A TXU "9Power TXU Power Mike Blevins Comanche Peak Steam Senior Vice President &

Electric Station Chief Nuclear Officer P.O. Box 1002 (EO1)

Glen RoseT 7604 Ref: 10 CFR 50.55a Tel: 254 897 5209 Fax: 254 897 6652 mike.blevins~txu.com CPSES-200401982 Log # TXX-04157 RP-39 August 27, 2004 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555

SUBJECT:

COMANCHE PEAK STEAM ELECTRIC STATION (CPSES)

UNIT I TENTH REFUELING OUTAGE (IRFIO)

STEAM GENERATOR TWELVE MONTH REPORT REF:

1)

TXU Energy letter, logged TXX-04085, from Mike Blevins to the NRC; dated April 27, 2004.

2)

TXU Power letter, logged TXX-04141, from Mike Blevins to the NRC; dated July 29, 2004.

Gentlemen:

As Attachment I to this letter, TXU Generation Company LP (TXU Power) submits the Technical Specification 5.6.10.b twelve month report of the results of the steam generator tube inservice inspection completed during CPSES Unit 1 tenth refueling outage. Also included as an enclosure to this submittal is the 120-day condition monitoring report prepared pursuant to the guidance of NEI 97-06.

The IRFI0 fifteen-day tube plugging report and condition C-3 report were previously submitted via Reference 1. The IRFIO 90-day report prepared pursuant to the guidance of Generic Letter (GL) 95-05 "Voltage-Based Repair Criteria for Westinghouse Steam Generator Tubes Affected by Outside Diameter Stress Corrosion Cracking" was previously submitted via Reference 2.

A member of the STARS (Strategic Teaming and Resource Sharing) Alliance Callaway

  • Comanche Peaks Diablo Canyon
  • Palo Verde
  • Wolf Creek

TXX-04157 Page 2 of 3 Enclosure I to this letter, SG-SGDA-04-21 Revision 1, is the CPSES IRFI0 Condition Monitoring Report and contains information proprietary to Westinghouse Electric Company LLC ("Westinghouse"). This report is supported by an affidavit signed by Westinghouse (Enclosure 3), the owner of the information. This affidavit sets forth the basis on which the information may be withheld from public disclosure by the NRC, and addresses with specificity the consideration listed in paragraph (b)(4) of Section 2.790 of the 10 CFR 50. Accordingly, it is requested that the information which is proprietary to Westinghouse be withheld from public disclosure in accordance with 10 CFR Section 2.790 of the Commission's regulations. of this letter contains the non-proprietary version of Enclosure 1. contains the Westinghouse authorization letter CAW-04-1882, accompanying affidavit, Proprietary Information Notice and Copyright Notice.

Correspondence with respect to the copyright or proprietary aspects of the enclosed Westinghouse documents or the supporting Westinghouse affidavit should reference CAW-04-1882 and should be addressed to J.A. Gresham, Manager of Regulatory Compliance and Plant Licensing, Westinghouse Electric Company LLC, P.O. Box 355, Pittsburgh, Pennsylvania 15230-0355.

Should you require any other additional information please contact Mr. Bob Kidwell at (254) 897-5310.

This communication contains the no new licensing basis commitments concerning CPSES Unit 1.

Sincerely, TXU Generation Company LP By:

TXU Generation Management Company LLC, Its General Partner Mike Blevins By:

__x Mitch L. Lucas Vice President, Nuclear Engineering

TXX-041 57 Page 3 of 3 RJK Attachment Enclosures c -

B. S. Mallett, Region IV W. D. Johnson, Region IV M. C. Thadani, NRR Resident Inspectors, CPSES w/o End w/o End w/o End w/o End

Attachment I to TXX-04157 Page 1 of 19 TXU POWER COMANCHE PEAK STEAM ELECTRIC STATION UNIT 1, TENTH REFUELING OUTAGE (IRF10) 12 MONTH REPORT OF STEAM GENERATOR TUBE INSPECTION RESULTS TECHNICAL SPECIFICATION 5.6.10.b to TXX-04157 Page2of 19 CPSES 1RF10 Initial Inspection Plan The CPSES IRF10 inspection plan exceeded both the Technical Specification minimum requirements as well as the recommendations of EPRI TR-1003138, PWR Steam Generator Examination Guidelines: Revision 6 requirements. The IRF10 initial inspection plan for all four Steam Generators (SGs) included:

