ML042290185

From kanterella
Jump to navigation Jump to search
Independent Spent Fuel Storage Installation Safety Analysis Report, Revision 19, Chapter 6, Waste Confinement & Management
ML042290185
Person / Time
Site: Robinson, 07200003  
Issue date: 08/10/2004
From:
Progress Energy Carolinas
To:
Office of Nuclear Material Safety and Safeguards, Office of Nuclear Reactor Regulation
References
-RFPFR
Download: ML042290185 (7)


Text

CHAPTER 6 WASTE CONFINEMENT AND MANAGEMENT

HBRSEP ISFSI SAR 6.1-1 6.0 WASTE CONFINEMENT AND MANAGEMENT 6.1 WASTE SOURCES No contaminated wastes are generated during the storage of irradiated fuel in the H. B.

Robinson (HBR) Independent Spent Fuel Storage Installation (ISFSI). The contaminated waste generated as a result of loading the spent fuel into the dry shielded canister (DSC) and into the IF-300 shipping container (see Chapter 5 for discussion of operations) is handled using existing H. B. Robinson Steam Electric Plant Unit No. 2 (HBR2) systems and procedures.

The small amounts of contaminated waste which may be generated consist of the spent fuel pool water and air and inert gas which are vented from the DSC and the cask during the drying operation. The handling of spent fuel and loading into the canisters occurs in the existing cask handling area within the Fuel Handling Building of HBR2.

HBRSEP ISFSI SAR 6.2-1 Revision No. 19 6.2 OFFGAS TREATMENT AND VENTILATION Small amounts of slightly contaminated air and inert gas may be generated during loading of the spent fuel into the dry shielded canister and then the cask. Since the spent fuel will be handled as if it is being prepared for offsite shipment using the IF-300, no new procedures are required. The HBR2 ventilation systems will be used to control any gaseous wastes generated. The ventilation systems are described in Chapter 9 of the UFSAR.

HBRSEP ISFSI SAR 6.3-1 Revision No. 19 6.3 LIQUID WASTE TREATMENT AND RETENTION The only liquid waste generated from the ISFSI results from loading the spent fuel assemblies into the dry shielded canister and into the IF-300 shipping container. This liquid waste is handled using existing HBR2 systems and procedures. The liquid waste system is described in Section 11.2 of the UFSAR.

HBRSEP ISFSI SAR 6.4-1 Revision No. 19 6.4 SOLID WASTES The ISFSI is not expected to generate any solid waste. Should any solid waste be generated, however, the existing HBR2 procedures will be used to process and dispose of the waste. Section 11.4 of the UFSAR describes the HBR2 solid waste processing system, the design basis, and an identification of the normal types of solid waste generated by HBR2 operations.

HBRSEP ISFSI SAR 6.5-1 Revision No. 19 6.5 RADIOLOGICAL IMPACT OF NORMAL OPERATIONS -

SUMMARY

The H. B. Robinson ISFSI is a passive and independent system which provides for the dry storage of irradiated fuel.

The ISFSI will not cause a significant radiological impact; the ISFSI has no requirement for radwaste or auxiliary systems for normal operation. Liquid and gaseous effluents utilized in the loading and handling of the Dry Shielded Canisters will be handled using the plant's existing process systems. There will be essentially no solid, liquid, or gaseous wastes generated during normal operation of the ISFSI.

The existing HBR2 health physics program and procedures are followed to maintain exposures ALARA during routine surveillances of the ISFSI.

HBR ISFSI SAR 6.R-1

REFERENCE:

CHAPTER 6 6.1 Carolina Power & Light Company, "H. B. Robinson Steam Electric Plant Unit No. 2 Updated Final Safety Analysis Report," Docket No. 50-261, License No. DPR-23.