August 30, 2004 Mr. Christopher M. Crane President and Chief Nuclear Officer Exelon Nuclear Exelon Generation Company, LLC Quad Cities Nuclear Power Station 4300 Winfield Road Warrenville, IL 60555
SUBJECT:
MID-CYCLE PERFORMANCE REVIEW AND INSPECTION PLAN -
QUAD CITIES NUCLEAR POWER STATION (REPORT 50-254/05-01; 50-265/05-01)
Dear Mr. Crane:
On August 11, 2004, the NRC staff completed its mid-cycle plant performance assessment of the Quad Cities Nuclear Power Station. The mid-cycle review involved the participation of all technical divisions in evaluating performance for the first half of the calendar year 2004 assessment cycle. The process included a review of performance indicators (PIs) for the most recent quarter and inspection results over the previous 12 months. The purpose of this letter is to inform you of our assessment of your safety performance during this period and our plans for future inspections at your facility so that you will have an opportunity to prepare for these inspections and to inform us of any planned inspections that may conflict with your plant activities.
Plant performance for the most recent quarter was within the Licensee Response Column of the NRCs Action Matrix, based on all inspection findings being classified as having very low safety significance (Green) and all PIs indicating performance at a level requiring no additional NRC oversight (Green). Therefore, we plan to conduct only reactor oversight process baseline inspections at your facility through March 31, 2006.
As discussed In our Annual Assessment Letter dated March 4, 2004, extended power uprate (EPU) implementation and the high radiological source term for both units continued to challenge your organization. In a letter to the NRC dated April 2, 2004, you provided new information and commitments associated with the discovery of cracking in a previously repaired area of the Unit 2 steam dryer. The commitments included limiting the operation of both units to the maximum original licensed power level, repairing the Unit 1 electromatic relief valves prior to increasing power to EPU levels (the Unit 2 valves have been repaired), and providing additional commitments for obtaining NRC acceptance prior to resuming continuous operation of both units at EPU levels. We acknowledged this letter on April 20, 2004. In a letter dated May 12, 2004, you formally documented your commitments and plans related to extended power uprate operation. Representatives from Exelon and the NRC plan to meet in the third quarter of 2004 to discuss the results of the review to identify potential EPU-related equipment vulnerabilities and the plans to monitor the performance of the steam dryers and other potentially affected components. During the February 2004 Unit 2 refueling outage, you
C. Crane chemically decontaminated portions of the reactor recirculation piping, installed permanent shielding in the drywell, and replaced the low pressure turbine buckets as part of your source term reduction project. These efforts resulted in a 75 percent reduction in drywell dose rates and a 45 percent reduction in elemental cobalt.
The enclosed inspection plan details the inspections scheduled through March 31, 2006. The inspection plan is provided to minimize the resource impact on your staff and to allow for scheduling conflicts and personnel availability to be resolved in advance of inspector arrival onsite. The plan contains an inspection using Temporary Instruction (TI) 2515/159, "Review of Generic Letter 89-13, Service Water System Problems Affecting Safety-Related Equipment."
This TI is in response to the Davis-Besse Reactor Vessel Head Degradation Lessons-Learned Task Force and is being performed at a sample of nuclear power plants across the country.
The plan also contains inspections using Independent Spent Fuel Storage Installation procedures. Routine resident inspections are not listed due to their ongoing and continuous nature. The inspections in the last 12 months of the inspection plan are tentative and may be revised at the end-of-cycle review meeting.
In accordance with 10 CFR 2.390 of the NRC's "Rules of Practice," a copy of this letter and its enclosure will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of NRC's document system (ADAMS). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room).
Sincerely,
/RA/
Mark A. Ring, Chief Branch 1 Division of Reactor Projects Docket Nos. 50-254; 50-265 License Nos. DPR-29; DPR-30
Enclosure:
Quad Cities Inspection/Activity Plan See Attached Distribution
C. Crane chemically decontaminated portions of the reactor recirculation piping, installed permanent shielding in the drywell, and replaced the low pressure turbine buckets as part of your source term reduction project. These efforts resulted in a 75 percent reduction in drywell dose rates and a 45 percent reduction in elemental cobalt.