1) 100% full length bobbin inspection in Rows 3 and greater and 100% bobbin inspection in the hot and cold leg straight sections of Rows 1 and 2
2) 100% hot leg top of tubesheet (TTS) +Pt inspection from (+/- 3") for hard rolled expanded tubes and from +3 to hot leg tube end for WEXTEX expanded tubes
3) 20% +Pt inspection of hard rolled expanded tubes in the cold leg TTS (+/- 3")
4) 100% Row 1 through 10 U-bend mid-range +Pt inspection
5) 20% Row 11 through 22 U-bend mid-range +Pt inspection
6) 25% +Pt inspection of tubes expanded at cold leg baffles B (C2) and D (C3)
7)

+Pt inspection of dents, regardless of voltage, at AVB locations

8)

Rotating probe inspection of mixed residuals > 1.5 volts (by bobbin) and hot leg dented intersections > 5 volts (by bobbin) according to the requirements of GL 95-05

9)

Rotating probe inspection of preheater baffle plate indications and freespan bobbin coil indications for flaw confirmation and characterization

10) 100% +Pt inspection of all dented TSP intersections at the H3 TSP > 2 volts
11) 20% +Pt inspection of freespan dings > 2 volts and < 5 volts between TSH and H3
12) 100% +Pt inspection of freespan dings > 5 volts
13) 20% +Pt freespan paired ding inspection between the top 2 TSPs (hot leg and cold leg)
14)

Inspection of tubes deplugged during IRF1O consistent with the above plan except TTS +Pt inspection

15)

+Pt inspection of tubes selected for installation of Alloy 800 sleeves, in the region of lower roll joint (TIS -7.0" to -10.0")

16) 100% +Pt inspection of sleeves (SGs 2, 3, 4) installed in lRF09 (weld to expansion in tubesheet)
17)

Baseline +Pt inspection of all A800 sleeves installed during 1RFI0

18) 100% tube plug visual inspection
19)

Secondary side video inspection including a limited scope TTS in-bundle inspection and FOSAR at TTS and cold leg baffle plate B The inspection plan was developed to specifically address the areas of active degradation, those areas expected to be affected based on recent industry experience as well as experience from the CPSES lRF09 outage in October 2002.

Attachment I to TXX-04157 Page3of 19 A C-3 condition was reported for all SGs due to the detection of >45 circumferentially oriented ODSCC indications of degradation at the top oftubesheet location. Since the IRF10 base scope inspection program included a 100% sample of the hot leg top of tubesheet expansion transitions and a 20% sample of the cold leg top of tubesheet expansion transitions, the requirements of Section 3.4.1 of the EPRI SG Examination Guideline Revision 6 were satisfied and no further expansion was required.

The cold leg top of tubesheet expansion program was expanded an additional 20% in SGI based on the observation of a volumetric signal in tube R4 C91. No additional degradation was reported. Upon further review, this indication was judged to be a conservative overcall.

Based on the observation of oblique PWSCC in Row 10 in SGs 1 and 2, the U-bend inspection program was expanded to include 100% of Rows 11 through 21 in all SGs. Indications were observed in Row 13 tubes in SGs 3 (1 tube) and 4 (3 tubes), however, no further expansion of the inspection scope was required as this row was bounded by the critical area redefinition.

The U-bend inspection scope for dents at AVBs was expanded to include all dings within +

1.00" of the AVB. This expansion was necessitated based on observation of a ding ODSCC detected by +Pt at approximately 0.6" from the AVB.

to TXX-04157 Page4of 19 Unit 1 Tube Plugging by Refuel Outage Cycle EFPY l SG 1

-'SG 2 SG 3 SG 4 Totali Pre Service 0

14 4

5 11 34 lRF0I 0.9155

-2

-1 0

0

-3 1RF02 1.6859 0

0 0

0 0

IRF03 2.4164 0

0 0

0 0

IRF04 3.5876 0

1 1

0 2

IRFO5 4.9304 0

11 2

6 19 IRF06 6.2436 0

67 8

27 102 1RF07 7.6410 8

20 35 57 120 IRF08 9.0271 11 58 85 55 209 1RF09 10.4194 48

-7 ()

-11 (2)

-17(3) 13 1,pi R

F I 6nQ I

-1.6909

-1l 5 t

_l; If% _1 {I'M

-24 In r Total Effective Tubes Total % per SG

-s.,

as, v.

a.,

". 'Is

-.1' 64 92 110 115 381 1.40%

2.01%

2.40%

2.51%

2.08%

NOTES:

(1) 18 tubes plugged, 33 tubes deplugged and 213 tubes sleeved (LTS)

(2) 22 tubes plugged, 42 tubes deplugged and 250 tubes sleeved (LTS)

