E-mail Regarding Fort Calhoun Response to Bulletin 2003-01, Potential Impact of Debris Blockage on Emergency Sump Recirculation at Pressurized Water Reactors
ML042580046
Person / Time
Site: Fort Calhoun 
Issue date: 09/17/2004
From: Wang A
NRC/NRR/DLPM/LPD4
To:
NRC/NRR/DLPM/LPD4
Wang A, NRR/DLPM, 415-1445
References
TAC MB9577
Download: ML042580046 (5)


Text

September 17, 2004 MEMORANDUM TO: File FROM:

Alan B. Wang, Project Manager, Section 2

/RA/

Project Directorate IV Division of Licensing Project Management Office of Nuclear Reactor Regulation

SUBJECT:

E-MAIL REGARDING FORT CALHOUN RESPONSE TO BULLETIN 2003-01, "POTENTIAL IMPACT OF DEBRIS BLOCKAGE ON EMERGENCY SUMP RECIRCULATION AT PRESSURIZED WATER REACTORS" (TAC NO. MB9577)

The attached e-mail provides a clarification of the candidate operator action to shut down containment spray pumps after a recirculation actuation signal at the Fort Calhoun Station. This information was provided in support of Omaha Public Power Districts response to Bulletin 2003-01.

Docket No. 50-285

Attachment:

E-mail dtd. September 9, 2004

September 17, 2004 MEMORANDUM TO: File FROM:

Alan B. Wang, Project Manager, Section 2

/RA/

Project Directorate IV Division of Licensing Project Management Office of Nuclear Reactor Regulation

SUBJECT:

E-MAIL REGARDING FORT CALHOUN RESPONSE TO BULLETIN 2003-01, "POTENTIAL IMPACT OF DEBRIS BLOCKAGE ON EMERGENCY SUMP RECIRCULATION AT PRESSURIZED WATER REACTORS" (TAC NO. MB9577)

The attached e-mail provides a clarification of the candidate operator action to shut down containment spray pumps after a recirculation actuation signal at the Fort Calhoun Station. This information was provided in support of Omaha Public Power Districts response to Bulletin 2003-01.

Docket No. 50-285

Attachment:

E-mail dtd. September 9, 2004 DISTRIBUTION PUBLIC PDIV-2 Reading RidsNrrDlpmLpdiv2 (RGramm)

RidsNrrPMAWang RidsNrrLAEPeyton LWhitney Accession No.: ML042580046 NRR-106 OFFICE PDIV-2/PM PDIV-2/LA PDIV-2/SC NAME AWang:mp EPeyton RGramm DATE 9/16/04 9/15/04 9/17/04 G:/DLPM/PDVI-2/FortCalhoun/EmailBul200301.wpd OFFICIAL RECORDS COPY

From: "BYRNE, THOMAS R" <trbyrne@oppd.com>

To:

"Alan Wang" <ABW@nrc.gov>

Date: 9/9/04 3:13PM

Subject:

Response to RAIs on NRC Bulletin 2--3-01 Alan:

The purpose of this email is to provide minor clarification on information contained on Page 7 of the attachment to the submittal dated June 11, 2004, Response to Requests for Additional Information on the Fort Calhoun Station Unit No. 1 Response to NRC Bulletin 2003-01, "Potential Impact of Debris Blockage on Emergency Sump Recirculation at Pressurized-Water Reactors" (LIC-04-0072).

The information under the heading "Securing two [High Pressure Safety Injection Pumps] HPSI Pumps" applies before or after the Recirculation Actuation Signal (RAS) is received, i.e., it was determined that securing two of three HPSI pumps (reducing to one operating HPSI pump) either before or after RAS was found to be inappropriate for Fort Calhoun Station (FCS) for the reasons provided in the submittal. Please contact me if you require any additional information. Thanks!

Tom Thomas R. Byrne Engineer - Nuclear Licensing Omaha Public Power District Fort Calhoun Station Phone: (402) 533-7368 Fax: (402) 533-7291 Email: trbyrne@oppd.com

This e-mail contains Omaha Public Power Districts confidential and proprietary information and is for use only by the intended recipient. Unless explicitly stated otherwise, this e-mail is not a contract offer, amendment, nor acceptance. If you are not the intended recipient you are notified that disclosing, copying, distributing or taking any action in reliance on the contents of this information is strictly prohibited.

CC:

"LAKE, FRED D" <fdlake@oppd.com>, "FRIEDMAN, MICHAEL J"

<mjfriedman@oppd.com>, "MATTHEWS, THOMAS C" <tcmatthews@oppd.com>, "HERMAN, JOHN B" <jherman@oppd.com>

From:

"BYRNE, THOMAS R" <trbyrne@oppd.com>

To:

"Alan Wang" <ABW@nrc.gov>

Date:

9/17/04 12:55PM

Subject:

RE: Response to RAIs on NRC Bulletin 2003-01 Alan:

What you propose is acceptable. Thanks for the information.

Tom Thomas R. Byrne Engineer - Nuclear Licensing Omaha Public Power District Fort Calhoun Station Phone: (402) 533-7368 Fax: (402) 533-7291 Email: trbyrne@oppd.com


Original Message-----

From: Alan Wang [1]

Sent: Friday, September 17, 2004 11:50 AM To: BYRNE, THOMAS R

Subject:

Re: Response to RAIs on NRC Bulletin 2--3-01 Tom, this is to inform you that I plan to place the information provided below into the public domain by a memorandum to file. Please let me know if this acceptable. Alan

>>> "BYRNE, THOMAS R" <trbyrne@oppd.com> 09/09/04 03:10PM >>>

Alan:

The purpose of this email is to provide minor clarification on information contained on Page 7 of the attachment to the submittal dated June 11, 2004, Response to Requests for Additional Information on the Fort Calhoun Station Unit No. 1 Response to NRC Bulletin 2003-01, "Potential Impact of Debris Blockage on Emergency Sump Recirculation at Pressurized-Water Reactors" (LIC-04-0072).

The information under the heading "Securing two [High Pressure Safety Injection Pumps] HPSI Pumps" applies before or after the Recirculation Actuation Signal (RAS) is received, i.e., it was determined that securing two of three HPSI pumps (reducing to one operating HPSI pump) either before or after RAS was found to be inappropriate for Fort Calhoun Station (FCS) for the reasons provided in the submittal. Please contact me if you require any additional information. Thanks! Tom Thomas R. Byrne Engineer - Nuclear Licensing Omaha Public Power District Fort Calhoun Station Phone: (402) 533-7368 Fax: (402) 533-7291

Email: trbyrne@oppd.com

This e-mail contains Omaha Public Power Districts confidential and proprietary information and is for use only by the intended recipient. Unless explicitly stated otherwise, this e-mail is not a contract offer, amendment, nor acceptance. If you are not the intended recipient you are notified that disclosing, copying, distributing or taking any action in reliance on the contents of this information is strictly prohibited.

This e-mail contains Omaha Public Power Districts confidential and proprietary information and is for use only by the intended recipient. Unless explicitly stated otherwise, this e-mail is not a contract offer, amendment, nor acceptance. If you are not the intended recipient you are notified that disclosing, copying, distributing or taking any action in reliance on the contents of this information is strictly prohibited.