The enclosed inspection plan details the inspections scheduled through March 31, 2006. The inspection plan is provided to minimize the resource impact on your staff and to allow for scheduling conflicts and personnel availability to be resolved in advance of inspector arrival onsite. The plan contains an inspection using Temporary Instruction (TI) 2515/159, "Review of Generic Letter 89-13, Service Water System Problems Affecting Safety-Related Equipment."
This TI is in response to the Davis-Besse Reactor Vessel Head Degradation Lessons-Learned Task Force and is being performed at a sample of nuclear power plants across the country.
The plan also contains inspections using Independent Spent Fuel Storage Installation procedures. Routine resident inspections are not listed due to their ongoing and continuous nature. The inspections in the last 12 months of the inspection plan are tentative and may be revised at the end-of-cycle review meeting.
In accordance with 10 CFR 2.390 of the NRC's "Rules of Practice," a copy of this letter and its enclosure will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of NRC's document system (ADAMS). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room).
Sincerely,
/RA/
Mark A. Ring, Chief Branch 1 Division of Reactor Projects Docket Nos. 50-254; 50-265 License Nos. DPR-29; DPR-30
Enclosure:
Quad Cities Inspection/Activity Plan See Attached Distribution DOCUMENT NAME: G:\\Branch TSS\\midcycle 2004\\Midcycle Ltrs\\Qua.wpd To receive a copy of this document, indicate in the box:"C" = Copy without enclosure "E"= Copy with enclosure"N"= No copy OFFICE RIII RIII NAME PPelke:co Ring DATE 08/27/04 08/30/04 OFFICIAL RECORD COPY
C. Crane cc w/encl:
Site Vice President - Quad Cities Nuclear Power Station Plant Manager - Quad Cities Nuclear Power Station Regulatory Assurance Manager - Quad Cities Nuclear Power Station Chief Operating Officer Senior Vice President - Nuclear Services Senior Vice President - Mid-West Regional Operating Group Vice President - Mid-West Operations Support Vice President - Licensing and Regulatory Affairs Director Licensing - Mid-West Regional Operating Group Manager Licensing - Dresden and Quad Cities Senior Counsel, Nuclear, Mid-West Regional Operating Group Document Control Desk - Licensing Vice President - Law and Regulatory Affairs Mid American Energy Company Assistant Attorney General Illinois Department of Nuclear Safety State Liaison Officer, State of Illinois State Liaison Officer, State of Iowa Chairman, Illinois Commerce Commission D. Tubbs, Manager of Nuclear MidAmerican Energy Company
C. Crane ADAMS Distribution:
DFT DWW Project Director, NRR Project Mgr., NRR RidsNrrDipmlipb JLC1 GEG HBC RML2 SRI Quad Cities DRPIII DRSIII PLB1 JRK1
Quad Cities Inspection / Activity Plan 09/01/2004 - 03/31/2006 Inspection Type Inspection Activity Planned Dates Start End No. of Staff on Site Title Unit Number Page 1 of 2 08/27/2004 11:22:11 Report 22 3
TI ON SW
- TI 2515/159: GL 89-13 SERVICE WATER Safety Issues 09/13/2004 09/17/2004 Review of Generic Letter 89-13: Service Water System Problems Affecting Safety-Related Equipment IP 2515/159 1, 2 1
- ONSITE FAB AND CONSTRUCTION OF ISFSI Other Routine 08/02/2004 12/31/2004 On-Site Fabrication Of Components And Construction On An ISFSI IP 60853 1, 2 4
- PROBLEM ID AND RESOLUTION Baseline Inspections 10/18/2004 11/05/2004 Identification and Resolution of Problems IP 71152B 1, 2 1
7112201