(3) 12 tubes plugged, 39 tubes deplugged and 273 tubes sleeved (LTS)

(4) 14 tubes plugged, 32 tubes deplugged and 78 tubes sleeved (LLS)

(5) 33 tubes plugged, 100 tubes deplugged and 180 tubes sleeved (LLS) (less 14 LTS sleeved tubes plugged)

(6) 47 tubes plugged, 66 tubes deplugged and 145 tubes sleeved (LLS) (less 27 LTS sleeved tubes plugged)

(7) 43 tubes plugged, 72 tubes deplugged and 144 tubes sleeved (LLS) (less 19 LTS sleeved tubes plugged)

(8) Hydraulic Equivalence of Leak Tight Sleeves (LTS) = 28.3:1 and Leak Limiting Sleeves (LLS) = 27.5:1 to TXX-04157 Page5of 19 Inspection Results The inspection results are included in the following tables which list previously plugged tubes returned to service via plug removal/sleeve installation, those tubes with percent through wall indications, those tubes with indications that required repair via installation of mechanical plugs and those tubes that were repaired via sleeve installation. The indications listed in the following tables are defined as:

DNG: Ding DNT: Dent MAI: multiple axial indication MCI: multiple circumferential indication PCT: percent through wall indication PSC: Possible Sleeve Collapse PVN: Permeability variation RRT: Restricted tube SAL:

single axial indication SCI:

single circumferential indication SVI:

single volumetric indication to TXX-04157 Page 6 of 19 SG 1 Tubes that were Returned to Service by Plug Removal and Sleeve Installation ROW COL 2

8 6

8 5

17 10 20 17 22 4

23 4

26 19 26 ROW COL 7

37 28 38 15 43 23 44 24 47 26 48 3

57 9

60 ROW COL 20 62 6

65 13 68 49 68 19 71 7

72 28 72 27 74 ROW COL 38 79 8

82 20 84 20 91 31 91 28 95 21 96 22 103 SG 1 Tubes with Percent Through Wall Indications ROW COL IND PER LOCN INCHI 34 13 PCT 22 AV2

-0.06 45 29 PCT 23 AV1 0

48 42 PCT 6

C3 0.42 49 52 PCT 4

C7

-0.23 20 58 PCT 6

C3 0.03 20 58 PCT 10 C3

-0.29 21 60 PCT 4

C5 0.26 47 67 PCT 9

C3

-0.23 47 69 PCT 7

C3

-0.26 45 71 PCT 13 C3

-0.09 36 72 PCT 6

C2

-0.32 47 73 PCT 3

C3

-0.32 48 73 PCT 24 C2 0.09 48 73 PCT 25 C3

-0.4 48 73 POT 5

C5

-0.15 48 73 PCT 3

C7

-0.49 ROW COL IND PER LOCNlINCHI 48 74 PCT 6

C7

-0.43 47 75 PCT 6

C2

-0.12 47 75 PCT 8

C3

-0.14 48 75 PCT 11 C2 0.06 48 75 PCT 34 C3

-0.11 48 75 PCT 8

C5

-0.15 48 75 PCT 2

C7

-0.46 48 76 PCT 11 C2 0.06 48 76 PCT 27 C3

-0.09 48 77 PCT 12 C3 0

48 78 PCT 5

C5 0.31 48 79 PCT 3

C3

-0.43 48 79 PCT 3

C5

-0.41 48 79 PCT 5

C5 0.29 45 82 PCT 3

C7

-0.43

Attachment I to TXX-041 57 Page 7 of 19 SG 1 Tubes that were Removed from service by Mechanical Plugging ROW COL IND LOCN INCH 1 14 4

SCI HTS

-0.15 22 12 PVN AV3 5.82 44 25 SCI HTS 0

38 28 SCI HTS 0

48 30 SAI AVI 0.76 25 45 SVI C8 0.24 46 47 DNG CTS 3.16 ROW COL IND LOCN INCH1 27 51 SAI CIO 37.19 7

63 SAI CIO 13.51 25 68 SCI HTS

-0.28 44 90 SAI HTS

-1.01 4

91 SVI CTS 0.1 36 100 SVI C2 1.48 10 105 SCI HI1 23.46 SG I Tubes that were Repaired by Sleeving at the Hot Leg Tubesheet ROW I COL 2

