August 16, 2004 Mr. J. A. Stall Senior Vice President, Nuclear and Chief Nuclear Officer Florida Power and Light Company P.O. Box 14000 Juno Beach, Florida 33408-0420
SUBJECT:
ST. LUCIE UNIT 2 - REVIEW OF THE ST. LUCIE UNIT 2 STEAM GENERATOR TUBE INSPECTION REPORTS FOR THE SPRING 2003 OUTAGE (TAC NO. MC1401)
Dear Mr. Stall:
By letters dated May 26, 2003, July 21, 2003, and November 21, 2003, Florida Power & Light Company (FPL) submitted reports summarizing the steam generator tube inspections performed during the spring 2003 refueling outage at St. Lucie Unit 2. In addition, FPL responded to questions raised by the Nuclear Regulatory Commission (NRC) staff on these reports in a letter dated June 25, 2004.
In the documents referenced above, FPL provided the scope, extent, methods, and results of their steam generator tube inspections. In addition, FPL described corrective actions (i.e., tube plugging or repair) taken in response to the inspection findings. Based on a review of the information provided, the NRC staff concludes that FPL provided the information required by St. Lucie Unit 2 Technical Specifications. In addition, the NRC staff concludes that there are no technical issues that warrant follow-up action at this time since the inspections appear to be consistent with the objective of detecting potential tube degradation and the inspection results appear to be consistent with industry-operating experience at similarly designed and operated units.
This completes NRC staffs efforts under TAC No. MC1401. If you have any questions regarding this matter, please contact me at 301-415-3974.
Sincerely,
/RA/
Brendan T. Moroney, Project Manager, Section 2 Project Directorate II Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No. 50-389 cc: See next page
Mr. J. A. Stall ST. LUCIE PLANT Florida Power and Light Company cc:
Senior Resident Inspector St. Lucie Plant U.S. Nuclear Regulatory Commission P.O. Box 6090 Jensen Beach, Florida 34957 Craig Fugate, Director Division of Emergency Preparedness Department of Community Affairs 2740 Centerview Drive Tallahassee, Florida 32399-2100 M. S. Ross, Managing Attorney Florida Power & Light Company P.O. Box 14000 Juno Beach, FL 33408-0420 Marjan Mashhadi, Senior Attorney Florida Power & Light Company 801 Pennsylvania Avenue, NW.
Suite 220 Washington, DC 20004 Mr. Douglas Anderson County Administrator St. Lucie County 2300 Virginia Avenue Fort Pierce, Florida 34982 Mr. William A. Passetti, Chief Department of Health Bureau of Radiation Control 2020 Capital Circle, SE, Bin #C21 Tallahassee, Florida 32399-1741 Mr. William Jefferson, Jr.
Site Vice President St. Lucie Nuclear Plant 6351 South Ocean Drive Jensen Beach, Florida 34957-2000 Mr. G. L. Johnston Plant General Manager St. Lucie Nuclear Plant 6351 South Ocean Drive Jensen Beach, Florida 34957 Mr. Terry Patterson Licensing Manager St. Lucie Nuclear Plant 6351 South Ocean Drive Jensen Beach, Florida 34957 David Moore, Vice President Nuclear Operations Support Florida Power and Light Company P.O. Box 14000 Juno Beach, FL 33408-0420 Mr. Rajiv S. Kundalkar Vice President - Nuclear Engineering Florida Power & Light Company P.O. Box 14000 Juno Beach, FL 33408-0420 Mr. J. Kammel Radiological Emergency Planning Administrator Department of Public Safety 6000 Southeast Tower Drive Stuart, Florida 34997
ML042290595 NRR-106 OFFICE PDII-2/PE PDII-2/PM PDII-2/LA EMCB-C/SC PDII-2/SC (A)
NAME JArroyo BMoroney BClayton LLund MMarshall DATE 8/11/04 8/11/04 8/11/04 by memo 07/31/2004 8/16/04