31% 2.12% 27.35% 362 29.43% 70.57% 38.83% 2.28% 29.46%
298 34.16% 65.85% 36.35% 2.12% 27.37% 363 29.37% 70.64% 38.87% 2.28% 29.49%
299 34.06% 65.94% 36.40% 2.12% 27.42% 364 29.29% 70.71% 38.91% 2.28% 29.53%
300 33.99% 66.01% 36.43% 2.12% 27.45% 365 29.21% 70.79% 38.94% 2.28% 29.57%
301 33.92% 66.09% 36.48% 2.13% 27.49% 366 29.13% 70.87% 38.98% 2.29% 29.60%
302 33.82% 66.18% 36.52% 2.13% 27.53% 367 29.07% 70.93% 39.02% 2.29% 29.62%
303 33.73% 66.28% 36.57% 2.13% 27.57% 368 29.00% 71.00% 39.06% 2.29% 29.66%
304 33.66% 66.34% 36.61% 2.13% 27.60% 369 28.93% 71.07% 39.10% 2.29% 29.69%
305 33.58% 66.43% 36.66% 2.14% 27.63% 370 28.87% 71.13% 39.13% 2.29% 29.71%
306 33.49% 66.51% 36.70% 2.14% 27.68% 371 28.81% 71.19% 39.16% 2.29% 29.73%
307 33.41% 66.59% 36.74% 2.14% 27.71% 372 28.75% 71.25% 39.20% 2.30% 29.76%
308 33.33% 66.67% 36.78% 2.14% 27.75% 373 28.66% 71.34% 39.24% 2.30% 29.80%
309 33.25% 66.75% 36.83% 2.15% 27.78% 374 28.60% 71.40% 39.28% 2.30% 29.82%
310 33.17% 66.83% 36.86% 2.15% 27.82% 375 28.55% 71.45% 39.30% 2.30% 29.85%
311 33.09% 66.91% 36.90% 2.15% 27.86% 376 28.48% 71.52% 39.34% 2.30% 29.88%
312 33.02% 66.98% 36.93% 2.15% 27.91% 377 28.42% 71.58% 39.37% 2.30% 29.90%
313 32.94% 67.06% 36.96% 2.15% 27.95% 378 28.35% 71.65% 39.41% 2.30% 29.93%
314 32.87% 67.13% 36.99% 2.15% 27.98% 379 28.28% 71.72% 39.45% 2.30% 29.97%
315 32.79% 67.21% 37.04% 2.16% 28.02% 380 28.23% 71.77% 39.49% 2.30% 29.99%
316 32.70% 67.30% 37.09% 2.16% 28.05% 381 28.15% 71.85% 39.53% 2.31% 30.01%
317 32.63% 67.37% 37.13% 2.16% 28.07% 382 28.07% 71.93% 39.58% 2.31% 30.04%
318 32.56% 67.44% 37.17% 2.16% 28.11% 383 28.01% 71.99% 39.61% 2.31% 30.07%
319 32.49% 67.51% 37.21% 2.17% 28.14% 384 27.94% 72.06% 39.65% 2.32% 30.10%
320 32.41% 67.59% 37.26% 2.17% 28.17% 385 27.88% 72.12% 39.69% 2.32% 30.12%
321 32.33% 67.67% 37.29% 2.17% 28.20% 386 27.80% 72.20% 39.73% 2.32% 30.15%
322 32.27% 67.73% 37.33% 2.17% 28.23% 387 27.73% 72.27% 39.76% 2.33% 30.19%
323 32.19% 67.81% 37.36% 2.17% 28.27% 388 27.66% 72.34% 39.79% 2.33% 30.21%
324 32.13% 67.87% 37.40% 2.17% 28.30% 389 27.61% 72.39% 39.82% 2.33% 30.24%
325 32.04% 67.96% 37.44% 2.18% 28.34% 390 27.56% 72.44% 39.85% 2.33% 30.26%
326 31.96% 68.04% 37.49% 2.18% 28.38% 391 27.51% 72.49% 39.88% 2.34% 30.28%
327 31.88% 68.12% 37.53% 2.18% 28.41% 392 27.45% 72.55% 39.91% 2.34% 30.30%
328 31.81% 68.19% 37.57% 2.18% 28.44% 393 27.38% 72.62% 39.95% 2.34% 30.33%
329 31.73% 68.27% 37.61% 2.19% 28.47% 394 27.32% 72.68% 39.99% 2.34% 30.35%
330 31.66% 68.35% 37.65% 2.19% 28.50% 395 27.25% 72.75% 40.02% 2.35% 30.38%
331 31.58% 68.43% 37.69% 2.19% 28.54% 396 27.20% 72.81% 40.05% 2.35% 30.41%
332 31.50% 68.50% 37.74% 2.19% 28.57% 397 27.14% 72.86% 40.09% 2.35% 30.43%
333 31.44% 68.57% 37.77% 2.19% 28.60% 398 27.08% 72.92% 40.12% 2.35% 30.45%
334 31.37% 68.63% 37.81% 2.20% 28.63% 399 27.01% 73.00% 40.17% 2.36% 30.47%
335 31.30% 68.70% 37.84% 2.20% 28.66% 400 26.95% 73.05% 40.20% 2.36% 30.49%
336 31.23% 68.77% 37.88% 2.20% 28.69% 401 26.90% 73.10% 40.23% 2.36% 30.51%
337 31.16% 68.84% 37.91% 2.21% 28.72% 402 26.85% 73.15% 40.26% 2.36% 30.53%
338 31.08% 68.93% 37.96% 2.21% 28.76% 403 26.80% 73.20% 40.29% 2.37% 30.55%
339 31.00% 69.01% 37.99% 2.22% 28.80% 404 26.73% 73.27% 40.32% 2.37% 30.58%
340 30.92% 69.08% 38.03% 2.22% 28.83% 405 26.69% 73.31% 40.35% 2.37% 30.59%
341 30.85% 69.15% 38.06% 2.23% 28.86% 406 26.64% 73.37% 40.37% 2.38% 30.62%
342 30.79% 69.21% 38.10% 2.23% 28.88% 407 26.57% 73.43% 40.41% 2.38% 30.64%
343 30.71% 69.29% 38.15% 2.23% 28.92% 408 26.51% 73.49% 40.44% 2.39% 30.67%
237
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 409 26.46% 73.54% 40.47% 2.39% 30.69% 474 23.08% 76.92% 42.27% 2.51% 32.14%
410 26.40% 73.60% 40.50% 2.39% 30.72% 475 23.04% 76.97% 42.29% 2.51% 32.17%
411 26.35% 73.65% 40.52% 2.39% 30.74% 476 23.00% 77.00% 42.31% 2.51% 32.18%
412 26.29% 73.72% 40.55% 2.39% 30.77% 477 22.95% 77.05% 42.34% 2.51% 32.20%
413 26.22% 73.78% 40.59% 2.39% 30.80% 478 22.90% 77.10% 42.36% 2.52% 32.22%
414 26.15% 73.85% 40.63% 2.40% 30.82% 479 22.87% 77.14% 42.38% 2.52% 32.24%
415 26.10% 73.90% 40.66% 2.40% 30.85% 480 22.82% 77.18% 42.40% 2.52% 32.26%
416 26.05% 73.95% 40.68% 2.40% 30.88% 481 22.76% 77.24% 42.43% 2.52% 32.28%
417 26.00% 74.00% 40.71% 2.40% 30.90% 482 22.71% 77.29% 42.47% 2.53% 32.30%
418 25.94% 74.06% 40.75% 2.40% 30.91% 483 22.67% 77.34% 42.49% 2.53% 32.32%
419 25.89% 74.11% 40.77% 2.40% 30.94% 484 22.62% 77.38% 42.51% 2.53% 32.34%
420 25.83% 74.17% 40.81% 2.40% 30.96% 485 22.57% 77.43% 42.54% 2.53% 32.36%
421 25.78% 74.23% 40.85% 2.41% 30.97% 486 22.51% 77.49% 42.58% 2.53% 32.38%
422 25.72% 74.28% 40.88% 2.41% 30.99% 487 22.46% 77.54% 42.61% 2.53% 32.40%
423 25.67% 74.33% 40.90% 2.41% 31.02% 488 22.42% 77.58% 42.63% 2.53% 32.42%
424 25.61% 74.39% 40.93% 2.41% 31.05% 489 22.36% 77.64% 42.66% 2.53% 32.45%
425 25.57% 74.44% 40.95% 2.41% 31.07% 490 22.32% 77.68% 42.68% 2.53% 32.46%
426 25.52% 74.48% 40.98% 2.42% 31.08% 491 22.27% 77.73% 42.71% 2.53% 32.49%
427 25.47% 74.53% 41.01% 2.42% 31.11% 492 22.22% 77.78% 42.73% 2.53% 32.52%
428 25.41% 74.59% 41.04% 2.42% 31.13% 493 22.17% 77.83% 42.75% 2.54% 32.54%
429 25.35% 74.65% 41.06% 2.42% 31.16% 494 22.13% 77.87% 42.77% 2.54% 32.56%
430 25.29% 74.71% 41.09% 2.43% 31.19% 495 22.08% 77.92% 42.80% 2.54% 32.58%
431 25.25% 74.76% 41.12% 2.43% 31.20% 496 22.04% 77.96% 42.82% 2.54% 32.60%
432 25.18% 74.82% 41.15% 2.43% 31.24% 497 21.98% 78.02% 42.84% 2.54% 32.63%
433 25.14% 74.86% 41.17% 2.43% 31.26% 498 21.94% 78.06% 42.86% 2.54% 32.65%
434 25.10% 74.90% 41.19% 2.44% 31.27% 499 21.88% 78.12% 42.89% 2.55% 32.68%
435 25.04% 74.96% 41.22% 2.44% 31.30% 500 21.83% 78.17% 42.92% 2.55% 32.70%
436 24.99% 75.01% 41.25% 2.44% 31.32% 501 21.79% 78.21% 42.95% 2.55% 32.72%
437 24.93% 75.07% 41.28% 2.44% 31.35% 502 21.74% 78.26% 42.98% 2.55% 32.74%
438 24.88% 75.12% 41.30% 2.44% 31.37% 503 21.69% 78.31% 43.00% 2.55% 32.76%
439 24.82% 75.18% 41.34% 2.45% 31.39% 504 21.64% 78.36% 43.02% 2.55% 32.78%
440 24.77% 75.23% 41.36% 2.45% 31.42% 505 21.60% 78.40% 43.05% 2.55% 32.80%
441 24.72% 75.28% 41.39% 2.45% 31.44% 506 21.57% 78.43% 43.06% 2.55% 32.81%
442 24.66% 75.34% 41.43% 2.45% 31.46% 507 21.53% 78.47% 43.08% 2.56% 32.83%
443 24.61% 75.39% 41.45% 2.46% 31.48% 508 21.48% 78.52% 43.10% 2.56% 32.86%
444 24.56% 75.44% 41.48% 2.46% 31.50% 509 21.43% 78.57% 43.13% 2.56% 32.88%
445 24.51% 75.49% 41.51% 2.46% 31.51% 510 21.38% 78.62% 43.16% 2.56% 32.90%
446 24.46% 75.54% 41.55% 2.46% 31.53% 511 21.35% 78.66% 43.17% 2.57% 32.92%
447 24.41% 75.59% 41.57% 2.46% 31.55% 512 21.30% 78.70% 43.19% 2.57% 32.94%
448 24.38% 75.63% 41.59% 2.47% 31.57% 513 21.25% 78.75% 43.21% 2.57% 32.96%
449 24.32% 75.68% 41.62% 2.47% 31.59% 514 21.21% 78.79% 43.23% 2.57% 32.99%
450 24.27% 75.73% 41.65% 2.47% 31.61% 515 21.17% 78.83% 43.25% 2.58% 33.00%
451 24.22% 75.78% 41.68% 2.47% 31.64% 516 21.12% 78.88% 43.28% 2.58% 33.02%
452 24.17% 75.83% 41.70% 2.47% 31.65% 517 21.07% 78.93% 43.31% 2.58% 33.04%
453 24.11% 75.89% 41.73% 2.48% 31.68% 518 21.03% 78.97% 43.33% 2.58% 33.06%
454 24.07% 75.94% 41.76% 2.48% 31.70% 519 20.99% 79.01% 43.35% 2.58% 33.08%
455 24.00% 76.00% 41.79% 2.48% 31.73% 520 20.95% 79.05% 43.37% 2.58% 33.10%
456 23.96% 76.05% 41.82% 2.48% 31.75% 521 20.90% 79.10% 43.40% 2.58% 33.12%
457 23.92% 76.08% 41.84% 2.48% 31.77% 522 20.86% 79.14% 43.42% 2.58% 33.14%
458 23.89% 76.12% 41.85% 2.48% 31.78% 523 20.82% 79.18% 43.44% 2.59% 33.15%
459 23.85% 76.16% 41.88% 2.48% 31.80% 524 20.79% 79.21% 43.46% 2.59% 33.17%
460 23.78% 76.22% 41.91% 2.48% 31.83% 525 20.74% 79.26% 43.48% 2.59% 33.19%
461 23.73% 76.27% 41.94% 2.48% 31.85% 526 20.70% 79.30% 43.50% 2.59% 33.21%
462 23.68% 76.32% 41.96% 2.48% 31.88% 527 20.66% 79.34% 43.51% 2.59% 33.23%
463 23.63% 76.37% 41.99% 2.49% 31.90% 528 20.62% 79.38% 43.54% 2.59% 33.25%
464 23.57% 76.43% 42.02% 2.49% 31.92% 529 20.58% 79.42% 43.56% 2.60% 33.26%
465 23.52% 76.48% 42.06% 2.49% 31.94% 530 20.54% 79.47% 43.59% 2.60% 33.28%
466 23.47% 76.53% 42.08% 2.49% 31.96% 531 20.50% 79.50% 43.60% 2.60% 33.29%
467 23.42% 76.58% 42.10% 2.50% 31.98% 532 20.46% 79.54% 43.62% 2.61% 33.31%
468 23.36% 76.64% 42.13% 2.50% 32.01% 533 20.44% 79.57% 43.63% 2.61% 33.32%
469 23.32% 76.68% 42.15% 2.50% 32.03% 534 20.40% 79.60% 43.65% 2.61% 33.34%
470 23.28% 76.73% 42.17% 2.50% 32.05% 535 20.35% 79.65% 43.68% 2.61% 33.36%
471 23.23% 76.78% 42.20% 2.50% 32.08% 536 20.31% 79.69% 43.70% 2.61% 33.38%
472 23.16% 76.84% 42.23% 2.51% 32.10% 537 20.27% 79.73% 43.72% 2.61% 33.39%
473 23.13% 76.87% 42.25% 2.51% 32.12% 538 20.23% 79.77% 43.75% 2.61% 33.41%
238
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 539 20.20% 79.80% 43.77% 2.62% 33.42% 604 17.81% 82.19% 45.00% 2.72% 34.48%
540 20.15% 79.85% 43.80% 2.62% 33.43% 605 17.77% 82.23% 45.02% 2.72% 34.49%
541 20.11% 79.89% 43.83% 2.62% 33.45% 606 17.74% 82.27% 45.03% 2.72% 34.51%
542 20.07% 79.93% 43.85% 2.62% 33.46% 607 17.71% 82.30% 45.06% 2.72% 34.52%
543 20.04% 79.96% 43.87% 2.62% 33.47% 608 17.66% 82.34% 45.08% 2.72% 34.54%
544 20.00% 80.00% 43.89% 2.62% 33.49% 609 17.62% 82.38% 45.10% 2.72% 34.56%
545 19.96% 80.04% 43.91% 2.62% 33.51% 610 17.59% 82.41% 45.11% 2.72% 34.58%
546 19.92% 80.08% 43.94% 2.62% 33.52% 611 17.55% 82.45% 45.13% 2.72% 34.59%
547 19.88% 80.12% 43.96% 2.62% 33.54% 612 17.52% 82.48% 45.14% 2.73% 34.61%
548 19.84% 80.16% 43.98% 2.63% 33.56% 613 17.50% 82.51% 45.16% 2.73% 34.62%
549 19.80% 80.20% 44.00% 2.63% 33.58% 614 17.46% 82.54% 45.18% 2.73% 34.63%
550 19.76% 80.24% 44.01% 2.63% 33.60% 615 17.42% 82.58% 45.20% 2.73% 34.65%
551 19.72% 80.28% 44.03% 2.63% 33.62% 616 17.38% 82.63% 45.23% 2.74% 34.66%
552 19.68% 80.32% 44.04% 2.63% 33.64% 617 17.34% 82.66% 45.25% 2.74% 34.68%
553 19.64% 80.36% 44.06% 2.64% 33.66% 618 17.30% 82.70% 45.26% 2.74% 34.70%
554 19.61% 80.39% 44.07% 2.64% 33.68% 619 17.27% 82.73% 45.27% 2.75% 34.71%
555 19.57% 80.43% 44.09% 2.64% 33.69% 620 17.24% 82.76% 45.29% 2.75% 34.72%
556 19.54% 80.46% 44.11% 2.64% 33.72% 621 17.20% 82.80% 45.31% 2.75% 34.75%
557 19.50% 80.50% 44.13% 2.65% 33.73% 622 17.16% 82.84% 45.33% 2.75% 34.77%
558 19.46% 80.54% 44.14% 2.65% 33.75% 623 17.12% 82.88% 45.35% 2.75% 34.78%
559 19.43% 80.57% 44.16% 2.65% 33.76% 624 17.09% 82.91% 45.37% 2.75% 34.79%
560 19.40% 80.61% 44.18% 2.65% 33.78% 625 17.06% 82.95% 45.39% 2.75% 34.81%
561 19.35% 80.65% 44.21% 2.65% 33.79% 626 17.02% 82.98% 45.40% 2.75% 34.82%
562 19.30% 80.70% 44.23% 2.65% 33.82% 627 17.00% 83.00% 45.41% 2.75% 34.84%
563 19.26% 80.74% 44.25% 2.66% 33.83% 628 16.96% 83.04% 45.43% 2.76% 34.85%
564 19.23% 80.77% 44.27% 2.66% 33.85% 629 16.94% 83.06% 45.44% 2.76% 34.86%
565 19.19% 80.81% 44.29% 2.66% 33.86% 630 16.92% 83.09% 45.45% 2.76% 34.87%
566 19.16% 80.84% 44.30% 2.66% 33.88% 631 16.88% 83.12% 45.48% 2.76% 34.89%
567 19.12% 80.88% 44.33% 2.66% 33.89% 632 16.85% 83.16% 45.49% 2.76% 34.90%
568 19.08% 80.92% 44.35% 2.66% 33.91% 633 16.82% 83.18% 45.51% 2.76% 34.91%
569 19.04% 80.96% 44.38% 2.66% 33.93% 634 16.79% 83.21% 45.52% 2.76% 34.93%
570 19.00% 81.00% 44.39% 2.66% 33.94% 635 16.76% 83.24% 45.54% 2.77% 34.94%
571 18.97% 81.03% 44.41% 2.66% 33.95% 636 16.72% 83.28% 45.56% 2.77% 34.95%
572 18.93% 81.07% 44.43% 2.66% 33.97% 637 16.69% 83.31% 45.58% 2.77% 34.97%
573 18.89% 81.11% 44.45% 2.67% 33.99% 638 16.67% 83.33% 45.59% 2.77% 34.98%
574 18.86% 81.15% 44.47% 2.67% 34.01% 639 16.64% 83.36% 45.61% 2.77% 34.99%
575 18.82% 81.18% 44.48% 2.67% 34.03% 640 16.61% 83.39% 45.62% 2.77% 35.00%
576 18.80% 81.20% 44.49% 2.67% 34.04% 641 16.58% 83.42% 45.64% 2.77% 35.01%
577 18.76% 81.25% 44.51% 2.68% 34.06% 642 16.55% 83.45% 45.66% 2.77% 35.02%
578 18.71% 81.29% 44.54% 2.68% 34.08% 643 16.51% 83.49% 45.68% 2.78% 35.04%
579 18.68% 81.33% 44.56% 2.68% 34.09% 644 16.48% 83.52% 45.70% 2.78% 35.05%
580 18.63% 81.37% 44.58% 2.68% 34.11% 645 16.45% 83.55% 45.71% 2.78% 35.07%
581 18.60% 81.40% 44.60% 2.68% 34.12% 646 16.41% 83.59% 45.72% 2.78% 35.08%
582 18.56% 81.44% 44.62% 2.68% 34.14% 647 16.39% 83.61% 45.74% 2.78% 35.09%
583 18.53% 81.47% 44.64% 2.68% 34.15% 648 16.36% 83.64% 45.75% 2.78% 35.11%
584 18.49% 81.51% 44.65% 2.68% 34.17% 649 16.33% 83.67% 45.76% 2.79% 35.12%
585 18.46% 81.54% 44.67% 2.68% 34.19% 650 16.29% 83.71% 45.78% 2.79% 35.14%
586 18.43% 81.58% 44.69% 2.68% 34.21% 651 16.27% 83.73% 45.79% 2.79% 35.16%
587 18.40% 81.60% 44.69% 2.68% 34.22% 652 16.24% 83.76% 45.80% 2.79% 35.17%
588 18.36% 81.64% 44.71% 2.69% 34.24% 653 16.22% 83.79% 45.81% 2.79% 35.19%
589 18.32% 81.68% 44.73% 2.69% 34.26% 654 16.19% 83.81% 45.82% 2.79% 35.20%
590 18.28% 81.72% 44.75% 2.69% 34.28% 655 16.16% 83.84% 45.84% 2.79% 35.21%
591 18.25% 81.75% 44.77% 2.69% 34.29% 656 16.14% 83.86% 45.85% 2.79% 35.22%
592 18.21% 81.79% 44.79% 2.69% 34.31% 657 16.11% 83.89% 45.87% 2.79% 35.23%
593 18.18% 81.82% 44.80% 2.70% 34.32% 658 16.08% 83.92% 45.89% 2.79% 35.24%
594 18.14% 81.86% 44.82% 2.70% 34.35% 659 16.05% 83.95% 45.90% 2.80% 35.26%
595 18.10% 81.91% 44.84% 2.70% 34.37% 660 16.01% 84.00% 45.92% 2.80% 35.28%
596 18.07% 81.93% 44.86% 2.70% 34.38% 661 15.97% 84.03% 45.94% 2.80% 35.29%
597 18.03% 81.97% 44.87% 2.70% 34.39% 662 15.94% 84.06% 45.95% 2.80% 35.31%
598 18.01% 81.99% 44.88% 2.70% 34.40% 663 15.93% 84.07% 45.96% 2.80% 35.31%
599 17.98% 82.02% 44.90% 2.71% 34.41% 664 15.89% 84.11% 45.98% 2.80% 35.33%
600 17.94% 82.06% 44.93% 2.71% 34.43% 665 15.87% 84.13% 45.98% 2.80% 35.34%
601 17.91% 82.09% 44.94% 2.71% 34.44% 666 15.84% 84.16% 46.00% 2.80% 35.36%
602 17.87% 82.13% 44.97% 2.71% 34.45% 667 15.80% 84.20% 46.02% 2.80% 35.37%
603 17.84% 82.16% 44.98% 2.71% 34.46% 668 15.77% 84.23% 46.04% 2.80% 35.39%
239
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 669 15.73% 84.27% 46.06% 2.81% 35.41% 734 14.06% 85.94% 46.91% 2.88% 36.15%
670 15.70% 84.30% 46.07% 2.81% 35.42% 735 14.04% 85.96% 46.92% 2.88% 36.16%
671 15.67% 84.33% 46.08% 2.81% 35.44% 736 14.02% 85.98% 46.93% 2.88% 36.17%
672 15.64% 84.36% 46.10% 2.81% 35.45% 737 13.99% 86.01% 46.94% 2.88% 36.19%
673 15.61% 84.39% 46.12% 2.81% 35.47% 738 13.96% 86.04% 46.96% 2.88% 36.20%
674 15.58% 84.42% 46.13% 2.81% 35.48% 739 13.93% 86.07% 46.97% 2.88% 36.22%
675 15.56% 84.44% 46.14% 2.81% 35.49% 740 13.90% 86.10% 46.98% 2.88% 36.23%
676 15.53% 84.47% 46.16% 2.81% 35.50% 741 13.88% 86.13% 47.00% 2.88% 36.25%
677 15.49% 84.51% 46.18% 2.82% 35.52% 742 13.85% 86.16% 47.01% 2.88% 36.26%
678 15.47% 84.53% 46.19% 2.82% 35.53% 743 13.82% 86.18% 47.03% 2.88% 36.27%
679 15.44% 84.56% 46.20% 2.82% 35.55% 744 13.80% 86.20% 47.04% 2.89% 36.28%
680 15.42% 84.58% 46.21% 2.82% 35.56% 745 13.77% 86.23% 47.05% 2.89% 36.29%
681 15.39% 84.61% 46.22% 2.82% 35.56% 746 13.74% 86.26% 47.07% 2.89% 36.31%
682 15.37% 84.64% 46.23% 2.82% 35.58% 747 13.72% 86.28% 47.08% 2.89% 36.31%
683 15.33% 84.67% 46.25% 2.82% 35.60% 748 13.70% 86.30% 47.09% 2.89% 36.32%
684 15.31% 84.70% 46.26% 2.82% 35.61% 749 13.67% 86.33% 47.11% 2.89% 36.33%
685 15.27% 84.73% 46.28% 2.83% 35.63% 750 13.65% 86.35% 47.12% 2.89% 36.34%
686 15.24% 84.76% 46.30% 2.83% 35.64% 751 13.62% 86.38% 47.13% 2.89% 36.36%
687 15.22% 84.78% 46.31% 2.83% 35.65% 752 13.59% 86.41% 47.14% 2.90% 36.37%
688 15.19% 84.81% 46.32% 2.83% 35.66% 753 13.56% 86.44% 47.16% 2.90% 36.38%
689 15.17% 84.83% 46.33% 2.83% 35.67% 754 13.54% 86.46% 47.16% 2.90% 36.39%
690 15.15% 84.86% 46.34% 2.83% 35.68% 755 13.51% 86.49% 47.18% 2.90% 36.40%
691 15.11% 84.89% 46.36% 2.83% 35.70% 756 13.48% 86.52% 47.20% 2.91% 36.42%
692 15.08% 84.92% 46.38% 2.83% 35.71% 757 13.44% 86.56% 47.22% 2.91% 36.43%
693 15.05% 84.95% 46.39% 2.84% 35.72% 758 13.42% 86.58% 47.23% 2.91% 36.45%
694 15.03% 84.97% 46.40% 2.84% 35.73% 759 13.40% 86.60% 47.24% 2.91% 36.46%
695 15.01% 84.99% 46.42% 2.84% 35.74% 760 13.37% 86.63% 47.26% 2.91% 36.47%
696 14.99% 85.01% 46.43% 2.84% 35.75% 761 13.35% 86.65% 47.27% 2.91% 36.48%
697 14.96% 85.04% 46.45% 2.84% 35.75% 762 13.32% 86.68% 47.28% 2.91% 36.49%
698 14.95% 85.05% 46.45% 2.84% 35.76% 763 13.29% 86.71% 47.29% 2.91% 36.50%
699 14.91% 85.09% 46.48% 2.84% 35.77% 764 13.28% 86.72% 47.30% 2.91% 36.52%
700 14.89% 85.11% 46.49% 2.84% 35.78% 765 13.26% 86.75% 47.30% 2.91% 36.53%
701 14.86% 85.14% 46.50% 2.85% 35.79% 766 13.22% 86.78% 47.32% 2.92% 36.54%
702 14.83% 85.17% 46.52% 2.85% 35.80% 767 13.20% 86.80% 47.33% 2.92% 36.55%
703 14.82% 85.19% 46.53% 2.85% 35.81% 768 13.18% 86.82% 47.34% 2.92% 36.56%
704 14.80% 85.20% 46.53% 2.85% 35.82% 769 13.15% 86.85% 47.36% 2.92% 36.57%
705 14.78% 85.22% 46.55% 2.85% 35.83% 770 13.13% 86.87% 47.37% 2.92% 36.58%
706 14.75% 85.25% 46.56% 2.85% 35.85% 771 13.10% 86.90% 47.39% 2.92% 36.59%
707 14.73% 85.28% 46.57% 2.85% 35.85% 772 13.08% 86.92% 47.40% 2.92% 36.60%
708 14.71% 85.30% 46.58% 2.85% 35.87% 773 13.06% 86.94% 47.41% 2.92% 36.61%
709 14.68% 85.32% 46.59% 2.86% 35.88% 774 13.03% 86.97% 47.42% 2.92% 36.62%
710 14.66% 85.34% 46.60% 2.86% 35.89% 775 13.01% 86.99% 47.43% 2.92% 36.64%
711 14.63% 85.37% 46.61% 2.86% 35.90% 776 12.99% 87.02% 47.45% 2.92% 36.65%
712 14.60% 85.40% 46.63% 2.86% 35.91% 777 12.97% 87.03% 47.46% 2.92% 36.65%
713 14.58% 85.42% 46.64% 2.86% 35.92% 778 12.94% 87.06% 47.47% 2.93% 36.67%
714 14.55% 85.45% 46.66% 2.86% 35.93% 779 12.92% 87.08% 47.47% 2.93% 36.68%
715 14.52% 85.48% 46.67% 2.86% 35.94% 780 12.90% 87.10% 47.49% 2.93% 36.68%
716 14.50% 85.50% 46.68% 2.86% 35.95% 781 12.88% 87.12% 47.49% 2.93% 36.69%
717 14.48% 85.52% 46.70% 2.87% 35.96% 782 12.87% 87.13% 47.50% 2.93% 36.70%
718 14.46% 85.54% 46.70% 2.87% 35.97% 783 12.85% 87.15% 47.51% 2.93% 36.71%
719 14.43% 85.57% 46.72% 2.87% 35.99% 784 12.82% 87.18% 47.53% 2.93% 36.71%
720 14.40% 85.60% 46.74% 2.87% 36.00% 785 12.80% 87.20% 47.55% 2.93% 36.72%
721 14.37% 85.63% 46.75% 2.87% 36.01% 786 12.78% 87.22% 47.56% 2.93% 36.73%
722 14.35% 85.65% 46.77% 2.87% 36.02% 787 12.75% 87.25% 47.57% 2.94% 36.75%
723 14.33% 85.67% 46.78% 2.87% 36.03% 788 12.73% 87.27% 47.58% 2.94% 36.76%
724 14.30% 85.70% 46.79% 2.87% 36.04% 789 12.71% 87.29% 47.59% 2.94% 36.77%
725 14.27% 85.73% 46.81% 2.87% 36.06% 790 12.68% 87.32% 47.60% 2.94% 36.78%
726 14.24% 85.76% 46.82% 2.87% 36.07% 791 12.66% 87.34% 47.61% 2.94% 36.79%
727 14.22% 85.78% 46.83% 2.87% 36.08% 792 12.64% 87.36% 47.62% 2.94% 36.80%
728 14.20% 85.80% 46.84% 2.87% 36.08% 793 12.62% 87.38% 47.63% 2.94% 36.81%
729 14.18% 85.82% 46.86% 2.87% 36.09% 794 12.60% 87.40% 47.64% 2.94% 36.82%
730 14.16% 85.85% 46.87% 2.88% 36.10% 795 12.57% 87.43% 47.65% 2.95% 36.83%
731 14.13% 85.87% 46.88% 2.88% 36.11% 796 12.55% 87.45% 47.67% 2.95% 36.84%
732 14.11% 85.89% 46.89% 2.88% 36.13% 797 12.53% 87.47% 47.67% 2.95% 36.85%
733 14.09% 85.91% 46.90% 2.88% 36.14% 798 12.52% 87.48% 47.68% 2.95% 36.86%
240
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 799 12.50% 87.50% 47.69% 2.95% 36.87% 864 11.17% 88.83% 48.33% 3.00% 37.50%
800 12.48% 87.52% 47.69% 2.95% 36.88% 865 11.16% 88.85% 48.34% 3.00% 37.50%
801 12.46% 87.54% 47.70% 2.95% 36.89% 866 11.14% 88.86% 48.35% 3.00% 37.51%
802 12.45% 87.55% 47.71% 2.95% 36.89% 867 11.11% 88.89% 48.36% 3.01% 37.52%
803 12.42% 87.58% 47.72% 2.95% 36.91% 868 11.10% 88.91% 48.37% 3.01% 37.53%
804 12.39% 87.61% 47.73% 2.96% 36.92% 869 11.08% 88.92% 48.38% 3.01% 37.53%
805 12.38% 87.63% 47.74% 2.96% 36.93% 870 11.06% 88.94% 48.40% 3.01% 37.54%