8 6

8 6

11 5

17 10 20 17 21 17 22 4

23 4

26 16 26 19 26 14 27 16 29 7

37 15 37 25 38 28 38 17 42 15 43 23 44 ROW COL 24 47 28 47 26 48 13 49 8

51 17 55 3

57 9

59 5

1 60 6

60 9

60 12 60 20 62 8

64 13 64 6

65 28 65 29 66 13 68 15 68 ROW COL 49 68 33 69 1

70 26 70 1

71 3

71 11 71 14 71 15 71 19 71 7

72 8

72 12 72 13 72 28 72 5

73 13 73 5

74 6

74 10 74 ROW COL 27 74 2

75 3

75 13 75 14 75 27 75 38 79 8

82 18 83 20 84 20 91 31 91 22 92 26 1 95 28 95 21 96 21 101 22 103

Attachment I to TXX-04157 Page8of 19 SG 2 Tubes that were Returned to Service by Plug Removal and Sleeve Installation ROW COL 23 14 1

20 3

22 1

23 1

30 19 42 21 42 18 43 22 44 23 44 12 46 26 46 2

48 2

49 2

51 37 51 8

52 37 52 7

53 24 53 27 53 32 55 38 55 40 55 1

56 ROW COL 5

56 3

59 1

61 39 61 3

64 37 65 1

66 1

67 2

67 5

67 27 67 36 67 3

68 1

69 2

69 3

69 5

69 1

70 3

70 6

70 2

72 18 72 22 72 173 25 73 ROW COL l 34 73 1

74 3

74 15 74 3

77 1

78 1

79 3

79 1

80 6

80 6

81 2

82 3

82 25 82 1

83 2

83 27 83 1

84 3

84 1

85 3

85 4

85 21 85 1

187 3

87 ROW COL 1

88 3

88 1

89 2

89 3

89 22 89 2

90 1

91 3

91 1

92 3

92 17 92 3

93 15 93 1

94 4

94 1

95 3

95 3

96 1

97 1

98 1

101 1

102 5

102 3

103

Attachment I to TXX-04157 Page9of 19 SG 2 Tubes with Percent Through Wall Indications ROW COL IND PER LOCN INCH1 48 33 PCT 8

C2 0.26 48 33 PCT 5

C3 0.46 48 33 PCT 6

C7

-0.23 48 37 PCT 5

C7 0.14 48 38 PCT 17 C2 0.32 48 38 PCT 11 C3

-0.09 48 38 PCT 15 C7

-0.31 49 38 PCT 5

C7

-0.4 47 39 PCT 7

C7

-0.09 48 39 PCT 11 C3 0.37 48 39 PCT 3

C5 0.37 48 39 PCT 9

C7 0.11 48 39 PCT 5

C8 0.32 48 39 PCT 5

C9 0.35 47 40 PCT 12 C2 0.2 47 40 PCT 2

C7

-0.2 48 40 POT 3

02 0.29 48 40 PCT 44 C3 0.29 48 40 PCT 14 C5

-0.2 48 40 PCT 12 C7 0

48 40 PCT 4

C8 0.2 48 42 PCT 7

C3

-0.23 45 43 PCT 5

C7

-0.49 44 45 PCT 3

C3

-0.34 46 45 PCT 10 C3

-0.03 46 45 PCT 13 C7

-0.35 47 45 PCT 19 C3 0.26 49 45 PCT 11 C7

-0.17 49 46 PCT 19 C7

-0.2 44 47 PCT 10 C2 0.2 49 47 PCT 2

C7

-0.23 ROW COL IND PER LOCN INCH1 45 48 PCT 13 C2 0.12 47 48 PCT 15 C2 0.09 47 48 PCT 19 C3 0.43 47 49 PCT 5

C2 0.15 47 49 PCT 27 C3

-0.06 47 49 PCT 5

C5

-0.14 46 50 PCT 25 C3

-0.35 44 53 PCT 6

C2

-0.17 36 56 PCT 12 C2

-0.03 36 56 PCT 9

C3 0.17 35 59 PCT 6

C2 0.32 44 60 PCT 14 C2 0.34 44 60 PCT 7

C3 0.14 45 60 PCT 9

C3 0.23 42 62 PCT 9

C2 0.17 46 67 PCT 17 C3 0.23 47 67 PCT 8

C2 0.26 47 67 PCT 38 C3 0.23 47 68 PCT 6

C2 0.2 47 68 PCT 6

C3 0.4 46 70 PCT 4

C3 0.26 47 71 PCT 6

C3 0.32 45 73 PCT 4

C3 0.32 47 73 PCT 17 C3

-0.14 48 73 PCT 9

C2 0.11 48 73 PCT 5

C3 0.2 48 75 PCT 4

C7

-0.4 48 76 PCT 4

C5

-0.4 48 79 PCT 10 C3 0.11 48 79 PCT 4

C5 0.06 49 80 PCT 4

C5 0.26 to TXX-04157 Page lOof 19 SG 2 Tubes that were Removed from Service by Mechanical Plugging ROW COL IND LOCN INCH1 27 8