- EFFLUENTS, PI VERIFICATION Baseline Inspections 11/15/2004 11/19/2004 Access Control to Radiologically Significant Areas IP 7112101 1, 2 Baseline Inspections 11/15/2004 11/19/2004 Radioactive Gaseous and Liquid Effluent Treatment and Monitoring Systems IP 7112201 1, 2 Baseline Inspections 11/15/2004 11/19/2004 Performance Indicator Verification IP 71151 1, 2 1
71114
- BASELINE EP INSPECTION Baseline Inspections 01/31/2005 02/04/2005 Alert and Notification System Testing IP 7111402 1, 2 Baseline Inspections 01/31/2005 02/04/2005 Emergency Response Organization Augmentation Testing IP 7111403 1, 2 Baseline Inspections 01/31/2005 02/04/2005 Correction of Emergency Preparedness Weaknesses and Deficiencies IP 7111405 1, 2 Baseline Inspections 01/31/2005 02/04/2005 Performance Indicator Verification IP 71151 1, 2 1
- UNIT 1 ISI INSPECTION Baseline Inspections 03/07/2005 03/11/2005 Inservice Inspection Activities - BWR IP 7111108G 1
1 OUTAGE
- ACCESS CONTROL AND ALARA Baseline Inspections 03/07/2005 03/11/2005 Access Control to Radiologically Significant Areas IP 7112101 1, 2 Baseline Inspections 03/07/2005 03/11/2005 ALARA Planning and Controls IP 7112102 1, 2 3
FY 2005
- QUAD CITIES INIT PREP 04/2005 Not Applicable 04/04/2005 04/08/2005 OL - INITIAL EXAM - QUAD CITIES - APR/MAY 2005 W90129 1
3 FY 2005
- QUAD CITIES INIT EXAM 05/2005 Not Applicable 05/02/2005 05/06/2005 OL - INITIAL EXAM - QUAD CITIES - APR/MAY 2005 W90129 1
1 71122.03
- REMP, ACCESS CONTROL Baseline Inspections 06/27/2005 07/01/2005 Access Control to Radiologically Significant Areas IP 7112101 1, 2 Baseline Inspections 06/27/2005 07/01/2005 Radiological Environmental Monitoring Program IP 7112203 1, 2 1
MAINT
- BIENNIAL MAINTENANCE RULE INSPECTION Baseline Inspections 08/15/2005 08/19/2005 Maintenance Effectiveness IP 7111112B 1, 2 1
- ISFSI INSPECTION ACTIVITIES Other Routine 08/01/2005 09/30/2005 Preoperational Testing Of An ISFSI IP 60854 1, 2 Other Routine 08/01/2005 09/30/2005 Review of 10 CFR 72.212(b) Evaluations IP 60856 1, 2 Other Routine 08/01/2005 10/31/2005 Review of 10 CFR 72.48 Evaluations IP 60857 1, 2 Other Routine 09/01/2005 10/31/2005 Operation Of An ISFSI IP 60855 1, 2 This report does not include INPO and OUTAGE activities.
This report shows only on-site and announced inspection procedures.
Quad Cities Inspection / Activity Plan 09/01/2004 - 03/31/2006 Inspection Type Inspection Activity Planned Dates Start End No. of Staff on Site Title Unit Number Page 2 of 2 08/27/2004 11:22:11 Report 22 3
MOD/5059
- MODIFICATIONS/50.59 INSPECTION Baseline Inspections 10/03/2005 10/07/2005 Evaluation of Changes, Tests, or Experiments IP 7111102 1, 2 Baseline Inspections 10/03/2005 10/07/2005 Permanent Plant Modifications IP 7111117B 1, 2 2
- LIC OPERATOR REQUAL PROGRAM EVALUATION Baseline Inspections 10/24/2005 10/28/2005 Licensed Operator Requalification Program IP 7111111B 1, 2 1
- INSTRUMENTATION Baseline Inspections 11/14/2005 11/18/2005 Radiation Monitoring Instrumentation and Protective Equipment IP 7112103 1, 2 Baseline Inspections 11/14/2005 11/18/2005 Performance Indicator Verification IP 71151 1, 2 1
- ALARA, ACCESS CONTROL Baseline Inspections 03/13/2006 03/27/2006 Access Control to Radiologically Significant Areas IP 7112101 1, 2 Baseline Inspections 03/13/2006 03/27/2006 ALARA Planning and Controls IP 7112102 1, 2 1
- UNIT 2 ISI Baseline Inspections 03/20/2006 03/24/2006 Inservice Inspection Activities - BWR IP 7111108G 2
This report does not include INPO and OUTAGE activities.
This report shows only on-site and announced inspection procedures.