806 12.35% 87.66% 47.76% 2.96% 36.94% 871 11.04% 88.96% 48.41% 3.01% 37.55%
807 12.32% 87.68% 47.78% 2.96% 36.95% 872 11.02% 88.99% 48.42% 3.01% 37.56%
808 12.29% 87.71% 47.79% 2.96% 36.97% 873 10.99% 89.01% 48.43% 3.01% 37.57%
809 12.26% 87.74% 47.80% 2.96% 36.98% 874 10.97% 89.03% 48.44% 3.01% 37.59%
810 12.24% 87.76% 47.82% 2.96% 36.99% 875 10.95% 89.05% 48.45% 3.01% 37.60%
811 12.21% 87.79% 47.83% 2.96% 37.00% 876 10.93% 89.07% 48.46% 3.01% 37.61%
812 12.19% 87.81% 47.85% 2.96% 37.01% 877 10.91% 89.09% 48.46% 3.01% 37.62%
813 12.16% 87.84% 47.85% 2.96% 37.03% 878 10.90% 89.11% 48.47% 3.01% 37.62%
814 12.15% 87.85% 47.86% 2.96% 37.03% 879 10.88% 89.12% 48.48% 3.01% 37.63%
815 12.12% 87.88% 47.87% 2.96% 37.04% 880 10.86% 89.14% 48.49% 3.01% 37.64%
816 12.11% 87.89% 47.88% 2.96% 37.05% 881 10.84% 89.16% 48.49% 3.01% 37.65%
817 12.09% 87.91% 47.89% 2.97% 37.06% 882 10.82% 89.18% 48.50% 3.01% 37.66%
818 12.07% 87.93% 47.90% 2.97% 37.07% 883 10.81% 89.19% 48.51% 3.01% 37.67%
819 12.05% 87.95% 47.91% 2.97% 37.08% 884 10.78% 89.22% 48.52% 3.01% 37.68%
820 12.03% 87.97% 47.91% 2.97% 37.09% 885 10.76% 89.24% 48.53% 3.01% 37.69%
821 12.02% 87.98% 47.92% 2.97% 37.10% 886 10.76% 89.25% 48.54% 3.02% 37.69%
822 12.00% 88.01% 47.93% 2.97% 37.11% 887 10.74% 89.27% 48.55% 3.02% 37.70%
823 11.98% 88.02% 47.94% 2.97% 37.11% 888 10.72% 89.28% 48.55% 3.02% 37.71%
824 11.96% 88.04% 47.95% 2.97% 37.12% 889 10.70% 89.30% 48.57% 3.02% 37.72%
825 11.93% 88.07% 47.96% 2.97% 37.14% 890 10.69% 89.31% 48.57% 3.02% 37.72%
826 11.91% 88.09% 47.97% 2.97% 37.15% 891 10.67% 89.33% 48.58% 3.02% 37.73%
827 11.88% 88.12% 47.98% 2.97% 37.16% 892 10.66% 89.34% 48.59% 3.02% 37.73%
828 11.86% 88.14% 47.99% 2.97% 37.17% 893 10.64% 89.36% 48.60% 3.02% 37.74%
829 11.85% 88.15% 48.00% 2.97% 37.18% 894 10.63% 89.37% 48.61% 3.02% 37.75%
830 11.83% 88.17% 48.01% 2.97% 37.19% 895 10.62% 89.38% 48.61% 3.02% 37.75%
831 11.80% 88.20% 48.03% 2.97% 37.20% 896 10.61% 89.40% 48.62% 3.02% 37.76%
832 11.79% 88.21% 48.03% 2.97% 37.20% 897 10.59% 89.41% 48.63% 3.02% 37.76%
833 11.77% 88.23% 48.04% 2.98% 37.21% 898 10.58% 89.42% 48.63% 3.02% 37.77%
834 11.75% 88.25% 48.05% 2.98% 37.22% 899 10.56% 89.44% 48.64% 3.03% 37.78%
835 11.73% 88.27% 48.07% 2.98% 37.23% 900 10.53% 89.47% 48.65% 3.03% 37.79%
836 11.70% 88.30% 48.08% 2.98% 37.24% 901 10.51% 89.49% 48.66% 3.03% 37.80%
837 11.68% 88.32% 48.09% 2.98% 37.25% 902 10.49% 89.51% 48.67% 3.03% 37.81%
838 11.66% 88.34% 48.10% 2.98% 37.26% 903 10.47% 89.53% 48.68% 3.03% 37.82%
839 11.64% 88.36% 48.11% 2.98% 37.27% 904 10.46% 89.54% 48.69% 3.03% 37.83%
840 11.62% 88.38% 48.12% 2.98% 37.28% 905 10.44% 89.56% 48.69% 3.03% 37.84%
841 11.59% 88.41% 48.14% 2.98% 37.29% 906 10.42% 89.58% 48.70% 3.03% 37.85%
842 11.58% 88.42% 48.14% 2.98% 37.30% 907 10.40% 89.60% 48.71% 3.03% 37.86%
843 11.56% 88.44% 48.15% 2.98% 37.31% 908 10.38% 89.62% 48.72% 3.03% 37.87%
844 11.54% 88.47% 48.16% 2.98% 37.32% 909 10.36% 89.64% 48.73% 3.03% 37.87%
845 11.52% 88.48% 48.17% 2.98% 37.33% 910 10.34% 89.66% 48.74% 3.03% 37.88%
846 11.50% 88.51% 48.18% 2.99% 37.34% 911 10.33% 89.67% 48.75% 3.03% 37.89%
847 11.48% 88.52% 48.19% 2.99% 37.35% 912 10.32% 89.68% 48.76% 3.03% 37.89%
848 11.46% 88.54% 48.20% 2.99% 37.36% 913 10.30% 89.70% 48.76% 3.04% 37.90%
849 11.44% 88.56% 48.20% 2.99% 37.36% 914 10.29% 89.72% 48.77% 3.04% 37.91%
850 11.43% 88.57% 48.21% 2.99% 37.37% 915 10.27% 89.73% 48.77% 3.04% 37.92%
851 11.41% 88.59% 48.22% 2.99% 37.38% 916 10.26% 89.75% 48.78% 3.04% 37.92%
852 11.39% 88.61% 48.23% 2.99% 37.39% 917 10.24% 89.76% 48.79% 3.04% 37.93%
853 11.38% 88.62% 48.23% 2.99% 37.39% 918 10.22% 89.78% 48.80% 3.04% 37.94%
854 11.37% 88.63% 48.24% 2.99% 37.40% 919 10.21% 89.79% 48.81% 3.04% 37.95%
855 11.35% 88.65% 48.25% 3.00% 37.41% 920 10.20% 89.81% 48.81% 3.04% 37.95%
856 11.33% 88.67% 48.26% 3.00% 37.41% 921 10.19% 89.82% 48.82% 3.04% 37.96%
857 11.32% 88.69% 48.26% 3.00% 37.43% 922 10.17% 89.84% 48.83% 3.04% 37.96%
858 11.29% 88.71% 48.27% 3.00% 37.44% 923 10.15% 89.85% 48.84% 3.04% 37.97%
859 11.28% 88.72% 48.28% 3.00% 37.45% 924 10.13% 89.87% 48.85% 3.05% 37.98%
860 11.26% 88.75% 48.29% 3.00% 37.46% 925 10.11% 89.89% 48.85% 3.05% 37.99%
861 11.24% 88.76% 48.30% 3.00% 37.46% 926 10.09% 89.91% 48.87% 3.05% 38.00%
862 11.21% 88.79% 48.31% 3.00% 37.48% 927 10.08% 89.92% 48.87% 3.05% 38.01%
863 11.19% 88.81% 48.32% 3.00% 37.49% 928 10.07% 89.93% 48.87% 3.05% 38.02%
241
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 929 10.05% 89.95% 48.88% 3.05% 38.03% 994 9.06% 90.94% 49.31% 3.09% 38.54%
930 10.04% 89.96% 48.88% 3.05% 38.03% 995 9.05% 90.95% 49.32% 3.09% 38.55%
931 10.03% 89.97% 48.89% 3.05% 38.04% 996 9.03% 90.97% 49.33% 3.09% 38.56%
932 10.01% 89.99% 48.89% 3.05% 38.05% 997 9.01% 90.99% 49.33% 3.09% 38.56%
933 9.99% 90.01% 48.90% 3.05% 38.06% 998 9.00% 91.00% 49.34% 3.09% 38.57%
934 9.97% 90.03% 48.90% 3.05% 38.07% 999 8.99% 91.02% 49.34% 3.09% 38.58%
935 9.95% 90.05% 48.91% 3.06% 38.08% 1000 8.96% 91.04% 49.36% 3.09% 38.59%
936 9.94% 90.06% 48.91% 3.06% 38.09% 1001 8.95% 91.05% 49.36% 3.09% 38.60%
937 9.93% 90.08% 48.92% 3.06% 38.10% 1002 8.94% 91.06% 49.37% 3.09% 38.60%
938 9.91% 90.09% 48.93% 3.06% 38.11% 1003 8.93% 91.07% 49.37% 3.09% 38.61%
939 9.90% 90.10% 48.93% 3.06% 38.11% 1004 8.92% 91.08% 49.37% 3.10% 38.62%
940 9.88% 90.12% 48.94% 3.06% 38.13% 1005 8.90% 91.10% 49.38% 3.10% 38.62%
941 9.86% 90.14% 48.95% 3.06% 38.13% 1006 8.89% 91.11% 49.38% 3.10% 38.63%
942 9.84% 90.16% 48.95% 3.06% 38.15% 1007 8.87% 91.13% 49.39% 3.10% 38.64%
943 9.83% 90.18% 48.96% 3.06% 38.16% 1008 8.86% 91.14% 49.40% 3.10% 38.65%
944 9.80% 90.20% 48.97% 3.06% 38.17% 1009 8.84% 91.16% 49.41% 3.10% 38.65%
945 9.79% 90.21% 48.98% 3.06% 38.17% 1010 8.84% 91.16% 49.41% 3.10% 38.66%
946 9.77% 90.23% 49.00% 3.06% 38.18% 1011 8.82% 91.18% 49.42% 3.10% 38.66%
947 9.75% 90.25% 49.01% 3.06% 38.19% 1012 8.81% 91.19% 49.42% 3.10% 38.67%
948 9.74% 90.27% 49.02% 3.06% 38.19% 1013 8.80% 91.20% 49.43% 3.10% 38.67%
949 9.72% 90.28% 49.02% 3.06% 38.20% 1014 8.79% 91.21% 49.44% 3.10% 38.68%
950 9.70% 90.31% 49.03% 3.06% 38.21% 1015 8.77% 91.23% 49.44% 3.10% 38.69%
951 9.68% 90.32% 49.04% 3.06% 38.22% 1016 8.76% 91.24% 49.45% 3.10% 38.69%
952 9.67% 90.33% 49.05% 3.06% 38.22% 1017 8.74% 91.26% 49.46% 3.10% 38.70%
953 9.65% 90.35% 49.06% 3.06% 38.23% 1018 8.73% 91.27% 49.47% 3.10% 38.71%
954 9.63% 90.37% 49.06% 3.06% 38.24% 1019 8.72% 91.28% 49.47% 3.10% 38.71%
955 9.62% 90.38% 49.07% 3.06% 38.25% 1020 8.71% 91.29% 49.47% 3.10% 38.72%
956 9.61% 90.40% 49.08% 3.06% 38.25% 1021 8.70% 91.30% 49.48% 3.10% 38.73%
957 9.59% 90.41% 49.09% 3.06% 38.26% 1022 8.69% 91.31% 49.48% 3.10% 38.73%
958 9.57% 90.43% 49.09% 3.07% 38.27% 1023 8.68% 91.32% 49.49% 3.10% 38.74%
959 9.56% 90.44% 49.10% 3.07% 38.28% 1024 8.66% 91.34% 49.50% 3.10% 38.75%
960 9.55% 90.45% 49.10% 3.07% 38.28% 1025 8.64% 91.36% 49.50% 3.11% 38.75%
961 9.53% 90.47% 49.11% 3.07% 38.29% 1026 8.63% 91.37% 49.50% 3.11% 38.76%
962 9.52% 90.48% 49.11% 3.07% 38.30% 1027 8.62% 91.38% 49.51% 3.11% 38.77%
963 9.50% 90.50% 49.12% 3.07% 38.32% 1028 8.61% 91.39% 49.51% 3.11% 38.77%
964 9.48% 90.52% 49.13% 3.07% 38.32% 1029 8.60% 91.40% 49.52% 3.11% 38.78%
965 9.47% 90.53% 49.13% 3.07% 38.33% 1030 8.59% 91.41% 49.52% 3.11% 38.79%
966 9.46% 90.54% 49.14% 3.07% 38.34% 1031 8.58% 91.43% 49.53% 3.11% 38.79%
967 9.44% 90.56% 49.15% 3.07% 38.34% 1032 8.56% 91.44% 49.54% 3.11% 38.80%
968 9.42% 90.58% 49.15% 3.07% 38.35% 1033 8.55% 91.45% 49.54% 3.11% 38.81%
969 9.42% 90.58% 49.16% 3.08% 38.35% 1034 8.54% 91.46% 49.54% 3.11% 38.81%
970 9.40% 90.60% 49.16% 3.08% 38.36% 1035 8.53% 91.47% 49.55% 3.11% 38.82%
971 9.39% 90.61% 49.17% 3.08% 38.37% 1036 8.51% 91.49% 49.56% 3.11% 38.83%
972 9.38% 90.62% 49.17% 3.08% 38.37% 1037 8.49% 91.51% 49.56% 3.11% 38.83%
973 9.37% 90.63% 49.17% 3.08% 38.38% 1038 8.49% 91.51% 49.56% 3.11% 38.83%
974 9.35% 90.65% 49.19% 3.08% 38.39% 1039 8.47% 91.53% 49.58% 3.11% 38.84%
975 9.33% 90.67% 49.19% 3.08% 38.40% 1040 8.47% 91.53% 49.58% 3.11% 38.84%
976 9.32% 90.68% 49.20% 3.08% 38.41% 1041 8.45% 91.55% 49.58% 3.11% 38.85%
977 9.30% 90.70% 49.20% 3.08% 38.42% 1042 8.44% 91.56% 49.59% 3.11% 38.86%
978 9.29% 90.71% 49.21% 3.08% 38.43% 1043 8.43% 91.57% 49.59% 3.12% 38.86%
979 9.28% 90.73% 49.22% 3.08% 38.43% 1044 8.42% 91.58% 49.60% 3.12% 38.87%
980 9.26% 90.74% 49.22% 3.08% 38.44% 1045 8.42% 91.58% 49.60% 3.12% 38.87%
981 9.25% 90.75% 49.23% 3.08% 38.45% 1046 8.41% 91.59% 49.60% 3.12% 38.87%
982 9.23% 90.77% 49.23% 3.08% 38.46% 1047 8.40% 91.60% 49.61% 3.12% 38.88%
983 9.21% 90.79% 49.24% 3.08% 38.47% 1048 8.39% 91.61% 49.62% 3.12% 38.88%
984 9.20% 90.80% 49.25% 3.08% 38.47% 1049 8.38% 91.62% 49.62% 3.12% 38.89%
985 9.18% 90.82% 49.26% 3.08% 38.48% 1050 8.36% 91.64% 49.63% 3.12% 38.89%
986 9.17% 90.83% 49.26% 3.08% 38.49% 1051 8.36% 91.64% 49.63% 3.12% 38.90%
987 9.15% 90.85% 49.27% 3.08% 38.50% 1052 8.33% 91.67% 49.63% 3.12% 38.92%
988 9.13% 90.87% 49.28% 3.08% 38.51% 1053 8.32% 91.68% 49.64% 3.12% 38.93%
989 9.12% 90.88% 49.28% 3.08% 38.52% 1054 8.31% 91.70% 49.65% 3.12% 38.93%
990 9.11% 90.89% 49.29% 3.08% 38.52% 1055 8.30% 91.70% 49.65% 3.12% 38.94%
991 9.10% 90.90% 49.29% 3.08% 38.53% 1056 8.28% 91.72% 49.66% 3.12% 38.94%
992 9.09% 90.91% 49.30% 3.08% 38.53% 1057 8.27% 91.73% 49.66% 3.12% 38.95%
993 9.08% 90.93% 49.30% 3.08% 38.54% 1058 8.27% 91.73% 49.67% 3.12% 38.95%
242
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 1059 8.25% 91.75% 49.68% 3.12% 38.96% 1124 7.52% 92.48% 50.00% 3.15% 39.33%
1060 8.24% 91.76% 49.68% 3.12% 38.96% 1125 7.50% 92.50% 50.01% 3.16% 39.33%
1061 8.23% 91.77% 49.68% 3.12% 38.97% 1126 7.49% 92.51% 50.02% 3.16% 39.34%
1062 8.22% 91.78% 49.69% 3.12% 38.97% 1127 7.48% 92.52% 50.03% 3.16% 39.34%
1063 8.21% 91.79% 49.69% 3.12% 38.98% 1128 7.47% 92.54% 50.03% 3.16% 39.35%
1064 8.20% 91.80% 49.69% 3.12% 38.99% 1129 7.45% 92.55% 50.05% 3.16% 39.35%
1065 8.19% 91.81% 49.70% 3.12% 38.99% 1130 7.44% 92.56% 50.05% 3.16% 39.36%
1066 8.18% 91.82% 49.70% 3.12% 39.00% 1131 7.43% 92.57% 50.05% 3.16% 39.36%
1067 8.17% 91.83% 49.71% 3.12% 39.00% 1132 7.42% 92.58% 50.06% 3.16% 39.37%
1068 8.16% 91.84% 49.71% 3.12% 39.01% 1133 7.41% 92.59% 50.07% 3.16% 39.37%
1069 8.16% 91.85% 49.71% 3.12% 39.01% 1134 7.39% 92.61% 50.07% 3.16% 39.38%
1070 8.15% 91.85% 49.71% 3.12% 39.02% 1135 7.38% 92.62% 50.08% 3.16% 39.38%
1071 8.13% 91.87% 49.72% 3.12% 39.02% 1136 7.37% 92.63% 50.08% 3.16% 39.39%
1072 8.11% 91.89% 49.73% 3.12% 39.03% 1137 7.36% 92.64% 50.09% 3.16% 39.40%
1073 8.10% 91.90% 49.74% 3.12% 39.04% 1138 7.35% 92.65% 50.09% 3.16% 39.40%
1074 8.09% 91.91% 49.74% 3.13% 39.05% 1139 7.34% 92.66% 50.10% 3.16% 39.41%
1075 8.08% 91.92% 49.75% 3.13% 39.05% 1140 7.33% 92.67% 50.10% 3.16% 39.41%
1076 8.07% 91.93% 49.75% 3.13% 39.06% 1141 7.31% 92.69% 50.11% 3.16% 39.42%
1077 8.05% 91.95% 49.76% 3.13% 39.06% 1142 7.31% 92.69% 50.11% 3.16% 39.42%
1078 8.04% 91.96% 49.77% 3.13% 39.06% 1143 7.30% 92.70% 50.12% 3.16% 39.43%
1079 8.04% 91.96% 49.77% 3.13% 39.06% 1144 7.29% 92.71% 50.12% 3.16% 39.44%
1080 8.03% 91.97% 49.78% 3.13% 39.07% 1145 7.28% 92.72% 50.12% 3.16% 39.44%
1081 8.02% 91.98% 49.78% 3.13% 39.07% 1146 7.27% 92.74% 50.13% 3.16% 39.45%
1082 8.00% 92.00% 49.79% 3.13% 39.09% 1147 7.25% 92.75% 50.13% 3.16% 39.46%
1083 7.99% 92.01% 49.79% 3.13% 39.09% 1148 7.24% 92.76% 50.14% 3.16% 39.46%
1084 7.98% 92.03% 49.80% 3.13% 39.10% 1149 7.23% 92.77% 50.14% 3.16% 39.47%
1085 7.96% 92.04% 49.80% 3.13% 39.10% 1150 7.22% 92.79% 50.15% 3.16% 39.47%
1086 7.96% 92.04% 49.80% 3.13% 39.11% 1151 7.21% 92.79% 50.16% 3.16% 39.48%
1087 7.95% 92.05% 49.81% 3.13% 39.12% 1152 7.20% 92.80% 50.16% 3.16% 39.48%
1088 7.94% 92.06% 49.81% 3.13% 39.12% 1153 7.19% 92.81% 50.16% 3.16% 39.49%
1089 7.93% 92.07% 49.82% 3.13% 39.12% 1154 7.18% 92.83% 50.17% 3.16% 39.49%
1090 7.91% 92.09% 49.83% 3.13% 39.13% 1155 7.16% 92.84% 50.18% 3.16% 39.50%
1091 7.90% 92.10% 49.83% 3.13% 39.14% 1156 7.14% 92.86% 50.19% 3.17% 39.51%
1092 7.89% 92.11% 49.83% 3.13% 39.14% 1157 7.13% 92.87% 50.19% 3.17% 39.51%
1093 7.88% 92.12% 49.84% 3.14% 39.15% 1158 7.13% 92.87% 50.19% 3.17% 39.52%
1094 7.87% 92.13% 49.85% 3.14% 39.15% 1159 7.12% 92.88% 50.19% 3.17% 39.52%
1095 7.86% 92.14% 49.85% 3.14% 39.16% 1160 7.11% 92.89% 50.19% 3.17% 39.53%
1096 7.84% 92.16% 49.85% 3.14% 39.17% 1161 7.10% 92.90% 50.20% 3.17% 39.53%
1097 7.83% 92.17% 49.86% 3.14% 39.17% 1162 7.09% 92.91% 50.20% 3.17% 39.54%
1098 7.82% 92.18% 49.87% 3.14% 39.18% 1163 7.08% 92.92% 50.20% 3.17% 39.54%
1099 7.81% 92.19% 49.87% 3.14% 39.18% 1164 7.08% 92.93% 50.21% 3.17% 39.55%
1100 7.80% 92.20% 49.88% 3.14% 39.18% 1165 7.07% 92.93% 50.22% 3.17% 39.55%
1101 7.79% 92.21% 49.88% 3.14% 39.19% 1166 7.06% 92.94% 50.22% 3.17% 39.56%
1102 7.78% 92.22% 49.89% 3.14% 39.19% 1167 7.04% 92.96% 50.23% 3.17% 39.56%
1103 7.77% 92.23% 49.89% 3.14% 39.20% 1168 7.03% 92.97% 50.23% 3.17% 39.57%
1104 7.76% 92.24% 49.90% 3.14% 39.21% 1169 7.02% 92.99% 50.24% 3.17% 39.57%
1105 7.75% 92.26% 49.90% 3.14% 39.21% 1170 7.01% 92.99% 50.24% 3.17% 39.58%
1106 7.72% 92.28% 49.91% 3.14% 39.23% 1171 7.00% 93.00% 50.25% 3.18% 39.58%
1107 7.71% 92.29% 49.91% 3.14% 39.23% 1172 6.98% 93.02% 50.25% 3.18% 39.59%
1108 7.70% 92.30% 49.92% 3.14% 39.24% 1173 6.98% 93.03% 50.26% 3.18% 39.59%
1109 7.69% 92.31% 49.93% 3.14% 39.24% 1174 6.97% 93.03% 50.26% 3.18% 39.60%
1110 7.68% 92.32% 49.93% 3.14% 39.24% 1175 6.96% 93.04% 50.27% 3.18% 39.60%
1111 7.67% 92.33% 49.94% 3.15% 39.25% 1176 6.95% 93.05% 50.27% 3.18% 39.60%
1112 7.65% 92.35% 49.94% 3.15% 39.26% 1177 6.95% 93.05% 50.27% 3.18% 39.61%
1113 7.64% 92.36% 49.95% 3.15% 39.27% 1178 6.94% 93.06% 50.28% 3.18% 39.61%
1114 7.63% 92.38% 49.96% 3.15% 39.27% 1179 6.93% 93.07% 50.28% 3.18% 39.61%
1115 7.62% 92.38% 49.96% 3.15% 39.27% 1180 6.92% 93.08% 50.28% 3.18% 39.62%
1116 7.61% 92.39% 49.96% 3.15% 39.28% 1181 6.91% 93.09% 50.29% 3.18% 39.62%
1117 7.61% 92.39% 49.97% 3.15% 39.28% 1182 6.90% 93.10% 50.29% 3.18% 39.63%
1118 7.59% 92.41% 49.97% 3.15% 39.29% 1183 6.90% 93.11% 50.30% 3.18% 39.63%
1119 7.58% 92.42% 49.98% 3.15% 39.29% 1184 6.88% 93.12% 50.30% 3.18% 39.63%
1120 7.56% 92.44% 49.98% 3.15% 39.30% 1185 6.87% 93.13% 50.31% 3.18% 39.64%
1121 7.55% 92.45% 49.99% 3.15% 39.31% 1186 6.85% 93.15% 50.32% 3.18% 39.65%
1122 7.54% 92.46% 50.00% 3.15% 39.32% 1187 6.84% 93.16% 50.32% 3.18% 39.66%
1123 7.53% 92.47% 50.00% 3.15% 39.32% 1188 6.83% 93.17% 50.33% 3.18% 39.66%
243
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 1189 6.82% 93.18% 50.33% 3.18% 39.67%
1190 6.81% 93.19% 50.34% 3.18% 39.67%
1191 6.81% 93.19% 50.34% 3.18% 39.67%
1192 6.79% 93.21% 50.34% 3.18% 39.68%
1193 6.79% 93.21% 50.34% 3.18% 39.69%
1194 6.78% 93.22% 50.35% 3.18% 39.69%
1195 6.76% 93.24% 50.35% 3.18% 39.70%
1196 6.76% 93.25% 50.36% 3.18% 39.71%
1197 6.75% 93.26% 50.36% 3.18% 39.71%
1198 6.73% 93.27% 50.36% 3.19% 39.72%
1199 6.71% 93.29% 50.37% 3.19% 39.73%
1200 6.70% 93.30% 50.37% 3.19% 39.74%
244
-306 98.79% 1.21% 0.33% 0.88% 0.00%
-305 98.79% 1.21% 0.33% 0.88% 0.00%
-304 98.77% 1.23% 0.34% 0.89% 0.00%
Table B9. LOCA Probability History for ASP-08 -303 98.76% 1.24% 0.34% 0.89% 0.00%
for Days After TOD -302 98.75% 1.25% 0.35% 0.90% 0.00%
-301 98.74% 1.26% 0.36% 0.91% 0.00%
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA -300 98.73% 1.27% 0.36% 0.91% 0.00%
-365 99.27% 0.73% 0.15% 0.58% 0.00% -299 98.71% 1.29% 0.37% 0.92% 0.00%
-364 99.26% 0.74% 0.15% 0.59% 0.00% -298 98.70% 1.30% 0.37% 0.93% 0.00%
-363 99.26% 0.74% 0.16% 0.59% 0.00% -297 98.69% 1.31% 0.38% 0.93% 0.00%
-362 99.25% 0.75% 0.16% 0.60% 0.00% -296 98.69% 1.31% 0.38% 0.94% 0.00%
-361 99.24% 0.76% 0.16% 0.60% 0.00% -295 98.68% 1.33% 0.39% 0.94% 0.00%
-360 99.24% 0.76% 0.16% 0.60% 0.00% -294 98.67% 1.34% 0.39% 0.95% 0.00%
-359 99.23% 0.77% 0.16% 0.61% 0.00% -293 98.65% 1.35% 0.40% 0.95% 0.00%
-358 99.22% 0.78% 0.16% 0.61% 0.00% -292 98.64% 1.36% 0.41% 0.96% 0.00%
-357 99.22% 0.79% 0.17% 0.62% 0.00% -291 98.62% 1.38% 0.42% 0.96% 0.00%
-356 99.21% 0.79% 0.17% 0.62% 0.00% -290 98.60% 1.40% 0.43% 0.97% 0.00%
-355 99.20% 0.80% 0.17% 0.62% 0.00% -289 98.59% 1.41% 0.44% 0.98% 0.00%
-354 99.20% 0.80% 0.18% 0.63% 0.00% -288 98.57% 1.43% 0.45% 0.99% 0.00%
-353 99.19% 0.81% 0.18% 0.63% 0.00% -287 98.56% 1.45% 0.45% 0.99% 0.00%
-352 99.19% 0.82% 0.18% 0.63% 0.00% -286 98.54% 1.46% 0.46% 1.00% 0.00%
-351 99.18% 0.82% 0.18% 0.63% 0.00% -285 98.53% 1.47% 0.46% 1.01% 0.00%
-350 99.17% 0.83% 0.19% 0.64% 0.00% -284 98.51% 1.49% 0.47% 1.02% 0.00%
-349 99.17% 0.83% 0.19% 0.64% 0.00% -283 98.50% 1.50% 0.47% 1.03% 0.00%
-348 99.16% 0.84% 0.20% 0.65% 0.00% -282 98.49% 1.51% 0.48% 1.03% 0.00%
-347 99.15% 0.85% 0.20% 0.65% 0.00% -281 98.47% 1.53% 0.49% 1.04% 0.00%
-346 99.14% 0.86% 0.20% 0.66% 0.00% -280 98.45% 1.55% 0.50% 1.05% 0.00%
-345 99.13% 0.87% 0.20% 0.66% 0.00% -279 98.44% 1.56% 0.51% 1.05% 0.00%
-344 99.13% 0.87% 0.21% 0.67% 0.00% -278 98.43% 1.57% 0.51% 1.06% 0.00%
-343 99.13% 0.88% 0.21% 0.67% 0.00% -277 98.42% 1.58% 0.52% 1.06% 0.00%
-342 99.11% 0.89% 0.21% 0.68% 0.00% -276 98.40% 1.60% 0.52% 1.08% 0.00%
-341 99.11% 0.89% 0.21% 0.68% 0.00% -275 98.39% 1.61% 0.53% 1.08% 0.00%
-340 99.10% 0.90% 0.22% 0.69% 0.00% -274 98.38% 1.62% 0.53% 1.09% 0.00%
-339 99.09% 0.91% 0.22% 0.69% 0.00% -273 98.37% 1.63% 0.54% 1.09% 0.00%
-338 99.08% 0.92% 0.22% 0.70% 0.00% -272 98.35% 1.65% 0.55% 1.10% 0.00%
-337 99.08% 0.92% 0.22% 0.70% 0.00% -271 98.35% 1.66% 0.55% 1.11% 0.00%
-336 99.07% 0.93% 0.23% 0.70% 0.00% -270 98.34% 1.66% 0.55% 1.11% 0.00%
-335 99.06% 0.95% 0.23% 0.71% 0.00% -269 98.32% 1.68% 0.56% 1.12% 0.00%
-334 99.05% 0.95% 0.24% 0.71% 0.00% -268 98.31% 1.69% 0.57% 1.12% 0.00%
-333 99.04% 0.96% 0.24% 0.72% 0.00% -267 98.30% 1.70% 0.57% 1.13% 0.00%
-332 99.03% 0.97% 0.25% 0.72% 0.00% -266 98.28% 1.72% 0.58% 1.14% 0.00%
-331 99.02% 0.98% 0.25% 0.73% 0.00% -265 98.27% 1.73% 0.59% 1.15% 0.00%
-330 99.01% 0.99% 0.26% 0.73% 0.00% -264 98.25% 1.75% 0.60% 1.15% 0.00%
-329 99.01% 0.99% 0.26% 0.74% 0.00% -263 98.23% 1.77% 0.61% 1.16% 0.00%
-328 99.00% 1.00% 0.26% 0.74% 0.00% -262 98.22% 1.78% 0.62% 1.17% 0.00%
-327 98.99% 1.01% 0.26% 0.75% 0.00% -261 98.20% 1.80% 0.62% 1.18% 0.00%
-326 98.98% 1.02% 0.27% 0.76% 0.00% -260 98.18% 1.82% 0.64% 1.19% 0.00%
-325 98.97% 1.03% 0.27% 0.76% 0.00% -259 98.17% 1.83% 0.64% 1.19% 0.00%
-324 98.96% 1.04% 0.27% 0.77% 0.00% -258 98.15% 1.85% 0.65% 1.20% 0.00%
-323 98.95% 1.05% 0.28% 0.78% 0.00% -257 98.13% 1.87% 0.66% 1.21% 0.00%
-322 98.95% 1.06% 0.28% 0.78% 0.00% -256 98.12% 1.88% 0.67% 1.21% 0.00%
-321 98.94% 1.06% 0.28% 0.78% 0.00% -255 98.10% 1.90% 0.68% 1.22% 0.00%
-320 98.93% 1.07% 0.28% 0.79% 0.00% -254 98.09% 1.91% 0.69% 1.23% 0.00%
-319 98.92% 1.08% 0.29% 0.79% 0.00% -253 98.07% 1.93% 0.69% 1.24% 0.00%
-318 98.91% 1.09% 0.29% 0.80% 0.00% -252 98.06% 1.94% 0.70% 1.25% 0.00%
-317 98.91% 1.09% 0.29% 0.80% 0.00% -251 98.04% 1.96% 0.70% 1.26% 0.00%
-316 98.89% 1.11% 0.29% 0.81% 0.00% -250 98.01% 1.99% 0.71% 1.27% 0.00%
-315 98.89% 1.11% 0.30% 0.82% 0.00% -249 97.99% 2.01% 0.72% 1.28% 0.00%
-314 98.88% 1.12% 0.30% 0.82% 0.00% -248 97.97% 2.03% 0.74% 1.30% 0.00%
-313 98.87% 1.13% 0.30% 0.82% 0.00% -247 97.95% 2.05% 0.75% 1.30% 0.00%
-312 98.86% 1.14% 0.31% 0.83% 0.00% -246 97.94% 2.07% 0.75% 1.31% 0.00%
-311 98.86% 1.15% 0.31% 0.84% 0.00% -245 97.92% 2.08% 0.76% 1.33% 0.00%