SAI AV3 0.4 10 10 SCI H11 14.94 3

29 RRT 25 29 SAI HTE 2.39 19 30 SAI AV4 17.11 37 35 SAI C9 31.05 4

37 SCI H11 18.73 19 38 DNG C4 9.31 48 40 PCT C3 0.29 37 43 PSC 14 48 SAI H3 4.04 7

59 SVI C9 0.34 4

64 SCI HTS

-0.05 15 65 PSC 20 68 PSC 31 68 RRT 13 69 RRT ROW COL IND LOCN INCHI 12 70 RRT 28 70 RRT 18 71 RRT 36 73 MCI HTS

-0.03 4

75 SAI C9 34.39 3

78 RRT 12 78 SAI H3 25.25 42 78 SAI AV2 26.36 5

79 PSC 26 80 RRT 4

83 RRT 16 99 PSC 4

103 PSC 4

104 DNG H11 10.51 8

111 SCI HTS

-0.31 18 111 SVI HTS

-0.14

Attachment I to TXX-04157 Page II of 19 SG 2 Tubes that were Repaired by Sleeving at the Hot Lei ROW COL 14 10 23 14 1

19 27 19 1

20 2

21 3

22 1

23 20 26 1

27 9

27 11 27 1

28 1

30 30 33 10 36 11 39 21 40 15 42 19 42 21 42 2

43 12 43 18 43 12 44 22 44 23 44 26 44 12 46 26 46 2

48 2

49 12 49 2

51 37 51 8

52 37 52 7

53 24 53 27 53 32 55 38 55 40 55 1

56 5

56 ROW COL 3

59 5

59 6

60 8

60 10 60 11 60 20 60 1

61 5

61 9

61 10 61 11 61 15 61 39 61 5

62 8

62 2

63 5

63 14 63 3

64 37 65 1

66 1

67 2

67 5

67 11 67 13 67 27 67 29 67 31 67 36 67 3

68 1

69 2

69 3

69 5

69 24 69 1

70 3

70 6

70 10 70 13 70 17 71 32 71 2

72 ROW COL 18 72 22 72 37 72 38 72 39 72 41 72 42 72 1

73 2

73 1 1 73 20 73 25 73 34 73 37 73 1

74 3

74 8

74 15 74 23 75 28 76 3

77 1

78 19 78 34 78 36 78 1

79 3

79 18 79 22 79 33 79 1

80 6

80 23 80 27 80 35 80 6

81 22 81 38 81 2

82 3

82 12 82 25 82 1

83 2

83 15 83 Tubesheet ROW COL 27 83 37 83 1

84 3

84 1

85 3

85 4

85 21 85 34 85 1

87 3

87 1

88 3

88 13 88 1

89 2

89 3

89 22 89 2

90 13 90 1

91 3

91 1

92 3

92 17 92 3

93 15 93 1

94 4

94 12 94 1

95 3

95 3

96 1

97 1

98 3

98 1

101 2

101 1

102 2

102 5

102 3

103 14 103 15 104 1

110 to TXX-04157 Page 12 of 19 SG 3 Tubes that were Returned to Service by Plug Removal and Sleeve Installation ROW COL 7

9 1

18 20 20 2

21 9

22 2

23 3

25 3

29 2

30 1

34 2

34 3

34 22 34 2

35 27 36 2

37 3

37 ROW COL 24 39 2

40 4

40 4

_ 41 2

44 23 45 28 47 37 47 24 48 24 49 24 50 6

51 24 51 11 52 25 52 29 52 32 54 ROW COL 29 63 32 65 24 73 3

74 22 74 2

78 39 78 2

79 29 79 2

80 2

81 1

82 3

82 27 82 37 82 36 83 2

84 ROW COL 4

84 6

84 22 84 36 84 37 84 1

87 28 88 2

89 7

89 4

90 1

91 15 95 24 95 30 95 26 99 to TXX-04157 Page 13 of 19 SG 3 Tubes with Percent Through Wall Indications ROW COL IND PER LOCN INCH1 48 34 PCT 11 C7 0.05 47 37 PCT 5