-310 98.85% 1.15% 0.32% 0.84% 0.00% -244 97.90% 2.10% 0.77% 1.34% 0.00%
-309 98.83% 1.17% 0.32% 0.85% 0.00% -243 97.88% 2.12% 0.78% 1.34% 0.00%
-308 98.82% 1.18% 0.33% 0.85% 0.00% -242 97.86% 2.14% 0.79% 1.35% 0.00%
-307 98.81% 1.19% 0.33% 0.87% 0.00% -241 97.84% 2.16% 0.80% 1.36% 0.00%
245
-240 97.81% 2.19% 0.82% 1.38% 0.00% -174 95.60% 4.40% 1.92% 2.48% 0.00%
-239 97.78% 2.22% 0.83% 1.39% 0.00% -173 95.54% 4.46% 1.94% 2.51% 0.00%
-238 97.76% 2.24% 0.84% 1.40% 0.00% -172 95.49% 4.51% 1.97% 2.55% 0.00%
-237 97.74% 2.26% 0.85% 1.42% 0.00% -171 95.45% 4.56% 1.99% 2.57% 0.00%
-236 97.70% 2.30% 0.86% 1.43% 0.00% -170 95.40% 4.60% 2.01% 2.59% 0.00%
-235 97.68% 2.32% 0.87% 1.45% 0.00% -169 95.34% 4.66% 2.04% 2.62% 0.00%
-234 97.65% 2.35% 0.89% 1.47% 0.00% -168 95.30% 4.70% 2.06% 2.63% 0.00%
-233 97.63% 2.37% 0.90% 1.48% 0.00% -167 95.25% 4.75% 2.09% 2.66% 0.00%
-232 97.60% 2.40% 0.92% 1.49% 0.00% -166 95.21% 4.79% 2.11% 2.68% 0.00%
-231 97.57% 2.43% 0.93% 1.50% 0.00% -165 95.18% 4.82% 2.13% 2.70% 0.00%
-230 97.54% 2.46% 0.95% 1.51% 0.00% -164 95.14% 4.86% 2.14% 2.72% 0.00%
-229 97.52% 2.49% 0.96% 1.52% 0.00% -163 95.09% 4.91% 2.17% 2.75% 0.00%
-228 97.49% 2.51% 0.98% 1.54% 0.00% -162 95.04% 4.96% 2.19% 2.77% 0.00%
-227 97.46% 2.54% 0.99% 1.55% 0.00% -161 94.98% 5.02% 2.22% 2.80% 0.00%
-226 97.43% 2.57% 1.00% 1.57% 0.00% -160 94.93% 5.07% 2.24% 2.83% 0.00%
-225 97.41% 2.60% 1.01% 1.58% 0.00% -159 94.88% 5.12% 2.26% 2.86% 0.00%
-224 97.38% 2.62% 1.02% 1.60% 0.00% -158 94.83% 5.17% 2.29% 2.89% 0.00%
-223 97.36% 2.64% 1.04% 1.61% 0.00% -157 94.78% 5.23% 2.31% 2.91% 0.00%
-222 97.34% 2.67% 1.05% 1.62% 0.00% -156 94.71% 5.29% 2.34% 2.95% 0.00%
-221 97.31% 2.69% 1.06% 1.63% 0.00% -155 94.65% 5.35% 2.37% 2.98% 0.00%
-220 97.29% 2.72% 1.07% 1.64% 0.00% -154 94.60% 5.40% 2.39% 3.01% 0.00%
-219 97.25% 2.75% 1.09% 1.66% 0.00% -153 94.55% 5.45% 2.40% 3.05% 0.00%
-218 97.23% 2.77% 1.10% 1.67% 0.00% -152 94.50% 5.50% 2.43% 3.07% 0.00%
-217 97.20% 2.80% 1.12% 1.69% 0.00% -151 94.45% 5.55% 2.44% 3.10% 0.00%
-216 97.16% 2.84% 1.14% 1.70% 0.00% -150 94.41% 5.59% 2.46% 3.13% 0.00%
-215 97.14% 2.86% 1.15% 1.71% 0.00% -149 94.36% 5.64% 2.49% 3.15% 0.00%
-214 97.11% 2.90% 1.16% 1.73% 0.00% -148 94.30% 5.70% 2.51% 3.19% 0.00%
-213 97.07% 2.93% 1.18% 1.74% 0.00% -147 94.22% 5.78% 2.55% 3.23% 0.00%
-212 97.05% 2.95% 1.20% 1.75% 0.00% -146 94.16% 5.84% 2.57% 3.27% 0.00%
-211 97.02% 2.98% 1.21% 1.77% 0.00% -145 94.08% 5.92% 2.61% 3.31% 0.00%
-210 96.99% 3.01% 1.22% 1.79% 0.00% -144 94.01% 5.99% 2.64% 3.35% 0.00%
-209 96.96% 3.04% 1.23% 1.81% 0.00% -143 93.94% 6.06% 2.67% 3.39% 0.00%
-208 96.93% 3.07% 1.25% 1.82% 0.00% -142 93.86% 6.14% 2.70% 3.43% 0.00%
-207 96.90% 3.10% 1.27% 1.84% 0.00% -141 93.79% 6.21% 2.73% 3.48% 0.00%
-206 96.86% 3.14% 1.29% 1.85% 0.00% -140 93.74% 6.26% 2.76% 3.51% 0.00%
-205 96.83% 3.18% 1.31% 1.87% 0.00% -139 93.67% 6.33% 2.78% 3.55% 0.00%
-204 96.79% 3.21% 1.33% 1.88% 0.00% -138 93.60% 6.40% 2.81% 3.59% 0.00%
-203 96.76% 3.24% 1.34% 1.89% 0.00% -137 93.53% 6.47% 2.83% 3.64% 0.00%
-202 96.72% 3.28% 1.36% 1.91% 0.00% -136 93.47% 6.53% 2.86% 3.67% 0.00%
-201 96.69% 3.31% 1.38% 1.93% 0.00% -135 93.41% 6.59% 2.88% 3.71% 0.00%
-200 96.66% 3.34% 1.39% 1.94% 0.00% -134 93.35% 6.65% 2.92% 3.73% 0.00%
-199 96.62% 3.38% 1.42% 1.96% 0.00% -133 93.27% 6.73% 2.96% 3.78% 0.00%
-198 96.58% 3.42% 1.43% 1.99% 0.00% -132 93.20% 6.80% 2.99% 3.81% 0.00%
-197 96.54% 3.46% 1.46% 2.00% 0.00% -131 93.14% 6.86% 3.01% 3.85% 0.00%
-196 96.50% 3.50% 1.48% 2.02% 0.00% -130 93.06% 6.94% 3.04% 3.90% 0.00%
-195 96.47% 3.53% 1.49% 2.03% 0.00% -129 93.00% 7.00% 3.06% 3.94% 0.00%
-194 96.44% 3.56% 1.51% 2.05% 0.00% -128 92.94% 7.06% 3.08% 3.98% 0.00%
-193 96.41% 3.59% 1.53% 2.07% 0.00% -127 92.88% 7.12% 3.11% 4.01% 0.00%
-192 96.37% 3.63% 1.55% 2.08% 0.00% -126 92.80% 7.20% 3.15% 4.05% 0.00%
-191 96.34% 3.66% 1.56% 2.10% 0.00% -125 92.71% 7.29% 3.19% 4.09% 0.00%
-190 96.29% 3.71% 1.59% 2.12% 0.00% -124 92.63% 7.37% 3.23% 4.15% 0.00%
-189 96.25% 3.75% 1.61% 2.14% 0.00% -123 92.55% 7.45% 3.26% 4.19% 0.00%
-188 96.21% 3.79% 1.63% 2.16% 0.00% -122 92.47% 7.53% 3.29% 4.24% 0.00%
-187 96.17% 3.83% 1.65% 2.18% 0.00% -121 92.40% 7.60% 3.31% 4.28% 0.00%
-186 96.13% 3.87% 1.66% 2.20% 0.00% -120 92.35% 7.66% 3.34% 4.31% 0.00%
-185 96.09% 3.91% 1.69% 2.22% 0.00% -119 92.27% 7.73% 3.37% 4.36% 0.00%
-184 96.05% 3.95% 1.71% 2.25% 0.00% -118 92.20% 7.81% 3.39% 4.41% 0.00%
-183 96.01% 3.99% 1.72% 2.27% 0.00% -117 92.12% 7.88% 3.43% 4.46% 0.00%
-182 95.97% 4.03% 1.74% 2.29% 0.00% -116 92.05% 7.96% 3.45% 4.50% 0.00%
-181 95.93% 4.07% 1.76% 2.31% 0.00% -115 91.96% 8.04% 3.48% 4.55% 0.00%
-180 95.87% 4.13% 1.79% 2.33% 0.00% -114 91.90% 8.10% 3.51% 4.59% 0.00%
-179 95.83% 4.17% 1.81% 2.36% 0.00% -113 91.82% 8.18% 3.54% 4.64% 0.01%
-178 95.78% 4.22% 1.84% 2.38% 0.00% -112 91.71% 8.29% 3.58% 4.70% 0.01%
-177 95.73% 4.27% 1.86% 2.41% 0.00% -111 91.64% 8.36% 3.60% 4.75% 0.01%
-176 95.68% 4.32% 1.89% 2.44% 0.00% -110 91.55% 8.45% 3.64% 4.80% 0.01%
-175 95.63% 4.37% 1.90% 2.47% 0.00% -109 91.46% 8.54% 3.67% 4.86% 0.01%
246
-108 91.39% 8.61% 3.70% 4.90% 0.01% -42 84.11% 15.90% 6.15% 9.34% 0.40%
-107 91.31% 8.69% 3.72% 4.96% 0.01% -41 83.97% 16.03% 6.19% 9.42% 0.41%
-106 91.24% 8.76% 3.75% 5.01% 0.01% -40 83.83% 16.17% 6.23% 9.51% 0.43%
-105 91.15% 8.85% 3.78% 5.06% 0.01% -39 83.69% 16.32% 6.28% 9.60% 0.44%
-104 91.06% 8.94% 3.82% 5.11% 0.01% -38 83.57% 16.43% 6.31% 9.67% 0.46%
-103 90.97% 9.03% 3.85% 5.17% 0.01% -37 83.43% 16.57% 6.35% 9.75% 0.46%
-102 90.88% 9.12% 3.88% 5.24% 0.01% -36 83.28% 16.72% 6.39% 9.85% 0.48%
-101 90.77% 9.23% 3.92% 5.30% 0.01% -35 83.13% 16.88% 6.43% 9.95% 0.50%
-100 90.67% 9.33% 3.95% 5.36% 0.01% -34 82.99% 17.01% 6.47% 10.02% 0.51%
-99 90.59% 9.41% 3.98% 5.41% 0.02% -33 82.84% 17.17% 6.52% 10.11% 0.53%
-98 90.47% 9.53% 4.02% 5.49% 0.02% -32 82.67% 17.33% 6.56% 10.22% 0.55%
-97 90.38% 9.62% 4.05% 5.54% 0.02% -31 82.52% 17.48% 6.61% 10.31% 0.57%
-96 90.29% 9.71% 4.08% 5.60% 0.03% -30 82.37% 17.63% 6.66% 10.39% 0.58%
-95 90.19% 9.81% 4.12% 5.66% 0.03% -29 82.21% 17.80% 6.70% 10.49% 0.60%
-94 90.09% 9.91% 4.15% 5.73% 0.03% -28 82.08% 17.92% 6.73% 10.58% 0.61%
-93 89.98% 10.02% 4.19% 5.80% 0.03% -27 81.94% 18.06% 6.77% 10.66% 0.63%
-92 89.91% 10.09% 4.22% 5.85% 0.03% -26 81.79% 18.21% 6.81% 10.76% 0.65%
-91 89.81% 10.19% 4.24% 5.91% 0.03% -25 81.61% 18.39% 6.85% 10.88% 0.66%
-90 89.71% 10.29% 4.28% 5.97% 0.04% -24 81.45% 18.56% 6.90% 10.98% 0.68%
-89 89.61% 10.39% 4.32% 6.03% 0.04% -23 81.31% 18.69% 6.93% 11.07% 0.69%
-88 89.52% 10.48% 4.35% 6.09% 0.05% -22 81.17% 18.83% 6.97% 11.16% 0.70%
-87 89.43% 10.57% 4.39% 6.14% 0.05% -21 81.04% 18.97% 7.01% 11.24% 0.72%
-86 89.33% 10.67% 4.43% 6.19% 0.05% -20 80.87% 19.13% 7.05% 11.34% 0.74%
-85 89.24% 10.76% 4.46% 6.25% 0.06% -19 80.71% 19.30% 7.09% 11.45% 0.76%
-84 89.14% 10.87% 4.49% 6.31% 0.06% -18 80.55% 19.45% 7.13% 11.54% 0.78%
-83 89.04% 10.96% 4.53% 6.37% 0.06% -17 80.39% 19.61% 7.18% 11.63% 0.80%
-82 88.94% 11.06% 4.57% 6.43% 0.06% -16 80.23% 19.77% 7.23% 11.73% 0.82%
-81 88.84% 11.16% 4.60% 6.50% 0.07% -15 80.07% 19.93% 7.28% 11.82% 0.83%
-80 88.72% 11.28% 4.63% 6.57% 0.07% -14 79.92% 20.08% 7.32% 11.90% 0.86%
-79 88.62% 11.39% 4.67% 6.63% 0.08% -13 79.78% 20.22% 7.36% 11.98% 0.88%
-78 88.51% 11.50% 4.71% 6.69% 0.09% -12 79.63% 20.37% 7.40% 12.06% 0.91%
-77 88.40% 11.60% 4.74% 6.76% 0.10% -11 79.47% 20.53% 7.44% 12.16% 0.93%
-76 88.27% 11.73% 4.78% 6.84% 0.10% -10 79.30% 20.70% 7.49% 12.27% 0.94%
-75 88.17% 11.83% 4.82% 6.90% 0.11% -9 79.13% 20.87% 7.53% 12.37% 0.96%
-74 88.04% 11.96% 4.86% 6.98% 0.12% -8 78.95% 21.06% 7.59% 12.48% 0.99%
-73 87.93% 12.07% 4.90% 7.05% 0.12% -7 78.77% 21.23% 7.64% 12.58% 1.02%
-72 87.82% 12.18% 4.94% 7.11% 0.13% -6 78.61% 21.39% 7.69% 12.66% 1.04%
-71 87.71% 12.29% 4.98% 7.18% 0.14% -5 78.43% 21.57% 7.73% 12.77% 1.07%
-70 87.59% 12.41% 5.01% 7.26% 0.14% -4 78.28% 21.73% 7.79% 12.85% 1.09%
-69 87.47% 12.53% 5.05% 7.32% 0.15% -3 78.13% 21.87% 7.82% 12.93% 1.12%
-68 87.37% 12.63% 5.09% 7.39% 0.16% -2 77.98% 22.02% 7.87% 13.00% 1.15%
-67 87.25% 12.75% 5.13% 7.46% 0.16% -1 77.83% 22.18% 7.91% 13.10% 1.17%
-66 87.13% 12.87% 5.16% 7.54% 0.18% 0 77.25% 22.75% 7.96% 13.55% 1.24%
-65 87.02% 12.99% 5.19% 7.61% 0.19% 1 77.10% 22.91% 8.00% 13.64% 1.27%
-64 86.92% 13.08% 5.22% 7.67% 0.19% 2 76.82% 23.18% 8.04% 13.83% 1.31%
-63 86.80% 13.21% 5.27% 7.74% 0.20% 3 76.63% 23.37% 8.08% 13.95% 1.34%
-62 86.67% 13.34% 5.32% 7.81% 0.21% 4 76.45% 23.55% 8.12% 14.05% 1.38%
-61 86.56% 13.44% 5.35% 7.88% 0.21% 5 76.27% 23.73% 8.17% 14.15% 1.42%
-60 86.45% 13.55% 5.40% 7.93% 0.22% 6 76.09% 23.91% 8.21% 14.26% 1.44%
-59 86.33% 13.67% 5.44% 8.01% 0.23% 7 75.90% 24.10% 8.26% 14.36% 1.48%
-58 86.20% 13.80% 5.48% 8.08% 0.24% 8 75.74% 24.26% 8.30% 14.45% 1.51%
-57 86.06% 13.94% 5.53% 8.16% 0.25% 9 75.56% 24.44% 8.35% 14.54% 1.55%
-56 85.95% 14.05% 5.56% 8.22% 0.27% 10 75.41% 24.59% 8.40% 14.61% 1.58%
-55 85.82% 14.18% 5.61% 8.29% 0.28% 11 75.23% 24.77% 8.45% 14.71% 1.61%
-54 85.70% 14.30% 5.64% 8.37% 0.28% 12 75.07% 24.93% 8.49% 14.80% 1.63%
-53 85.58% 14.42% 5.68% 8.45% 0.29% 13 74.91% 25.09% 8.53% 14.88% 1.68%
-52 85.44% 14.57% 5.73% 8.54% 0.30% 14 74.72% 25.29% 8.58% 15.00% 1.71%
-51 85.34% 14.67% 5.76% 8.60% 0.30% 15 74.56% 25.44% 8.63% 15.08% 1.74%
-50 85.20% 14.80% 5.81% 8.68% 0.31% 16 74.34% 25.66% 8.68% 15.20% 1.77%
-49 85.06% 14.94% 5.85% 8.76% 0.33% 17 74.19% 25.81% 8.73% 15.29% 1.80%
-48 84.91% 15.09% 5.89% 8.86% 0.34% 18 74.05% 25.95% 8.77% 15.36% 1.82%
-47 84.77% 15.23% 5.94% 8.95% 0.35% 19 73.85% 26.15% 8.82% 15.48% 1.86%
-46 84.64% 15.36% 5.98% 9.03% 0.35% 20 73.67% 26.33% 8.87% 15.57% 1.89%
-45 84.51% 15.49% 6.02% 9.11% 0.36% 21 73.50% 26.50% 8.91% 15.67% 1.92%
-44 84.38% 15.63% 6.06% 9.18% 0.38% 22 73.33% 26.67% 8.97% 15.75% 1.95%
-43 84.24% 15.76% 6.10% 9.27% 0.39% 23 73.16% 26.84% 9.02% 15.84% 1.98%
247
24 72.99% 27.01% 9.08% 15.93% 2.00% 90 62.11% 37.89% 12.43% 21.81% 3.65%
25 72.80% 27.20% 9.12% 16.03% 2.05% 91 61.95% 38.05% 12.48% 21.90% 3.68%
26 72.61% 27.39% 9.17% 16.14% 2.08% 92 61.79% 38.22% 12.53% 21.99% 3.70%
27 72.44% 27.56% 9.22% 16.23% 2.11% 93 61.64% 38.36% 12.58% 22.07% 3.71%
28 72.26% 27.74% 9.28% 16.32% 2.14% 94 61.47% 38.53% 12.63% 22.16% 3.74%
29 72.08% 27.92% 9.33% 16.42% 2.17% 95 61.31% 38.69% 12.68% 22.25% 3.76%
30 71.91% 28.09% 9.39% 16.50% 2.20% 96 61.14% 38.86% 12.73% 22.34% 3.78%
31 71.73% 28.27% 9.44% 16.59% 2.25% 97 60.98% 39.02% 12.78% 22.44% 3.81%
32 71.54% 28.46% 9.49% 16.68% 2.28% 98 60.81% 39.19% 12.83% 22.53% 3.83%
33 71.36% 28.64% 9.54% 16.78% 2.32% 99 60.64% 39.36% 12.88% 22.63% 3.85%
34 71.19% 28.81% 9.57% 16.88% 2.36% 100 60.48% 39.52% 12.94% 22.71% 3.87%
35 71.03% 28.97% 9.60% 16.98% 2.38% 101 60.33% 39.67% 12.98% 22.80% 3.89%
36 70.88% 29.12% 9.64% 17.07% 2.41% 102 60.17% 39.83% 13.03% 22.90% 3.90%
37 70.71% 29.29% 9.69% 17.17% 2.43% 103 60.02% 39.98% 13.08% 22.98% 3.92%
38 70.54% 29.46% 9.74% 17.26% 2.46% 104 59.86% 40.14% 13.13% 23.07% 3.95%
39 70.38% 29.62% 9.79% 17.34% 2.49% 105 59.71% 40.29% 13.17% 23.15% 3.97%
40 70.21% 29.79% 9.84% 17.44% 2.52% 106 59.57% 40.43% 13.21% 23.24% 3.98%
41 70.03% 29.97% 9.89% 17.53% 2.55% 107 59.39% 40.61% 13.27% 23.33% 4.01%
42 69.84% 30.16% 9.96% 17.62% 2.58% 108 59.23% 40.77% 13.32% 23.42% 4.03%
43 69.68% 30.32% 10.01% 17.70% 2.61% 109 59.05% 40.95% 13.38% 23.51% 4.06%
44 69.53% 30.47% 10.06% 17.77% 2.64% 110 58.90% 41.10% 13.43% 23.59% 4.08%
45 69.35% 30.65% 10.11% 17.87% 2.67% 111 58.74% 41.26% 13.48% 23.68% 4.10%
46 69.16% 30.84% 10.17% 17.97% 2.71% 112 58.59% 41.41% 13.51% 23.78% 4.13%
47 68.97% 31.03% 10.23% 18.08% 2.73% 113 58.43% 41.57% 13.55% 23.86% 4.16%
48 68.79% 31.21% 10.28% 18.17% 2.77% 114 58.28% 41.72% 13.59% 23.95% 4.18%
49 68.64% 31.36% 10.33% 18.25% 2.79% 115 58.13% 41.87% 13.64% 24.04% 4.20%
50 68.47% 31.54% 10.38% 18.34% 2.81% 116 57.99% 42.02% 13.69% 24.12% 4.21%
51 68.30% 31.70% 10.43% 18.43% 2.84% 117 57.85% 42.15% 13.73% 24.19% 4.23%
52 68.14% 31.86% 10.48% 18.52% 2.87% 118 57.73% 42.27% 13.77% 24.26% 4.25%
53 67.98% 32.02% 10.52% 18.60% 2.90% 119 57.59% 42.41% 13.81% 24.34% 4.27%
54 67.83% 32.18% 10.57% 18.68% 2.92% 120 57.41% 42.59% 13.86% 24.45% 4.29%
55 67.66% 32.34% 10.64% 18.77% 2.93% 121 57.26% 42.74% 13.91% 24.52% 4.31%
56 67.51% 32.49% 10.69% 18.84% 2.95% 122 57.10% 42.90% 13.96% 24.61% 4.33%
57 67.36% 32.64% 10.75% 18.93% 2.96% 123 56.95% 43.06% 14.01% 24.70% 4.36%
58 67.21% 32.79% 10.79% 19.01% 2.99% 124 56.81% 43.20% 14.03% 24.78% 4.38%
59 67.04% 32.96% 10.85% 19.10% 3.02% 125 56.66% 43.34% 14.08% 24.87% 4.40%
60 66.86% 33.14% 10.92% 19.19% 3.03% 126 56.50% 43.51% 14.12% 24.97% 4.41%
61 66.71% 33.30% 10.97% 19.27% 3.05% 127 56.35% 43.65% 14.17% 25.05% 4.43%
62 66.53% 33.47% 11.03% 19.37% 3.08% 128 56.19% 43.81% 14.23% 25.14% 4.44%
63 66.35% 33.65% 11.09% 19.46% 3.10% 129 56.04% 43.96% 14.27% 25.23% 4.47%
64 66.20% 33.80% 11.13% 19.55% 3.12% 130 55.90% 44.10% 14.32% 25.30% 4.48%
65 66.05% 33.95% 11.18% 19.63% 3.15% 131 55.76% 44.24% 14.36% 25.39% 4.50%
66 65.88% 34.12% 11.23% 19.72% 3.17% 132 55.62% 44.38% 14.40% 25.46% 4.52%
67 65.72% 34.28% 11.28% 19.80% 3.20% 133 55.46% 44.55% 14.44% 25.56% 4.54%
68 65.55% 34.45% 11.34% 19.88% 3.22% 134 55.30% 44.70% 14.49% 25.65% 4.56%
69 65.40% 34.60% 11.40% 19.97% 3.24% 135 55.15% 44.85% 14.53% 25.74% 4.59%
70 65.22% 34.78% 11.46% 20.06% 3.26% 136 55.01% 44.99% 14.57% 25.82% 4.61%
71 65.07% 34.93% 11.51% 20.15% 3.28% 137 54.86% 45.14% 14.60% 25.91% 4.63%
72 64.91% 35.09% 11.55% 20.23% 3.30% 138 54.71% 45.29% 14.65% 25.99% 4.65%
73 64.77% 35.23% 11.60% 20.31% 3.32% 139 54.55% 45.45% 14.69% 26.07% 4.68%
74 64.60% 35.40% 11.66% 20.40% 3.34% 140 54.42% 45.58% 14.74% 26.15% 4.70%
75 64.46% 35.54% 11.70% 20.48% 3.36% 141 54.29% 45.71% 14.76% 26.23% 4.72%
76 64.31% 35.70% 11.74% 20.57% 3.38% 142 54.14% 45.86% 14.81% 26.31% 4.74%
77 64.14% 35.86% 11.79% 20.67% 3.41% 143 54.00% 46.00% 14.85% 26.40% 4.76%
78 63.96% 36.04% 11.84% 20.77% 3.43% 144 53.86% 46.14% 14.89% 26.48% 4.78%
79 63.81% 36.19% 11.89% 20.86% 3.45% 145 53.72% 46.28% 14.93% 26.55% 4.80%
80 63.64% 36.36% 11.93% 20.96% 3.47% 146 53.57% 46.43% 14.97% 26.64% 4.82%
81 63.49% 36.51% 11.98% 21.04% 3.49% 147 53.42% 46.59% 15.01% 26.73% 4.85%
82 63.34% 36.66% 12.03% 21.13% 3.51% 148 53.26% 46.74% 15.05% 26.82% 4.87%
83 63.17% 36.83% 12.07% 21.23% 3.53% 149 53.12% 46.88% 15.10% 26.90% 4.88%
84 62.99% 37.01% 12.13% 21.33% 3.55% 150 52.98% 47.02% 15.14% 26.97% 4.91%
85 62.86% 37.14% 12.19% 21.40% 3.56% 151 52.85% 47.15% 15.18% 27.04% 4.92%
86 62.69% 37.31% 12.24% 21.48% 3.58% 152 52.72% 47.28% 15.22% 27.12% 4.94%
87 62.54% 37.46% 12.28% 21.58% 3.60% 153 52.57% 47.43% 15.28% 27.20% 4.96%
88 62.39% 37.61% 12.33% 21.66% 3.62% 154 52.43% 47.58% 15.32% 27.28% 4.97%
89 62.26% 37.74% 12.38% 21.73% 3.64% 155 52.30% 47.70% 15.36% 27.34% 4.99%
248
156 52.15% 47.85% 15.40% 27.43% 5.02% 222 44.32% 55.68% 17.88% 31.59% 6.21%
157 52.01% 47.99% 15.45% 27.50% 5.04% 223 44.21% 55.79% 17.91% 31.65% 6.23%
158 51.85% 48.16% 15.51% 27.58% 5.07% 224 44.10% 55.90% 17.95% 31.71% 6.25%
159 51.71% 48.30% 15.55% 27.66% 5.09% 225 44.00% 56.01% 17.98% 31.75% 6.27%
160 51.57% 48.43% 15.59% 27.73% 5.11% 226 43.89% 56.11% 18.02% 31.81% 6.28%
161 51.44% 48.57% 15.62% 27.81% 5.14% 227 43.80% 56.20% 18.04% 31.86% 6.30%
162 51.31% 48.69% 15.66% 27.88% 5.15% 228 43.69% 56.31% 18.08% 31.91% 6.31%
163 51.17% 48.83% 15.69% 27.97% 5.17% 229 43.59% 56.41% 18.12% 31.96% 6.33%
164 51.03% 48.97% 15.74% 28.04% 5.19% 230 43.46% 56.54% 18.15% 32.03% 6.35%
165 50.93% 49.08% 15.77% 28.09% 5.21% 231 43.37% 56.63% 18.18% 32.08% 6.37%
166 50.78% 49.22% 15.81% 28.18% 5.23% 232 43.26% 56.74% 18.21% 32.14% 6.39%
167 50.66% 49.34% 15.84% 28.25% 5.25% 233 43.15% 56.85% 18.25% 32.20% 6.40%
168 50.54% 49.46% 15.88% 28.31% 5.28% 234 43.05% 56.95% 18.28% 32.25% 6.42%
169 50.39% 49.61% 15.93% 28.39% 5.29% 235 42.97% 57.03% 18.31% 32.29% 6.44%
170 50.27% 49.73% 15.97% 28.45% 5.31% 236 42.86% 57.14% 18.34% 32.35% 6.45%
171 50.16% 49.84% 16.00% 28.52% 5.32% 237 42.77% 57.23% 18.37% 32.40% 6.47%
172 50.05% 49.95% 16.03% 28.58% 5.34% 238 42.67% 57.33% 18.40% 32.45% 6.48%
173 49.93% 50.07% 16.08% 28.64% 5.35% 239 42.58% 57.43% 18.43% 32.50% 6.49%
174 49.79% 50.21% 16.11% 28.72% 5.38% 240 42.48% 57.52% 18.46% 32.56% 6.51%
175 49.68% 50.32% 16.15% 28.78% 5.39% 241 42.39% 57.61% 18.48% 32.60% 6.53%
176 49.55% 50.46% 16.19% 28.85% 5.41% 242 42.31% 57.69% 18.51% 32.64% 6.54%
177 49.40% 50.60% 16.24% 28.92% 5.44% 243 42.20% 57.80% 18.55% 32.69% 6.57%
178 49.28% 50.72% 16.28% 28.99% 5.45% 244 42.08% 57.92% 18.58% 32.76% 6.59%
179 49.16% 50.84% 16.32% 29.05% 5.47% 245 41.98% 58.02% 18.60% 32.82% 6.61%
180 49.04% 50.96% 16.36% 29.12% 5.48% 246 41.88% 58.12% 18.63% 32.87% 6.62%
181 48.92% 51.09% 16.40% 29.18% 5.51% 247 41.78% 58.22% 18.65% 32.93% 6.63%
182 48.81% 51.19% 16.43% 29.24% 5.52% 248 41.70% 58.30% 18.67% 32.98% 6.65%
183 48.70% 51.30% 16.47% 29.29% 5.54% 249 41.59% 58.41% 18.71% 33.03% 6.67%
184 48.59% 51.41% 16.51% 29.35% 5.55% 250 41.50% 58.50% 18.74% 33.08% 6.68%
185 48.49% 51.51% 16.54% 29.40% 5.58% 251 41.41% 58.59% 18.78% 33.12% 6.69%
186 48.37% 51.63% 16.58% 29.46% 5.60% 252 41.32% 58.68% 18.81% 33.16% 6.71%
187 48.25% 51.75% 16.61% 29.52% 5.61% 253 41.23% 58.77% 18.84% 33.21% 6.72%
188 48.14% 51.86% 16.65% 29.58% 5.63% 254 41.14% 58.86% 18.88% 33.25% 6.73%
189 48.03% 51.97% 16.69% 29.65% 5.64% 255 41.06% 58.94% 18.90% 33.29% 6.75%
190 47.91% 52.09% 16.73% 29.70% 5.66% 256 40.98% 59.02% 18.92% 33.33% 6.76%
191 47.78% 52.22% 16.77% 29.76% 5.69% 257 40.89% 59.11% 18.95% 33.38% 6.78%
192 47.65% 52.35% 16.81% 29.83% 5.70% 258 40.79% 59.21% 18.98% 33.44% 6.79%
193 47.55% 52.45% 16.84% 29.88% 5.73% 259 40.69% 59.31% 19.02% 33.49% 6.81%
194 47.43% 52.57% 16.87% 29.95% 5.75% 260 40.60% 59.40% 19.04% 33.54% 6.82%
195 47.32% 52.68% 16.91% 30.01% 5.77% 261 40.51% 59.49% 19.07% 33.60% 6.83%
196 47.20% 52.80% 16.95% 30.06% 5.78% 262 40.43% 59.57% 19.09% 33.63% 6.84%
197 47.10% 52.90% 16.99% 30.12% 5.80% 263 40.33% 59.67% 19.13% 33.70% 6.85%
198 46.99% 53.01% 17.03% 30.17% 5.81% 264 40.23% 59.77% 19.16% 33.74% 6.87%
199 46.87% 53.13% 17.06% 30.24% 5.83% 265 40.15% 59.85% 19.19% 33.78% 6.87%
200 46.76% 53.24% 17.11% 30.30% 5.84% 266 40.05% 59.95% 19.23% 33.84% 6.89%
201 46.66% 53.34% 17.14% 30.35% 5.84% 267 39.97% 60.03% 19.25% 33.88% 6.90%
202 46.54% 53.46% 17.18% 30.41% 5.86% 268 39.85% 60.15% 19.29% 33.94% 6.92%
203 46.43% 53.57% 17.22% 30.47% 5.88% 269 39.76% 60.24% 19.32% 33.99% 6.93%
204 46.33% 53.67% 17.26% 30.52% 5.89% 270 39.67% 60.33% 19.35% 34.04% 6.94%
205 46.20% 53.80% 17.30% 30.59% 5.91% 271 39.60% 60.41% 19.37% 34.08% 6.95%
206 46.09% 53.92% 17.33% 30.66% 5.93% 272 39.51% 60.49% 19.40% 34.13% 6.96%
207 45.98% 54.02% 17.37% 30.70% 5.95% 273 39.41% 60.59% 19.43% 34.18% 6.97%
208 45.87% 54.13% 17.41% 30.77% 5.96% 274 39.30% 60.70% 19.46% 34.24% 7.00%
209 45.76% 54.24% 17.44% 30.82% 5.98% 275 39.21% 60.79% 19.49% 34.28% 7.01%
210 45.65% 54.35% 17.47% 30.88% 6.00% 276 39.13% 60.87% 19.51% 34.33% 7.03%
211 45.53% 54.47% 17.51% 30.94% 6.02% 277 39.05% 60.96% 19.54% 34.37% 7.04%
212 45.42% 54.58% 17.54% 31.00% 6.04% 278 38.96% 61.04% 19.57% 34.41% 7.06%
213 45.31% 54.69% 17.58% 31.06% 6.05% 279 38.88% 61.13% 19.60% 34.45% 7.07%
214 45.21% 54.79% 17.61% 31.11% 6.07% 280 38.79% 61.22% 19.63% 34.51% 7.08%
215 45.10% 54.90% 17.65% 31.16% 6.09% 281 38.70% 61.30% 19.66% 34.54% 7.09%
216 44.98% 55.02% 17.68% 31.23% 6.10% 282 38.62% 61.38% 19.69% 34.58% 7.11%
217 44.86% 55.14% 17.71% 31.30% 6.12% 283 38.55% 61.45% 19.71% 34.63% 7.12%
218 44.75% 55.25% 17.75% 31.37% 6.14% 284 38.45% 61.55% 19.73% 34.69% 7.13%
219 44.66% 55.34% 17.78% 31.42% 6.15% 285 38.36% 61.64% 19.76% 34.73% 7.14%
220 44.56% 55.44% 17.81% 31.47% 6.16% 286 38.27% 61.73% 19.79% 34.78% 7.16%
221 44.44% 55.56% 17.84% 31.53% 6.19% 287 38.19% 61.81% 19.82% 34.83% 7.17%
249
288 38.10% 61.90% 19.86% 34.87% 7.18% 354 33.09% 66.91% 21.52% 37.44% 7.95%
289 37.99% 62.01% 19.90% 34.92% 7.19% 355 33.01% 66.99% 21.55% 37.49% 7.96%
290 37.89% 62.11% 19.93% 34.98% 7.20% 356 32.95% 67.05% 21.57% 37.52% 7.97%
291 37.82% 62.18% 19.96% 35.01% 7.21% 357 32.88% 67.12% 21.59% 37.55% 7.98%
292 37.74% 62.26% 19.98% 35.05% 7.22% 358 32.82% 67.18% 21.61% 37.58% 7.99%
293 37.66% 62.34% 20.01% 35.09% 7.24% 359 32.76% 67.24% 21.63% 37.61% 8.00%
294 37.57% 62.43% 20.03% 35.14% 7.26% 360 32.70% 67.30% 21.65% 37.65% 8.01%
295 37.49% 62.51% 20.06% 35.18% 7.27% 361 32.63% 67.37% 21.67% 37.68% 8.02%
296 37.41% 62.59% 20.09% 35.22% 7.29% 362 32.57% 67.43% 21.69% 37.71% 8.03%
297 37.33% 62.67% 20.12% 35.25% 7.30% 363 32.50% 67.50% 21.71% 37.74% 8.04%
298 37.26% 62.74% 20.14% 35.29% 7.31% 364 32.43% 67.57% 21.74% 37.79% 8.05%
299 37.17% 62.83% 20.16% 35.35% 7.32% 365 32.35% 67.65% 21.77% 37.83% 8.06%
300 37.10% 62.90% 20.19% 35.38% 7.33% 366 32.28% 67.72% 21.79% 37.86% 8.07%
301 37.02% 62.98% 20.21% 35.42% 7.34% 367 32.21% 67.79% 21.81% 37.90% 8.08%
302 36.93% 63.07% 20.24% 35.47% 7.36% 368 32.14% 67.86% 21.83% 37.94% 8.09%
303 36.84% 63.17% 20.27% 35.52% 7.37% 369 32.07% 67.93% 21.86% 37.97% 8.10%
304 36.77% 63.23% 20.30% 35.55% 7.38% 370 32.01% 67.99% 21.88% 38.01% 8.10%
305 36.69% 63.31% 20.33% 35.59% 7.39% 371 31.96% 68.05% 21.90% 38.04% 8.11%
306 36.60% 63.40% 20.36% 35.64% 7.41% 372 31.89% 68.11% 21.92% 38.07% 8.12%
307 36.52% 63.48% 20.38% 35.68% 7.42% 373 31.81% 68.20% 21.95% 38.12% 8.13%
308 36.44% 63.56% 20.41% 35.71% 7.44% 374 31.75% 68.25% 21.97% 38.15% 8.13%
309 36.37% 63.64% 20.43% 35.76% 7.44% 375 31.69% 68.31% 21.98% 38.18% 8.14%
310 36.28% 63.72% 20.46% 35.81% 7.46% 376 31.62% 68.38% 22.00% 38.22% 8.15%
311 36.20% 63.80% 20.48% 35.85% 7.47% 377 31.57% 68.43% 22.02% 38.25% 8.16%
312 36.13% 63.87% 20.49% 35.89% 7.49% 378 31.50% 68.50% 22.05% 38.29% 8.17%
313 36.06% 63.94% 20.51% 35.93% 7.50% 379 31.43% 68.57% 22.07% 38.32% 8.18%
314 35.99% 64.01% 20.53% 35.97% 7.51% 380 31.37% 68.63% 22.09% 38.35% 8.19%
315 35.91% 64.09% 20.55% 36.02% 7.53% 381 31.29% 68.71% 22.12% 38.39% 8.20%
316 35.82% 64.18% 20.59% 36.06% 7.53% 382 31.21% 68.79% 22.15% 38.43% 8.21%
317 35.75% 64.25% 20.61% 36.10% 7.54% 383 31.15% 68.85% 22.17% 38.47% 8.21%
318 35.68% 64.32% 20.64% 36.12% 7.56% 384 31.09% 68.92% 22.19% 38.50% 8.22%
319 35.61% 64.39% 20.66% 36.16% 7.57% 385 31.02% 68.98% 22.22% 38.53% 8.23%
320 35.53% 64.47% 20.69% 36.20% 7.58% 386 30.95% 69.05% 22.24% 38.57% 8.24%
321 35.46% 64.55% 20.71% 36.24% 7.59% 387 30.87% 69.13% 22.27% 38.62% 8.24%
322 35.39% 64.61% 20.73% 36.28% 7.60% 388 30.81% 69.19% 22.29% 38.65% 8.25%
323 35.31% 64.69% 20.76% 36.32% 7.61% 389 30.76% 69.25% 22.31% 38.68% 8.26%
324 35.25% 64.75% 20.78% 36.35% 7.62% 390 30.71% 69.29% 22.32% 38.71% 8.26%
325 35.17% 64.83% 20.80% 36.40% 7.64% 391 30.65% 69.35% 22.34% 38.73% 8.27%
326 35.08% 64.92% 20.83% 36.44% 7.65% 392 30.60% 69.40% 22.36% 38.76% 8.28%
327 35.00% 65.00% 20.86% 36.47% 7.67% 393 30.53% 69.47% 22.39% 38.80% 8.29%
328 34.93% 65.07% 20.89% 36.51% 7.68% 394 30.47% 69.53% 22.41% 38.83% 8.30%
329 34.85% 65.15% 20.91% 36.54% 7.69% 395 30.40% 69.60% 22.43% 38.87% 8.31%
330 34.78% 65.22% 20.94% 36.58% 7.71% 396 30.34% 69.66% 22.44% 38.90% 8.31%
331 34.70% 65.30% 20.97% 36.62% 7.72% 397 30.29% 69.71% 22.47% 38.93% 8.32%
332 34.62% 65.38% 20.99% 36.66% 7.73% 398 30.23% 69.77% 22.49% 38.96% 8.33%
333 34.56% 65.44% 21.02% 36.69% 7.74% 399 30.15% 69.85% 22.51% 39.00% 8.33%
334 34.49% 65.51% 21.04% 36.72% 7.75% 400 30.10% 69.90% 22.54% 39.03% 8.34%
335 34.42% 65.58% 21.06% 36.76% 7.76% 401 30.05% 69.95% 22.56% 39.05% 8.35%
336 34.35% 65.65% 21.08% 36.79% 7.77% 402 29.99% 70.01% 22.57% 39.08% 8.35%
337 34.29% 65.71% 21.11% 36.82% 7.78% 403 29.95% 70.06% 22.59% 39.11% 8.36%
338 34.20% 65.80% 21.14% 36.87% 7.79% 404 29.88% 70.12% 22.60% 39.15% 8.36%
339 34.12% 65.88% 21.15% 36.91% 7.81% 405 29.83% 70.17% 22.62% 39.17% 8.37%
340 34.04% 65.96% 21.18% 36.95% 7.82% 406 29.78% 70.22% 22.64% 39.20% 8.38%
341 33.98% 66.02% 21.21% 36.98% 7.83% 407 29.72% 70.28% 22.66% 39.23% 8.38%
342 33.92% 66.09% 21.24% 37.01% 7.84% 408 29.66% 70.34% 22.68% 39.27% 8.39%
343 33.83% 66.17% 21.26% 37.06% 7.85% 409 29.61% 70.39% 22.70% 39.30% 8.39%
344 33.76% 66.24% 21.29% 37.10% 7.86% 410 29.55% 70.45% 22.72% 39.33% 8.40%
345 33.69% 66.31% 21.32% 37.13% 7.87% 411 29.50% 70.50% 22.73% 39.37% 8.40%
346 33.62% 66.38% 21.34% 37.16% 7.88% 412 29.43% 70.57% 22.75% 39.41% 8.41%
347 33.55% 66.45% 21.36% 37.20% 7.89% 413 29.37% 70.63% 22.78% 39.44% 8.42%
348 33.47% 66.53% 21.39% 37.24% 7.90% 414 29.30% 70.70% 22.80% 39.47% 8.43%
349 33.41% 66.59% 21.41% 37.28% 7.91% 415 29.25% 70.76% 22.82% 39.50% 8.43%
350 33.34% 66.66% 21.43% 37.31% 7.92% 416 29.20% 70.80% 22.83% 39.53% 8.44%
351 33.28% 66.72% 21.45% 37.34% 7.93% 417 29.15% 70.86% 22.86% 39.55% 8.45%
352 33.23% 66.78% 21.47% 37.37% 7.94% 418 29.09% 70.91% 22.88% 39.58% 8.45%
353 33.16% 66.84% 21.49% 37.40% 7.95% 419 29.04% 70.96% 22.90% 39.61% 8.46%
250
420 28.98% 71.02% 22.92% 39.63% 8.47% 486 25.66% 74.34% 24.11% 41.33% 8.90%
421 28.92% 71.08% 22.95% 39.66% 8.47% 487 25.61% 74.39% 24.13% 41.35% 8.91%
422 28.87% 71.13% 22.97% 39.69% 8.48% 488 25.57% 74.43% 24.15% 41.37% 8.91%
423 28.82% 71.18% 22.98% 39.71% 8.49% 489 25.51% 74.49% 24.17% 41.40% 8.92%
424 28.76% 71.24% 23.01% 39.75% 8.49% 490 25.47% 74.53% 24.18% 41.42% 8.92%
425 28.71% 71.29% 23.02% 39.77% 8.50% 491 25.42% 74.58% 24.20% 41.45% 8.93%
426 28.67% 71.33% 23.04% 39.79% 8.51% 492 25.37% 74.63% 24.21% 41.48% 8.94%
427 28.62% 71.39% 23.06% 39.82% 8.51% 493 25.32% 74.68% 24.23% 41.51% 8.94%
428 28.56% 71.44% 23.07% 39.85% 8.52% 494 25.28% 74.72% 24.24% 41.53% 8.95%
429 28.50% 71.50% 23.09% 39.88% 8.53% 495 25.23% 74.77% 24.26% 41.57% 8.95%
430 28.44% 71.56% 23.12% 39.90% 8.54% 496 25.19% 74.81% 24.27% 41.59% 8.96%
431 28.39% 71.61% 23.14% 39.93% 8.54% 497 25.13% 74.87% 24.29% 41.61% 8.97%
432 28.33% 71.67% 23.15% 39.96% 8.55% 498 25.09% 74.91% 24.30% 41.63% 8.97%
433 28.29% 71.71% 23.17% 39.98% 8.56% 499 25.03% 74.97% 24.32% 41.66% 8.98%
434 28.25% 71.75% 23.18% 40.01% 8.56% 500 24.98% 75.02% 24.34% 41.69% 8.99%
435 28.19% 71.81% 23.20% 40.04% 8.57% 501 24.94% 75.06% 24.36% 41.71% 8.99%
436 28.14% 71.86% 23.22% 40.06% 8.58% 502 24.89% 75.11% 24.39% 41.73% 9.00%
437 28.08% 71.92% 23.24% 40.09% 8.58% 503 24.84% 75.16% 24.40% 41.75% 9.01%
438 28.03% 71.97% 23.26% 40.12% 8.59% 504 24.79% 75.21% 24.41% 41.79% 9.01%
439 27.97% 72.03% 23.28% 40.14% 8.60% 505 24.75% 75.25% 24.43% 41.80% 9.02%
440 27.92% 72.08% 23.29% 40.18% 8.61% 506 24.72% 75.28% 24.45% 41.82% 9.02%
441 27.87% 72.13% 23.31% 40.21% 8.62% 507 24.68% 75.32% 24.46% 41.84% 9.03%
442 27.81% 72.19% 23.34% 40.23% 8.62% 508 24.63% 75.37% 24.47% 41.87% 9.03%
443 27.76% 72.24% 23.36% 40.25% 8.63% 509 24.58% 75.42% 24.49% 41.89% 9.04%
444 27.71% 72.30% 23.38% 40.28% 8.64% 510 24.53% 75.47% 24.51% 41.92% 9.04%
445 27.66% 72.34% 23.40% 40.30% 8.64% 511 24.49% 75.51% 24.51% 41.95% 9.05%
446 27.61% 72.39% 23.43% 40.32% 8.65% 512 24.45% 75.55% 24.53% 41.97% 9.05%
447 27.56% 72.44% 23.45% 40.34% 8.66% 513 24.40% 75.60% 24.54% 42.00% 9.06%
448 27.52% 72.48% 23.46% 40.35% 8.66% 514 24.36% 75.64% 24.55% 42.03% 9.06%
449 27.47% 72.53% 23.48% 40.38% 8.67% 515 24.32% 75.68% 24.57% 42.05% 9.07%
450 27.42% 72.58% 23.50% 40.41% 8.68% 516 24.27% 75.73% 24.59% 42.07% 9.07%
451 27.37% 72.63% 23.52% 40.43% 8.69% 517 24.22% 75.78% 24.61% 42.10% 9.08%
452 27.32% 72.68% 23.54% 40.45% 8.69% 518 24.18% 75.82% 24.62% 42.12% 9.08%
453 27.26% 72.74% 23.56% 40.48% 8.70% 519 24.14% 75.87% 24.63% 42.15% 9.09%
454 27.21% 72.79% 23.57% 40.51% 8.70% 520 24.10% 75.90% 24.65% 42.16% 9.09%
455 27.15% 72.85% 23.60% 40.54% 8.72% 521 24.05% 75.95% 24.67% 42.18% 9.10%
456 27.10% 72.90% 23.61% 40.56% 8.72% 522 24.01% 75.99% 24.68% 42.21% 9.10%
457 27.07% 72.93% 23.63% 40.59% 8.72% 523 23.97% 76.03% 24.70% 42.23% 9.11%
458 27.03% 72.97% 23.63% 40.61% 8.73% 524 23.94% 76.07% 24.71% 42.25% 9.11%
459 26.99% 73.01% 23.65% 40.62% 8.73% 525 23.89% 76.11% 24.72% 42.28% 9.12%
460 26.93% 73.07% 23.67% 40.67% 8.73% 526 23.85% 76.15% 24.73% 42.29% 9.12%
461 26.88% 73.12% 23.69% 40.69% 8.74% 527 23.81% 76.19% 24.75% 42.31% 9.13%
462 26.83% 73.17% 23.71% 40.71% 8.76% 528 23.77% 76.23% 24.77% 42.33% 9.13%
463 26.78% 73.23% 23.73% 40.73% 8.76% 529 23.73% 76.27% 24.78% 42.35% 9.14%
464 26.72% 73.28% 23.75% 40.76% 8.77% 530 23.68% 76.32% 24.80% 42.38% 9.14%
465 26.67% 73.33% 23.77% 40.79% 8.78% 531 23.65% 76.35% 24.81% 42.40% 9.15%
466 26.62% 73.39% 23.79% 40.82% 8.78% 532 23.61% 76.39% 24.82% 42.42% 9.15%
467 26.57% 73.43% 23.80% 40.85% 8.79% 533 23.58% 76.42% 24.83% 42.44% 9.15%
468 26.51% 73.49% 23.82% 40.87% 8.79% 534 23.55% 76.46% 24.84% 42.45% 9.16%
469 26.47% 73.53% 23.83% 40.90% 8.80% 535 23.50% 76.50% 24.86% 42.48% 9.17%
470 26.42% 73.58% 23.85% 40.92% 8.81% 536 23.46% 76.54% 24.87% 42.50% 9.17%
471 26.37% 73.63% 23.87% 40.94% 8.82% 537 23.42% 76.58% 24.88% 42.52% 9.17%
472 26.31% 73.69% 23.88% 40.98% 8.82% 538 23.38% 76.62% 24.90% 42.54% 9.18%
473 26.28% 73.73% 23.90% 41.00% 8.83% 539 23.35% 76.65% 24.92% 42.56% 9.18%
474 26.23% 73.77% 23.91% 41.03% 8.83% 540 23.30% 76.70% 24.94% 42.58% 9.18%
475 26.18% 73.82% 23.92% 41.05% 8.84% 541 23.26% 76.75% 24.96% 42.60% 9.19%
476 26.15% 73.85% 23.94% 41.07% 8.84% 542 23.22% 76.78% 24.97% 42.62% 9.19%
477 26.10% 73.90% 23.96% 41.09% 8.85% 543 23.19% 76.82% 24.98% 42.64% 9.19%
478 26.05% 73.96% 23.97% 41.12% 8.86% 544 23.15% 76.85% 25.00% 42.65% 9.20%
479 26.01% 73.99% 23.98% 41.14% 8.86% 545 23.11% 76.89% 25.01% 42.67% 9.21%
480 25.97% 74.03% 24.00% 41.16% 8.87% 546 23.07% 76.93% 25.03% 42.69% 9.21%
481 25.91% 74.09% 24.02% 41.20% 8.87% 547 23.03% 76.97% 25.04% 42.72% 9.22%
482 25.86% 74.14% 24.04% 41.22% 8.88% 548 22.99% 77.01% 25.06% 42.74% 9.22%
483 25.81% 74.19% 24.05% 41.25% 8.88% 549 22.95% 77.06% 25.07% 42.76% 9.22%
484 25.77% 74.23% 24.07% 41.27% 8.89% 550 22.91% 77.09% 25.09% 42.78% 9.23%
485 25.72% 74.28% 24.09% 41.30% 8.89% 551 22.87% 77.13% 25.10% 42.80% 9.24%
251
552 22.83% 77.17% 25.11% 42.82% 9.24% 618 20.45% 79.55% 25.96% 44.05% 9.54%
553 22.79% 77.21% 25.12% 42.84% 9.25% 619 20.42% 79.58% 25.97% 44.07% 9.54%
554 22.76% 77.24% 25.13% 42.86% 9.25% 620 20.39% 79.61% 25.98% 44.08% 9.55%
555 22.72% 77.28% 25.14% 42.88% 9.25% 621 20.35% 79.66% 26.00% 44.11% 9.55%
556 22.69% 77.32% 25.15% 42.90% 9.26% 622 20.31% 79.69% 26.01% 44.12% 9.56%
557 22.65% 77.35% 25.17% 42.92% 9.27% 623 20.27% 79.73% 26.02% 44.14% 9.56%
558 22.61% 77.39% 25.18% 42.94% 9.27% 624 20.24% 79.76% 26.04% 44.16% 9.57%
559 22.58% 77.42% 25.19% 42.96% 9.27% 625 20.20% 79.80% 26.05% 44.18% 9.57%
560 22.54% 77.46% 25.20% 42.98% 9.27% 626 20.17% 79.83% 26.06% 44.19% 9.58%
561 22.50% 77.50% 25.22% 43.00% 9.28% 627 20.15% 79.85% 26.06% 44.21% 9.58%
562 22.45% 77.55% 25.24% 43.03% 9.28% 628 20.11% 79.89% 26.08% 44.23% 9.58%
563 22.41% 77.59% 25.25% 43.05% 9.28% 629 20.09% 79.91% 26.09% 44.24% 9.58%
564 22.38% 77.63% 25.27% 43.06% 9.29% 630 20.06% 79.94% 26.10% 44.25% 9.59%
565 22.34% 77.66% 25.28% 43.08% 9.30% 631 20.03% 79.97% 26.11% 44.27% 9.59%
566 22.31% 77.69% 25.29% 43.09% 9.30% 632 19.99% 80.01% 26.13% 44.28% 9.60%
567 22.27% 77.73% 25.31% 43.11% 9.31% 633 19.97% 80.03% 26.14% 44.29% 9.60%
568 22.23% 77.77% 25.33% 43.12% 9.32% 634 19.94% 80.06% 26.15% 44.31% 9.60%
569 22.19% 77.81% 25.35% 43.14% 9.32% 635 19.91% 80.09% 26.16% 44.33% 9.60%
570 22.15% 77.85% 25.36% 43.16% 9.32% 636 19.87% 80.13% 26.18% 44.34% 9.61%
571 22.12% 77.88% 25.37% 43.18% 9.33% 637 19.84% 80.16% 26.19% 44.36% 9.61%
572 22.08% 77.92% 25.39% 43.20% 9.33% 638 19.82% 80.19% 26.19% 44.38% 9.62%
573 22.04% 77.96% 25.40% 43.23% 9.33% 639 19.79% 80.21% 26.21% 44.39% 9.62%
574 22.00% 78.00% 25.42% 43.24% 9.34% 640 19.76% 80.24% 26.22% 44.40% 9.62%
575 21.97% 78.03% 25.42% 43.26% 9.34% 641 19.73% 80.27% 26.23% 44.42% 9.63%
576 21.95% 78.06% 25.43% 43.28% 9.35% 642 19.70% 80.30% 26.24% 44.44% 9.63%
577 21.90% 78.10% 25.45% 43.30% 9.35% 643 19.66% 80.34% 26.25% 44.46% 9.63%
578 21.86% 78.14% 25.47% 43.32% 9.36% 644 19.63% 80.37% 26.26% 44.48% 9.64%
579 21.82% 78.18% 25.48% 43.33% 9.36% 645 19.60% 80.41% 26.27% 44.49% 9.64%
580 21.78% 78.22% 25.50% 43.35% 9.37% 646 19.56% 80.44% 26.28% 44.51% 9.64%
581 21.75% 78.25% 25.51% 43.37% 9.38% 647 19.54% 80.46% 26.29% 44.53% 9.65%
582 21.71% 78.29% 25.52% 43.39% 9.38% 648 19.51% 80.49% 26.29% 44.54% 9.66%
583 21.68% 78.32% 25.53% 43.41% 9.38% 649 19.48% 80.52% 26.30% 44.56% 9.66%
584 21.64% 78.36% 25.54% 43.43% 9.39% 650 19.44% 80.56% 26.32% 44.58% 9.66%
585 21.61% 78.39% 25.55% 43.45% 9.39% 651 19.42% 80.58% 26.32% 44.59% 9.67%
586 21.57% 78.43% 25.57% 43.46% 9.40% 652 19.39% 80.61% 26.33% 44.61% 9.67%
587 21.55% 78.45% 25.57% 43.47% 9.41% 653 19.36% 80.64% 26.34% 44.63% 9.67%
588 21.51% 78.49% 25.59% 43.50% 9.41% 654 19.34% 80.66% 26.35% 44.64% 9.67%
589 21.47% 78.53% 25.60% 43.51% 9.41% 655 19.31% 80.69% 26.36% 44.65% 9.68%
590 21.43% 78.57% 25.61% 43.54% 9.42% 656 19.29% 80.71% 26.37% 44.66% 9.68%
591 21.40% 78.60% 25.63% 43.55% 9.42% 657 19.26% 80.74% 26.38% 44.68% 9.68%
592 21.36% 78.64% 25.64% 43.57% 9.43% 658 19.23% 80.77% 26.40% 44.69% 9.68%
593 21.33% 78.67% 25.65% 43.59% 9.43% 659 19.20% 80.80% 26.41% 44.71% 9.69%
594 21.29% 78.71% 25.66% 43.62% 9.44% 660 19.15% 80.85% 26.42% 44.73% 9.69%
595 21.24% 78.76% 25.68% 43.63% 9.45% 661 19.12% 80.88% 26.44% 44.75% 9.70%
596 21.22% 78.78% 25.69% 43.65% 9.45% 662 19.09% 80.91% 26.44% 44.76% 9.70%
597 21.18% 78.82% 25.70% 43.67% 9.46% 663 19.08% 80.93% 26.45% 44.77% 9.70%
598 21.16% 78.84% 25.71% 43.67% 9.46% 664 19.04% 80.96% 26.46% 44.79% 9.71%
599 21.13% 78.87% 25.72% 43.69% 9.46% 665 19.02% 80.98% 26.46% 44.81% 9.71%
600 21.09% 78.91% 25.73% 43.72% 9.46% 666 18.99% 81.02% 26.47% 44.83% 9.72%
601 21.06% 78.94% 25.74% 43.73% 9.47% 667 18.95% 81.05% 26.49% 44.84% 9.72%
602 21.02% 78.98% 25.76% 43.75% 9.47% 668 18.92% 81.08% 26.50% 44.85% 9.73%
603 20.99% 79.01% 25.77% 43.76% 9.48% 669 18.88% 81.12% 26.51% 44.88% 9.73%
604 20.96% 79.04% 25.78% 43.78% 9.48% 670 18.85% 81.15% 26.52% 44.89% 9.73%
605 20.92% 79.08% 25.79% 43.80% 9.48% 671 18.82% 81.18% 26.53% 44.91% 9.74%
606 20.88% 79.12% 25.80% 43.82% 9.49% 672 18.79% 81.21% 26.55% 44.92% 9.75%
607 20.85% 79.15% 25.82% 43.83% 9.49% 673 18.76% 81.24% 26.56% 44.93% 9.75%
608 20.81% 79.19% 25.83% 43.86% 9.50% 674 18.73% 81.27% 26.57% 44.95% 9.75%
609 20.77% 79.23% 25.85% 43.88% 9.50% 675 18.71% 81.29% 26.58% 44.96% 9.75%
610 20.74% 79.26% 25.86% 43.89% 9.51% 676 18.68% 81.32% 26.59% 44.98% 9.76%
611 20.70% 79.30% 25.88% 43.90% 9.52% 677 18.64% 81.36% 26.60% 44.99% 9.76%
612 20.67% 79.33% 25.89% 43.92% 9.52% 678 18.62% 81.38% 26.61% 45.01% 9.77%
613 20.64% 79.36% 25.90% 43.93% 9.53% 679 18.59% 81.41% 26.62% 45.02% 9.77%
614 20.61% 79.39% 25.91% 43.95% 9.53% 680 18.57% 81.43% 26.63% 45.03% 9.78%
615 20.57% 79.43% 25.92% 43.97% 9.54% 681 18.54% 81.46% 26.64% 45.05% 9.78%
616 20.52% 79.48% 25.94% 44.00% 9.54% 682 18.51% 81.49% 26.64% 45.06% 9.78%
617 20.49% 79.51% 25.95% 44.02% 9.54% 683 18.48% 81.52% 26.66% 45.08% 9.78%
252
684 18.45% 81.55% 26.66% 45.10% 9.79% 750 16.80% 83.21% 27.28% 45.97% 9.96%
685 18.42% 81.58% 26.68% 45.12% 9.79% 751 16.77% 83.23% 27.28% 45.99% 9.96%
686 18.39% 81.61% 26.69% 45.13% 9.79% 752 16.74% 83.26% 27.29% 46.00% 9.97%
687 18.37% 81.63% 26.69% 45.15% 9.80% 753 16.71% 83.29% 27.30% 46.02% 9.97%
688 18.34% 81.66% 26.70% 45.16% 9.80% 754 16.69% 83.31% 27.31% 46.03% 9.98%
689 18.32% 81.68% 26.71% 45.17% 9.80% 755 16.66% 83.34% 27.31% 46.05% 9.98%
690 18.29% 81.71% 26.71% 45.19% 9.81% 756 16.63% 83.38% 27.33% 46.07% 9.98%
691 18.26% 81.74% 26.73% 45.21% 9.81% 757 16.59% 83.41% 27.34% 46.08% 9.98%
692 18.23% 81.77% 26.74% 45.22% 9.81% 758 16.57% 83.43% 27.35% 46.10% 9.99%
693 18.20% 81.80% 26.75% 45.24% 9.82% 759 16.55% 83.45% 27.36% 46.10% 9.99%
694 18.18% 81.82% 26.75% 45.25% 9.82% 760 16.52% 83.48% 27.37% 46.12% 9.99%
695 18.16% 81.84% 26.77% 45.26% 9.82% 761 16.50% 83.51% 27.38% 46.13% 10.00%
696 18.14% 81.86% 26.78% 45.27% 9.82% 762 16.47% 83.53% 27.39% 46.15% 10.00%
697 18.11% 81.89% 26.79% 45.28% 9.82% 763 16.44% 83.56% 27.40% 46.16% 10.00%
698 18.10% 81.90% 26.79% 45.29% 9.83% 764 16.43% 83.57% 27.40% 46.17% 10.00%
699 18.06% 81.94% 26.81% 45.30% 9.83% 765 16.40% 83.60% 27.41% 46.19% 10.00%
700 18.04% 81.96% 26.82% 45.31% 9.83% 766 16.37% 83.63% 27.43% 46.20% 10.00%
701 18.01% 81.99% 26.83% 45.33% 9.83% 767 16.35% 83.65% 27.44% 46.21% 10.01%
702 17.98% 82.02% 26.84% 45.34% 9.84% 768 16.33% 83.67% 27.44% 46.22% 10.01%
703 17.96% 82.04% 26.85% 45.35% 9.84% 769 16.30% 83.70% 27.45% 46.23% 10.01%
704 17.95% 82.05% 26.85% 45.36% 9.84% 770 16.28% 83.72% 27.47% 46.24% 10.01%
705 17.93% 82.07% 26.86% 45.37% 9.85% 771 16.25% 83.75% 27.48% 46.26% 10.01%
706 17.90% 82.10% 26.87% 45.39% 9.85% 772 16.23% 83.77% 27.49% 46.27% 10.02%
707 17.87% 82.13% 26.88% 45.40% 9.85% 773 16.21% 83.79% 27.49% 46.28% 10.02%
708 17.85% 82.15% 26.88% 45.41% 9.85% 774 16.18% 83.82% 27.50% 46.29% 10.03%
709 17.83% 82.17% 26.89% 45.43% 9.86% 775 16.16% 83.84% 27.51% 46.30% 10.03%
710 17.81% 82.19% 26.89% 45.44% 9.86% 776 16.13% 83.87% 27.53% 46.31% 10.03%
711 17.78% 82.22% 26.90% 45.46% 9.86% 777 16.12% 83.88% 27.53% 46.32% 10.03%
712 17.75% 82.25% 26.91% 45.48% 9.86% 778 16.09% 83.91% 27.54% 46.34% 10.04%
713 17.73% 82.28% 26.92% 45.49% 9.87% 779 16.07% 83.93% 27.55% 46.34% 10.04%
714 17.70% 82.30% 26.94% 45.50% 9.87% 780 16.05% 83.95% 27.56% 46.35% 10.04%
715 17.67% 82.33% 26.95% 45.51% 9.87% 781 16.03% 83.97% 27.56% 46.36% 10.04%
716 17.65% 82.35% 26.96% 45.52% 9.87% 782 16.02% 83.99% 27.57% 46.37% 10.05%
717 17.63% 82.38% 26.96% 45.54% 9.87% 783 16.00% 84.00% 27.58% 46.38% 10.05%
718 17.61% 82.39% 26.97% 45.55% 9.88% 784 15.97% 84.03% 27.59% 46.39% 10.05%
719 17.58% 82.42% 26.98% 45.57% 9.88% 785 15.95% 84.05% 27.60% 46.40% 10.05%
720 17.55% 82.45% 26.99% 45.58% 9.88% 786 15.93% 84.08% 27.61% 46.41% 10.06%
721 17.52% 82.48% 27.01% 45.60% 9.88% 787 15.90% 84.10% 27.61% 46.43% 10.06%
722 17.50% 82.50% 27.01% 45.61% 9.88% 788 15.88% 84.12% 27.62% 46.44% 10.06%
723 17.48% 82.53% 27.02% 45.62% 9.89% 789 15.86% 84.15% 27.63% 46.45% 10.07%
724 17.45% 82.55% 27.03% 45.63% 9.89% 790 15.83% 84.17% 27.64% 46.47% 10.07%
725 17.42% 82.59% 27.04% 45.65% 9.89% 791 15.81% 84.19% 27.65% 46.48% 10.07%
726 17.39% 82.61% 27.05% 45.66% 9.90% 792 15.79% 84.21% 27.65% 46.49% 10.07%
727 17.37% 82.63% 27.06% 45.68% 9.90% 793 15.77% 84.24% 27.66% 46.50% 10.08%
728 17.35% 82.65% 27.06% 45.69% 9.90% 794 15.75% 84.25% 27.67% 46.51% 10.08%