C5 0.48 48 40 PCT 5

C5

-0.28 46 41 PCT 14 C2 0.35 47 41 PCT 7

C3 0.37 48 41 PCT 32 C2 0.44 48 41 PCT 9

C3 0

48 42 PCT 22 C2 0.39 48 42 PCT 26 C3

-0.12 49 43 PCT 7

C7 0.05 46 45 PCT 7

C3 0.02 47 45 PCT 9

C2 0.28 47 45 PCT 5

C3 0.18 44 46 PCT 10 C2 0.14 44 46 PCT 9

C3 0.34 46 46 PCT 15 C3 0.25 43 48 PCT 8

C2 0.21 43 48 PCT 5

C3 0.28 46 50 PCT 9

C3 0.06 43 51 PCT 4

C3 0.3 43 52 PCT 6

C3 0.11 45 54 PCT 8

C2 0.24 45 54 PCT 32 C3 0.07 43 55 PCT 8

C2 0.05 45 55 PCT 8

C3 0.05 27 56 PCT 9

C3 0.38 ROW COL IND PER LOCN INCH1 20 59 PCT 8

C3 0.14 21 59 PCT 9

C3 0.54 36 59 PCT 14 C3 0.21 41 59 PCT 23 AV3 0

43 59 PCT 27 AV2

-0.27 43 59 PCT 34 AV3

-0.29 45 62 PCT 13 C3 0.11 45 70 PCT 8

C2 0.12 45 70 PCT 5

C2

-0.02 45 70 PCT 14 C3 0.32 45 70 PCT 9

C3 0.25 48 75 PCT 13 C5

-0.15 47 76 PCT 13 C2

-0.36 48 79 PCT 13 C2

-0.39 48 79 PCT 10 C5

-0.31 49 79 PCT 9

C7 0.14 46 80 PCT 4

C2

-0.39 48 80 PCT 7

C5

-0.28 47 81 PCT 5

C7

-0.37 48 81 PCT 12 C2 0.32 48 81 PCT 12 C3 0.28 48 81 PCT 16 C7 0.03 46 89 PCT 8

C2

-0.11 45 90 PCT 9

C2 0.17 45 91 PCT 6

C2 0.05 45 91 PCT 5

C3

-0.16

Attachment I to TXX-04157 Page l4of 19 SG 3 Tubes that were Removed from Service by Mechanical Plugging ROW COL IND LOCN INCH1 15 6

SVI CIO 0.26 25 7

DNT HI

-0.4 7

12 SAI H5 9.68 13 15 SCI HlI 3.94 35 20 SVI HTS 0.1 48 29 SAI AV2 0.03 5

31 SCI HTS

-0.02 6

32 RRT 8

34 PSC 36 35 RRT 31 44 RRT 48 49 RRT 8

50 PSC 11 51 RRT 5

52 SCI HIl 3.74 32 53 RRT 42 53 RRT 25 55 PVN HIl 0

18 56 PVN AV4 10.49 11 58 SAI HIl 40.65 20 63 PVN HlI 43.02 21 68 PVN HII 14.77 30 77 RRT 41 77 PSC ROW COL IND LOCN INCHI1 49 78 SAI AV4 3.33 1

85 RRT 2

85 RRT 4

85 PVN Hll 16.86 35 88 RRT 16 89 PSC 31 89 RRT 41 89 PSC 21 90 PSC

=

24 90 RRT 25 90 RRT 27 90 RRT 15 91 RRT 40 94 SCI HTS

-0.2 36 95 RRT 21 96 RRT 27 97 RRT 36 97 MCI HTS

-0.3 22 99 RRT 26 105 SCI HTS

-0.09 25 106 SCI HTS

-0.1 2

107 RRT 3

113 RRT

Attachment I to TXX-04157 Page 15 of 19 SG 3 Tubes that were Repaired by Sleeving at the Hot Leg Tubesheet ROW COL 7

9 10 10 9

12 2

14 1

18 19 20 20 20 2

21 9

22 23 22 2

23 3

25 27 26 23 27 3

29 2

30 10 30 1

34 2

34 3

34 22 34 2

35 27 36 2

37 3

37 22 37 24 39 2

40 3

40 4

40 4

41 3

43 2

44 23 45 28 45 26 47 28 47 ROW COL 37 47 2

48 24 48 30 48 24 49 24 50 30 50 31 50 6

51 24 51 11 52 25 52 29 52 32 54 7

55 3

59 28 61 2

62 29 63 32 65 1

66 26 67 28 69 42 71 33 72 24 73 3

74 22 74 23 74 2

78 39 78 2

79 5

79 29 79 2

80 26 80 42 80 ROW COL 2

81 1

82 3

82 10 82 27 82 37 82 42 82 36 83 2

84 4

84 6

84 12 84 22 84 36 84 37 84 19 85 4

86 34 86 1

87 3

87 12 88 28 88 2

89 7

89 4

90 1

91 2

91 2

92 38 92 2

93 7

93 17 93 23 93 2

94 12 94 14 94 19 94 ROW COL 3

95 15 95 17 95 20 95 24 95 28 95 30 95 25 96 26 96 21 97 25 97 29 97 32 97 10 98 13 98 19 98 25 98 26 99 7