729 17.33% 82.67% 27.07% 45.70% 9.90% 795 15.72% 84.28% 27.67% 46.53% 10.08%
730 17.30% 82.70% 27.08% 45.71% 9.91% 796 15.70% 84.30% 27.68% 46.54% 10.09%
731 17.28% 82.72% 27.09% 45.73% 9.91% 797 15.68% 84.32% 27.68% 46.55% 10.09%
732 17.26% 82.74% 27.09% 45.74% 9.91% 798 15.67% 84.33% 27.69% 46.56% 10.09%
733 17.24% 82.76% 27.10% 45.75% 9.91% 799 15.65% 84.35% 27.69% 46.57% 10.09%
734 17.21% 82.79% 27.11% 45.76% 9.92% 800 15.63% 84.37% 27.70% 46.58% 10.09%
735 17.19% 82.81% 27.13% 45.77% 9.92% 801 15.61% 84.39% 27.71% 46.59% 10.10%
736 17.17% 82.83% 27.13% 45.78% 9.92% 802 15.60% 84.41% 27.71% 46.59% 10.10%
737 17.14% 82.86% 27.14% 45.80% 9.93% 803 15.57% 84.43% 27.72% 46.61% 10.10%
738 17.11% 82.89% 27.15% 45.81% 9.93% 804 15.54% 84.46% 27.73% 46.62% 10.11%
739 17.08% 82.92% 27.16% 45.82% 9.94% 805 15.52% 84.48% 27.74% 46.63% 10.11%
740 17.05% 82.95% 27.17% 45.84% 9.94% 806 15.49% 84.51% 27.75% 46.64% 10.11%
741 17.02% 82.98% 27.18% 45.85% 9.94% 807 15.47% 84.53% 27.76% 46.66% 10.12%
742 16.99% 83.01% 27.19% 45.87% 9.95% 808 15.44% 84.56% 27.77% 46.68% 10.12%
743 16.97% 83.03% 27.20% 45.88% 9.95% 809 15.41% 84.59% 27.77% 46.69% 10.12%
744 16.95% 83.05% 27.21% 45.89% 9.95% 810 15.39% 84.62% 27.79% 46.70% 10.13%
745 16.92% 83.08% 27.22% 45.91% 9.95% 811 15.36% 84.64% 27.80% 46.71% 10.13%
746 16.89% 83.11% 27.23% 45.93% 9.95% 812 15.34% 84.66% 27.81% 46.72% 10.13%
747 16.87% 83.14% 27.24% 45.94% 9.95% 813 15.31% 84.69% 27.82% 46.73% 10.14%
748 16.85% 83.16% 27.25% 45.95% 9.96% 814 15.30% 84.71% 27.82% 46.74% 10.14%
749 16.82% 83.18% 27.26% 45.96% 9.96% 815 15.27% 84.73% 27.83% 46.76% 10.14%
253
816 15.26% 84.74% 27.84% 46.77% 10.14% 882 13.97% 86.03% 28.31% 47.43% 10.28%
817 15.24% 84.76% 27.84% 46.77% 10.14% 883 13.96% 86.04% 28.32% 47.44% 10.28%
818 15.22% 84.78% 27.85% 46.79% 10.15% 884 13.93% 86.07% 28.33% 47.45% 10.29%
819 15.20% 84.80% 27.86% 46.80% 10.15% 885 13.91% 86.09% 28.34% 47.46% 10.29%
820 15.18% 84.82% 27.86% 46.81% 10.15% 886 13.90% 86.10% 28.34% 47.46% 10.29%
821 15.17% 84.84% 27.87% 46.81% 10.15% 887 13.88% 86.12% 28.35% 47.47% 10.29%
822 15.14% 84.86% 27.88% 46.83% 10.15% 888 13.87% 86.13% 28.36% 47.48% 10.29%
823 15.13% 84.87% 27.89% 46.83% 10.15% 889 13.85% 86.15% 28.36% 47.49% 10.29%
824 15.11% 84.89% 27.89% 46.84% 10.16% 890 13.84% 86.16% 28.37% 47.50% 10.29%
825 15.08% 84.92% 27.90% 46.86% 10.16% 891 13.82% 86.18% 28.38% 47.51% 10.29%
826 15.06% 84.94% 27.91% 46.87% 10.16% 892 13.81% 86.19% 28.38% 47.51% 10.30%
827 15.03% 84.97% 27.92% 46.88% 10.17% 893 13.79% 86.21% 28.39% 47.52% 10.30%
828 15.01% 84.99% 27.93% 46.89% 10.17% 894 13.78% 86.23% 28.40% 47.52% 10.30%
829 15.00% 85.00% 27.94% 46.89% 10.17% 895 13.77% 86.23% 28.40% 47.53% 10.30%
830 14.98% 85.03% 27.95% 46.90% 10.18% 896 13.75% 86.25% 28.41% 47.53% 10.31%
831 14.95% 85.05% 27.96% 46.92% 10.18% 897 13.74% 86.26% 28.42% 47.54% 10.31%
832 14.94% 85.06% 27.96% 46.92% 10.18% 898 13.73% 86.28% 28.42% 47.55% 10.31%
833 14.92% 85.08% 27.97% 46.93% 10.18% 899 13.71% 86.29% 28.43% 47.56% 10.31%
834 14.90% 85.10% 27.97% 46.95% 10.18% 900 13.68% 86.32% 28.44% 47.56% 10.32%
835 14.88% 85.12% 27.98% 46.96% 10.18% 901 13.66% 86.34% 28.45% 47.57% 10.32%
836 14.85% 85.15% 27.99% 46.97% 10.18% 902 13.64% 86.36% 28.46% 47.58% 10.32%
837 14.83% 85.17% 28.00% 46.98% 10.18% 903 13.62% 86.38% 28.46% 47.60% 10.32%
838 14.81% 85.19% 28.01% 47.00% 10.18% 904 13.61% 86.39% 28.47% 47.60% 10.32%
839 14.79% 85.21% 28.01% 47.01% 10.19% 905 13.59% 86.41% 28.47% 47.62% 10.33%
840 14.77% 85.24% 28.02% 47.02% 10.19% 906 13.57% 86.43% 28.48% 47.62% 10.33%
841 14.74% 85.26% 28.03% 47.04% 10.19% 907 13.55% 86.45% 28.49% 47.63% 10.33%
842 14.73% 85.27% 28.03% 47.04% 10.19% 908 13.53% 86.47% 28.50% 47.64% 10.33%
843 14.71% 85.29% 28.04% 47.06% 10.20% 909 13.51% 86.49% 28.51% 47.65% 10.34%
844 14.68% 85.32% 28.04% 47.07% 10.20% 910 13.49% 86.51% 28.52% 47.65% 10.34%
845 14.67% 85.33% 28.05% 47.08% 10.20% 911 13.48% 86.52% 28.52% 47.66% 10.34%
846 14.64% 85.36% 28.06% 47.10% 10.20% 912 13.47% 86.53% 28.53% 47.66% 10.34%
847 14.63% 85.37% 28.07% 47.10% 10.21% 913 13.45% 86.55% 28.53% 47.67% 10.35%
848 14.61% 85.39% 28.07% 47.11% 10.21% 914 13.43% 86.57% 28.54% 47.68% 10.35%
849 14.59% 85.41% 28.08% 47.12% 10.21% 915 13.42% 86.58% 28.54% 47.68% 10.36%
850 14.58% 85.42% 28.09% 47.13% 10.21% 916 13.40% 86.60% 28.55% 47.69% 10.36%
851 14.56% 85.44% 28.09% 47.14% 10.21% 917 13.39% 86.61% 28.55% 47.70% 10.36%
852 14.54% 85.46% 28.10% 47.15% 10.21% 918 13.37% 86.63% 28.56% 47.71% 10.36%
853 14.53% 85.47% 28.10% 47.15% 10.21% 919 13.36% 86.64% 28.56% 47.72% 10.36%
854 14.52% 85.48% 28.11% 47.16% 10.22% 920 13.34% 86.66% 28.57% 47.73% 10.36%
855 14.50% 85.50% 28.12% 47.17% 10.22% 921 13.33% 86.67% 28.57% 47.73% 10.36%
856 14.48% 85.52% 28.12% 47.18% 10.22% 922 13.31% 86.69% 28.58% 47.74% 10.36%
857 14.46% 85.54% 28.13% 47.19% 10.22% 923 13.30% 86.70% 28.59% 47.75% 10.37%
858 14.44% 85.56% 28.13% 47.20% 10.22% 924 13.28% 86.73% 28.59% 47.77% 10.37%
859 14.43% 85.57% 28.14% 47.21% 10.22% 925 13.26% 86.74% 28.60% 47.77% 10.37%
860 14.40% 85.60% 28.15% 47.22% 10.23% 926 13.24% 86.76% 28.61% 47.78% 10.37%
861 14.39% 85.62% 28.15% 47.23% 10.23% 927 13.23% 86.77% 28.61% 47.79% 10.37%
862 14.36% 85.64% 28.17% 47.24% 10.23% 928 13.22% 86.79% 28.61% 47.80% 10.38%
863 14.34% 85.66% 28.17% 47.25% 10.24% 929 13.20% 86.80% 28.61% 47.81% 10.38%
864 14.32% 85.68% 28.18% 47.26% 10.24% 930 13.19% 86.81% 28.61% 47.82% 10.38%
865 14.30% 85.70% 28.19% 47.27% 10.24% 931 13.18% 86.82% 28.62% 47.83% 10.38%
866 14.29% 85.71% 28.20% 47.27% 10.24% 932 13.16% 86.84% 28.62% 47.84% 10.38%
867 14.26% 85.74% 28.21% 47.29% 10.24% 933 13.14% 86.86% 28.62% 47.85% 10.39%
868 14.24% 85.76% 28.22% 47.29% 10.24% 934 13.12% 86.88% 28.63% 47.86% 10.39%
869 14.23% 85.77% 28.22% 47.30% 10.24% 935 13.10% 86.90% 28.63% 47.87% 10.40%
870 14.21% 85.79% 28.24% 47.31% 10.25% 936 13.09% 86.91% 28.64% 47.88% 10.40%
871 14.19% 85.81% 28.24% 47.32% 10.25% 937 13.07% 86.93% 28.64% 47.88% 10.40%
872 14.16% 85.84% 28.25% 47.33% 10.25% 938 13.06% 86.94% 28.65% 47.89% 10.40%
873 14.14% 85.86% 28.26% 47.34% 10.26% 939 13.05% 86.95% 28.65% 47.89% 10.41%
874 14.12% 85.88% 28.26% 47.36% 10.26% 940 13.03% 86.97% 28.66% 47.91% 10.41%
875 14.10% 85.90% 28.27% 47.37% 10.27% 941 13.01% 86.99% 28.66% 47.92% 10.41%
876 14.08% 85.92% 28.28% 47.38% 10.27% 942 12.99% 87.01% 28.67% 47.93% 10.41%
877 14.06% 85.94% 28.28% 47.39% 10.27% 943 12.97% 87.03% 28.68% 47.94% 10.41%
878 14.04% 85.96% 28.29% 47.40% 10.27% 944 12.95% 87.05% 28.69% 47.95% 10.42%
879 14.03% 85.97% 28.30% 47.41% 10.27% 945 12.94% 87.06% 28.69% 47.95% 10.42%
880 14.01% 85.99% 28.30% 47.41% 10.28% 946 12.92% 87.08% 28.70% 47.96% 10.42%
881 13.99% 86.01% 28.31% 47.43% 10.28% 947 12.90% 87.10% 28.71% 47.97% 10.42%
254
948 12.88% 87.12% 28.72% 47.98% 10.42% 1014 11.94% 88.06% 29.06% 48.48% 10.53%
949 12.87% 87.13% 28.72% 47.99% 10.42% 1015 11.92% 88.08% 29.06% 48.49% 10.53%
950 12.84% 87.16% 28.73% 48.00% 10.43% 1016 11.91% 88.09% 29.07% 48.49% 10.54%
951 12.83% 87.17% 28.73% 48.01% 10.43% 1017 11.89% 88.11% 29.08% 48.50% 10.54%
952 12.82% 87.18% 28.74% 48.01% 10.43% 1018 11.88% 88.12% 29.08% 48.50% 10.54%
953 12.80% 87.20% 28.75% 48.02% 10.43% 1019 11.87% 88.13% 29.09% 48.51% 10.54%
954 12.78% 87.22% 28.76% 48.03% 10.43% 1020 11.86% 88.14% 29.09% 48.51% 10.54%
955 12.77% 87.23% 28.76% 48.04% 10.43% 1021 11.85% 88.16% 29.09% 48.52% 10.54%
956 12.75% 87.25% 28.77% 48.04% 10.43% 1022 11.84% 88.16% 29.10% 48.52% 10.54%
957 12.74% 87.27% 28.78% 48.05% 10.44% 1023 11.83% 88.17% 29.10% 48.53% 10.55%
958 12.72% 87.28% 28.78% 48.06% 10.44% 1024 11.81% 88.20% 29.11% 48.54% 10.55%
959 12.71% 87.29% 28.78% 48.07% 10.44% 1025 11.79% 88.21% 29.11% 48.55% 10.55%
960 12.70% 87.30% 28.79% 48.07% 10.44% 1026 11.78% 88.22% 29.11% 48.56% 10.55%
961 12.68% 87.32% 28.80% 48.08% 10.44% 1027 11.77% 88.23% 29.12% 48.56% 10.55%
962 12.67% 87.33% 28.80% 48.08% 10.45% 1028 11.76% 88.24% 29.12% 48.57% 10.55%
963 12.65% 87.35% 28.81% 48.10% 10.45% 1029 11.75% 88.25% 29.13% 48.57% 10.55%
964 12.63% 87.37% 28.81% 48.10% 10.46% 1030 11.74% 88.26% 29.13% 48.58% 10.56%
965 12.62% 87.38% 28.82% 48.11% 10.46% 1031 11.72% 88.28% 29.14% 48.58% 10.56%
966 12.61% 87.39% 28.82% 48.12% 10.46% 1032 11.71% 88.29% 29.15% 48.59% 10.56%
967 12.59% 87.41% 28.83% 48.13% 10.46% 1033 11.70% 88.30% 29.15% 48.60% 10.56%
968 12.57% 87.43% 28.83% 48.13% 10.46% 1034 11.69% 88.31% 29.15% 48.60% 10.56%
969 12.57% 87.44% 28.84% 48.14% 10.46% 1035 11.68% 88.33% 29.15% 48.61% 10.56%
970 12.55% 87.45% 28.84% 48.14% 10.47% 1036 11.66% 88.34% 29.16% 48.62% 10.56%
971 12.54% 87.46% 28.84% 48.15% 10.47% 1037 11.64% 88.36% 29.17% 48.63% 10.57%
972 12.53% 87.47% 28.85% 48.16% 10.47% 1038 11.64% 88.36% 29.17% 48.63% 10.57%
973 12.52% 87.48% 28.85% 48.17% 10.47% 1039 11.62% 88.38% 29.18% 48.64% 10.57%
974 12.50% 87.50% 28.86% 48.18% 10.47% 1040 11.62% 88.39% 29.18% 48.64% 10.57%
975 12.48% 87.52% 28.86% 48.18% 10.48% 1041 11.60% 88.40% 29.18% 48.65% 10.57%
976 12.47% 87.54% 28.87% 48.19% 10.48% 1042 11.59% 88.41% 29.19% 48.66% 10.57%
977 12.45% 87.55% 28.87% 48.20% 10.48% 1043 11.58% 88.42% 29.19% 48.66% 10.57%
978 12.44% 87.56% 28.87% 48.21% 10.48% 1044 11.57% 88.43% 29.19% 48.67% 10.57%
979 12.42% 87.58% 28.88% 48.22% 10.48% 1045 11.57% 88.43% 29.20% 48.67% 10.57%
980 12.41% 87.59% 28.88% 48.23% 10.48% 1046 11.56% 88.44% 29.20% 48.67% 10.57%
981 12.40% 87.60% 28.89% 48.23% 10.49% 1047 11.55% 88.45% 29.21% 48.68% 10.57%
982 12.38% 87.62% 28.89% 48.24% 10.49% 1048 11.54% 88.46% 29.21% 48.68% 10.57%
983 12.36% 87.64% 28.90% 48.25% 10.49% 1049 11.53% 88.47% 29.21% 48.69% 10.57%
984 12.35% 87.65% 28.90% 48.26% 10.49% 1050 11.51% 88.49% 29.22% 48.70% 10.57%
985 12.33% 87.67% 28.91% 48.27% 10.49% 1051 11.51% 88.50% 29.22% 48.70% 10.58%
986 12.32% 87.69% 28.91% 48.28% 10.49% 1052 11.48% 88.52% 29.23% 48.71% 10.58%
987 12.30% 87.70% 28.92% 48.29% 10.50% 1053 11.47% 88.53% 29.23% 48.72% 10.58%
988 12.28% 87.72% 28.93% 48.30% 10.50% 1054 11.45% 88.55% 29.24% 48.73% 10.58%
989 12.27% 87.73% 28.93% 48.30% 10.50% 1055 11.45% 88.56% 29.24% 48.73% 10.59%
990 12.26% 87.74% 28.93% 48.31% 10.50% 1056 11.43% 88.57% 29.25% 48.74% 10.59%
991 12.25% 87.75% 28.94% 48.32% 10.50% 1057 11.42% 88.58% 29.25% 48.74% 10.59%
992 12.24% 87.76% 28.94% 48.32% 10.50% 1058 11.42% 88.58% 29.26% 48.74% 10.59%
993 12.22% 87.78% 28.95% 48.33% 10.50% 1059 11.40% 88.60% 29.26% 48.75% 10.59%
994 12.21% 87.79% 28.96% 48.34% 10.50% 1060 11.39% 88.61% 29.27% 48.76% 10.59%
995 12.20% 87.81% 28.96% 48.34% 10.50% 1061 11.38% 88.62% 29.27% 48.76% 10.59%
996 12.18% 87.83% 28.97% 48.35% 10.51% 1062 11.37% 88.63% 29.27% 48.76% 10.59%
997 12.16% 87.84% 28.98% 48.36% 10.51% 1063 11.36% 88.64% 29.28% 48.77% 10.60%
998 12.15% 87.85% 28.98% 48.36% 10.51% 1064 11.35% 88.65% 29.28% 48.77% 10.60%
999 12.13% 87.87% 28.98% 48.38% 10.51% 1065 11.34% 88.66% 29.28% 48.78% 10.60%
1000 12.11% 87.89% 28.99% 48.39% 10.51% 1066 11.33% 88.67% 29.28% 48.79% 10.60%
1001 12.10% 87.90% 29.00% 48.40% 10.51% 1067 11.32% 88.68% 29.29% 48.79% 10.60%
1002 12.09% 87.91% 29.00% 48.40% 10.51% 1068 11.31% 88.69% 29.29% 48.80% 10.60%
1003 12.08% 87.92% 29.00% 48.41% 10.52% 1069 11.30% 88.70% 29.29% 48.80% 10.60%
1004 12.07% 87.94% 29.01% 48.41% 10.52% 1070 11.30% 88.71% 29.29% 48.81% 10.60%
1005 12.05% 87.95% 29.01% 48.42% 10.52% 1071 11.28% 88.72% 29.30% 48.82% 10.60%
1006 12.04% 87.96% 29.01% 48.42% 10.52% 1072 11.26% 88.74% 29.30% 48.83% 10.61%
1007 12.02% 87.98% 29.02% 48.44% 10.52% 1073 11.25% 88.75% 29.31% 48.84% 10.61%
1008 12.01% 88.00% 29.03% 48.45% 10.52% 1074 11.24% 88.77% 29.31% 48.84% 10.61%
1009 11.99% 88.01% 29.03% 48.45% 10.53% 1075 11.23% 88.77% 29.32% 48.85% 10.61%
1010 11.99% 88.02% 29.03% 48.45% 10.53% 1076 11.22% 88.79% 29.32% 48.86% 10.61%
1011 11.97% 88.03% 29.04% 48.46% 10.53% 1077 11.20% 88.80% 29.33% 48.86% 10.61%
1012 11.96% 88.04% 29.05% 48.47% 10.53% 1078 11.19% 88.81% 29.34% 48.86% 10.61%
1013 11.95% 88.05% 29.05% 48.47% 10.53% 1079 11.19% 88.81% 29.34% 48.86% 10.61%
255
1080 11.18% 88.82% 29.34% 48.87% 10.61% 1146 10.41% 89.59% 29.65% 49.23% 10.71%
1081 11.17% 88.84% 29.35% 48.87% 10.61% 1147 10.40% 89.60% 29.66% 49.24% 10.71%
1082 11.15% 88.85% 29.35% 48.89% 10.62% 1148 10.39% 89.61% 29.66% 49.24% 10.71%
1083 11.14% 88.86% 29.35% 48.89% 10.62% 1149 10.38% 89.62% 29.67% 49.25% 10.71%
1084 11.12% 88.88% 29.36% 48.90% 10.62% 1150 10.36% 89.64% 29.68% 49.25% 10.71%
1085 11.11% 88.89% 29.36% 48.90% 10.63% 1151 10.36% 89.65% 29.68% 49.25% 10.71%
1086 11.11% 88.89% 29.37% 48.90% 10.63% 1152 10.35% 89.65% 29.68% 49.26% 10.71%
1087 11.10% 88.90% 29.37% 48.91% 10.63% 1153 10.34% 89.67% 29.69% 49.26% 10.72%
1088 11.09% 88.91% 29.37% 48.91% 10.63% 1154 10.32% 89.68% 29.69% 49.27% 10.72%
1089 11.08% 88.92% 29.38% 48.91% 10.63% 1155 10.31% 89.69% 29.70% 49.27% 10.72%
1090 11.06% 88.94% 29.39% 48.92% 10.63% 1156 10.29% 89.71% 29.70% 49.28% 10.72%
1091 11.05% 88.95% 29.39% 48.93% 10.63% 1157 10.28% 89.72% 29.71% 49.29% 10.72%
1092 11.04% 88.96% 29.39% 48.93% 10.63% 1158 10.28% 89.73% 29.71% 49.30% 10.72%
1093 11.03% 88.97% 29.40% 48.94% 10.63% 1159 10.27% 89.73% 29.71% 49.30% 10.72%
1094 11.02% 88.98% 29.40% 48.95% 10.63% 1160 10.26% 89.74% 29.71% 49.31% 10.72%
1095 11.01% 88.99% 29.40% 48.95% 10.64% 1161 10.25% 89.75% 29.71% 49.31% 10.72%
1096 10.99% 89.01% 29.41% 48.96% 10.64% 1162 10.24% 89.76% 29.72% 49.32% 10.72%
1097 10.98% 89.02% 29.42% 48.96% 10.64% 1163 10.23% 89.77% 29.72% 49.32% 10.73%
1098 10.97% 89.03% 29.42% 48.97% 10.64% 1164 10.22% 89.78% 29.73% 49.33% 10.73%
1099 10.96% 89.04% 29.43% 48.97% 10.64% 1165 10.22% 89.79% 29.73% 49.33% 10.73%
1100 10.95% 89.05% 29.43% 48.97% 10.65% 1166 10.21% 89.80% 29.73% 49.33% 10.73%
1101 10.94% 89.06% 29.44% 48.97% 10.65% 1167 10.19% 89.81% 29.74% 49.34% 10.73%
1102 10.93% 89.07% 29.44% 48.98% 10.65% 1168 10.18% 89.82% 29.75% 49.35% 10.73%
1103 10.92% 89.08% 29.44% 48.99% 10.65% 1169 10.16% 89.84% 29.75% 49.35% 10.73%
1104 10.91% 89.09% 29.45% 49.00% 10.65% 1170 10.16% 89.84% 29.76% 49.36% 10.73%
1105 10.89% 89.11% 29.45% 49.00% 10.65% 1171 10.15% 89.85% 29.76% 49.36% 10.73%
1106 10.87% 89.13% 29.46% 49.02% 10.65% 1172 10.13% 89.87% 29.76% 49.37% 10.74%
1107 10.86% 89.14% 29.46% 49.02% 10.65% 1173 10.12% 89.88% 29.77% 49.37% 10.74%
1108 10.85% 89.15% 29.47% 49.03% 10.65% 1174 10.12% 89.88% 29.77% 49.38% 10.74%
1109 10.84% 89.16% 29.48% 49.03% 10.66% 1175 10.11% 89.89% 29.77% 49.38% 10.74%
1110 10.83% 89.17% 29.48% 49.04% 10.66% 1176 10.10% 89.90% 29.78% 49.38% 10.74%
1111 10.82% 89.18% 29.48% 49.04% 10.66% 1177 10.10% 89.91% 29.78% 49.39% 10.74%
1112 10.80% 89.20% 29.49% 49.05% 10.66% 1178 10.09% 89.91% 29.78% 49.39% 10.74%
1113 10.79% 89.21% 29.50% 49.05% 10.66% 1179 10.08% 89.92% 29.78% 49.39% 10.74%
1114 10.77% 89.23% 29.51% 49.06% 10.66% 1180 10.07% 89.93% 29.79% 49.40% 10.74%
1115 10.77% 89.23% 29.51% 49.06% 10.66% 1181 10.06% 89.94% 29.79% 49.40% 10.74%
1116 10.76% 89.24% 29.51% 49.07% 10.66% 1182 10.05% 89.95% 29.80% 49.40% 10.75%
1117 10.76% 89.24% 29.51% 49.07% 10.67% 1183 10.04% 89.96% 29.80% 49.41% 10.75%
1118 10.74% 89.26% 29.52% 49.08% 10.67% 1184 10.03% 89.97% 29.81% 49.42% 10.75%
1119 10.73% 89.27% 29.52% 49.08% 10.67% 1185 10.02% 89.98% 29.81% 49.42% 10.75%
1120 10.71% 89.29% 29.53% 49.09% 10.67% 1186 10.00% 90.00% 29.82% 49.43% 10.75%
1121 10.70% 89.30% 29.53% 49.09% 10.67% 1187 9.99% 90.01% 29.82% 49.44% 10.75%
1122 10.69% 89.32% 29.54% 49.10% 10.68% 1188 9.98% 90.02% 29.83% 49.45% 10.75%
1123 10.68% 89.32% 29.54% 49.10% 10.68% 1189 9.97% 90.03% 29.83% 49.45% 10.75%
1124 10.67% 89.34% 29.55% 49.11% 10.68% 1190 9.96% 90.04% 29.83% 49.46% 10.75%
1125 10.65% 89.35% 29.56% 49.11% 10.68% 1191 9.96% 90.05% 29.84% 49.46% 10.75%
1126 10.64% 89.36% 29.56% 49.12% 10.68% 1192 9.94% 90.06% 29.84% 49.46% 10.75%
1127 10.63% 89.37% 29.57% 49.12% 10.68% 1193 9.94% 90.06% 29.84% 49.47% 10.75%
1128 10.61% 89.39% 29.57% 49.13% 10.69% 1194 9.93% 90.07% 29.84% 49.47% 10.76%
1129 10.60% 89.41% 29.58% 49.14% 10.69% 1195 9.91% 90.09% 29.85% 49.48% 10.76%
1130 10.59% 89.41% 29.59% 49.14% 10.69% 1196 9.90% 90.10% 29.85% 49.49% 10.76%
1131 10.58% 89.42% 29.59% 49.14% 10.69% 1197 9.89% 90.11% 29.86% 49.49% 10.76%
1132 10.57% 89.43% 29.59% 49.15% 10.69% 1198 9.88% 90.12% 29.86% 49.50% 10.76%
1133 10.56% 89.44% 29.60% 49.15% 10.69% 1199 9.86% 90.14% 29.86% 49.51% 10.77%
1134 10.54% 89.46% 29.61% 49.16% 10.69% 1200 9.85% 90.15% 29.87% 49.52% 10.77%
1135 10.53% 89.47% 29.61% 49.17% 10.69%
1136 10.52% 89.48% 29.61% 49.17% 10.70%
1137 10.51% 89.49% 29.62% 49.18% 10.70%
1138 10.50% 89.50% 29.62% 49.18% 10.70%
1139 10.49% 89.51% 29.63% 49.19% 10.70%
1140 10.48% 89.52% 29.63% 49.20% 10.70%
1141 10.46% 89.54% 29.64% 49.20% 10.70%
1142 10.46% 89.54% 29.64% 49.21% 10.70%
1143 10.45% 89.55% 29.64% 49.21% 10.70%
1144 10.44% 89.56% 29.65% 49.22% 10.70%
1145 10.43% 89.57% 29.65% 49.22% 10.70%
256
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA
-306 98.37% 1.63% 0.42% 1.21% 0.00%
-305 98.36% 1.64% 0.43% 1.21% 0.00%
Table B10. LOCA Probability History for ASP-09 -304 98.34% 1.66% 0.43% 1.23% 0.00%
for Days After TOD -303 98.33% 1.67% 0.43% 1.24% 0.00%
-302 98.31% 1.69% 0.44% 1.25% 0.00%
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA -301 98.29% 1.71% 0.44% 1.26% 0.00%
-365 98.97% 1.03% 0.29% 0.73% 0.00% -300 98.28% 1.72% 0.44% 1.27% 0.00%
-364 98.96% 1.04% 0.30% 0.74% 0.00% -299 98.27% 1.73% 0.44% 1.29% 0.00%
-363 98.96% 1.04% 0.30% 0.74% 0.00% -298 98.26% 1.74% 0.45% 1.30% 0.00%
-362 98.94% 1.06% 0.30% 0.75% 0.00% -297 98.24% 1.76% 0.45% 1.31% 0.00%
-361 98.94% 1.07% 0.31% 0.76% 0.00% -296 98.23% 1.77% 0.45% 1.31% 0.00%
-360 98.93% 1.07% 0.31% 0.76% 0.00% -295 98.22% 1.78% 0.45% 1.33% 0.00%
-359 98.92% 1.08% 0.31% 0.77% 0.00% -294 98.21% 1.79% 0.45% 1.34% 0.00%
-358 98.91% 1.09% 0.31% 0.78% 0.00% -293 98.20% 1.80% 0.45% 1.35% 0.00%
-357 98.90% 1.10% 0.31% 0.79% 0.00% -292 98.18% 1.82% 0.46% 1.36% 0.00%
-356 98.90% 1.11% 0.31% 0.79% 0.00% -291 98.16% 1.84% 0.46% 1.38% 0.00%
-355 98.89% 1.11% 0.31% 0.80% 0.00% -290 98.14% 1.86% 0.47% 1.40% 0.00%
-354 98.88% 1.12% 0.32% 0.80% 0.00% -289 98.12% 1.89% 0.47% 1.41% 0.00%
-353 98.87% 1.13% 0.32% 0.81% 0.00% -288 98.09% 1.91% 0.48% 1.43% 0.00%
-352 98.86% 1.14% 0.32% 0.82% 0.00% -287 98.07% 1.93% 0.48% 1.45% 0.00%
-351 98.86% 1.14% 0.32% 0.82% 0.00% -286 98.06% 1.94% 0.48% 1.46% 0.00%
-350 98.85% 1.15% 0.33% 0.83% 0.00% -285 98.04% 1.96% 0.49% 1.47% 0.00%
-349 98.84% 1.16% 0.33% 0.83% 0.00% -284 98.02% 1.98% 0.49% 1.49% 0.00%
-348 98.83% 1.17% 0.33% 0.84% 0.00% -283 98.01% 1.99% 0.49% 1.50% 0.00%
-347 98.82% 1.19% 0.33% 0.85% 0.00% -282 98.00% 2.01% 0.50% 1.51% 0.00%
-346 98.80% 1.20% 0.34% 0.86% 0.00% -281 97.97% 2.03% 0.50% 1.53% 0.00%
-345 98.79% 1.21% 0.34% 0.87% 0.00% -280 97.95% 2.05% 0.50% 1.55% 0.00%
-344 98.79% 1.21% 0.34% 0.87% 0.00% -279 97.94% 2.06% 0.50% 1.56% 0.00%
-343 98.78% 1.22% 0.34% 0.88% 0.00% -278 97.92% 2.08% 0.51% 1.57% 0.00%
-342 98.76% 1.24% 0.35% 0.89% 0.00% -277 97.91% 2.09% 0.51% 1.58% 0.00%
-341 98.75% 1.25% 0.35% 0.89% 0.00% -276 97.89% 2.11% 0.51% 1.60% 0.00%
-340 98.74% 1.26% 0.35% 0.90% 0.00% -275 97.87% 2.13% 0.52% 1.61% 0.00%
-339 98.73% 1.27% 0.36% 0.91% 0.00% -274 97.86% 2.14% 0.52% 1.62% 0.00%
-338 98.72% 1.28% 0.36% 0.92% 0.00% -273 97.84% 2.16% 0.52% 1.63% 0.00%
-337 98.72% 1.28% 0.36% 0.92% 0.00% -272 97.82% 2.18% 0.53% 1.65% 0.00%
-336 98.71% 1.29% 0.36% 0.93% 0.00% -271 97.82% 2.18% 0.53% 1.66% 0.00%
-335 98.69% 1.31% 0.36% 0.95% 0.00% -270 97.81% 2.19% 0.53% 1.66% 0.00%
-334 98.68% 1.32% 0.36% 0.95% 0.00% -269 97.78% 2.22% 0.53% 1.68% 0.00%
-333 98.67% 1.33% 0.36% 0.96% 0.00% -268 97.77% 2.23% 0.54% 1.69% 0.00%
-332 98.66% 1.34% 0.37% 0.97% 0.00% -267 97.76% 2.24% 0.54% 1.70% 0.00%
-331 98.65% 1.35% 0.37% 0.98% 0.00% -266 97.74% 2.27% 0.54% 1.72% 0.00%
-330 98.64% 1.36% 0.37% 0.99% 0.00% -265 97.72% 2.28% 0.55% 1.73% 0.00%
-329 98.64% 1.36% 0.37% 0.99% 0.00% -264 97.70% 2.30% 0.55% 1.75% 0.00%
-328 98.63% 1.38% 0.37% 1.00% 0.00% -263 97.68% 2.32% 0.55% 1.77% 0.00%
-327 98.61% 1.39% 0.37% 1.01% 0.00% -262 97.66% 2.34% 0.56% 1.78% 0.00%
-326 98.60% 1.40% 0.38% 1.02% 0.00% -261 97.63% 2.37% 0.56% 1.80% 0.00%
-325 98.59% 1.41% 0.38% 1.03% 0.00% -260 97.61% 2.39% 0.56% 1.82% 0.00%
-324 98.58% 1.42% 0.38% 1.04% 0.00% -259 97.60% 2.40% 0.57% 1.83% 0.00%
-323 98.56% 1.44% 0.39% 1.05% 0.00% -258 97.58% 2.42% 0.57% 1.85% 0.00%
-322 98.56% 1.45% 0.39% 1.06% 0.00% -257 97.55% 2.45% 0.57% 1.87% 0.00%
-321 98.55% 1.45% 0.39% 1.06% 0.00% -256 97.54% 2.46% 0.58% 1.88% 0.00%
-320 98.54% 1.46% 0.39% 1.07% 0.00% -255 97.51% 2.49% 0.59% 1.89% 0.00%
-319 98.53% 1.48% 0.39% 1.08% 0.00% -254 97.49% 2.51% 0.60% 1.91% 0.00%
-318 98.52% 1.48% 0.40% 1.09% 0.00% -253 97.47% 2.53% 0.60% 1.93% 0.00%
-317 98.51% 1.49% 0.40% 1.09% 0.00% -252 97.45% 2.55% 0.61% 1.94% 0.00%
-316 98.50% 1.50% 0.40% 1.11% 0.00% -251 97.43% 2.58% 0.61% 1.96% 0.00%
-315 98.49% 1.51% 0.40% 1.11% 0.00% -250 97.40% 2.61% 0.62% 1.98% 0.01%
-314 98.48% 1.52% 0.40% 1.12% 0.00% -249 97.37% 2.63% 0.62% 2.00% 0.01%
-313 98.47% 1.53% 0.40% 1.13% 0.00% -248 97.34% 2.66% 0.63% 2.03% 0.01%
-312 98.46% 1.55% 0.41% 1.14% 0.00% -247 97.32% 2.68% 0.63% 2.04% 0.01%
-311 98.45% 1.56% 0.41% 1.15% 0.00% -246 97.30% 2.71% 0.64% 2.06% 0.01%
-310 98.44% 1.56% 0.41% 1.15% 0.00% -245 97.28% 2.72% 0.64% 2.08% 0.01%
-309 98.42% 1.59% 0.42% 1.17% 0.00% -244 97.25% 2.75% 0.64% 2.10% 0.01%
-308 98.40% 1.60% 0.42% 1.18% 0.00% -243 97.24% 2.77% 0.64% 2.11% 0.01%
-307 98.38% 1.62% 0.42% 1.19% 0.00% -242 97.21% 2.79% 0.65% 2.13% 0.01%
257
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA
-241 97.19% 2.81% 0.65% 2.15% 0.01% -176 94.73% 5.27% 0.94% 4.12% 0.20%
-240 97.15% 2.85% 0.66% 2.18% 0.01% -175 94.68% 5.32% 0.95% 4.16% 0.21%
-239 97.12% 2.88% 0.66% 2.21% 0.01% -174 94.64% 5.36% 0.95% 4.19% 0.21%
-238 97.09% 2.91% 0.67% 2.23% 0.01% -173 94.58% 5.42% 0.96% 4.23% 0.23%
-237 97.07% 2.93% 0.67% 2.25% 0.01% -172 94.53% 5.48% 0.96% 4.27% 0.24%
-236 97.03% 2.97% 0.67% 2.28% 0.01% -171 94.48% 5.52% 0.97% 4.31% 0.25%
-235 97.00% 3.00% 0.68% 2.31% 0.02% -170 94.43% 5.57% 0.97% 4.34% 0.26%
-234 96.97% 3.04% 0.68% 2.34% 0.02% -169 94.36% 5.64% 0.98% 4.39% 0.27%
-233 96.94% 3.06% 0.68% 2.36% 0.02% -168 94.32% 5.69% 0.99% 4.42% 0.27%
-232 96.91% 3.09% 0.69% 2.39% 0.02% -167 94.26% 5.74% 0.99% 4.46% 0.28%
-231 96.87% 3.13% 0.69% 2.41% 0.02% -166 94.21% 5.79% 1.00% 4.50% 0.29%
-230 96.84% 3.16% 0.70% 2.44% 0.02% -165 94.17% 5.83% 1.00% 4.52% 0.30%
-229 96.81% 3.19% 0.70% 2.46% 0.02% -164 94.13% 5.87% 1.01% 4.55% 0.31%
-228 96.78% 3.22% 0.71% 2.49% 0.02% -163 94.08% 5.93% 1.01% 4.59% 0.32%
-227 96.75% 3.26% 0.71% 2.52% 0.02% -162 94.02% 5.98% 1.01% 4.63% 0.33%
-226 96.71% 3.29% 0.71% 2.55% 0.02% -161 93.96% 6.04% 1.02% 4.68% 0.35%
-225 96.68% 3.32% 0.72% 2.57% 0.03% -160 93.91% 6.09% 1.02% 4.71% 0.36%
-224 96.65% 3.35% 0.72% 2.59% 0.03% -159 93.85% 6.15% 1.03% 4.75% 0.37%
-223 96.62% 3.38% 0.73% 2.62% 0.03% -158 93.79% 6.21% 1.03% 4.79% 0.38%
-222 96.60% 3.40% 0.73% 2.64% 0.03% -157 93.74% 6.26% 1.03% 4.84% 0.39%
-221 96.57% 3.43% 0.74% 2.66% 0.03% -156 93.67% 6.33% 1.04% 4.89% 0.40%
-220 96.54% 3.46% 0.75% 2.69% 0.03% -155 93.60% 6.40% 1.05% 4.93% 0.42%
-219 96.50% 3.50% 0.75% 2.72% 0.03% -154 93.55% 6.45% 1.05% 4.96% 0.43%
-218 96.47% 3.53% 0.75% 2.74% 0.04% -153 93.49% 6.51% 1.06% 5.00% 0.45%
-217 96.44% 3.56% 0.76% 2.77% 0.04% -152 93.43% 6.57% 1.07% 5.04% 0.46%
-216 96.40% 3.61% 0.76% 2.80% 0.04% -151 93.38% 6.62% 1.07% 5.07% 0.48%
-215 96.36% 3.64% 0.77% 2.82% 0.04% -150 93.33% 6.67% 1.08% 5.10% 0.49%
-214 96.33% 3.68% 0.78% 2.85% 0.04% -149 93.27% 6.73% 1.08% 5.14% 0.50%
-213 96.29% 3.71% 0.78% 2.88% 0.05% -148 93.21% 6.80% 1.09% 5.19% 0.52%
-212 96.27% 3.73% 0.78% 2.90% 0.05% -147 93.13% 6.87% 1.09% 5.24% 0.53%
-211 96.23% 3.77% 0.79% 2.93% 0.05% -146 93.06% 6.95% 1.10% 5.29% 0.55%
-210 96.20% 3.81% 0.79% 2.96% 0.05% -145 92.98% 7.03% 1.11% 5.34% 0.58%
-209 96.16% 3.84% 0.80% 2.99% 0.05% -144 92.90% 7.10% 1.11% 5.39% 0.60%
-208 96.12% 3.88% 0.80% 3.02% 0.06% -143 92.82% 7.18% 1.12% 5.44% 0.62%
-207 96.09% 3.91% 0.80% 3.05% 0.06% -142 92.74% 7.26% 1.12% 5.50% 0.64%
-206 96.05% 3.95% 0.81% 3.08% 0.06% -141 92.66% 7.34% 1.13% 5.54% 0.66%
-205 96.01% 3.99% 0.81% 3.11% 0.06% -140 92.60% 7.40% 1.13% 5.58% 0.68%
-204 95.97% 4.03% 0.82% 3.14% 0.07% -139 92.52% 7.48% 1.14% 5.62% 0.71%
-203 95.94% 4.06% 0.82% 3.17% 0.07% -138 92.45% 7.55% 1.15% 5.67% 0.73%
-202 95.89% 4.11% 0.83% 3.21% 0.07% -137 92.38% 7.63% 1.16% 5.72% 0.75%
-201 95.86% 4.14% 0.83% 3.23% 0.08% -136 92.30% 7.70% 1.16% 5.77% 0.76%
-200 95.82% 4.18% 0.84% 3.26% 0.08% -135 92.24% 7.76% 1.17% 5.81% 0.78%
-199 95.78% 4.22% 0.84% 3.30% 0.08% -134 92.17% 7.83% 1.18% 5.86% 0.79%
-198 95.73% 4.27% 0.85% 3.34% 0.08% -133 92.08% 7.92% 1.18% 5.92% 0.82%
-197 95.69% 4.31% 0.85% 3.37% 0.09% -132 92.01% 7.99% 1.19% 5.97% 0.83%
-196 95.64% 4.36% 0.85% 3.41% 0.09% -131 91.94% 8.06% 1.20% 6.01% 0.85%
-195 95.61% 4.39% 0.86% 3.43% 0.09% -130 91.86% 8.14% 1.21% 6.06% 0.87%
-194 95.58% 4.42% 0.86% 3.46% 0.10% -129 91.79% 8.21% 1.21% 6.10% 0.90%
-193 95.54% 4.47% 0.87% 3.49% 0.10% -128 91.72% 8.28% 1.21% 6.15% 0.91%
-192 95.50% 4.51% 0.87% 3.53% 0.10% -127 91.65% 8.35% 1.22% 6.19% 0.93%
-191 95.46% 4.54% 0.88% 3.55% 0.11% -126 91.57% 8.43% 1.22% 6.25% 0.95%
-190 95.41% 4.59% 0.88% 3.59% 0.12% -125 91.48% 8.52% 1.23% 6.32% 0.97%
-189 95.36% 4.64% 0.89% 3.63% 0.12% -124 91.39% 8.61% 1.23% 6.38% 1.00%
-188 95.32% 4.68% 0.89% 3.66% 0.13% -123 91.30% 8.70% 1.24% 6.43% 1.02%
-187 95.28% 4.72% 0.89% 3.70% 0.13% -122 91.22% 8.78% 1.24% 6.48% 1.05%
-186 95.23% 4.77% 0.90% 3.73% 0.14% -121 91.16% 8.85% 1.25% 6.53% 1.07%
-185 95.19% 4.81% 0.90% 3.77% 0.14% -120 91.09% 8.91% 1.25% 6.57% 1.09%
-184 95.14% 4.86% 0.90% 3.80% 0.15% -119 91.01% 8.99% 1.26% 6.62% 1.12%
-183 95.10% 4.90% 0.91% 3.84% 0.16% -118 90.93% 9.07% 1.27% 6.66% 1.15%
-182 95.06% 4.95% 0.91% 3.87% 0.16% -117 90.84% 9.16% 1.27% 6.71% 1.17%
-181 95.01% 4.99% 0.92% 3.91% 0.17% -116 90.77% 9.23% 1.27% 6.76% 1.20%
-180 94.95% 5.05% 0.92% 3.96% 0.17% -115 90.68% 9.32% 1.28% 6.81% 1.23%
-179 94.90% 5.10% 0.93% 3.99% 0.18% -114 90.61% 9.39% 1.29% 6.86% 1.25%
-178 94.85% 5.16% 0.93% 4.04% 0.19% -113 90.52% 9.48% 1.29% 6.91% 1.28%
-177 94.79% 5.21% 0.94% 4.08% 0.19% -112 90.42% 9.58% 1.29% 6.97% 1.32%
258
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA
-111 90.34% 9.66% 1.30% 7.01% 1.35% -46 82.93% 17.07% 1.71% 10.91% 4.45%
-110 90.24% 9.76% 1.31% 7.06% 1.39% -45 82.80% 17.20% 1.71% 10.97% 4.52%
-109 90.14% 9.86% 1.32% 7.11% 1.43% -44 82.65% 17.35% 1.72% 11.04% 4.59%
-108 90.07% 9.93% 1.32% 7.16% 1.45% -43 82.52% 17.49% 1.73% 11.10% 4.66%
-107 89.98% 10.02% 1.33% 7.21% 1.49% -42 82.37% 17.63% 1.73% 11.17% 4.72%
-106 89.90% 10.10% 1.33% 7.25% 1.51% -41 82.24% 17.76% 1.73% 11.24% 4.79%
-105 89.81% 10.19% 1.34% 7.30% 1.55% -40 82.09% 17.91% 1.74% 11.32% 4.85%
-104 89.72% 10.28% 1.34% 7.35% 1.58% -39 81.93% 18.07% 1.75% 11.39% 4.92%
-103 89.62% 10.39% 1.35% 7.41% 1.62% -38 81.80% 18.20% 1.76% 11.45% 4.99%
-102 89.52% 10.48% 1.35% 7.47% 1.66% -37 81.66% 18.34% 1.77% 11.52% 5.05%
-101 89.41% 10.59% 1.36% 7.53% 1.70% -36 81.50% 18.50% 1.78% 11.58% 5.13%
-100 89.31% 10.69% 1.36% 7.59% 1.74% -35 81.34% 18.66% 1.78% 11.65% 5.22%
-99 89.22% 10.78% 1.37% 7.64% 1.77% -34 81.20% 18.80% 1.79% 11.72% 5.29%
-98 89.10% 10.91% 1.38% 7.71% 1.81% -33 81.04% 18.96% 1.80% 11.80% 5.37%
-97 88.99% 11.01% 1.39% 7.77% 1.85% -32 80.87% 19.13% 1.80% 11.86% 5.47%
-96 88.90% 11.10% 1.39% 7.82% 1.89% -31 80.71% 19.29% 1.80% 11.94% 5.55%
-95 88.79% 11.21% 1.40% 7.88% 1.92% -30 80.56% 19.44% 1.81% 12.02% 5.62%
-94 88.68% 11.32% 1.41% 7.94% 1.97% -29 80.39% 19.61% 1.81% 12.09% 5.71%
-93 88.56% 11.44% 1.42% 8.00% 2.02% -28 80.26% 19.74% 1.82% 12.15% 5.77%
-92 88.48% 11.52% 1.42% 8.04% 2.05% -27 80.11% 19.89% 1.83% 12.21% 5.85%
-91 88.38% 11.62% 1.43% 8.10% 2.09% -26 79.95% 20.05% 1.83% 12.28% 5.93%
-90 88.27% 11.73% 1.44% 8.16% 2.13% -25 79.77% 20.23% 1.84% 12.37% 6.02%
-89 88.17% 11.83% 1.44% 8.21% 2.17% -24 79.60% 20.40% 1.85% 12.44% 6.11%
-88 88.08% 11.93% 1.44% 8.27% 2.22% -23 79.46% 20.54% 1.85% 12.50% 6.19%
-87 87.98% 12.02% 1.45% 8.33% 2.25% -22 79.31% 20.69% 1.86% 12.56% 6.27%
-86 87.87% 12.13% 1.45% 8.38% 2.29% -21 79.17% 20.83% 1.87% 12.63% 6.34%
-85 87.78% 12.22% 1.46% 8.43% 2.33% -20 79.00% 21.00% 1.87% 12.70% 6.43%
-84 87.67% 12.33% 1.46% 8.49% 2.37% -19 78.83% 21.17% 1.88% 12.78% 6.52%
-83 87.56% 12.44% 1.47% 8.56% 2.41% -18 78.67% 21.33% 1.88% 12.85% 6.60%
-82 87.46% 12.54% 1.47% 8.61% 2.45% -17 78.50% 21.50% 1.89% 12.93% 6.68%
-81 87.36% 12.65% 1.48% 8.67% 2.49% -16 78.33% 21.67% 1.90% 13.01% 6.77%
-80 87.23% 12.77% 1.49% 8.73% 2.55% -15 78.17% 21.83% 1.90% 13.08% 6.85%
-79 87.12% 12.88% 1.49% 8.78% 2.60% -14 78.01% 21.99% 1.91% 13.15% 6.93%
-78 87.01% 12.99% 1.49% 8.85% 2.65% -13 77.86% 22.14% 1.92% 13.21% 7.01%
-77 86.90% 13.10% 1.50% 8.90% 2.70% -12 77.71% 22.29% 1.92% 13.27% 7.10%
-76 86.76% 13.24% 1.51% 8.98% 2.75% -11 77.55% 22.45% 1.92% 13.34% 7.18%
-75 86.66% 13.35% 1.51% 9.04% 2.79% -10 77.37% 22.64% 1.93% 13.43% 7.27%
-74 86.52% 13.48% 1.52% 9.11% 2.85% -9 77.19% 22.81% 1.94% 13.50% 7.37%
-73 86.41% 13.59% 1.52% 9.17% 2.89% -8 76.99% 23.01% 1.95% 13.59% 7.47%
-72 86.29% 13.71% 1.53% 9.23% 2.95% -7 76.81% 23.19% 1.96% 13.67% 7.56%
-71 86.17% 13.83% 1.54% 9.29% 3.01% -6 76.65% 23.35% 1.96% 13.74% 7.64%
-70 86.05% 13.96% 1.55% 9.35% 3.06% -5 76.46% 23.54% 1.97% 13.83% 7.74%
-69 85.92% 14.08% 1.55% 9.42% 3.11% -4 76.30% 23.70% 1.98% 13.91% 7.82%
-68 85.81% 14.19% 1.55% 9.47% 3.16% -3 76.15% 23.86% 1.98% 13.96% 7.91%
-67 85.69% 14.31% 1.56% 9.53% 3.23% -2 75.99% 24.01% 1.99% 14.03% 7.99%
-66 85.56% 14.44% 1.56% 9.60% 3.28% -1 75.82% 24.18% 2.00% 14.10% 8.07%
-65 85.44% 14.56% 1.57% 9.65% 3.34% 0 75.25% 24.76% 2.01% 14.18% 8.57%
-64 85.34% 14.66% 1.58% 9.70% 3.39% 1 75.08% 24.92% 2.01% 14.26% 8.65%
-63 85.21% 14.79% 1.58% 9.77% 3.44% 2 74.81% 25.20% 2.01% 14.33% 8.84%
-62 85.07% 14.93% 1.59% 9.84% 3.49% 3 74.61% 25.39% 2.02% 14.40% 8.97%
-61 84.96% 15.04% 1.60% 9.90% 3.54% 4 74.43% 25.57% 2.02% 14.47% 9.08%
-60 84.84% 15.16% 1.61% 9.96% 3.58% 5 74.23% 25.77% 2.03% 14.55% 9.19%
-59 84.71% 15.29% 1.62% 10.03% 3.65% 6 74.05% 25.95% 2.04% 14.62% 9.29%
-58 84.58% 15.42% 1.62% 10.09% 3.70% 7 73.85% 26.15% 2.05% 14.70% 9.40%
-57 84.43% 15.57% 1.63% 10.17% 3.77% 8 73.68% 26.32% 2.05% 14.78% 9.49%
-56 84.31% 15.69% 1.64% 10.22% 3.83% 9 73.50% 26.51% 2.06% 14.85% 9.59%
-55 84.17% 15.83% 1.65% 10.29% 3.89% 10 73.34% 26.66% 2.07% 14.93% 9.67%
-54 84.05% 15.95% 1.65% 10.35% 3.95% 11 73.15% 26.85% 2.08% 15.02% 9.76%
-53 83.91% 16.09% 1.66% 10.41% 4.02% 12 72.99% 27.01% 2.08% 15.09% 9.84%
-52 83.77% 16.23% 1.67% 10.49% 4.08% 13 72.82% 27.18% 2.09% 15.15% 9.94%
-51 83.66% 16.34% 1.67% 10.55% 4.12% 14 72.62% 27.38% 2.10% 15.25% 10.03%
-50 83.52% 16.48% 1.68% 10.63% 4.17% 15 72.45% 27.55% 2.10% 15.33% 10.11%
-49 83.37% 16.63% 1.69% 10.69% 4.25% 16 72.24% 27.76% 2.10% 15.43% 10.23%
-48 83.22% 16.78% 1.69% 10.77% 4.32% 17 72.08% 27.92% 2.11% 15.50% 10.32%
-47 83.07% 16.93% 1.70% 10.84% 4.39% 18 71.93% 28.07% 2.11% 15.56% 10.39%
259
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 19 71.72% 28.28% 2.12% 15.64% 10.52% 84 60.47% 39.53% 2.52% 20.88% 16.12%
20 71.54% 28.46% 2.13% 15.72% 10.61% 85 60.33% 39.67% 2.52% 20.96% 16.18%
21 71.36% 28.64% 2.14% 15.79% 10.71% 86 60.17% 39.84% 2.52% 21.05% 16.26%
22 71.18% 28.82% 2.15% 15.88% 10.79% 87 60.01% 39.99% 2.53% 21.12% 16.34%
23 71.01% 29.00% 2.16% 15.96% 10.88% 88 59.85% 40.15% 2.54% 21.21% 16.41%
24 70.83% 29.17% 2.16% 16.05% 10.97% 89 59.71% 40.29% 2.54% 21.28% 16.47%
25 70.63% 29.37% 2.17% 16.11% 11.09% 90 59.56% 40.44% 2.55% 21.35% 16.54%
26 70.44% 29.57% 2.17% 16.20% 11.19% 91 59.39% 40.61% 2.55% 21.44% 16.61%
27 70.26% 29.74% 2.18% 16.28% 11.28% 92 59.22% 40.78% 2.56% 21.52% 16.70%
28 70.07% 29.93% 2.19% 16.36% 11.38% 93 59.07% 40.93% 2.57% 21.60% 16.76%
29 69.89% 30.11% 2.19% 16.43% 11.48% 94 58.89% 41.11% 2.57% 21.68% 16.85%
30 69.71% 30.29% 2.20% 16.52% 11.57% 95 58.73% 41.27% 2.58% 21.77% 16.92%
31 69.52% 30.48% 2.20% 16.60% 11.68% 96 58.56% 41.44% 2.58% 21.85% 17.01%
32 69.33% 30.67% 2.21% 16.68% 11.78% 97 58.39% 41.61% 2.59% 21.92% 17.10%
33 69.14% 30.86% 2.22% 16.75% 11.88% 98 58.22% 41.79% 2.59% 22.00% 17.19%
34 68.96% 31.04% 2.23% 16.83% 11.98% 99 58.04% 41.96% 2.59% 22.09% 17.27%
35 68.79% 31.21% 2.24% 16.89% 12.08% 100 57.88% 42.12% 2.60% 22.17% 17.35%
36 68.64% 31.36% 2.24% 16.95% 12.17% 101 57.73% 42.27% 2.60% 22.24% 17.42%
37 68.46% 31.54% 2.25% 17.03% 12.27% 102 57.56% 42.44% 2.61% 22.31% 17.52%
38 68.28% 31.72% 2.25% 17.11% 12.36% 103 57.40% 42.60% 2.61% 22.39% 17.59%
39 68.12% 31.88% 2.26% 17.17% 12.44% 104 57.24% 42.76% 2.62% 22.47% 17.67%
40 67.94% 32.06% 2.27% 17.25% 12.55% 105 57.09% 42.91% 2.62% 22.54% 17.75%
41 67.75% 32.25% 2.27% 17.34% 12.64% 106 56.94% 43.06% 2.62% 22.62% 17.82%
42 67.56% 32.44% 2.28% 17.44% 12.72% 107 56.76% 43.24% 2.63% 22.71% 17.90%
43 67.39% 32.61% 2.29% 17.51% 12.81% 108 56.60% 43.40% 2.63% 22.79% 17.98%
44 67.22% 32.78% 2.30% 17.58% 12.89% 109 56.41% 43.59% 2.64% 22.88% 18.07%
45 67.04% 32.96% 2.31% 17.67% 12.98% 110 56.26% 43.74% 2.64% 22.95% 18.15%
46 66.84% 33.16% 2.31% 17.76% 13.08% 111 56.10% 43.90% 2.64% 23.03% 18.23%
47 66.64% 33.36% 2.32% 17.87% 13.17% 112 55.94% 44.06% 2.65% 23.10% 18.32%
48 66.45% 33.55% 2.33% 17.95% 13.26% 113 55.78% 44.22% 2.65% 23.17% 18.41%
49 66.30% 33.70% 2.33% 18.03% 13.33% 114 55.63% 44.37% 2.65% 23.23% 18.49%
50 66.12% 33.88% 2.34% 18.11% 13.43% 115 55.47% 44.53% 2.65% 23.31% 18.56%
51 65.95% 34.05% 2.35% 18.19% 13.51% 116 55.33% 44.68% 2.66% 23.40% 18.62%
52 65.78% 34.22% 2.36% 18.26% 13.60% 117 55.19% 44.81% 2.66% 23.46% 18.69%
53 65.62% 34.38% 2.36% 18.33% 13.69% 118 55.06% 44.94% 2.67% 23.52% 18.75%
54 65.46% 34.54% 2.36% 18.41% 13.77% 119 54.92% 45.08% 2.67% 23.59% 18.82%
55 65.29% 34.71% 2.37% 18.50% 13.84% 120 54.73% 45.27% 2.67% 23.68% 18.92%
56 65.14% 34.86% 2.37% 18.58% 13.91% 121 54.58% 45.42% 2.68% 23.74% 19.00%
57 64.98% 35.02% 2.38% 18.66% 13.98% 122 54.42% 45.58% 2.68% 23.82% 19.08%
58 64.82% 35.18% 2.38% 18.73% 14.06% 123 54.26% 45.74% 2.68% 23.90% 19.16%
59 64.65% 35.35% 2.38% 18.81% 14.15% 124 54.12% 45.89% 2.69% 23.95% 19.24%
60 64.47% 35.53% 2.39% 18.91% 14.23% 125 53.96% 46.04% 2.69% 24.02% 19.32%
61 64.31% 35.69% 2.40% 18.99% 14.31% 126 53.80% 46.20% 2.69% 24.10% 19.40%
62 64.12% 35.88% 2.40% 19.08% 14.39% 127 53.65% 46.35% 2.70% 24.18% 19.47%
63 63.94% 36.06% 2.41% 19.17% 14.48% 128 53.48% 46.52% 2.70% 24.27% 19.54%
64 63.79% 36.21% 2.41% 19.24% 14.55% 129 53.33% 46.67% 2.71% 24.34% 19.62%
65 63.63% 36.37% 2.42% 19.33% 14.63% 130 53.19% 46.81% 2.71% 24.41% 19.69%
66 63.45% 36.55% 2.43% 19.42% 14.70% 131 53.04% 46.96% 2.71% 24.48% 19.76%
67 63.29% 36.72% 2.43% 19.50% 14.78% 132 52.90% 47.10% 2.72% 24.56% 19.82%
68 63.12% 36.88% 2.43% 19.59% 14.86% 133 52.73% 47.27% 2.72% 24.63% 19.91%
69 62.96% 37.05% 2.44% 19.68% 14.93% 134 52.57% 47.43% 2.73% 24.71% 19.99%
70 62.78% 37.22% 2.44% 19.78% 15.01% 135 52.41% 47.59% 2.73% 24.78% 20.07%
71 62.62% 37.38% 2.44% 19.86% 15.08% 136 52.26% 47.74% 2.74% 24.86% 20.13%
72 62.46% 37.54% 2.45% 19.93% 15.16% 137 52.11% 47.89% 2.75% 24.93% 20.21%
73 62.31% 37.70% 2.46% 20.01% 15.23% 138 51.96% 48.04% 2.75% 25.01% 20.28%
74 62.13% 37.87% 2.47% 20.10% 15.30% 139 51.79% 48.21% 2.76% 25.08% 20.37%
75 61.99% 38.01% 2.47% 20.17% 15.37% 140 51.65% 48.35% 2.76% 25.15% 20.43%
76 61.82% 38.18% 2.48% 20.24% 15.45% 141 51.52% 48.48% 2.77% 25.20% 20.50%
77 61.65% 38.35% 2.49% 20.32% 15.54% 142 51.37% 48.63% 2.77% 25.28% 20.58%
78 61.46% 38.54% 2.49% 20.41% 15.63% 143 51.22% 48.78% 2.77% 25.34% 20.66%
79 61.31% 38.69% 2.50% 20.49% 15.71% 144 51.07% 48.93% 2.78% 25.41% 20.73%
80 61.13% 38.87% 2.50% 20.56% 15.80% 145 50.93% 49.07% 2.79% 25.48% 20.81%
81 60.98% 39.02% 2.51% 20.64% 15.87% 146 50.78% 49.22% 2.79% 25.54% 20.89%
82 60.82% 39.18% 2.51% 20.72% 15.95% 147 50.62% 49.38% 2.79% 25.62% 20.97%
83 60.65% 39.35% 2.52% 20.79% 16.04% 148 50.46% 49.54% 2.80% 25.69% 21.05%
260
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 149 50.32% 49.68% 2.80% 25.76% 21.12% 214 42.22% 57.78% 2.99% 29.81% 24.98%
150 50.17% 49.83% 2.81% 25.83% 21.19% 215 42.11% 57.89% 2.99% 29.86% 25.04%
151 50.04% 49.96% 2.81% 25.90% 21.25% 216 41.99% 58.01% 2.99% 29.92% 25.10%
152 49.90% 50.10% 2.82% 25.97% 21.32% 217 41.86% 58.14% 3.00% 29.98% 25.16%
153 49.75% 50.25% 2.82% 26.05% 21.38% 218 41.74% 58.26% 3.00% 30.04% 25.22%
154 49.60% 50.40% 2.82% 26.12% 21.46% 219 41.65% 58.35% 3.00% 30.09% 25.26%
155 49.48% 50.53% 2.83% 26.18% 21.51% 220 41.56% 58.44% 3.00% 30.13% 25.31%
156 49.32% 50.68% 2.83% 26.25% 21.60% 221 41.44% 58.56% 3.00% 30.19% 25.37%
157 49.17% 50.83% 2.84% 26.33% 21.67% 222 41.32% 58.68% 3.00% 30.25% 25.43%
158 49.01% 51.00% 2.84% 26.41% 21.75% 223 41.20% 58.80% 3.00% 30.31% 25.48%
159 48.86% 51.14% 2.84% 26.47% 21.83% 224 41.09% 58.91% 3.01% 30.36% 25.54%
160 48.72% 51.28% 2.84% 26.53% 21.90% 225 40.98% 59.02% 3.01% 30.41% 25.59%
161 48.59% 51.41% 2.84% 26.59% 21.97% 226 40.87% 59.13% 3.01% 30.47% 25.64%
162 48.45% 51.55% 2.85% 26.66% 22.03% 227 40.78% 59.22% 3.02% 30.51% 25.69%
163 48.31% 51.69% 2.86% 26.72% 22.11% 228 40.68% 59.33% 3.02% 30.57% 25.73%
164 48.17% 51.83% 2.86% 26.79% 22.18% 229 40.57% 59.43% 3.02% 30.63% 25.78%
165 48.06% 51.94% 2.86% 26.84% 22.23% 230 40.44% 59.56% 3.02% 30.70% 25.84%
166 47.91% 52.09% 2.87% 26.92% 22.31% 231 40.35% 59.65% 3.02% 30.74% 25.89%
167 47.78% 52.22% 2.87% 26.97% 22.37% 232 40.24% 59.76% 3.02% 30.80% 25.94%
168 47.66% 52.34% 2.88% 27.03% 22.43% 233 40.12% 59.88% 3.02% 30.86% 25.99%
169 47.51% 52.49% 2.88% 27.11% 22.50% 234 40.02% 59.98% 3.03% 30.91% 26.04%
170 47.39% 52.61% 2.88% 27.17% 22.56% 235 39.94% 60.07% 3.03% 30.95% 26.08%
171 47.27% 52.73% 2.88% 27.22% 22.62% 236 39.83% 60.17% 3.03% 31.01% 26.13%
172 47.16% 52.84% 2.88% 27.27% 22.68% 237 39.73% 60.27% 3.03% 31.06% 26.18%
173 47.04% 52.96% 2.89% 27.34% 22.73% 238 39.63% 60.37% 3.03% 31.11% 26.22%
174 46.90% 53.10% 2.89% 27.40% 22.80% 239 39.54% 60.46% 3.04% 31.17% 26.26%
175 46.78% 53.22% 2.90% 27.46% 22.86% 240 39.44% 60.56% 3.04% 31.21% 26.31%
176 46.64% 53.36% 2.90% 27.54% 22.92% 241 39.35% 60.65% 3.04% 31.25% 26.36%
177 46.49% 53.51% 2.91% 27.61% 22.99% 242 39.27% 60.73% 3.04% 31.29% 26.40%
178 46.37% 53.63% 2.91% 27.68% 23.04% 243 39.16% 60.84% 3.04% 31.34% 26.45%