100 10 100 22 100 16 101 4

103 7

103 7

104 8

104 19 104 20 104 8

105 11 105 13 105 22 105 4

108 9

108

Attachment I to TXX-04157 Page l6of 19 SG 4 Tubes that were Returned to Service by Plug Removal and Sleeve Installation ROW COL 2

10 1

17 37 37 1

39 1

42 2

43 2

48 31 50 1

54 31 54 31 55 1

56 40 1 60 31 61 19 62 35 62 3

63 33 64 ROW COL 2

66 37 66 5

67 21 67 31 67 32 67 34 68 1

69 4

69 6

69 30 71 2

72 2

74 5

74 32 74 1

76 9

76 20 77 ROW COL 32 77 34 77 2

78 20 78 38 78 2

79 33 79 34 79 4

80 18 82 30 82 35 82 6

84 18 84 23 85 2

87 3

88 6

89 ROW I COL 2

1 91 20 91 37 93 18 94 33 94 3

95 3

96 7

96 1

100 18 100 2

101 4

101 16 101 I1 102 7

105 4

106 4

107 4

110 SU 4 Tubes with Percent Through Wall Indical ROW COL IND PER LOCN INCH1 22 6

PCT 3

C2

-0.34 23 6

PCT 4

C4 0.34 30 10 PCT 4

C2

-0.28 33 13 PCT 4

C2

-0.2 33 13 PCT 4

C4 0.37 44 23 PCT 6

C2

-0.2 45 24 PCT 11 C2

-0.43 45 24 PCT 15 0C2 0.37 45 24 PCT 29 C3

-0.09 45 24 PCT 15 C5 0.2 12 26 PCT 9

C6

-0.37 46 26 PCT 6

C3

-0.17 48 32 PCT 7

C3

-0.2 48 32 PCT 9

C5 0.14 47 33 POT 4

C2

-0.2 48 33 POT 6

C3 0.11 47 34 PCT 4

C2

-0.26 47 34 PCT 10 C3

-0.31 47 34 PCT 6

C5

-0.12 48 34 PCT 8

C2

-0.17 48 34 PCT 20 C3 0.06 47 36 PCT 6

C3

-0.06 tions ROW COL IND PER LOCN INCH1 35 55 PCT 3

C2 0.31 45 55 PCT 14 C3

-0.2 25 56 PCT 7

C2 0

29 56 PCT 15 C3

-0.11 35 56 PCT 4

C2

-0.4 25 59 PCT 9

C3 0.17 30 59 PCT 7

C3 0.14 31 59 PCT 11 C3

-0.06 33 59 PCT 10 C2 0

33 59 PCT 22 C3 0

33 59 PCT 5

C4 0

21 60 PCT 7

C3 0

31 60 PCT 6

C3

-0.14 32 60 PCT 6

C3

-0.17 33 60 PCT 5

C2 0.03 33 60 PCT 13 C3 0

49 60 PCT 17 AV4

-0.29 29 61 PCT 6

C3

-0.09 42 61 PCT 7

C3

-0.09 45 61 PCT 5

C2

-0.17 45 61 PCT 8

C3 0.17 46 62 PCT 11 C3

-0.31

Attachment I to TXX-04157 Page 17 of 19 47 36 PCT 7

C5 0.26 48 36 PCT 6

C2

-0.34 46 38 PCT 4

C3

-0.2 46 39 PCT 5

C3

-0.12 48 39 PCT 11 C2 0.14 48 39 PCT 39 C3

-0.08 48 39 PCT 6

C5 0.26 48 41 PCT 8

C3 0.32 47 42 PCT 5

C3 0.31 48 42 PCT 10 C5

-0.4 47 43 PCT 6

C5

-0.11 45 44 PCT 6

C2

-0.03 45 44 PCT 10 C3 0.03 46 45 PCT 4

C5 0.11 47 45 PCT 8

C2 0.06 44 48 PCT 7

C2

-0.2 45 48 PCT 26 C3 0.06 47 48 PCT 26 C3

-0.2 47 48 PCT 13 C5 0.03 47 48 PCT 6

C7

-0.26 49 52 PCT 6

C7

-0.23 45 53 PCT 24 C3 0

36 54 PCT 3

C2 0.37 21 55 PCT 8

03 0

25 55 PCT 6

02

-0.37 29 55 PCT 5

02