179 46.24% 53.76% 2.92% 27.74% 23.10% 244 39.03% 60.97% 3.04% 31.41% 26.52%
180 46.11% 53.89% 2.92% 27.81% 23.16% 245 38.93% 61.07% 3.04% 31.45% 26.57%
181 45.99% 54.01% 2.92% 27.87% 23.22% 246 38.83% 61.17% 3.05% 31.50% 26.62%
182 45.88% 54.12% 2.92% 27.92% 23.27% 247 38.74% 61.27% 3.05% 31.54% 26.68%
183 45.77% 54.23% 2.93% 27.98% 23.32% 248 38.65% 61.35% 3.05% 31.57% 26.72%
184 45.66% 54.34% 2.93% 28.04% 23.36% 249 38.54% 61.46% 3.05% 31.63% 26.78%
185 45.56% 54.45% 2.93% 28.10% 23.42% 250 38.45% 61.55% 3.05% 31.68% 26.82%
186 45.43% 54.57% 2.93% 28.16% 23.48% 251 38.35% 61.65% 3.05% 31.74% 26.86%
187 45.31% 54.69% 2.93% 28.21% 23.54% 252 38.26% 61.74% 3.06% 31.78% 26.90%
188 45.21% 54.80% 2.93% 28.26% 23.59% 253 38.17% 61.83% 3.06% 31.83% 26.95%
189 45.09% 54.91% 2.93% 28.32% 23.65% 254 38.07% 61.93% 3.06% 31.88% 26.99%
190 44.97% 55.03% 2.94% 28.39% 23.70% 255 38.00% 62.00% 3.06% 31.92% 27.02%
191 44.84% 55.16% 2.94% 28.46% 23.76% 256 37.91% 62.09% 3.06% 31.96% 27.06%
192 44.71% 55.29% 2.94% 28.53% 23.82% 257 37.82% 62.18% 3.07% 32.02% 27.10%
193 44.61% 55.40% 2.94% 28.57% 23.88% 258 37.72% 62.28% 3.07% 32.07% 27.14%
194 44.48% 55.52% 2.95% 28.63% 23.94% 259 37.61% 62.39% 3.07% 32.13% 27.19%
195 44.37% 55.63% 2.95% 28.68% 24.00% 260 37.53% 62.47% 3.07% 32.17% 27.23%
196 44.25% 55.75% 2.95% 28.75% 24.05% 261 37.44% 62.57% 3.07% 32.22% 27.27%
197 44.15% 55.85% 2.95% 28.81% 24.09% 262 37.36% 62.64% 3.07% 32.26% 27.31%
198 44.03% 55.97% 2.95% 28.87% 24.14% 263 37.25% 62.75% 3.08% 32.32% 27.36%
199 43.92% 56.08% 2.95% 28.93% 24.20% 264 37.15% 62.85% 3.08% 32.38% 27.40%
200 43.80% 56.20% 2.96% 29.00% 24.25% 265 37.07% 62.93% 3.08% 32.42% 27.43%
201 43.70% 56.30% 2.96% 29.06% 24.28% 266 36.97% 63.03% 3.08% 32.47% 27.47%
202 43.58% 56.42% 2.96% 29.13% 24.33% 267 36.89% 63.11% 3.08% 32.52% 27.51%
203 43.47% 56.53% 2.96% 29.18% 24.39% 268 36.77% 63.23% 3.08% 32.58% 27.57%
204 43.36% 56.64% 2.96% 29.24% 24.44% 269 36.68% 63.32% 3.08% 32.62% 27.62%
205 43.24% 56.77% 2.97% 29.30% 24.50% 270 36.58% 63.42% 3.08% 32.67% 27.66%
206 43.12% 56.88% 2.97% 29.36% 24.56% 271 36.51% 63.49% 3.09% 32.71% 27.69%
207 43.01% 56.99% 2.97% 29.41% 24.61% 272 36.42% 63.58% 3.09% 32.76% 27.73%
208 42.89% 57.11% 2.97% 29.47% 24.66% 273 36.32% 63.68% 3.09% 32.82% 27.77%
209 42.78% 57.22% 2.98% 29.53% 24.71% 274 36.21% 63.79% 3.09% 32.87% 27.83%
210 42.66% 57.34% 2.98% 29.58% 24.77% 275 36.12% 63.88% 3.09% 32.92% 27.87%
211 42.55% 57.45% 2.98% 29.64% 24.82% 276 36.04% 63.96% 3.09% 32.95% 27.92%
212 42.44% 57.56% 2.98% 29.70% 24.88% 277 35.95% 64.05% 3.09% 33.00% 27.96%
213 42.32% 57.68% 2.99% 29.76% 24.94% 278 35.86% 64.14% 3.09% 33.05% 28.00%
261
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 279 35.78% 64.22% 3.09% 33.10% 28.03% 344 30.63% 69.37% 3.13% 35.79% 30.45%
280 35.69% 64.31% 3.10% 33.14% 28.07% 345 30.56% 69.44% 3.13% 35.83% 30.48%
281 35.61% 64.39% 3.10% 33.19% 28.11% 346 30.49% 69.51% 3.13% 35.87% 30.51%
282 35.52% 64.48% 3.10% 33.23% 28.15% 347 30.42% 69.58% 3.13% 35.90% 30.55%
283 35.45% 64.55% 3.10% 33.26% 28.19% 348 30.34% 69.66% 3.13% 35.94% 30.58%
284 35.35% 64.65% 3.10% 33.30% 28.25% 349 30.27% 69.73% 3.13% 35.98% 30.62%
285 35.26% 64.74% 3.10% 33.35% 28.28% 350 30.21% 69.80% 3.13% 36.01% 30.65%
286 35.17% 64.83% 3.10% 33.40% 28.33% 351 30.15% 69.85% 3.13% 36.05% 30.67%
287 35.09% 64.91% 3.10% 33.45% 28.36% 352 30.09% 69.91% 3.13% 36.08% 30.69%
288 35.00% 65.00% 3.10% 33.50% 28.40% 353 30.03% 69.97% 3.13% 36.11% 30.72%
289 34.89% 65.11% 3.10% 33.56% 28.45% 354 29.96% 70.05% 3.13% 36.16% 30.76%
290 34.79% 65.22% 3.10% 33.61% 28.50% 355 29.88% 70.12% 3.13% 36.20% 30.79%
291 34.72% 65.28% 3.10% 33.65% 28.52% 356 29.81% 70.19% 3.13% 36.24% 30.81%
292 34.64% 65.36% 3.10% 33.70% 28.56% 357 29.74% 70.26% 3.13% 36.28% 30.85%
293 34.55% 65.45% 3.10% 33.74% 28.60% 358 29.68% 70.32% 3.13% 36.31% 30.87%
294 34.47% 65.54% 3.10% 33.78% 28.65% 359 29.62% 70.38% 3.13% 36.34% 30.91%
295 34.38% 65.62% 3.10% 33.82% 28.69% 360 29.56% 70.44% 3.13% 36.37% 30.94%
296 34.30% 65.70% 3.10% 33.86% 28.73% 361 29.49% 70.51% 3.13% 36.40% 30.97%
297 34.23% 65.78% 3.10% 33.91% 28.76% 362 29.43% 70.57% 3.13% 36.43% 31.00%
298 34.16% 65.85% 3.10% 33.95% 28.79% 363 29.37% 70.64% 3.14% 36.47% 31.03%
299 34.06% 65.94% 3.11% 34.00% 28.84% 364 29.29% 70.71% 3.14% 36.51% 31.07%
300 33.99% 66.01% 3.11% 34.03% 28.87% 365 29.21% 70.79% 3.14% 36.55% 31.11%
301 33.92% 66.09% 3.11% 34.07% 28.91% 366 29.13% 70.87% 3.14% 36.58% 31.14%
302 33.82% 66.18% 3.11% 34.12% 28.95% 367 29.07% 70.93% 3.14% 36.63% 31.17%
303 33.73% 66.28% 3.11% 34.17% 28.99% 368 29.00% 71.00% 3.14% 36.66% 31.20%
304 33.66% 66.34% 3.11% 34.21% 29.03% 369 28.93% 71.07% 3.14% 36.70% 31.23%
305 33.58% 66.43% 3.11% 34.26% 29.06% 370 28.87% 71.13% 3.14% 36.73% 31.26%
306 33.49% 66.51% 3.11% 34.30% 29.11% 371 28.81% 71.19% 3.14% 36.76% 31.28%
307 33.41% 66.59% 3.11% 34.34% 29.14% 372 28.75% 71.25% 3.14% 36.80% 31.31%
308 33.33% 66.67% 3.11% 34.38% 29.18% 373 28.66% 71.34% 3.14% 36.84% 31.35%
309 33.25% 66.75% 3.11% 34.42% 29.21% 374 28.60% 71.40% 3.14% 36.87% 31.38%
310 33.17% 66.83% 3.11% 34.46% 29.26% 375 28.55% 71.45% 3.14% 36.90% 31.41%
311 33.09% 66.91% 3.11% 34.49% 29.30% 376 28.48% 71.52% 3.14% 36.94% 31.44%
312 33.02% 66.98% 3.11% 34.52% 29.35% 377 28.42% 71.58% 3.14% 36.97% 31.47%
313 32.94% 67.06% 3.11% 34.55% 29.39% 378 28.35% 71.65% 3.14% 37.01% 31.50%
314 32.87% 67.13% 3.11% 34.58% 29.43% 379 28.28% 71.72% 3.14% 37.04% 31.54%
315 32.79% 67.21% 3.11% 34.62% 29.47% 380 28.23% 71.77% 3.14% 37.08% 31.56%
316 32.70% 67.30% 3.12% 34.68% 29.50% 381 28.15% 71.85% 3.14% 37.12% 31.59%
317 32.63% 67.37% 3.12% 34.72% 29.53% 382 28.07% 71.93% 3.14% 37.17% 31.62%
318 32.56% 67.44% 3.12% 34.76% 29.57% 383 28.01% 71.99% 3.14% 37.20% 31.65%
319 32.49% 67.51% 3.12% 34.80% 29.60% 384 27.94% 72.06% 3.14% 37.24% 31.68%
320 32.41% 67.59% 3.12% 34.84% 29.63% 385 27.88% 72.12% 3.14% 37.28% 31.70%
321 32.33% 67.67% 3.12% 34.88% 29.67% 386 27.80% 72.20% 3.14% 37.32% 31.73%
322 32.27% 67.73% 3.12% 34.91% 29.70% 387 27.73% 72.27% 3.14% 37.36% 31.77%
323 32.19% 67.81% 3.12% 34.94% 29.74% 388 27.66% 72.34% 3.14% 37.39% 31.80%
324 32.13% 67.87% 3.12% 34.98% 29.77% 389 27.61% 72.39% 3.14% 37.42% 31.82%
325 32.04% 67.96% 3.12% 35.02% 29.82% 390 27.56% 72.44% 3.14% 37.45% 31.85%
326 31.96% 68.04% 3.12% 35.07% 29.85% 391 27.51% 72.49% 3.14% 37.48% 31.87%
327 31.88% 68.12% 3.12% 35.10% 29.89% 392 27.45% 72.55% 3.15% 37.50% 31.90%
328 31.81% 68.19% 3.12% 35.15% 29.92% 393 27.38% 72.62% 3.15% 37.55% 31.93%
329 31.73% 68.27% 3.12% 35.19% 29.95% 394 27.32% 72.68% 3.15% 37.58% 31.95%
330 31.66% 68.35% 3.12% 35.24% 29.99% 395 27.25% 72.75% 3.15% 37.62% 31.98%
331 31.58% 68.43% 3.12% 35.28% 30.02% 396 27.20% 72.81% 3.15% 37.65% 32.01%
332 31.50% 68.50% 3.12% 35.32% 30.06% 397 27.14% 72.86% 3.15% 37.68% 32.03%
333 31.44% 68.57% 3.12% 35.35% 30.09% 398 27.08% 72.92% 3.15% 37.71% 32.06%
334 31.37% 68.63% 3.12% 35.38% 30.13% 399 27.01% 73.00% 3.15% 37.77% 32.08%
335 31.30% 68.70% 3.12% 35.42% 30.16% 400 26.95% 73.05% 3.15% 37.80% 32.10%
336 31.23% 68.77% 3.12% 35.46% 30.19% 401 26.90% 73.10% 3.15% 37.83% 32.12%
337 31.16% 68.84% 3.12% 35.49% 30.22% 402 26.85% 73.15% 3.15% 37.86% 32.15%
338 31.08% 68.93% 3.13% 35.54% 30.26% 403 26.80% 73.20% 3.15% 37.89% 32.16%
339 31.00% 69.01% 3.13% 35.58% 30.30% 404 26.73% 73.27% 3.15% 37.93% 32.19%
340 30.92% 69.08% 3.13% 35.62% 30.34% 405 26.69% 73.31% 3.15% 37.96% 32.21%
341 30.85% 69.15% 3.13% 35.66% 30.36% 406 26.64% 73.37% 3.15% 37.98% 32.24%
342 30.79% 69.21% 3.13% 35.70% 30.39% 407 26.57% 73.43% 3.15% 38.02% 32.26%
343 30.71% 69.29% 3.13% 35.75% 30.42% 408 26.51% 73.49% 3.15% 38.05% 32.28%
262
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 409 26.46% 73.54% 3.15% 38.08% 32.31% 474 23.08% 76.92% 3.15% 39.92% 33.84%
410 26.40% 73.60% 3.15% 38.12% 32.34% 475 23.04% 76.97% 3.15% 39.95% 33.87%
411 26.35% 73.65% 3.15% 38.14% 32.37% 476 23.00% 77.00% 3.15% 39.97% 33.88%
412 26.29% 73.72% 3.15% 38.17% 32.40% 477 22.95% 77.05% 3.15% 40.00% 33.90%
413 26.22% 73.78% 3.15% 38.20% 32.43% 478 22.90% 77.10% 3.15% 40.03% 33.93%
414 26.15% 73.85% 3.15% 38.24% 32.46% 479 22.87% 77.14% 3.15% 40.04% 33.94%
415 26.10% 73.90% 3.15% 38.27% 32.48% 480 22.82% 77.18% 3.15% 40.07% 33.96%
416 26.05% 73.95% 3.15% 38.29% 32.51% 481 22.76% 77.24% 3.15% 40.10% 33.99%
417 26.00% 74.00% 3.15% 38.32% 32.53% 482 22.71% 77.29% 3.15% 40.14% 34.00%
418 25.94% 74.06% 3.15% 38.37% 32.55% 483 22.67% 77.34% 3.15% 40.16% 34.03%
419 25.89% 74.11% 3.15% 38.39% 32.58% 484 22.62% 77.38% 3.15% 40.18% 34.05%
420 25.83% 74.17% 3.15% 38.42% 32.60% 485 22.57% 77.43% 3.15% 40.21% 34.07%
421 25.78% 74.23% 3.15% 38.47% 32.61% 486 22.51% 77.49% 3.15% 40.24% 34.10%
422 25.72% 74.28% 3.15% 38.50% 32.63% 487 22.46% 77.54% 3.15% 40.27% 34.12%
423 25.67% 74.33% 3.15% 38.52% 32.66% 488 22.42% 77.58% 3.15% 40.30% 34.13%
424 25.61% 74.39% 3.15% 38.56% 32.68% 489 22.36% 77.64% 3.15% 40.32% 34.16%
425 25.57% 74.44% 3.15% 38.58% 32.71% 490 22.32% 77.68% 3.15% 40.35% 34.18%
426 25.52% 74.48% 3.15% 38.61% 32.72% 491 22.27% 77.73% 3.15% 40.37% 34.20%
427 25.47% 74.53% 3.15% 38.64% 32.75% 492 22.22% 77.78% 3.15% 40.40% 34.23%
428 25.41% 74.59% 3.15% 38.66% 32.78% 493 22.17% 77.83% 3.15% 40.42% 34.26%
429 25.35% 74.65% 3.15% 38.69% 32.81% 494 22.13% 77.87% 3.15% 40.44% 34.28%
430 25.29% 74.71% 3.15% 38.72% 32.84% 495 22.08% 77.92% 3.15% 40.47% 34.31%
431 25.25% 74.76% 3.15% 38.75% 32.85% 496 22.04% 77.96% 3.15% 40.49% 34.33%
432 25.18% 74.82% 3.15% 38.78% 32.89% 497 21.98% 78.02% 3.15% 40.51% 34.36%
433 25.14% 74.86% 3.15% 38.80% 32.91% 498 21.94% 78.06% 3.15% 40.53% 34.38%
434 25.10% 74.90% 3.15% 38.82% 32.93% 499 21.88% 78.12% 3.15% 40.56% 34.41%
435 25.04% 74.96% 3.15% 38.86% 32.96% 500 21.83% 78.17% 3.15% 40.59% 34.43%
436 24.99% 75.01% 3.15% 38.89% 32.97% 501 21.79% 78.21% 3.15% 40.62% 34.45%
437 24.93% 75.07% 3.15% 38.92% 33.01% 502 21.74% 78.26% 3.15% 40.65% 34.47%
438 24.88% 75.12% 3.15% 38.94% 33.03% 503 21.69% 78.31% 3.15% 40.67% 34.49%
439 24.82% 75.18% 3.15% 38.98% 33.05% 504 21.64% 78.36% 3.15% 40.69% 34.52%
440 24.77% 75.23% 3.15% 39.00% 33.08% 505 21.60% 78.40% 3.15% 40.72% 34.53%
441 24.72% 75.28% 3.15% 39.03% 33.11% 506 21.57% 78.43% 3.15% 40.73% 34.55%
442 24.66% 75.34% 3.15% 39.07% 33.13% 507 21.53% 78.47% 3.15% 40.75% 34.57%
443 24.61% 75.39% 3.15% 39.10% 33.14% 508 21.48% 78.52% 3.15% 40.77% 34.60%
444 24.56% 75.44% 3.15% 39.13% 33.17% 509 21.43% 78.57% 3.15% 40.80% 34.62%
445 24.51% 75.49% 3.15% 39.16% 33.18% 510 21.38% 78.62% 3.15% 40.82% 34.65%
446 24.46% 75.54% 3.15% 39.19% 33.20% 511 21.35% 78.66% 3.15% 40.84% 34.66%
447 24.41% 75.59% 3.15% 39.22% 33.22% 512 21.30% 78.70% 3.15% 40.86% 34.69%
448 24.38% 75.63% 3.15% 39.24% 33.24% 513 21.25% 78.75% 3.15% 40.89% 34.71%
449 24.32% 75.68% 3.15% 39.27% 33.26% 514 21.21% 78.79% 3.15% 40.91% 34.74%
450 24.27% 75.73% 3.15% 39.30% 33.28% 515 21.17% 78.83% 3.15% 40.93% 34.75%
451 24.22% 75.78% 3.15% 39.33% 33.31% 516 21.12% 78.88% 3.15% 40.96% 34.77%
452 24.17% 75.83% 3.15% 39.35% 33.33% 517 21.07% 78.93% 3.15% 40.98% 34.80%
453 24.11% 75.89% 3.15% 39.39% 33.35% 518 21.03% 78.97% 3.15% 41.01% 34.82%
454 24.07% 75.94% 3.15% 39.41% 33.38% 519 20.99% 79.01% 3.15% 41.03% 34.83%
455 24.00% 76.00% 3.15% 39.44% 33.41% 520 20.95% 79.05% 3.15% 41.05% 34.85%
456 23.96% 76.05% 3.15% 39.47% 33.43% 521 20.90% 79.10% 3.15% 41.08% 34.88%
457 23.92% 76.08% 3.15% 39.49% 33.45% 522 20.86% 79.14% 3.15% 41.09% 34.90%
458 23.89% 76.12% 3.15% 39.50% 33.47% 523 20.82% 79.18% 3.15% 41.12% 34.91%
459 23.85% 76.16% 3.15% 39.53% 33.48% 524 20.79% 79.21% 3.15% 41.14% 34.93%
460 23.78% 76.22% 3.15% 39.56% 33.51% 525 20.74% 79.26% 3.15% 41.16% 34.95%
461 23.73% 76.27% 3.15% 39.59% 33.53% 526 20.70% 79.30% 3.15% 41.18% 34.97%
462 23.68% 76.32% 3.15% 39.61% 33.56% 527 20.66% 79.34% 3.15% 41.20% 34.99%
463 23.63% 76.37% 3.15% 39.64% 33.59% 528 20.62% 79.38% 3.15% 41.23% 35.01%
464 23.57% 76.43% 3.15% 39.67% 33.61% 529 20.58% 79.42% 3.15% 41.25% 35.02%
465 23.52% 76.48% 3.15% 39.71% 33.63% 530 20.54% 79.47% 3.15% 41.28% 35.04%
466 23.47% 76.53% 3.15% 39.73% 33.65% 531 20.50% 79.50% 3.15% 41.29% 35.06%
467 23.42% 76.58% 3.15% 39.76% 33.68% 532 20.46% 79.54% 3.15% 41.31% 35.07%
468 23.36% 76.64% 3.15% 39.78% 33.71% 533 20.44% 79.57% 3.15% 41.33% 35.09%
469 23.32% 76.68% 3.15% 39.80% 33.73% 534 20.40% 79.60% 3.15% 41.35% 35.11%
470 23.28% 76.73% 3.15% 39.83% 33.75% 535 20.35% 79.65% 3.15% 41.37% 35.13%
471 23.23% 76.78% 3.15% 39.85% 33.77% 536 20.31% 79.69% 3.15% 41.40% 35.14%
472 23.16% 76.84% 3.15% 39.89% 33.80% 537 20.27% 79.73% 3.15% 41.42% 35.16%
473 23.13% 76.87% 3.15% 39.90% 33.82% 538 20.23% 79.77% 3.15% 41.44% 35.18%
263
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 539 20.20% 79.80% 3.15% 41.46% 35.19% 604 17.81% 82.19% 3.15% 42.73% 36.31%
540 20.15% 79.85% 3.15% 41.50% 35.20% 605 17.77% 82.23% 3.15% 42.75% 36.33%
541 20.11% 79.89% 3.15% 41.53% 35.22% 606 17.74% 82.27% 3.15% 42.77% 36.35%
542 20.07% 79.93% 3.15% 41.54% 35.24% 607 17.71% 82.30% 3.15% 42.79% 36.36%
543 20.04% 79.96% 3.15% 41.56% 35.25% 608 17.66% 82.34% 3.15% 42.81% 36.38%
544 20.00% 80.00% 3.15% 41.59% 35.27% 609 17.62% 82.38% 3.15% 42.83% 36.40%
545 19.96% 80.04% 3.15% 41.60% 35.29% 610 17.59% 82.41% 3.15% 42.85% 36.42%
546 19.92% 80.08% 3.15% 41.63% 35.30% 611 17.55% 82.45% 3.15% 42.87% 36.43%
547 19.88% 80.12% 3.15% 41.65% 35.32% 612 17.52% 82.48% 3.15% 42.88% 36.45%
548 19.84% 80.16% 3.15% 41.67% 35.34% 613 17.50% 82.51% 3.15% 42.90% 36.46%
549 19.80% 80.20% 3.15% 41.69% 35.36% 614 17.46% 82.54% 3.15% 42.92% 36.48%
550 19.76% 80.24% 3.15% 41.71% 35.38% 615 17.42% 82.58% 3.15% 42.94% 36.50%
551 19.72% 80.28% 3.15% 41.73% 35.40% 616 17.38% 82.63% 3.15% 42.97% 36.51%
552 19.68% 80.32% 3.15% 41.74% 35.42% 617 17.34% 82.66% 3.15% 42.99% 36.52%
553 19.64% 80.36% 3.15% 41.76% 35.45% 618 17.30% 82.70% 3.15% 43.01% 36.54%
554 19.61% 80.39% 3.15% 41.78% 35.46% 619 17.27% 82.73% 3.15% 43.02% 36.55%
555 19.57% 80.43% 3.15% 41.80% 35.48% 620 17.24% 82.76% 3.15% 43.04% 36.57%
556 19.54% 80.46% 3.15% 41.81% 35.50% 621 17.20% 82.80% 3.15% 43.06% 36.60%
557 19.50% 80.50% 3.15% 41.83% 35.52% 622 17.16% 82.84% 3.15% 43.08% 36.62%
558 19.46% 80.54% 3.15% 41.85% 35.54% 623 17.12% 82.88% 3.15% 43.09% 36.63%
559 19.43% 80.57% 3.15% 41.87% 35.55% 624 17.09% 82.91% 3.15% 43.12% 36.65%
560 19.40% 80.61% 3.15% 41.89% 35.57% 625 17.06% 82.95% 3.15% 43.13% 36.66%
561 19.35% 80.65% 3.15% 41.92% 35.59% 626 17.02% 82.98% 3.15% 43.15% 36.68%
562 19.30% 80.70% 3.15% 41.94% 35.61% 627 17.00% 83.00% 3.15% 43.16% 36.70%
563 19.26% 80.74% 3.15% 41.96% 35.63% 628 16.96% 83.04% 3.15% 43.18% 36.71%
564 19.23% 80.77% 3.15% 41.98% 35.64% 629 16.94% 83.06% 3.15% 43.19% 36.72%
565 19.19% 80.81% 3.15% 42.00% 35.66% 630 16.92% 83.09% 3.15% 43.21% 36.73%
566 19.16% 80.84% 3.15% 42.01% 35.68% 631 16.88% 83.12% 3.15% 43.23% 36.74%
567 19.12% 80.88% 3.15% 42.03% 35.70% 632 16.85% 83.16% 3.15% 43.25% 36.76%
568 19.08% 80.92% 3.15% 42.06% 35.71% 633 16.82% 83.18% 3.15% 43.26% 36.77%
569 19.04% 80.96% 3.15% 42.08% 35.73% 634 16.79% 83.21% 3.15% 43.27% 36.78%
570 19.00% 81.00% 3.15% 42.10% 35.75% 635 16.76% 83.24% 3.15% 43.30% 36.80%
571 18.97% 81.03% 3.15% 42.12% 35.76% 636 16.72% 83.28% 3.15% 43.31% 36.82%
572 18.93% 81.07% 3.15% 42.14% 35.78% 637 16.69% 83.31% 3.15% 43.33% 36.83%
573 18.89% 81.11% 3.15% 42.16% 35.80% 638 16.67% 83.33% 3.15% 43.34% 36.84%
574 18.86% 81.15% 3.15% 42.18% 35.82% 639 16.64% 83.36% 3.15% 43.36% 36.85%
575 18.82% 81.18% 3.15% 42.19% 35.83% 640 16.61% 83.39% 3.15% 43.38% 36.87%
576 18.80% 81.20% 3.15% 42.21% 35.85% 641 16.58% 83.42% 3.15% 43.40% 36.88%
577 18.76% 81.25% 3.15% 42.23% 35.87% 642 16.55% 83.45% 3.15% 43.42% 36.89%
578 18.71% 81.29% 3.15% 42.26% 35.89% 643 16.51% 83.49% 3.15% 43.44% 36.90%
579 18.68% 81.33% 3.15% 42.28% 35.90% 644 16.48% 83.52% 3.15% 43.46% 36.92%
580 18.63% 81.37% 3.15% 42.30% 35.92% 645 16.45% 83.55% 3.15% 43.47% 36.93%
581 18.60% 81.40% 3.15% 42.32% 35.94% 646 16.41% 83.59% 3.15% 43.49% 36.95%
582 18.56% 81.44% 3.15% 42.34% 35.95% 647 16.39% 83.61% 3.15% 43.50% 36.96%
583 18.53% 81.47% 3.15% 42.35% 35.97% 648 16.36% 83.64% 3.15% 43.51% 36.98%
584 18.49% 81.51% 3.15% 42.37% 35.99% 649 16.33% 83.67% 3.15% 43.53% 36.99%
585 18.46% 81.54% 3.15% 42.38% 36.01% 650 16.29% 83.71% 3.15% 43.55% 37.01%
586 18.43% 81.58% 3.15% 42.40% 36.03% 651 16.27% 83.73% 3.15% 43.56% 37.03%
587 18.40% 81.60% 3.15% 42.41% 36.04% 652 16.24% 83.76% 3.15% 43.57% 37.04%
588 18.36% 81.64% 3.15% 42.43% 36.07% 653 16.22% 83.79% 3.15% 43.58% 37.06%
589 18.32% 81.68% 3.15% 42.45% 36.08% 654 16.19% 83.81% 3.15% 43.59% 37.07%
590 18.28% 81.72% 3.15% 42.46% 36.11% 655 16.16% 83.84% 3.15% 43.61% 37.08%
591 18.25% 81.75% 3.15% 42.49% 36.11% 656 16.14% 83.86% 3.15% 43.62% 37.09%
592 18.21% 81.79% 3.15% 42.51% 36.13% 657 16.11% 83.89% 3.15% 43.64% 37.10%
593 18.18% 81.82% 3.15% 42.52% 36.15% 658 16.08% 83.92% 3.15% 43.66% 37.11%
594 18.14% 81.86% 3.15% 42.54% 36.17% 659 16.05% 83.95% 3.15% 43.67% 37.13%
595 18.10% 81.91% 3.15% 42.56% 36.19% 660 16.01% 84.00% 3.15% 43.69% 37.15%
596 18.07% 81.93% 3.15% 42.58% 36.20% 661 15.97% 84.03% 3.15% 43.71% 37.17%
597 18.03% 81.97% 3.15% 42.60% 36.22% 662 15.94% 84.06% 3.15% 43.72% 37.18%
598 18.01% 81.99% 3.15% 42.61% 36.23% 663 15.93% 84.07% 3.15% 43.73% 37.19%
599 17.98% 82.02% 3.15% 42.63% 36.24% 664 15.89% 84.11% 3.15% 43.75% 37.21%
600 17.94% 82.06% 3.15% 42.65% 36.26% 665 15.87% 84.13% 3.15% 43.76% 37.22%
601 17.91% 82.09% 3.15% 42.67% 36.27% 666 15.84% 84.16% 3.15% 43.78% 37.24%
602 17.87% 82.13% 3.15% 42.69% 36.29% 667 15.80% 84.20% 3.15% 43.79% 37.25%
603 17.84% 82.16% 3.15% 42.71% 36.30% 668 15.77% 84.23% 3.15% 43.81% 37.27%
264
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 669 15.73% 84.27% 3.15% 43.83% 37.29% 734 14.06% 85.94% 3.15% 44.70% 38.09%
670 15.70% 84.30% 3.15% 43.84% 37.31% 735 14.04% 85.96% 3.15% 44.71% 38.10%
671 15.67% 84.33% 3.15% 43.85% 37.33% 736 14.02% 85.98% 3.15% 44.73% 38.11%
672 15.64% 84.36% 3.15% 43.87% 37.34% 737 13.99% 86.01% 3.15% 44.74% 38.13%
673 15.61% 84.39% 3.15% 43.89% 37.36% 738 13.96% 86.04% 3.15% 44.75% 38.14%
674 15.58% 84.42% 3.15% 43.90% 37.37% 739 13.93% 86.07% 3.15% 44.77% 38.16%
675 15.56% 84.44% 3.15% 43.91% 37.38% 740 13.90% 86.10% 3.15% 44.77% 38.18%
676 15.53% 84.47% 3.15% 43.93% 37.40% 741 13.88% 86.13% 3.15% 44.79% 38.19%
677 15.49% 84.51% 3.15% 43.95% 37.41% 742 13.85% 86.16% 3.15% 44.80% 38.20%
678 15.47% 84.53% 3.15% 43.96% 37.42% 743 13.82% 86.18% 3.15% 44.82% 38.21%
679 15.44% 84.56% 3.15% 43.97% 37.44% 744 13.80% 86.20% 3.15% 44.83% 38.22%
680 15.42% 84.58% 3.15% 43.98% 37.45% 745 13.77% 86.23% 3.15% 44.85% 38.23%
681 15.39% 84.61% 3.15% 44.00% 37.46% 746 13.74% 86.26% 3.15% 44.86% 38.25%
682 15.37% 84.64% 3.15% 44.01% 37.48% 747 13.72% 86.28% 3.15% 44.88% 38.26%
683 15.33% 84.67% 3.15% 44.03% 37.49% 748 13.70% 86.30% 3.15% 44.88% 38.27%
684 15.31% 84.70% 3.15% 44.04% 37.51% 749 13.67% 86.33% 3.15% 44.90% 38.28%
685 15.27% 84.73% 3.15% 44.06% 37.52% 750 13.65% 86.35% 3.15% 44.92% 38.29%
686 15.24% 84.76% 3.15% 44.08% 37.53% 751 13.62% 86.38% 3.15% 44.93% 38.30%
687 15.22% 84.78% 3.15% 44.09% 37.55% 752 13.59% 86.41% 3.15% 44.94% 38.32%
688 15.19% 84.81% 3.15% 44.09% 37.56% 753 13.56% 86.44% 3.15% 44.96% 38.33%
689 15.17% 84.83% 3.15% 44.11% 37.57% 754 13.54% 86.46% 3.15% 44.97% 38.34%
690 15.15% 84.86% 3.15% 44.12% 37.59% 755 13.51% 86.49% 3.15% 44.98% 38.36%
691 15.11% 84.89% 3.15% 44.14% 37.61% 756 13.48% 86.52% 3.15% 45.01% 38.37%
692 15.08% 84.92% 3.15% 44.16% 37.62% 757 13.44% 86.56% 3.15% 45.02% 38.39%
693 15.05% 84.95% 3.15% 44.17% 37.63% 758 13.42% 86.58% 3.15% 45.03% 38.40%
694 15.03% 84.97% 3.15% 44.18% 37.63% 759 13.40% 86.60% 3.15% 45.04% 38.41%
695 15.01% 84.99% 3.15% 44.20% 37.64% 760 13.37% 86.63% 3.15% 45.06% 38.43%
696 14.99% 85.01% 3.15% 44.21% 37.65% 761 13.35% 86.65% 3.15% 45.07% 38.44%
697 14.96% 85.04% 3.15% 44.23% 37.66% 762 13.32% 86.68% 3.15% 45.08% 38.45%
698 14.95% 85.05% 3.15% 44.23% 37.67% 763 13.29% 86.71% 3.15% 45.10% 38.46%
699 14.91% 85.09% 3.15% 44.26% 37.68% 764 13.28% 86.72% 3.15% 45.10% 38.47%
700 14.89% 85.11% 3.15% 44.27% 37.69% 765 13.26% 86.75% 3.15% 45.11% 38.48%
701 14.86% 85.14% 3.15% 44.29% 37.70% 766 13.22% 86.78% 3.15% 45.13% 38.50%
702 14.83% 85.17% 3.15% 44.30% 37.71% 767 13.20% 86.80% 3.15% 45.14% 38.51%
703 14.82% 85.19% 3.15% 44.32% 37.72% 768 13.18% 86.82% 3.15% 45.15% 38.52%
704 14.80% 85.20% 3.15% 44.32% 37.73% 769 13.15% 86.85% 3.15% 45.17% 38.53%
705 14.78% 85.22% 3.15% 44.33% 37.74% 770 13.13% 86.87% 3.15% 45.19% 38.54%
706 14.75% 85.25% 3.15% 44.34% 37.76% 771 13.10% 86.90% 3.15% 45.20% 38.55%
707 14.73% 85.28% 3.15% 44.36% 37.77% 772 13.08% 86.92% 3.15% 45.21% 38.56%
708 14.71% 85.30% 3.15% 44.37% 37.78% 773 13.06% 86.94% 3.15% 45.23% 38.57%
709 14.68% 85.32% 3.15% 44.38% 37.79% 774 13.03% 86.97% 3.15% 45.24% 38.58%
710 14.66% 85.34% 3.15% 44.39% 37.80% 775 13.01% 86.99% 3.15% 45.25% 38.59%
711 14.63% 85.37% 3.15% 44.41% 37.82% 776 12.99% 87.02% 3.15% 45.26% 38.61%
712 14.60% 85.40% 3.15% 44.42% 37.83% 777 12.97% 87.03% 3.15% 45.27% 38.61%
713 14.58% 85.42% 3.15% 44.44% 37.84% 778 12.94% 87.06% 3.15% 45.29% 38.63%
714 14.55% 85.45% 3.15% 44.46% 37.85% 779 12.92% 87.08% 3.15% 45.29% 38.64%
715 14.52% 85.48% 3.15% 44.47% 37.86% 780 12.90% 87.10% 3.15% 45.31% 38.64%
716 14.50% 85.50% 3.15% 44.48% 37.87% 781 12.88% 87.12% 3.15% 45.31% 38.65%
717 14.48% 85.52% 3.15% 44.49% 37.89% 782 12.87% 87.13% 3.15% 45.32% 38.66%
718 14.46% 85.54% 3.15% 44.50% 37.90% 783 12.85% 87.15% 3.15% 45.33% 38.67%
719 14.43% 85.57% 3.15% 44.51% 37.91% 784 12.82% 87.18% 3.15% 45.36% 38.68%
720 14.40% 85.60% 3.15% 44.53% 37.92% 785 12.80% 87.20% 3.15% 45.37% 38.69%
721 14.37% 85.63% 3.15% 44.55% 37.94% 786 12.78% 87.22% 3.15% 45.38% 38.70%
722 14.35% 85.65% 3.15% 44.56% 37.95% 787 12.75% 87.25% 3.15% 45.39% 38.71%
723 14.33% 85.67% 3.15% 44.57% 37.96% 788 12.73% 87.27% 3.15% 45.40% 38.72%
724 14.30% 85.70% 3.15% 44.59% 37.97% 789 12.71% 87.29% 3.15% 45.41% 38.73%
725 14.27% 85.73% 3.15% 44.60% 37.98% 790 12.68% 87.32% 3.15% 45.43% 38.74%
726 14.24% 85.76% 3.15% 44.61% 38.00% 791 12.66% 87.34% 3.15% 45.44% 38.75%
727 14.22% 85.78% 3.15% 44.62% 38.01% 792 12.64% 87.36% 3.15% 45.45% 38.76%
728 14.20% 85.80% 3.15% 44.64% 38.02% 793 12.62% 87.38% 3.15% 45.46% 38.77%
729 14.18% 85.82% 3.15% 44.64% 38.03% 794 12.60% 87.40% 3.15% 45.47% 38.78%
730 14.16% 85.85% 3.15% 44.66% 38.04% 795 12.57% 87.43% 3.15% 45.48% 38.80%
731 14.13% 85.87% 3.15% 44.67% 38.05% 796 12.55% 87.45% 3.15% 45.50% 38.81%
732 14.11% 85.89% 3.15% 44.68% 38.06% 797 12.53% 87.47% 3.15% 45.50% 38.82%
733 14.09% 85.91% 3.15% 44.69% 38.08% 798 12.52% 87.48% 3.15% 45.51% 38.83%
265
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 799 12.50% 87.50% 3.15% 45.52% 38.83% 864 11.17% 88.83% 3.15% 46.18% 39.50%
800 12.48% 87.52% 3.15% 45.53% 38.85% 865 11.16% 88.85% 3.15% 46.19% 39.51%
801 12.46% 87.54% 3.15% 45.53% 38.85% 866 11.14% 88.86% 3.15% 46.20% 39.52%
802 12.45% 87.55% 3.15% 45.54% 38.86% 867 11.11% 88.89% 3.15% 46.21% 39.53%
803 12.42% 87.58% 3.15% 45.56% 38.88% 868 11.10% 88.91% 3.15% 46.22% 39.53%
804 12.39% 87.61% 3.15% 45.57% 38.89% 869 11.08% 88.92% 3.15% 46.23% 39.54%
805 12.38% 87.63% 3.15% 45.58% 38.90% 870 11.06% 88.94% 3.15% 46.24% 39.55%
806 12.35% 87.66% 3.15% 45.59% 38.91% 871 11.04% 88.96% 3.15% 46.25% 39.56%
807 12.32% 87.68% 3.15% 45.61% 38.93% 872 11.02% 88.99% 3.15% 46.26% 39.57%
808 12.29% 87.71% 3.15% 45.62% 38.95% 873 10.99% 89.01% 3.15% 46.27% 39.59%
809 12.26% 87.74% 3.15% 45.63% 38.96% 874 10.97% 89.03% 3.15% 46.28% 39.60%
810 12.24% 87.76% 3.15% 45.64% 38.97% 875 10.95% 89.05% 3.15% 46.29% 39.61%
811 12.21% 87.79% 3.15% 45.66% 38.98% 876 10.93% 89.07% 3.15% 46.31% 39.62%
812 12.19% 87.81% 3.15% 45.67% 38.99% 877 10.91% 89.09% 3.15% 46.31% 39.63%
813 12.16% 87.84% 3.15% 45.68% 39.01% 878 10.90% 89.11% 3.15% 46.32% 39.64%
814 12.15% 87.85% 3.15% 45.69% 39.02% 879 10.88% 89.12% 3.15% 46.33% 39.65%
815 12.12% 87.88% 3.15% 45.70% 39.03% 880 10.86% 89.14% 3.15% 46.34% 39.65%
816 12.11% 87.89% 3.15% 45.70% 39.04% 881 10.84% 89.16% 3.15% 46.34% 39.67%
817 12.09% 87.91% 3.15% 45.72% 39.05% 882 10.82% 89.18% 3.15% 46.35% 39.68%
818 12.07% 87.93% 3.15% 45.72% 39.06% 883 10.81% 89.19% 3.15% 46.36% 39.69%
819 12.05% 87.95% 3.15% 45.73% 39.07% 884 10.78% 89.22% 3.15% 46.37% 39.70%
820 12.03% 87.97% 3.15% 45.74% 39.08% 885 10.76% 89.24% 3.15% 46.38% 39.71%
821 12.02% 87.98% 3.15% 45.75% 39.08% 886 10.76% 89.25% 3.15% 46.39% 39.71%
822 12.00% 88.01% 3.15% 45.76% 39.10% 887 10.74% 89.27% 3.15% 46.40% 39.72%
823 11.98% 88.02% 3.15% 45.77% 39.10% 888 10.72% 89.28% 3.15% 46.41% 39.72%
824 11.96% 88.04% 3.15% 45.78% 39.11% 889 10.70% 89.30% 3.15% 46.42% 39.73%
825 11.93% 88.07% 3.15% 45.79% 39.13% 890 10.69% 89.31% 3.15% 46.42% 39.74%
826 11.91% 88.09% 3.15% 45.80% 39.14% 891 10.67% 89.33% 3.15% 46.43% 39.75%
827 11.88% 88.12% 3.15% 45.82% 39.15% 892 10.66% 89.34% 3.15% 46.44% 39.75%
828 11.86% 88.14% 3.15% 45.83% 39.16% 893 10.64% 89.36% 3.15% 46.45% 39.76%
829 11.85% 88.15% 3.15% 45.84% 39.17% 894 10.63% 89.37% 3.15% 46.46% 39.77%
830 11.83% 88.17% 3.15% 45.85% 39.18% 895 10.62% 89.38% 3.15% 46.47% 39.77%
831 11.80% 88.20% 3.15% 45.86% 39.19% 896 10.61% 89.40% 3.15% 46.47% 39.78%
832 11.79% 88.21% 3.15% 45.87% 39.20% 897 10.59% 89.41% 3.15% 46.48% 39.78%
833 11.77% 88.23% 3.15% 45.88% 39.20% 898 10.58% 89.42% 3.15% 46.49% 39.79%
834 11.75% 88.25% 3.15% 45.89% 39.21% 899 10.56% 89.44% 3.15% 46.49% 39.80%
835 11.73% 88.27% 3.15% 45.90% 39.22% 900 10.53% 89.47% 3.15% 46.51% 39.81%
836 11.70% 88.30% 3.15% 45.92% 39.23% 901 10.51% 89.49% 3.15% 46.52% 39.82%
837 11.68% 88.32% 3.15% 45.92% 39.24% 902 10.49% 89.51% 3.15% 46.53% 39.83%
838 11.66% 88.34% 3.15% 45.94% 39.25% 903 10.47% 89.53% 3.15% 46.54% 39.84%
839 11.64% 88.36% 3.15% 45.95% 39.27% 904 10.46% 89.54% 3.15% 46.54% 39.85%
840 11.62% 88.38% 3.15% 45.96% 39.28% 905 10.44% 89.56% 3.15% 46.55% 39.86%
841 11.59% 88.41% 3.15% 45.97% 39.29% 906 10.42% 89.58% 3.15% 46.56% 39.87%
842 11.58% 88.42% 3.15% 45.98% 39.29% 907 10.40% 89.60% 3.15% 46.57% 39.88%
843 11.56% 88.44% 3.15% 45.99% 39.31% 908 10.38% 89.62% 3.15% 46.58% 39.89%
844 11.54% 88.47% 3.15% 45.99% 39.32% 909 10.36% 89.64% 3.15% 46.59% 39.90%
845 11.52% 88.48% 3.15% 46.00% 39.33% 910 10.34% 89.66% 3.15% 46.61% 39.90%
846 11.50% 88.51% 3.15% 46.02% 39.34% 911 10.33% 89.67% 3.15% 46.61% 39.91%
847 11.48% 88.52% 3.15% 46.03% 39.35% 912 10.32% 89.68% 3.15% 46.62% 39.92%
848 11.46% 88.54% 3.15% 46.04% 39.36% 913 10.30% 89.70% 3.15% 46.62% 39.93%
849 11.44% 88.56% 3.15% 46.04% 39.37% 914 10.29% 89.72% 3.15% 46.63% 39.94%
850 11.43% 88.57% 3.15% 46.05% 39.37% 915 10.27% 89.73% 3.15% 46.64% 39.94%
851 11.41% 88.59% 3.15% 46.06% 39.38% 916 10.26% 89.75% 3.15% 46.65% 39.95%
852 11.39% 88.61% 3.15% 46.07% 39.39% 917 10.24% 89.76% 3.15% 46.65% 39.96%
853 11.38% 88.62% 3.15% 46.08% 39.39% 918 10.22% 89.78% 3.15% 46.66% 39.97%
854 11.37% 88.63% 3.15% 46.08% 39.40% 919 10.21% 89.79% 3.15% 46.67% 39.98%
855 11.35% 88.65% 3.15% 46.10% 39.41% 920 10.20% 89.81% 3.15% 46.67% 39.98%
856 11.33% 88.67% 3.15% 46.10% 39.42% 921 10.19% 89.82% 3.15% 46.68% 39.99%
857 11.32% 88.69% 3.15% 46.11% 39.43% 922 10.17% 89.84% 3.15% 46.69% 39.99%
858 11.29% 88.71% 3.15% 46.12% 39.44% 923 10.15% 89.85% 3.15% 46.70% 40.00%
859 11.28% 88.72% 3.15% 46.12% 39.45% 924 10.13% 89.87% 3.15% 46.71% 40.02%
860 11.26% 88.75% 3.15% 46.14% 39.46% 925 10.11% 89.89% 3.15% 46.72% 40.03%
861 11.24% 88.76% 3.15% 46.15% 39.47% 926 10.09% 89.91% 3.15% 46.73% 40.03%
862 11.21% 88.79% 3.15% 46.16% 39.48% 927 10.08% 89.92% 3.15% 46.73% 40.04%
863 11.19% 88.81% 3.15% 46.17% 39.50% 928 10.07% 89.93% 3.15% 46.74% 40.05%
266
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 929 10.05% 89.95% 3.15% 46.74% 40.06% 994 9.06% 90.94% 3.15% 47.19% 40.61%
930 10.04% 89.96% 3.15% 46.75% 40.07% 995 9.05% 90.95% 3.15% 47.19% 40.61%
931 10.03% 89.97% 3.15% 46.75% 40.07% 996 9.03% 90.97% 3.15% 47.20% 40.62%
932 10.01% 89.99% 3.15% 46.76% 40.08% 997 9.01% 90.99% 3.15% 47.21% 40.63%
933 9.99% 90.01% 3.15% 46.76% 40.10% 998 9.00% 91.00% 3.15% 47.22% 40.63%
934 9.97% 90.03% 3.15% 46.77% 40.11% 999 8.99% 91.02% 3.15% 47.22% 40.64%
935 9.95% 90.05% 3.15% 46.78% 40.12% 1000 8.96% 91.04% 3.15% 47.23% 40.65%
936 9.94% 90.06% 3.15% 46.78% 40.13% 1001 8.95% 91.05% 3.15% 47.24% 40.66%
937 9.93% 90.08% 3.15% 46.79% 40.14% 1002 8.94% 91.06% 3.15% 47.25% 40.67%
938 9.91% 90.09% 3.15% 46.80% 40.14% 1003 8.93% 91.07% 3.15% 47.25% 40.68%
939 9.90% 90.10% 3.15% 46.80% 40.15% 1004 8.92% 91.08% 3.15% 47.25% 40.68%
940 9.88% 90.12% 3.15% 46.81% 40.17% 1005 8.90% 91.10% 3.15% 47.26% 40.69%
941 9.86% 90.14% 3.15% 46.82% 40.17% 1006 8.89% 91.11% 3.15% 47.26% 40.70%
942 9.84% 90.16% 3.15% 46.82% 40.19% 1007 8.87% 91.13% 3.15% 47.27% 40.71%
943 9.83% 90.18% 3.15% 46.83% 40.20% 1008 8.86% 91.14% 3.15% 47.28% 40.72%
944 9.80% 90.20% 3.15% 46.84% 40.21% 1009 8.84% 91.16% 3.15% 47.28% 40.72%
945 9.79% 90.21% 3.15% 46.85% 40.21% 1010 8.84% 91.16% 3.15% 47.29% 40.73%
946 9.77% 90.23% 3.15% 46.86% 40.22% 1011 8.82% 91.18% 3.15% 47.29% 40.73%
947 9.75% 90.25% 3.15% 46.87% 40.23% 1012 8.81% 91.19% 3.15% 47.30% 40.74%
948 9.74% 90.27% 3.15% 46.88% 40.24% 1013 8.80% 91.20% 3.15% 47.31% 40.74%
949 9.72% 90.28% 3.15% 46.89% 40.25% 1014 8.79% 91.21% 3.15% 47.32% 40.75%
950 9.70% 90.31% 3.15% 46.90% 40.26% 1015 8.77% 91.23% 3.15% 47.32% 40.76%
951 9.68% 90.32% 3.15% 46.90% 40.27% 1016 8.76% 91.24% 3.15% 47.33% 40.77%
952 9.67% 90.33% 3.15% 46.91% 40.27% 1017 8.74% 91.26% 3.15% 47.34% 40.77%
953 9.65% 90.35% 3.15% 46.92% 40.28% 1018 8.73% 91.27% 3.15% 47.34% 40.78%
954 9.63% 90.37% 3.15% 46.93% 40.29% 1019 8.72% 91.28% 3.15% 47.35% 40.78%
955 9.62% 90.38% 3.15% 46.93% 40.30% 1020 8.71% 91.29% 3.15% 47.35% 40.79%
956 9.61% 90.40% 3.15% 46.94% 40.30% 1021 8.70% 91.30% 3.15% 47.36% 40.80%
957 9.59% 90.41% 3.15% 46.95% 40.31% 1022 8.69% 91.31% 3.15% 47.36% 40.80%
958 9.57% 90.43% 3.15% 46.96% 40.32% 1023 8.68% 91.32% 3.15% 47.36% 40.81%
959 9.56% 90.44% 3.15% 46.96% 40.33% 1024 8.66% 91.34% 3.15% 47.37% 40.82%
960 9.55% 90.45% 3.15% 46.97% 40.33% 1025 8.64% 91.36% 3.15% 47.38% 40.83%
961 9.53% 90.47% 3.15% 46.98% 40.34% 1026 8.63% 91.37% 3.15% 47.38% 40.84%
962 9.52% 90.48% 3.15% 46.98% 40.35% 1027 8.62% 91.38% 3.15% 47.39% 40.84%
963 9.50% 90.50% 3.15% 46.99% 40.36% 1028 8.61% 91.39% 3.15% 47.39% 40.85%
964 9.48% 90.52% 3.15% 47.00% 40.37% 1029 8.60% 91.40% 3.15% 47.40% 40.85%
965 9.47% 90.53% 3.15% 47.00% 40.38% 1030 8.59% 91.41% 3.15% 47.40% 40.86%
966 9.46% 90.54% 3.15% 47.01% 40.39% 1031 8.58% 91.43% 3.15% 47.41% 40.87%
967 9.44% 90.56% 3.15% 47.02% 40.39% 1032 8.56% 91.44% 3.15% 47.42% 40.87%
968 9.42% 90.58% 3.15% 47.03% 40.40% 1033 8.55% 91.45% 3.15% 47.42% 40.88%
969 9.42% 90.58% 3.15% 47.03% 40.40% 1034 8.54% 91.46% 3.15% 47.43% 40.89%
970 9.40% 90.60% 3.15% 47.04% 40.41% 1035 8.53% 91.47% 3.15% 47.43% 40.90%
971 9.39% 90.61% 3.15% 47.04% 40.42% 1036 8.51% 91.49% 3.15% 47.44% 40.90%
972 9.38% 90.62% 3.15% 47.05% 40.43% 1037 8.49% 91.51% 3.15% 47.45% 40.91%
973 9.37% 90.63% 3.15% 47.05% 40.44% 1038 8.49% 91.51% 3.15% 47.45% 40.91%
974 9.35% 90.65% 3.15% 47.06% 40.45% 1039 8.47% 91.53% 3.15% 47.46% 40.92%
975 9.33% 90.67% 3.15% 47.07% 40.46% 1040 8.47% 91.53% 3.15% 47.46% 40.92%
976 9.32% 90.68% 3.15% 47.07% 40.46% 1041 8.45% 91.55% 3.15% 47.47% 40.93%
977 9.30% 90.70% 3.15% 47.08% 40.47% 1042 8.44% 91.56% 3.15% 47.47% 40.94%
978 9.29% 90.71% 3.15% 47.08% 40.48% 1043 8.43% 91.57% 3.15% 47.48% 40.94%
979 9.28% 90.73% 3.15% 47.09% 40.49% 1044 8.42% 91.58% 3.15% 47.48% 40.95%
980 9.26% 90.74% 3.15% 47.10% 40.49% 1045 8.42% 91.58% 3.15% 47.48% 40.95%
981 9.25% 90.75% 3.15% 47.10% 40.50% 1046 8.41% 91.59% 3.15% 47.49% 40.95%
982 9.23% 90.77% 3.15% 47.11% 40.51% 1047 8.40% 91.60% 3.15% 47.50% 40.96%
983 9.21% 90.79% 3.15% 47.12% 40.52% 1048 8.39% 91.61% 3.15% 47.50% 40.97%
984 9.20% 90.80% 3.15% 47.12% 40.53% 1049 8.38% 91.62% 3.15% 47.50% 40.97%
985 9.18% 90.82% 3.15% 47.13% 40.54% 1050 8.36% 91.64% 3.15% 47.51% 40.98%
986 9.17% 90.83% 3.15% 47.13% 40.55% 1051 8.36% 91.64% 3.15% 47.51% 40.98%
987 9.15% 90.85% 3.15% 47.14% 40.56% 1052 8.33% 91.67% 3.15% 47.52% 41.00%
988 9.13% 90.87% 3.15% 47.15% 40.57% 1053 8.32% 91.68% 3.15% 47.52% 41.01%
989 9.12% 90.88% 3.15% 47.15% 40.58% 1054 8.31% 91.70% 3.15% 47.53% 41.01%
990 9.11% 90.89% 3.15% 47.16% 40.59% 1055 8.30% 91.70% 3.15% 47.54% 41.02%
991 9.10% 90.90% 3.15% 47.16% 40.59% 1056 8.28% 91.72% 3.15% 47.54% 41.03%
992 9.09% 90.91% 3.15% 47.17% 40.60% 1057 8.27% 91.73% 3.15% 47.55% 41.03%
993 9.08% 90.93% 3.15% 47.18% 40.60% 1058 8.27% 91.73% 3.15% 47.55% 41.03%
267
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 1059 8.25% 91.75% 3.15% 47.56% 41.04% 1124 7.52% 92.48% 3.15% 47.91% 41.43%
1060 8.24% 91.76% 3.15% 47.57% 41.05% 1125 7.50% 92.50% 3.15% 47.92% 41.43%
1061 8.23% 91.77% 3.15% 47.57% 41.05% 1126 7.49% 92.51% 3.15% 47.92% 41.44%
1062 8.22% 91.78% 3.15% 47.58% 41.05% 1127 7.48% 92.52% 3.15% 47.93% 41.44%
1063 8.21% 91.79% 3.15% 47.58% 41.06% 1128 7.47% 92.54% 3.15% 47.94% 41.45%
1064 8.20% 91.80% 3.15% 47.58% 41.07% 1129 7.45% 92.55% 3.15% 47.95% 41.46%
1065 8.19% 91.81% 3.15% 47.58% 41.07% 1130 7.44% 92.56% 3.15% 47.95% 41.46%
1066 8.18% 91.82% 3.15% 47.59% 41.08% 1131 7.43% 92.57% 3.15% 47.95% 41.47%
1067 8.17% 91.83% 3.15% 47.59% 41.09% 1132 7.42% 92.58% 3.15% 47.96% 41.47%
1068 8.16% 91.84% 3.15% 47.60% 41.09% 1133 7.41% 92.59% 3.15% 47.97% 41.48%
1069 8.16% 91.85% 3.15% 47.60% 41.10% 1134 7.39% 92.61% 3.15% 47.98% 41.48%
1070 8.15% 91.85% 3.15% 47.60% 41.10% 1135 7.38% 92.62% 3.15% 47.98% 41.49%
1071 8.13% 91.87% 3.15% 47.61% 41.11% 1136 7.37% 92.63% 3.15% 47.99% 41.49%
1072 8.11% 91.89% 3.15% 47.62% 41.12% 1137 7.36% 92.64% 3.15% 47.99% 41.50%
1073 8.10% 91.90% 3.15% 47.62% 41.13% 1138 7.35% 92.65% 3.15% 48.00% 41.51%
1074 8.09% 91.91% 3.15% 47.63% 41.14% 1139 7.34% 92.66% 3.15% 48.00% 41.51%
1075 8.08% 91.92% 3.15% 47.64% 41.14% 1140 7.33% 92.67% 3.15% 48.01% 41.52%
1076 8.07% 91.93% 3.15% 47.64% 41.15% 1141 7.31% 92.69% 3.15% 48.01% 41.52%
1077 8.05% 91.95% 3.15% 47.65% 41.15% 1142 7.31% 92.69% 3.15% 48.02% 41.53%
1078 8.04% 91.96% 3.15% 47.65% 41.15% 1143 7.30% 92.70% 3.15% 48.02% 41.53%
1079 8.04% 91.96% 3.15% 47.66% 41.16% 1144 7.29% 92.71% 3.15% 48.02% 41.54%
1080 8.03% 91.97% 3.15% 47.67% 41.16% 1145 7.28% 92.72% 3.15% 48.03% 41.55%
1081 8.02% 91.98% 3.15% 47.67% 41.16% 1146 7.27% 92.74% 3.15% 48.03% 41.56%
1082 8.00% 92.00% 3.15% 47.68% 41.18% 1147 7.25% 92.75% 3.15% 48.04% 41.56%
1083 7.99% 92.01% 3.15% 47.68% 41.18% 1148 7.24% 92.76% 3.15% 48.04% 41.57%
1084 7.98% 92.03% 3.15% 47.69% 41.19% 1149 7.23% 92.77% 3.15% 48.05% 41.58%
1085 7.96% 92.04% 3.15% 47.69% 41.20% 1150 7.22% 92.79% 3.15% 48.06% 41.58%
1086 7.96% 92.04% 3.15% 47.70% 41.20% 1151 7.21% 92.79% 3.15% 48.06% 41.59%
1087 7.95% 92.05% 3.15% 47.70% 41.21% 1152 7.20% 92.80% 3.15% 48.06% 41.59%
1088 7.94% 92.06% 3.15% 47.70% 41.21% 1153 7.19% 92.81% 3.15% 48.07% 41.60%
1089 7.93% 92.07% 3.15% 47.71% 41.22% 1154 7.18% 92.83% 3.15% 48.07% 41.60%
1090 7.91% 92.09% 3.15% 47.72% 41.22% 1155 7.16% 92.84% 3.15% 48.08% 41.61%
1091 7.90% 92.10% 3.15% 47.72% 41.23% 1156 7.14% 92.86% 3.15% 48.09% 41.62%
1092 7.89% 92.11% 3.15% 47.72% 41.24% 1157 7.13% 92.87% 3.15% 48.10% 41.62%
1093 7.88% 92.12% 3.15% 47.73% 41.24% 1158 7.13% 92.87% 3.15% 48.10% 41.63%
1094 7.87% 92.13% 3.15% 47.74% 41.25% 1159 7.12% 92.88% 3.15% 48.10% 41.63%
1095 7.86% 92.14% 3.15% 47.74% 41.25% 1160 7.11% 92.89% 3.15% 48.10% 41.64%
1096 7.84% 92.16% 3.15% 47.74% 41.26% 1161 7.10% 92.90% 3.15% 48.11% 41.65%
1097 7.83% 92.17% 3.15% 47.75% 41.27% 1162 7.09% 92.91% 3.15% 48.11% 41.65%
1098 7.82% 92.18% 3.15% 47.76% 41.28% 1163 7.08% 92.92% 3.15% 48.11% 41.66%
1099 7.81% 92.19% 3.15% 47.76% 41.28% 1164 7.08% 92.93% 3.15% 48.12% 41.66%
1100 7.80% 92.20% 3.15% 47.77% 41.28% 1165 7.07% 92.93% 3.15% 48.12% 41.66%
1101 7.79% 92.21% 3.15% 47.78% 41.28% 1166 7.06% 92.94% 3.15% 48.13% 41.67%
1102 7.78% 92.22% 3.15% 47.78% 41.29% 1167 7.04% 92.96% 3.15% 48.14% 41.67%
1103 7.77% 92.23% 3.15% 47.79% 41.30% 1168 7.03% 92.97% 3.15% 48.14% 41.68%
1104 7.76% 92.24% 3.15% 47.79% 41.30% 1169 7.02% 92.99% 3.15% 48.15% 41.68%
1105 7.75% 92.26% 3.15% 47.80% 41.31% 1170 7.01% 92.99% 3.15% 48.16% 41.69%
1106 7.72% 92.28% 3.15% 47.80% 41.32% 1171 7.00% 93.00% 3.15% 48.16% 41.70%
1107 7.71% 92.29% 3.15% 47.81% 41.33% 1172 6.98% 93.02% 3.15% 48.16% 41.70%
1108 7.70% 92.30% 3.15% 47.82% 41.33% 1173 6.98% 93.03% 3.15% 48.17% 41.71%
1109 7.69% 92.31% 3.15% 47.82% 41.34% 1174 6.97% 93.03% 3.15% 48.17% 41.71%
1110 7.68% 92.32% 3.15% 47.83% 41.34% 1175 6.96% 93.04% 3.15% 48.18% 41.72%
1111 7.67% 92.33% 3.15% 47.83% 41.35% 1176 6.95% 93.05% 3.15% 48.18% 41.72%
1112 7.65% 92.35% 3.15% 47.84% 41.36% 1177 6.95% 93.05% 3.15% 48.18% 41.72%
1113 7.64% 92.36% 3.15% 47.85% 41.36% 1178 6.94% 93.06% 3.15% 48.19% 41.73%
1114 7.63% 92.38% 3.15% 47.86% 41.37% 1179 6.93% 93.07% 3.15% 48.19% 41.73%
1115 7.62% 92.38% 3.15% 47.86% 41.37% 1180 6.92% 93.08% 3.15% 48.20% 41.74%
1116 7.61% 92.39% 3.15% 47.86% 41.38% 1181 6.91% 93.09% 3.15% 48.20% 41.74%
1117 7.61% 92.39% 3.15% 47.87% 41.38% 1182 6.90% 93.10% 3.15% 48.21% 41.74%
1118 7.59% 92.41% 3.15% 47.87% 41.39% 1183 6.90% 93.11% 3.15% 48.21% 41.75%
1119 7.58% 92.42% 3.15% 47.88% 41.39% 1184 6.88% 93.12% 3.15% 48.22% 41.75%
1120 7.56% 92.44% 3.15% 47.89% 41.40% 1185 6.87% 93.13% 3.15% 48.23% 41.76%
1121 7.55% 92.45% 3.15% 47.89% 41.41% 1186 6.85% 93.15% 3.15% 48.23% 41.77%
1122 7.54% 92.46% 3.15% 47.90% 41.42% 1187 6.84% 93.16% 3.15% 48.24% 41.78%
1123 7.53% 92.47% 3.15% 47.91% 41.42% 1188 6.83% 93.17% 3.15% 48.24% 41.78%
268
Days NoLOCA LOCA SBLOCA MBLOCA LBLOCA 1189 6.82% 93.18% 3.15% 48.24% 41.79%
1190 6.81% 93.19% 3.15% 48.25% 41.79%
1191 6.81% 93.19% 3.15% 48.25% 41.80%
1192 6.79% 93.21% 3.15% 48.25% 41.80%
1193 6.79% 93.21% 3.15% 48.26% 41.81%
1194 6.78% 93.22% 3.15% 48.26% 41.81%
1195 6.76% 93.24% 3.15% 48.26% 41.82%
1196 6.76% 93.25% 3.15% 48.27% 41.83%
1197 6.75% 93.26% 3.15% 48.27% 41.84%
1198 6.73% 93.27% 3.15% 48.28% 41.85%
1199 6.71% 93.29% 3.15% 48.28% 41.86%
1200 6.70% 93.30% 3.15% 48.29% 41.86%
269
Appendix C - BWXT Report J. W. Hyres, Examination of the Reactor Pressure Vessel (RV) Head Degradation at Davis-Besse, BWXT Internal Report No. 1140-025-02-024, BWXT Services, Inc., Nuclear and Environmental Operations, Lynchburg, VA, June 2003.