-0.4 46 63 PCT 11 C3 0

45 64 PCT 22 C3 0.03 38 66 PCT 13 AV3 0.17 45 66 PCT 8

C2

-0.14 46 66 PCT 6

C3

-0.03 46 67 PCT 3

C2

-0.23 45 68 PCT 5

C2 0.34 45 68 PCT 7

C3

-0.2 47 70 PCT 5

C2

-0.29 48 73 PCT 11 C2 0.22 48 73 PCT 21 C3 0.14 47 74 PCT 3

C2

-0.34 47 74 PCT 6

C3 0

49 74 PCT 5

C5 0.11 46 76 PCT 6

C3 0.49 47 77 PCT 5

C3 0.25 35 78 PCT 4

C2

-0.43 48 83 PCT 5

C3

-0.37 16 86 PCT 7

C6 0.34 13 87 PCT 5

C6 0.38 14 88 PCT 7

C6 0.35 15 88 PCT 6

C6 0.37 16 88 PCT 6

C6 0.32 11 89 PCT 3

C5 0.55 13 89 PCT 7

C6 0.4 14 89 PCT 3

C6 0.36 to TXX-04157 Page 18 of 19 SG 4 Tubes that were Removed from Service by Mechanical Plugging ROW COL IND LOCN INCHI 21 11 PVN AVI 18.87 25 11 SVI C9 0.29 27 11 SVI C9 0.3 28 11 SVI C9 0.41 29 11 SVI C9 0.41 32 13 SVI H9 17.7 2

37 RRT 12 46 SCI HTS

-0.29 24 51 RRT 20 52 RRT 32 53 RRT 37 53 PSC 45 53 RRT 32 54 RRT 18 58 RRT I

35 65 PSC 29 67 PSC 27 68 PSC 13 71 SCI AVI 10.72 37 72 SVI H8 25.62 21 73 SVI C8 27.31 31 74 PSC ROW COL IND LOCN INCH1 33 77 PSC 39 78 PSC 30 80 MAI HTS

-0.3 37 81 SAI H5 0.15 15 82 SAI C7 16.24 16 83 PVN AVI 1.89 16 86 SVI C6 0.36 37 89 RRT 13 90 SO AVI 3.9 11 91 SCI HTS

-0.13 28 93 PSC 13 95 SCI HIl 14.21 27 95 PSC 29 95 RRT 14 96 SCI HTS

-0.16 24 97 PSC 3

98 SCI HTS

-0.16 3

104 SCI HTS

-0.08 20 107 SCI HTS

-0.34 24 107 SCI HTS

-0.14 14 108 PVN AV4 3.34

Attachment I to TXX-04157 Page 19 of 19 SG 4 Tubes that were Repaired by Sleeving at the Hot Leg Tubesheet ROW COL 2

10 1

17 4

23 17 24 20 24 6

26 1

33 8

34 37 37 1

39 31 40 1

42 13 42 2

43 11 43 6

45 12 45 2

48 31 50 6

51 8

52 18 52 1

54 31 54 41 54 31 55 1

56 35 56 40 60 5

61 31 61 33 61 19 62 35 62 3

63 5

64 ROW COL 31 64 33 64 37 65 39 65 2

66 37 66 5

67 21 67 31 67 32 67 34 67 39 67 5

68 7

68 34 68 1

69 4

69 6

69 30 71 2

72 5

72 31 72 2

74 5

74 11 74 32 74 39 75 1

76 2

76 7

76 9

76 10 76 20 77 23 77 32 77 34 77 ROW COL 2

78 9

78 20 78 34 78 38 78 40 78 2

79 6

79 33 79 34 79 4

80 5

80 9

80 2

82 18 82 30 82 35 82 7

83 6

84 8

84 11 84 13 84 18 84 26 84 6

85 23 85 2

87 3

88 21 88 1

89 6

89 8

89 10 89 13 89 5

90 9

90 ROW COL 2

91 6

91 10 91 20 91 2

92 6

92 37 93 18 94 33 94 3

95 3

96 7

96 4

98 17 98 29 98 I

99 6

99 1

100 2

100 3

100 6

100 18 100 2

101 4

101 16 101 1

102 2

102 4

103 13 103 5

104 9

104 7

105 2

106 4

106 4

107 4

110